Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 CrAccepted-AOC H NO 2715 SECTOR 9 11 HISAR 125001 HARYANA | HISAR | HARYANA | 125001 | ₹9.4 Cr | L1 | Accepted-AOC BEING LOWEST BIDDER |
| 2 | L2₹9.5 Cr+₹13.4 L (1.43%)Rejected-Finance 05 INFRONT OF AMIT HOTAL AURANGABAD AURANGABAD BIHAR 824101 UDYAM BR 03 0011066 | AURANGABAD | BIHAR | 824101 | ₹9.5 Cr+₹13.4 L (1.43%) | L2 | Rejected-Finance BEING OTHER THAN LOWEST BIDDER |
| 3 | L3₹10.7 Cr+₹1.4 Cr (14.8%)Rejected-Finance | ₹10.7 Cr+₹1.4 Cr (14.8%) | L3 | Rejected-Finance BEING OTHER THAN LOWEST BIDDER |
| 4 | L4₹11.4 Cr+₹2.1 Cr (22.3%)Rejected-Finance EAST LANE GALI NO 01 ABROL NAGAR PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | ₹11.4 Cr+₹2.1 Cr (22.3%) | L4 | Rejected-Finance BEING OTHER THAN LOWEST BIDDER |
| 5 | L5₹12.4 Cr+₹3.0 Cr (32.3%)Rejected-Finance CONGRESS BAZAR PATHANKOT 145 001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹12.4 Cr+₹3.0 Cr (32.3%) | L5 | Rejected-Finance BEING OTHER THAN LOWEST BIDDER |
Tender Value
₹10.9 Cr
EMD Value
₹8.7 L
Closing Date
19 Jan 2024, 6:00 pmClosed
CE AF Udhampur Zone
HQ CE AF Udhampur Zone Udhamapur J and K
CA NO CEAFU-15-2023-24 PROVISION OF CERTAIN WORK SERVICES FOR INDUCTION OF MRSAM AT AF STN PATHANKOT
2023_MES_621635_1
CEAFU-15-2023-24
Open Tender
Civil Works
Lump-sum
608 days
Pathankot
As per tender documents and as per policy in vogue
8 documents required · 8 mandatory
₹3,000
GE AF Pathankot
₹8.7 L
Yes
HQ CE AF Udhampur Zone
6 Mar 2024
4 Oct 2023
27 Jan 2024
6 Nov 2023
19 Jan 2024
2 Jan 2024
4 Oct 2023 - 18 Oct 2023
19 Oct 2023
Amount
SCHEDULE `A' PART-I (BUILDING WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Construction of Parking Shed of size 37190mm x 13600mm and 1500mm wide ramp with 1000mm wide platform on both side, for 16 four wheeler and 30 two wheeler, RCC framed construction, RCC roof, with front and back side ramp and platform complete all as shown on drawings and as specified.
Construction of Parking Shed of size 30190mm x 7030mm and 1500mm wide ramp with 1000mm wide platform on front side, for 05 four wheeler and 30 two wheeler, RCC framed construction, RCC roof, with front side ramp and platform complete all as shown on drawings and as specified.
Construction of Sub station building of size 5000mm x 4000mm, RCC framed construction, RCC roof with front side ramp complete all as shown on drawings and as specified.
Total amount of Schedule 'A' PART-I (BUILDING WORK)
Total amount of Sch 'A' PART-II (Sec-I) (INTERNAL ELECTRIC SUPPLY WORKS)
SCHEDULE `A' PART-II (SEC-II) (INTERNAL ELECTRIC SUPPLY WORKS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply and fixing 8 module modular metal Flush box as per site requirement complete all as specified and directed by Engineer-in-Charge.
S & F LED batten surface / wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption <20W, luminaire lumen >2000 lm, system efficiency of > 120 lumens/W, LED Make: Nichia/ Cree/ Everlite / Eclison/ Osram/ Lumiled, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class 1, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficiency>85%, power factor > 0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50,000 burning hrs (min) as per L7O criteria, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level < 60 V DC as per IEC standard with LM70 & LM 80 certification all as specified and directed.
Supply & fixing Bracket made out of GI light grade pipe of size 40 mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos MS clamp 50mm x 5mm and 04 sets of nuts,bolts and washers painting with two coats of synthetic enamel paint over a red oxide primer complete all as specified and as directed by Engr-in-charge.
Supply and fixing MCB Single Pole 2 Amps rating 240 Volts, 10KA 'C' curve miniature circuit breaker complete with connection testing and commissioning complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing MCB Single Pole 6 Amps rating 240 Volts, 10KA 'C' curve miniature circuit breaker complete with connection testing and commissioning complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and neutral and current carrying capacity 10 AMP, in the MCB DB Complete with connection testing and commissionincomplete all as specified and directed by Engr-in-charge.
Supply and fixing 2ft x 2ft recess mounted full panel LED luminaire with white powder coated housing acting as heat sink and frame in CRCA sheet, high efficiency LED grade diffuser , in built electronic driver duly wired up to terminal block, power consumption< 36W, luminaire lumen > 3500lm and system efficiency >120lm/W, CRI>80, LED Make:- Nichia/ Cree/ Everlite / Eclison/ Osram/ Lumiled with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class 1, colour temp -5700K, Ingress protection IP 20, , driver efficiency >85%, 50,000 burning hours (min) as per L70 criteria, ambient temp 0 to 500C, power factor >0.95, THD < 10% , surge protection in CM -3 KV, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level <60V DC as per IEC standard, with LM79 & LM80 certification all as specified and directed.
Supply and fixing Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 6 way with IP-54 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases cutting in wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. Note - MCBs will be measured separately.
Sub Total amount of Sch 'A' PART-II (SEC-II) (INTERNAL ELECTRIC SUPPLY WORK)
Total amount of Sch 'A' PART-III (Section-I) (ROAD/PATH/CULVERTROAD FURNITURE WORK)
Sch 'A' PART-III (Section-II) (ROAD/PATH/CULVERT/ROAD FURNITURE WORK) Note: This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply and fixing speed breaker made out of ABS engineering plastic, dynamically designed of size 250mm x 350mm x 50mm high, fitted with 4 Nos higly reflective reflectors, 02 Nos on each side including 04 Nos of fixing nails along with cement mortar bedding complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing high density grade reflectors/delineators of 75 mm O/D heavy duty steel pipe 1.20 mtr high with head cap hydraulic machine pressed and hold fast, weld mesh to be fixed in PCC (1:2:4) of block size 150x150x150mm including necessary excavation with two coats of black paint by hot processing over a coat of red oxide and refective strips 03 Nos around the pipe in full perimeter all as per MOST and IRC specification complete in all respect and complete all as specified.
Supply and fixing 3 M USA Brand Markers Series 290 (Cat Eyes) Body made of poly carbonate with electronically welded prismatic retro-reflective lens on both side for maximum Retro Reflection in wet and dry conditions. The material should be non breakable, dustproof and fixing with bitumen adhesive BT-69 complete all as directed.
Taking down old Cat eye of any description and size complete as specified
Taking down old delineator of any description and size complete as specified
Material and labour for applying 2mm thick retroreflective thermoplastic road marking paint white or yellow with reflective sign glass beads @ 250 gms per Sqm area confirming to BIS specifications for lines, dashes or arrows letters etc over bituminous surfaces/ pavments exceeding 10 cm width applied by machine as per manufacturers instructions complete all as specified and as directed by Engineer-in-Charge.
Sub Total amount of Sch 'A' PART-III (Section-II) (ROAD/PATH/CULVERT/ROAD FURNITURE WORK)
Total amount of Sch 'A' PART-IV (Section-I) (FENCING AND GATE WORK)
Sch 'A' Part-IV (Section-II) (FENCING AND GATE WORK) Note: This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
M&L for applying two coats of Acrylic exterior emulsion paint with camouflage pattern (four) or more shades over a coat of primer of olive green colour as directed by Engineer-in-Charge and as required at site including necessary scaffolding and other safety arrangement to work up to a height of 8 metre metrescomplete all as specified and directed by Engineer-in-Charge.
Sub Total amount of Sch 'A' PART-IV (Section-II) (FENCING AND GATE WORK)
Total amount of Sch 'A' PART-V (EXTERNAL WATER SUPPLY WORK)
Sch 'A' Part-V (Section-II) (EXTERNAL WATER SUPPLY WORK) Note: This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Cutting existing steel tubing for alterations or additions, Screwing existing steel tubing for alterations or additions screw on pipe to form connector done in position without taking down existing for upto 100 mm bore GI Pipe complete all as specified and directed
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including supply and providing HDPE pipe of 150 mm dia suitable for 0.40 mpa working pressure complete all as specified and as directed. (Qty = 24.00 RM for External water Supply and 36.00 RM for External Electric Supply)
Supply and laying in trenches ductile iron pipes, socket and Spigot ends, of size DN100 mm dia bore, ISI marked Centrifugally Cast (Spun) Ductile Iron Pressure pipes conforming to IS:8329/2000 classification K-7 rating, suitable for push-on-joint (Rubber gasket-D jointing) with cement mortor lining inside the pipes and outside zinc coating with Bituminous finish coat as per IS:8329/2000 including EPDM rubber joints conforming IS: 5382 of 1985 all as specified and as directed by Engineer-in-Charge. NOTE: Excavation and earth work shall be measured and paid separately under relevant item/part of Schedule 'A'/this BOQ.
Material and labour for construction of valve chamber of size 900 x 900mm and 900 mm deep dimensions (Over all internal dimension) with PCC foundation, brick masonry walls, Plastering, PCC Coping, white washing, mild steel chamber cover, painting to chamber cover including Excavation and earth work in any type of soil complete all as specified below:-Valve chamber shall be provided with the following specifications:- (i) Cement concrete for foundation (1:4:8) type D2 using 40mm graded stone aggregate 150 mm thick extended up to 150 mm beyond the outer face of brick masonry. (ii) Walls of valve chamber 230 mm thick using brick masonary setting in CM 1:6 complete. (iii) Internal and exposed surfaces of valve chamber brick masonry surface shall be plastered with CM (1:4), 15 mm thick finished even and smooth.(iv) 50 mm thick coping in PCC 1:3:6 type C1 over brick masonry wall. (v) Entire plastered surfaces shall be treated with 3 coat of white wash. (vi) Chamber cover shall be of 6 mm thick MS sheet with 30 x 30 x 5 mm size angle iron frame with hold fast and locking arrangement. Steel surface shall be painted with two coats of synthetic paint of first quality over one coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge.
Sub Total amount of Sch 'A' PART-V (Section-II) (EXTERNAL WATER SUPPLY WORK)
Total amount of Sch 'A' -VI (Section-I) (EXTERNAL ELECTRIFICATION WORK)
Sch 'A' Part-VI (Section-II) (EXTERNAL ELECTRIFICATION WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply, installation , testing & commissioning of HT 11 KV, 630A, VCB panel for outgoing feeder compatible with existing VCB HT Panel comprising of 01 Incoming and 04 Outgoing indoor type totally enclosed, rupturing capacity 350 MVA,free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontal isolation, horizontal draw out type VCBs with copper bus bars, Self supported Insulated Bus bar with full voltage rated should be used.Back entry type complete VCB panel conforming to IEC 62271-200 standards and IP 4X class of protection comprising necessary bus-bars extension and connections and following protective and control devices as specified below. The switchgear and control gear panels shall be of the fully arc proof LSC 2B PM ( loss of service continuity metal parts) IAC AFLR( Internal Arc classification) for 26.3 kA for 3 Sec complete all as specified and as directed. The VCB and VCB Panel should be similar make only.The proposed HT Panel to be aligned with already existing VCB panels.
(d) Resin cast current transformers with ratio 200-100/1A with characteristics : Core 1- 2.5 VA, Class 0.5, Core 2.5 VA, class 5P10, burden depending upon knee voltage as per IS 2705- Part-IV.-Set of three -01 Job (e) SCADA Compatible Feeder Protection Relay 50/51(3-phase over current), 50/51N (Earth over current), 67P (3-phase directional over current), 67N (Earth Fault Directional over current), 51V (Voltage controlled over current), 37 (3-phase uner current), 46 (Negative phase sequence over current), 59N (Residual over voltage), 32 (directional power protection (under active / over active / reactive power), 81 U/O (under / over frequency), 49 (Thermal overload), 79 (Auto Reclose), 50 BF (Circuit Breaker Failure Detection), cold pickup, inrush blocking relay will be on Modbus protocol -01 No. (f) Trip circuit supervision relay. (g) Master trip relay.
(h) 63 x Trafo fault Relay CV2D2J - 3 Nos. (j) Internal bus earthing (k) Manual trip switch. (l) Space heater with thermostat - 1 No. (m) Inside moving spot LED light fitting and switch (11W) - 1 No (n) Plug point with switch (5A, 230V) - 1 No. (o) Insulated Alumium bus bar (p) Manual charging/ operating arrangement. (q) Fuses for metering and protection system. (r) Push buttons for accepting faults and reset. (s) Rear bottom entry of HT cables. (t) LED indicating lamps (u) Auto trip (v) Spring charge motor (w) Trip circuit healthy (x) Trip circuit unhealthy (y) Breaker ON (z) Breaker OFF (aa) Complete control panel wiring with FRLS PVC insulated copper cable of size not less than 1.5 sqmm (ab) Civil works required for foundation as per manual of manufacturer (ac) Terminal block and breaker locking facility with key - 01 No
Note : (i) The proposed VCB will be used for outgoing purpose and has to be compatible with the existing ICOG VCB panels of 630 amp rating with horizontal isolation type with CT ratio 600-300/1A for Main Incoming and 200-100/1A outgoing . The Size of existing HT incoming panel is 4100 MM x 610MM x 6900MM and of make ABB and necessary extension of copper busbar is deemed to be included in the quoted rate. (ii) After taking shutdown contractor shall complete the commisioning of the Job within 24 hrs. (iii) Testing, calibration of relays/primary/secondary injection, testing the relays/submission of test report and control wiring/power wiring complete is included in the above scope of work. (iv) Drawing for panels shall be produced to the Engineer-in-charge and got approved from GE before placement of order by the contractor. (v) Pre-commissioning test of panels shall be carried by SEI /EI deputed by the deptt. (vi) Representative of Accepting officer will carry out factory inspection of HT VCB before dispatch. (vii) No channel partner manufacturer is permissible.All components of VCB panel shall be from OEM only.
Supply, installation, testing & commissioning of HT 11 KV, 630A, VCB panel ICOG comprises of 2 nos of VCB (01 No for I/C and 1 No for O/G) indoor type totally enclosed, rupturing capacity 350 MVA,free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontal isolation, horizontal draw out type VCBs with copper bus bars, Self supported Insulated Bus bar with full voltage rated should be used.back entry type complete VCB panel conforming to IEC 62271-200 standards and IP 4 x class of protection comprising necessary bus-bars extension and connections and following protective and control devices as specified below. The switchgear and control gear panels shall be of the fully arc proof LSC 2B, PM, IAC AFLR for 26.3 kA for 3Sec complete all as specified and as directed. The VCB and VCB Panel should be similar make only. (A) Incomer Vacuum circuit breaker 630A, HT, 11KV three phase, AC supply, breaking capacity 26.3KA/3 Sec at 11000V, short circuit ratings 3 seconds. Vacuum interrupters of the circuit breakers shall not be openly exposed design and shall be completely encapsulated in epoxy housing.VI Pressure 10-9 Bar. The Circuit Breaker shall be suitable for E2, M2 & C2 (Single capacitor Bank) class duty. The offered circuit breaker should have valid type tests to support the afore-mentioned duty class. Tripping and/or release coils shall have series / shunt trip. Integral spring charging handle to be provided in the VCB. -01 No
(d) Resin cast current transformers with ratio 100-50/1-1 with characteristics : Core 1- 2.5 VA, Class 0.5, Core 2.5 VA, class 5P10, burden depending upon knee voltage as per IS 2705- Part-IV.-Set of three -01 Job (e) Resin cast potential transformers with ratio 11 KV / 1.732,110 V/1.732,suitable VA burden class 0.5 with HT fuses,PT fuse should be gun type mounted on with drawable rack -01 No (f) SCADA Compatible Feeder Protection Relay 50/51(3-phase over current), 50/51N (Earth over current), 67P (3-phase directional over current), 67N (Earth Fault Directional over current), 51V (Voltage controlled over current), 37 (3-phase uner current), 46 (Negative phase sequence over current), 59N (Residual over voltage), 32 (directional power protection (under active / over active / reactive power), 81 U/O (under / over frequency), 49 (Thermal overload), 79 (Auto Reclose), 50 BF (Circuit Breaker Failure Detection), cold pickup, inrush blocking relay will be on Modbus protocol -01 No. (g) Trip circuit supervision relay. (h) Master trip relay.
(j) 63X Trafo fault Relay CV2D2J - 3 Nos. (kl) Internal bus earthing (l) Manual trip switch. (m) Space heater with thermostat - 1 No. (n) Inside moving spot LED light fitting and switch (11W) - 1 No (o) Plug point with switch (5A, 230V) - 1 No. (6) Insulated Alumium bus bar (r) Manual charging/ operating arrangement. (s) Fuses for metering and protection system. (t) Push buttons for accepting faults and reset. (u) Rear bottom entry of HT cables. (v) LED indicating lamps (i) Auto trip (ii)Spring charge motor (iii)Trip circuit healthy (iv) Trip circuit unhealthy (v)Breaker ON (vi) Breaker OFF (w) Complete control panel wiring with FRLS PVC insulated copper cable of size not less than 1.5 sqmm (x) Civil works required for foundation as per manual of manufacturer. (y) Terminal block and breaker locking facility with key . - 01 No
Note : (a) The following works before Commissioning of New VCB deemed to be included in the quoted rates:- (i) Tools & plants,safety devices like helmet,belt, HT/LT insulation govles, earth road, Megger etc shall be provided by the contractor . (ii) After taking shutdown contractor shall complete the commisioning of the Job within 24 hrs. (iii) Testing, calibration of relays/primary/secondary injection, testing the relays/submission of test report and control wiring/power wiring complete. (iv) Drawing for panels shall be produced to the Engineer-in-charge and got approved from GE before placement of order by the contractor. (b) Pre-commissioning test of panels shall be carried by SEI /EI deputed by the deptt. (c) Representative of Accepting officer will carry out factory inspection of HT VCB before dispatch. (d) No channel partner manufacturer is permissible.All components of VCB panel shall be from OEM only.
Supply and fixing street light IP-66 LED light fitting of capacity 60 Watts, 240Volts single phase 50 Hz consisting of aluminium pressure die cast housing with high purity PC fresnel diffuser with glass silicon gaskets complete assembly with LED and accessories toughened prewired upto terminal block confirming to IS 10322 part 5/sec1: 1967 with inbuilt integrated electronic LED driver voltage surge protection not less than 3 KV, 2/3 stage isolated driver, the LED lumen output colour temperature consistency compliant to LM 6600K standard system lumens of LED luminaire high lumen output minimum 130 lm/Watts complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing sheet moulding compound (SMC) junction box for and including three phase and neutral bus bar and MCB SPN 06 Amps, 250 Volts 50 Hz, 15 KA for control of sreet lights mounted on ploe with the provisions of cable entry and exit Make Sintex/hensel cat part No KF8350/ Siemens/L&T product code NO GSJB-2817 of size 280mm x 170mm x 130mm complete all as specified and as directed.
Supply and fixing digital timer switches 250 V single phase of 20 Amps rating with conactor fitted inside steel enclosure complete all as specified and directed.
Taking out extisting underground cables of any type and size and laying only to the location as decided complete all as specified and directed.
Dismantling of existing feeder pillar box comprising of bus bar and with MCCB upto 250 Amps complete all as specified and directed
S & F cable route indicator at the distance of 50 mtrs each made out of 45 x 45 x 5 mm angle iron, 80 mm long embedded in PCC block of suitable size with moulded lettter HT CABLE or LT CABLE suitably inscribed on Cast iron circular plate 8 mm thick 100 dia including painting with two coats of synthetic enamelled paint over a coat of red oxide primer including neccessary PCC 1:3:6, type C-2 (using 40 mm graded aggrregate) block of suitable size and neccessary earth work and excavation all as specified and directed.
Supply, testing and commissioning of outdoor weather & dust vermin proof L.T. Panel board factory fabricated indoor cubicle type totally enclosed .The Panels must be design and verified as per the IS/IEC 61439-01 & 2 with complete type test certificates for conformance to IS / IEC 61439 -1 and 2, with 65 KA 1 sec along with MCCB mounted in switch boards with aluminium bus bars as mandatory as conformed to IEC 61641 with internal arc containment fault level of 65 KA/03 Sec and shall be suiatbale for Seismeic Zone III/IV Zone including the type test conducted at ERDA/CPRI for seismic test.All MCCB/ ACB panel should be single Tier for easy cable termination.Cable termination space should be adequate to safely gland and terminate al/cu cables for the given current ratings with Form B seperation for Incoming MCCB / ACB feeders and For Outgoing MCCB feeders. The Switch board cubicles shall have steel frame work enclosed on all sides and top by CRCA sheet steel of Minimum 3.15mm thickness.The panel shall have integral base frame of 100 MM ISMC base channel.removeable undrilled gland plates shall be fitted for bottom cable entry.
Fixing only old steel pole of any type dismantled from relevant item of Schedule 'A' Part/this BOQ by carring it to the new position and fixing nad erecting it to true vertical position complete all as specified and as directed. (Excavation, PCC etc shall be measured and paid separately)
Refixing of old structural steel dismantled from from relevant item of Schedule 'A' Part/this BOQ including suppling and fixing of nuts, bolts, washers, etc including applying one coat of synthetic enamel paint after preparation of old steel surfaces as required at site complete all as specified and as directed..
Total amount of Sch 'A' PART-VI (SEC-II) (EXTERNAL ELECTRICAL SUPPLY WORK)
Total amount of Sch 'A' PART-VII (Section-I) (DIFFIRENT TYPE OF EARTHING/CHEMICAL EARTHING WORKS)
Sch 'A' PART-VII (Section-II) (DIFFERENT TYPE OF EARTHING/CHEMICAL EARTHING WORKS) Note: This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4 mm dia galvanized earth lead wire by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour of the following: - (a) Excavation and earth work in any type of soil or drilling hole for electrode. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 15 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note: (1) The earth resistance shall be less than 5 ohms after completion of earthing. If the desired earth resistance is not obtained, the earthing shall be re-done by the Contractor by replacing the existing soil by good quality soil to achieve the desired result at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 25 x 4mm GI strip as earth lead burried into ground and connected by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour of the following: - (a) Excavation and earth work in any type of soil or drilling hole for electrode. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 40 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note: (1) The earth resistance shall be less than 5 ohms after completion of earthing. If the desired earth resistance is not obtained, the earthing shall be re-done by the Contractor by replacing the existing soil by good quality soil to achieve the desired result at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Sub Total amount of Sch 'A' PART-VII (Section-II) (CHEMICAL EARTHING WORKS)
Total amount of Sch 'A' PART-VIII (Section-I) (SITE CLEARANCE WORKS)
Sch 'A' PART-VIII (Section-II) (SITE CLEARANCE WORKS) Note: This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Cutting of bushes, shrubs of n. exc. 15 cm girth including taking out roots of shrubs/bushes from ground and density of bushes/shrubs can vary from 8 to 12 nos. per sqm area including making the ground levelled and removal of shrubs, bushes and grass outside from Technical area and deposited complete all as specified and directed by Engineer-in-Charge
M&L for bringing extra earth i.e granular material if required from outside ministry of defence (MOD) land at a distance exc 1.50 Km and not exc 6.00 Km for filling and raising (or lowering) earth, spreading in layer not exc 25 cm thick, watering, compacting and finishing to required gradient/ shape and deposited where complete all as specified and directed by Engineer-in-Charge
Sub Total amount of Sch 'A' PART-VIII (Section-II) (SITE CLEARANCE WORKS)
Total amount of Sch 'A' Part-IX (DEMOLITION WORK)
NOTE: Amount against schedule of credit for retrieved materials mentioned under relevant part of Sch of Credit of tender document in PDF form will be deducted offline/manually from overall amount quoted by the lowest bonafide bidder during award of contract.
Sandeep Kumar
RHG Constructions Private Limited
SRM BUILDERS AND ENGINERS PVT.LIMITTED
Shekhar Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .