Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 LAccepted-AOC CHOA HARIHARPARA MURSHIDABAD WB 742166 | CHOA | MURSHIDABAD | WEST BENGAL | 742166 | L1 | Accepted-AOC Quoting Lowest rate | |
| 2 | L2₹5.3 L+₹15,400 (2.99%)Rejected-Finance CHALITIA BERHAMPORE MURSHIDABAD | BERHAMPORE | MURSHIDABAD | WEST BENGAL | L2 | Rejected-Finance Quoting Higher Rate | |
| 3 | L3₹5.4 L+₹27,708 (5.39%)Rejected-Finance 159B M G ROAD HARIDEVPUR KOLKATA WEST BENGAL 700082 UDYAM WB 10 0018308 | KOLKATA | WEST BENGAL | 700082 | L3 | Rejected-Finance Quoting Higher Rate | |
| 4 | Rejected-Technical 12 1 FERRIGHAT ROAD P O BHATPARA DIST NORTH 24 PGS WEST BENGAL PIN 743123 | BHATPARA | NORTH 24 PARGANAS | WEST BENGAL | 743123 | - | Rejected-Technical Insufficient Documents |
| Sl No | Description | Qty | Unit | MONDAL ENTERPRISE L3 | G.M.N. ENGINEERING L2 | KHOKAN MONDAL L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation, Testing & Commissioning of Microprocessor controlled. IP Addressable Multi-sensor detector (VDS / UL /ERTL/ LPCB / FM approved) with inbuilt optical smoke Sensors and heat detector sensor with inbuilt short circuit fault Isolator as per NFPA style 7 wiring complete with base (Note Detectors without built-in fault isolator is also acceptable Provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. Thedetector should have 360 degree optical view with single/ multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors as per direction of EIC. (Make Esser by Honeywell / Secutron / Securiton/Johnson Control/ Cerberus Pro By Siemens /GST / Miacom) | 68 | NOS | 3,000 ₹2,04,000 | 2,900 ₹1,97,200 | 2,600 ₹1,76,800 Lowest |
| 2.00 | Supply, Installation, Testing & Commissioning of Microprocessor controlled IP Addressable Heat detector( VDS / UL/ ERTL / LPCB / FM approved ) with combination of fixed type & Rate of Rise of Temperature feature. Detector shall have minimum triggering temperature programmable from 60 deg. C to 880 degree. CC.., Having high lleevveel oof immunity to electromagnetic influences and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator as per direction of EIC.(Make Esser by Honeywell / Secutron / Securiton/Johnson Control/ Cerberus Pro By Siemens /GST / Miacom) | 4 | NOS | 2,700 ₹10,800 | 2,600 ₹10,400 Lowest | 2,600 ₹10,400 Lowest |
| 3.00 | Supply, Installation,Testing & Commisioning of IP Addressable Manual Call Point ( VDS / UL / ERTL / LPCB / FM approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required as per direction of EIC. (Make Esser by Honeywell / Secutron / Securiton/Johnson Control/ Cerberus Pro By Siemens /GST / Miacom) | 4 | NOS | 4,900 ₹19,600 | 4,800 ₹19,200 | 4,500 ₹18,000 Lowest |
| 4.00 | Supply, Installation, Testing & Commissioning of IP Addressable Loop Powered Hooter (sound output of minimum 80 db ) cum strobe (strength of iight 10 cd) complete with inbuilt short circuit fault isolator. (VDS / UL / ERTL / LPCB / FM approved) approved as per direction of EIC. (Make Esser by Honeywell / Secutron / Securiton/Johnson Control/ Cerberus Pro By Siemens /GST / Miacom) | 4 | NOS | 4,200 ₹16,800 | 4,100 ₹16,400 | 4,000 ₹16,000 Lowest |
| 5.00 | Supply, Installation, Testing & Commissioning of Loop Isolator Modules ( VDS / UL /ERTL/ LPCB / FM approved ) Loop Isolator can isolate the shorted circuit from the whole system to ensure normal operation of other devices and locate the devices in fault. After the short circuit fault is cleared, those devices will be re-introduced into the system with degree of protection IP 30 as per direction of EIC. (Make Esser by Honeywell / Secutron / Securiton/Johnson Control/ Cerberus Pro By Siemens /GST / Miacom) | 2 | NOS | 3,500 ₹7,000 | 3,400 ₹6,800 | 3,200 ₹6,400 Lowest |
| 6.00 | Supply, Installation, Testing & Commissioning of Microprocessor based addressable fully networkable 2 loop fire alarm control panel (VDS / UL/ERTL/ LPCB/ FM approved) suitable for the devices as stated in the previous items of this BOQ along with 20% spare capacity with each loop loading not exceeding 80 % of the full capacity of detectors and devices taken together, complying to IS 2189:2008 or its latest amendments, and with minimum 600 character alpha - numeric liquid crystal display with CAN networking,The panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches with help monitor module whenever any alarm is triggered. The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. | 1 | NOS | 1,44,000 ₹1,44,000 | 1,43,000 ₹1,43,000 Lowest | 1,50,000 ₹1,50,000 |
| 6.10The panel should have extra loop card slot for expansion of capacity twice. The panel shall have in built rectifier, provision for external & internal printer ( if required ), Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, inbuilt Surge protection facility, integral SMF lead acid batteries with sealed cells of 24V capable of running for 24 hours normal working and then be capable of operating the system for 60 minutes during Emergency condition, with integral battery charger complete in all respect as required. The FACP shall be capable of being networked (future expansion) with other similar FACP located at different part of the premises through single RS 485 modbus. The FACP shall have provision for interfacing with the public address system, remote computer and BMS interface. The system must be preloaded with licensed software as per direction of EIC. (Make Esser by Honeywell / Secutron / Securiton/Johnson Control/ Cerberus Pro By Siemens /GST / Miacom) | ||||||
| 6.20NOTE :- 1) The Fire Alarm system shall comply with latest requirements of -- (i) National Fire Protection Association (NFPA) standards, (ii) IS 2189 (iii) NFPA 7O National Electric Code, (iv) NFPA 72 National Fire Alarm & Signaling Code (v) Local Statutory Regulations , (vi) Manufacturer Recommendation vii) System should be integrated with the components like FACP, Detectors, MCP, Hooter, Monitor Module, Relay Module, etc. and all these components should be of same brand. | ||||||
| 6.30TESTS :- 1) The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2) Before energizing the cables and wires, inspection and check for correct connections, and test for short circuits, ground faults, continuity, and insulation and other tests as per applicable Indian/International standards must be done. | ||||||
| 7.00 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required as per GS. | 1,036 | RM | 90 ₹93,240 | 88 ₹91,168 Lowest | 88 ₹91,168 Lowest |
Tender Value
Refer Docs
EMD Value
₹12,000
Closing Date
13 Dec 2024, 11:00 amClosed
Superintending Engineer,Western El.Circle,PWD
Office of the Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103
Construction of Police Morgue at Prafulla Chandra Sen Government Medical College and Hospital, Arambagh in the district of Hooghly---- SITC of Fire Detection and Alram System
2024_WBPWD_774822_1
WBPWD/SEWEC /HED /NIQ-86/2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
45 days
Arambag
Please refer Tender documents.
5 documents required · 5 mandatory
₹12,000
Office of the Superintending Engineer, Western Ele
27 Jul 2026
27 Nov 2024
16 Dec 2024
27 Nov 2024
13 Dec 2024
30 Nov 2024
27 Nov 2024 - 29 Nov 2024
29 Nov 2024
Amount
Supply, Installation, Testing & Commissioning of Microprocessor controlled. IP Addressable Multi-sensor detector (VDS / UL /ERTL/ LPCB / FM approved) with inbuilt optical smoke Sensors and heat detector sensor with inbuilt short circuit fault Isolator as per NFPA style 7 wiring complete with base (Note Detectors without built-in fault isolator is also acceptable Provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. Thedetector should have 360 degree optical view with single/ multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors as per direction of EIC. (Make Esser by Honeywell / Secutron / Securiton/Johnson Control/ Cerberus Pro By Siemens /GST / Miacom)
Supply, Installation, Testing & Commissioning of Microprocessor controlled IP Addressable Heat detector( VDS / UL/ ERTL / LPCB / FM approved ) with combination of fixed type & Rate of Rise of Temperature feature. Detector shall have minimum triggering temperature programmable from 60 deg. C to 880 degree. CC.., Having high lleevveel oof immunity to electromagnetic influences and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator as per direction of EIC.(Make Esser by Honeywell / Secutron / Securiton/Johnson Control/ Cerberus Pro By Siemens /GST / Miacom)
Supply, Installation,Testing & Commisioning of IP Addressable Manual Call Point ( VDS / UL / ERTL / LPCB / FM approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required as per direction of EIC. (Make Esser by Honeywell / Secutron / Securiton/Johnson Control/ Cerberus Pro By Siemens /GST / Miacom)
Supply, Installation, Testing & Commissioning of IP Addressable Loop Powered Hooter (sound output of minimum 80 db ) cum strobe (strength of iight 10 cd) complete with inbuilt short circuit fault isolator. (VDS / UL / ERTL / LPCB / FM approved) approved as per direction of EIC. (Make Esser by Honeywell / Secutron / Securiton/Johnson Control/ Cerberus Pro By Siemens /GST / Miacom)
Supply, Installation, Testing & Commissioning of Loop Isolator Modules ( VDS / UL /ERTL/ LPCB / FM approved ) Loop Isolator can isolate the shorted circuit from the whole system to ensure normal operation of other devices and locate the devices in fault. After the short circuit fault is cleared, those devices will be re-introduced into the system with degree of protection IP 30 as per direction of EIC. (Make Esser by Honeywell / Secutron / Securiton/Johnson Control/ Cerberus Pro By Siemens /GST / Miacom)
Supply, Installation, Testing & Commissioning of Microprocessor based addressable fully networkable 2 loop fire alarm control panel (VDS / UL/ERTL/ LPCB/ FM approved) suitable for the devices as stated in the previous items of this BOQ along with 20% spare capacity with each loop loading not exceeding 80 % of the full capacity of detectors and devices taken together, complying to IS 2189:2008 or its latest amendments, and with minimum 600 character alpha - numeric liquid crystal display with CAN networking,The panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches with help monitor module whenever any alarm is triggered. The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards.
The panel should have extra loop card slot for expansion of capacity twice. The panel shall have in built rectifier, provision for external & internal printer ( if required ), Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, inbuilt Surge protection facility, integral SMF lead acid batteries with sealed cells of 24V capable of running for 24 hours normal working and then be capable of operating the system for 60 minutes during Emergency condition, with integral battery charger complete in all respect as required. The FACP shall be capable of being networked (future expansion) with other similar FACP located at different part of the premises through single RS 485 modbus. The FACP shall have provision for interfacing with the public address system, remote computer and BMS interface. The system must be preloaded with licensed software as per direction of EIC. (Make Esser by Honeywell / Secutron / Securiton/Johnson Control/ Cerberus Pro By Siemens /GST / Miacom)
NOTE :- 1) The Fire Alarm system shall comply with latest requirements of -- (i) National Fire Protection Association (NFPA) standards, (ii) IS 2189 (iii) NFPA 7O National Electric Code, (iv) NFPA 72 National Fire Alarm & Signaling Code (v) Local Statutory Regulations , (vi) Manufacturer Recommendation vii) System should be integrated with the components like FACP, Detectors, MCP, Hooter, Monitor Module, Relay Module, etc. and all these components should be of same brand.
TESTS :- 1) The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2) Before energizing the cables and wires, inspection and check for correct connections, and test for short circuits, ground faults, continuity, and insulation and other tests as per applicable Indian/International standards must be done.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required as per GS.
2 x 22/0.3 (1.5 sqmm) [1(a)/E-9]
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works as per GS.
20mm size [7(a)/E-16]
G.M.N. ENGINEERING (BID ID -5843943)
MONDAL ENTERPRISE (BID ID -5843087)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .