Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.1 CrAdmitted-Finance AT BANTARA PO BHOTAKA PS KUAKHIA DISTT JAIPUR ODISHA PIN 755009 | BHOTAKA | JAIPUR | ODISHA | 755009 | -16.52% | ₹1.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.1 CrAdmitted-Finance AT SOLAPATA PO BADABIRUAN PS PANIKOILI DIST JAJPUR PIN 755015 | JAJPUR | JAJPUR | ODISHA | 755015 | -11.30% | ₹1.1 Cr | L2 | Admitted-Finance |
| 3 | L3₹1.3 CrAdmitted-Finance | -0.99% | ₹1.3 Cr | L3 | Admitted-Finance |
| 4 | L4₹1.3 CrAdmitted-Finance AT PO BAHARANA P S NIALI DISTRICT CUTTACK PIN 754004 | BAHARANA | CUTTACK | ODISHA | 754004 | +0.00% | ₹1.3 Cr | L4 | Admitted-Finance |
| 5 | L4₹1.3 CrAdmitted-Finance AT BHUBAN PO DHARMASALA DIST JAJPUR PIN 755008 | BHUBAN | JAJPUR | ODISHA | 755008 | +0.00% | ₹1.3 Cr | L4 | Admitted-Finance |
Tender Value
₹1.3 Cr
EMD Value
₹1.3 L
Closing Date
19 Feb 2026, 5:00 pmClosed
Chief Construction Engineer,R.W Circle KPD-JJP
O/o CCE,R.W Circle,Kendrapara-Jajpur
Construction of RW Sub-Division Office cum section office -I and Section office- II at Rasulpur_building
2026_CERWI_125582_1
Tender Online RCK-2/26
National Competitive Bid
Civil Works - Buildings
365 days
Jajpur
Please refer tender documents
2 documents required · 2 mandatory
₹10,000
₹1.3 L
Yes
20 Mar 2026
5 Feb 2026
20 Feb 2026
5 Feb 2026
19 Feb 2026
5 Feb 2026
5 Feb 2026 - 19 Feb 2026
Earth work in excavation in foundation in hard soil including hard moorum, stony earth mixed with boulders (except sheet rock & boulders requiring blasting) with all leads & lifts including dressing and leveling the bed and depositing the excavated earth at places away from work site with all leads & lifts including cost of all labour, cess & T&P and dewatering if required for the work etc. complete and as directed by the Engineer-in-charge.---a) Ground Floor
Providing & filling manualy with aproved quality of sand in layers not exceeding 150mm thick including watering ramming to proper density with cost,conveyance, royality, taxes of all materials and cost of all labour & T & P as required for the item of work including cess etc complete as per specification & direction of Engineer-in-charge.a) Ground Floor
Providing Cement Concrete (1:3:6) with 40mm size clean hand broken granite metal of approved quality from approved quarry including hoisting lowering & levelling in position to required level in each layer not exceeding 15cm thick in foundation including frame work where necessary ramming using vibrator to proper slope and levelling curing dewatering with cost conveyance taxes royality, labour of all materials and including hire & running charges of machineries T&P required for the work including supplying & working of pumps and cess as per the specifiction and direction of Engineer-in- charge.--a) Ground Floor
Fly Ash brick masonary in Cement Mortar (1:6) in Foundation / Superstructure using-Fly Ash.-brick of 25cm X 12cm X 8cm size having a crushing strength in between 75kg to 100 kg per Sq.cm with dimensional tolerance ± 8% including splays cutting circular moulding chamfering & corbelling watering and curring for 7days after immersing the bricks in water for six hours before use etc. complete including cost & conveyance of all materials & labour required for the work with all taxes & royalties with all T&P & cess etc, complete in all respect as per the direction of Engineer-in-charge. ---a) Ground Floor
Providing Reinforced cement concrete M20 Grade with 20mm & downgrade size clean crusher broken granite chips aggregate of approved quality from approved quarry including hoisting, lowering & levelling in position to required level in each layer not exceeding 15cm thick including frame work where necessary ramming using vibrator to proper slope and levelling curing dewatering if necessary with cost, conveyance taxes royalty labour of all materials and including hire and running charges of machinaries T&P required for the work including supplying and working of pumps and cess as per the specification and direction of Engineer-in-charge. -----a) Ground Floor----Column base
Gr-Beam
Lintel
Chajja
Wall beam /column
Shelve
Roof slab
Staircase
b) First Floor---Column
b) First Floor---Lintel
b) First Floor---Chajja
b) First Floor---Wall beam
b) First Floor---Shelve
b) First Floor---Roof slab
b) First Floor---Staircase
c) Second Floor---Column
c) Second Floor---Lintel
c) Second Floor---Chhaja
c) Second Floor---Wall beam
c) Second Floor---Roof slab
Supplying fitting and placing uncoated HYSD bar reinforcement complete as per drwing and technical specification ncluding cost conveyance, royalties and all taxes of all materials and cost of all labour with T&P required for the work etc.complete as directed by the Engineer-in-charge.---a) Ground Floor
Supplying fitting and placing uncoated HYSD bar reinforcement complete as per drwing and technical specification ncluding cost conveyance, royalties and all taxes of all materials and cost of all labour with T&P required for the work etc.complete as directed by the Engineer-in-charge.---b) First Floor
Supplying fitting and placing uncoated HYSD bar reinforcement complete as per drwing and technical specification ncluding cost conveyance, royalties and all taxes of all materials and cost of all labour with T&P required for the work etc.complete as directed by the Engineer-in-charge.---c) Second Floor
Fly Ash brick masonary in Cement Mortar (1:6) in Foundation / Superstructure using-Fly Ash.-brick of 25cm X 12cm X 8cm size having a crushing strength in between 75kg to 100 kg per Sq.cm with dimensional tolerance ± 8% including splays cutting circular moulding chamfering & corbelling watering and curring for 7days after immersing the bricks in water for six hours before use etc. complete including cost & conveyance of all materials & labour required for the work with all taxes & royalties with all T&P & cess etc, complete in all respect as per the direction of Engineer-in-charge. ---a) Ground Floor--Foundation
Fly Ash brick masonary in Cement Mortar (1:6) in Foundation / Superstructure using-Fly Ash.-brick of 25cm X 12cm X 8cm size having a crushing strength in between 75kg to 100 kg per Sq.cm with dimensional tolerance ± 8% including splays cutting circular moulding chamfering & corbelling watering and curring for 7days after immersing the bricks in water for six hours before use etc. complete including cost & conveyance of all materials & labour required for the work with all taxes & royalties with all T&P & cess etc, complete in all respect as per the direction of Engineer-in-charge. ---Super Structure
b) First Floor---Super Structure
c) Second Floor---Super Structure
12mm (1/2") thick cement plaster in C.M (1:6) finsihed smooth to out side brick walls after racking out the joints including watering & curing for seven days with cost and conveyance of all materials and laobur with T&P required for the work with all taxes, royalties & cess etc, complete in all floors as per direction of Engineer-in-charge. ---a) Ground Floor
12mm (1/2") thick cement plaster in C.M (1:6) finsihed smooth to out side brick walls after racking out the joints including watering & curing for seven days with cost and conveyance of all materials and laobur with T&P required for the work with all taxes, royalties & cess etc, complete in all floors as per direction of Engineer-in-charge. ---b) First Floor
12mm (1/2") thick cement plaster in C.M (1:6) finsihed smooth to out side brick walls after racking out the joints including watering & curing for seven days with cost and conveyance of all materials and laobur with T&P required for the work with all taxes, royalties & cess etc, complete in all floors as per direction of Engineer-in-charge. ---c) Second Floor
16mm (5/8") thick cement plaster in C.M. (1:6) finished smooth to inside surface of 9" thick brick wall after racking out the joints including watering & curing for seven days with cost and conveyance of all materials and labour with T&P required for the work with all taxes, royalties & cess etc, complete in all floor as per direction of Engineer-in-charge. ---a) Ground Floor
16mm (5/8") thick cement plaster in C.M. (1:6) finished smooth to inside surface of 9" thick brick wall after racking out the joints including watering & curing for seven days with cost and conveyance of all materials and labour with T&P required for the work with all taxes, royalties & cess etc, complete in all floor as per direction of Engineer-in-charge. ---b) First Floor
16mm (5/8") thick cement plaster in C.M. (1:6) finished smooth to inside surface of 9" thick brick wall after racking out the joints including watering & curing for seven days with cost and conveyance of all materials and labour with T&P required for the work with all taxes, royalties & cess etc, complete in all floor as per direction of Engineer-in-charge. ---c) Second Floor
6 mm thick cement plaster (1 : 4) finished smooth per 1 Sqm. Sand ( Screened & Washed). with all taxes royalties & cess etc, complete as per direction of Engineer-in-charge. ---a) Ground Floor
6 mm thick cement plaster (1 : 4) finished smooth per 1 Sqm. Sand ( Screened & Washed). with all taxes royalties & cess etc, complete as per direction of Engineer-in-charge. ---b) First Floor
6 mm thick cement plaster (1 : 4) finished smooth per 1 Sqm. Sand ( Screened & Washed). with all taxes royalties & cess etc, complete as per direction of Engineer-in-charge. ---c) Second Floor
Fixing vitrified tiles in floors treads or steps and landing on 20mm thick bed of cement mortar 1:4 (1Cement : 4 Sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of precast tiles complete in all respect as per the direction of Engineer in Charge.---a) Ground Floor
Fixing vitrified tiles in floors treads or steps and landing on 20mm thick bed of cement mortar 1:4 (1Cement : 4 Sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of precast tiles complete in all respect as per the direction of Engineer in Charge.---b) First Floor
Fixing Ceramic tiles in dados,skirting and in rises of steps on 12mm thick bed of cement plaster (1:3) joined with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing including cost of tile. complete in all respect as per the direction of Engineer in Charge.---a) Ground Floor
Fixing Ceramic tiles in dados,skirting and in rises of steps on 12mm thick bed of cement plaster (1:3) joined with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing including cost of tile. complete in all respect as per the direction of Engineer in Charge.---b) First Floor
Fixing chequred tiles in floors,treads and landings on 25mm thick bed of cement mortar (1:1) joined with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing including cost of tile.---a) Ground Floor
Fixing Ceramic tiles in dados,skirting and in rises of steps on 12mm thick bed of cement plaster (1:3) joined with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing including cost of tile. complete in all respect as per the direction of Engineer in Charge.-----a) Ground Floor
Fixing Ceramic tiles in dados,skirting and in rises of steps on 12mm thick bed of cement plaster (1:3) joined with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing including cost of tile. complete in all respect as per the direction of Engineer in Charge.-----b) First Floor
Providing fitting, fixing of Al. Door with OEL anodized Al. door section 9202 as vertical member, 9201 as top member and 12mm thick pre-laminated board fixed on door frame by means of tapered clip No. 4660 and the frame to be completed by means of jointing angle No. 1885 including all cost of labour, T&P hire charges of drilling machine etc.complete with all taxes royalties & cess etc, complete in all floors as per direction of Engineer-in-charge. ---a) Ground Floor
Providing fitting, fixing of Al. Door with OEL anodized Al. door section 9202 as vertical member, 9201 as top member and 12mm thick pre-laminated board fixed on door frame by means of tapered clip No. 4660 and the frame to be completed by means of jointing angle No. 1885 including all cost of labour, T&P hire charges of drilling machine etc.complete with all taxes royalties & cess etc, complete in all floors as per direction of Engineer-in-charge. ---b) First Floor
Supplying fitting fixing up window Sliding type madeup alumnum section No.9778 as window frame section No.409 4096 and 9777 3994 as shutter frame with 5mm thick black glass as panel fitted with rubber beading including locking arrangement including all fitting including cost of materials all taxes labour TP etc. complete as per direction of EIC--a) Ground Floor
Supplying fitting fixing up window Sliding type madeup alumnum section No.9778 as window frame section No.4095, 4096 and 9777 3994 as shutter frame with 5mm thick black glass as panel fitted with rubber beading including locking arrangement including all fitting including cost of materials all taxes labour TP etc. complete as per direction of eic-b) First Floor
Iron work wrought and put up in window grating including drilling holes in choukathas , including cost conveyance royalties and all taxes of all materials alongwith T&P required for the work in all respect as per the direction of Engineer in Charge.---a) Ground Floor
Iron work wrought and put up in window grating including drilling holes in choukathas , including cost conveyance royalties and all taxes of all materials alongwith T&P required for the work in all respect as per the direction of Engineer in Charge.---b) First Floor
Iron work wrought and put up in window grating including drilling holes in choukathas , including cost conveyance royalties and all taxes of all materials alongwith T&P required for the work in all respect as per the direction of Engineer in Charge.---c) Second Floor
Supplying, fitting and fixing G.S. Door & window G.S. grills as per the approved design and drawing with all cost,conveyance,taxes, cess with all labour and T&P etc.complete in all respect as per direction of the Engineer-in-charge. ( Weight to be measued before fitting and fixing and which shall be paid only after fixing )---Compound Wall
Supplying, fitting afixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc. with cost conveyance, taxes of all materials labour, T&P etc. required for the complete in all respect. ---a) Ground Floor
Supplying, fitting afixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc. with cost conveyance, taxes of all materials labour, T&P etc. required for the complete in all respect. ---b) First Floor
Finishing surface of wall with cement based wall putty ( water Based ) of approved make and finished smooth and even surface to receive painting including cost of scaffolding, staging including cost of all materials, labour etc.complete as per direction of Engineer-in-Charge.---a) Ground Floor
Finishing surface of wall with cement based wall putty ( water Based ) of approved make and finished smooth and even surface to receive painting including cost of scaffolding, staging including cost of all materials, labour etc.complete as per direction of Engineer-in-Charge.---b) First Floor
Finishing surface of wall with cement based wall putty ( water Based ) of approved make and finished smooth and even surface to receive painting including cost of scaffolding, staging including cost of all materials, labour etc.complete as per direction of Engineer-in-Charge.---c) Second Floor
Wall Priming one coat with any approved shade of primer ( WBD ) on New Plastered surface of with any approved primer including cost of primer ( water Based ) of approved make and finished smooth and even surface to receive painting including cost of scaffolding ,staging including cost of all materials , labour etc.complete.---a) Ground Floor
Wall Priming one coat with any approved shade of primer ( WBD ) on New Plastered surface of with any approved primer including cost of primer ( water Based ) of approved make and finished smooth and even surface to receive painting including cost of scaffolding ,staging including cost of all materials , labour etc.complete.---b) First Floor
Wall Priming one coat with any approved shade of primer ( WBD ) on New Plastered surface of with any approved primer including cost of primer ( water Based ) of approved make and finished smooth and even surface to receive painting including cost of scaffolding ,staging including cost of all materials , labour etc.complete.---c) Second Floor
Wall painting two coats to walls with plastic emulsion paint of approved shade on New work one coat to give an even shade including cost of paint per 1 sqm. etc. complete as per direction EIC. (Ref. P-99, item-20 of A/R- 06). Data 10 sqm---a) Ground Floor
Wall painting two coats to walls with plastic emulsion paint of approved shade on New work one coat to give an even shade including cost of paint per 1 sqm. etc. complete as per direction EIC. (Ref. P-99, item-20 of A/R- 06). Data 10 sqm---b) First Floor
Wall painting two coats to walls with plastic emulsion paint of approved shade on New work one coat to give an even shade including cost of paint per 1 sqm. etc. complete as per direction EIC. (Ref. P-99, item-20 of A/R- 06). Data 10 sqm---c) Second Floor
Painting two coats with Weather coats with one coat of primer of approved shade by means of brush to outside surface of wall after cleaning the surface including cost of weather coats with all taxes and cost of all materials and cost of all labour with T&P required for the work complete. ---a) Ground Floor
Painting two coats with Weather coats with one coat of primer of approved shade by means of brush to outside surface of wall after cleaning the surface including cost of weather coats with all taxes and cost of all materials and cost of all labour with T&P required for the work complete. ---b) First Floor
Painting two coats with Weather coats with one coat of primer of approved shade by means of brush to outside surface of wall after cleaning the surface including cost of weather coats with all taxes and cost of all materials and cost of all labour with T&P required for the work complete. ---c) Second Floor
Painting two coats of enamel paint over a coat of primer to wood/iron work of any approved shade incluiding all taxes and cost of all materials and cost of all labour with T&P required for the work complete. ----a) Ground Floor
Painting two coats of enamel paint over a coat of primer to wood/iron work of any approved shade incluiding all taxes and cost of all materials and cost of all labour with T&P required for the work complete. ----b) First Floor
Painting two coats of enamel paint over a coat of primer to wood/iron work of any approved shade incluiding all taxes and cost of all materials and cost of all labour with T&P required for the work complete. ----c) Second Floor
Providing and Fixing of Paving Block etc complete.a) Ground Floor
Providing Cement Concrete (1:2:4) with 12mm size clean crusher broken granite chips aggregate of approved quality from approved quarry including hoisting, lowering & levelling in position to required level in each layer not exceeding 15cm thick including frame work where necessary ramming using vibrator to proper slope and levelling curing dewatering if necessary with cost, conveyance taxes royalty labour of all materials and including hire and running charges of machinaries T&P required for the work including supplying and working of pumps and cess as per the specification and direction of Engineer-in-charge.---a) Ground Floor
2.5 cm thick grading concrete (1:2:2) on roof slab with 6mm size hard granite chips on new work with all taxes royalties & cess etc., complete as per direction of Engineer-in-charge. ---a) First Floor
Earth work in all kinds of soil in excavation of foundation trenches within 50 m initial lead including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30 in depth and as per direction of E.I.C.a) Initial lift up to 1.50m
b) From 1.50m to 3.0mtr depth
Supplying all materials, labour T&P and filling in F&P with river sand well watered and rammed including conveyance of all materials to worksite payment of royalty, taxes etc. all complete as per direction of E.I.C.
Supplying all materials, labour T&P and providing c.c (1:3:6) using 4cm h.g. metal including watering, curing, coveyance of all materials to worksite payment of royalty, taxes etc. all complete as per specification and direction of E.I.C.
Supplying all materials, labour T&P and providing c.c (1:1.5:3) using 12 mm h.g. chips including watering,curing, coveyance of all materials to worksite payment of royalty, taxes etc. all complete as per specification and direction of E.I.C.
Supplying all materials, labour, T&P and providing brick work with Fly ash bricks 25cmx12cmx8cm size having c.s. not less than 75kg/cm2 with dimensional tolerance ± 8% in c.m. (1:4)including watering,curing conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per specification and direction of E.I.C. a) In Foundation and Plinth(1:4)
Supplying all materials, labour, T&P and providing cement plaster on brick/stone work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per specification and direction of E.I.C.a) 20mm thick C.P with C.M. (1:4)
Supplying all materials, labour, T&P and providing cement punning including watering,curing, conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per specification and direction of E.I.C.
Supplying all materials, labour, T&P and providing cement flush pointing to brick masonary(1:3) including watering, curing, conveyance of all materials to worksite, payment of royality and taxes etc. all complete as per specification and direction of E.I.C
Supplying all materials, labour, T&P and providing rigid & smooth centering & shuttering for R.C.C.works including false work and dismantling them after casting including conveyance of all material, to worksite, payment of royalty, taxes etc. all complete as per specification and direction of E.I.C.
Supplying all materials, labour, T&P and providing M.S. reinforcement for R.C.C. works including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per specification and direction of E.I.C.
Supplying all materials, labour, T &P and providing C.C (1:1.5:3) using 12mm h.g. chips for R.C.C. works including hoisting, laying, watering, curing, conveyance of all materials to worksite, curing, conveyance of all materials to worksite, payment of royalty, taxes etc, all complete as per specification and direction of E.I.C.
Supplying all labour, materials T&P and fixing of 2" RCC baffle wall Pre-cast with C.C. (1:1.5:3) using 12 mm b.h.g. chips and fitted to septic tank as per P.H. Specification and direction of E.I.C.
Supplying all materials, labour, T&P Providing and fixing PVC Tee in all including supply of all jointging materials etc. all complete materials to as per specification and direction of E.I.C.a) 110mm x110mm x110mm PVC Tee
Supplying all materials, labour, T&P and providing pre-cast R.C.C. Manhole cover with C.C.(1:1.5:3) of 12 MM h.g. chips including conveyance of all materials to site after payment of royality and taxes etc.all complete as per PH.Specification and direction of E.I.C.
Supplying all labour, materials T&P and fixing of M.S.Step iron in 20mm dia M.S. Steel Bar and fixing into walls of septic tank duly embeded in C.C (1:3:6) all complete as per P.H. Specification and direction of E.I.C.
Filling F&P with excavated materials, including watering and ramming as per direction of E.I.C.
Supplying all materials, labour T&P and fixing Ceramic Tiles in floors on 25mm thick bed of cement mortar (1:1) joined with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per specification and direction of E.I.C.(a) 1St Floor
2nd Floor
Supplying all materials, labour T&P and fixing porcelain glazed tiles in dados skirting, on 12mm thick C.P. (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of E.I.C. (a) 1St Floor
2nd Floor
Supplying all materials, labour, T&P and providing two coats paint with water proofing cement paintover a coat of primer to wallsincluding all cost, conveyance and royalty etc. complete as per direction of E.I.C.
Supplying all materials, labour, T&P and fixing the Factory made single leaf rigid FRP(alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gelcoat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) impregnated with orthopthalic palyester resin. The thickness of the skins shall not be less than 1.50mm Expanded Polystyrone(EPS) structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material. Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mmx32mm and also necessary sal wood reinforcements for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, the sal wood reiforcements and the skins. The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters tested in conformation to IS: 4020-1998. The finish of door shutter will be plain colour white/ Ivory/ Beige/Light grey/ Mahogany/Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter.
Supplying all materials, labour, T&P and Factory made FRP(alternately called GRP) door frame of size 75mmx100mm fabricated using E-glass Chopped Strand Mat (CSM) U.V stabilised Inopthalic Gelcoat and impregnated with Inopthalic resin. The thickness of the GRP skins shall not be less than 2.00mm. The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The GRP frame shall be provided with wooden reinforcement on six locations for high screw holding capacity for for fixing metallic hold fast and shall be consolidated by filling with medium density foam/plaster of paris with fibre reinforcement, Six numbers of 260mm x 25mm x 5mm size 'S' shaped M.S flat hold fast shall be provided with the frame. The material and process for manufacturing the door frames shall conform to RV-TIFAC composites Design Centre's standards and specifications. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the E.I.C
Supplying all materials, labour T&P and cutting holes through brick/stone masonary walls for taking PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of E.I.C. a) 250 mm thick wall
(b)cutting hole through RCC Roof
Supplying all materials, labour T&P and fixing Wash Down Water Closet European type W.C. pan with Integral S or P trap to the floor with wooden plug and C.P.screws including jointing the trap with soil pipe in C.M.(1:1) etc. all complete as per specification & direction of E.I.C. a) E.W.C. with P trap plain including seat cover(Hindware/ Parrywear/ Cerra)
Supplying all materials, labour TP and fitting & fixing U-PVC ventilating pipes and fittings of the following O.D conforming to ISI No. 4985/2000 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method as per manufacturers specification, testing, e.w. in excavation in all kinds of soil and refilling of trenches as per direction of E.I.C. a) 110 mm dia U-PVC Pipes (4 Kgf/Cm2)
b) 110 mm dia U-PVC P Trap
c) 110 mm dia U-PVC S/J Door
c) 110 mm dia U-PVC D/J Door
d) 110 mm dia U-PVC Door Bend
e) 110 mm dia U-PVC Plain Bend
f) 110 mm dia U-PVC Plain Tee
g) 110 mm dia U-PVC Cowl
h) 110 mm dia U-PVC Offset
i) 125mm dia C.P grating
j) 75 mm dia U-PVC Pipes (4 Kgf/Cm2)
k)75 mm dia U-PVC Plain Bend
l)75 mm dia U-PVC Door Bend
m)75 mm dia U-PVC Plain Tee
Supplying all materials, labour T&P and fixing Wash basins with hole for pillar taps with C.I/M.S brackets painted white including holes in walls and making good the damages etc. all complete as per P.H specification and direction of E.I.C. a) 550mm x 400mm WHB with all Fittings.(Neycer/Cerra/ Parry ware).
b) Fixing of Pedestrial for W.H.B
Supplying all materials, labour T&P and fixing Mirror of superior glass mounted on PVC Frame and hanging the wall complete as per P.H specification and direction of E.I.C.a) 450mm x 350mm size mirror with Plastic Frame
Supplying all materials, labour T&P and fixing standard size C.P. towel rail / ring complete with c.p. brass brackets fixed to wooden plugs with c.p screws as per P.H specification and direction of E.I.C.a) 20 mm x 450 mm long C.P Towel rail
b) C.P. Towel Ring (St.)
Supplying all material, labour T&P and fitting,fixing of standard size Glass shelf with CP brass bracket and guard rails complete fixed to wooden plugs with CP screw as per specification and direction of E.I.C.
Supplying all materials, labour T&P and fixing standard size C.P. soap holder complete with c.p brass brackets fixed to wooden plugs with c.p screws as per P.H specification and direction of E.I.C.a) C.P.Soap Holder.
Supplying all material, labour, T&P and fixing bowl pattern urinal including connecting the urinal with west pipe by means of white lead list with chopped hemp etc. all complete as per direction of EIC.(Porcelinhalf stall Urinal Magnum Urinal)
15mm dia Urinal Spreader
Supplying all materials, labour, T&P and fixing glazed earth ware squatting plate size 600*300mm with integral longitudinal flushing pipe including embedding the plate in 25mm cement mortar (1:8) laid over 150mm CC. (1:5:10) using 40mm hg metal all complete as per specification of EIC.
Supplying all materials, labour T&P and fitting & fixing 10 Litres capacity low level cistern with a pair of cast iron of m.s. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float, c.p. brass handle, unions and couplings for connection with inlet, outlet and overflow pipe. 32 mm C.P flush bend 15mm PVC inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting inlet pipe with supply main etc. all complete as per specification and direction of E.I.C
Supplying all materials, labour T&P and costructing gully trap chamber of the following inside size with 8cm thick R.C.C. precast cover slab in c.c. (1:1 1.5:3) using 12 mm size h.g. chips foundation concrete (1:3:6) using 40 mm size h.g. metal on bed and arround trap Fly ash brick work in c.m. (1:6) in F&P and inside 12mm thick c.p (1:3) finished with a floating coat of neat cement including fixing 100mm size H.C.I gully trap and grating etc. all complete as per approved drawing, specification and direction of E.I.C.a) Inside size 250mm x 250mm gully trap Chamber
Supplying all materials, labour T&P and constructing Inspection chamber of the following sizes with c.c (1:3:6) using 40mm size h.g. metal on bed, Fly ash brick work in c.m (1:6), moulding and shaping the channel inside and benching with c.c. (1:1.1/2:3) using 12mm size h.g. chips 12mm thick c.p. (1:3) with punning to inside cement flush pointing (1:3) to outside R.C.C. cover slab in c.c. (1:11/2:3) using 12 mm size h.g. chips with R.C.C. m.h. cover, e.w. in excavation inall kinds of soil and refilling the cavity arround the chamber including watering, curing, conveyance of all materials to site payment of royalty, taxes etc. all complete as per approved specification and direction of the E.I.C. a) Inside size 760mm x 760mm x 460mm I.C.
Supplying all materials, labour T&P and constructing soak way pit of the following sizes with dry brick walling form bottom up to invert of inlet pipe and Fly ash brick work in c.m(1:6) for the remaining height at top, 12 mm thick c.p(1:4) inside and outside over masonary brickwork gravel packing in the rear of well steining R.C.C. cover slab in c.c (1:11/2:3) using 12mm size h.g. chips fitted with iron lifting handles including e.w. in open well excavation in all kinds of soil and refilling the cavity around the pit & painting the iron works, watering , curing, conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per approved drawing, specification and direction of E.I.C. a)1.20mtrs.dia x 2.0mtr.deep soak way pit
Supplying all materials, labour, T&P and constructing soak way pit of the following sizes with precast R.C.C rings joined loose gravel backing in the rear of well steining, precast R.C.C cover slab in c.c.(1:1.5:3) using 12mm size h.g. chips fitted with iron lifting handles including e.w. in open well excavation in all kinds of soil and refilling the cavity around the pit & painting the iron works, watering ,curing, conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per approved drawing, specification and direction of E.I.C.a) 0.91 mtr dia x 2.10 mtr. deep
Supplying all materials, labour, T&P and laying 110 mm dia U-PVC Pipe and aligning to requisite gradient inside the trench encasing all round of the pipe with c.c (1:3:6) using 4 CM size h.g. metal and CC(1:3:6) with 4CM size h.g. metal in the bed of the trench including lowering the pipes to the bed of the trench, earth excavation in trenches in all kinds of soil refilling the same in layer of 0.3 mtrs with watering and ramming, removing of surplus earth, testing of sewerage line including use of T&P as per PH Specification and direction of E.I.C.a) 110mm dia U-PVCPipe Sewerage line with all round encasing
Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor PVC Pipes conforming to ASTM-D-1785/89(sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor testing all complete as per specification and direction of E.I.C(a) 25mm dia C-PVC Pipe (Int.)
b) 25 mm dia PVC Pipe (ext.)
c) 20 mm dia C-PVC Pipe
d) 32 mm dia PVC Pipe (Ext)
e) 25 mm dia HDPE Pipe
Supplying all materials, labour, T&P and fitting & fixing brass /C.P. fittings of the following nominal bore with supply of all jointing materials etc. complete as per P.H. specification and direction of E.I.C.a) 25 mm dia F.W.V. (Good Quality)
b) 15 mm dia C .P (S.B.) Bib Cock (Good Quality)
c) 15 mm dia C .P (L.B.) Bib Cock(Good Quality)
d) 15 mm dia C .P Pillar Cock with swan Neck(Good Quality)
e) 15 mm dia C P conceled stop Cock(Good Quality)
f) 15 mm dia C .P Angle Stop Cock(Good Quality)
g) 15 mm dia C .P Two Way Bib Cock(Good Quality)
h) 15 mm dia C .P Health Faucet(Good Quality)
i) 15 mm dia C .P Extension Piece
j) 15 mm dia C .P flange
Supplying all materials, labour, T&P and cutting holes through brick/stone masonary works including making good the damages in CM (1:4) for taking PVC pipes and fittings etc.all complete as per direction of E.I.C.(a) 250mm thick wall
Supplying all material, labour,T&P and cutting grooves in pucca floors and wall for taking G.I /PVC pipe and making good the damage as per direction of EIC.
Supplying all materials, labour, T&P and fitting and fixing C.P. shower with 15 mm or 20 mm inlet with C. P. shower arm including polishing all complete as per P.H. specification and direction of E.I.C.
Supplying all materials, labour, T&P and fixing rotational moulded polyethylene cylindrical vertical waterstorage tank confirming to IS 12701- 1996 including cutting hole through the tank and fixing MS tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting the tank and placing the tank to the required position including all complete as per specification and direction of EIC.(including cost of FG Over Head Tank) a) 2000 Ltrs. Capacity .Over Head Tank.(2nd. Floor)
Supplying all materials, labour, T&P and construction of masonry staging with providing 1st class K.B. Brick work in C.M.(1:6) of 0.46mtr height in staging, 12 mm cement plaster in C.M (1:6), R.C.C. Beam of 0.25mx0.30mx3.18m in C.C (1:1.5:3) using 12mm size H.G.Chips including centering, shuttering, bending and binding of rod etc watering, curring, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.a) 2000 Ltrs. Capacity F.G.Over Head Tank.(2nd. Floor)
Recessed wiring to light point with 1.5 sq.mm FR PVC insulatedsingle core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5Amp, 250 V piano type modular switch ISI marked and ceiling rose ISI marked mounted on MS box having front Modular base & cover of suitable size , MS box with 1 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels /HPL/ V Guard )-- Group A
-do- Group B
-do- Group C
Recessed wiring to Fan Point in... -do- Group B
Recessed wiring to Call Bell Point in... -do- Group C
Recessed wiring to Exhaust Fan Point in-do- Group B
S/F of fan hook S type made of 16 mm MS rod for fixing in the Existing RCC Roof.
S/F of Angle holder replacing Ceilling Rose
S/F of 5A. Modular Switch & 5A. Modular Socket outlet of ISI marked on existing board
S/F of extension board of 6 modular Metal box with modular base & cover in recess including providing and fixing of 2 nos of 3pin 5/6amp modular socket out let & 2 nos of 5/6 amp piano type modular switch, connection, painting etc as required.
S/F of Power point with 4 modular metal box with modular base & cover in recess including providing and fixing of 5 pin 15/16 amp. piano type Modular switch & Socket, connection, painting etc as required
S/F of computer board consisting of 3 nos of 5amp modular plug and modular switch complete with wiring on 12 modular M.S. box with modular cover.
S/F of 1 no of 5 pin 15/16 amp. Socket , 1 no of switch & 1 no of 15/16A top with modular mini MCB, in 6 modular box with cover with connection, painting etc as required for Inverter connection
S/F of 18 SWG Modular metal box of following sizes (Nominal size) in recess with suitable size of Modular base & cover in front including cutting the wall and making good the same in case of recessed conduit as required. ---2 Modular box with base & cover
4 Modular box with base & cover
8 Modular box with base & cover
12 Modular box with base & cover
Wiring for circuit / sub-main wiring along with earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20mm dia non metalic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required (Make of wire - Finolex/L&T/Anchor/Havels/V-guard) ---2x1.5+1x1.5 (1.8.1)
Inverter wiring (1x2.5smm) Copper wire (1.19.11a)
S/F of 'C' series SP MCB of 10 to 32A amp rating (As per direction of engineer in charge) 440Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required without MCB box (Make : Legrand / Hager / Scheider / Seimens)
S/F of 'C' series 4P MCB of 63A amp rating (As per direction of engineer in charge) 440Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required without MCB box (Make : Legrand / Hager / Scheider / Seimens)
S/F of 'C' series DP MCB of 16 amp rating (As per direction of engineer in charge) 440Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required without MCB box (Make : Legrand / Hager / Scheider / Seimens)
S/F of 'C' series 4P MCB of 32A amp rating (As per direction of engineer in charge) 440Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required without MCB box (Make : Legrand / Hager / Scheider / Seimens)
S/F of 4Way (8+12) TPN Double Door Distribution Board ISI marked complete with all accessories and connection etc. as required (Make : Legrand / Hager / Scheider / Seimens)
Supply & laying 8 SWG Cu wire in recess for loop earthing as required (3.18)
S/F of Cu .Earth Plate Earthing 600 mm x600mmx3.15mm with Salt & Charcoal for Earth electrode (3:5)+(3.6)
Supply and fixing of 230mm Exhust fan with all accessories and connections (Make:Usha-Aero Clean Plus DBB/Crompton- Trans Air 12" reversiable /Havells-Venti Air DS (HS)/Anchor- Anmol delus R/Orient-Power Flow DBB// Pollycab -Fresh on DBB )
S/F of Call bell/Buzzer(Ding dong type) ISI marked suitable for DC/AC single phase 230 volts complete as required. (1.30)
S/F of 18-25Watt L.E.D Tube light fitting with all accessories and connections (Make:HPL/ Havells/PAC/Crompton/Polycab)
Supply and fixing of 1200mm A.C. Ceiling fan (5 star) 28 watt BLDC with all accessories and connections with out fan regulator (Make:Usha-Techinix ISI /Crompton- Energion Groove/Havells-Efficiencia Neo/ Anchor- Eco Breeze Urban/Orient-Eco Tech Supreme/ Pollycab -Affeciente Neo )
S/F step type modular fan regulator
Supply and fixing of 60 Watt Single LED Street Light Fitting with LED & Electronic driver with all accessories and connections ( Make- Crompton/Phillips/HPL/Polycab/Havells )
S/F of 10w Watt LED Bulb
S/F of 1.5 T 3 Star Inverter Model Split Type AC Machine (Make- Hitachi/Blue Star/Carrier/Daikin/LG/Mitsubishi/O-General)
S/F of 4KVA Automatic Voltage Stabilizer(130-300V), Make-Microtech/V-Guard
S/F of PVC hard drainage pipeline system.
6sqmm 3 core copper round cable
S/F of 15Amp Top
S/F of extra copper cooling pipe with insulation packing and round flexible cord for power supply
S/F of 2000VA/24V Invertor machine with 2 nos 180Ah tall tubular Battery including Trolly (Make-Luminous /microtek/v-guard)
S/F of 18W LeD Squre (12"×12") LSDSMN-12W-WW with surface Panel rings (Havels/crompton/philips/panasonic)
S/F of 15A socket on 2Modular Board board for A.C
S/F of 25A Moter Starter switch for A.C (Make: Havells / Anchor/Le-Grand)
Supply & fixing of 100 A TPN Panel board 1. 100A MCCB (Make : Legrand / Hager / Scheider / Seimens)-1No. 2. TPN Busbar-1set with DC Gland aluminium armoured cable 3. 4Pole Spreaders link (63A-200A) 4. 63Amp 4P Changeover-1No. 5. Digital Volt meter & Ameter three phase 6. All accesories & Connection (Rating & Danger borad)
Provision for external EI work with service connection for power supply
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_2.pdf
PDF • 6.70 MB
Tendernotice_1.pdf
PDF • 1.95 MB
BOQ_579509.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid