Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC BALTIKURI INDUSTRIAL ESTATE PLOT NO A 01 DASNAGAR HOWRAH 711113 | HOWRAH | HOWRAH | WEST BENGAL | 711113 | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.6 L+₹56,390 (7.02%)Rejected-Finance 103 1A RAJA DINENDRA STREET KOLKATA 700006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L2 | Rejected-Finance L2 | |
| 3 | L3₹9.6 L+₹1.6 L (19.6%)Rejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
8 Sept 2025, 12:00 pmClosed
The Executive Engineer, Kolkata Electrical Div
The Executive Engineer Kolkata Electrical Division P.W.Dte. BlockI (1st Floor) Writers Buildings, Kolkata 700 001
SITC of Air Conditioning machines along with allied works related to Air conditioner at Parliamentary Affairs Department Writers Building Block G 1st Floor.
2025_WBPWD_888060_1
WBPWD/EE-KED/eNIQ-23Q/25-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Writers Buildings
Please refer Tender documents.
5 documents required · 5 mandatory
₹18,000
O/O The Executive Engineer Kolkata Electrical Divi
31 Oct 2025
6 Aug 2025
10 Sept 2025
6 Aug 2025
8 Sept 2025
14 Aug 2025
13 Aug 2025
Amount
SITC Microprocessr Controlled, DX Type ceiling suspended Ductable Air conditioner Unit with all necessary acessories for hanging Indoor& Outdoor unit as per site condition having following specification i) Refrigerent-R410A/R407C ii) Expansion Valve:Thermostatic/Electronics iii) Compressor :Single/Twin scroll Rotary with Fixed speed v) ODU: Outdoor Unit Air cooled Condenser unit With Copper coil with Aluminium fins having single compact ODU or multiple ODU unit vi) IDU: Indoor Unit having synthetic Filter and wireless/Wire Remote Vii) CFM: 400/Tr viii)Protection: Single Phase Preventer, phase reversal preventer, HP/LP cut Out. ix)Power sypply: 415+/- 10%, 50Hz x)Ambient temperature: 48°C +/- 5°C (Tollerance) Make: (Make:Hitachi/Daikin/ Blue Star/Voltas/carrier/Mitsubishi heavy / O- General) no extra shal be payable for refrigerant gas & transportation/shifting work.
Min BTU/Hr:19 KW (1 nos. compressor)
Fire Damper: Supplying, Fixing, testing and commissioning of Fusible link type fire damper.. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire in indoor motor and temperature rise above 62 degree centrigate (Make: Carryaire/ Dynacraft/ TSC/Ravistar/ Systemair/Jonson Control)
REFRIGERANT PIPING WITH INSULATION: Supply & Laying Hard / Soft drawn Copper Refrigeration pipe line for liquid and suction line suitable for R410A/R407C refrigerant & 19 mm thick Nitrile Rubber 'class O' Insulation tube with supports & brackets as per direction of EIC.
Liquid Line ( 5/8" dia) without rubber insulation (make: Rajco / Mandev / Royku)
Suction Line (7/8" dia) with 19 mm thick nitrile rubber insulation Al foil covered (make: Rajco / Mandev / Royku)
Supplying, fabrication & fixing M.S. Angle Frame for installation of 03 no Outdoor unit . the structure having 5 nos 50 x 50 x5 mm MS angle for main bottom support grouted on wall with total length 16' and in between main support 7 nos 25 x 5 mm ms strip . For railing vertical & horizontal support is made by 25 x 25 x 5 mm Angle for safety of maintenance , total length 35' ; including cutting holes , welding , painting and mending good damage as per EIC
DRAIN PIPE Supply and fixing of Drain piping by UPVC with 6mm thick nitrile rubber insulation and necessary quantities of supports, flanges, bends, elbows, fittings, nut-bolts, gaskets etc:
Supply and fixing of necessary electrical arrangements of Air Conditioning Units, PVC insulated FRLS grade Copper cable for connection betweeen indoor and outdoor units, 1.1 KV grade. 3 core x 2.5 mm² (Make- RR Kable / Finloex / Polycab).
Supply and fixing of necessary electrical arrangements of Air Conditioning Units, PVC insulated FRLS grade Copper cable for connection betweeen indoor and outdoor units, 1.1 KV grade. 4 core x 2.5 mm² (Make- RR Kable / Finloex / Polycab).
Fabrication , supply, Installation , testing & commissioning of following GSS(120 GSM) sheet conforming to IS:655 – 277 (SAIL/ TATA/ JINDAL or as per choice of EIC) rectangular/round duct complete with neoprene rubber gaskets, elbows, splitter supports, flanges, turning vanes for supply air / return air duct erected with supporting rods, fustners, nuts etc. - 24 SWG
Supplying and fixing of 13mm thickness duly laminated aluminium foil of mat fininshed closed cell Nitrile rubber (class ''O'') insulation ANTI MICROBIAL COATING type on duct after applying two coats of cold setting adhesive (The joints shall sealed with 50mm wide and 3 mm thick self afhesive nitrile rubber tape insulaton complete as per specifications and as required. for Duct (K-Flex / Amracell / Supreme / K-Flex)
ACOUSTIC INSULATION: Supplying & fixing of acoustic insulation inside ducting with 10mm thick open cell nitrile rubber(class O) of density 140Kg/cu.m-160 Kg/Cum insulation with bolts nuts GI washers etc as required. (Make - Armacell / K Flex / Supreme/ A-Flex)
Supply & Fixing of powder coated supply air GI volume control damper with diffusers Make - Premire /Systemair / Air Enterprise / Caryaire /Airmaster
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support - With 25x25x3mm angle iron support - 200x50x1.25mm (18SWG)
Supply & delivery of Inverter type Air- conditioner machine having cooling capacity not less than 5000W, ISEER Rating - 3.8-4.39 BEE rating not less than 3 star, Noise level not more than 50db, this split Air condition machine.fitted with Rotary compressor, LCD Remote and All other accessories suitable for Refrigerant- R410A/R32 Make:- O-General/ Mitsubishi Electric/ / Daikin/ Hitachi / Mitsubishi Heavy Industries as per EIC/ Authority.
Installation Testing & commissioning of the above Said Split Acs incl. Supply & fixing required Angle iron structure on wall for placing outdoor unit and mending Good the damages as per direction of EIC
S & Installation of Extra Add-on Items(above 3 mtr)- HVAC grade 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle, screws, insulation tape, fasner etc for above AC machines as per direction of EIC.
Supply & Laying 1.1KV grade 3 core 4 sqmm flexible copper cable with screw, saddle drill machine nut bolt etc all necy. items needed for connection.(from starter to AC outdoor connection)(Make: Havells/KEI/Polycab/Fenolex as per approved by EIC)
Supply & Laying 20mm hard PVC pipe(heavy type) for water discharge(Make: supreme )
S & F 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
S.R. REFRIGERATION AND APPLIANCES (BID ID -6907929)
Lyric International (BID ID -6850389)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .