Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical 00 NEAR BANSI LAL KOTHI HANSI ROAD BHIWANI HARYANA 127021 | BHIWANI | BHIWANI | HARYANA | 127021 | - | Rejected-Technical Not Eligible |
Tender Value
₹64.0 L
EMD Value
₹1.3 L
Closing Date
2 Apr 2025, 5:00 pmClosed
PRAMESH Kumar
ED - Hisar
Construction of 200 Bedded Hospital in Sector-9 at Fatehabad (Pdg. 500 LPH RO Plant, Water Coolers and other accessories) RECALL
2025_HRY_436765_1
20256E323B5C 4695 4BD8 A605 8F49B15F4832666BAR
Open Tender
Electrical Works
Works
150 days
Fatehabad
2 documents required · 2 mandatory
₹5,000
₹1.3 L
Yes
28 Jul 2025
27 Mar 2025
3 Apr 2025
27 Mar 2025
2 Apr 2025
27 Mar 2025
Amount
[22.103.3]Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 3. 25 mm nominal bore [Through Rate]
[22.86.3]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes [Through Rate]
S.I.T.C of R.O. plant 500 LPH with TFC membrane Make Eureka Forbes, Ion Exchange ,Suez (Exclusive GST). Specification: Reverse Osmosis System having capacity of RO 500LPH designed for Treatment of saline water in the TDS range of 500-2000ppm which are Completely assembled /Pre-piped/Pre-wired with Microprocessor-based control Pannel for ease of operation and inbuilt process Logic having provision for Auto start/stop based on Water level in the Tank with MCB for Plant operation and Raw water pump integrated with Plant. Integrated pretreatment Module for removal of suspended solids along with pressure gauges, Robust high Pressure Pump in SS 304 Construction, Inbuilt Protection to high Pressure Pump by Way of Low Pressure Switch/high Pressure switch and Glycerine filled SS Pressure gauges for durability, On line Rota meter for measuring permeate flow and Powder coated MS skid with plated hardware having ISO 9001 and Indian Medical Association Certification with Following Technical specification with 30% Recovery of Pure water from Raw Water.TECHNICAL SPECIFICATION System Specification 1 Raw Water Feed Pump Type : Centrifugal Horizontal Quantity : 1 No Capacity : 1.2m3/hr @ 25 mwc. MOC : CI. Make : KBL/Crompton 2 Pressure Sand Filter (PSF) Quantity : 1 No. Capacity : 1.2 m3/hr MOC of Vessel : Polyglass Media : Anthracite plus Support Bed. Make of Vessel : Pentair/Aventura /Wave Type of valve : Manual – Multiport valve 3 Activated Carbon Filter (ACF) Quantity : 1 No. Capacity : 1.2 m3/hr . MOC of Vessel : Polyglass Make of Vessel : Pentair/Aventura /Wave Media : Activated Carbon plus Support Bed. Type of valve : Single Multiport4 Antiscalant Dosing System Dosing Pump Quantity : 1 No. Type : Electro-magnetic. Capacity : 1.5LPH Discharge Pressure : 2.5 kg/cm sq Make : E Dose Dosing Tank 1 Nos. Capacity : 50 lit. Make : Sintex/Equivalent Material of Construction : HDPE. 5 Micron Cartridge Filter (MCF) Quantity : 1 No. Capacity : 1.2 m3/hr MOC of Housing : ABS MOC of Cartridge : PP. Filter Rating : 5 micron Make :Pratham/ Equivalent Size : 20’’long 6 High Pressure Pump Quantity : 1 No. Capacity : 1.2 m3/hr Maximum Discharge Pressure : 14.0 kg/cm2. Material of Construction : SS 304- Three Phase Make : Nanfang/ CNP 7 Reverse Osmosis System Quantity : 1 No. Permeate capacity : 400-500 LPH. Membrane Type : Spiral wound Membrane Specification : TFC-polyamide Make of Membrane : Suez/LG/ Equivalent Size : Dia. 4’’ X 40’’ long No. of Membranes : 2 Nos. No. of Membrane Housing : 2 Nos. Skid Material of Construction: MSEP Piping MOC: UPVC/CPVC 8 Control Panel+C8 Quantity : 1 No Cabling (Scope As per Termination ) : 1 Lot. 9 UV System Quantity : 1 NO Make : Sukrut/Equivalent 10 Instruments Pressure Gauges : 3 Nos Pressure switches : 2 Nos. Conductivity meter : 1No. Rate of flow indicators : 2No. For RWP : RO Permeate Level switch : 2 Nos.
Supply of Antiscalent chemical for dosing. Make : Eureka Forbes /ION Exchange/I-Treat Exclusive GST
Supply of Sediment filter. Make : Eureka Forbes /ION Exchange/I-Treat Exclusive GST
Supply of copper wire 4mm (4 core) Make Polycab, Grandly/Havells Exclusive GST
Providing and fixing of shed for R.O. plant. Plant. Shed made with square pipe of 40 mm*40mm and blue profile sheet size 0.45 mm ,shed size length -2100mm ,width-2100mm,height-2250 mm including all necessary hardware ,primer coating ,synthetic enamel paint ,hanger, clamp and other accessories. Exclusive GST
Lifting/placing of R.O Plant units to higher floor/terrace Exclusive GST
Supply of 80 Litre Water Cooler with full Stainless Steel with UV Protection Make :Eureka Forbes ,Ion Exchange ,Usha International. Exclusive GST. Specification : Water cooler with multiple functions of cooling and purifying the water providing dual benefits of convenience and safe health. The cooler should havedual faucets, one providing cold purified water and the other providing normal Purified water. Last point UV purification process would ensure that water is 100 % safe for drinking with zero waste and Electronic Eye Protections ensuring contamination free water every time. The product should have been manufactured at green environment and complies with ISO 9001 for ensuring consistent and long lasting defect free supplies as well Quality. (Ideal for TDS ranging between 1-200 PPM).
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .