Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.1 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹21.5 L+₹1.1 L (5.35%)Rejected-Finance P 45 KHIRODE VIDYA BINOD AVENUE KOLKATA 700003 | KOLKATA | WEST BENGAL | 700003 | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹21.5 L+₹1.1 L (5.35%)Rejected-Finance 186 B DIAMOND HARBOUR ROAD KOLKATA 700 060 | KOLKATA | WEST BENGAL | 700060 | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹22.0 L+₹1.6 L (7.63%)Rejected-Finance | L4 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
12 Jul 2023, 6:00 pmClosed
VIVEK TANENIA
GARRISON ENGINEER (CENTRAL) KOLAKTA T37 NAPIER ROAD HASTING KOLKATA 700022
REPAIR AND MAINT OF SUBMAIN WIRING MCCBS, DBS, BUS BARS, BUILDING EARTHING AND WALL CABELING OF MAP PHASE-II BLDG AT OD ALIPORE AND RASPUNJA MIL CAMP UNDER GE (CENTRAL) KOLKATA
2023_MES_602401_1
8607/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
KOLKATA
AS PER TENDER DOCUEMNTS
9 documents required · 9 mandatory
₹500
GE (C) KOLKATA
₹40,000
Yes
18 Sept 2023
9 Jun 2023
13 Jul 2023
9 Jun 2023
12 Jul 2023
30 Jun 2023
9 Jun 2023 - 24 Jun 2023
Amount
Taking down point wiring (light, fan, socket and power complete including fixtures and fittings such as switches ceiling roses, pendents , regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody for refixing or for taking credit (credit for above items should be made as per conditions separately) and making good distrubed surfaces of walls, floors, etc.complete all as directed by Engineer-in-Charge.
M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium duty with all accessories including fabricated 1.6 mm thick MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets, regulator etc including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fan point controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan/call bell point/ Switch socket outlet 5 amps complete all as specified and as directed. Note: (i) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (ii) Cutting Chases pinning shall be measured and paid separately under relevant item of Sch A
All as per item No 2.00 here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge.
All as per item No. 2.00 here-in-before but one 3 pin 5 amps switch socket outlet on the independent board with other switch complete all as specified and directed by Engineer-in-charge.
M&L Point wiring with 2.5 sqmm (Nominal Area) PVC insulated stranded single core unsheathed FRLSH copper conductor cable 1100 Volts grade drawn through with and including PVC concealed conduit 20mm dia medium duty with all fittings and accessories of casing caping (like Tee, Bend etc) complete fixed to walls / ceiling etc with and including 2.5 Sqmm (nominal area) PVC insulated unsheathed, stranded, single core FRLSH copper cable as earth continuity wire connecting to common earth point (including supply & fixing of 1.6 mm thick pressed mild steel terminal boxes of suitable size with 3 mm thick PVC /plastic laminated sheet, top cover suitable sizes of brass screws and washers etc. for mounting sockets for 5 pin, 16 Amp socket outlet on independent board complete all as specified and directed. Note: (i) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (ii) Cutting Chases pinning shall be measured and paid separately under relevant item of sch A
S&F Switch piano, flush type, SP, one way, 5/6 Amps 230/240 Volts, white/ivory finish complete all as specified and directed.
S&F Switch socket combination multipurpose 2 in 1, 3 pin 6 Amps 230/240 volt flush type complete all as specified and as directed.
S&F Socket outlet 3/5 pin, 6 Amps, 240 volt flush type complete all as specified and as directed.
S&F Switch socket combination multipurpose 2 in 1, 3 pin 15 Amps 230/240 volt flush type complete all as specified and as directed.
S&F Lamp holder suitable for batten fittings complete all as specified and directed by the Engr-in-Charge.
S&F Ceiling rose PVC/polycarbonate ,65x 50mm, three terminals 240 volts complete all as specified and as directed.
Supply and fix PVC insulated, stranded copper electric cable, 2.5 Sqmm 2 core drawn into the steel tubular pole by drilling holes above the junction box and another holes near street light bracket including taking out old unserviceable copper wire complete all as specified and as directed.
Repair / replacement nut bolts, thimbles, rusted joints, bus bar in high rise buildings each floor complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 32x6 as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip proected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and as directed.
Supply and fix LED street light luminaries 45 watt fixed with bracket made out of 40mm dia light grade GI pipe bent to shape of 45º 1.5 m long inluding all accessories and necessary connection after taking down old unserviceable one complete all as specified and as directed by the Engr-in-Charge. Make:- Crompton cat part No. LSTS-45-CDL or Make:- Bajaj Cat part No. ENXT P 45L WW CR PC SD. or Make:- Surya cat part No. SLE UL 45W IP66 LXN
Supply and fix LED street light luminaries 90 watt fixed with bracket made out of 40mm dia light grade GI pipe bent to shape of 45º 1.5 m long inluding all accessories and necessary connection after taking down old unserviceable one complete all as specified and as directed by the Engr-in-Charge. Make:- Crompton cat part No. LSTP-90-CDL or Make:- Bajaj Cat part No. BRTFG 90W LED CR WW. or Make:- Surya cat part No. SLE UL 90W IP66 LXN
Taking down old burnt/unserviceable submain wiring with aluminum/copper conductor PVC insulated cable of any size drawn through PVC casing caping/ PVC Conduit pipe including GI wire accessories etc. and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 4.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 4.0 Sqmm as earth lead drawn into rigid non metalic PVC conduit of size 20 mm dia including all fittings complete all as specified and as directed. Note:- Two runs of 4 Sqmm conductor as main wire and one run of 4 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit.
M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 6.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 6.0 Sqmm as earth lead drawn into rigid non metalic PVC conduit of size 25 mm dia including all fittings complete all as specified and as directed. Note:- Two runs of 6 Sqmm conductor as main wire and one run of 6 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit.
Material and labour Preparation of old painted surface of existing steel tubular swaged pole 9 mtr long, cross arms, clamps, GI street light bracket etc and applying two coats of aluminium paint including writing pole number & bottom of pole painted with black paint with yellow strip around between the junction of aluminium paint and black paint complete all as specified and directed.
S&F Thermoplastic, polycarbonate cable terminal boxes, outdoor type of size 155mm x210mm x92mm alongwith MCB SP 6 to 32 Amps and fixed to pole with MS clamp made out of MS flat of section 25x 3mm including all necessary fittings and connection including taking down old unserviceable one complete all as directed by Enginner-in-Charge. Make:- Hansel Model No. KF 1616G or equivalent model from Sintex/ Universal.
S&F Thermoplastic, polycarbonate cable terminal boxes, outdoor type of size 93mm x93mm x 62mm alongwith MCB SP 6 to 32 Amps and fixed to pole with MS clamp made out of MS flat of section 25x 3mm including all necessary fittings and connection including taking down old unserviceable one complete all as directed by Enginner-in-Charge. Make:- Hansel Model No. KF 0200B or equivalent model from Sintex/ Universal.
S&F junction pole box made of high quality thermoplastic polycarbonate (shock proof ,rust free,corrosion free,acid and chemical resistant,fire retardant, having high impact strength, of IK 9, made of halogen and silica free recyclable material IP66/67 degree of protection UV resistant, having high graded internally embedded gasket made of poly urethane should withstand glow wire test at 960 degree centigrade should be flame retradant and self extingushing with switch gear assemblies as per IEC-439-1 the junction box should have 4 power terminal of 25 Sqmm and earth terminal along with SP MCB of 6 Amp fitted in it the dimension of box shall be 205x255x112 in mm (LxHxD) make hensel KF 2500 G make of MCB L&T. and fixing to tubular /PCC pole using MS flat of size 25 x 3mm with suitable nuts and bolds including taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge.
Taking down defective existing LED street lihgt/LED security light fittings of any type and any capacity from any height of pole/ any place and refitted the same in position after necessary fault finding/repair/replacement the defective components and making connection with copperwire 1.5 sqmm and PVC Connector block and testing complete Note:- LED Driver shall be measured and paid separately as supplied against respective items.
Supply only constant current LED Driver opertaing voltage 180v-270v-AC 50/60 Hz out put voltage 36V DC/2.8 Amp power factor 0.95 Make- Bajaj cat No BGD36 240 5Y or equivalent in philips/CG.
Supply and fix Timer switch of analogue type for street light fittings, module 1 including taking down old unserviceable one complete all as specified and as directed. Make:- L&T Cat part No. AUTS01ANA00 or equivalent model from make:- Schneider / ABB / SIEMENS
S&F MCCB, 250 Amps, 36kA, four pole with thermal and magnetic release adjustable type with necessary connection ,cutting welding of existing panel and making good the disturb surface including taking down old unserviceable one complete all as specified and as directed.
S&F MCCB, 200 Amps, 36kA, four pole with thermal and magnetic release adjustable type with necessary connection ,cutting welding of existing panel and making good the disturb surface including taking down old unserviceable one complete all as specified and as directed.
Taking out unserviceable UG cables of any type and any sizes from trenches etc and removing from the site of work complete all as specified and directed. Note:- (i) Serviceable bricks obtained shall be stacked properly for re-use. (ii) Excavation and earth work shall be measured and paid separately under relevant item of these schedule.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 25 Sqmm 3.5 core in trenches/ duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 35 Sqmm 3.5 core in trenches/ duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 95 Sqmm 3.5 core in trenches/ duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 120 Sqmm 3.5 core in trenches/ duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge.
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth for laying of cables/foundation of poles and getting out in soft /loose soil complete all as specified and directed.
Supply and laying dry coarse sand as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 Cm (15 Cm under the cable & 8 Cm over the cable) and gently punned down to 18 Cm thickness complete all as specified and as directed. Note:- Thickness after punning down shall be measured for payment.
Supply and laying in trenches Bricks, sub class 'B' over burnt (kiln burnt) old size bricks, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed.
Laying only in trenches Old serviceable bricks obtained from taking out old unserviceable XLPE cable, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed.
Returning filling in including spreading levelling watering and well rammming in layers not exc 25cm complete all as specified and directed.
Removing excavated materiasl not exc 50 mtr and depositing where directed at a level n.exc 1.5mtr above the starting point complete all as specified and direced.
M&L for Cutting roads / hard standing to a depth not less than 60 cm and not less than 45 cm wide for laying of GI pipe to draw the UG cable and making good the disturbed surfaces by filling of PCC (1:3:6) type C-2 using 40 mm graded stone aggregate and finished the surface even and smooth with out using extra cement and disposed off the surplus debris and soil to a distance not exc 50 m complete all as specified and as directed.
M&L for 100mm bore GI tubes light grade for cable protection supporting to poles with all fixing accessoires (clamps, nut, bolt and washer etc) complete all as specified and directed.
All as per item no 41.00 but 80 mm dia
All as per item no 41.00 but 50 mm dia
M&L Plain cement concrete (1:4:8) type D-2, using 40mm graded aggregate as in foundation base of pole and other similar location complete all as specified and as directed.
M&L Plain cement concrete (1:3:6) type-C-2 using 40mm graded aggregate including all necessary from work including demolition of old PCC/broken PCC complete all as specified and as directed.
M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in coping of pole/struts and other similar location etc with and including all necessary form work including demolition of old PCC/broken PCC complete all as specified & directed
S&F Aluminium strip 25x3.15mm with saddles and fixing screws etc for roof conductors and down conductors above ground incl taking down old unserviceable one complete all as specified and as directed.
S&F Air termination aluminium single pointed rod 12 mm dia, 300 mm long incl taking down old unserviceable one complete all as specified and as directed.
S&F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm,drilled and screwed including 3 Nos 8mm dia 25mm long hex. head screw incl taking down old unserviceable one complete all as specified and as directed.
M&L Danger notice plate of 1.6mm thick for HT 20x15cm mild steel sheet, vitreous enameled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts incl taking down old unserviceable one complete all as specified and as directed.
Supply and fix Straight through XLPE cable jointing kit 1100V ( Earthed) grade for indoor termination heat shrinkable type complete with jointing materials and accessories suitable for XLPE armoured aluminium conductor cable of size 25 Sqmm to 50 Sqmm 3.5 core including taking down old unserviceable one complete all as specified and as directed.
Supply and fix Straight through XLPE cable jointing kit 1100V ( Earthed) grade for indoor termination heat shrinkable type complete with jointing materials and accessories suitable for XLPE armoured aluminium conductor cable of size 70 Sqmm to 120 Sqmm 3.5 core including taking down old unserviceable one complete all as specified and as directed.
UNIVERSAL TRADING CENTRE
MS JYOTI INDUSTRIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .