Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹5.7 LAccepted-AOC | L-1 | Accepted-AOC BEING LOWEST AND REASONABLE |
Tender Value
₹6 L
EMD Value
₹12,000
Closing Date
29 Aug 2023, 6:00 pmClosed
GE Umroi
Military Engineer Services Garrison Engineer Umroi Umroi Military Station PO - Barapani, Shillong-793 103
REPAIRS TO SUMMER COOLING APPLIANCES, SOLAR WATER HEATERS INCL CONNECTED WORKS AT UMROI MIL STATION UNDER GE UMROI
2023_MES_594730_3
8734/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Umroi
As per NIT
8 documents required · 8 mandatory
₹500
GE Umroi
₹12,000
19 Jan 2024
3 Aug 2023
30 Aug 2023
3 Aug 2023
29 Aug 2023
10 Aug 2023
Amount
Repair and maintenece of refrigerator capacities 230 ltr to 310 ltrs of existing make, carrying out the inspection carefully of the all units of refrigerator thouroghly, trace out the faults, and the repair the same in original position or MES yard/ work whop etc. by diconnecting and dismantling the defective units, gas filling, remove the gas leakage replacement of unserviceable spare parts, existing serviceable parts by cleaning etc. and reconnecting, reassembling the same after repair complete all as specified and directed by Engr-in-Charge. Note : (i) The Spares parts and jointing material required for the repair after opening the refrigerator shall be done in the presence of JE/ Engr-incharge and the same will measured and paid seperately. as supply only under relevent item 3 to 15 of BOQ. (ii) The fixing of existing serviceable parts shall be included in quoted rates. without claiming any extra cost. (iii) All the T&P items, transportation, welding stick, capilllary tubes NRV etc. shall be arrange by the contractor without claiming any extra cost.
Material and labour for Gas filling R134a charging with nytrogen testing by charging hose matching with existing size and make of refrigerator, complete all as specified and as directed
Supply only Freezer chamber matching with existing size and make of refrigerator, complete all as specified and as directed
Supply only Cool condenser matching with existing size and make of refrigerator, complete all as specified and as directed
Supply only Fan motor, with Fan blade matching with existing size and make of refrigerator, complete all as specified and as directed
Supply only Heater for defrosting purposes, matching with existing size and make of refrigerator, complete all as specified and as directed
Supply only FF timer, matching with existing size and make of refrigerator, complete all as specified and as directed
Supply only Biometal, fuse matching with existing size and make of refrigerator, complete all as specified and as directed
Supply only PCB timer matching with existing size and make of refrigerator, complete all as specified and as directed
Supply only Relay set, PCTR, matching with existing size and make of refrigerator, complete all as specified and as directed
Supply only Capacitor 3.5, 5 or 6 MFD matching with existing size and make of refrigerator, complete all as specified and as directed
Supply only Door switch matching with existing size and make of refrigerator, complete all as specified and as directed
Supply only Fridge light and light holder matching with existing size and make of refrigerator, complete all as specified and as directed
Supply only Drier strainer suitable for matching with existing refrigerators, complete all as specified and as directed
Supply only Thermostat matching with existing size and make of refrigerator, complete all as specified and as directed
Repair and maintenece of Deep Freezers of capacity 280/310/320 lts existing make, carrying out the inspection carefully of the all units of deep freezers thouroghly, trace out the faults, and the repair the same in original position or MES yard/ work whop etc. by diconnecting and dismantling the defective units, gas filling, replacement of new spare parts, existing serviceable parts etc. and reconnecting, reassembling the same after repair complete all as directed by Engr-in-Charge. Note: (i) The Spares parts required for the repair after opening the deep freezer shall be carried out in the presence of JE /Engr-incharge and the same will measured and paid seperately as supply only under relevent item No 18 to 26 of BOQ. (ii) The fixing of existing serviceable parts shall be included in quoted rates. without claiming any extra cost. (iii) All the T&P items, transportation, capillary tube, welding stick, antichoking NRV jointing material etc. shall be arrange by the contractor without claiming any extra cost.
Material and labour for Gas filling R134a charging with nytrogen testing by charging hose suitable for matching with existing size and make of refrigerator, complete all as specified and as directed
Supply only Fan motor, with Fan blade 220-240 volt, 0.10 amp suitable for matching with existing size and make of deep freezer, complete all as specified and as directed
Supply only Heater for defrosting purposes, suitable for matching with existing size and make of deep freezers, complete all as specified and as directed
Supply only FF timer, suitable for matching with existing size and make of deep freezers, complete all as specified and as directed
Supply only PCB timer suitable for matching with existing size and make of deep freezers, complete all as specified and as directed
Supply only Compressor hermetically sealed suitable for matching with existing size and make of deep freezers, complete all as specified and as directed
Supply only Capacitor 3.5, 5 or 6 MFD suitable, matching with existing size and make of deep freezers complete all as directed.
Supply only Relay set, PCTR, matching with existing size and make of deep freezers, complete all as specified and as directed
Supply only Drier strainer suitable for matching with existing deep freezers, complete all as specified and as directed
Supply only Thermostat suitable for matching with existing size and make of deep freezers, complete all as specified and as directed
Repair and servicing of Split/Window air conditioners of capacities 1.5TR to 2.0TR existing make, carefully carrying out the inspection of the all units of Air conditioners check thouroghly, trace out the faults, and the repair the same in original position or MES yard/civil work whop etc. by diconnecting and dismantling the defective units, gas filling, Replace of filters, replacement of unserviceable spare parts, existing serviceable parts etc. including reconnecting, reassembling the same after repair including testing complete all as directed by Engr-in-Charge. Note: (i) The Spares parts required for the repair after opening the air conditioners shall be carried out in the presence of JE/Engr-incharge and the same will measured and paid seperately as supply only under relevent item No 26 to 45 of BOQ. (ii) The fixing of existing serviceable parts deemed to be included in quoted rates without claiming any extra cost. (iii) All the T&P items, fly nuts,flux welding stick, transportation, jointing materials etc.shall be arrange by the contractor without claiming any extra cost.
Material and labour for Gas filling for refrigerant (Gas R410A/R22) Gas charging with nytrogen testing by charging hose matching with existing size and make of existing airconditioners, complete all as specified and as directed
Supply only cooling condenser suitable for matching with existing 1.5/2.0TR capacity of airconditioners, complete all as specified and as directed
Supply only Main board suitable for matching with existing airconditioners, complete all as specified and as directed
Supply only Display unit suitable for matching with existing airconditioners, complete all as specified and as directed
Supply only pvc drain water pipe suitable slush out condesate water for matching with existing air conditioners, complete all as specified and as directed
Supply only Air Filters suitable for matching with existing airconditioners, complete all as specified and as directed
Supply only Copper tube suitable for matching with existing airconditioners, complete all as specified and as directed
Supply only Copper capillary suitable for matching with existing airconditioners, complete all as specified and as directed
Supply only insulation suitable for Copper tube /capillary matching with existing airconditioners, complete all as specified and as directed
Supply only Single phase asynchronous PSC Fan motor suitable matching with existing airconditioners complete all as directed.
Supply only capacitor suitable matching with existing motor of air conditioners, complete all as specified and as directed
Supply only Heat condenser coil suitable matching with existing of airconditioners, complete all as specified and as directed
Supply only Gas valves suitable matching with existing of airconditioners, complete all as specified and as directed
Supply only Compressor hermetically sealed suitable matching with existing of air conditioners, complete all as specified and as directed
Supply only Power relay Single Phase Contactors suitable matching with existing of air conditioners, complete all as specified and as directed
Supply only Drier strainer suitable for matching with existing airconditioners, complete all as specified and as directed
Supply only Capacitor 36+2.5 MFD aluminium casing/aluminium terminals (quadraple fast on) 440volts suitable matching with existing compressor of air conditioners, complete all as specified and as directed
Supply only Capacitor 50+4 MFD aluminium casing/aluminium terminals (quadraple fast on) 440volts suitable matching with existing comressor of air conditioners, complete all as specified and as directed
Repair and servicing of Solar water heaters of capacities 200 LPD to 300LPD any make, carrying out the inspection of the all units of solar water heaters thouroghly, trace out the faults, and the repair the same in original position or work whop etc. by diconnecting and dismantling the defective units, cleaning of all glass, checking solar insolation, direction of rays, cleaning the makeup water tank inlet and outlet connections, membrane etc. replacement of new spare parts,/old serviceable parts etc. as required at site and reconnecting, reassembling the same after repair including testing complete all as directed by Engr-in-Charge. Note: (i) The Spares parts and jointing material, PCC work etc. required for the repair after opening the solar water heaters shalll be carried out in the presence of JE/Engr-incharge and the same will measured and paid seperately as supply only under relevent item of BOQ. (ii) The fixing of existing serviceable parts shall be included in quoted rates. without claiming any extra cost. (iii) All the T&P items, transportation shall be arrange by the contractor without claiming any extra cost. (iv) The cost of all new fittings PPR/GI Flange Nipple, dead Flange, EPDM Rubber flange Gasket, Flexiable hose pipe, collector nut Bolt Required clamp/Washer shall be arrange by the contractor be included in quoted rates without any claiming any extra charges.
Supply and fix of Insulation material with suitable Clamps and screw for GI/PPR pipe lines of Solar water heating System of existing size, complete all as specified and as directed
M&L for cement concrete 1:2:4 type B1 (using 20mm graded aggregate) for coping the solar water heaters, complete all as specified and as directed
Welding in repairs exceeding 2.5cm and not exceeding 5 cm in length and Thickness of Metal to be welded n exc. 6mm thickness complete all as specified and directed Note : (i) All T&P and welding machines, jointing materials shall be included in quoted rates. (ii) The necessary electricity shall be paid by the contractor on reading of energy meter and tapping shall be provided from Main LT panel only and the cable shall be arrange by contractor without claiming any extra charge.
Supply and fix in repair heating element 3.0 KW matching with existing ISI marked, complete all as specified and as directed
Supply & Fix in repair of rotational moulded polyethylene 1000 ltrs capacity water storage tanks, three layered, (ISI marked) (cylindrical vertical with closed top) hoisted and fixed in position in SSR Part-I including ball valves 20mm dia high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball including 20mm dia GI medium grade over flow pipe, approx lenght 1.5 mtr, 25 mm dia wash out pipe with pluged at one end complete all as specified and directed.
M&L for freparation of old painted steel or iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint over steel surface, height upto 6 meter, complete all as specified and directed.
Schedule of Credit
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .