Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 CrAccepted-AOC | ₹31.5 Cr | L1 | Accepted-AOC The rates quoted by L1 is found competitive and reasonable |
| 2 | L2₹33.9 CrRejected-Finance | ₹33.9 Cr | L2 | Rejected-Finance L2 |
| 3 | L3₹35.1 CrRejected-Finance | ₹35.1 Cr | L3 | Rejected-Finance L3 |
| 4 | L4₹36.4 CrRejected-Finance | ₹36.4 Cr | L4 | Rejected-Finance L4 |
| 5 | L5₹36.8 CrRejected-Finance | ₹36.8 Cr | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹48.4 L
Closing Date
8 Sept 2022, 3:00 pmClosed
Shri G I WADHWA Chief Executive
CCE R AND D WEST PASHAN PUNE
CREATION OF INTEGRATED NON-DESTRUCTIVE EVALUATION COMPLEX (INDEC) FOR HD 1.1 CLASS OF EXPLOSIVE SYSTEM AT HEMRL,PUNE
2022_DRDO_704401_1
CCE (R AND D)W/C-2/20451/HEMRL/PLG
Limited
Civil Works
640 days
HEMRL PUNE
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,000
Yes
CCE R AND D WEST
₹48.4 L
Yes
CCE R AND D WEST PASHAN PUNE
18 Jan 2023
4 Aug 2022
9 Sept 2022
5 Aug 2022
8 Sept 2022
13 Aug 2022
5 Aug 2022 - 7 Aug 2022
10 Aug 2022
Amount
SUBHEAD- I- SITE DEVELOPMENT
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
SUBHEAD - II EARTH WORK AND EXCAVATION
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.
Ordinary rock
Hard rock (blasting prohibited)
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.
Ordinary rock
Hard rock (blasting prohibited)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
All kinds of soil
Ordinary or hard rock
Supplying and filling in plinth with River sand / M-Sand under floors, including watering, ramming, consolidating and dressing complete
Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge.
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for Pre & Post -CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Treatment of soil under floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor. With Chlorpyriphos/Lindane E.C. 20% with 1% concentration.
Credit For Hard Rock
SUBHEAD- III PLAIN AND REINFORCED CEMENT CONCRETE WORK.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:
1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
Extra for providing and mixing water proofing material in cement concrete work @ 1 kg per 50kg of cement.
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
Extra for addition of synthetic Polyester triangular fibre of length 12mm, effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in cement concrete/RCC/Flooring/water retaining structures by using 125gms of synthetic Polyester triangular fibre for 50 Kg cement used as per directions of Engineer-in-Charge.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
All works upto plinth level
Concrete of M25 grade with minimum cement content of 330 kg /cum
Concrete of M30 grade with minimum cement content of 350 kg /cum
All works above plinth level upto floor V level
Concrete of M25 grade with minimum cement content of 330 kg /cum
Concrete of M30 grade with minimum cement content of 350 kg /cum
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all height & level.. Thermo-Mechanically Treated bars. Fe-500D
Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform
Shelves (Cast in situ)
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Stairs, (excluding landings) except spiral-staircases
Edges of slabs and breaks in floors and walls Under 20 cm wide
Weather shade, Chajjas, corbels etc., including edges
Modular formwork : Centering and shuttering including strutting, propping etc. and removal of form for walls of any thickness, level and height / depth etc. complete using modular form work of approved make for Retainning wall / slab etc. all complete as per directed by Engineer-in-charge. The surface shall be exposed and no plaster shall be done over the RCC surface.
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand/ M-Sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand / M-Sand ).
SUBHEAD - IV BRICK MASONRY WORK .
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) : With F.P.S.(non modular) bricks
Providing brick work with non modular fly ash bricks conforming to IS:12894,class designation 10 average compressive strength in super structure above plinth level upto floor V level in: Cement Mortar 1:6 ( 1 cement : 6 coarse sand )
Half brick masonry with non modular fly ash bricks pf class designation 10,conforming to IS:12894,in super structure above plinth and upto floor V level. Cement Mortar 1:4 ( 1 cement : 4 coarse sand )
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
SUBHEAD - V : PLASTERING AND SURFACE TREATMENT
Providing of 6mm cement plaster of mix in all surface with cement mortar 1:3 (1 cement : 3 fine sand / M-Sand ) at all levels
Providing of 12 mm cement plaster of mix in all surface with cement mortar 1:6 (1 cement : 6 fine sand / M-Sand ) at all levels.
15 mm cement plaster on the rough side of single or half brick wall.1:6(1 cement:6 coarse sand)
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20 mm cement plaster
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers:
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer
Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
White washing with lime to give an even shade :
Finishing walls with textured interiors and exteriors paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Applying priming coat : With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing and applying two coats of fire retardant paint on cleaned wood / ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant.
Providing and fixing GI plaster mesh of nominal thickness 0.35 to 0.40 mm with zinc coating of 120 gms per sq m of all as directed.
Audio & Video Equipments Supply, installation, testing & commissioning of Digital Flush Mountable conference system (Chairman Unit) with On/Off push button with chairman priority, LED Indicator for microphone, detachable 12.2''unidirectional gooseneck microphone having adjustable stem and ON/OFF button with colored status indicator ring,flush type loud speaker ,end caps and other.The Unit shall be flushed mounted on the table and shall have Microphone socket for pluggable Microphone, request switch, Low Level Loudspeaker. All the module shall be pluggable type, and connected to Digital Interface Unit.
Supply, installation, testing & commissioning of Digital Flush Mountable conference system (Delegate Unit) with On/Off push button, LED Indicator for microphone, detachable gooseneck microphone with length not more than 7” with array/lobar polar pattern, Frequency response : should fall in audible range 70 Hz – 16 KHz.
Supply, installation, testing & commissioning of Central Control Unit Frequency response with audible range 70 Hz- 16 KHz, Total Harmonic Distortion less than 0.1%, Should be ableto operate upto 250 conferencing inputs without any software or accessorie, Number of Interpretation Channels – Min 2. Scalable upto 32, Four different microphone operating modes should be supported: Automatic, First-In/First-On (FIFO), VOX (voice activated) & Manual, including power supply unit to feed the required power to microphones.
Supply, installation, testing & commissioning of Digital Sound Processor with 12 analog inputs and 8 analog outputs, 8 mic/line level outputs, System configuration and control via Ethernet, Gigabit Ethernet port, RS-232 serial port, Rack mountable (1RU).
Supply, installation, testing & commissioning of Two Way Ceiling Speakers with Woofer 5.25 inch, vented pole piece & cast aluminum basket. Tweeter 1.1 inch (28 mm) advanced synthetic polymer dome, ferrofluid cooling, Crossover Frequency 2 kHz, Impedance 8 Ohms nominal, Frequency Response 55 Hz to 20 kHz (±3 dB), Frequency Range 45 Hz to 20 kHz (-10 dB), Power Handling Minimum 125 Watts program, Sensitivity 88.5 dB @1W/1m.
Supply, installation, testing & commissioning of Dual Channel Amplifier Output Power 120 Watts at 8 Ohms; Minimum 210 Watts at 4 Ohms; 420 Watts at 8 Ohms bridged; 210 Watts at 70 Volts[1] Input Signal Type Balanced or unbalanced analog line-level, Output Signal Types 4/8 Ohm or 70 Volt, Damping Factor >100, Protection Over Current, Over/Under Voltage, Over Temperature, DC Offset, Frequency Response 20Hz to 20kHz ±0.5 dB at 4/8 Ohms; 80Hz to 20kHz +0/-3 dB at 70 Volts.
Supply, installation, testing & commissioning of Control Processor with 512MB RAM & 4GB Flash memory, Expandable storage up to 1TB , memory card slot, USB 2.0 host port, wired communications, computer & web based control, 1 x RS-232/422/485 COM port with hardware and software connectivity, 2 x RS-232 COM ports, 8 x IR/serial, eight relay & eight Versiport I/O ports, Full Unicode (multi-language) support.
Supply, installation, testing & commissioning of Touch Control tabletop panel of 10.1". capacitive widescreen active‑matrix color display, 1280 x 800 WXGA display resolution, Minimum 5 backlit soft‑touch buttons, PoE (Power over Ethernet) , built‑in light sensor builtin built‑in light sensor, comptiable with control processor.
Supply, installation, testing & commissioning of Presentation System with wired & wireless connectivity, HDMI Input HDCP 1.4, EDID; Supports management of HDCP & EDID, Ethernet 100 Mbps,HDMI, OS Support Apple® iOS®, Android™, Windows® 7, Windows 8, Windows 10, macOS®, Chrome OS™Output HDCP 1.4, EDID, CEC; Supports management of HDCP & EDID, Video Frame Rate Up to 30 fps, audio supported.
Supply, Installation, Testing & Commissioning of 65 inches Professional Display Operating system android 5.1 or better, Brightness minimum 400 cd/m2, Contrast 1200:1, Viewing Angle 178 x 178 degree, Size 57.5" (w) x 32.9" (H), Colours 1.07 Billion.
Supply, installation, testing & commissioning of Ceiling Mount Kit for the above display panel, Weight capacity upto 50 Kg, Material SS.
Supply, installation, testing & commissioning of Network Switch with 48 ports, Ports, L3 - managed, Interfaces. 48 x 10Base-T/100Base-TX - RJ-45 - PoE; 1 x console - 9 pin D-Sub (DB-9) - management; 4 x 10Base-T/100Base-TX/1000 Base-T - RJ-45; 2 x SFP (mini-GBIC), Flash Memory 16 MB.
Supply, installation, testing & commissioning of Shielded twisted pair cable, 23 AWG solid copper conductor, Polyethylene Insulation, 4 Pairs wrapped in polyester tape & aluminum foil with drain wireHigh Density Polyethylene Insulation, Cable Diameter : 7.5 mm, RJ 45 connector on both sides , Length 3 meters.
Supply, installation, testing & commissioning of Shielded twisted pair cable, 23 AWG solid copper conductor, Polyethylene Insulation, 4 Pairs wrapped in polyester tape & aluminum foil with drain wire High Density Polyethylene Insulation, Cable Diameter : 7.5 mm, RJ 45 connector on both sides, Length 20 meters.
Supply, installation, testing & commissioning of Speaker cable Stranded 2 x 2.5 sq mm, PVC insulated & soft PVC sheathed copper low loss, low conductance.
Supply, installation, testing & commissioning of Equipment Rack, Size 32 u, with front & Rear lockable door, Castors.
SUBHEAD - VI : FLOORING
Providing and fixing 18mm thick gang saw cut mirror polished premoulded and polished machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 Cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment. epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all level Granite of any colour and shade Area of slab over 0.50sqm
Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work / Marble Work
Extra for fixing marble / granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with expoxy resin based adhesive including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick
Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Udaipur green marble
Extra for pre finished nosing to treads of steps of marble stone.
Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 metre.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer?in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.Wall tile Size(300 x 450 mm)
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size
Size of Tile 600X600 mm.
Size of Tile 1000 x 1000 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Double charge vitrified tile polished finish of any size
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red
Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately).
Red sand stone - 30mm thick gang saw cut stone
White sand stone - 30mm thick gang saw cut stone
Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-in-charge.
Providing and fixing Glass Reinforced Concretepattern, design, thickness and color of M/S (G.R.C) Screens in approved size, UniStone make or equivalent. The Screens should be made from ‘53 grade’ White Portland Cement manufactured by ‘JK Cement’ or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by ‘Saint Gobain’ or equivalent, Super Plasticizers manufactured by ‘BASF’ or equivalent, Polymers manufactured by ‘BASF’ or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by ‘BAYFERROX (Germany)’ or equivalent. The material casting should take place in Synthetic Rubber / FRP Mould manufactured by ‘Reckli’ or equivalent. The fixing of Screens should be ‘Dry fixing’ i.e. to be done with Stainless Steel ‘L’ shaped Clamps, dash fasteners and pins.
Supply & fixing of non wooven washable wall paper with inlay work on finished surface i.e. on ceiling or wall as directed by Engineer-in-charge.
SUBHEAD -VII : DOOR WINDOW & WOOD WORK
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile C Fixing with adjustable lugs with split end tail to each jamb
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S including cost of adhesive of approved quality .1.0 mm thick
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete. 2nd class teak wood 50x12 mm
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing and fixing chromium plated brass 100 mm mortice latch and lock ISI marked with six levers and a pair of lever handles of approved quality with necessery screw etc.complete.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) a) For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.) Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge. Pre-laminated particle board with decorative lamination on both sides
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panels of 4.0 mm thickness.
a) 6mm toughened glass
b) 8mm toughened glass
c) 12mm toughened glass
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock and stopper all inclusive all complete as per direction of Engineer-incharge.
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
Providing and fixing aluminium tower bolts ISI marked anodised ( anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete:
Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Twin rubber stopper
Providing and fixing of rubber nylon door buffer (dia of 40mm and 50mm long) on wall with rowl plug and screw.
Providing and fixing the following hardware fittings of approved make :a)Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : i) Size 125 x 64 x 1.9 mm
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
Providing and fixing to existing door frames. 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge.
Design Manufacture supply election & commissiong of motorized RCC Door consisting of Heavy Duty Drive Wheel assembly-1set and non drive Wheel boggie-1Set high torque drive machanism (2mtrs/Min) BottamRailwith fixing accessories, Top guide & Roller , Control panel Limits Switch power Feeding arragement including RCC with reinforcement as per direction of engineer in charge.
Size-9.0L X 6.5H X 2.0W for 9/15Mev bay
Size-7.0L X 5.5H X 1.3W for 2/6Mev bay
Size-6.0L X 4.5H X 04W for 450KV
SUBHEAD -VIII : STEEL WORK
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
Providing and fixing bolts including nuts and washers complete.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing 5 mm thick M.S. sheet door (With Door limit switch) with built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel, all necessary fittings complete, as per engineer in charge .
Providing and fixing Lead Sheet 2mm Thick with , all necessary accessory complete not bolt etc., as per direction of engineer in charge .
Motorised rolling shutters:- Providing ,fitting,fixing of motorised rolling shutters made up of interlocked Galvalume manufactured in accordance with standards EN 13241-1:2003 +A1:2011.The shutter shall be designed as per clints specifications conforming to IS 6248: Specifications:Curtain profile is fabricated fire warrior curtain made up of 79mm cold rolled galvalume/ galvanised steel of 0.9mm thickness. Guide Rails: Depth: As per width of rolling shutter provided with special shaped 'Omega' guides with integrated rubber and brush seal ensuring quite shutter travel. Operation:Compact Gear operator with an IP40 Protection rating.
Drive Unit:It is made up of a worm gear with hollow shaft an integrated safety brake,integrated limit switches,an electric motor,an emergency manual operation in accordance with product standard EN1324-1 doors and EN12453 safety for power operated doors. Overload safety factor=4 x nominal motor amperage. Duty rating-According to shutter weight. Output speed-To allow the operating forces to comply with EN12453. Torque Enhancement:-Side one motor with mechanical limit switch.safety brake(RSB 10A,15A,20A,30A according to the tyoe of assembley.Special bracket for chain transmission sprockets,chain and screws. Control units for 3 phase motors-Cb-300
Motorised Rolling Shutters size 5mtr x 6.5 mtr
Motorised Rolling Shutters size 9mtr x 5.5 mtr
Motorised Rolling Shutters size 4mtr x 4.5 mtr
Motorised Rolling Shutters size 4mtr x 5 mtr
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- charge, (area of grill to be measured).
Extra for providing mechanical device chain and crank operation for operating rolling shutters. Exceeding 10.00 sqm and upto 16.80 sqm in the area
SUBHEAD - IX : ROOFING & WATER PROOFING
Providing and fixing on wall face unplasticised Rigid Single socketed PVC rain water pipes conforming to IS : 13592 Type A, along with injection moulded fittings as required e.g., bends on any angle, sockets, junction, cowls, offsets, access pieces, including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, providing and fixing MS stays & clamps and cutting & making good the holes in floors and walls wherever required etc. all complete. (For Rain water pipe).
a) 110 mm diameter
b) 160 mm diameter
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing
perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS:2645 and approved by Engineer - in- charge over the RCC slab including adjoining walls up to 300 mm height including cleaning the surface before treatment.
Laying cement concrete using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer - in- charge over 20mm thick layer of cement mortar of mix 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS2645 and approved by Engineer - in- charge to required slope and treating similarly the adjoining walls up to 300 mm height including rounding of junctions of walls and slabs. After two days of proper curing applying a second coat of cement slurry admixed with proprietary water proofing compound conforming to IS:2645 and approved by Engineer - in- charge .
Finishing the surface with 20 mm thick joint less cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS:2645 and approved by Engineer - in- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making of 300x300 mm square 3mm deep. The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge. a) With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Providing & fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm,at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction,including fixing perimeter channels 0.50mm thick 27mm high Contd:/
having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes,finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and suitable for boards, all as per manufacture’s specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specificaton and direction of the Engineer in charge but excluding the cost of painting with: 8 mm thick Calcium Silicate Board made with Calcareous &Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process.
Supplying and fixing of precoated Zincalume/Galvalume sheet roofing of 0.5mm TCT -AZ-150, 550 mpa (Alumunium Zinc Alloy couting of 150 gms, per sqm total on both sides) as per AS: 1397 in cover width of 1000-1020 mm, (size, shape and pitch of corrugation as approved by Engineer-in-charge).The end rib shall be designed for anti-capillary action, to avoid any seepage of water through the lateral overlap.The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness (BMT), Hi-strength steel with min. 550 MPa yield strength.The raw material shall be of Tata BlueScope ,Kirby .The steel sheet shall be fastened with 25 μm zinc-tin alloy coated, Hex head, self-drilling screw as per AS 3566-2002 Class 3 fasteners of approved make with EPDM washer as per the requirement considering the profile shape and design load.Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportaion and should be suppplied in single length upto 12meter or as directed by Engineer-in-charge.
SUBHEAD - X SANITARY INSTALLATIONS
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Supplying and fixing approved quality European water closet with FRP cistern set comprising of : ( a ) Star White glazed European water closet with wash down pattern of approved make with P or S trap fixed to floor with necessary teak wood plugs, CP brass screws, etc. ( b ) 10 ltrs. capacity PVC low level flushing cistern made of corrosive resistant materials fixed to wall with necessary brackets and screws, and plugs with matching chromium plated flush bend with float valve and flushing arrangements of slimline or equivalent. ( c ) 15 mm heavy quality flexible PVC inlet connection with brass hexagonal check nuts with washer at both ends. ( d ) Approved make plastic seat and cover to match the colour of water closet and CP hinges fixed to water closet. ( e ) 15 mm CP brass Angular stop cock fixed between GI outlet and PVC inlet.
Providing and fixing wash basin with CI brackets,32mm CP brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever required. W.B White vitreous china wash basin(round/oval under counter) size 580 mm x 430 mm with 15mm C.P. brass pillar tap & Bottle trap, 15mm PVC connection pipe with angle valve and CP waste).
Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar tap, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require with White vitreous china flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap, 15mm PVC connection pipe with angle valve , waste coupling & 2 CI brackets.
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with fittings, standard size C.P. brass flush pipe, CP Angle stop cock along with Urinal Spreader, 32mm dia waste fitting,waste pipe, including cutting and making good the walls and floors wherever required :
Providing and fixing 16mm thick stone slab with table rubbed, edges rounded and polished, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. in Granite Stone of approved shade
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required with Kitchen sink with drain board 510x1040 mm bowl depth 200 mm
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. With Flexible pipe 32 mm dia
Providing and fixing beveled edge mirror of superior glass of approved quality complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing soap dish of approved quality including fixing with C.P. brass screws etc. complete.
Providing and fixing C.P. Brass towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality colour and make. 600mm x 20mm size
Providing and fixing C.P. Brass towel ring 200 dia size complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality colour and make.
Providing and fixing C.P. brass toilet paper holder with concealed fitting arrangement of approved quality colour and make.
Providing and fixing Health faucet with concealed fitting arrangement of approved quality colour and make.
Providing and fixing approved type SS Double coat hooks with concealed type screws.
Providing and fixing 15 mm nominal bore C.P. brass short body two way bib cock 15 mm nominal bore
Providing and fixing C.P.brass long body bib cock of approved quality conforming to IS standard and Weighing not less than 690 gms. 15 mm nominal bore.
Providing & fixing in position CP Soap dispenser.
Providing and fixing CP brass grating with frame of approved design including setting in floor with cement motor to match with floor finish as per architect requirement. a) Size 100 mm X 100 mm
Providing,fitting and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore
SUBHEAD - XI - INTERNAL WATER SUPPLY
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing this includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge. Concealed work, including cutting chases and making good the walls etc.
a) 15 mm nominal dia Pipes
b) 20 mm nominal dia Pipes
c) 25 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
25 mm nominal outer dia Pipes
32mm nominal outer dia Pipes
Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 15 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc.
a) 20 mm dia
b) 25 mm dia
c) 32 mm dia
Providing and fixing unplasticised P.V.C connection pipe with PTMT Nuts coller and bush of approved quality and colour. With 15mm nominal bore with 45cm length
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
(a) 500 Ltrs
(b) 1000 Ltrs
Providing and fixing Storage type Water Cooler with inbuilt RO water purification system including necessary inlet/outlets, CP angle stop cock & making drain connection etc. complete including all required fittings as required. Purified water production capacity - 60 LPH, Storage capacity -60 LPH
SUBHEAD - XII - EXTERNAL WATER SUPPLY
Supply erection testing and commissioning in position the following heavy class G.I. pipes conforming to IS:1239 cut to required lengths including all necessary fittings (conforming to IS:1879) and specials such as bends, tees, unions, reducers, flanges & plugs etc. fixing at wall/ceiling level supported by clamps, hangers etc,cutting hole in wall/floor/slab and making good the same good with cement concrete 1:2:4 / fire sealant complete as required.
a) 32 mm dia
b) 40 mm dia
c) 50 mm dia
d) 65 mm dia
e) 80 mm dia
Supply, installation, testing and commissioning of tanker inlet connection complete with 80 mm dia GI inlet piping, hose inlet connection, M.S. cabinet enclosure (epoxy painted after fabrication), pad locking arrangement, inlet flexible hose complete with all necessary arrangement.
Supply, installation, testing and commissioning of CI Butter fly valve of class PN 1.0 suitable for fixing between two flanges, including bolts, nuts, rubber insertions complete and of following sizes etc complete.
a) 50 mm dia
b) 65 mm dia
c) 80 mm dia
Supply, installation, testing and commissioning of C.I. dual plate type check valve tested to a pressure of 15Kg/sqcm. Including rubber gasket, flanges, union, nuts, bolts, washers & painting complete as required.
a) 50 mm dia
b) 65 mm dia
c) 80 mm dia
Supplying, Installation, Testing and Commissioning of CI / DI body flanged (both ends) type serviceable suction / Y strainer with (stainless steel / brass mesh) conforming to relevant IS specifications amended upto date complete including providing and fixing nuts, bolts, washers, gaskets etc. complete as required. a) 80 mm dia
Supply, installation, testing and commissioning of in position Vane Type mechanical water flow meter for following pipe size a) 80 mm dia
Constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for fire hydrants, with C.I. surface box 350x350 mm top and 165 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand / M-Sand :10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design. With common burnt clay F.P.S. (non modular ) bricks of class designation 7.5.
SUBHEAD - XIII - SEWERAGE DISPOSAL INTERNAL AND EXTERNAL
Internal Drainage Providing, fixing and jointing UV stabilized SWR (Type - B) pipes conforming to IS:13592 including all fittings such as bends, clamps, tees, cowls, clean out plugs, offsets, Y-tees, tees, door fittings, clips, clamps, stays etc. conforming to IS-14735, including jointing with rubber gasket fixing in sunk areas, Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cutting, chases/ holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects.
a) 75 mm dia.
b) 110 mm dia.
Providing, fixing,and jointing UV stabilized SWR (Type - B) pipes conforming to IS:13592 including all fittings such as bends as required lengths including all necessary fittings (conforming to IS:1879) and specials such as bends, tees, reducers, flanges & plugs etc. fixing at floor level with cement concrete 1:2:4 complete as per direction engineer in charge. a) 160 mm dia.
Providing, fixing, jointing and testing in position the following uPVC pipes conforming to IS : 4985 of 6 kg/cm2 pressure rating including all fittings like T - bend , elbow , reducer, clamps etc .with solvent joint and cement concrete around the pipe complete and making good the same complete as required. for internal toilet a) 32 mm dia.
Providing and fixing in position uPVC SWR floor trap conforming to IS:13592 including providing necessary steel support and as per Specification. Making proper connection cutting chase / hole in floors / slabs and bringing the same in proper condition and shape after placing the trap in right position complete as required. The hopper and trap shall be set in cement concrete mix 1:2:4 complete as required. a) 110 mm inlet and 110 mm outlet
Providing and fixing CP brass grating with frame of approved design including setting in floor with cement motor to match with floor finish as per architect requirement. a) Size 100 mm X 100 mm
Providing and fixing floor drain of size -100 mm x 50 mm of approved quality .
Providing and fixing Heavy Class SS grating with Cockroach proof SS strainer of approved design including setting in floor with cement motor to match with floor finish as per architect requirement suitable for waster and FT. a) Size 100 mm X 100 mm
External Sewerage Excavating trenches of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,depth upto 1.5m including getting out the excavated soil,& then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming ,watering, etc and disposing of surplus excavated soil as directed, within lead of 50m. All kinds of soil
a) Pipes, cables etc not exceeding 80 mm dia
b) Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia.
Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m :
Ordinary rock :
a) Pipes, cables etc not exceeding 80 mm dia
b) Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia.
Hard rock (blasting prohibited)
b) Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia.
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand/ M-Sand ) including testing of joints etc. complete :
150 mm dia. R.C.C. pipe
250 mm dia. R.C.C. pipe
300 mm dia. R.C.C. pipe
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of RCC pipes including bed concrete as per standard design :
a) 150 mm dia
b) 250 mm Dia
c) 300 mm Dia
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand / M-Sand ) including testing of joints etc. complete
a) 100 mm diameter
b) 150 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipe including bed concrete as per standard design:
a) 100 mm diameter
b) 150 mm diameter
Providing and fixing square mouth SW gully trap class SP-1 complete with CI grating brick masonry chamber and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg. as per standard design. 150x100mm size P type with common burnt clay F.P.S. (non modular) bricks of class designation 7.5.
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregrate 40mm nominal size ) inside plastering 12 mm thick with cement mortar 1:3 (1 Cement : 3 coarse sand) finished with floating coat of neat cement & making channels in cement concrete 1:2:4 mix (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design: Inside size 90x80cm and 45cm deep including C.I. cover with frame (light duty) 455x610mm internal dimensions total weight of cover and frame to be not less than 38kg (weight of cover 23kg and weight of frame 15 kg) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.
Extra for depth for manholes Size 90x80 cm Withcommon burnt clay F.P.S. (non modular) bricks of class designation 7.5.
Construction of Septic tank in R.C.C. including excavation in all kind of soil, P.C.C. in 1:3:6 / 1:2:4 R.C.C. M25 work in foundation walls and slabs, Reinforcement steel grade Fe-500, PVC encapsulated orange colour footrest, pre-cast RCC manhole cover and frame of Heavy duty (HD 20) circular shape 560 mm internal diameter, sludge chambers etc. complete with waterproof plaster inside & outside. 25 Users.
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
SUBHEAD - XIV : Road and Hardstanding
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
Supplying and stacking at site. Moorum
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. Cement concrete manufactured in automatic batching plant (RMC plant) i/c transportation to site in transit mixer
Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.)
Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. Using grade 'A' sealing compound conforming to IS: 1834.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Painting road surface marking with adequate nos of coats to give uniform finish with ready mixed road marking paint conforming to IS : 164, on bituminous/RCC surface in white/yellow shade, including cleaning the surface of all dirt, scales, oil, grease and foreign material etc. complete. New work (Two or more coats)
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand / M-Sand ) including testing of joints etc. complete
450 mm dia RCC pipes.
600 mm dia RCC pipes.
900 mm dia RCC pipes.
Providing and laying Polythene sheet (125 micron thick) confirming to IS :2508 antifriction layer on the sub base course complete as per specifications.( Overlaps atjoints of pvc sheet should be 100 mm wide )
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm
Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 .cm length and drilling holes upto 10 mm dia. etc. complete.
Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete.
SUBHEAD - XV : Arboriculture, Landscaping work
Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water) Trees Plant
Supply and stacking of Bottle palm plant of ht. 210-240 cm bottom girth 30-35 cm well developed in big HDPE bags.
Supply and stacking of Plumeria alba plant of height 120-135 cm. with 2-3 branches in bags of size 30 cm as per direction of the officer-in-charge
Supply and stacking of Ficus religiosa (Peepal) plant of height 150-165 cm. in big poly bags of size 30 cm as per direction of the officer-in-charge.
Supply and stacking of Azadirachta indica ( Neem ) plant of height 120- 130cm in big polybag of size 25 cm as per direction of the officer-in-charge.
Supply and stacking of Delonix regia (Gulmohar) plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge
Supply and stacking of Magnolia grandiflora plant of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.v
Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) : a) Screened through sieve of I.S. designation 4.75 mm
Providing and applying anti termite treatment of infected trees i/c all branches/leaves by spraying chemical emulsion 0.5% (Chlorpyriphos 20% EC) concentration through power spray machine (@ 100 ml Chlorpyriphos per tree i/c cost of chemical) and as per direction of officer-in-charge.
Making tree guard 53 cm dia and 1.3 m high as per design from empty coal tar drums, supplied free by the department, including providing and fixing 2 nos M.S. sheet rings 50 x 0.5 mm fixed with rivets complete in all respects including painting inside and outside of tree guard with:
Complete maintenance of trees(out side of lawn area), jobs like making of basin at regular interval i/c watering,weeding,prunning & application of fertilizer etc, (excluding the cost of material which shall be supplied by the department) and as per direction of officer in charge. a)Trees for 250 no/(up to 4 & up to 3 year Slow & Fast growing group =11113.25/250=44.45 Cost for per tree per month.
Lawn Plantation Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 20 mm
Rough dressing the trenched ground including breaking clods.
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation.
Fine dressing of the ground.
Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge
Weeding out of lawn by removal of all weeds and other wild growth with roots by forking including disposal of garden rubbish with all loads and lifts complete if top dressing required paid separately (cost of manure, sludge or extra good earth to be paid for separately) as per direction and satisfaction of officer in charge a)Where weeds are up to 50%
Shrubs Plantation Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water)
Providing and applying anti termite treatment of infected trees i/c all branches/leaves by spraying chemical emulsion 0.5% (Chlorpyriphos 20% EC) concentration through power spray machine (@ 100 ml Chlorpyriphos per tree i/c cost of chemical) and as per direction of officer-in-charge.
Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) : a) Screened through sieve of I.S. designation 4.75 mm
Supply and stacking of plant Bauhinia tomentosa (yellow) of height 60-75 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge.
Supply and stacking of plant Ficus blackii (F.vivion) (bushy) of height 150- 165 cm. with 8-10 branches and healthy foliage in earthen pots of size 30 cm as per direction of the officer-in-charge.
Supply and stacking of plant Euphorbia pulcherrima (dark red double bracts) well branched of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge
Supply and stacking of plant Calliandra, emarginata of height 45-60 cm. in earthen pot of size 20 cm as per direction of the officer-in-charge
Complete maintenance of shrub(out side of lawn area), jobs like making of basin at regular interval i/c watering,weeding,prunning & application of fertilizer etc, (excluding the cost of material which shall be supplied by the department) and as per direction of officer in charge.
Hedge Plantation Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
Providing and applying anti termite treatment of infected trees i/c all branches/leaves by spraying chemical emulsion 0.5% (Chlorpyriphos 20% EC) concentration through power spray machine (@ 100 ml Chlorpyriphos per tree i/c cost of chemical) and as per direction of officer-in-charge.
Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) : a) Screened through sieve of I.S. designation 4.75 mm
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water)
Supply and stacking of plant Dombeya mastersii of height 60-75 cm. with 4-5 branches in bag of size 25 cm as per direction of the officer-in-charge.
Supply and stacking of plant Ficus panda of height 45-60 cm. with 6-7 branches and healthy foliage in p.bag of size 25 cm as per direction of the officer-in-charge.
Supply and stacking of plant Euphorbia pulcherrima (dark red double bracts) well branched of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge
Supply and stacking of plant Thuja compacta of height 75-90 cm., conical shaped, well formed with healthy foliage in earthen pots of size 30 cm as per direction of the officer-in-charge.
Cutting of designer hedge/edge removing of cut materials, cleaning, hoeing of hedge/edge bed watering manure and applying insecticides and fungicides etc.(excluding the cost of material which shall be supplied by the department) and as per direction of officer in charge
Complete maintenance of the entire garden features having as per yard stick in the garden area i.e. lawn trees, shrubs, hedge, flower beds, foliages, creepers etc. including hoeing,weeding pruning replacement of plants, gap filling, watering, mowing of lawn, grass cutting by lawn mover and brush cutter , removal of garden waste, applying insecticide, pesticide & fertilizers(whenever required) top dressing of lawn with good earth and menure and maintenance of other garden related works as directed by office-in-charge (Cost of Good Earth, Manure, Fertilizer, Insecticide , Pesticide , lawn mover and brush cutter with fuel will be provided by the Department & other T & P material/articles shall be provided by the contractor.) a) Prestigious works / H.M. house & officers entitled to free Per Sqm accommodation.(as per yard stick 1Mali =1.00Acre)
SUBHEAD - XVI : Furniture
Supply of Computer Table size 1200x600x750 mm made out of 19 mm thick commercial board with 1 mm thick laminate on sides & front. Top to have 25mm thick postformed board, having drawer, key board and provision of CPU trolley, all drawer ride on telescopic sliding channel and back covered with 6mm thick commercial ply all exposed edges covered with teak wood lipping or PVC lipping (as required) and finish with melamine polish etc., all complete.
Supply of Executive Table of size 2400 x 1050 x 750mm made out of 19mm thick commercial board with 3.5mm veneer of approved shade on top, sides and front, along with drawer. Table top edging will be 15x32mm thick with half round moulding. All exposed edges to have 4mm thick teak wood beading with 75x30mm teak wood foot rest with all necessary hardware, locking arrangement etc. All exposed surfaces shall have approved shade of melamine polish & inner surfaces finished with Spirit polish etc, all complete.
Supply of High back Executive revolving chair with head rest and arms with specificastion as under:- Arm Material-PU, Chair Height- (min)1100mm, Backrest Height -800mm, Backrest Width - 450mm, Seat Depth and Height -390mm & 400mm respectively, Paint Type Powder coating , Density of Polyurethane Foam used in Seat 65 kg/Cum. Thickness of Polyurethane Foam used in Seat -50mm, Material of Fabric of Seat Cover- Net, Material of Fabric of Back Cover- Net, Colour – as per approved by engineer-in Charge, etc. All complete.
Supply of Visitor chair with arms with specification as under :- Chair Overall height - 815mm, Seat height (Min) - 450mm, Seat Depth & width - 450 & 500mm respectively, Backrest height & width - 490 & 500mm respectively, Type of Seat & backrest - Padded with polyurethane foam, Material of fabric of seat & back cover is vacuum formed from ABS sheet & upholstered voila fabric made from 100% polyester, Density of polyurethane foam used in seat & backrest-45±2kg/Cum & colour - as per approved by engineer-in-charge, etc. All complete. make:
Supply of Wooden Work bench of size 2400 x 1200mm and height 900mm made out of 19mm thick commercial board with 1 mm thick decorative laminate having one drawer and one cupboard, Drawer ride on telescopic sliding channel, top to have 2 mm thick Alluminium sheet and antistatic matt & connected to antistatic discharge system,having 300(H) x 100(D) x 2000(L) Wooden Box for Provision of 2 Nos. 5/15Amp Switch and socket,Box made out of 19mm thick commercial board with 1mm thick laminate & all edge covered with teak wood lipping all inner surface finish with spirit polish and outer edges finish with melamine polish etc., all complete.
Supply of Wooden Work bench made out of 19mm thick commercial board with 1 mm thick decorative laminate having one drawer and one cupboard, Drawer ride on telescopic sliding channel, top to have 2 mm thick Alluminium sheet and antistatic matt & connected to antistatic discharge system,having 300(H) x 100(D) x 2000(L) Wooden Box for Provision of 2 Nos. 5/15Amp Switch and socket,Box made out of 19mm thick commercial board with 1mm thick laminate & all edge covered with teak wood lipping all inner surface finish with spirit polish and outer edges finish with melamine polish etc., all complete.
Supply of Wooden Work bench of size 2400 x 920mm and height 900mm made out of 19mm thick commercial board with 1 mm thick decorative laminate having one drawer and one cupboard, Drawer ride on telescopic sliding channel, top to have 2 mm thick Alluminium sheet and antistatic matt & connected to antistatic discharge system,having 300(H) x 100(D) x 2000(L) Wooden Box for Provision of 2 Nos. 5/15Amp Switch and socket,Box made out of 19mm thick commercial board with 1mm thick laminate & all edge covered with teak wood lipping all inner surface finish with spirit polish and outer edges finish with melamine polish etc., all complete.
Supply of standard steel almirah of large size 1980 x 486 x 916mm with 4nos. of adjustable shelf made out of M.S sheet conforming to CR-2 Grade. Sheet thickness of side, top, bottom & back of Almirah is 0.8mm minimum and sheet thickness of door 1mm. Three way bolting & locking arrangement with powder coating, having pedestal width 75mm & pedestal depth 120mm.Colour of paint as per approved by Engineer-In-Charge,etc. All complete.
Supply of Standard steel Almirah of Medium size 1266x750x430mm with 3 Nos of adjustable shelf.Made of M.S Sheet conforming to CR-2 Grade Sheet thickness of side, top, bottom & back of Almirah is 0.8mm minimum and sheet thickness of door 1mm. . Three way bolting & Locking arrangement with Powder coating. Colour of paint as per approved by Engineer-In-Charge. Etc. all complete.
Supply of Conference Table ('U' Shaped) to seat 16 persons made out of 19 mm thick commercial board with 3.5 mm teak veneer on top and top edging will be 35x75mm thick with half round moulding. 19 mm thick commercial board tapered foot rest, vertical member with 19mm thick commercial board. Back with 19mm thick commercial board including 3.5 mm thick teak veneer all exposed edges to have teak wood beading including melamine polishing etc., all complete.
Supply of Slotted angle rack of size 2000 x 900 x 400mm with rubber shoes, Powder coated Slotted Angle of size 40mm x 80mm having thickness 2mm.5 Nos. shelves with 2 Nos. adjustable shelves. Rack is made up of M.S sheet of 0.8mm thickness with powder coating. Colour of paint as per approved by Engineer-In-Charge etc. All complete.
Supply of Steel stool of size 375 x 375 x 435mm made out of all complete. As per direction of engineer in charge.
Supply of modular laboratory table W=300/450/600/750/900 mm, D = 530mm, H = 635/485 mm. Configurations: 2 Shutters 1 Drawer MOC: MSCRCA: IS – 513 (1994), Thickness: LH/RH side panels, shutter front, Bottom panel, Top front, Drawer separator, shelf, Alignment channel should be of 1.2mm thk. Removable Back panel, Shutter cover, Fr. Rack strip, Top cover panel should be of 0.8mmthk. Finish: Powder coating pure epoxy, thickness 40-50 microns. Handle: Anodized Aluminum Recessed-Type, CTC: 160.0mm. Lock: Units have a locking facility with 180°and 10 lever cam lock mechanism (except for sink and corner unit). Hinge: Knuckle-butt type SS Hinge. Screw: SS304. Shutter should be of twin-type construction with sound dampening effect using profeel. Shutter cover should be equipped with Bump on for sound dampening. Ball Slide: 500mm Length (required only for drawer unit). Shutter should have.
Supply of Dressing stool of size 375 x 375 x 435mm made out of 12mm thick commercial ply front with 1mm thick laminate. Top to have 12mm thick commercial ply with 50mm with density of foam 40kg/m3 minimum duly upholstered with approved fabric (cost of fabric not to exceed Rs.400/ metre). Provided with 4Nos castors finished with spirit polish etc. all complete.
SUBHEAD - XVII : Internal Electrification , Power Wiring, FLP Fixture & Cabling
LIGHT POINTS Point wiring for light points, fan points, exhaust fan points, 6A plug and socket with 2 runs of 1.5 Sq. mm FR PVC insulated, multistranded, copper wire of 1100V grade laid in and including 25 mm dia. heavy gauge FR PVC conduit in concealed in ceiling / walls conforming to IS 732 including one run of 1.5 sq.mm FR PVC insulated, multistranded, copper earth wire of 1100V grade including all accessories such as junction boxes, conduit bends, elbows and ceiling rose, anodised GI switch box with modular switch and the box covered with front plate. Cutting, chases in wall and making them good after fixing modular type switches as per requirement in sheet steel boxes of adequate sizes to accommodate switches, sockets, electronic fan regulator etc. (Including sub main wiring of 2 runs of 2.5 sq.mm & 1 x 1.5 sq.mm FR PVC insulated, multistranded, copper wire of 1100V grade in 25 mm dia heavy gauge PVC conduit with conduit accessories etc. complete).
a) One light point controlled by one 6A switch.
b) Two light point controlled by one 6A switch.
c) Three light points controlled by One 6A switch
d) One exhaust fan point controlled by one 6A switch
e) One Ceiling fan point controlled by one 6A switch including one 100W step type electronic regulator and MS fan hook box.
f) One 3 pin 6A plug socket controlled by one 6A switch (Dependant)
Supply and wiring for 6A Socket outlet with 2runs of 1.5sq.mm FR insulated multistranded copper conductor wire and 1run of 1.5 sq.mm earth wire laid in and including heavy gauge 25mm dia PVC conduit concealed in wall/ceiling along with required accessories, supply and fixing of 6A 3 pin modular type socket with switch in anodised GI box and front plate complete with fixing accessories including all accessories such as junction boxes, conduit bends, elbows and ceiling rose, anodised GI switch box with modular switch and the box covered with front plate. Cutting, chases in wall and making them good after fixing modular type switches as per requirement in sheet steel boxes of adequate sizes to accommodate switches, sockets, etc. as required. (Independent)
Supply and wiring for 6A Socket outlet with 2runs of 1.5sq.mm FR insulated multistranded copper conductor wire and 1run of 1.5 sq.mm earth wire laid in and including heavy gauge 25mm dia PVC conduit concealed in wall/ceiling along with required accessories, supply and fixing of 3 Nos 6A 3 pin modular type socket with 1 No 16A switch in anodised GI box and front plate complete with fixing accessories including all accessories such as junction boxes, conduit bends, elbows and ceiling rose, anodised GI switch box with modular switch and the box covered with front plate. Cutting, chases in wall and making them good after fixing modular type switches as per requirement in sheet steel boxes of adequate sizes to accommodate switches, sockets, etc. as required. (Independent)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But with MCB/RCCB/ Isolator) a) 8 way (4+24) double door (Horizontal type) with 1 No. 40A 4P RCCB as incomer and 24 Nos. 6-32A SP MCBs as outgoing.
Supply, installation, testing and commissioning of following light fittings complete with low loss electronic ballast, lamp holder, electrical connections by providing 3C x 1.5sqmm flexible wire, fixing & mounting accessories. All the fittings to be supplied with rated power lamps/CFL/LED etc., complete.
a) 2x19W LED Surface Type Light Fixture
b) 2'x2' LED Recessed Type Light Fixture
c) 2'x2' LED Surface Type Light Fixture
d) Surface & wall mounted batten with extruded aluminium housing LED Mirror Light Fixture
e) LED Ceiling Light Fixture
Supply and fixing of ceiling fan of 1200mm sweep ( white colour) suitable for operation on 230/240V, 50Hz, single phase, AC Supply complete with double ball bearing motor, required down rod, capacitor, three MS blades etc complete. (5 Star Rating)
Supply, Installation & testing of 400mm wall bracket fan suitable for use on single phase, 230 volt, 50Hz AC supply complete with all accessories as required
Supply, Installation & testing of following 900 RPM Exhaust fan suitable for single phase 230/240V, AC Supply complete with motor MS louvers , mounting brackets, all accessories etc complete as required.
a) 300mm dia
b) 380 mm dia
POWER WIRING Supply, installation, testing and commissioning of 6 / 16A, 5 pin shuttered type socket controlled by one 16A modular switch of combination type with indication lamp including wiring with 2runs of 2.5sq.mm FR insulated multistranded copper conductor wire and 1run of 2.5 sq.mm earth wire laid in and including heavy gauge 25mm dia PVC conduit concealed in wall / ceiling along with required accessories from DB to socket, including all accessories such as junction boxes, conduit bends, elbows and ceiling rose, anodised GI switch box with modular switch, socket and the box covered with front plate. Cutting, chases in wall and making them good after fixing modular type switches as per requirement in sheet steel boxes of adequate sizes to accommodate switches, sockets, etc. complete as required.
Supply, installation, testing and commissioning of factory made 20A, metal clad socket outlet controlled by 25A, 10kA, SP MCB, in and including MS painted box in concealed manner of adequate sizes including plug top with necessary accessories including wiring with 2runs of 4.0sq.mm FR insulated multistranded copper conductor wire and 1run of 2.5 sq.mm earth wire laid in and including heavy gauge 25mm dia PVC conduit concealed in wall / ceiling along with required accessories from DB to socket, including all accessories such as junction boxes, conduit bends, elbows and ceiling rose, anodised GI switch box with modular switch, socket and the box covered with front plate. Cutting, chases in wall and making them good after fixing modular type switches as per requirement in sheet steel boxes of adequate sizes to accommodate switches, sockets, etc. complete as required. etc. complete as required.
Supply, installation, testing and commissioning of factory made 32A, 3Phase+N+E, socket outlet controlled by 32A, 4P RCBO, 100mA in and including MS painted box in concealed manner of adequate sizes including plug top with necessary accessories including wiring with 4runs of 6.0sq.mm FR insulated multistranded copper conductor wire and 1run of 4.0 sq.mm earth wire laid in and including heavy gauge 25mm dia PVC conduit concealed in wall / ceiling along with required accessories from DB to socket, including all accessories such as junction boxes, conduit bends, elbows and ceiling rose, anodised GI switch box with modular switch, socket and the box covered with front plate. Cutting, chases in wall and making them good after fixing modular type switches as per requirement in sheet steel boxes of adequate sizes to accommodate switches, sockets, etc. complete as required. etc. complete as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
a) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
b) 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But with MCB/RCCB/ Isolator) a) 8 way (4+24) double door (Horizontal type) with 1 No. 63A 4P RCCB as incomer and 24 Nos. 6-32A SP MCBs as outgoing.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but with MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) a) 8 way (4 + 24), Double door with 1 No. 125A 4P, 25kA MCCB as incomer and 8 Nos. 32A TP MCBs as outgoing.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but with MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) a) 4 way (4 + 12), Double door with 1 No. 100A 4P, 25kA MCCB as incomer and 4 Nos. 40A TP MCBs as outgoing.(UPS)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But with MCB/RCCB/ Isolator) a) 4 way (4+12) double door (Horizontal type) with 1 No. 40A 4P RCCB as incomer and 12 Nos. 6-32A SP MCBs as outgoing.(UPS)
MV Cables Supply, laying,Testing and commissioning of following size 1.1KV grade XLPE insulated armoured aluminium / copper conductor under ground cable, in built up cable trench/ already laid RCC hume pipe or on cable tray with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid, providing protection with sand and bricks at sides and top and cable route markers at every 15mtr. interval and also at the turnings. The cable shall conform to IS 7098/ Part I. Armoring shall be IS 7098 Part IB
a) 3.5C X 185 Sq.mm aluminium
i) Suppy & laying in ground
ii) Suppy & laying in Tray/Trench/Hume pipe/GI Pipe
b) 3.5C X 50 Sq.mm aluminium
i) Suppy & laying in ground
ii) Suppy & laying in Tray/Trench/Hume pipe/GI Pipe
c) 4C X 16 Sq.mm copper
Suppy & laying in Tray/Trench/Hume pipe/GI Pipe
d) 4C X 10 Sq.mm copper
i) Suppy & laying in Tray/Trench/Hume pipe/GI Pipe
e) 4C X 6 Sq.mm copper
i) Suppy & laying in Tray/Trench/Hume pipe/GI Pipe
Provding end terminations for the cable specified below with Double compression type gland, Bi-Metalic lugs using crimping tool, Insulation tape, Identification tags etc. including end termination.
a) 3.5C X 185 Sq.mm aluminium
b) 3.5C X 50 Sq.mm aluminium
c) 4C X 16 Sq.mm copper
d) 4C X 10 Sq.mm copper
e) 4C X 6 Sq.mm copper
Supply and fixing of following size GI peroforated cable tray made out of 2mm thick MS sheet and the tray covered with 2mm thick MS cover including MS supports for fixing the tray, anchor fasteners and including 2runs of 25x6mm GI strip along with cable tray etc., complete as required.
a) 150mm x 50mm
b) 300mm x 50mm
Providing, laying and fixing following dia G.I. pipe (Heavy class) in ground complete with G.I. fittings including trenching (60 cm deep) and re-filling etc. as required
a) 50 mm dia
b) 80 mm dia
MV PANEL Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted MV panel made out of 2mm thick CRCA sheet for main frame and 1.6mm thick for partitions after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. The panel shall be got fabricated from manufacturers with CPRI Test certificate only.
OUTGOING 100 Amp, 25KA, 4P MCCB complete with operating handle - 2 Nos. 63 Amp, 25KA, 4P MCCB complete with operating handle - 14Nos. 32 Amp, 25KA, 4P MCCB complete with operating handle - 14Nos.
OUTGOING 125 Amp, 35KA, 4P MCCB complete with operating handle - 2 Nos. 63 Amp, 25KA, 4P MCCB complete with operating handle - 14Nos. 32 Amp, 25KA, 4P MCCB complete with operating handle - 4Nos.
Supply and laying of following size earth strips including excavation and refilling of earth when laid in ground and with all fixing accessories when laid in trench /cable tray with necessary interconnections with earth station and equipments. a) 8 SWG GI wire
FLP WIRING & FIXTURES Wiring for FLP Fixtures Supply and Wiring with the following size 1100V grade XLPE insulated Aluminium / Copper armoured conductor cables with FRLS outer sheath conforming to IS 7098 Part II on wall / ceiling / tray / pipe sleeves and excavated trenches including all accessories such as Flame proof junction boxes etc complete as required.
a) 4C x 2.5sq.mm armoured (Copper )
b) 4C x 4sq.mm armoured ( Copper )
c) 4C x 6sq.mm armoured ( Copper )
d) 4C x 10sq.mm armoured ( Copper )
e) 4C x 16sq.mm armoured ( Copper )
f) 3.5C x 35sq.mm armoured ( Aluminium)
Provding end terminations for the cable specified below with Double compression type gland, Bi-Metalic lugs using crimping tool, Insulation tape, Identification tags etc. including end termination.
a) 4C x 2.5sq.mm armoured (Copper )
b) 4 x 4sq.mm armoured ( Copper )
c) 4C x 6sq.mm armoured ( Copper )
d) 4C x 10sq.mm armoured ( Copper )
e) 4C x 16sq.mm armoured ( Copper )
f) 3.5C x 35sq.mm armoured ( Aluminium)
FLP Fixtures Supply ,Installation, testing and commissioning of following FLP/Well Glass fixtures made out of Cast Aluminium alloy, toughened clear glass cemented into a bazel ring which is bolted to the body, and lamp holder with Insulator mounted on a bush plate and secured with screws. The body shall be finished with epoxy Grey stove enamelled outside and White inside. The fixture shall be inclusive of all accessories including lamp & control gear box containing Choke, condencer & igniter suitable for Lamp
a) 80W LED Well Galss FLP fitting with LED, Cat. NO.WG/1234, certified by CMRI
b) 2x14W LED Tube Light with tube rod, Cat. No.FF/1272
c) Supply and Installation of 8mm dia. MS hook in the slab for mounting FLP Well glass fixtures.
Supply installation testing and commissioning of following rating FLP socket/ switch units in FLP enclosure installed on angle iron frame work with all fixing accessories such as Junction boxes etc complete as required.
a) 25A Single Phase 250V Grade FLP Socket with switch
b) 32A Three Phase 500V Grade FLP Socket with switch
c) 63A Three Phase 500V Grade FLP Socket with switch
Supply & installation of FLP Emergency stop botton
Supply & installation of FLP Eelectric Gong Bell
Supply & installation of FLP Eelectronic Hooter
Supply, Fixing, Testing & Commissioning of FLP LED Aviation Light including necessary hardware fabrication on 3mtr long 50mm dia class C GI pipe wih two coats of primer redoxide and two coats zinc chromate aluminium paint, required PCC foundation above ground level coping upto 300mm, terminal box with MCB, 2C x 1.5Sqmm unarmoured cable and end termination of same at both side by providing necessary gland lugs etc. complete.
Supply, Fixing, Testing & Commissioning of FLP limit switch with Top Push Roller with Cable Box etc. complete.
Supply, Fixing, Testing & Commissioning of FLP Long Lever limit switch including 1NO + 2NC with Cable Box etc. complete.
Supply, installation, testing & Commissioning of Flameproof Distribution board 6Way TPNMCBDB with 63A, 4Pole MCB as incomer and 18nos 6-32A SPMCBs as outgoings etc complete as required.
SUBHEAD - XVIII : LIGHTING PROTECTION, SPECIAL EARTHING
Supply and laying of following size earth strips including excavation and refilling of earth when laid in ground and with all fixing accessories when laid on the parapet with necessary interconnections with earth station and equipments.
a) 32 X 6mm GI Strip laid in Ground
b) 32 X 6mm GI strip conductor with DMC Insulated Supports
Supply and installation of vertical air termination with 40mm dia copper hollow sphere with spikes, fixed on 1000mm length 25mm dia Copper rod including PCC block and all fixing accessories.
Supply & Fixing of Weather proof test link box
Supply, installation, testing and commissioning of Static Discharge Meter fixed on wall with 25x3mm copper strip by brazing etc., complete
SPECIAL EARTHING Supply and laying of 25 X 3mm copper earth strips including excavation and refilling of earth when laid in ground and with all fixing accessories along with insulated supports when laid inside the building including all necessary inter connections.
Supply and laying of 25 X 3mm copper earth strips with Sleeve on DMC Insulators inside building with all fixing accessories
Supply and fixing of Static Discharge Handles made out of 32mm dia Copper rod fixed on wall with brass spacers and conected to 25x3mm copper strip by brazing.
Supply and fixing of Static Discharge Meter fixed on wall with 25x3mm copper strip
SUBHEAD - XIX : TELEPHONE & LAN WIRING
Supply and laying of 25mm dia. heavy gauge PVC conduit concealed in wall/ ceiling/floor by cutting chasing and making them good after laying of pipe and drawing of 12 SWG GI wire as fish wire for laying of LAN Cables at a later stage and supply of all fixing accessories such as junction boxes, conduit bends, etc., complete as required. (for Telephones) a) 25 mm
Supply & fixing of RJ - 11 modular type telephone sockets with shutter in a GI box with front plate and concealed in manner by cutting chasing in walls and making them good after fixing socket, etc., complete as required. a) Telephone socket outlet
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. a) 2 Pair
Supply and installation of following size Krone connectors in MS box complete as required. a) 10 Pair
SUBHEAD - XX : EXTERNAL ELECTRICAL SUPPLY & AREA LIGHTING
Supply and installation of double pole structure with 2 nos of 200 x 100mm ISMB poles of 11 metre long conforming to relevant IS specification with 13 Kg/mtr weight including MS base plate of size 300 x 300 x 6mm, earthing studs, including excavation in all kinds of soil, SDR and Hard rock providing 1:3:6 foundation PCC Pedestal and 1:2:4 coping complete with painting two coats of Red oxide primer and two coats of Aluminium paint the length above the ground and two coats of bitumen paint the length below the ground. consisting of 1set of 22KV AB Switch complete with all standard accessories, support insulators and provided with Lightning arrestors, necessary channels, accessories, Pin/Strain type insulators, Stay sets 2 Nos, DO Fuse and anti climbing device, danger notice board, ACSR jumpers, Alkathin pipe for connecting to euipment and all accessories like bolts, nuts etc. complete. all as per drawing.
Supply installation Testing and commissioning of 22KV 26.3 kA outdoor HT Vacuum Circuit Breaker Panels with Power Pack with 2V, 55 nos. maintenence free battery consisting of number of Breakers as given below and as per detailed specifications. The VCBs shall be with Motorised Spring Charging mechanism (110V AC from PT secondary). All VCBs shall have auxilary Relays and Annunciation as specified in Technical specifications. Suitable Power Pack shall be provided for 6 ON/OFF operations, the Closing & Tripping Coils shall be suitable for 24V DC Supply operation, Over current & earth Fault relays as specified in Specification. All VCBs shall have provision for Indications wired upto a terminal block 800A VCBs with Voltmeter with PT , Ammeter with CTs, Load Manager with RS 485 with Modbus connectivity, Over voltage & undervoltage relays with on delay timers ,Overcurrent & Earth Fault Numerical relay, Auxilary Relays for Bucholtz's Alarm & Trip and Oil/ Winding temperature alarm & Trip, Oil surge relay alarm, Phase Indication Lamps, Breaker On/Off/ Trip and Spring Charge, trip circuit healthy Indications include the same.-1 Nos a) Single Breaker panel
Supply, Installation, testing and commissioning of Harmatically sealed 630 kVA, 22000V / 433V, 3 phase, 50 Hz outdoor type double copper wound, delta/star connected (vector group-DYN 11), oil immersed, naturally oil cooled (ONAN), Distribution transformer on Load Tap Changer (± 15%) in step of 2.5% complete with RTCC panel & locking device. The transformer shall be suitable for operation at a temperature of 50 /55deg C and shall be supplied with suitable neutral ternimal on LT side and all accessories such as lifting lugs, H.T bushing on HT side and bus duct on LT sides, earthing terminals and rating plate. The transformer conformed to as per IS: 1180 Energy efficiency level 2 etc. complete as required.
Supply, laying, testing and commissioning of 3C X 185 sq. mm. aluminium conductor XLPE 22 KV (E) cable, direct in ground at a depth of 1000mm below ground level including excavation all kinds of soil, SDR & Hard Rock providing protection with sand cushioning, and bricks at sides and RCC slab on top etc and refilling the trench, removal of surplus earth, and cable route markers at every 15mtr. interval and also at the turnings etc. complete as required. The cable shall conform to IS : 7098/ Part II
Supply, laying, testing and commissioning of 3C X 185 sq. mm. aluminium conductor XLPE 22 KV (E) cable, in built up cable trench / already laid RCC Hume pipe or on cable tray with all installation materails. etc. complete as required. The cable shall conform to IS : 7098/ Part II
Supply and fixing of Indoor/Outdoor Heat shrinkable end terminations for the following size of aluminium conductor XLPE 22 KV (E) cable with all materials, Bi-metallic lugs using crimping tool, 22KV Insulation tape, Identification tags etc., including end termination and Earthing of Gland complete as required.
a) 3C X 185 sq. mm. (Indoor Type)
b) 3C X 185 sq. mm. (Outdoor Type)
Supply, fabrication and erection of 415V 1250A Rating TPN non phase segregated Bus Duct made out of 2mm thick CRCA sheet with painting after Seven tank process and consisting of TPN Aluminium Busbar (@0.8/sq.mm) mounted on DMC/SMC insulators including flexible Copper braided connections at the ends to facilitate connections and running 2 runs of 50x6 hot dip galvanized GI strip around the Bus Duct complete as required including necessary fixing arrangements etc complete. The Bus Duct shall be got manufactured only from Panel Builders with CPRI Test certificate after taking site measurements. After getting approval of the department.
MV PANEL Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire IP-54 Free Standing Floor mounted front operated MV panel made out of 2mm thick CRCA sheet for main frame and 1.6mm thick for partitions after seven tank process and painting with Epoxy powder coating over two coats of Red Oxide Colour of the panel should be Siemens gray (RAL 7032). The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. The panel shall be got fabricated from manufacturers with CPRI Test certificate only & should be ordered after approval of GA Drawing from the Department.
BUSBAR 1250Amp TPN Al Busbar BUS COUPLER 1250 Amp 415 volt, 50 kA 4P EDO ACB each complete with Microprocessor release having inbuilt overload, over voltage, under voltage protection with time delay, short circuit protection with time delay and instantaneous along with earth fault protection - 1 No. INTERLOCKING The Bus section and Incoming ACB's shall be E & M interlocked to achieve the sequence of operation, in case of manual override mode.
OUTGOING 1000 Amp 415 volt, 50 kA 4P EDO ACB each complete with Microprocessor release - 2Nos. 400 Amp, 50KA, 4P MCCB complete with operating handle - 5Nos. 250 Amp, 25KA, 4P MCCB complete with operating handle - 1Nos. 100 Amp, 25KA, 4P MCCB complete with operating handle - 3Nos. 63 Amp, 25KA, 4P MCCB complete with operating handle - 4Nos. 1 No-40 Amps TPN MCB - 10KA- with & 24 hrs Time switch with contactor & controlling of 4 nos 10 amps TPN MCB of 10KA
CONTROL CABLES (COPPER) Supply, laying, testing and commissioning of following size 1.1KV grade PVC insulated armoured copper conductor cable, in built up cable trench/ already laid RCC hume pipe or on cable tray with all installation materials. The cable shall conform to IS 7098
a) 24C X 2.5 Sq.mm cable
b) 12C X 2.5 Sq.mm cable
TERMINATION OF CONTROL CABLES (COPPER) Supply and fixing of cable end terminations with double compression cable glands of suitable size and Aluminium lugs with PVC Insulation tape, crimping tool etc complete as required.
a) 24C X 2.5 Sq.mm cable
b) 12C X 2.5 Sq.mm cable
Providing, laying and fixing 150 mm dia RCC pipe NP2 class in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) in all kinds of soil, SDR & Hard Rock and refilling of earth etc. as required.
Providing, laying and fixing 300 mm dia RCC pipe NP2 class in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (100 cm deep) in all kinds of soil, SDR & Hard Rock and refilling of earth etc. as required.
Supply and laying of 22KV grade Rubber Mats as per IS 15652 of size1000mm x 2000mm
Supply and fixing of 4 nos fire buckets including MS stand painted with red and duly filled with sand complete as required. conforming to IS:2546-1974.
Supplying and fixing of shock restoration chart written in English and Hindi duly Laminated etc complete.
Supplying of first aid box as approved complete with standard kit as prescribed by Indian Red Cross.
Supply and fixing of M.V. danger notice board in three language of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supply and fixing of H.T. danger notice board in three language of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supply of Hand Gloves -22KV grade
MV Cables Supply, laying and commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor under ground cable, in built up cable trench/ already laid RCC hume pipe or on cable tray with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid, providing protection with sand and bricks at sides and top and cable route markers at every 15mtr. interval and also at the turnings. The cable shall conform to IS 7098
a) 3.5C X 300 Sq.mm aluminium
i) Suppy & laying in ground
ii) Suppy & laying in Tray/Trench/Hume pipe/GI Pipe
Providing end terminations with Aluminium lugs, double compression type gland with neoprene gasket using Insulation tape, crimping tool etc complete as required. a) 3.5C X 300 Sq.mm
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Supply and laying of following size earth strips including excavation and refilling of earth when laid in ground and with all fixing accessories when laid on the parapet with necessary interconnections with earth station and equipments. a) 50 X 5mm GI Strip laid in Ground
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required. a) 300 mm dia
AREA LIGHTING Supply and erection of 36W LED street light fixture with authentically designed die cast aluminium housing pot optics reflector and toughned flat glass (IP 65). The contol gear box consist ballast, igniter, capacitor & lamp mounted on 50mm dia GI Pipe of 1.5 Mtr long with 2 nos CI clamps, nut bolts and screw for fixing on the wall including all prewired connection upto the terminal block and earthing connection all etc. Complete as required.
Supply, erection, Testing & Commissioning of garden light pole of 3.05M high (above ground), suitable for installation of post top lantern light fitting, designed galvanised pole shall be structurally sound, engineered to withstand adverse conditions, pole design parameters vary depending on the type of bracket and loading factor, all pole sections are welded using special v-groove technique by certified welders using high end MIG / TIG welding processes, built-in control box with service door including lock and safety chain consisting suitable connector for termination of aluminium cable upto 35 sq. mm (2 terminations: 1 Incoming and 1 Outgoing) including necessary fixing arrangement, the control gear tray is prewired with suitable rating of MCB, terminal connectors for loop-in loop-out arrangement, Finish : Coated with epoxy zinc phosphate primer and finished using environmentally stable polyurethane based paint, Installation :
Surface mounted with min. 6mm thick GI base plate and fitted on a pre-formed foundation, J type nut-bolts, 2nos. 50mm dia GI pipes of 1.5M long for incoming and outgoing of cables, including earthing arrangement, excavation & back filling bedding, PCC foundation 1:2:4, coping, PCC Pedestal. The wiring from junction box to light fixture shall be carried out with 3C x 2.5sg.mm multistranded copper flexible cable. The pole similar to (Make : K-LITE Cat No KP-6005 - (Ht. 3050mm & dia. 60mm)/ equivalent & the pole shall be fixed with 33W LED Post Top Light fitting integral type with control gear similar to equivalent and fixing accessories complete as required.
Providing Spiral coil earthing with 8 SWG GI wire including spreading of salt and charcoal as per IS 3043/87 with latest amendments.
SUBHEAD - XXI : FIRE ALARM WORK
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. a) 25 mm
Supply, Erection, Testing and Commissioning of Manual Call Point
Supply, Erection, Testing and Commissioning of Hooter
Supply, Erection, Testing and Commissioning of horizontal mounted Siren, 2.5 Km radius including Electrical connections etc., complete.
Supply, Erection, Testing and Commissioning of analogue addressable Fire Alarm control Panel (UL-FM approved).The fire alarm panel is designed to detect the fire through the fire detectors and process them into suitable audio – visual alarms, activate devices related to fire extinguishing systems, communicate to other Fire Alarm panels on peer to peer basis suitable for single mode optical fiber connectivity all necessary module/converter to be added for OFC connection.etc complete
Supply, installation, testing and commissioning of analogue addressable type multi sensor (smoke/Heat) photo electric detectors with LED indication lamp and all fixing accessories as per NFPA 721/ IS 11360.UL listed.
Supply, installation, Testing and commissioning of Response indicators with LED Indication lamps.
Supply, installation, testing and commissioning of analogue addressable type monitor Modules along with all fixing accessories.
Supply and laying of armoured FRLS Cables for detectors to FA Panel, Panel to hooters, manual call points, deluge valves, siren etc and of size 4C x 1.5 sqmm twisted pair shielded Copper armoured cable including termination, electrical connection etc complete.
Providing and fixing Carbon-di-oxide type fire extinguishers consisting of seamless M.S. cylindrical body, internal discharge tube, discharge nozzle, suspension bracket, conforming to IS:2878, finished externally with red enamel paint and fixed to wall with brackets complete with internal charges. a) Capacity 4.5kg
Providing and fixing Foam type fire extinguishers consisting of welded M.S. Cylindrical body, discharge nozzle, suspension bracket, conforming to IS:10204 finished externally with red enamel paint and fixed to wall brackets complete with internal charges a) Capacity 9 litres
Providing and fixing Foam type fire extinguishers consisting of welded M.S. Cylindrical body, discharge nozzle, suspension bracket, conforming to IS:10204 finished externally with red enamel paint and fixed to wall brackets complete with internal charges a) Capacity 5 Kg.
SUBHEAD - XXII : OFC Networking
Providing and Laying of HDPE- PLB Pipe 33mm ID, 40mm OD at Depth of 1 mtr. In all types of Soil including ordinary rock, SDR, HR, Refilling, Ramming etc Job Complete. a) One HDPE Duct in Trench
Supply and laying of 150mm dia NP2 class semi circular hume pipe for OFC protection
Provision of Massonry Chamber of size 900X900X500mm including excavation in all type of soils, ordinary rock, SDR, HR, brick masonry, RCC cover, finishing internal surface with cement plaster etc complete
Supply & fixing of RCC Cable route marker
Supply and Laying of Ployethelene Warning Tape of 0.5 mm thickness.
Supply & laying of Class C GI pipes of 65mm dia including necessary clamps specials & fittings etc all complete.
Supply & fixing of compression coupler
Supply & fixing of End cap/sealing cap
Supply & fixing of 1" Casing Caping / Flexible / PVC Pipe for CCTV / Access Control LAN Cabling
Supply & fixing 2" Casing Caping / Flexible / PVC Pipe for Telephone and LAN Cabling
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
Supply, fixing, termination & testing of Information Outlet Cat 6 UTP Single Port
Supply & fixing of Surface Mount Box
Supply and installation of opti point 410 entry (Mangan) with Lic.., open stage mains adaptor including power injectors
Supply & installation of 2 metre, Cat 6 UTP patch cord
Supply & installation of 1 metre, Cat 6 UTP patch cord
Supply & laying of 48 Core Fiber Optic Multitube Armoured Cable Single Mode ITU - G.652 D
Supply, splicing and testing of Pigtail SC SM Simplex Length- 1m
Straight Splicing of Fiber Cores in 24 / 12 Port LIU
Supply & installation of Adaptor SC SM -ZR-Sleeve
Supply & installation of Patch Cord LC-SC SM Duplex Length- 3m
Supply & installation of LIU 24 Port Rack mount with Blank SC Pannel
Supply & installation of LIU 24 Port Rack mount Blank
Supply & fixing 1x6 unloaded front adapter module SC Type for 24 Port LIU
Supply & splicing of 48 core Fiber Run Joint
Supply & installation of 15 U, 650 x 700 mm, Weather proof Indoor / Outdoor type Rack with inside Locked, Openable Plain side Pannels, MS door with earthing kit, A/C box 7 Soc. x 5A, and Accessories.
Supply, Installation, Testing and Commissioning of Power Injector for Open stage 15
Supply & installation of APC Smart-UPS RT, 700 Watts / 1000 VA,Input 230V / Output 230V, Interface Port DB-9, RS-232, SmartSlot, Extended runtime model, Rack Height 2 U with external Battery pack and RailKit ( Model : SURT1000UXI + UXPB48IN17 +SURTRK) or equivalent
Supply, installation, Testing and Commissioning of external batteries for 1KVA UPS, Battery type - Lead Acid, Nominal String Voltage - 36V DC Amp 65Ah 03Nos. For 2 hours of backup on full load with all accessories etc. complete
SUBHEAD - XXIII : DG Set:
DG Synchronizing Panel Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted MV panel made out of 2mm thick CRCA sheet for main frame and 1.6mm thick for partitions after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating 4P Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. The panel shall be got fabricated from manufacturers with CPRI Test certificate only. The PCC shall have atleast two spare cubicles to suit the highest rating outgoing MCCB. The size of all Panel Mounting Meters shall be 96X96mm. The Panels shall be mounted on U channels including supply and fixing of the same. Every ACB shall be
Incoming : 800A, 50KA 4pole MCCB with 400A 3pole AC3 Contactor link - 1sets 400A, 50KA 4pole MCCB with 400A 3pole AC3 Contactor link - 1sets Bus bars : 1250A 4P Aluminum busbars-1set Outgoings :1250A 50KA 4pole EDO ACB with micro processor based releases – 1set Metering for Each Incomer : Digital Voltmeter -1 set Digital Ammeter with resin cast CTs - 1set Digital KW Meter - 1set Digital Energy Meter -1set LED type phase indication lamps with individual fuse and toggle switch control -1set Indication Facia for DG Faults/ alarm with Hooter -1set
Supply & fixing of MS Exhaust Pipe of suitable dia cladded with 50mm thick Glasswool insulation covered with 24SWG Aluminium sheet. (20m in one Lot)
SUBHEAD - XXIV : CCTV System:
Supply INstallation testing and commissioning of 5 Mpx, Outdoor Bullet Camera ,1/2.8"" CMOS, lens 7-22 mm, Auto zoom and focus, H.265, H.264 compression,Smart Codec, internal/external 850nm Adaptive IR Range 60meter from same OEM, 120dB true WDR as per IEC 62676, Bi directional Full Duplex Audio, 1 Alarm In, 1 Alarm out, triple streaming,smart compression, Motion Detection, Camera Sabotage, Audio Detection, Object Counting, Adaptive Motion, Object Removal, and Directional Motion,IP66/67,NEMA 4X,IK10, IEC 60068:2-6 and 2-27.Camera shall support SD card 2TB, ONVIF profile S,G, & T,NDAA, UL and cUL Listed - UL 60950-1, UL/IEC/EN 60950-22, CE, FCC,EN 55032,EN 50130-4, EN 60950-1, operating Temp with IR +60deg. The Camera to be provided by OEM should not be complying to GB28181, GB/T28181-2011 standards and there should be no option to activate or deactivate GB/T 28181 standards in the camera web page/Settings."
Supply INstallation testing and commissioning of 1.2 EXPLOSION-PROTECTED FIXED COMPACT CAMERAS A. 5.0MPFixed CompactCamera with 4.9–8 mm lens. 1. Performance: Image Sensor: 1/1.8 inch progressive scan CMOS. Maximum Resolution: 1) Aspect Ratio: 16:9: 3200 x 1800. 2) Aspect Ratio: 3:2: 3072 x 2048. Imaging Rate: (50 Hz/60 Hz): 25 fps/30 fps. Dynamic Range: 3) WDR Off: 85dB. 4) WDR On: 120dB. Minimum Illumination: 5) Color: 0.055(F/1.8) lux. 6) Monochrome: 0.028(F/1.8) lux. Field of View: 7) Horizontal angle: 16:9: 50degrees to 91 degrees. 8) Horizontal angle: 3:2: 47 degrees to 72 degrees. 9) Vertical angle: 16:9: 29 degrees to 51 degrees. 10) Vertical angle: 3:2: 27 degrees to 48 degrees. A. System Certifications: 1. UL and cUL certification 2. CE certification
Supply of 5 Mpx, Outdoor Bullet Camera ,1/2.8"" CMOS, lens 7-22 mm, Auto zoom and focus, H.265, H.264 compression,Smart Codec, internal/external 850nm Adaptive IR Range 60meter from same OEM, 120dB true WDR as per IEC 62676, Bi directional Full Duplex Audio, 1 Alarm In, 1 Alarm out, triple streaming,smart compression, Motion Detection, Camera Sabotage, Audio Detection, Object Counting, Adaptive Motion, Object Removal, and Directional Motion,IP66/67,NEMA 4X,IK10, IEC 60068:2-6 and 2-27.Camera shall support SD card 2TB, ONVIF profile S,G, & T,NDAA, UL and cUL Listed - UL 60950-1, UL/IEC/EN 60950-22, CE, FCC,EN 55032,EN 50130-4, EN 60950-1, operating Temp with IR +60deg. The Camera to be provided by OEM should not be complying to GB28181, GB/T28181-2011 standards and there should be no option to activate or deactivate GB/T 28181 standards in the camera web page/Settings."
Supply of 1.2 EXPLOSION-PROTECTED FIXED COMPACT CAMERAS A. 6.0MPFixed CompactCamera with 4.9–8 mm lens. 1. Performance: Image Sensor: 1/1.8 inch progressive scan CMOS. Maximum Resolution: 1) Aspect Ratio: 16:9: 3200 x 1800. 2) Aspect Ratio: 3:2: 3072 x 2048. Imaging Rate: (50 Hz/60 Hz): 25 fps/30 fps. Dynamic Range: 3) WDR Off: 85dB. 4) WDR On: 120dB. Minimum Illumination: 5) Color: 0.055(F/1.8) lux. 6) Monochrome: 0.028(F/1.8) lux. Field of View: 7) Horizontal angle: 16:9: 50degrees to 91 degrees. 8) Horizontal angle: 3:2: 47 degrees to 72 degrees. 9) Vertical angle: 16:9: 29 degrees to 51 degrees. 10) Vertical angle: 3:2: 27 degrees to 48 degrees. A. System Certifications: 1. UL and cUL certification 2. CE certification
Supply INstallation testing and commissioning of 64 Chanel NVR - Supply installation Testing and Commissioing of Video Management Recording servers .it should supports upto 64 cameras for future upgradation .It should have Intel® Core i5- 9500 or better with 16 GB DDR4 ECC RAM or better. It should run on Windows® 10 IoT Enterprise 64-bit (LTSB) or latest.It should have M2. NVMe 256 GB for operating system.Shall support Dynamic Host Communication Protocol ( DHCP ) and Network Time Syncronisation Protocol ( NTP ) functionality. It shall have Mapping function. it should have in built plugins to integrate third party systems. Each Box should have Thoughput should be 200 Mbps. ,*Video Outputs- 4x Mini Display port 1.4 ,*VMS Should support ONVIF S,G & T ,Should have NVIDIA Quadro P620 (2 GB memory) ,Should have 1xGigabit Ethernet (1000Base-T) ports,1x 10 Gigabit Ethernet (10 G Base-T)
Supply , Installation,testing and commissioning of 24 port L3 Managed core Switch - 24 x 100/1G , 4 x 1G/10G SFP+ Ports , 4 x 10/25G SFP28 Ports with a slot for optional module, Redundant Hot Swappable Power Supply - AC/DC , Virtual stack Upto 8 Switch , 4GB or better, 16 GB Flash, SFP Should be from the same OEM . , 960Gbs or better , 540 Mpps or better , support for 64k Mac addess, 144k Ipv4 and 72 Ipv6 routes , Support for Egress rate limiting, Eight egress queues per port, IEEE 802.1Q, 802.3x, DiffServ, Jumbo frame Ipv4/ IPv6, MACSEC on 10G uplink ports , IGMP Snooping V1, V2, V3, MLD, PIM SM/PIMSSM/PIM-DM/PIM-Bidirectional, DVMRP, OSPF, RIP, BGP, IS-IS, ITU-T G.8032, IEEE 802.1s, IEEE 802.3ad/802.1AX Link Aggregation Control Protocol (LACP), Ipv4/Ipv6, DHCP Option 82, BPDU, STP Root
Guard, SIP detection, SPB or MPLS, IEEE 802.1ae, MIB, NTP, Macsec , SNMP V1,V2,V3, Web GUI, CLI, USB or equivalentmemory card, IP v6 management feature on openstandards, IEEE 802.1ag, TDM or equivalent standards , Should support Access Control Lists (ACLs), DHCP snooping, IEEE802.1x based port authentication, RADIUS/ TACACS+, SSL, SSH, port mirroring,NTP, IEEE 1588, AES, Syslog, MD5, LLDP-MED , IEEE802.1q, IEEE802.1d, IEEE802.1s, IEEE802.1w, ITU-T G.8032 ring resilience/ring protection, VRRP , Working memory/ Recovery memory , '0 to 45Deg ,CE, EN 55032, RoHS US UL 60950, CSA22.2 FIPS 140-2, EAL2 or equivalentEN 60825-1/2 Laser
Supply Installation Testing & Commissioning of Switch 24 Port POE Giga Port Switch - GigE fixed chassis 24 RJ-45 PoE 10/100/1G BaseT, 2 fixed RJ45/SFP combo (1G), 2 fixed SFP+ (1G) uplink or 10G stacking ports. 1RU size, internal 600W AC power supply. Includes United States power cord, guides, and 19" rack mount hardware. ALCATEL/ CISCO/BROCADE
Supply INstallation testing and commissioning of VMS - Software - Supply installation Testing and Commissioing of Video Management Softwarwe VMS should have smart motion Search for server side motion detection and quick retrieval of events *Edge Storage Auto Gap Fill functionality detects when a gap in local camera recording occurs, and automatically downloads video and audio (if present) to fill the gap *web based client allows viewing and exporting video without installing any software.*Imports users and roles from existing LDAP servers to reduce administrative overhead, and enables single sign-on (SSO) *Capable of listening for ASCII commands on a serial and Ethernet port simultaneously *Supports shared displays so operators can send video to surveillance personnel who need it most *Check on VMS and camera health using SNMP *Supports IPv4 and IPv6 cameras *Enables and supports Risk Management Framework (RMF) *TLS-based encryption over HTTPS *Extensible through mapping and plugins, including video information overlays and license plate recognition *should include feature, which is capable of polling for alarms from devices and performing specified actions when an alarm state change occurs *Incorporates FIPS 140-2 validated cryptographic modules. To ensure seamless deep integration VMS should be of same camera OEM
Supply, Installation, Testing & Commissioning of 6TB HD
Supply, Installation , testing and commissioning of 12 V SMPS DC Power Supply Unit, highly regulated and spikes free terminal voltage and heavy sourcing current for regulated terminal voltage
Supply, Installation , testing and commissioning of 55 inches UHD 3840 x 2160 (16:9) Direct-lit LED Display with brightness of 500 nits, viewing angle of 178° h/v. Display should be supplied with necessary mounting bracket as required
Supply, Installation, testing and commissioning of UTP 4 pair 23 AWG CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. 4 Pair CAT6 Unshielded, Twisted Pair (U/UTP) Cable 305 mtr per Box. Blue/Orange/White/Green in colour conforming to the following standards like ANSI EIA/TIA 568 C.2, EN50173, IEC 11801 3rd ED, frequency tested upto 700Mhz with Third Party Certificate etc. Cable Dia 6.1 ± 0.3, Cross-member (+) fluted Spine/isolator for uniform separation for all pairs.
Supply, Installation, testing and commissioning of Cat6 Tool less Information outlet for Data & Voice. Cat6 U/UTP RJ45 socket with built in crimping mechanism with capability of retermination without refreshing the wires. Toolless RJ45 Information outlet with insertion cycle (in & out) should be 2500 times (I/O) along with front side Label holder and transparent shutter. The Information Outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3bt standard for POE++ application
Supply , Installation , Testing and commissioning of CAT 6 jack panel
Supply, Installation, Testing and Commissioning of Workstation PC: Intel(R) Core(TM) i7-3770 Processor (8M Cache, up to 3.90 GHz); Memory: 4GB, NON-ECC, 1600MHZ; RAM: 4GB (1x4GB) Non-ECC DDR3 1600MHz SDRAM Memory; Keyboard: 12 function keys; Chassis: Tower/Workstation; DVD: 8X Slimline DVD+/-RW, Data Only; 20" TFT Monitor; Dual Graphics Card; Network interface card: Integrated Intel(R) 82579LM Gigabit1 Ethernet LAN 10/100/1000; Hard disk: 250GB, 7200 RPM 3.5" SATA 6Gb/s Hard Drive; Operating system: Windows 7 Professional 64 Bit.
Supply and laying of 25mm dia, 2.00mm thikness heavy duty FRLS PVC conduit concealed in wall / ceiling / floor including all accessories such as Junction boxes, conduit bends, etc. completed as required.
Supply, installation, testing and commisioning of 19" rack 32 U floor mount rack with all standard aceessories that include cable manager, fan, power bar with sockets etc. as per requirement
Supply, installation, testing and commisioning of 19" rack 9 U wall mount rack with all standard aceessories that include cable manager, fan, power bar with sockets etc. as per requirement
CAT6 UTP 24 AWG Patch Cord - 1 mtr with cross separator , Manufactured from stranded wires for longer flex-life , Minimum length of 1m, and maximum length of 5m Conforming to the following standards like EN 50173, ISO/IEC 60603-7 & 11801/IEC 60332-1, UL VW-1 with tensile strength >50N, number of insertion is 750
Supply, Installation, testing and commissioning of 24 port Cat 6 19" Modular Toolless Patch Panel (loaded) enable all possible combinations of the various types of cable (UTP, FTP, SFTP) mounted on the same panel by using various toolless connector blocks/modules. Have a metal structure enabling them to be durably fixed to the uprights of the 19” chassis and assuring automatic grounding between toolless RJ-45 connectors, the panel, and the 19” uprights of the enclosure. Include rear cable support with plastic cable guides to hold cable without need for cable ties. Include quick mounting system to mount the panel into the 19” rails without use of cage-nuts. These may be used to secure the connections of wifi access points, IP cameras, servers, or other critical devices. Front Removal IO's option for maintenance and trouble shooting with 6 Different Colours Labels for Labelling & Identification of Individual Ports. Tested and guaranteed under dual circuit IEEE PoE++ up to 90W for up to 2500 on-load connections / disconnections.
SUBHEAD - XXV : Solar Photo Voltaic Power Generation System:
Supply Installation Testing & Commissiong of Hybrid/Grid Interactive Roof Mounted Solar Photovoltaic(PV) system generation plant having PV Array Capacity of 15KW with battery backup using suitable rating polycrystalline Modules & accessories conforming to IEC61215 & IEC61730,& conforming to other standard as per technical specifications, with suitable mounting, fixing arrangement on the GI/steel structure.,asper below specification.
Polycrystaline Photovoltaic Module 335Wp with connecting cables and MC4 Connectors as per specifications
Solar Hybrid Grid Connected Inverter (3IN and 3OUT) 15KW 3-Phase (240V) , as per specifications
Battery Bank 240V 60Ah (20Nos.12V60Ah) Solar Tubular Battery for solar application with proper connections up to PCU as per specifications
Module Mounting Structure of Pre GI to withstand the wind velocity of 150KM/h with proper SS304 nuts and bolts.
Array Junction Box (IP65) alongwith DC Surge arrester, DC string fuse, Earthing Gland, as per specification.
Manual Onload Changeover Switch to by pass the Inverter-80A FP
Supply and Laying of DC-UV protected copper Cable, Single core for interconnetion of PV Modules with UV Protected Cable Tie a)1x4 sqmm Cu Cable (Red & Black)
Supply and Laying of-XLPE insulated PVC Sheathed Copper, cable in the existing surface/recessed conduit as required. (From AJB to PCU and PCU to Battery Bank) a)2x16 sqmm Cu Cable
Supply and Laying of XLPE insulated PVC Sheathed Al cable in the existing surface/recessed conduit as required. (From PCU to ACDB) a)4x10 sqmm Cu Cable
Supply and fixing 32mm CPVC Conduit with fitting for out door/roof top cabling as required.
Supply and fixing following sizes of FRP Prefabricated perforated Cable Tray with fitting for outdoor/rooftop cabling as required. 100Wx50Hx2mm, With fittings
Cement Concrete in foundation for module mounting structure, of (RCC1:2:4) & Installation and commissioning of above items/Equipments
SUBHEAD - XXVI : Two Way Communication System
Supply, Installation, testing and commissioning of central exchange software with license for 10 subscribers -Direct simplex and duplex communication with extended voice • Simplex and duplex multi-party call • scenarios, including conference calls; • Free numbering and 255 levels of priority; • Supports API for seamless integration with 3rd party applications and systems (e.g., DMR-API for integration with DMR Tier II digital mobile radio); • Voice recording with WEB access to stored audio; • Remote configuration and monitoring (WEB GUI); • Supported codecs: G.711A, G.711U, G.722.1(Siren7), G.722.1C (Siren14); • Interconnecting of two or more Armtel ICS Intercom Servers into a single communication system; • Integration with PBX through ISDN PRI or SIP
Supply, Installation, testing and commissioning of Server Hardware
Supply, Installation, testing and commissioning of Call station (SOS type) - Metallic housing made of aluminium; • IP66 protection rate; • VoIP intercom communication with real redundant dual Ethernet ports; • Customized set of modules; • Connection of subscribers via Ethernet or by ADSL communication line; • Optional in built 25W amplifier for direct connection to external loudspeaker for versions from RMLT.465311.015 to RMLT.465311.015- 02 and from RMLT.465311.015-21 to RMLT.465311.015-23 (Amplifier 25W retrofit kit CCS RMLT.465937.001); • Duplex and half-duplex communication via SIP protocol; • Dial pad for free dial of subscribers or version with direct keys;
• LCD alphanumeric display; • Volume control of integrated loudspeaker; • Front panel visual indication; • Built-in versions for flush mount installation. ArmtelICS communication system CCS-IP2 Compact IP Call Station RMLT.465311.015 SIP IP Armtel IP Protection against temporary immersion in water 14 ADSL ADSL connection IP 66 kHz Up to 14 kHz bandwidth from RMLT.465311.015 to RMLT.465311.015-02 from RMLT.465311.015-06 to RMLT.465311.015-20 from RMLT.465311.015-21 to RMLT.465311.015-23
Supply, Installation, testing and commissioning of Explosion proof call station - It is used in IP-network, built on standard equipment; • Different set of modules and optional equipment; • Individual simplex communication via SIP and Armtel-IP protocols; • Duplex (with handset) and half-duplex communication via SIP protocol; • Programming of direct keys / pushbuttons and free dial of subscribers; • Recording and playback of voice messages; • Control of analogue subsystems modules with “Relay” function; • Connection of subscribers via twisted pair through spare Ethernet port and by ADSL communication line; • VoIP communication with real redundant dual Ethernet ports; • Volume control of integrated loudspeaker and a handset speaker; • Indication of faults on call pushbuttons of associated device.
Supply, Installation, testing and commissioning of Desktop call station - IP desktop intercom station for use in control rooms or control centres; • Colour TFT display 4.3 inch; • 42 mechanical keys with multi-color status indications (e.g. call signaling); • Network connection via dual Ethernet interface (10/100 Base-TX) ; • Network connection via WiFi IEEE 802.11
Supply, Installation, testing and commissioning of Power supply with junction box 3amp 48 w
Supply, Installation, testing and commissioning of Cabinet (10U)
Supply, Installation, testing and commissioning of Switch 24 port POE
SUBHEAD - XXVII : EOT Crane
Design, Manufacturing, Supplying, Erection, Testing & commissioning of double girder, Crab type EOT crane (Flame proof) 20T Capacity, conforming to the standards given in IS: 3177, 807 & 2148 and other relevant IS standards of the latest revisions etc. all complete with all taxes, duties and other charges such as transportation to site, loading and unloading at stores / building, where to be installed etc., movement of material to work spot including the cost of paint as required. Duty: Indoor, Span: 25.7m, Bay length: 18.25m, Lift: 10m
Design, Manufacturing, Supplying, Erection, Testing & commissioning of double girder, Crab type EOT crane (Flame proof) 15T Capacity, conforming to the standards given in IS: 3177, 807 & 2148 and other relevant IS standards of the latest revisions etc. all complete with all taxes, duties and other charges such as transportation to site, loading and unloading at stores / building, where to be installed etc., movement of material to work spot including the cost of paint as required. Duty: Indoor, Span: 14.7m, Bay length: 12.7m, Lift: 7m
Design, Manufacturing, Supplying, Erection, Testing & commissioning of single girder, Crab type EOT crane (Flame proof) 5T Capacity, conforming to the standards given in IS: 3177, 807 & 2148 and other relevant IS standards of the latest revisions etc. all complete with all taxes, duties and other charges such as transportation to site, loading and unloading at stores / building, where to be installed etc., movement of material to work spot including the cost of paint as required. Duty: Indoor, Span: 9.8m, Bay length: 10.9m, Lift: 5m
Design, Manufacturing, Supplying, Erection, Testing & commissioning of Double girder, Crab type EOT crane 10T Capacity, conforming to the standards given in IS: 3177, 807 & 2148 and other relevant IS standards of the latest revisions etc. all complete with all taxes, duties and other charges such as transportation to site, loading and unloading at stores / building, where to be installed etc., movement of material to work spot including the cost of paint as required. Duty: Indoor, Span: 15m, Bay length: 21m, Lift: 5m
Supplying, Erection, Testing & Commissioning of for drag chain type of current collection system complete with drag chain with vertical separators, mounting brackets with tie wrap plates, support plates, trough with glide bar including mounting kit, along with cable from switch and with all necessary fixtures.
Supplying, Erection, Testing & Commissioning of Gantry Rails section 60/90Lb of prime material in length of 10m and above complete with mounting arrangement and fixing hardware etc., complete over the bay length to match the span of the crane within the permissible accuracy levels for span in height variation as per the QA plan.
SUBHEAD - XXVIII: Fire Fighting System
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 150 mm Dia
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :
a) 80 NB Class C
b) 100 NB Class C
c) 150 NB Class C
Supplying and fixing Single headed yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30Metre
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun metal
Supply, installation, testing and commissioning of weather proof lockable cabinet of made out of M.S. sheet having central opening and 4 mm thick glazed glass doors (Two nos.) suitably marked on the outside with the letters "FIRE HOSE" including necessary locking arrangement and shall be painted as per approved shade. The cabinet shall be suitable to accommodate 2 nos. 30 mtr long Hose pipe & 1 Nos branch pipe nozzle. Including mounting on wall with anchor fastener or on Angle frame where wall is not available. The sign, \" YARD HYDRANT\" BRIGADE INLET\" etc. shall be painted in \"CAPITAL LETTERS in white synthetic paint. Size - 1150 x 800 x 250 (For Yard Hydrant)
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 80 mm dia
Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 :
250 mm dia Ductile Iron Class K-9 pipes
150 mm dia Ductile Iron Class K-9 pipes
SUBHEAD - XXIX : Air Conditioning Work
Chiller Supply, installation, testing & commissioning of Air cooled Chiller with Semi - Hermetic Screw Compressors, suitable for operation on refrigerant R-134a. i) Screw type compressor with multi circuit, semi hermetic complete with automatic capacity control, safety switches, speed increasing gears, forced feed lubrication system etc. ii) 1 No.- Suitable capacity double squirrel cage induction motor with class 'B' insulation suitable for operation on 415+ 10% volts, 50Hz, A.C . Supply. ( for open type compressor motor H.P shall be at least 10% higher than the compressor BHP requirement at full load) iii) 1 No. Close transition type automatic star-delta starter suitable for each compressor motor complete with ammeter with CTs, over load protection, under voltage protection against phase reversal & independent single phase preventors etc complete as required. iv) Necessary drive arrangement v) 1 Set- Lubrication device consisting of automatic electric oil pump oil cooler, oil strainer, automatic pressure regulating valve oil heater, oil heater thermal switch etc. vi) 1 Lot- Refrigerant piping fitting, valves and accessories to inter connect compressor, condenser, chiller and expansion valve.
vii) Condenser with Cu-Al design having Epoxy Coating from factory for protection from harsh environment. viii) 1 Set - IP 54 Microprocessor based control panel complete with accessories as per specifications. ix) Lot- Refrigerant line accessories comprising of safety valves, angle valve liquid line indications, liquid level control etc. x) Lot- Water flow switches at inlet and outlet of chiller, water drain & air purge valves wherever required. xi) Lot- Suction line and chiller thermal insulation as required. xii) Lot-Frame work for mounting the condenser, chiller compressor and motor with base plate complete with antivibration pads/springs. xiii) Lot-refrigerant gas & compressor oil xiv) Lot-RCC foundation for the chilling unit. Suitable for ambient conditions of 35 C Chilled Water in 12.22 0C Chilled Water out 6.66 0C Actual chiller capacity shall be as under: a) 95 TR (2 W + 1 SB) Scroll Chiller-95TR (Actual at Ambient Temperature ) (2W+2S)
Hot Water Generator Supply, installation, testing and commissioning of electrically operated Hot Water Generator of efficiency more than 90% of capacity in multiple bank complete with PLC based microprocessor controls, electrical panels, stainless steel braided pipe flexible connector etc. confirming to tender specifications section. 80 KW , 60 C Outlet Temp (2W+1S) 80 KW , 60 C Outlet Temp
Chilled Water Primary Pumps Supply, Installation, Testing, Commissioning and handing over of Vertical inline split coupled Pump of capacity 228 USGPM at 30 Meters Head fitted with suitable Motor (TEFC and IP 55) chilled water including mechanical seal and coupling guard and necessary accessories etc complete. Suitable Nos & suitable capacity squirrel cage induction motor with IE2 class 'F' insulation suitable for operation on 415 volts +10% , 50 Hz, A.C. supply. max speed of pump shall be 3000 RPM. 2 working and 1 standby, Suction guide and Triple Duty valve shall be supplied along with the pumps Each pump shall have Variable Frequency Drive integrated to motor , with IP 55 protection and isolaton switch. The VFD shall comply with IEEE-519 and having built-in input chokes, for harmonic supression on current (THID) less than 30% to 35% only.The drive shall be having open protocole connectivity (Modbus / Bacnet / N2 / FLN). each (Head given is tentative,before procurement of pumps Actual head should be calculated as per site conditions and get it aprroved by the consultant)
Hot Water Pumps Supply, Installation, Testing, Commissioning and handing over of Vertical inline split coupled Pump of capacity 88 USGPM at 22 Meters Head fitted with suitable Motor (TEFC and IP 55) chilled water including mechanical seal and coupling guard and necessary accessories etc complete. Suitable Nos & suitable capacity squirrel cage induction motor with IE2 class 'F' insulation suitable for operation on 415 volts +10% , 50 Hz, A.C. supply. max speed of pump shall be 3000 RPM. 2 working and 1 standby, Suction guide and Triple Duty valve shall be supplied along with the pumps Each pump shall have Variable Frequency Drive integrated to motor , with IP 55 protection and isolaton switch. The VFD shall comply with IEEE-519 and having built-in input chokes, for harmonic supression on current (THID) less than 30% to 35% only.The drive shall be having open protocole connectivity (Modbus / Bacnet / N2 / FLN). each (Head given is tentative,before procurement of pumps Actual head should be calculated as per site conditions and get it aprroved by the consultant)
Floor Mounted / Ceiling Suspended Type Air Handling Units Supplying, installing, testing and commissioning of factory built Floor Mounted double skin type air handling units made of 43 mm thick panels consisting of pre plasticized G.I casing made of thickness 0.8 mm outside layer and G.I sheet of thickness 0.8 mm inside layer with polyurethane foam (PUF) insulation of density 40 kg/m3 factory injected between them by injection moulding machine, complete with Direct Driven Backward Curved Aerofoil Plug Type Fans with VFD's with aluminium finned copper tubes (tubes thickness not less than 0.5 mm),filter sections with 50 mm thick washable synthetic type pre filter having efficiency 90% down to 10 micron, chemical biological filter with dielectric media with an efficiency of MERV 16 and capacbility to gaseous contamination by 95% with a minimum IPD of 15mm along with plasmOX of 56 and 28 pins respectively for 2000 CFM (610x610) and 1000 CFM (610x305) respectively covering the entire surface area of the filter having EN, CE, RoHS, ISO certification along with FDA compliance. The filtration shall be certified by Indian Government Organization such as ICMR/ Central Government Institute/ SAIS/ IACS, alongduct mounted air purification system/ cell based Adavnced Oxidation plasma cell (AOP) based on nanoX technology certified by CCMB lab/ ICMR lab to kill covid-19 by greater than 99%
within 45 mins. The product shall have CE & RoHS Certiffication, Green Pro having the following wattage for 192 watts for 28000 CFM, 144 watts 21000, 117 watts for 15000 CFM and 96 watts for 10000 CFM for with complete electrical accessories etc., ,backward curved plug fan with aerofoil design blades with TEFC (IE-3) suitable for VFD operation at 415 ± 10% volts, 50 Hz, 3 phase, A.C supply, mixing box ,drain connections with drain valve, Flexible connection,stainless steel drain pan, necessary vibration isolation arrangement etc, suitable for VFD operation at 415 ± 10% volts, 50 Hz, 3 phase, A.C supply, mixing box . Humidifier Section with humidifier along with cellulose pad and recirulation pumps. TP isolator with MS enclosure box should be Provided. etc, complete as per specifications of following capacities
28000 CFM / 70 TR with 6 Rows Cooling Coil & 2 Row Heating Coil, 110 mm static pressure
21000 CFM / 52.5 TR with 6 Rows Cooling Coil & 2 Row Heating Coil, 110 mm static pressure
15000 CFM / 37.5 TR with 6 Rows Cooling Coil & 2 Row Heating Coil, 110 mm static pressure
10000 CFM / 25 TR with 6 Rows Cooling Coil & 2 Row Heating Coil, 110 mm static pressure
Ceiling Suspended Type Air Handling Units Supplying, installing, testing and commissioning of factory built Ceiling Suspended double skin type air handling units made of 43 mm thick panels consisting of pre plasticized G.I casing made of thickness 0.8 mm outside layer and G.I sheet of thickness 0.8 mm inside layer with polyurethane foam (PUF) insulation of density 40 kg/m3 factory injected between them by injection moulding machine, complete with Direct Driven Backward Curved Aerofoil Plug Type Fans with VFD's with aluminium finned copper tubes (tubes thickness not less than 0.5 mm), filter sections with 50 mm thick washable synthetic type pre filter having efficiency 90% down to 10 micron, chemical biological filter with dielectric media with an efficiency of MERV 16 and capacbility to gaseous contamination by 95% with a minimum IPD of 15mm along with plasmOX of 56 and 28 pins respectively for 2000 CFM (610x610) and 1000 CFM (610x305) respectively covering the entire surface area of the filter having EN, CE, RoHS, ISO certification along with FDA compliance. The filtration shall be certified by Indian Government Organization such as ICMR/ Central Government Institute/ SAIS/ IACS, alongduct mounted air purification system/ cell based Adavnced Oxidation
plasma cell (AOP) based on nanoX technology certified by CCMB lab/ ICMR lab to kill covid-19 by greater than 99% within 45 mins. The product shall have CE & RoHS Certiffication, Green Pro having the following wattage for 36 watts 4000 CFM with complete electrical accessories etc., ,backward curved plug fan with aerofoil design blades with TEFC (IE-3) suitable for VFD operation at 415 ± 10% volts, 50 Hz, 3 phase, A.C supply, mixing box ,drain connections with drain valve, Flexible connection,stainless steel drain pan, necessary vibration isolation arrangement etc, suitable for VFD operation at 415 ± 10% volts, 50 Hz, 3 phase, A.C supply, mixing box . Humidifier Section with humidifier along with cellulose pad and recirulation pumps. TP isolator with MS enclosure box should be Provided. etc, complete as per specifications of following capacities
4000 CFM / 10 TR with 4 Rows Cooling Coil & 2 Row Heating Coil, 75 mm static pressure
1800 CFM / 4.5 TR with 4 Rows Cooling Coil & 2 Row Heating Coil, 75 mm static pressure
1400 CFM / 3.5 TR with 4 Rows Cooling Coil & 2 Row Heating Coil, 75 mm static pressure
Ventilation Inline Fans Supplying, Installing, Testing and Commissioning of Inline fans complete with motor, supporting frame, gravity louvres,etc. as per drawings and specifications.
300 CFM ,. @ 15mm Static.
550 CFM ,. @ 15mm Static.
650 CFM ,. @ 15mm Static.
AHU's Controls/Three Way Modulating Valve Supply, Installation , Testing & Commissioning of Three way Modulating type Flow Control Valves of PN 16/25
Water flow rate 120.2-252 USGPM
Water flow rate 62.64-120USGPM
Water flow rate 41-62.4 USGPM
Water flow rate 21.84-40.8 USGPM
Water flow rate 7.4-14.4 USGPM
Water flow rate 3.8-7.2 USGPM
Water flow rate 2.4-3.6 USGPM
Modulating Thermostats. Heating and cooling
Plumbing (Insulated Chilled / Hot Water) Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled/hot water piping inside the building (with necessary clamps, vibration isolators, and fittings but excluding valves, strainers, gauges etc.) . as per specifications and as required. PIPING INSULATION: Chilled water shall be insulated with rigid Glass wool preformed pipe section. The insulation material shall be confirmed these specifications. The Fiberglass wool insulating material shall be applied for Chilled Water pipes as under. Rigid pre-formed molded sections of fiberglass wool having a uniform density of 80 Kg/m3.
Supplying, fixing, testing and commissioning of following PN-16 Rating valves, strainers, gauges in the chilled water plumbing duly insulated to the same specification as the connected piping and adequetly supported as per specifications. Butterfly Valves :
Butterfly Valves
Balancing Valves Providing and fixing the following motorized butterfly valves for chilled as per specifications
Y - Strainers
Pressure Gauges Providing and fixing pressure gauge with gauge cock, thermowell. complete as per specifications and drawings.
Thermometers with thermowell Providing and fixing thermometer Mercury filled V form type complete as per speci-fications and drawings.
Flow Switches Providing and fixing water flow switch on chilled water outlet complete as per specifications and drawings.
Automatic Air Vents Providing and fixing auto airvent purging valve complete as per specification and drawings.
Expansion tank Supplying, installation, testing and commissioning of PVC Tank with vent and draing connections with float valve, quick fill,overflow, and control valve etc as required.Tank should be closed from top with the removable type man hole cover plate with handle for cleaning purpose.All pipe points should have ball valves fitted on tank.Non return valve to be fitted at the tank outlet along with ball valve.
1000 LTRS Chilled water
500 LTRS Hot water
Drain Piping Supply,installation,testing and commissioning of rigid PVC piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber class ‘O’ .
Ducting Supply, fabrication, installation, balancing and commissioning of factory fabricated GI sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings of following gauges as per SMACNA standard:-
Thickness 24 G sheet
Thickness 22 G sheet
Thickness 20 Gsheet
Thickness 18 Gsheet
Grilles/Diffusers Supply,installation, testing and commissioning supply and return air grilles/ diffusers as per specifications and drawings including fixing frame of G.I./wooden in false ceiling/walls.
Aluminium supply air grill with VCD
Aluminium return/exhaust air grill without VCD
Aluminium Supply air Diffuser with VCD
Aluminium return/exhaust air Diffuser without VCD
Aluminium exhaust/fresh air louvers
Supply and installation of Thermal insulation material for Non-Exposed to weather Ducts with Closed Cell Class O Nitrile Rubber Elastomeric Insulation of Density 40 - 55 Kg/m3, Thermal Conductivity of 0.038 W/mk at 300Celcius Mean Temp. and µ≥7000 (without any additional vapour barrier) and with factory laminated chemically treated glass cloth of suitable color (Green for Supply Ducts and Red for Return Ducts) of 7mill / 0.18mm thickness tested for UV resistance as per EN ISO 4892-2 Method A; to be applied on Ducts using manufacturer's recommended Rubber based Adhesive, as per the approved specifications. The joints are to be sealed with 3mm thick nitrile rubber tapes pre-laminated with chemically treated glass cloth of matching color of duct insulation. The ducts are to be supported with duct supports made from PET foam as load taking member embedded in nitrile rubber foam sheet with outer metal face made of aluminium.
19 MM thick (Non Exposed) Supply Air Ducts
25 MM thick (Exposed) Supply Air Ducts
Duct Acoustic Lining Supply and fixing of acoustic lining of supply air duct and plenum with 15 mm thick Engineered Nitrile Rubber open cell foam having a Noise Reduction Coefficient of 0.55 with Density 140 - 180 Kg/m3 passing Class 1 Fire Performance test as per BS 476 Part 7, Air Erosion test for 10,000 fpm air velocity as per ASTM C 1071-05 and with built-in antimicrobial protection. The material should pass Fungi Resistance Test as per DIN EN ISO 846 Method A and Bacterial Resistance Test as per DIN EN ISO 846 Method C; to be applied using manufacturer's recommended Rubber based Adhesive in a blend of solvents.
Split HI-Wall Type Supplying, fixing, testing and commissioning of Hi Wall type split air-conditioning unit suitable to operate from 230±10% volt, 50 Hz, 1 phase power supply, with air-cooled evaporator with coil, fan, and fan motor, air-cooled condenser with hermetically sealed rotery / reciprocating compressor condenser coil, propeller fans controls, control panel, Including control wiring, necessary power cable, M.S. frame duly painted to locate Outdoor Unit etc. The Unit should be atleast 3 Star rated.
TOWER AC Supplying, fixing, testing and commissioning of Tower type DX air-conditioning unit suitable to operate from 230±10% volt, 50 Hz, 1 phase power supply, with air-cooled evaporator with coil, fan, and fan motor, air-cooled condenser with hermetically sealed rotery / reciprocating compressor condenser coil, propeller fans controls, control panel, Including control wiring, necessary power cable, M.S. frame duly painted to locate Outdoor Unit etc. The Unit should be atleast 3 Star rated. 3.0 TR
Refrigerant Piping Supply,installation,testing and commissioning of Interconnecting non exposed refrigerant pipe work with (19mm/13 mm thick) , Class 'O', k value-0.035 w/mk minimum, Density not less than 55 Kg/cu.m closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger & clamps
15.9 mm O.D. (insulation : 13 mm)
12.7 mm O.D. (insulation : 13 mm)
9.5 mm O.D. (insulation : 13 mm)
6.5 mm O.D. (insulation : 13 mm)
AC PANEL-for chiller Electrical Control Panel: Supplying, assembling, erecting, connecting, testing and commissioning Outdoor type of dust, damp and vermin proof free floor standing factory built sheet steel enclosed non-drawout modular type Panel fabricated out of suitable sized angle iron and flats, base channel and covered with 2.0mm thick PCRC sheet, duly painted complete with earth bus, aluminium bus bar, numbering & sign writing, interconnection & including the cost of connection through bus bar / copper conductor flexible connection with all accessories, rotary handles,phase barriers etc. complete as shown in drawing & as per specifications and mounted with the followings etc. complete as required. (All the starters should have NO/ NC contacts for remote/ fire control facility etc. complete) Incoming:
1 Nos 1000 A, 415V, 50 KA 4P ACB, electrical draw out type, Micro-processor based release (for over current and Earth fault protections) metering, protections, push buttons etc. complete in all respects as mentioned in specifications and as required with following accessories: Digital flush type class- I accuracy with power load manager, showing V, A, KVA, KWH etc. with 3 Nos. current transformers of 1250/5A ratio, 10 VA Class 1.0 metering. 1 Set of RYB phase indicating & ON/OFF/TRIP LED lamps with 2Amps. SP MCB's backup .Bus Bars:Electrolytic high conductivity aluminium three phase and neutral busbars rated at 415V, 50 Hz., 1250 amps. insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. Outgoing:- All outgoing feeders shall be provided with On indicating lamp with 2 A SP MCB protection & resin cast CT's class-1 suitable rating with digital Amps. meter.
350 A TPN MCCB '35 ka' with TM release etc. with MFM showing V,A, KWH, KVA & ON/OFF/Trip indications, complete - 3 set (for chillers) 200 A TPN MCCB '25 ka' with TM release etc. complete - 3 set (HWG) 100 A TPN MCCB '25 ka' with TM release etc. complete - 4 set (AHU) with suitable By-Pass VFD starter Panel 63 A TPN MCCB '25 ka' with TM release etc. complete - 1 set (CSAHU) with suitable By-Pass VFD starter Panel 40 A TPN MCCB '25 ka' with TM release etc. complete - 3 set (CSAHU)with suitable By-Pass VFD starter Panel 63 A TPN MCCB '25 ka' with TM release etc. complete - 3 set (Chilled Water pumps) with suitable By-Pass VFD starter Panel 63 A TPN MCCB '25 ka' with TM release etc. complete - 3 set (Hot Water pumps) with suitable By-Pass VFD starter Panel
Electrical cable: Supply of PVC insulated armoured aluminium conductor cables of 1.1 Kv grade 3 1/2 Core - 185 mm2
Electrical cable: Supply of PVC insulated armoured Copper conductor cables of 1.1 Kv grade
4 core - 16 mm2
4 core - 10 mm2
4 core - 6 mm2
Laying of PVC armoured Copper conductor cables in existing cable trays from main panel boards to various equipments through walls/ceiling with appropriate clamps and fixing arrangements, termination etc. as per specifications and drawings.
4 core - 16 mm2
4 core - 10 mm2
4 core - 6 mm2
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Upto 35 sq. mm (clamped with 1mm thick saddle)
Termination: Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2 Core - 185 mm2
Termination: Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 core - 16 mm2
4 core - 10 mm2
4 core - 6 mm2
BUILDING MANAGEMENT SYSTEM Supply, installation, testing and commissioning of Intel Core i7-4150 Processor (Dual Core, 3MB, 3.50GHz w/HD4400 Graphics) (338-BEED), 8GB Dual Channel DDR3L 1600MHz (4GBx2) (370-AAPE), Intel Integrated Graphics, 128GB Solid Drive (400-ADLX), Windows 7 Professional, English, 64bit, US English (QWERTY) Dell KB212-B QuietKey USB Keyboard Black (580-AAQX), Up to 90% efficient PSU Base 49.5cm (19.5 INCH) Non-touch with Camera, Integrated (321-BBGU), 8x Slimline DVD+/-RW Drive (429-AAMY), Dell USB Optical Mouse MS111 (570-AACR), ENERGY STAR Version 6.0 (387-BBEZ), System Power Cord (Philipine/TH/US) (450-AAOJ), Safety/Environment and Regulatory Guide (English/French/Dutch) (340-AGIK), 1-Watt BIOS (340-ABMZ), Heat Sink for Integrated Graphics (412-AADE), AIO Stand OptiPlex 3030 (575-BBCG), 19" TFT monitor
Supply, installation, testing and commissioning A4 Size Color Inkjet Printer with all complete.
SOFTWARE Supplying, Testing and Commissioning of the Graphical Software providing the facility to create / provide the following, static and animate the Graphics, Navigation between pages, display of logs, changing the time zones.The BMS platform shall natively support standard communication protocols such as Lontalk® and BACnet™. The software should be Web Based Software Required to remotely monitor the system for 5 concurrent users. Supplying, Testing and Commissioning of the necessary Hardwares/Softwares for Integrating it with 3rd party Devices on Bacnet/Modbus.
Supplying, Testing and Commissioning of the necessary Hardwares/Softwares for Integrating it with 3rd party Devices on Bacnet/Modbus. a) Chiller Integration on BACnet/IP- 3 Nos.(20 Points per pump) b)Electrical Syncronization Panel - 1 Nos c)DG Integation BACnet/MODbus - 2 Nos d)Fire Alarm on BACnet/MODbus - 1 Lot e) Primary Pump VFD Integration on BACnet/IP- 3 Nos.(9 Points per pump)
DDC Controller-Supply, Installation, Testing & Commissioning of Standalone Intelligent Microprocessor based Programmable DDC with inbuilt HMI, Onboard Modbus port, with Process bus for network functionalities based on KNX Protocol. It should have SD card interface for application and operating system upgrade & operating temperature range should be -20 to 60 degree.Celsius. It should include suitable Enclosures with all accessories including necessary switchgear, step down transformer, internal power and control cabling (excluding power & control cable to Fan), complete in all respect & as required to suit the site conditions etc.
Field devices-Supply, Installation, Testing & Commissioning of Air Differential Pressure Switch.
Field devices-Supply, Installation, Testing & Commissioning of Duct Temperature & RH Sensor.
Supply, Installation, Testing & Commissioning of Temperature and RH setpoint adjustor Device
Supplying & laying of signal cables. (2 core x 1.5 Sq.mm), PVC insulated, Shielded tinned copper conductor cable.
Supply & Laying of MS Conduit 25 mm for Signal & Communication Cable
Supply & Laying of GI Flexible Pipe
QUICK BUILDERS
RMS CONSTRUCTION PVT. LTD.
VISHAL BUILDERS
RIC Projects Pvt. Ltd.
SHRI GURMUKHDAS CONTRACTORS PVT. LTD.
Surendra Infrastructure Pvt. Ltd.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid