AGE Indpt Pachmarhi
AGE Indpt Pachmarhi Dist- Hoshangabad (MP)-461881
SPL REPAIR / REPLACEMENT OF BER E/M PLANTS AT AEC TRG COLLEGE AND CENTRE PACHMARHI.
2022_MES_572257_1
CA No. AGE(I)/PACH/of 2022-23 (8522/E8)
Open Tender
Civil Works
Item Rate
180 days
Pachmarhi MP
As per tender documents
8 documents required · 8 mandatory
₹500
AGE Indpt Pachmarhi
₹11,700
Yes
10 Mar 2023
30 Dec 2022
6 Feb 2023
30 Dec 2022
3 Feb 2023
20 Jan 2023
Amount
Supplying, installing and commissioning of diesel generating set of capacity 7.5 KVA incorporating Diesel Engine developing 10 BHP @ 1500 RPM complete with standard accessories coupled as per ISO 8528. Alternator rated at 6 KW / 7.5 KVA 415 V, 0.8PF, noise level < 75 dbA @ 1 mtr at 75% load under free field conditions, mounted on base frame complete with inbuilt fuel tank and battery 2 No 12 Volt including auto main failure (AMF) panel with Acoustic Enclosure - (NAL Approved) complete all cosisting of DG set control relay type BE2 AMF of logic controller designed for the control emergency and standby power supply systems. The function of AMF control panel to start/ stop relay element allows the automatic starting when power fails/ main return, engine and aloternator supervision and annunciator in LCD display suitable for 7.5 KVA DG set complete with 2 years warranty all as directed. Make : Kirloskar or equivalent as approved.
PRIMEMOVER : Suitable for driving 7.5 KVA alternator Air cooled producing not less than 10 BHP @ 1500 RPM coupled and conforming to IS : 10001/10002, rated output as per ISO 8528-1,Bosch HPCR fuel system with A1 class electronic governing, dual filter system, plate type lub oil cooler, 1500 RPM pedistal support with anti vibration pad for continous running capable of taking capable of taking 10% over load for one hour in any 12 hrs operation with following accessories : Make : Kirloskar or equivalent as approved.
ALTERNATOR : Technologies capacity of 7.5 KVA at 0.8 PF brush less, screen proceted, revolving field. self exicited self regulated, conforming to IS/IEC 60034-1, 3 phase reconnectable winding with 12 terminals brought out for connection, 50 HZ, 415 volt four wire screen protected drip proof free continuous rating to complete with automatic voltage regulator between normally lagging or set voltage from no load to full load. Make : Stamford or equivanent as approved.
ACOUSTIC ENCLOSURE : Specially designed to meet stringent MoEF /CPCB norms of 75dBA @ 1 mtr at 75% load under free field conditions. Acoustic enclosure is made of CRCA sheets in munsel green shade and a structural /sheet metal base frame painted in black by using high quality noise absorbant and fire-retardant grade acoustic insulation material (PU foam) complying to IS 8183 with two point lifting hook for handling at site.
Make : Kirloskar or equivalent as approved.
Supply, laying & testing cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 3.5 core 35 Sqmm complete all as directed. Make : Havells/ Polycab/ RR kabel
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil.
Returning, filling in, including spreading, levelling, watering and well ramming in not exceeding 25 cm thick complete.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point as directed.
Material and labour for narmada river sand, unwashed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete all as specified and directed.
Supply and laying unreinforced precast concrete cable cover, class LV, type 1 with flat, size 250 mm x 150 mm x 40 mm complete all as directed at site. Make Mehtab or equivalent.
Supply, commissioning, installation and testing of monoblock pump set, electric 415 volts, three phase, 3000 RPM, suitable to deliver 3000 - 1200 LPM at 6 - 76 m head, having inlet/outlet size 65mm X 65mm mounted on common steel base frame of minimum capacity 7.5 HP including making electrical and water supply connection (suction and delivery line) with and including foundation as per manufacturer design including taking out old unserviceable monoblock pump set of capacity 7.5 HP after disconnecting suction, delivery and electrical connections and depositing to E/M store yard complete all as specified and directed.
submersible pump, electric driven 415 V, 3 Phase suitable for 200/250 mm dia bore well (Casing pipe size 200/250 mm) supply and install complete of capacity 15 HP with LPM 740-30 at head 90-285m .
M/S RAKESH TRADERS
M/S INDIA ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .