| 1 | L1₹17 LAccepted-AOC F IA 24 4210 CO JAYKRISHNAPUR P O BEGAMPUR DIST HOOGHLY | BEGAMPUR | HOOGHLY | WEST BENGAL | L1 | Accepted-AOC AOC ISSED | |
| 2 | L2₹17.4 L+₹40,000 (2.35%)Rejected-Finance 104 RASTRA GURU AVENUE DUM DUM NAGERBAZAR KOLKATA 700028 | KOLKATA | KOLKATA | WEST BENGAL | 700028 | L2 | Rejected-Finance that the bid is not L1 | |
| 3 | L3₹17.4 L+₹45,000 (2.65%)Rejected-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | L3 | Rejected-Finance that the bid is not L1 |
| Sl No | Description | Qty | Unit | SNOWLINE ENGINEERS L2 | BLUE STAR LIMITED L3 | P. M. COOLING AND ENGINEERING CO L1 |
|---|---|---|---|---|---|---|
| 1.00WALK-IN-COOLER-1 SITC of Air Cooled Refrigeration Unit for WIC - - 2 Sets Refrigerant -- R-404A/R407/R410a MODEL: RUAHI-1514 + RUAHOP-1514 or equivalent MAKE: BLUE STAR/HITACHI/CARRIER/VOLTAS incl 60mm thick PUF insulated panels for ceiling & walls of WIC-PPGI [Cyclopentane PUF Panel] - 1 Set incl 60mm thick PUF Panel with Marine Ply & Aluminum Checkered Plate for floor of WIC- [Cyclopentane PUF Panel] - 1 Set incl PUF insulated Hinge Door of size: 34” x 78” x 60 mm thick with View Port [Size- 12”x12”] of WIC - 1 Set Approved Microprocessor based Digital Temperature indicator cum Controller (Model: BSL 52) - 2 Sets consists of Data Logger with Necessary software- placed inside the WIC (Model: T-LOG) - 1 Set | ||||||
| 1.10incl MS Powder Coated Racks - 10 Sets incl approved - PVC Strip Curtain - 1 Set incl approved high temp- low temp notification Alarm - 2 Sets Supply of WIC Lighting (LED) - 3 Sets Supply of Pre Fabricated CDU Base - 2 Sets Copper piping and electrical cabling between IDU and CDU - 2 Sets Suction line insulation with Nitrile Rubber - 2 Sets DANFOSS / Equivalent make Refrigeration Controls comprising of the following. - - 2 Sets a) Thermostatic Expansion Valves b) Filter Driers c) Temperature Indicator cum Controllers First Charge of refrigerant and Compressor Oil - 2 Sets Complete Supports for Equipments - 2 Sets | ||||||
| 1.20 | PVC Drain Pipes to drain out the Condensate from the Evaporator outlet to the nearest Drain Pit - 2 Sets
Labour Charges for Erection, Testing, Commissioning and Fine tuning the
Refrigeration System - 2 Sets
Labour Charges for Erection, Testing, Commissioning of Panel Room and Door - 1 Set | 1 | Item. | 9,38,000 ₹9,38,000 | 9,40,000 ₹9,40,000 | 9,00,000 ₹9,00,000 Lowest |
| 2.00WALK-IN-COOLER-2 SITC of Air Cooled Refrigeration Unit for WIC - - 2 Sets Refrigerant -- R-404A/R410/R407 MODEL: RUAHI-1014 + RUAHOP-1014 MAKE: BLUE STAR/HITACHI/CARRIER/VOLTAS incl 60mm thick PUF insulated panels for ceiling & walls of WIC-PPGI [Cyclopentane PUF Panel] - 1 Set incl 60mm thick PUF Panel with Marine Ply & Aluminum Checkered Plate for floor of WIC- [Cyclopentane PUF Panel] - 1 Set incl PUF insulated Hinge Door of size: 34” x 78” x 60 mm thick with View Port [Size- 12”x12”] of WIC - 1 Set Approved Microprocessor based Digital Temperature indicator cum Controller (Model: BSL 52) - 2 Sets approved- Data Logger with Necessary software- placed inside the WIC (Model: T-LOG) - 1 Set | ||||||
| 2.10approved MS Powder Coated Racks - 8 Sets approved - PVC Strip Curtain - 1 Set approved high temp- low temp notification Alarm - 2 Sets Supply of WIC Lighting (LED) - 2 Sets Supply of Pre Fabricated CDU Base - 2 Sets Copper piping and electrical cabling between IDU and CDU - 2 Sets Suction line insulation with Nitrile Rubber - 2 Sets DANFOSS / Equivalent make Refrigeration Controls comprising of the following. - - 2 Sets a) Thermostatic Expansion Valves b) Filter Driers c) Temperature Indicator cum Controllers | ||||||
| 2.30 | First Charge of refrigerant and Compressor Oil - 2 Sets
Complete Supports for Equipments - 2 Sets
PVC Drain Pipes to drain out the Condensate from the Evaporator outlet to the nearest Drain Pit - 2 Sets
Labour Charges for Erection, Testing, Commissioning and Fine tuning the
Refrigeration System - 2 Sets
Labour Charges for Erection, Testing, Commissioning of Panel Room and Door - 1 Set | 1 | Item | 8,02,000 ₹8,02,000 | 8,05,000 ₹8,05,000 | 8,00,000 ₹8,00,000 Lowest |
| 3.00Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Libilities period for 01 year from the date of completion of work)(Rate should be quotated including all taxes and duties) | ||||||
Tender Value
Refer Docs
EMD Value
₹35,000
Closing Date
28 Mar 2022, 1:00 pmClosed
EE II KNHED PW Dte.
KIT Building Annex, 4thFloor,P-16, India Exch. Place Extn., Kolkata -700073
Construction of Modular Cold Chain Room Walk in Cooler In Pharmacy at Ground Floor at MCH Building under Medical College and Hospital Kolkata Electrical Work AC Work
2022_PWDE_368718_1
WBPWD/EEII/KNHED/NIQ-130/21-22
Open Tender
A/C ORG
Item Rate
60 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹35,000
23 Sept 2026
3 Mar 2022
30 Mar 2022
5 Mar 2022
28 Mar 2022
5 Mar 2022
Amount
WALK-IN-COOLER-1 SITC of Air Cooled Refrigeration Unit for WIC - - 2 Sets Refrigerant -- R-404A/R407/R410a MODEL: RUAHI-1514 + RUAHOP-1514 or equivalent MAKE: BLUE STAR/HITACHI/CARRIER/VOLTAS incl 60mm thick PUF insulated panels for ceiling & walls of WIC-PPGI [Cyclopentane PUF Panel] - 1 Set incl 60mm thick PUF Panel with Marine Ply & Aluminum Checkered Plate for floor of WIC- [Cyclopentane PUF Panel] - 1 Set incl PUF insulated Hinge Door of size: 34” x 78” x 60 mm thick with View Port [Size- 12”x12”] of WIC - 1 Set Approved Microprocessor based Digital Temperature indicator cum Controller (Model: BSL 52) - 2 Sets consists of Data Logger with Necessary software- placed inside the WIC (Model: T-LOG) - 1 Set
incl MS Powder Coated Racks - 10 Sets incl approved - PVC Strip Curtain - 1 Set incl approved high temp- low temp notification Alarm - 2 Sets Supply of WIC Lighting (LED) - 3 Sets Supply of Pre Fabricated CDU Base - 2 Sets Copper piping and electrical cabling between IDU and CDU - 2 Sets Suction line insulation with Nitrile Rubber - 2 Sets DANFOSS / Equivalent make Refrigeration Controls comprising of the following. - - 2 Sets a) Thermostatic Expansion Valves b) Filter Driers c) Temperature Indicator cum Controllers First Charge of refrigerant and Compressor Oil - 2 Sets Complete Supports for Equipments - 2 Sets
PVC Drain Pipes to drain out the Condensate from the Evaporator outlet to the nearest Drain Pit - 2 Sets Labour Charges for Erection, Testing, Commissioning and Fine tuning the Refrigeration System - 2 Sets Labour Charges for Erection, Testing, Commissioning of Panel Room and Door - 1 Set
WALK-IN-COOLER-2 SITC of Air Cooled Refrigeration Unit for WIC - - 2 Sets Refrigerant -- R-404A/R410/R407 MODEL: RUAHI-1014 + RUAHOP-1014 MAKE: BLUE STAR/HITACHI/CARRIER/VOLTAS incl 60mm thick PUF insulated panels for ceiling & walls of WIC-PPGI [Cyclopentane PUF Panel] - 1 Set incl 60mm thick PUF Panel with Marine Ply & Aluminum Checkered Plate for floor of WIC- [Cyclopentane PUF Panel] - 1 Set incl PUF insulated Hinge Door of size: 34” x 78” x 60 mm thick with View Port [Size- 12”x12”] of WIC - 1 Set Approved Microprocessor based Digital Temperature indicator cum Controller (Model: BSL 52) - 2 Sets approved- Data Logger with Necessary software- placed inside the WIC (Model: T-LOG) - 1 Set
approved MS Powder Coated Racks - 8 Sets approved - PVC Strip Curtain - 1 Set approved high temp- low temp notification Alarm - 2 Sets Supply of WIC Lighting (LED) - 2 Sets Supply of Pre Fabricated CDU Base - 2 Sets Copper piping and electrical cabling between IDU and CDU - 2 Sets Suction line insulation with Nitrile Rubber - 2 Sets DANFOSS / Equivalent make Refrigeration Controls comprising of the following. - - 2 Sets a) Thermostatic Expansion Valves b) Filter Driers c) Temperature Indicator cum Controllers
First Charge of refrigerant and Compressor Oil - 2 Sets Complete Supports for Equipments - 2 Sets PVC Drain Pipes to drain out the Condensate from the Evaporator outlet to the nearest Drain Pit - 2 Sets Labour Charges for Erection, Testing, Commissioning and Fine tuning the Refrigeration System - 2 Sets Labour Charges for Erection, Testing, Commissioning of Panel Room and Door - 1 Set
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Libilities period for 01 year from the date of completion of work)(Rate should be quotated including all taxes and duties)
SNOWLINE ENGINEERS
BLUE STAR LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .