| 1 | L1₹22.4 LAccepted-AOC 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | L1 | Accepted-AOC Accepted being lowest bidder | |
| 2 | L2₹26.4 L+₹2.7 L (11.5%)Rejected-Finance | L2 | Rejected-Finance Rejected being not lowest bidder | |
| 3 | L3₹28.5 L+₹4.8 L (20.4%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L3 | Rejected-Finance Rejected being not lowest bidder | |
| 4 | L4₹28.5 L+₹4.8 L (20.5%)Rejected-Finance SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L4 | Rejected-Finance Rejected being not lowest bidder | |
| 5 | L5₹31.2 L+₹7.6 L (32.1%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L5 | Rejected-Finance Rejected being not lowest bidder |
Tender Value
₹34.2 L
EMD Value
₹68,500
Closing Date
7 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE KIRKEE
Headquarters CWE Kirkee, Military Engineer Services, Range Hills Road, Kirkee, Pune-411003
REPAIR MAINTENANCE OF AMF PANEL INCLUDING HT/LT ELECTRIC SUPPLY SYSTEM WITH REWINDING AND MAINTENANCE PIPELINE AND ITS CONNECTED WORK AT INSP ORG UNDER GE (MH AND RH) KIRKEE
2022_MES_503795_2
CWE/KKE/TOKEN-45 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KIRKEE
As per tender
5 documents required · 5 mandatory
₹500
Yes
GE MH AND RH KIRKEE
₹68,500
Yes
9 Apr 2022
21 Feb 2022
9 Mar 2022
21 Feb 2022
7 Mar 2022
22 Feb 2022
60 days
Amount
Excavation in trenches n. exc 1.5 m wide and n. exc 1.5 mtr depth n exc 10 sqm on plan ffor taking out cable etc for repairs / laying cables etc and getting out in hard/dense soil complete all as specified and directed by Engr-in-charge.
Excavation in trenches n. exc 1.5 m wide and n. exc 1.5 mtr depth n exc 10 sqm on plan ffor taking out cable etc for repairs / laying cables etc and getting out in soft/loose soil complete all as specified and directed by Engr-in-charge.
Excavation in trenches n. exc 1.5 m wide and n. exc 1.5 mtr depth n exc 10 sqm on plan ffor taking out cable etc for repairs / laying cables etc and getting out in soft / disintegrated rock complete all as specified and directed by Engr-in-charge.
Returning filling in including spreading, levelling, watering and well ramming in layers n.exc. 25cm in soils complete all as specified and directed by Engr-in-charge.
Removing excavated material( soil) to a distance not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and as directed.
Supply and spread Riddled earth for cable cushioning complete all as specified and directed by Engr-in-charge. Note:-Thickness of Riddled earth cushioning shall be measured after punning
Supply and laying reinforced precast concrete cable cover class HV, type 1, flat size 300 mm x 180 mm x 40 mm size for cable protection complete all as specified and as directed.
M&L for old size brick Class 'B' protection for Under ground cable complete all as specified and directed by Engr-in-charge.
Taking down burnt bricks / PCC covers of any size and relaying the same after laying of cable complete all as specified and directed by Engr-in-charge.
Taking down unserviceable HT 11 KV/ 22 KV cable of any size and description complete all as specified and directed by Engr-in-charge.
Relaying only the serviceble HT 11 KV/ 22 KV cable of any size and description obtained from item No 10 above after jointing, etc complete all as specified and directed by Engr-in-charge.
Supply, laying & testing XLPE insulated, PVC sheathed, bedded, galvanized steel strip (heavy duty) amoured electric aluminium conductor cable 11000 volts (earthed) grade of cross sectional area 95 Sqmm 3 core including disconnecting and removing old unserviceable cable and bricks complete all as specified and directed by Engr-in-charge.
Supply, laying & testing XLPE insulated, PVC sheathed, bedded, galvanized steel strip (heavy duty) amoured electric aluminium conductor cable 22000 volts (earthed) grade of cross sectional area 95 Sqmm 3 core including disconnecting and removing old unserviceable cable and bricks complete all as specified and directed by Engr-in-charge.
M & L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm including taking down old cable joint kit complete all as specified and directed by Engr-in-charge.
M & L for cable jointing kit for 22000 V (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm including taking down old cable joint kit complete all as specified and directed by Engr-in-charge.
M & L for cable jointing kit for 22000 V (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 Sqmm including taking down old cable joint kit complete all as specified and directed by Engr-in-charge.
M & L for heat shrinkable HT 22 KV (earthed) straight through joint cable kit suitable for aluminium conductor cable of size 3 core 185 Sqmm complete all as specified and directed by Engr-in-charge.
M & L for heat shrinkable HT 22 KV (earthed) straight through joint cable kit suitable for aluminium conductor cable of size 3 core 95 Sqmm complete all as specified and directed by Engr-in-charge.
M&L for cable route indicator made out of PCC 1:3:6 of size 300x100mm, 450mm above ground level finished even and fair with 10mm thick plaster 1.6 ambeded upto 600mm below ground level of size 300x300mm and marked/ written for HT 11KV including indicating direction with and including painting with two coats of synthetic enamel paint over a coat of primer to exposed surfaces complete all as specified and directed by the Engineer-in-charge.
Disconnecting the transformer indoor/ out door from HT (22/11 KV) / LT(440 volt) side at site dismantling carefully and removing primary and secondary terminals, top cover with conservator tank, neutral earth strip and draining out transformer oil to the required level and storing carefully in cleaned containers, cleaning of terminals, inspection of core, supply and replacing 5 mm thick rubberised cork sheet gasket for tank top cover and reassembling the complete dismantled items, reconnecting the HT/ LT supply cable ends at the site for the following transformers complete all as specified and directed by Engr-in-charge.
a) Transformer capacity 100KVA to 250 KVA
b) Transformer capacity 300KVA to 500 KVA
Filteration of transformer oil of transformer installed at various locations out door/in door transformer to achieve electric strength of 40 KV for 1 minute at 4mm gap as per relevant IS with portable filteration plant, testing of oil for di electric strength before and after filteration shall be conducted all as directed by the Engineer in Charge Note : Test results after filteration shall be produced on completion.
Supply and topping up new transformer oil into the conservator tank/body tank of the transformer at various location complete all as directed by the Engineer-in-charge. (Make : Power Oil or its equivalent as approved by GE) Note : The transformer oil for topping up shall be with di-electric strength of 40KV
Material and Labour for rewinding of HT /LT windings of transformer of capacity 200 KVA, winding the defective coils with approved quality copper wire as per IS of same gauge and existing size together with new insulation materials, bracings the terminals before placing into the tranformer and assembling the HT / LT coil with new insulation between core and LT coil all as required and fitting the coils in the chamber, testing and commisioning the transformer after providing necessary connections complete including transportation to workshop all as directed.
Material & Labour for replacing silica gel breather for the following sizes of transformers:-
100 to 200 KVA
300 to 500 KVA
Material and Labour for shifting of transformer of any capacity from one area to another area and placing in position and making all conections including removing and depositing the old transformer to store yard carefully and properly testing and commisioning transformer complete all as specified and directed by Engr-in-charge.
Taking out old unserviceable deffective HT bushings from transformers and material and labour for new porcelain bushing with brass stud, nuts and washers, connecting to the winding testing and commissioning the transformer of capacity 100 to 200 KVA complete all as specified and directed by Engr-in-charge.
Taking out old unserviceable deffective HT bushings from transformers and material and labour for new porcelain bushing with brass stud, nuts and washers, connecting to the winding testing and commissioning the transformer of capacity 300 to 500 KVA complete all as specified and directed by Engr-in-charge.
Taking out old unserviceable deffective LT bushings from transformers and material and labour for new porcelain bushing with brass stud, nuts and washers, connecting to the winding testing and commissioning the transformer of capacity 100 to 200 KVA complete all as specified and directed by Engr-in-charge.
Taking out old unserviceable deffective LT bushings from transformers and material and labour for new porcelain bushing with brass stud, nuts and washers, connecting to the winding testing and commissioning the transformer of capacity 300 to 500 KVA complete all as specified and directed by Engr-in-charge.
M&L for switch air-break gang operated horizontal/vertical type single break, 11000 volts grade, triple pole, mechanically operated mounted on 9 insulator and steel frame, with operating mechanism worked from ground level, for current rating 400 amps capacity including taking down old AB switch complete all as specified and directed by Engr-in-charge. ( Make: Pactil /Jaipuria Brothers / MEC Trivandrum)
11000 volts grade
22000volt grade
M&L for Drop out fuse suitable for 11 KV current rating 25 to 50 Amps including taking down old HT Drop out fuse units complete all as specified and directed by Engr-in-charge ( Make: Jaipuriya Brothers / Jayshree / Mysore)
M&L for Drop out fuse suitable for 22 KV , horn gap fuse type , current rating 25 to 50 Amps including taking down old HT Drop out fuse units complete all as specified and directed by Engr-in-charge ( Make:Jaipuriya Brothers / Jayshree / Mysore)
M&L for lightning arrester high tension expulsion type complete with all fittings transmission class, discharge capacity 30 Kilo amps suitable for 11000 Volts supply including taking down old lightning arresters complete all as directed ( Make: Jaipuriya Brothers/ Jayshree / Mysore/Areva)
-ditto- all as per item No 33 above for 22 KV/33 KV
Supply and replacement of pin type porcelain vitreous white/ brown insulator of size 150 mm height, 150 mm dia 11000 volts grade incl one galvanised mild steel spindle, two galvanised washers and one galvanised iron nut complete all as specified and directed by Engr-in-charge. (Make: Jayshree / Mysore porceleain / Jaipuria / BHEL / Southern insulator / WS insulators)
-ditto- all as per item No36 above for 22 KV
Supply and replacement of disc type porcelain vitreous 145 mm height and 255 mm dia ball and socket type white, brown or green for working pressure 11000 volts including mild steel straps of size 38 x 5 with 20mm dia bolts including spendal all as directed (Make: Jayshree /Mysore porcelain / Jaipuria / BHEL / Southern insulators / WS insulator)
-ditto- all as per item No-37 above for 22 KV
Taking down old unserviceable earthing and M & L for earthing complete withGI earth plate electrode of size 600mm x600mmx 3.15 mm thick burried directly under ground vertically to a depth not less than 2.25meter below ground level with top edge of the plate at a depth not less than 1.5 m below ground level connected to and including GI strip 32 x 6 mm, by means of bolts, nuts, check nuts and washeres made out of GI including protection pipe GI light grade 40 mm size and watering pipe 20 mm dia GI medium grade all as shown on plate No 3 of SSR Part-I, connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on complete all as specified and directed by Engr-in-charge
Supply and replace MCCBs 3 pole 63 Amps, 415 Volts, 16 KA adjustable type complete all as specified and directed by Engr-in-charge
Supply and replace MCCBs 3 pole 125 Amps, 415 Volts, 16 KA adjustable type complete all as specified and directed by Engr-in-charge
Supply and replace MCCBs 4 pole 160 Amps, 415 Volts, 16 KA adjustable type all as specified
Supply and replace MCCBs 4 pole 200Amps, 415 Volts, 25 KA adjustable type complete all as specified and directed by Engr-in-charge
Supply and replace MCCBs 4 pole 250 Amps 4 pole 36 KA complete all as specified and directed by Engr-in-charge
M & L for detect HT 11/22 KV cable fault and LT cable fault for various size cable of 24 hrs x 7 days i.e entire contract day with technician around the clock on CQA (ME) & CQA (EE), CQA(FE), NBC, and CQA residential areas detect the cable fault and necessary excavation of soil and refilling the soil, joint the faulty cable with new straight through joint kit, after jointing, testing, and charging of HT / LT cable all as specified and directed by Engr-in-Charge. (Note: (i) Cable joint required size measured and paid separately (ii) Each job considered cable fault locator use in one day)
M&L for cleaning of MES electric supply installations/campus by surface dressing or trimming of natural ground to remove small unequalities (including removing vegetation/ shrubs/brush wood/under growth) and carrying away the rubbish to a distance of not exc 50 mtr away complete for the various sub stations. incl spray of herbsite
Taking down unserviceable LT UG cable of any size upto 240 Sqmm carefully from trenches/poles/ducts/LT panels, OH conductors and relay at different locations all as specified and directed by Engr-in-Charge.
Re-laying only the serviceable cable of any size and description obtained from Item No-47 above joining etc all as directed. Note: (i) While re-laying retrived sand will be re-used without any extra cost. (ii) Re-trived Bricks and PCC cover paid as laying only rate. (iii) Earth works are meaured and paid in Item No-01 to 05 like excavation, re-laying bricks, Returning & Refilling, Removal.
Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, insulated, armoured heavy duty electric XLPE cable with multistranded aluminium conductor, 1100 volts grade, cross-sectional area of size 25 sqmm 3.5 core with all as specified and directed. by Engr-in-charge
,-ditto- all as per item No. 49 here-in-before but 35sqmm 3.5 core complete all as specified and directed by Engr-in-charge
-ditto- all as per item No. 47 here-in-before but 50sqmm 3.5 core complete all as specified and directed by Engr-in-charge
-ditto- all as per item No. 49 here-in-before but 70sqmm 3.5 core complete all as specified and directed by Engr-in-charge
-ditto- all as per item No. 49 here-in-before but 95sqmm 3.5 core complete all as specified and directed by Engr-in-charge
-ditto- all as per item No. 49 here-in-before but 120sqmm 3.5 core complete all as specified and directed by Engr-in-charge
-ditto- all as per item No. 49 here-in-before but 185 sqmm 3.5 core complete all as specified
-ditto- all as per item No. 49 here-in-before but 240 sqmm 3.5 core complete all as specified and directed by Engr-in-charge
-ditto- all as per item No. 49 here-in-before but 16 sqmm 4 core complete all as specified and directed by Engr-in-charge
M&L for Painting on four pole structure with two coat of aluminum paint over red oxide paint after preparation of old surfaces , complete as existing complete all as specified and directed by Engr in charge .
supply and connect, testing, commissioning of LT capacitor 3 to 15 KVAR including capacitor duty contactor of suitable capacity of on existing APFC panel and necessary panel wiring for stud mounting cylindrical type having very good KVAR to volume ratio conform to IEC 60831-1 & 2 IS 13340 of range single unit of 5/6 KVAR voltage range 220 V to 440Volt of Heavy duty for non-linear loads up to 440 V using state of art metalisation process for MPP film with heavy edge self healing property, low energy consumption, soft biodegradable resin as impregant safety device in the form of pressure sensitive(over pressure) mechanical interrupter, Temp class 10/D, 3 phase, 50-60 Hz, IR-6.56 amps, after fixing of capacitor testing the PF value achive 1.000 all as directed and satisfied by Engr-in-Charege Make: For capacitor L & T Cat No: LTCCN 56B2 or equivalent make of Legrand/Schneider & For contactor Make L & T cat No: CS96127 or equivaltnt make of Legrand /Schneider
-ditto- all as per item No 59 Above but of capacity 20 to 25 KVAR Capacitor all as specified and as directed.
Taking down old unserviceable CT coil and S & F CT coil of CT Ratio --/5A as per site requirement all as directed by Engr-in-Charge.
Supply and laying GI tubing light grade 40mm bore, ISI marked, for cable protection incl taking down old protection pipe
Supply and laying GI tubing light grade 50mm bore, ISI marked, for cable protection incl taking down old protection pipe complete all as specified and as directed.
Supply and laying GI tubing light grade 80mm bore, ISI marked, for cable protection. incl taking down old protection pipe complete all as specified and directed by Engr-in-charge
M&L for road cutting and making good with PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) of 150mm X 100mm inrespect of width and thickness complete all as directed by Enger -in- charge.
Decarbonizing of LT indoor/outdoor Panel/feeder pillar box any type replacing unserviceable control wiring for panle, including cleaning of bus bar and insulated with suitable colour code , indicator lamps, removing unserviceable Ammeter, Volt meter , replace with new multifunction meter, painting inside and outside of the panel with enamel paint, fixing proper hanging front and rear openings, welding of hinges including using extra sheets replacing burnt thimbles with new thimbles re-fixing of required size, incluidng re-connecting the LT cables and testing complete all as specified and directed by Engr -in- charge.
Calibration of APFC panel by cleaning, tightning of connections, setting programme,checking of CT, Control wiring including replacement of unserviceable items like indication lamps, MCB's, control wires and testing the panel to acheive power factor of 0.999(lag) all as specified and as direced by Engr-in-Charge.
Supply and replace power factor controllers 8 steps, 415 volt, AC, 50 HZ power supply and replacing old unserviceable controllers including suitable wiring all as directed and satisfied by Engr-in-Charge. Make: L &T Cat No ETACONM008R or equivalent make of Scheider, EPCOS
Supply and fix lightning arresters set of three expulsion type 11000V, 65kilo Amp complete with all fitting , transmission class with discharge capacity 65kilo Amp mounting on strcture with all neccessory items required at site all as specified and directed by Engr in Charge
Disconnecting incoming and outgoing cable/busbar connections (as required), taking out the draw out type air circuit breaker of any make, type from the cradel for overhauling & servicing through OEM of 3/4 pol, 415 Volts, AC, current rating 800 A-1000 Amps by carrying out the following all as specified and as directed. (a) Cleaning of dust, spider web, foreign particles etc. (ii) cleaning of various parts with CRC-2-26 (iii) Replacement of damaged parts. (iv) Checking, setting and adjusting the spring charging mechanism closing and tripping mechanism operation auxilary switch contacts. (v) Checking of breaker operation in isloating/test and service position. Note: 1. The contactor has to replace minor spares like spring washers, locking pin, circlip, spring, nut-bolts etc. 2. The servicing/overhauling of breaker is to be carried out at site. 3. Major spares required to be replace during servicing will be measured and paid under relevant items as specified in the schedule.
Supply and replace under volt trip device for 240 V, AC for 800-1000 Amps complete all as specified and directed by Engr-in-charge
Supply and replace under volt trip device 440 V AC for 1000 Amps complete all as specified and directed by Engr-in-charge
Supply and replace shunt Trip coil 240 V AC for 1000 Amps ACB. complete all as specified and directed by Engr-in-charge
Supply and replace closing coil 240 V for 1000 Amps ACB. complete all as specified and directed by Engr-in-charge.
Supply and replace Spring closing Motor 240 V AC for 1000 Amps ACB complete all as specified and directed by Engr-in-charge.
Supply and replace spring charge indicator SCIS-M for 1000 Amps ACBcomplete all as specified and directed by Engr-in-charge.
Supply and replace mechanical interlocking (D/O-Vertical/Horizontal) system for 1000 A ACB complete all as specified and directed by Engr-in-charge. Make: CG
Supply and replace Arc contacts, for 1000 Amps ACB complete all as specified and directed by Engr-in-charge
Supply and triping indicating switch for ACB 1000 Amps. complete all as specified and directed by Engr-in-charge.
Supply and replace moving contact Assembly for 1000 amps ACBcomplete all as specified and directed by Engr-in-charge.
Supply and replace under volt release (UVR) 220/415 Volt AC for ACB 1000 Ampscomplete all as specified and directed by Engr-in-charge.
Supply and replace Earth fault relaease for ACB 1000 Amps. complete all as specified and directed by Engr-in-charge.
Supply and replace shunt release (SR) 240/415 V AC, complete all as specified and directed by Engr-in-charge
M & L for jointing the LT cable with heat shrinkable straight through join, by disconnecting the cable ends, removing the damaged portions of cable, by suitable means, joining by ferrules etc and testing for LT 1100 V cable of size 3.5/4 core 6-16 Sqmm all as directed and specified.
M & L for jointing the LT cable with heat shrinkable straight through join, by disconnecting the cable ends, removing the damaged portions of cable, by suitable means, joining by ferrules etc and testing for LT 1100 V cable of size 3.5/4 core 25-50 Sqmm complete all as specified and directed by Engr-in-charge
M & L for jointing the LT cable with heat shrinkable straight through join, by disconnecting the cable ends, removing the damaged portions of cable, by suitable means, joining by ferrules etc and testing for LT 1100 V cable of size 3.5/4 core 70-120 Sqmm complete all as specified and directed by Engr-in-charge
Supply and joint heat shrinkable type straight through joints(Tubular sleeve version) for joint LT 1100 volts grade 150-185 sqmm, 3/3.5/4 core, make-3M, Raychem RPG, M-Seal (Note: Necessary excavation, returning filling will be measured and paid separately)
Supply and joint heat shrinkable type straight through joints(Tubular sleeve version) for joint LT 1100 volts grade 240-300 sqmm, 3/3.5/4 core, make-3M, Raychem RPG, M-Seal (Note: Necessary excavation, returning filling will be measured and paid separately)
M&L for Spray Painting on panel/ steel surface with one coat of synthetic enamel paint of same colour including preparation of old surfaces complete as existing complete all as specified and directed by Engr in charge .
M&L for transformer Painting with one coat of synthetic enamel paint of same colour including preparation of old surfaces complete includuing writing the MES no in bold letter complete all as specified and directed by Engr in charge .
M&L for Painting on two pole structure with two coat of aluminum paint over red oxide paint after preparation of old surfaces , complete as existing complete all as specified and directed by Engr in charge .
Star Electrical
metro electrical services
Rama Electricals
ONKAR ELECTRIC AND GENERAL STORE
SBS Enterprises
SHRI SWAPNAYOG ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .