Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.0 LAdmitted-Finance | ₹45.0 L | L1 | Admitted-Finance |
| 2 | L2₹46.3 LAdmitted-Finance | ₹46.3 L | L2 | Admitted-Finance |
| 3 | L3₹47.6 LAdmitted-Finance | ₹47.6 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S R P ENTERPRISES L2 | SIDDHI ENTERPRISES L3 | P.S. ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00Safe carriage, loading-unloading with proper stacking of following material from ESC-Daliganj to Work Site/JE -Dump Store – | ||||||
| 1.01 | ST POLE 9/11 MT LONG | 50 | No. | 510 ₹25,500 | 525 ₹26,250 | 480 ₹24,000 |
| 1.02 | 11KV 3X70/120/185 SQ MM XLPE CABLE | 2,000 | Mtr | 10 ₹20,000 | 11 ₹22,000 | 9 ₹18,000 |
| 1.03 | 3.5X240/400/70 SQ MM PVC CABLE | 375 | Mtr | 5 ₹1,875 | 6 ₹2,250 | 4 ₹1,500 |
| 1.04 | ABC 3X120+1X95+1X16 | 500 | Mtr | 5 ₹2,500 | 6 ₹3,000 | 4 ₹2,000 |
| 1.05 | ABC 3X95+1X70+1X16 | 500 | Mtr | 5 ₹2,500 | 6 ₹3,000 | 4 ₹2,000 |
| 1.06 | ABC SINGLE PHASE (1X16+1X25) | 500 | Mtr | 5 ₹2,500 | 6 ₹3,000 | 4 ₹2,000 |
| 1.07 | 11/0.4 KV 250/400 KVA T/F | 25 | No. | 4,300 ₹1.1 L | 4,350 ₹1.1 L | 4,000 ₹1 L |
| 1.08 | 11/0.4 KV 100 KVA T/F | 25 | No | 3,200 ₹80,000 | 3,250 ₹81,250 | 3,000 ₹75,000 |
| 1.09 | 11/0.4 KV 63 KVA T/F | 12 | No | 1,700 ₹20,400 | 1,750 ₹21,000 | 1,500 ₹18,000 |
Tender Value
₹45 L
EMD Value
₹45,000
Closing Date
24 Jan 2026, 12:00 pmClosed
SE-Technical
Office of the SE-Technical, Central Zone, Lucknow
56/SE(T)/LCZ/2025-26
2026_MVVNL_1107072_1
56/SE(T)/LCZ/2025-26
Open Tender
Electrical Works
365 days
Executive Engineer 11 KV and LT Rajbhawan
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
Central bank of India
₹45,000
19 Feb 2026
19 Jan 2026
24 Jan 2026
19 Jan 2026
24 Jan 2026
19 Jan 2026
Safe carriage, loading-unloading with proper stacking of following material from ESC-Daliganj to Work Site/JE -Dump Store –
ST POLE 9/11 MT LONG
11KV 3X70/120/185 SQ MM XLPE CABLE
3.5X240/400/70 SQ MM PVC CABLE
ABC 3X120+1X95+1X16
ABC 3X95+1X70+1X16
ABC SINGLE PHASE (1X16+1X25)
11/0.4 KV 250/400 KVA T/F
11/0.4 KV 100 KVA T/F
11/0.4 KV 63 KVA T/F
11/0.4 KV 25 KVA T/F
GI WIRE 8 SWG
11 KV ST/TH C/J KIT 3X70/120/185 SQ MM
11KV END TERMINATION O/DOOR & I/DOOR 3X70/120/185 SQ MM
TOP CHANEL 100X50MM
M S EARTHING ROD 20X2500 MM
TOP CHANEL 125X65MM
11KV PIN INSULATOR
11KV PIN WITH NUT
STAY SET 16X1800 MM
STAY WIRE
M.S. ANGLE IRON 65X65X6MM
11 KV RMU
11 KV meter Cubicle
11 KV CT & PT Unit
Fabrication & erection of 11 KV cable exposure type double pole with the provission of cable with fixing of necesory clamps and other acessories like danger board, number plate, barbed wire,2 no. channels 100x50 mm (1600mm each),1 no.MS channel 100x50mm(3200mm in length) for supporting the hoisting of cable & poles.its jumpering by single core PVC aluminium cable with proper size Al.lug after making three phase busbar with help of 11 KV pin,pin insulator and PVC cable. (all material arranged by contractor except steel,pole,PVC aluminium cable & insulator).as per RESPO norms.
Fabrication & erection of S/S type double pole for 11KV line on 11 M long ST pole with fixing of necessary clamps & other acessories like 1 no. top channel 100×50 mm,2 no.MS angle 65x65x6mm,danger board,number plate,barbed wire,TPMO set & D.O.fuse set.
Double circuit cable laying in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m. the two cables should be seprated by a partition of single bricks (All the material required for laying will be supplied by the contractor except 11 KV XLPE cable)
S/C Cable laying in normal soil by digging of trench 900 mm deep, 500 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. (All the material required for laying will be supplied by the contractor except 11 KV XLPE cable)
Cable laying By dirll method Single circuit
Laying in RCC hume pipe with coller NP-4 200 mm dia single circuit.
In MS pipe 4" dia single circuit.
In HDPE pipe 160 mm dia
Laying of 11 KV XLPE Cable in HDPE pipe 160 mm dia by horizontal deep drilling method
Hoisting of 11KV XLPE cable3x70/120/185 sq mm on double pole with MS pipe 2 M long including its jumpering complete with clamps, nuts and bolts(all material arranged by contractor).
Digging of pit of size 3x2x1 mtr. for making straight through joint 11 KV size 3x/70185/120 sq mm work included boxing of pit by the help of sand, bricks and stone slab filling of soil leveling and ramming of the same .(S/Th Provided by department)
High Pressure testing of 11 KV XLPE cable. Testing equipment will be arranged by the contractor.
Placement of 11/0.4 KV T/Fs on S/S Type D/P & installation, commissioning of 400/250/100/63/25/ KVA T/F jumpering with the system ( All the required matrial for above job shall be provided by contractor except T/Fs)
Chemical Earthing system with outer pipe diameter 50mm, inner Strip 40x6, length 3000 mm. galvanization up to 200 micro, earthing pipe with crystalline conductive mixture filled inside the pipe with anti-corrosion & high conductive along with 50 Kg(As per required) of BFC which should be capable to reducing the soil resistively with good moisture retaining capacity.(Specification of chemical earthing and drawing is hereby enclosed). All material shall by supply by the contractor.
Laying of LT PVC Cable 3.5x240/3.5x400/3.5x70 sq mm single circuit in 900 mm deep, 500 mm wide including supply of required material as fine sand, 1st class bricks, stone slab (Except LT PVC cable)
Laying in RCC hume pipe with coller NP-4 200 mm dia single circuit.
In MS pipe 4" dia single circuit.
Construction of T/F plinth of size 2x2x1.5 m on a padding 0.25M deep in ground 1:5:10 cemend sand and brick ballast on the top of padding brick work Ist class brick of 0.95 mtr hight & 0.35 mtr wall will be constructed.Rest wall should be 0.23 mtr thick.brick work in ratio 1:4 cement & cores Sand in the hollow portion the sand should be fiilled from the ground level up to 15 centimeter below from the top of wall,Cement,sand & brick Ballasts should be filled up to 15 centimeter.Two no. of channel 100x50 in length 1500mm will be grouded.0.35 CM.RCC will be done with cores sand,cement and stone ballast in the ratio of 1:2:4.The t/fs plinth should be plastered on all sides 12mm thick in ratio 1:6 by cement and cores sand. (All the material will be arranged by the contractor.)
Placement of 11/0.4 KV T/Fs from dump place to newly constructed T/Fs plinth & installation,commissioning of 400/250/100/63/25 KVA T/Fs of T/F Plinth and including jumpering with the system ( All the required matrial for above job shall be provided by contractor except T/Fs)
Construction of retaining wall, fabrication & erection of Wire mesh fencing around Transformer and Distribution Pillar Box with retaining wall & 1 no. gate with locking arrangement made of MS Angle iron of size 50x50x6 mm jointed with nuts and bolts. The panel must be supported with MS Flat of size 50x6 mm. Wiremesh of size 10 SWG rectangle type, its painting as per norms of RESSPO. (All the material will be arranged by the contractor at his own cost).
Construction of massonary type Distribution Pillar box with first class brick ballast cement, coarse sand, local sand, brick ballast and MS Round bar of 10 mm dia including Straight MS Angle 50X50X6X750 mm- (All the material will be arranged by the contractor).
Suppy & fixing of henless fuse unit 500 amp 650 volts
Hoisting, winding and jumpering of of LT cable size 3.5x240 sq mm between LT distribution box/fuse unit & constructed overhead line with proper lugging and clamping
Providing earthing strip size 50x6mm and connecting from earthing pipe/m.s.earting rod to fuse unit/tronsformer body/neutral earthing (Earthing rod & earthing strip arranged by contractor).
Opening of consumer connection from existing line again reconnection with newly ercted L.T. distribution box/pillar box.
3 Phase (cable provided by contractor)
Single Phase (cable provided by contractor)
Fabrication & erection of single pole for LT line on 09 M long ST pole with fixing of necessary clamps & other acessories like clamp hook,dead/suspension clamp,neutral clamp,ABC pressure clamp (if required) and danger board with clamp.(all material arranged by contractor except steel & pole if required).
Stringing,Sagging,winding and jumpering of LT line with AB Cable (3x120+1x95+1x16) conductor as per RESSPO Norms.(AB Cable provided by deptt and balance material like holding clamp,eye hook,suspension clamp and dead end clamp arranged by contractor .)
Stringing,Sagging,winding and jumpering of LT line with AB Cable (3x95+1x70+1x16) conductor as per RESSPO Norms.(AB Cable provided by deptt and balance material like holding clamp,eye hook,suspension clamp and dead end clamp arranged by contractor .)
Stringing,Sagging,winding and jumpering of LT line with single phase AB Cable (1x16+1x25) conductor as per RESSPO Norms.(AB Cable provided by deptt and balance material like holding clamp,eye hook,suspension clamp and dead end clamp arranged by contractor .)
Supply and fixing of LT distribution box 3 phase 4 wire on existing wall/ Pole support with proper clamping of flexible pipe for casing of cable at suitable place for giving supply.
Nozeling, winding & grouting of stay set. (All the civil material & stay set will be arranged by the contractor except stay wire).
Fixing of earth rod (2500x20mm) as per norms. For earthing support of old existing poles of LT lines including 6 SWG GI/Earth wire. (All Materials provided by contractor)
Digging of Pit in kachcha/Pakka land in depth upto 1/6 length of Pole, Dragging of STP from near by place/Dump, Erection of Single pole along with stone pad in bottom with proper alignment of line for 11 KV line on 11 M long ST Pole and refilling with ramming of earth.
Grouting of pole in depth of 1/6 the length of pole in ratio 1:4:8 in cement sand and brick balast as per RESPO norms.
Construction of pole plinth 300mm x 450 mm above ground level in 1:2:4 in cement, coarse sand and stone gritt as per RESPO norms.
Painting of new erected ST pole with two coat of red oxide paint,PO red paint at top of pole 2 M & balance by two coats of best quality aluminium paint ISI of Burger/Nerolac/Asian mark as per norms.
Making of circuits
Taping of line
Installation and commissioning of CT/PT Metering unit including its connection in between TVM Meter and CT/PT Unit with required size of copper cable. Cable will be arranged by the contractor as his own cost.
Fixing of metering cubicle.
Installation of RMU
Fencing for RMU
Plinth for RMU
Supply & Fixing of CU L-Piece
Supply of copper stripe of size 50x50x6 mm
Supply & fixing of 11 KV TPMO
Dismentling of 11KV line, L.T. lines & distribution boxes and its dump at suitable place on site up to complition of work and its safe loading/unloading/weighing carriage from dump site to je"s store/ESC daliganj (Except broken PCC Pole).
ST Pole 11 Mt Long
Steel scrap of ST pole
11/.4 KV T/F 250/400/630 KVA
11/.4 KV T/F 25/63/100 KVA
ACSR mix conductor
Steel material
Tree branches cutting & chopping where required
All taxes as applicable shall be paid time to time extra
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
Doc56.pdf
Tender Documents • 0.81 MB
BOQ_2042779.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid