| 1 | L1₹29.5 LAccepted-AOC ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹36.6 L+₹5.3 L (17.0%)Rejected-Finance NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L2 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
17 Jun 2023, 6:00 pmClosed
GE (AF) Jaisalmer
GE (AF) Jaisalmer
REPAIR/MAINT OF WATER SUPPLY INSTALLATION AT VARIOUS LOCATION AND REPAIR /MAINT OF FIRE HYDRANT SYSTEM AND OTHER ALLIED WORK AT AIR FORCE STATION JAISALMER
2023_MES_592970_2
8898/GE/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Jaisalmer
As per Tender documents
7 documents required · 7 mandatory
₹500
GE (AF) Jaisalmer
₹66,000
Yes
30 Jun 2023
25 May 2023
19 Jun 2023
25 May 2023
17 Jun 2023
3 Jun 2023
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc or for laying of cables, pipes, erection of poles, structs/stays etc not exceeding 10 sqm and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified.
Removal of excavated soil/ material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified.
Rectification of leakaging in water main pipe line by necessary excavation (upto one length of 6.00 RM) in any type of soil, in any situation/depth including bailing out leakage water by suitable measures, repair to existing DI/CI pipe following sizes by changing rings of same size or melting the lead with the help of burner/blower including taking out old spun yarn and re-jointing with & including additional quantity of Pig lead required and good quality of spun yarn, lead wool ring etc and testing of joint including dewatering complete all as specified and directed for the following:- Note: Cost of JCB for lifting of pipe for repair T&P required for removing water will be part of quoted rates.
80mm bore CI/DI Pipe lines
100mm bore CI/DI Pipe lines
150mm bore CI/DI Pipe lines
200mm bore CI/DI Pipe lines
300mm bore CI/DI Pipe lines
Rectification of leakage in water main pipe line including necessary excavation in any type of soil, in any situation including bailing out leakage water by suitable measures, repair to existing GI pipes pipes 15/20mm bore and cutting threading, for addition & alternation and for insertion of fittings/accessories (bend, elbow & Tee) complete all as specified and directed. Note for serial item No. 5.00 to 10.00:- (i) The rate is deemed to include for one fitting/special (complete unit) as required at site. (ii) Rate quoted shall be deemed to be inclusive of necessary dewatering and excavation (Upto one length of 6 RM) filling making good the existing surfaces with the necessary T&P, accessories of appropriate size as required complete all as directed.
Rectification of leakage in water main pipe line including necessary excavation in any type of soil, in any situation including bailing out leakage water by suitable measures, repair to existing GI pipes pipes 25mm bore and cutting threading, for addition & alternation and for insertion of fittings/accessories (bend, elbow & Tee) complete all as specified and directed .
Rectification of leakage in water main pipe line including necessary excavation in any type of soil, in any situation including bailing out leakage water by suitable measures, repair to existing GI pipes pipes 40mm bore and cutting threading, for addition & alternation and for insertion of fittings/accessories (bend, elbow & Tee) complete all as specified and directed .
Rectification of leakage in water main pipe line including necessary excavation in any type of soil, in any situation including bailing out leakage water by suitable measures, repair to existing GI pipes pipes 50mm bore and cutting threading, for addition & alternation and for insertion of fittings/accessories (bend, elbow & Tee) complete all as specified and directed.
Rectification of leakage in water main pipe line including necessary excavation in any type of soil, in any situation including bailing out leakage water by suitable measures, repair to existing GI pipes pipes 80mm bore and cutting threading, for addition & alternation and for insertion of fittings/accessories (bend, elbow & Tee) complete all as specified and directed.
Rectification of leakage in water main pipe line including necessary excavation in any type of soil, in any situation including bailing out leakage water by suitable measures, repair to existing GI pipes pipes 100mm bore and cutting threading, for addition & alternation and for insertion of fittings/accessories (bend, elbow & Tee) complete all as specified and directed.
Galvanized steel water tubing medium grade of 25mm bore with & including all necessary fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections of existing pipe, complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.
Galvanized steel water tubing medium grade of 50mm bore with & including all necessary fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections existing pipe, complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.
Galvanized steel water tubing medium grade of 80mm bore with & including all necessary fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections of existing pipe, complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.
Gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 50mm bore pipe line fixed as in repair complete all as specified and directed.
Gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 40mm bore pipe line fixed as in repair complete all as specified and directed.
Gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 25mm bore pipe line fixed as in repair complete all as specified and directed.
Cast iron body Sluice valve heavy duty class ‘PN-1.6’, 80mm bore, ISI marked with confirming to IS-14846-2000, both flanged ends and drilled, high tensile stainless steel spindle, Cast Iron gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve of existing, complete all as specified and directed.
Cast iron body sluice valve heavy duty class ‘PN-1.6’, 100mm bore, ISI marked with confirming to IS-14846-2000, both flanged ends and drilled, high tensile stainless steel spindle, Cast Iron gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve of 100mm bore, complete all as specified and directed.
Cast iron body sluice valve heavy duty class ‘PN-1.6’, 150mm bore, ISI marked with confirming to IS-14846-2000, both flanged ends and drilled, high tensile stainless steel spindle, Cast Iron gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve of existing, complete all as specified and directed.
Cast iron body sluice valve heavy duty class ‘PN-1.6’, 200mm bore, ISI marked with confirming to IS-14846-2000, both flanged ends and drilled, high tensile stainless steel spindle, Cast Iron gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve of existing, complete all as specified and directed.
Cast iron body sluice valve heavy duty class ‘PN-1.6’, 300mm bore, ISI marked with confirming to IS-14846-2000, both flanged ends and drilled, high tensile stainless steel spindle, Cast Iron gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve of existing, complete all as specified and directed.
Repair to sluice valve of any size by opening it loosing nut bolts and repair its spindle as threaded on lathe machine and making its spindle fixing again to sluice valve and gland packing and changing its nuts bolts required size as sluice valve size complete all as specified and directed.
Construction of stone masonary valves pit of size 1500mm x 1500 mm x 1500mm (internal dimention of chamber) made with bulit in cement mortar 1.6 for sluice valve chamber including necessary excavation, foundation concrete in PCC 1:4:8 type D2 using 40mm graded stone aggregate for foundation and 15mm thick inside cement plaster with cement mortar 1:4 with floating coat of near cement, PCC coping type B1 (1:2:4) using 20mm graded stone aggregate including necessary form work with MS frame with angle iron 50x50x6 mm and cover of MS sheet 3.15mm thick including tarring and painting (where required) the steel surface with two coats of synthetic enamel paint over a coat of red oxide prime including locking arrangement complete all as specified & directed.
Construction of stone masonary valves pit of size 1200mmx 1200mm x 1200mm (internal dimention of chamber) made with bulit in cement mortar 1.6 for sluice valve chamber including necessary excavation, foundation concrete in PCC 1:4:8 type D2 using 40mm graded stone aggregate for foundation and 15mm thick inside cement plaster with cement mortar 1:4 with floating coat of near cement, PCC coping type B1 (1:2:4) using 20mm graded stone aggregate including necessary form work with MS frame with angle iron 50x50x6 mm and cover of MS sheet 3.15mm thick including tarring and painting (where required) the steel surface with two coats of synthetic enamel paint over a coat of red oxide prime including locking arrangement complete all as specified & directed.
Cast Iron foot valve of size 50mm bore (ISI marked) flanged end/threaded type (heavey grade) with rubber insertion sheet 3mm thick, nuts, bolts and washers including taking down old existing unserviceable foot valve complete all as specified & directed.
Cast Iron foot valve of size 80mm bore (ISI marked) flanged end/threaded type (heavey grade) with rubber insertion sheet 3mm thick, nuts, bolts and washers including taking down old existing unserviceable foot valve complete all as specified & directed.
Cast Iron foot valve of size 100mm bore (ISI marked) flanged end/threaded type (heavey grade) with rubber insertion sheet 3mm thick, nuts, bolts and washers including taking down old existing unserviceable foot valve complete all as specified & directed.
Cast Iron foot valve of size 150mm bore (ISI marked) flanged end/threaded type (heavey grade) with rubber insertion sheet 3mm thick, nuts, bolts and washers including taking down old existing unserviceable foot valve complete all as specified & directed.
Cast Iron foot valve of size 200mm bore (ISI marked) flanged end/threaded type (heavey grade) with rubber insertion sheet 3mm thick, nuts, bolts and washers including taking down old existing unserviceable foot valve complete all as specified & directed.
Preparation of existing old painted surface of any description such as suction and delivery line at any height (strictly existing shade) complete after scratching existing rusted surface then applyingtwo coats of synthetic enamel paint over one coat of red oxide primer (superior quality) and in blue colour all around the pipe line complete all as specified and directed.
10mm thick gland packing in small packets for valves and motor pumps complete all as specified and directed.
12mm thick gland packing in small packets for valves and motor pumps complete all as specified and directed.
15mm thick gland packing in small packets for valves and motor pumps complete all as specified and directed.
20mm thick gland packing in small packets for valves and motor pumps complete all as specified and directed.
Rubber gasket tyton joint (push on joint) including rubber ring suitable for 80mm bore socket & spigot CI pipe and fittings including taking down old unserviceable complete all as specified and directed.
Rubber gasket tyton joint (push on joint) including rubber ring suitable for 100mm bore socket & spigot CI pipe and fittings including taking down old unserviceable complete all as specified and directed.
Rubber gasket tyton joint (push on joint) including rubber ring suitable for 150mm bore socket & spigot CI pipe and fittings including taking down old unserviceable complete all as specified and directed.
Rubber gasket tyton joint (push on joint) including rubber ring suitable for 200mm bore socket & spigot CI pipe and fittings including taking down old unserviceable complete all as specified and directed.
Rubber gasket tyton joint (push on joint) including rubber ring suitable for 300mm bore socket & spigot CI pipe and fittings including taking down old unserviceable complete all as specified and directed.
De-watering the existing RCC under ground/semi under ground sump of 10000 Gallon capacity and scratching and cleaning all internal surfaces of roof, walls, pillar and floor to remove scales, mud & other foreign material and applying a solution of potossium permanganate (KMnO4), scrubbing with water using jute/bushes and washing the surfaces with mixture of bleaching powder and fresh water, finally washing the surfaces with fresh water and treating all internal surfaces with providing two coats of anti corrosive paint including repair to vent pipes including providing wire mesh and clamps complete and writing capacity of sump, date of cleaning & due date of next cleaning in thick synthetic enamel paint on outer surface of sump in block capital letters of height 25cm complete all as specified and directed. Notes for serial item No. 40.00 to 47.00:- (i) The mixture of bleaching powder & water for cleaning shall be prepared by mixing 250gm of bleaching powder in 10 litres of fresh water. (ii) All inlets/outlets/over flow/wash out connections shall be cleaned. Any leakage in joints shall be made good as directed and quoted rate also includes this aspect. (iii) The existing water, water used for cleaning etc shall be bailed out at the nearest open drain available. (iv) Any damage occurred to the assets during cleaning etc shall be made good by the contractor at his own cost. (v) All protective & safety measures for workmen shall be responsibility of the contractor. The quoted rate shall be deemed to include for this provision. (vi) If work is not done upto satisfactorly level of concerned JE/AGE (E/M), the work will be redone upto the mark without any extra cost.
De-watering the existing RCC under ground/semi under ground sump of 20000 Gallon capacity and scratching and cleaning all internal surfaces of roof, walls, pillar and floor to remove scales, mud & other foreign material and applying a solution of potossium permanganate (KMnO4), scrubbing with water using jute/bushes and washing the surfaces with mixture of bleaching powder and fresh water, finally washing the surfaces with fresh water and treating all internal surfaces with providing two coats of anti corrosive paint including repair to vent pipes including providing wire mesh and clamps complete and writing capacity of sump, date of cleaning & due date of next cleaning in thick synthetic enamel paint on outer surface of sump in block capital letters of height 25cm complete all as specified and directed.
De-watering the existing RCC under ground/semi under ground sump of 25000 Gallon capacity and scratching and cleaning all internal surfaces of roof, walls, pillar and floor to remove scales, mud & other foreign material and applying a solution of potossium permanganate (KMnO4), scrubbing with water using jute/bushes and washing the surfaces with mixture of bleaching powder and fresh water, finally washing the surfaces with fresh water and treating all internal surfaces with providing two coats of anti corrosive paint including repair to vent pipes including providing wire mesh and clamps complete and writing capacity of sump, date of cleaning & due date of next cleaning in thick synthetic enamel paint on outer surface of sump in block capital letters of height 25cm complete all as specified and directed.
De-watering the existing RCC under ground/semi under ground sump of 50000 Gallon capacity and scratching and cleaning all internal surfaces of roof, walls, pillar and floor to remove scales, mud & other foreign material and applying a solution of potossium permanganate (KMnO4), scrubbing with water using jute/bushes and washing the surfaces with mixture of bleaching powder and fresh water, finally washing the surfaces with fresh water and treating all internal surfaces with providing two coats of anti corrosive paint including repair to vent pipes including providing wire mesh and clamps complete and writing capacity of sump, date of cleaning & due date of next cleaning in thick synthetic enamel paint on outer surface of sump in block capital letters of height 25cm complete all as specified and directed.
De-watering the existing RCC under ground/semi under ground sump of 75000 Gallon capacity and scratching and cleaning all internal surfaces of roof, walls, pillar and floor to remove scales, mud & other foreign material and applying a solution of potossium permanganate (KMnO4), scrubbing with water using jute/bushes and washing the surfaces with mixture of bleaching powder and fresh water, finally washing the surfaces with fresh water and treating all internal surfaces with providing two coats of anti corrosive paint including repair to vent pipes including providing wire mesh and clamps complete and writing capacity of sump, date of cleaning & due date of next cleaning in thick synthetic enamel paint on outer surface of sump in block capital letters of height 25cm complete all as specified and directed.
De-watering the existing RCC under ground/semi under ground sump of 150000 Gallon capacity and scratching and cleaning all internal surfaces of roof, walls, pillar and floor to remove scales, mud & other foreign material and applying a solution of potossium permanganate (KMnO4), scrubbing with water using jute/bushes and washing the surfaces with mixture of bleaching powder and fresh water, finally washing the surfaces with fresh water and treating all internal surfaces with providing two coats of anti corrosive paint including repair to vent pipes including providing wire mesh and clamps complete and writing capacity of sump, date of cleaning & due date of next cleaning in thick synthetic enamel paint on outer surface of sump in block capital letters of height 25cm complete all as specified and directed.
De-watering the existing RCC under ground/semi under ground sump of 250000 Gallon capacity and scratching and cleaning all internal surfaces of roof, walls, pillar and floor to remove scales, mud & other foreign material and applying a solution of potossium permanganate (KMnO4), scrubbing with water using jute/bushes and washing the surfaces with mixture of bleaching powder and fresh water, finally washing the surfaces with fresh water and treating all internal surfaces with providing two coats of anti corrosive paint including repair to vent pipes including providing wire mesh and clamps complete and writing capacity of sump, date of cleaning & due date of next cleaning in thick synthetic enamel paint on outer surface of sump in block capital letters of height 25cm complete all as specified and directed.
De-watering the existing RCC over head water reservoir of 50000 Gallon capacity at 60 feet staging and scratching and cleaning all internal surfaces of roof, walls, pillar and floor to remove scales, mud & other foreign material and applying a solution of potossium permanganate (KMnO4), scrubbing with water using jute/bushes and washing the surfaces with mixture of bleaching powder and fresh water, finally washing the surfaces with fresh water and treating all internal surfaces with providing two coats of anti corrosive paint including repair to vent pipes including providing wire mesh and clamps complete and writing capacity of reservoir, date of cleaning & due date of next cleaning in thick synthetic enamel paint on outer surface of sump in block capital letters of height 25cm complete all as specified and directed.
Cuttings grass/herbs near installation, plant and pumps complete cleaning of installation, valve chamber and cleaning of installation including necessary tools and safety measures where ever complete all as specified and directed.
1000 Litre capacity Rotational moulded polyethylene water storage tanks triple layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including dismentling & taking down old unserviceable water tank capacity 1000 litre complete as specified in SSR Part-I.
500 Litre capacity Rotational moulded polyethylene water storage tanks triple layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including dismentling & taking down old unserviceable water tank capacity 500 litre complete as specified in SSR Part-I.
80mm bore CI/DI pipe lines rectification of Leakages by necessary excavation (upto one length of 6.00 RM) in any type of soil, in any situation/depth including bailing out leakage water by suitable measures with MS clamp of suitable size including rubber cushioning, 5mm thick and 100mm wide with hole drilled for nut bolts including suitable nuts and bolts for rectification of leakages complete all as specified and directed. Note for serial item No.51.00 to 55.00 : Cost of JCB for lifting of pipe for repair T&P for removing of water are inclusive in the unit rate quoted by contractor .
100mm bore CI/DI pipe lines rectification of Leakages by necessary excavation (upto one length of 6.00 RM) in any type of soil, in any situation/depth including bailing out leakage water by suitable measures with MS clamp of suitable size including rubber cushioning, 5mm thick and 100mm wide with hole drilled for nut bolts including suitable nuts and bolts for rectification of leakages complete all as specified and directed.
150mm bore CI/DI pipe lines rectification of Leakages by necessary excavation (upto one length of 6.00 RM) in any type of soil, in any situation/depth including bailing out leakage water by suitable measures with MS clamp of suitable size minimum 150mm including rubber cushioning, 5mm thick and 100mm wide with hole drilled for nut bolts including suitable nuts and bolts for rectification of leakages complete all as specified and directed.
200mm bore CI/DI pipe lines rectification of Leakages by necessary excavation (upto one length of 6.00 RM) in any type of soil, in any situation/depth including bailing out leakage water by suitable measures with MS clamp including rubber cushioning, 5mm thick and 150mm wide with hole drilled for nut bolts including suitable nuts and bolts for rectification of leakages complete all as specified and directed.
300mm bore CI/DI pipe lines rectification of Leakages by necessary excavation (upto one length of 6.00 RM) in any type of soil, in any situation/depth including bailing out leakage water by suitable measures with MS clamp of suitable size including rubber cushioning, 5mm thick and 150mm wide with hole drilled for nut bolts including suitable nuts and bolts for rectification of leakages complete all as specified and directed.
Cast iron body butterfly valve heavy duty, 80mm bore, ISI marked with confirming to IS-13095-1991, both flanged ends and drilled, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable valve, complete all as specified & directed.
Cast iron body butterfly valve heavy duty, 100mm bore, ISI marked with confirming to IS-13095-1991, both flanged ends and drilled, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable valve, complete all as specified & directed.
CI reflex valve/Non return valve (NRV) of size 150mm bore, cast iron body, (ISI marked) with confirming to IS 5312 (Part-1) : 2004, heavy duty, both ends flanged and drilled, including nuts, bolts, washer and neoprene rubber gasket joint including dismantling & taking out old unserviceable non return valve complete all as specified and as directed.
CI reflex valve/Non return valve (NRV) of size 100mm bore, cast iron body, (ISI marked) with confirming to IS 5312 (Part-1) : 2004, heavy duty, both ends flanged and drilled, including nuts, bolts, washer and neoprene rubber gasket joint including dismantling & taking out old unserviceable non return valve complete all as specified and as directed.
CI reflex valve/Non return valve (NRV) of size 80mm bore, cast iron body, (ISI marked) with confirming to IS 5312 (Part-1) : 2004, heavy duty, both ends flanged and drilled, including nuts, bolts, washer and neoprene rubber gasket joint including dismantling & taking out old unserviceable non return valve complete all as specified and as directed.
Earthing complete with galvanized steel earth plate electrode 60cmx 60cm x6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/ equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15mm bore 7.50 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 23 mm thick sand stone slab pit cover complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium conductor 1100 Volt grade cross sectional area 95 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium conductor 1100 Volt grade cross sectional area 50 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old u/s cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium conductor 1100 Volt grade cross sectional area 25 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old u/s cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium conductor 1100 Volt grade cross sectional area 16 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old u/s cable complete all as specified and directed.
Stone patti 40 to 50mm thick rough dressed Jodhpur stone slab cover in trenches for protection of cable 25 to 35cm wide and not less than 60cm in length laid dry abutting each other with gap between adjacent slab not exceeding 10mm over sand cushioning including taking down old complete all as specified and directed.
Dry tibba sand cushioning to underground cable provided with a layer of 8cm deep before laying cable and 15cm after laying of cable and punned to 18cm after laying of cable and cover for protection of underground cable complete all as specified and directed. Notes :- (i) Approved dry sand free from vegetation, grass and other deleterious substances shall be used. (ii) For the purpose of payment only punned thickness shall be measured for payment.
Testing of water sample at authorised government laboratory for biological fittness of water on monthly basis including glass bottle for collection of sample of water to be collected from wherever directed by Engr-In-Charge. (Note : (i) Water sample includes area such as Army Pump House, Rajwai Pump House, City Pump House, Domestic (SMQ Pump House), 03 AFRU (Tube Well, RO Plant), 43 WEU (A) Ramgarh (IG Canal Pump House, RO Plant), Tube Well at 265 SU, UAV, WSA, 15 AFH), RO Plant at 15 AFH (Twice in a year). (ii) Collection of sample from all the places at a time will be considered as one Job each time complete all as specified.
Switch air break, gang operated, triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 400 amps including taking down old unserviceable all as specified and directed.
LED street light fittings 90W, 230V complete including driver, lences and all other connected accessories including dismantling and taking down old unserviceable complete all as specified and directed.
LED flood light 100W, 230V complete with all fittings and fixtures including disconnecting and taking down old unserviceable flood light complete all as specified and directed.
Maintenance and servicing of DG Set of capacity 63 KVA complete including draining out of Diesel from tank, cleaning the tank throughly and refilling the drained out diesel, draining out engine oil from the chamber, cleaning the chamber throughly and refilling the same with new engine oil to required level, replacing the fuel filter, lubricating oil filter, check & clean Air cleaner, change air cleaner elements, check coolant level & make up the same, drain the fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the unserviceable brass connectors for batteries, cleaning of battery terminals & applying petrolium jelly to battery terminal posts & brass connectors, changing of V-Belts, changing of rubber housing and clips of air cleaner, checking of exhaust leakage & repairing the same, Governor, breathers etc. adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/ coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG set with accessories as prescribed by the maufacturer and test for satisfactory running of DG set for two hour at connected load & record shall be made in respect of RPM, oil pressure, oil temperature, coolant temperature, voltage, frequency, load current, battery charging, fuel consumption etc. complete all as specified and directed.
Maintenance and servicing of DG Set of capacity 100 KVA to 160 KVA complete including draining out of Diesel from tank, cleaning the tank throughly and refilling the drained out diesel, draining out engine oil from the chamber, cleaning the chamber throughly and refilling the same with new engine oil to required level, replacing the fuel filter, lubricating oil filter, check & clean Air cleaner, change air cleaner elements, check coolant level & make up the same, drain the fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the unserviceable brass connectors for batteries, cleaning of battery terminals & applying petrolium jelly to battery terminal posts & brass connectors, changing of V-Belts, changing of rubber housing and clips of air cleaner, checking of exhaust leakage & repairing the same, Governor, breathers etc. adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/ coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG set with accessories as prescribed by the maufacturer and test for satisfactory running of DG set for two hour at connected load & record shall be made in respect of RPM, oil pressure, oil temperature, coolant temperature, voltage, frequency, load current, battery charging, fuel consumption etc. complete all as specified and directed.
Load change over switch 415V, 4 Pole of capacity 200 Amp including taking down old unserviceable complete all as specified and directed.
Load change over switch 415V, 4 Pole of capacity 400 Amp including taking down old unserviceable complete all as specified and directed.
First Aid box made up of wooden frame and front door with transparent glass including hinges and locking arrangements of minimum size 300x200x100mm containing following items :- (a) Dettols bottle100 ml 02 bottles (b) Antiseptic Ointment 100 mg (c) Crocin tabletes 40 strips ( containings 10 Tablets each. (d) Hydrogen peroxide 50 ml 01 bottle (e) Cotton small rolls 2 Nos (f) Cotton strip small roll 04 Nos (g) Move tube 01 Nos
PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in foundation etc complete all as specified and as directed .
12.5 HP motor
20 HP motor
25 HP motor
30 HP motor
40 HP motor
Mild steel ERW (Electric Resistance Welded) pipe water tubing heavy grade of 300mm bore with & including all fittings complete, laid in trenches/wall/ floor, including taking down old unserviceable pipe and connections complete all as specified and directed. Make:-Jindal/Parkash surya/ Tata
Mild steel ERW (Electric Resistance Welded) pipe water tubing heavy grade of 200mm bore with & including all fittings complete, laid in trenches/wall/floor, including taking down old unserviceable pipe and connections complete all as specified and directed. Make:-Jindal/Parkash surya/ Tata
Mild steel ERW (Electric Resistance Welded) pipe water tubing heavy grade of 150mm bore with & including all fittings complete, laid in trenches/wall/floor, including taking down old unserviceable pipe and connections complete all as specified and directed. Make:-Jindal/Parkash surya/ Tata
Mild steel ERW (Electric Resistance Welded) pipe water tubing heavy grade of 100mm bore with & including all fittings complete, laid in trenches/wall/floor, including taking down old unserviceable pipe and connections complete all as specified and directed. Make:-Jindal/Parkash surya/ Tata
Mild steel ERW (Electric Resistance Welded) pipe water tubing heavy grade of 80mm bore with & including all fittings complete, laid in trenches/wall/floor, including taking down old unserviceable pipe and connections complete all as specified and directed. Make:-Jindal/Parkash surya/ Tata
Comprehensive maint and servicing of Jockey pump of capacity 15 HP complete all as specified and directed.
Comprehensive maint and servicing of electrical operated fire pump of capacity 60-75 HP complete all as specified and directed.
Comprehensive maint and servicing of deisel engine driven fire pump including of diesel engine of capacity 60-75 HP with and including replacement of following parts :- (a) Replacement of fuel filter (b) Replacement of oil filter (c) Replacement of Engine oil (d) Replacemnt of oil seals (e) Testing of diesel engine after servicing
Rewinding of electrically operated fire pump motor of capcity 75 HP, 2850 LPM and 70 M head complete all as specified and directed.
Cast iron body non return butterfly valve heavy duty, 150mm bore, ISI marked with confirming to IS-13095-1991, both flanged ends and drilled, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable valve, complete all as specified & directed.
Fire brigade inlet connection 2 way made out of stainless steel as per IS :5290 Type 'B' including taking down existing complete all as specified and directed. Make :- Minimex/ Firex/Newage/Suprex
Hydrant valve size 63mm double headed 63 mm made out of stainless steel including taking down old unserviceable valve complete all as specified and directed. Make :- Minimex/ Firex/ Newage/ Suprex
Hose reel drum 36m long alongwith rubber pipe of minimum size 20 mm dia including shorts brass nozzle including taking down old unserviceable complete all as specified and directed. Make :- Minimex/ Firex/Newage/Suprex
Hose box including accessories like 63 mm hose pipe 30 m length , short nozzle and any other accessories required at site for smooth functioning of the system made of 18 gauge MS sheet 800mm x 600mm x 250mm with double door with 4.00mm thick glasses and door frame made of 16 gauge Mild Steel Sheet painted fire red outside and brilliant white inside yard including taking down old unserviceable complete all as specified and directed.
Yard hydrant Post / Stand Post 80mm dia GI / MS both flanged type 1.5m height with all accessories including taking down old unserviceable complete all as specified and directed. Make :- Minimex/Safex/Godrej & Boyce
2000 Litre capacity Rotational moulded polyethylene water storage tanks triple layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including dismentling & taking down old unserviceable existing water tank complete as specified in SSR Part-I.
Earthing complete with galvanished earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5 deep below normal ground level and connected to galvanished iron earth lead strip 32mmx6mm upto 7.50 metre, by means of GI nuts, bolt, check nuts, washers, thimbles, etc as shown in electrical plate No. 5 SSR Part-I and connection to main switch board or panel and testing on completion including excavation and earth work in any type to soil, returning fitting in and removal of surface spoil to a distance not exceeding 50 metre, PCC chamber (1:3:6) type C-2, charcoal and salt mixed layer 15cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe light grade 20mm bore for watering and 50mm bore GI pipe light grade for earth wire protection fixed with poles with two clamps, made from earth lead strip 32mm x 6mm, bolts, nuts and washers, 80mm thick pre cast RCC cover 1:2:4, type B-1, reinforced with hard drawn steel wire fabric wieghing not less than 4 Kg/Sqm in lieu of CI cover etc including taking down old earth complete all as specified and directed. Note: (i) The unit rate shall be deemed to included for Test point, 32mmx6mm GI strip from top of the earth plate upto 7.50m above ground level. In case, GI protection pipe required is less than 7.50m, no price adjustment shall be made. (ii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junctions, elbow etc shall be deemed to be included in the unit rate quoted by the tenderer.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium conductor 1100 Volt grade cross sectional area 120 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old u/s cable complete all as specified and directed.
Re-wiring and interlocking of Fire panels, repair/servicing of pump starters, cleaning of contactors terminals, checking of sensors and testing on completion, including disconnecting & taking down old unserviceable complete all as specified & directed.
MCCB, 4 Pole, 200 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed.
MCCB, 4 Pole, 160 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed.
MCCB, 4 Pole, 63 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed.
Anil Builders
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .