| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹17.8 L+₹2.1 L (13.7%)Rejected-Finance | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 3 | L3₹19.2 L+₹3.5 L (22.6%)Rejected-Finance NO 12 5TH B CROSS SHARADAMBA NAGAR M E S ROAD BANGALORE 560013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 4 | L4₹20.1 L+₹4.4 L (28.2%)Rejected-Finance NO 131 5TH CROSS PASCHIM COUNTY MEDARAHALLI CHIKKABANAVRA POST BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L4 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
₹19.5 L
EMD Value
₹39,000
Closing Date
27 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
8453E8PROVN OF CERTAIN E AND M MINOR REVENUE AND LBW WORKS IN WEST AREA UNDER GE M AF JALAHALLI BANGALORE
2020_MES_365790_1
8503E8
Open Tender
Electrical and Maintenance Works
Item Rate
182 days
Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Garrison Engineer M AF Jalahalli
₹39,000
9 Dec 2020
31 Jul 2020
29 Aug 2020
1 Aug 2020
27 Aug 2020
14 Aug 2020
1 Aug 2020 - 7 Aug 2020
60 days
Amount
Material and labour for surface Point wiring using approved colour coding as per IS ( Red, black and green for single phase circuit ), with 1.5 Sq mm cross sectional area,single core, multi stranded copper conductor (FRLS) PVC insulated and unsheathed electrical cable ISI Marked and including medium grade,PVC conduit of dia not less than 20 mm and conduit accessories concealed in wall/roof/floor (expept on RCC ceilling and on roof trusses where conduit shall be on surface) ISI marked conduit and conduit accessories with mild steel/pressed steel sunkun boxes (with earth dolly) dully painted with two coats of black bituminous paint over a coat of red oxide primer externally,covered with 3 mm thick plastic laminated sheet cover for fixing of switches,socktes etc and making good the disturbed surface with cement mortor plastering and matching with existing surface including PVC insulated multi-stranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly for exhaust fan point controlled by one way one switch 5 Amp complete all as specified. Note - 1.Switch piono type to be measured and paid separately in respective items .
All as per Item No-01 here in before but for bell point controlled by one way bell push switch SP 5 Amps, 240 V complete all as specified. Note - 1.Bell push to be measured and paid separately in respective items.
All as per Item No-01 here in before but for 05 Amp independent socket point controlled by one way SP 05 amp Piano type switch 240 V complete all as specified. Note - 1.Piano type switch 5 Ampand socket 05 Amp to be measured and paid separately in respective items.
Supply and fixing switch piano flush type single pole one way, 5 Amps 240 V grade ISI marked complete.
Supply and fixing socket outlet multipurpose , 5 pin, 6 Amps 240 volts complete all as specified and directed.
Supply and fixing bell push switch 5 Amps, 240 volt, flush type ISI marked complete all as specified.
Supply and fixing ceiling rose surface backlite 65 x 20 mm size three terminal ISI marked complete.
Supply and fixing ,testing commisioning heavy duty Exhaust fan of size 300 mm sweep, 6 pole,900 rpm +-5%,230 volts 50 Hz,0.9 power factor ,single phase,four blade, mounting on ms sheet frame Motor insulation class - E with MS shaft comply with (1.70 to 2 mfd) capacitor mounted on fan motor back over suitable clamp and body finishing with grey supper enamalled with primer coat including MS frame with flexible rubber pad for redude of motor vibrations and provide electic connection ceilling rose to fan using three core copper cable of 1.00 sq mm drawn through pvc flexible pipe 15 mm dia complete all as specified .Make- Havells/Usha/CG Note - Making hole in any type wall (i.e Brick /stone masonary ) of appropriate size to fix the exhaust fan 300 mm and grouting of Bolts, giving suitable shape and making good the disturbed surface with cement mortor plastering, applying white wash and matching with existing surface including in item rates.
Material and labour for Louver made out of aluminium in suitable size for Exhaust fan 300 mm in round shape ,weather proof, corrosion resistant, in silver colour including mounting frame of louvers in same material fixed to any type wall of kitchen/toilet at ground floor,1st floor and 2nd floor complete all as specified and directed. Note - The tools required for fixing of louver at ground floor, 1st floor and 2nd floor of building shall be including in qouted rates of items.
Supply and fixing electric bell AC, ding-dong type, 230 Volt, single pole including PVC mounting bracket (for Bell fixing) including screw as per required complete all as specified
Supply and fixing ,testing commisioning heavy duty Wall mounted air circulating turbo force fan of size 450 mm sweep,230 volts 50Hz,0.9 power factor ,1440 RPM motor speed , single phase,revesable rotation including suiatble mounting bracket for fan complete all as specified and directed by Engr-in-charge. Make- Havells/Usha/Crompton Greaves.Note -1.Making hanging arrangemnt in wall of appropriate size to fix Bolts, giving suitable shape and making good the disturbed surface with cement mortor plastering and matching with existing surface including in item rates.
Material and labour for Point wiring using approved colour coding as per IS ( Red, black and green for single phase circuit ), with 1.5 Sq mm cross sectional area,single core, multi stranded copper conductor (FRLS) PVC insulated and unsheathed electrical cable ISI Marked and including stove enamelled steel conduit not less than 20 mm and conduit accessories fixed in wall/roof/floor and making good the disturbed surface with cement mortor plastering and matching with existing surface including PVC insulated multi-stranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly for One light / fan point controlled by one way one flame proof LM6 controller complete all as specified. Note - 1.Flame proof switch and socket to be measured and paid separately in respective items.
Supply and fixing flame proof rotary type with terminal box in LM6, 16A single pole 250 V grade ISI marked complete all as specified
Material and labour for SMC box inner dimension of 450x450x200 mm with hinged door including 8 mm thick bakelite sheet for fixing MCB DB SPN 4 way ,two flame switch mounted on the fabricated MS angle frame of size 25x25x3 mm with two coat of synthetic paint over a coat of redoxide primer and fixing the angle after grouting in the wall all as specified and directed. Make -Syntex or equivalent
Supply and fixing flame proof LED 2x10 watt tube light fitting including intergal reflector made of alluminium alloy LM6 with holder connector block etc prewired and including connecting up with twin core twisted flexible copper conductir with suitable size complete all as specified and directed.
Supply and fixing ,testing commisioning wind driven turbo ventilator of size 350 mm ,sweep suiatble for fixing on roof sheets complete and Wind operated turbo vantilator shall be made of high grade industrial aluminium of thickness not less than 0.50 mm and material of construction for hardware as stainless steel -304. the bearing shall be steel in completely enclosed and dust proof intergrated housing and aligned with each other. It shall have capability to rotate at nearly zero wind speed .turbo ventilotor shall have high exhaust capacity and these shall not be any exhaust problem due to air back draft. fixing arrangement shall have high quality rubberized hardware to prevent rain ingress and ventilator to be installed by manufacturer sattf only.Contrcator shall give no leackage guaranty for period for thee year from date of installation of turbo ventilators with all as specified.Make- MS turbo vantilator/airier Vents/MS Aren turbo ventilators.
M& L for Gong bell 240 volts complete
Supply and fixing sheet metal enclosure for DB double door, IP-42 when MCBs to be used SPN, 2 way, 240 V with 200 Amps rated bus bar size,
Material and labour for sheet metal enclosure MCB DB, SPN, 240 volts, 4 way, double door type grouting in wall in CM, making good of disturbed surfaces and matching with existing and electrical connections complete.Make :Legrand/ Schneider/Indo Asian (optipro)
Supply and fixing MCB SPN, 240 volts AC 50 Hz, 20 Amps all as directed. Make : Legrand/ Schneider/ Indo Asian (optipro)
Supply and fixing MCB SPN, 240 volts AC 50 Hz, 10 Amps all as directed. Make : Legrand/ Schneider/ Indo Asian (optipro)
Supply and fixing MCB SP 240 volts, 10 KA, C-Series 6 to 32 Amps complete all as specified Make : Legrand/ Schneider/ Indo Asian (optipro)
Material and labour for concealed sub main wiring with 2 single core PVC insulated, unsheathed copper conductor stranded 1100 volt grade cable of size 4 sqmm (FRLS) drawn in and incl stove enamelled steel conduitof size not less than 20 mm dia ISI marked with all accessories such as tee, bend, joint cover etc PVC insulated,one run of unsheathed copper conductor stranded 1100 volt grade cable of size 4 sqmm (FRLS) cable as continuous earth lead complete all as specified and colour coding of cables such as Phase-Red, Neutral-Black and Earth-Green
Material and labour for earthing complete with GI earth plate electrode of size 60 cm X 60 cm X 6mm thick burried directly in ground, earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth wire of size 4 mm dia as earth lead by means of bolts, nuts check nuts and washer of GI or steel all as shown in electrical plate No.3 of SSR Pt-I, connected to earthing lead upto main switch board/main board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit pre-cast RCC cover, charcoal/salt, funnel with wire mesh etc complete all as specified and directed Note :- (i) The rate quoted shall also deemed to include the cost of GI earth strip and protection pipe upto 7.5 Mtr beyond the earth plates electrode and also the cost of the Test point. (ii) Joining of GI earth wire with pipe of the test point shall be done by using suitable cable lugs.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth for laying of cables up to proper level complete.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm thick soil complete all as specified and directed at site by
Removing surplus exacavated material from excavation not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point complete all as specified and directed by Engr-in-charge.
Material and labour for cutting of bituminous road/ hard standing/hard rock/wall up to a size not exceeding 20 cm width and not exceeding 60cm in depth for laying of protection pipe for cable including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1, 40 mm grade crushed stone aggregate and block top with black bituminous upto existing surface level or removing the inter locking tiles carefully and refixing properly as per existing surface including suitable size of GI pipe(if necessary) complete all as specified and as directed by Engineer-in-charge. 4. GI Pipe shall measured and paid separately under relevant item.
Supply and filling dry river sand in trenches including spreading for cushioning of LT UG cablec and punning down complete all as speified and directed by Engr-in-charge.Note : Punned down thickness shall be measured and paid
Material and labour for well burnt as class ‘B’ bricks as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench complete.
Material and labour for XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 6 Sq mm 02 Core laying in trenches/cable ducts, fixed to wall/pole complete all as specified and directed of following sizes
Material and labour for XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 4 Sq mm 4 Core laying in trenches/cable ducts, fixed to wall/pole complete all as specified and directed of following sizes
Supply & fix GI tubing light grade of size 40 mm dia fixed on pole / laid in trenches / laid in road croosing as protection pipe for under ground cable including provisioning of nuts, bolts, washers, specials and clamps etc. complete all as speified and directed for following sizes :
Supply and fix in repairs LED street light fittings 45 watts (IP66) with LM6 pressure die cast aluminium housing and has lenses specially designed for street light fitting with polycarbonate cover including manufacturers logo embossed on the housing for traceability (stickering/ printing not acceptable), system level efficacy of the luminarie is 100lm/W at L70. The color temparature is arround 6500K with a color rendering index of 70. The luminaire if IP:66 protected with IK05 impact resistance, electronic driver complaint to IEC safety standards with power factor is greater than 0.9, voltage variation range 120-270V, THD less than 20%, high and low protection along with a surge protection of 5 KV, LED with individual peanut lens and lena plate for better optics. The product should be tested for IEC60598 safety standards, LM80 report for LED, entire product incl 3x1.5sqmm PVC insulated connection cable from fitting to OH line/ junction box in heavy duty PVC conduit including taking down the old u/s one complete all as specified and directed. Make : CG/Wipro/Havells
Supply and fix street light terminal boxes factory made, made out of 2.0 mm thick PVC sheet, powder coated with hinges and door with locking arrangements of size 300 x 250 x 150 mm housing in and including three phase cable connector of suitable size and one No of MCB SP 6 Amps, 240 Volts, in/out cable gland of suitable size of cables complete fixed on street light pole with clamp/bracket, nuts, bolts and washers etc complete all as specifed and directed by Engr-in-charge.
Supply and fix of non metallic rigid PVC conduit medium grade 20 mm dia ISI marked with fitting , fixed on pole with sheet clamp including mouth pieces and provide three core copper cable of size 2.5 sqmm and connection to street Light with control box complete all as directed.
Supply & Erecting Mild steel tubular swaged pole 9.0 meter long 410, SP-31 complete with cast iron base plate, bracket, final taper plug, bolt, nuts & screws and painted on both side (internally & externally), external surface painted with two coat of aluminum paint over coat of primer and painting with black upto 1.5 meter from top of PCC coping white colour paint as in strips of equal width with marking pole numbers by using one coat of synthetic enamel paint and provide necessary PCC/ foundation below GL as shoun in TD drawing in cluding coping plastering and coping complete all as specified and as directed.
RAMESH BABU CO
Shanthi Construction
Aditya Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .