Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.4 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹15.9 L+₹6,775 (0.43%)Rejected-AOC 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹17.6 L+₹1.8 L (11.4%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹20.3 L+₹4.5 L (28.2%)Rejected-AOC | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹21.3 L+₹5.5 L (34.8%)Rejected-AOC | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
31 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NW) MANKHURD
GE (NW) MANKHURD, MUMBAI-400088
COMPREHENSIVE REPAIR/MAINTENANCE OF SECURITY LIGHTS, GARDEN LIGHTS AND ALLIED WORKS AT TS MAHUL AND SEWRI UNDER (NW) MANKHURD
2021_MES_428219_1
8065/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (NW) MANKHURD
AS PER TENDER DOCUMENTS AND NIT
9 documents required · 9 mandatory
₹500
GE (NW) MANKHURD
₹48,000
Yes
6 Apr 2021
5 Mar 2021
2 Apr 2021
5 Mar 2021
31 Mar 2021
19 Mar 2021
5 Mar 2021 - 18 Mar 2021
60 days
Amount
Notes : (i)The contractor should be in possession of valid electrical license to execute electrical works. (ii) Supervisor for execution of electrical works/ electrical component of works employed by the contractor shall possesses supervisor certificate of competency issued by concerned State Government/ Union Territory and the worker/ tradesmen for execution of electrical works/ electrical component of works shall hold necessary permit issued by concerned State Government/ Union Territory. Excavation in trenches not exc. 1.5 mtr wide and not exc.1.50 mtr depth for foundation etc or for shafts, wells, cesspits, manholes etc n.exc 10 Sqm on plan & n.exc 1.5 mtr in depth for laying of underground cable, erection of poles etc. and getting out in soft/loose soil including separating serviceable cable protection cover for re-use at site obtained during excavation complete all as specified and directed.
All as per ser item No 01 above but depth exc 1.5 m upto 3.0 m complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick as in soil complete all as specified and directed.
Removal of surplus soil not exc 50mtr distance and depositing where directed at a level n.exc 1.5 mtr above starting point complete all as specified and directed.
M&L for sand cushioning by spreading in trenches fine dry river sand by gently punning down manually as in cable protection complete all as specified and directed. Note : Sand after punning down will be measured
Supply and laying precast concrete cable cover class LV ISI Marked, type-I, flat size 250mm x 150mm x 40mm laid in trenches complete all as specified and directed.
Laying only un-reinforced precast concrete cable cover class LV, type-I, flate size 250mm x 150mm x 40mm laid cable cover obtained vide Ser Item No 9.00 to 13.00 shall be reused complete all as specified and directed.
M&L for cutting existing road/hard standing not exc 45 cm x45 cm in wide & depth getting out excavated material for laying GI tube ;returning filling & well ramming watering finish surface 10 cm from top using PCC 1:3:6; including removal of surplus soil complete all as specified and directed.
Taking out old unserviceable underground cable XLPE insulated, PVC sheathed armoured heavy duty aluminum conductor LT 1100 Volts grade of size 4 Core 10 Sqmm, fixed on pole, wall and laid in trenches etc after disconnecting complete all as specified and directed. Note - Excavation and earth work will be mesured and paid separately.
All as per item No 9.00 but of size 4 core 16 Sqmm
All as per item No 9.00 but of size3.5 core 25 Sqmm
All as per item No 9.00 but of size 3.5 core 95 Sqmm
All as per item No 9.00 but of size 3.5 core 240 Sqmm
Supply and lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size:- 10 Sqmm x 4 core.
All as per item No 14.00 but of size 4 core 16 Sqmm
All as per item No 14.00 but of size 3.5 core 25 Sqmm
All as per item no 14.00 but of size 3.5 core 95 Sqmm
All as per item no 14.00 but of size 3.5 core 240 Sqmm
M&L for straight through joint (epoxy) suitable for 3 ½ / 4 core up to 95 Sqmm size underground cable complete all as specified and directed.
M&L for straight through joint (epoxy) suitable for 3 ½ /4 core 95 to 240 Sqmm size underground cable complete all as specified and directed.
M&L for preparation of old painted surfaces of pre-stressed concrete pole upto 11/9 mtr long by scarping old paint and applying two coats of cement base paint including numbering of pole with black oil paint painting the base of the pole in alternate black and yellow stripes each 30 Cm apart up to 1.5mtr height including marking of MES No with black paint on the pole complete all as specified and directed.
M&L for preparation of old painted surfaces of Steel Tubular pole upto 9 mtr long by scarping old paint and applying two coats of Aluminium paint including numbering of pole with black oil paint and painting the base of the pole in alternate black and yellow stripes each 30 Cm apart up to 1.5mtr height including marking of MES No with black paint on the pole all complete all as specified and directed.
S& F in replacement of GI steel tubing medium grade 40mm dia and length up to 1.5 meter bent to shape of offset angle upto 45degree for fixing of security /street light fittings including MS clamps made of 32mm x 5mm flat iron, nuts , bolts, etc complete all as specified and directed.
M&L for cutting existing road/hard standing not exc 45x45 cm in wide & depth getting out excavated material for laying GI tube ;returning filling & well ramming watering finish surface 10 cm from top using PCC 1:3:6; including removal of surplus soil complete all as specified and directed.
S&F of HDPE pipe 50 mm dia, PN-10 for laying in ground, road crossing etc for cable protection including necessary fittings, clamps for supports, etc complete all as specified and directed.
Supply and fix in replacement of FRP looping box of size 155x210x92 mm with connector, MCB 6 Amps, Din Rail, GI clamps made out of GI flat of size 25mm X 3 mm channel including making connections complete all as specified and directed. Make - Confirm to Cat No KF 1616 G of Hensel/ National / Sintex .
M&L for taking down old unsv and supply & lay 3 Core 1.5 Sq mm size multistranded copper conductor PVC unsheathed 650 / 1100 Volt Grade As per IS 694 with and including 20 mm dia PVC conduit and passing through PVC conduit with necessary saddle, clamps, bolts & nuts, all for interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc complete all as specified and directed.
M&L for Multistranded Copper Conductor cable of 3 Core 1.5 Sq mm size drawn through steel tubular poles for interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc taking down old unsv cable complete all as specified and directed.
M&L in repair MCCBs 3 Pole 250 Amps,36 KA including connecting up electrically with proper lugs glands etc complete all as specified and directed.
M&L in repair MCCBs 3 Pole 200 Amps,36 KA including connecting up electrically with proper lugs glands etc complete all as specified and directed.
M&L in repair MCCBs 3 Pole 100 Amps,16 KA including connecting up electrically with proper lugs glands etc complete all as specified and directed.
Supply and fix 3 pole power contactor 32 A , coil voltage 230 V complete all as specified and directed.
M&L in repairs for 24 Hrs 240 V FM1 Quartz type daily timer switch for controlling street lights contactors complete all as specified and directed.
Dismentling of PCC foundation / coping from pole not exc 1.65 below ground level for removing of pole complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregates as in pedestal of pole/ strut and in copping including necessary form work and finishing exposed faces of concrete even and smooth using extra cement complete all as specified and directed.
Supply and fix in replacement 8 Watt LED Bollard garden light fitting with efficient high output COB LED, pressue die cast powder coated housing with PC diffuser driver nut bolt ,washer base plate foundation 0.3mtrx0.3 mtr x.0.3 mtr by PCC 1:2:4 type B-1 using 20mm graded stone aggregates of size including excavation and earth work , provision of GI bend of size 50MM dia in the PCC for cable entry the fitting shall conform to cat No-CONEBL8WLED857SSYMTOPC of Havells equivalent from Philips/ Bajaj/CG complete all as specified and directed.
Suply and fix New generation, post-top LED light 15W,energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LEDs as light provision of GI bend of size 50MM dia in the PCC for cable entry the fitting with nut bolts,washer shall conform to cat No-RUBYMINIPT 15WLED830 PSYMT OPC of Havells equivalent from Philips, bajaj/CG complete all as specified and directed.
S & F in replacement of security light fitting/Building security light LED type 60 watts with Pressure die cast aluminium housing with hight power LED as lighting source and lens embedded PC cover having TOP OPENING seerated driver compartment with IP 66 protection and impact resistance of IK07 with 10KV built-in surge protection device etc all as directed by Engineer in charge Cat no -ENDURAPEARLNEOSL60WLED757SASYTOPC OF HAVELLS or equivalent Bajaj/Philips/CG complete all as specified and directed.
S&F in Repairs 40 W LED recessed full lite luminaire with glare free uniform illumination with longer life and less maintainance 2x2 fitting mounted direct/indirect architectural luminaire including connecting 1.5 Sqmm white colour suitable for false ceiling fixing arrangement all as specified and directed. Make : Bajaj/Philips/Crompton/Havells
Supply, install and testing, commissioning feeder piller box outdoor type, IP-54 protection CPRI approved, factory fabricated, cubical panel wall mounted, self supported, free standing type, made out of 3.00 mm thick CRCA sheet with locking arragement, suitable for 3 phase, 4 wire, 415 volt, 50HZ, AC supply including suitable size copper conductor control wiring and powder coating with connecting the cables with necessary cable glands, lugs etc proper arrangement for veritilation complete with and including the following accessories :- Location: NSD Sewri (i) Copper bus bar Phases & Neutral for 200 Amps- 01 set (a) MCCB 4 pole 25 KA 100A - 1 Nos Note - The lay out drawing of the panel shall be got approved by the contractor before panel fabrication from GE and shall be fabricated from CPRI approved manufacturer as per approved make of CA.
M&L for earthing using GI earthing strip 32 x 6mm complete with galvanised steel earth plate electode 600mmx600mmx6mm thick buried directly in ground, earth pit not less than 2.25 meters deep below ground level connection to and including GI strip of size 32x6mm to the extend 7.5 mtr as earth lead by means of GI bolts, Nuts etc. with provision of charcoal and salt all as per electrical plate No 3 of SSR Part I including water arrangement with GI Pipe 20 MM dia (medium Grade), earth lead protection pipe 50mm medium grade with bends, elbow etc. from earth plate to test point, excavation and earth work returning, filling, ramming and removing of soil to distance not exc 50mtr, make good to match with existing surface making PCC pit (Earth chamber) having internal size 30cm x 30cm x 30cm and outer size 60cm x 60cm x 60cm with RCC reinforced cover 50mm thick with one lifting handle made of 8mm dia MS bar funnel wie mesh and testing on completion including making test point on wall as per SSR specification all as specified and directed.
Comprehensive AMC of 60 KVA UPS 3 phase, including servicing / replacement of worn out parts like PCB, IGBT based, Diode, Capacitors,relay,cooling fan,indicators,connectors,lugs,wires,switches,fuses and to attending all breakdown calls and check all electronic component/cards,checking of rectifier/inverter logic boards,adjust battery charging current,cheking of auto transfer facility between inverter and bypass & bypass to UPS, verification/setting/rectification of LCD mimics alarms, indications, UPS & battery changover test. Location: RUKMANI Bldg Mahul
Comprehensive AMC of 30 KVA 3 phase,415 V Servo voltage stabilizer (6 Nos) including replacing of all components releted with AVR following:- (a) I.C. Electronic control card (b) Control Transformer (c) R.C. Network (d) Main big gear (e) Toggle switch (f) Indication Lamp (g) Voltmeter (h) A.C. synchronous Motor (j) Dimmer stopper all as specified and directed by Engineer –in –Charge. Note: (i) The rate quoted shall be inclusive transportation,material and labour,including all defective spare make as per existing,complete. (ii) Attending of fault within 8 hours of intimation to avoid distruption of receive to user technical requirement.Delay of attending of fault by more than 01 day would invite penalty charge of 1000/hr.
Supply and fix in repairs Power Capacitors of Rating 100 KVAR 415 Volt Naturally air cooled Double dielectric heavy duty, MPP type 440 Volt 50 HZ Watt Less Power Capacitors wattage not more than 0.5 Watt per KVAR with meter system conforming to IS 13340 and 13341 ISI Marked complete all as specified and directed.
All as per item No 48.00 above but Power Capacitors of Rating 50 KVAR 415 Volt complete all as specified and directed.
All as per item No 48.00 above but Power Capacitors of Rating 25 KVAR 415 Volt complete all as specified and directed.
All as per item No 48.00 above but Power Capacitors of Rating 10 KVAR 415 Volt complete all as specified and directed.
All as per item No 48.00 above but Power Capacitors of Rating 5 KVAR 415 Volt complete all as specified and directed.
M&L for Cleaning of 90800 ltrs capacity underground/semi underground sump/well by draining out sludge from bottom, by blocking all inlet/outlet, removing alge-fungi growth from wall, floor, ceiling by wire brush/ water jet pressure machine, cleaning complete surface and dis-infecting with bleaching powder and marking cleaning date and due date etc complete all as specified and directed.
M&L for Cleaning of 68100 ltrs capacity underground/semi underground sump/well by draining out sludge from bottom, by blocking all inlet/outlet, removing alge-fungi growth from wall, floor, ceiling by wire brush/ water jet pressure machine, cleaning complete surface and dis-infecting with bleaching powder and marking cleaning date and due date etc complete all as specified and directed. Note : A sum of Rs 39,372.00 towards sch of credit shall be deducated to arrive the contract sum.
sapana enterprises
M/s R J TRADING CO
Radha Engineering Services
M/s Bhagirathi Electricals
Chaudhary Enterprises
DHARMESH ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .