Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAdmitted-Finance 2367 E BAWANA ROAD NARELA DELHI 40 | ₹1.9 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.1 Cr+₹25.4 L (13.6%)Admitted-Finance G II 3 ELDECO ESTATE ONE G T ROAD SECTOR 6 PANIPAT PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | ₹2.1 Cr+₹25.4 L (13.6%) | L2 | Admitted-Finance |
| 3 | L3₹2.2 Cr+₹30.9 L (16.5%)Admitted-Finance | ₹2.2 Cr+₹30.9 L (16.5%) | L3 | Admitted-Finance |
| 4 | L4₹2.2 Cr+₹35.8 L (19.1%)Admitted-Finance N A | NA | NA | 121004 | ₹2.2 Cr+₹35.8 L (19.1%) | L4 | Admitted-Finance |
| 5 | L5₹2.5 Cr+₹65.8 L (35.2%)Admitted-Finance | ₹2.5 Cr+₹65.8 L (35.2%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M.C.CONSTRUCTION CO. L6 | RAJENDER KUMAR GUPTA L7 | b p dabas and brothers L8 | SANJEEV ASSOCIATES L1 | m/s pupinder pal singh L3 | M/s Surender & Co. L2 | Surender Kishan Gupta & Co. L4 | Pankaj Builders L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Laying and Jointing PVC Pipe. Heading | |||||||||||
| 1.01 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C | 261 | Point | 1,080 ₹2,81,880 | 990 ₹2,58,390 | 1,050 ₹2,74,050 | 980 ₹2,55,780 | 700 ₹1,82,700 Lowest | 1,004 ₹2,62,044 | 990 ₹2,58,390 | 985 ₹2,57,085 |
| 1.02 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, 2 way modular switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cableetc. as required. | 4 | Point | 1,185 ₹4,740 | 1,050 ₹4,200 | 1,300 ₹5,200 | 940 ₹3,760 Lowest | 950 ₹3,800 | 1,102 ₹4,408 | 1,057 ₹4,228 | 1,057 ₹4,228 |
| 1.03 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | 360 | PM | 325 ₹1,17,000 | 200 ₹72,000 | 250 ₹90,000 | 190 ₹68,400 | 170 ₹61,200 Lowest | 302 ₹1,08,720 | 200 ₹72,000 | 240 ₹86,400 |
| 1.04 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | 240 | PM | 435 ₹1,04,400 | 219 ₹52,560 Lowest | 300 ₹72,000 | 300 ₹72,000 | 247 ₹59,280 | 405 ₹97,200 | 308 ₹73,920 | 300 ₹72,000 |
| 1.05 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 5/6 &15/16A modular switch, connections etc. as required. | 54 | Each | 450 ₹24,300 | 250 ₹13,500 Lowest | 510 ₹27,540 | 470 ₹25,380 | 435 ₹23,490 | 419 ₹22,626 | 495 ₹26,730 | 490 ₹26,460 |
| 1.06 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular
switch, connections etc. as required. | 25 | Each | 400 ₹10,000 | 230 ₹5,750 Lowest | 410 ₹10,250 | 370 ₹9,250 | 346 ₹8,650 | 372 ₹9,300 | 401 ₹10,025 | 390 ₹9,750 |
| 1.07 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. | 16 | Each | 1,200 ₹19,200 | 1,080 ₹17,280 | 1,250 ₹20,000 | 1,200 ₹19,200 | 1,060 ₹16,960 Lowest | 1,116 ₹17,856 | 1,232 ₹19,712 | 1,200 ₹19,200 |
| 1.08 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 235 | PM | 250 ₹58,750 | 167 ₹39,245 | 190 ₹44,650 | 160 ₹37,600 | 147 ₹34,545 Lowest | 233 ₹54,755 | 167 ₹39,245 | 180 ₹42,300 |
| 1.09 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire | 160 | PM | 345 ₹55,200 | 233 ₹37,280 | 290 ₹46,400 | 220 ₹35,200 | 207 ₹33,120 Lowest | 321 ₹51,360 | 233 ₹37,280 | 280 ₹44,800 |
Tender Value
₹3.4 Cr
EMD Value
₹5.7 L
Closing Date
28 Dec 2021, 3:00 pmClosed
EE (M)-I/Central Zone, Arjun Marg, Defence Colony,
EE (M)-I/Central Zone, Arjun Marg, Defence Colony, New Delhi-110024
Construction of Double Storey building at Lajpat Nagar Colony Hospital in Ward No. 57-S, Central Zone.
2021_SDMC_98821_1
D/EE (M)-I/CNZ 2021-2022/43-1
Open Tender
Civil Works
Percentage
150 days
Defence Colony
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,500
₹5.7 L
Yes
29 Dec 2021
18 Dec 2021
29 Dec 2021
18 Dec 2021
28 Dec 2021
18 Dec 2021
Amount
Laying and Jointing PVC Pipe. Heading
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, 2 way modular switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cableetc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 5/6 &15/16A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper conductor cable, in PVC sleeve of suitable size on the floor/ wall, or side of the table/door etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Supplying and fixing PVC batten/ angle holder including connections etc. as required.
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 4 way (4 + 12), Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 6 way (4 + 18), Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 8 way (4 + 24), Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way double door
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 Amps
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole.
Supplying and fixing following rating ,double pole,240 volt,isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required 63 amps
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 630 A,50KA,FPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 250 A,50KA,FPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 100 A,30KA,FPMCCB
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Up to 35 sqmm
Laying and fixing of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of following size on wall surface as required. Up to 35 sqmm
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existingRCC /HUME/METAL pipe as required. Above 185 sq. mm and upto 400 sq. mm
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
S/L of following size DWC HDPE Pipe ISI marked along with all accessories like socket ,bend ,couplers etc.conforming to IS 14930 ,part II complete with fitting and cutting ,jointing etc .direct in ground (75 cm below ground level )including excavation and refilling the trench but excluding sand cushioning and protective covering etc, complete as required (a) 200 mm dia (OD-200 mm & ID-175 mm nominal)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (a) 2 X 6 sq. mm (19mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (a) 4 X 25 sq. mm (28mm)
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
S/1/T/C of universal aluminium batten 4ft long Pre coated CRCA Sheet Steel, End caps suitable for TS and TS LED tubelights 10-20W etc as required.
Supply, Installation, Testing and Commissioning of 10 watts surface/wall mounted LED bulkhead factual impace dust and water resitant luminary with IP 65/66 protection
S/1/T/C of LED Tubelight lamp T-5/T-8 20 Watt rating made up of high efficient LEDs with the following specifications:(a) Total system wattage 20 watt +/- 5% (b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
S/1/T/C of Surface mounting CRCA housing 36W LED luminaire with acrylic cover diffuser with following specifications including fixing on existing wall/recess with connections as reqd. (a)Total system wattage=36 watt+/- 5% (b )Luminous efficacy >=95 lumens/watt. (c)Power factor >=0.95
Supply,installation,testing & commissioning of single phase monoblock pump set complete with all accessories workable on 240/415 volts,50 Hz AC supply.(a) 1 HP (0.75 KW) Single phase pump set,head from 12-30 mtr. suction and delivery 25X25 mm.
Supply of 2 x 6 Sqmm size of XLPE insulated and PVC sheathed Al. Conductor Armored cable confirming to 7098 as reqd.
Supply of 4 x 25 Sqmm size of XLPE insulated and PVC sheathed Al. Conductor Armored cable confirming to 7098 as reqd.
Supply of 9 watts LED retrofit lamp suitable for B-22 holder.
Supply of 12'' ( 300 mm )sweep 1400 RPM exhaust fan heavy duty complete with shutter,blade etc as required.
SITC of 60 W LED Flood light luminiare fitted with lens ,made of pressure die cast aluminium housing & toughened glass cover complete with following specification as required.(b) Total system wattage=60 watt+/-5%.(d) Luminiaire effiency >=100Lm/w.(e) power factor >=0.95.(f) Protection class -IP-66
P & F of Hot Press Sheet Moulded Compound (SMC),fire retardant (Temp. resistanceup to 200 deg.C),IP-55 weatherproof pole box of inner dimension 200 mmx160 mmx98 mm complete with suitable arrangement for fixing of 2 nos.of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN channelwith 2 nos.of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc. as required.
Supply and fixing of 4.5 KG DCP with CO2 gas cartridge fire extinguisher (conforming to IS:2171 with cylinder fully charged)
Bidder Name
Amount
M.C.CONSTRUCTION CO.(GSTN-07AJOPK0381M2ZS)
RAJENDER KUMAR GUPTA(GSTN-NA)
b p dabas and brothers(GSTN-NA)
SANJEEV ASSOCIATES(GSTN-NA)
m/s pupinder pal singh(GSTN-NA)
M/s Surender & Co.(GSTN-NA)
Surender Kishan Gupta & Co.(GSTN-NA)
Pankaj Builders(GSTN-NA)
Pankaj Builders
Surender Kishan Gupta & Co.
m/s pupinder pal singh
RAJENDER KUMAR GUPTA
M/s Surender & Co.
b p dabas and brothers
M.C.CONSTRUCTION CO.
M/s Surender & Co.
m/s pupinder pal singh
Surender Kishan Gupta & Co.
M.C.CONSTRUCTION CO.
Pankaj Builders
RAJENDER KUMAR GUPTA
b p dabas and brothers
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 20.34 MB
Tendernotice_2.pdf
PDF • 5.07 MB
Tendernotice_3.pdf
PDF • 0.79 MB
Tendernotice_4.pdf
PDF • 0.11 MB
BOQ_107608.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .