| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.0 LAccepted-AOC NURSERY SCHOOL 1 SECTOR 33 SUNCITY KURUKSHETRA ROAD KAITHAL 136027 HARYANA | KAITHAL | KAITHAL | HARYANA | 136027 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹45.3 L+₹2.3 L (5.41%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹45.9 L+₹2.8 L (6.62%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹46.3 L+₹3.3 L (7.63%)Rejected-Finance 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹46.4 L+₹3.3 L (7.78%)Rejected-Finance RCP GURUDWARA ROAD WARD NO 29 SURATGARH SRI GANGANAGAR 335804 | SURATGARH | SRI GANGANAGAR | RAJASTHAN | 335804 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹46.7 L
EMD Value
₹93,400
Closing Date
11 Oct 2022, 6:00 pmClosed
GE ARMY SURATGARH
SURATGARH MIL STN
Special repair for replacement of LT panel, lighting conductor, provision of 01 x LED high mast lightning work and lightning conductor under GE (Army) Suratgarh at Suratgarh Mil Stn
2022_MES_548513_2
GE (A) SOG - 44/22-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SURATGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ARMY SURATGARH
₹93,400
Yes
7 Nov 2022
20 Sept 2022
13 Oct 2022
20 Sept 2022
11 Oct 2022
27 Sept 2022
Amount
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable and water supply / sewage pipe line etc. in soft / loose soil & getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge.
All as per serial item No. 1 here-in-above but depth exc 1.5 mtr & not exc 3mtr
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of poles etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engineer-in-charge
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation of poles, filling & mass concrete including necessary form work complete all as specified and directed by Engineer-in-charge .
M & L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation for stays & mass concrete including necessary form work and fair finishing complete all as specified and directed by Engineer-in-charge
S&F aluminium strip of size 25x3.00 mm with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified and directed by Engineer -in-Charge.
S&F in repair aluminium strip of size 25x3.00 mm with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified and directed by Engineer -in-Charge.
S&F test point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 Nos, 8mm dia, 25 mm long hexagonal screw complete all as specified and directed by Engineer -in-Charge.
S&F in repair test point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 Nos, 8mm dia, 25 mm long hexagonal screw complete all as specified and directed by Engineer -in-Charge.
S&F air termination, single pointed aluminium rod 12 mm dia single pointed 300 mm long complete all as specified and directed by Engineer -in-Charge.
S&F in repair air termination, single pointed aluminium rod 12 mm dia single pointed 300 mm long complete all as specified and directed by Engineer -in-Charge.
M&L Cast Iron / Pressed steel terminal boxes 100mm x 100mm x 60mm deep for accomadate the test point terminal block with 3mm thick plastic laminated sheet cover complete all as specified and directed by Engineer -in-Charge.
M&L in repair Cast Iron / Pressed steel terminal boxes 100mm x 100mm x 60mm deep for accomadate the test point terminal block with 3mm thick plastic laminated sheet cover complete all as specified and directed by Engineer -in-Charge.
S&F galvanized iron strip of size 32 mm x6mm to be used as down conductor for lighting protection and to arrange ring main circuit for earth pit complete all as specified and directed by Engineer -in-Charge.
S&F in replacement galvanized iron strip of size 32 mm x6mm to be used as down conductor for lighting protection and to arrange ring main circuit for earth pit complete all as specified and directed by Engineer -in-Charge.
Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 25 sq mm 4 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
Supplying, jointing and testing heat shrinkable type, in / out door, end termination jointing kit, suitable for cable of size 25 to 50 Sqmm, 3.5 core aluminium conductor 1100 Volts including making connections complete all as specified and directed by Engineer-in-Charge.
All as per item No 19 above but suitable for cable of size 70 sqmm to 120 sqmm.
All as per item No 19 above but suitable for cable of size 150 sqmm to 185 sqmm.
All as per item No 19 above but suitable for cable of size 240 sqmm to 300 sqmm.
S&F in replacement PVC insulated stranded copper conductor, 1100 volts grade, 95sqmm single core size of ISI marked connection from starter panel to motor terminal complete all as specified and directed by Engineer-in-Charge.
S&F in replacement PVC insulated stranded copper conductor, 1100 volts grade, 25sqmm single core size of ISI marked connection from starter panel to motor terminal complete all as specified and directed by Engineer-in-Charge.
Supply only LED flood light of 170 watt with high pressure die cast housing with lens with 6500K complete (including LED, drive and internally prewired) with on board / external 10 KV SPD. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP 65 protection as per IS 10322-1982 (part-I) with latest amanedments and input voltage range 140-300V AC, frequency 50-60 Hz, P.F should be more than 0.9. The efficiency of LED luminaries system shall be more than 110 lumens per watt and FRLSH cable PVC insulated stranded copper conductor, 1100 volts grade, 2.5 sqmm x 3 core of ISI marked for light to ceiling rose complete including arrangement of mounting for street light as required at site complete all as specified and directed by Engineer-in-charge.
Supply, install, commissioning of 15 metre high 20 sided polygon highmast lighting system fabricated out of BS-EN 10025 or equivalent 355 Mpa material in two sections, hot dip galvanised (single dip) internally & externally having uniform coating thickness of 85/ 65 micron for bottom & top section respectively as per BS 729 and with one longitudinal weld and having no circumferential weld suitable for wind velocity of 180 Km/hr as per IS -875 (Part-3) duly provided with accessories like head frame, steel wire rope 6mm dia (7/19 construction with central core SS) trailing cable double drum winch, galvanised lantern carriage arrangement suitable for 09 luminaires symmetrically and end finial. The mast shall have an integral power tool motor (1HP, 3 Ph, 415 volts) installed inside the base compartment for its operation as per manufacturers design/ details complete all as specified and directed by Engineer-in-Charge. Make : Bajaj / Philips / Crompton / GE or equivalent in makes mentioned in Appendix 'A' here-in-after of 15 M height suitable for design condition specified above. Highmast light includes the following :- (i) Supply, and fixing of foundation bolts manufactured from special steel alongwith nuts, washers, anchor plates and templates etc as required as manufacturers recommendations suitable for design life not less than 25 years. (ii) Erection and commissioning of high mast with the help of suitable equipments and wiring of luminaries with all all copper conductor, cable of suitable size & providing flexible steel conduit pipe of ¾"mm dia for protection of cable.
Contd/-… item No 26 (iii) Drawing, design and casting of suitable shallow foundation with RCC M-25 mix concrete for high mast considering the safe bearing capacity of soil as 10 tonne/ Sqm at 2.00 metre depth duly approved by GE - 01 Job (iv) Casting of suitable foundation with RCC M-25 mix concrete for panel as per manufacturers recommendations. (v) Supply and fix integral aviation obstruction light comprising of aluminium housing with polycarbonite enclosures - LED type - 02 Nos Make : Bajaj Cat No. BGAV 302 LED / Crompton Greaves / Philips/ GE or equivalent in makes mentioned in Appendix 'A' here-in-after. (vi) Supply and installaton of control panel (KIOSK) (out door, double door) 63 Amps tripple pole & neutral (TPN) MCB incomer housing suitable for circuit for operation of mast including suitable control circuit for power tool motor complete as per manufacturer recommendations - 01 Job (vii) All necessary Excxavation and earthwork in any type of soil including returning, filling and removal of surplus soil to distance not exceeding 50 metre completed all as specified and directed by Engineer-in-Charge. (viii) Contractor shall submit Manufacturer guarantee certificate for a period not less than 05 years.
Suppyling, installing, testing and commissioning in replacement of factory made outdoor type LT cubical panel board suitable for operation on 415 volts, 3 phase, 4 wire 50Hz supply system inlcluding bus bar chamber in centre ( vertically) and cable alley either side, outer shell shall be made out of 3.15mm thick CRCA sheet duly powder coated coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back, outer door shall be provided with double door fix with hinges and locking arrangements etc suitables to accomodate the following mentioned fittings and inner shell shall be made out of 2mm thick CRCA sheet duly powder coated & compartmentalized for each control gear including front openable single door with half nob type locking, inlcuding provision for taking out incoming and outgoing cables duly marked with reveted letter plated of appropriate size for each feeder / block cable, danger board, detachable plate at bottom for cable entry etc including double compression type cable gland with bottom frame made out of angle iron 50mm x 50mm x 6mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body with and including following accesories :-
All as per item No 27 above but comprising of following accessories :- Incoming (a) 1200 Amps aluminium bus bar including Neutral and three phase - 01 Set (b) 800 Amps, 50 KA, 4 Pole, 415 Volts (Mannually drawout type with microprocessor based relay comprising with earth fault, overload and short circuit)- 01 No Outgoing (a) MCCB 630 Amps, 50 KA, 4 Pole, 415 Volts, thermal Magnetic release type - 01 No (b) MCCB 200 Amps, 50 KA, 4 Pole, 415 Volts, thermal Magnetic release type - 01 No (c) MCCB 160 Amps, 50 KA, 4 Pole, 415 Volts, thermal Magnetic release type - 02 No (d) MCCB 100 Amps, 50 KA, 4 Pole, 415 Volts, thermal Magnetic release type - 01 No (e) MCCB 63 Amps, 25 KA, 4 Pole, 415 Volts, thermal Magnetic release type - 01 No (f) Digital Voltmeter and Ampere meter flush type 96x96mm inlcuding CTs suitable size - Each Seprately (g) Internal all links & control cable and indicators - set of three
All as per item No 27 above but comprising of following accessories :- Incoming (a) 600 Amps aluminium bus bar including Neutral and three phase - 01 Set (b) MCCB 400 Amps, 50 KA, 4 Pole, 415 Volts, thermal Magnetic release type - 01 No Outgoing (a) MCCB 200 Amps, 36 KA, 4 Pole, 415 Volts, thermal Magnetic release type - 03 No (b) Digital Voltmeter and Ampere meter flush type 96x96mm inlcuding CTs suitable size - Each Seprately (c) Internal all links & control cable and indicators - set of three
All as per item No 27 above but comprising of following accessories :- Incoming (a) 400 Amps aluminium bus bar including Neutral and three phase - 01 Set (b) MCCB 250 Amps, 36 KA, 4 Pole, 415 Volts, thermal Magnetic release type - 01 No Outgoing (a) MCCB 63 Amps, 25 KA, 4 Pole, 415 Volts, thermal Magnetic release type - 08 No (b) Digital Voltmeter and Ampere meter flush type 96x96mm inlcuding CTs suitable size - Each Seprately (c) Internal all links & control cable and indicators - set of three
All as per item No 27 above but comprising of following accessories :- Incoming (a) 300 Amps aluminium bus bar including Neutral and three phase - 01 Set (b) MCCB 200 Amps, 36 KA, 4 Pole, 415 Volts, thermal Magnetic release type - 01 No Outgoing (a) MCCB 63 Amps, 25 KA, 4 Pole, 415 Volts, thermal Magnetic release type - 06 No (b) Digital Voltmeter and Ampere meter flush type 96x96mm inlcuding CTs suitable size - Each Seprately (c) Internal all links & control cable and indicators - set of three
All as per item No 27 above but comprising of following accessories :- Incoming (a) 250 Amps aluminium bus bar including Neutral and three phase - 01 Set (b) MCCB 160 Amps, 36 KA, 4 Pole, 415 Volts, thermal Magnetic release type - 01 No Outgoing (a) MCCB 63 Amps, 25 KA, 4 Pole, 415 Volts, thermal Magnetic release type - 04 No (b) Digital Voltmeter and Ampere meter flush type 96x96mm inlcuding CTs suitable size - Each Seprately (c) Internal all links & control cable and indicators - set of three
All as per item No 27 above but comprising of following accessories :- Incoming (a) 600 Amps aluminium bus bar including Neutral and three phase - 01 Set (b) MCCB 400 Amps, 36 KA, 4 Pole, 415 Volts, thermal Magnetic release type - 01 No Outgoing (a) MCCB 250 Amps, 36 KA, 4 Pole, 415 Volts, thermal Magnetic release type - 01 No (a) MCCB 160 Amps, 36 KA, 4 Pole, 415 Volts, thermal Magnetic release type - 01 No (a) MCCB 63 Amps, 25 KA, 4 Pole, 415 Volts, thermal Magnetic release type - 03 No (a) MCB 40 Amps, Single Pole & neutral 240 Volts, 16 KA, ‘C’ Curve, - 05 No (b) Digital Voltmeter and Ampere meter flush type 96x96mm inlcuding CTs suitable size - Each Seprately (c) Internal all links & control cable and indicators - set of three Note for srl item No 18 to 24 :- Cost of PCC, excavation and earth work is included in the unit rate of this item nothing extra shall be paid on this account.
S&F three phase automatic street light switch suitable for 5 KW load complete with Infrared sensor based NATURE SWITCH for automatic switching of street / security lights with three number two pole power contractors 40 Amps (Type - MU40-2P, Cs90119) with coil voltage 220 / 240 V and incoming MCBs single pole - 03 Nos, outgoing MCBs single pole - 03 Nos of rating 32 Amps & circuit wiring with single core multi stranded of size 10 Sqmm. Lighting switch operation should be based on natural light lux level. Required illuminance level for switching ON is < 30 Lux and for switching OFF > 10 Lux. The sensor should also have part night operation facility for 4,5,6,........11 & 12 hours. The sensor along with suitable power contactor (S), Incoming -outgoing MCB's should be enclosed in a Rust proof, electric shock proof, termite proof and FR grade thermoplastic polycarbonate enclosure with hinged lid confirming to IP66 protection class 2. The circuit should also have provision for manual operation (i.e. sensor By-pass option). The enclosure sould be mounted on 40mm x 40mm x 5mm angle iron structure and the structure height minimum 600mm and must be grouted in PCC (1:2:4) type B-1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm complete all as specified and directed by Engineer in charge. Make :- KAKATIYA ENERGY SYSTEM PVT LTD (Swadeep 02EC3KW1P) or equivalent in makes mentioned in Appendix 'A' here-in-after
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with required number of mild steel clamp made out of 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade of length 2.25 metre and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mmthick pre-cast RCC (1:2:4) type B-0 cover with 40mm x 40mm x 3mm MS angle iron frame, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed by Engineer-in-charge. Notes :- (i) GI strip upto earth test point/equipment is included in this item. (ii) Outer edge of earth pit shall be 1.5 metre away from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement for earth pit cover shall be 1 kg .
All as per item No 35 above but including taking old earthing
M&L for earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3.50m length buried directly and preferably vertically in ground with top edge not less than 0.25m below ground level, pipe surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by electric welding and connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with required Nos of mild steel clamp made out 25mm x 3mm flat iron, PCC chamber in cement concrete (1:2:4) type B-1 and 40mm thick RCC cover, excavation & earth work complete all as shown in electrical plate No. 2 of MES Schedule Part-I of SSR-2009 complete all as specified and directed by Engr-in-charge. Note:- (i) GI strip upto earth test point/equipment is included in this item. (ii) Minimum weight of reinforcement for RCC cover shall be 1 KG. (iii) Pipe electrode shall be tapered at the bottom and provide with 12mm holes (staggered) at 75mm centre to centre up to 2 meter height.
M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge Note: - For payment purpose thickness after punning shall be measured.
M & L for brick protection with old size sub class 'B' bricks laid flat, length of bricks across the route of underground cable complete all as specified and directed by Engineer-in-Charge.
S&F Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account..
S&F in repair 50mm bore galvanized steel tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F steel tubular swaged pole 11 meter long type 410 SP-55 and including two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.5 metre height from PCC coping and applying two coats of aluminium paint to remaining portion of pole, clamps etc and marking pole number with synthetic enamel paint black colour in 80mm high letters over 150mm x 230mm yellow base made from synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. Note :- Earthwork, PCC in foundation & coping shall be meaasured and paid saperately under respective items of BOQ.
M&L for GI wire 3.15 or 4mm dia including stretching on LT poles as contineous earth wire or for guarding and cradles including binding as required complete all as specified and directed by Engineer-in-Charge. Note: -(i) For payment purpose, weight of galvanised wire shall only be considered. Clamps, eye hooks where provided shall be measured and paid for separately . -------------------------------------------------------------------- Note :- A sum of Rs. 245495/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 28 (Schedule of Credit) of Tender documents.
BHADU BUILDERS
Gupta Suppliers
Singla Electricals
SRI SAI CONSTRUCTION COMPANY
GURDEEP SINGH AND COMPANY
M/s Rohit Construction Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .