Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.8 LAccepted-AOC | L1 | Accepted-AOC being L1 | |
| 2 | L2₹44.7 L+₹1.9 L (4.42%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹48.6 L+₹5.8 L (13.5%)Rejected-Finance | L3 | Rejected-Finance rejected being L3 |
Tender Value
Refer Docs
EMD Value
₹93,800
Closing Date
26 Feb 2021, 6:00 pmClosed
GE I R AND D East Bangalore
GE RD East Bangalore 93
SPECIAL REPAIRS TO DRAIN IN RESIDENTIAL AND TECHNICAL AREA AND PROVN OF FOOTPATH AND LIGHTING FOR ENTRANCE PARK IN RESIDENTIAL AREA AT DFRL MYSORE
2020_MES_368560_3
8969
Open Tender
Civil Works
Item Rate
270 days
GE I R AND D East Bangalore
D a (i) b (i)
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D East Bangalore
₹93,800
Yes
7 May 2021
5 Feb 2021
1 Mar 2021
5 Feb 2021
26 Feb 2021
13 Feb 2021
6 Feb 2021 - 11 Feb 2021
Amount
Demolition of brick work or stone masonary/boulder masonary, built in cement mortar including all quions, arches,pillars etc but excluding ashar facings, dressed stone work and precast article etc and depositing of debris out side MD Land all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15cm thickness (below or above ground level) and removal of debries to a distance not exceeding 100 Metre complete all as specified and as directed.
M&L Cement concrete in foundation filling and mass concrete in type D2, 1:4:8 (using 40 mm graded stone aggregate) complete all as specified and as directed
Material and labour for PCC 1:2:4, type B1 (Using 20mm graded stone aggregate) as in coping including necessary form work complete all as specified and as directed.
M & L for Walling of random rubble (Bangalore type), regular coursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and as directed
All as per item No 5 here-in-before, but except stone complete all as specified and as directed
Material and labour for brickwork with subclass 'B' bricks, straight or curved on plan exceeding 6m mean radius built in cement 1:6 complete all as specified and as directed.
M&L rendering 15 mm thick on stone masonry surfaces or surfaces other than fair faces of brick work in cement mortar 1: 6, surfaces to be finished even and smooth without using extra cement complete all as specified and as directed
M&L Reinforced cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate ) as in slab complete all as specified and as directed.
M&L TMT 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
M&L form work on rough finished sides of concrete sides and soffits (if any) and similar work of flat surfaces.
M&L PCC 1:2:4, type B-1 (using 20mm graded stone aggregate) as in band coping bed plate, benching etc including slightly rounded of chamfered angle, throating, etc complete all as specified and as directed.
M&L Reinforced cement concrete pipes of bore 200 mm class NP 2 with one collar per length of pipes laid on concrete bed complete all as specified and as directed.
M&L Cement concrete 1:4:8, type D2 (using 40mm graded stone aggregate) as in concrete bed to drain pipe 200mm bore including forming cradles after they are laid and tested complete.
M&L Salt glazed stone ware drain pipes 150mm bore class ‘A’ laid on concrete bed and jointed complete all as directed.
M&L Cement concrete 1:4:8, type D2 (using 40mm graded stone aggregate) as in concrete bed to drain pipe 150mm bore including packing under and haunching against the sides of pipes after they are laid down and tested complete
Cutting the exsiting hardstanding / metal road to faciliate for laying Hume pipe and making good portion to bring it original condition with PCC 1:4:8, type D2 (using 40mm graded stone aggregate) complete all as specified and as directed.
M&L Use and waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work of rough finished surface all as specified and as directed.
Surface dressing n.exc 15 cm deep and getting out in soft/loose soil complete all as specified and as directed.
M&L for hardcore of gauge not exceeding 63 mm of broken stone deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true srface complete all as specified and as directed.
M&L providing 60 MM thick precast cement concrete vibrating interlocking block (Heavy Duty) Manufactured from M-35 grade concrete , of approved colour and design/ pattern, including laid over a layer of 50mm thick sand cushion including filling the joints with fine sand complete all as specified and as directed
Excavation in trenches, n.exc 1.5 m in depth, for foundation etc or for shafts, wells, cesspits, manholes, pier holes, and for laying cable etc n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting put in soft/loose soil complete all as directed
Returning filling the excavated soil including spreding levelling watering and well ramming in layres not exceeding 15 cm thickness complete all as specified and as directed.
Removing of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at alevel not exceeding 1.5 mtr above the starting point all as specified.
M&L providing cement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregate) as in kerbs including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed
M&L applying two coat of synthetic enamel paint over a coat of primer including preparation of newly plastered concrete surfaces complete all as specified and as directed
M&L preparation of newly plastered wall surfaces and applying two coats of cement base paint over a coat of primer complete all as specified and as directed
S&F framed work such as grills, grtings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of watertanks and similar work conforming to Fe 290, Gde-E-165.
M&L Preperation of steel surfaces and applying two coat of synthetic enamel paint over a coat of red oxide primer primer over 10cm in width or girth complete all as specified and as directed
Material and labour for Sand cushioning to under ground cable providing with a layer 8cm thick before laying the cable and 15 cm thick after laying the cable complete all as specified and as directed Note: Punned thickness only will be measured for the purpose of payment.
Supply and laying well burnt brick sub class B of size 230mm x 115mm x 75mm in size, laid in trenches for cable protection complete all as specified and as directed.
M&L for Road cutting for laying of LT under Ground Cable/galvanised iron pipe complete all as specified
Supply and laying of under ground cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100Volts grade of cross section area 25sqmm X 3.5core in trenches / floor including connecting with suitable aluminium lugs / ferrules all as directed and specified by Engineer-in-charge
Supply and laying of under ground cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100Volts grade of cross section area 10sqmm X 4core in trenches / floor including connecting with suitable aluminium lugs / ferrules all as directed and specified by Engineer-in-charge
Supply and fixing of energy effficient LED bollard fitting of capacity 10Watts austhetically designed with symetrical light distribution IP 65 rated, spun aluminium with all accessories complete of make crompton Cat No. LBLTW-10-CDL or equivalent in havells/bajaj/philips, including making platform of size 2'X2'X2' complete all as directed by Engineer-in-Charge
Supply and fixing FRP junction box of size 250X200X100 mm of white colour hanged door type of locking arrangement, comprising aluminium bus bar of adequate capacity of 6Amps SP MCB on bakelite neutral of PVC insulated cable multistranded of size 2.5sqmm all as specified and as directed. Make Syntex/Anchor
Supply, install test and commissioning of LT feeder pillar box outdoor type, double door, made out of 3mm thick CRCA sheet duly painted with 2 coats of synthetic enamel paint over a coat of red oxide front and rear hinged door mounted on 50X50X6mm MS angle frame 60cms height erected in ground with PCC foundation 1:4:8 with 40mm stone aggregate suitable for 3phase 4 wire weather proof vermin cable gland and consisting of following :- a) MCCB 100 Amps 4way =1no. b) MCCB 415V 63 Amps =2no. (out going) c) MCB TPN 32 Amps =2nos. (outgoing)
Supply and laying GI tubing medium grade of size 40mm in trenches all as specified and as directed
Earthing complete with GI earth plate electrode 60cmx60xcmx6mm size buried directly in ground with bottom edge of the plate not less than 2.25 meters below normal ground level and connected to GI earth strip of size 32X6mm as earth strip by means of nuts bolts etc with and including necessary excavation, earth chamber with plain cement concrete 1:3:6 type C-1, necessary RCC chamber cover in cement concrete 1:2:4 with nominal reinforcement, funnel etc., all as shown in electrical plate No.3 of SSR Part I connected to earthing test point including testing on completion all as specified and as directed.
SAPTHAGIRI CONSTRUCTIONS
M/s H S VISWANATH CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .