Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC FLAT NO 201 LAXMI PARK NIWAS BT KAWADE ROAD GHORPADI PUNE 411036 | PUNE | MAHARASHTRA | 411036 | L1 | Accepted-AOC AOC | |
| 2 | L2₹25.0 L+₹3.3 L (15.0%)Rejected-Finance | L2 | Rejected-Finance Not being lowest tender | |
| 3 | L3₹30.1 L+₹8.4 L (38.7%)Rejected-Finance | L3 | Rejected-Finance Not being lowest tender | |
| 4 | L4₹31.4 L+₹9.6 L (44.4%)Rejected-Finance | L4 | Rejected-Finance Not being lowest tender | |
| 5 | L5₹31.7 L+₹9.9 L (45.7%)Rejected-Finance 197 CP COLONY MORAR GWALIOR 474006 MP | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | L5 | Rejected-Finance Not being lowest tender |
Tender Value
₹23.3 L
EMD Value
₹46,600
Closing Date
5 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF TA GWALIOR
GE AF TA GWALIOR-20
REPAIR/MAINT OF WINDOW ACs, SPLIT ACs , DEHUMIDIFIER AND CONNECTED WORKS IN WEST WING OF TECH AREA AT AF STN GWALIOR
2021_MES_421605_1
8900/1299/GWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE AF TA GWALIOR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF TA GWALIOR
₹46,600
Yes
9 Apr 2021
12 Feb 2021
8 Mar 2021
12 Feb 2021
5 Mar 2021
26 Feb 2021
60 days
Amount
Servicing of split AC of any type/size/make /model & capacity up to 3TR in any position/ work shop as convenient indoor & out door unit by cleaning of dust from condenser,air filter, cooling coils, by pressure pump of liquid line filter/capallary tube /expension valve, refrigerent inlet /out let pipe by Nitrogen and Etheline tri chloride(ETC),and checking of all electrical components and compressor etc. Quoted rate shall include replacement of minor part such as nut, bolts, screws, washers, brazing, lugs etc and testing for proper cooling all as directed. Note:-(i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’/BOQ and fixing charges for new items are deemed to be included under this item. (ii) Gas for charging of gas, if required, shall be issued free for filling under Schedule 'B'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item (iii) Contractor shall be paid only one time the labour charges quoted above in Schedule `A' items for a particular AC's repaired irrespective of the number of times labour and resources arranged by him to check the serviceability of the ACs and replacement of unserviceable / defective parts in order to maintain the ACs in serviceable/working condition. (iv) After opening of AC for servicing, an inventory shall be prepared for the unserviceable parts in front of AGE/JE and shall be signed by Contractor, Engineer-in-Charge/JE. (v) Contractor is required to take users' signature after repair and satisfactory installation of AC.
Servicing of Window type AC of any type/size/make /model & capacity at any position including cleaning & washing condenser assembly by chemical such as suction air filter & coil, brazing the discharge and suction line by and checking & retightening of all electrical connections. Quoted rate shall include replacement of minor part such as nut, bolts, screws, washers incl replacment of unserviceable parts of capacity 1.5/2.0 TR of single phase etc and testing complete all as specified and directed. NOTE :- (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. (ii) Gas for charging of gas, if required, shall be issued free for filling under Schedule 'B'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item (iii) Contractor shall be paid only one time the labour charges quoted above in Schedule `A' items for a particular AC's repaired irrespective of the number of times labour and resources arranged by him to check the serviceability of the ACs and replacement of unserviceable / defective parts in order to maintain the ACs in serviceable/working condition. (iv) After opening of AC for servicing, an inventory shall be prepared for the unserviceable parts in front of AGE/JE and shall be signed by Contractor, Engineer-in-Charge/JE. (v) Contractor is required to take users' signature after repair and satisfactory installation of AC.
Supply only the following items of Air conditioning split/window type AC of capacity 1.5/2/3TR of any make/model.
(a) Starting capacitor 80 mfd suitable for 240 Volts 50 HZ AC supply.
(b) Starting capacitor 100/120 mfd suitable for 240 volts 50 HZ AC supply
(c ) Running capacitor of 36 mfd +5/6 mfd suitable for 440 volts 50 HZ AC supply
(d) Running capacitor of 45/50/60 + 5/6 mfd suitable for 440 volts 50 HZ AC Supply
(e) Running capcitor of 10 mfd suitable for 430 volts 50 HZ AC supply
(f) PVC braded drain pipe of size 15 mm dia
(g) PVC braded drain pipe of size 20 mm dia
(h) PVC braded drain pipe of size 30 mm dia
(j) Blower motor 1330 RPM, 32W, Single phase suitable for 230 volts of 1.5 TR split AC Make : Guangdong welling Motor Model No. RP35 B-3 or equivalent as approved.
(k) Blower motor three speed 1/7HP to 1/5 HP 900 RPM suitable for 230 volts of 3.0 TR split AC Make : Speed King or equivalent as approved.
(l) Copper tubing of special annealed pressure copper of size 3/8" bore
(m) Copper tubing of special annealed pressure copper of size 5/8" bore
(n) Copper tubing of special annealed pressure copper of size 1/4" bore
(o) Copper tubing of special annealed pressure copper of size 1/2" bore
(p) Over load Relay confirming to Model 85001-2/3/4/5 Make :Annapurna
(q) Harmetic sealed Reciprocating compressor suitable for 1.5 TR 230 volts Make : Techamsha model No. 5522E
(r) Harmetic sealed Reciprocating compressor suitable for 1.5 TR 230 volts Make : Emersion CR22 MK-6
(s) Harmetic sealed Reciprocating compressor suitable for 2.0 TR 230 volts Make :- Emersion model No. CR-30
(t) Harmetic sealed Reciprocating compressor suitable for 3.0 TR 415 volts Make :- Emersion model No. CR-42
(u) Rotary compressor suitable for 1.5 TR 230 volts 50 HZ Make :- Techamsha model No. PH 290
(v) Rotary compressor suitable for 2.0 TR Make :- Techamsha model No. PH 380 or equivalent as approved
(w) Electronic sensing unit (PCB) with hand set suitable for PCB and display unit suitable for Split AC/Window AC 1.5/2.0 TR of any capacity, model and make
(x) Electronic sensing unit (PCB) with hand set suitable for PCB and display unit suitable for Split AC 1.5 TR of Make : LG complete all as specified and directed Make :- LG Model No. 1842
(y) Electronic sensing unit (PCB) with hand set suitable for PCB and display unit suitable for Split AC 2.0 TR of Make : LG complete all as specified and directed Make :- LG Model No. 1846
(z) Electronic sensing unit (PCB) with hand set suitable for PCB and display unit suitable for Split AC 3.0 TR (2x1.5) of any capacity, model and make
(aa) Electric fan motor 1/8 HP 900 RPM suitable for 3 TR split AC out door unit, three phase Make :- LG/Blue star/ Voltas or as per existing make of AC at site
(ab) Electric fan motor 1/10 or 1/12 HP 900 RPM, 60 Watt suitable for 1.5/2 TR split AC out door unit, single phase, Make:- LG/Bluestar/Voltas or as per existing make of AC at site.
(ac) Electric fan motor 1/10 or 1/12 HP 1400 RPM, 60 Watt suitable for 1.5/2 TR split AC out door unit, single phase, Make:- LG/Bluestar/Voltas or as per existing make of AC at site.
(ad) Electric fan motor 1/8 HP 1400 RPM suitable for 1.5/2 TR split AC out door unit, single phase, Make:- LG/Bluestar/Voltas or as per existing make of AC at site.
(ae) Blade set of fan motor of out door unit, made out of Aluminium sheet Suitable for shaft bore dia 1/2" and fan dia 16"/ 18" in existing air conditioner split type
(af) Blade set of fan motor of out door unit, made out of PVC Suitable for shaft bore dia 1/2" and fan dia 16"/ 18" in existing air conditioner split type
(ag) Evaporator complete indoor unit body made of PVC with GI base plate suitable for 1.5TR/2TR split AC complete all as specified and directed. Make :- LG/Blue Star/Voltas/Totaline/Carrier
(ah) Evaporator complete indoor unit body made of PVC with GI base plate suitable for 3 TR split AC complete all as specified and directed . Make :- LG/Blue Star/Voltas/Totaline/Carrier
(aj) Power contactor of rating 11 amps four pole suitable for 415 volts 1.5/2.0 TR split type AC having standard coil voltage of 220 volts in existing air conditioner, split type Make L&T type MNX-12
(ak) Power contactor of rating AC-3, 40 amps three pole suitable for 415 volts with auxillary contacts 02NO+02NC 50 HZ suitable for 3.0 TR (2x1.5 TR) for split type AC having standard coil voltage of 220 volts in existing air conditioner, split type Make :- Siemens cat No. 3 TH-32
(al) Power contactor 35 Amps, single pole coil voltage 220 V/230V Model :- MR-I of Make : L&T or equivalent model of make as approved
(am) Expansion valve model No. TX-2 with 05 Nos orriface including reducer size 1/2" x 3/8" with 02 Nos flair nuts of size 3/8"
(an) Liquid line filter drier of size 3/8" to 1/2" suitable for 3.0 TR three phase split AC Make:- Sporlan /danfoss or as approved.
(ao) Pre-air filter made up of PVC for indoor unit of split AC suitable for any make and description complete
(ap) Brass service valve of 5/8" dia with flare unit in existing air conditioner split type Make CAM or equivalent make as approved
(aq) Brass service valve of 3/8" dia with flare unit in existing air conditioner split type Make CAM or equivalent make as approved
(ar) Brass service valve of 1/2" dia with flare unit in existing air conditioner split type Make CAM or equivalent make as approved
(as) Brass service valve of 1/4" dia with flare unit in existing air conditioner split type Make CAM or equivalent make as approved
(at) PVC Grills as per exisitng make of window AC Make :- LG/Carrier/Blue star/Feederllord
(au) Capacitor 4/6 mfd 230 volts for blower motor of window AC
(av) Thermostate switch with knob 230 volts for Window AC
(aw) AC electrical blower motor of 1/7 HP to 1/6 HP 230 volts 930 RPM, 3 speed Make :- Carrier/Voltas/LG/Samsung
(ax) Ventury made of thermo-coal insulation suitable for Window AC Make: LG/Videocon/Samsung
(ay) PVC fan blower assembly for 1.5 /2TR window / split AC's any make
(az) Wiring kit consisting of 2.5 Sqmm copper PVC insulated stranded copper wire with copper lugs , thimbles and solder connection complete suitable for window type AC's of any make or model
(aaa) Condenser side fan blade suitable for existing Window type AC's of make :samsung / Videocon /Carrier /Voltas/LG
(aab) Fan motor for outdoor unit suitable for inverter type split AC 1.5/2.0 TR of existing make complete
(aac) Blower motor for indoor unit suitable for inverter type split AC 1.5/2.0 TR of existing make complete
(aad) Check valve 3/8" dia for upto 2.0 TR capacity Split AC's Make :- Danfoss or equivalent make as approved by GE.
(aae) Air cooled copper condenser coil suitable for split type AC 1.5/2TR including pressure testing, vaccum testing and welding work complete all as specified and directed. Make: samsung / Videocon /Carrier /Voltas/LG
Disconnecting, dismanlting and taking out the functional air conditioner window type of any description any make and in any position 1.5/2.0 TR capacity single phase, 50 HZ and reassembling, fixing and testing the dismantled AC in new position after making necessary cutting/opening and making good in window frame of 2nd class hardwood with 6mm thick ply wood BWR grade complete all as specified and directed Note- (i) The rate for above items are deemed to include for transportation to any distance inside the AF area as appoved by Engr-in-charge (ii) Gas for charging of gas if required shall be issued free for filling under Schedule 'B'
Disconnecting,dismantling and taking out the functional air conditioner split type of any description, any make, and in any poition single/three phase 50 HZ and reassembling, fixing and testing incl installation of AC in new position/location after making necessary cutting/opening in wall and making good to match with the existing surface complete all as specified and directed Note : (i) The rate for above items are deemed to include for necessary servicing, cleaning and testing of indoor/outdoor unit of AC & replacement of necessary unserviceable screws/nuts/bolts/washer/packing's etc with new one, brazing of copper pipe & provn of PVC drain pipe of suitable size & length for split AC, transpotation to any distance inside the AF area as approved by Engr-in-charge. (ii) Gas for charging of gas if required shall be issued free of cost under Schedule 'B'.
Taking down old unserviceable MS braket of Split AC complete all as specified and directed
S&F MS factory made bracket with powder coated, fixed on wall with neccessory grouting MS bolts,washer duly painted and making good of disturbed surfaces, suitable for installing outdoor unit of 1.5/2.0/3.0 TR AC complete all as specified and directed
Taking down old unserviceable voltage stablizer of capacity 4 KVA/5 KVA
Supply and fixing voltage stablizer electronic type for automatic operation single phase naturally air cooled, indoor, type, wall mounted for input variation between 170 V to 280 V with output voltage stablized at 200V to 245 V with accuracy of + 2.5% and of capacity 5.0 KVA complete all as specified and directed Make:- Blue Bird / V-Guard or equivalent
Supply and fixing voltage stablizer electronic type for automatic operation single phase naturally air cooled, indoor type, wall mounted for input variation between 170 V to 280 V with output voltage stablized at 200V to 245 V with accuracy of + 2.5% and of capacity 4.0 KVA complete all as specified and directed Make:- Blue Bird / V-Guard or equivalent make as approved by GE.
M&L for MCB Plug and socket DBs with one MCB SP 25 /32 Amps, 10 KA, 'C' Series complete all as specified and directed Make of Plug and socket DB :- Legrand cat No. 607841 or equivalent make as approved by GE.
Taking down old unserviceable PVC cable of any conductor and any core complete all as specified and directed
S&F PVC insulated & sheathed copper round cable 1100 volts of following size incl copper thimble/pin type lugs connecting both side and testing complete all as specified and directed. Make :- L&T/Havells/Polycab (a) Size 2.5 sqmm 6 core
(b) Size 2.5 sqmm 3 core
(c ) Size 4.0 Sqmm 3 core
S&F in replacement of worn out insulating material suitable for copper tubing of split AC's of following sizes complete all as specified and directed:- (a) Internal bore 3/8" and thickness 1/4".
(b) Internal bore 5/8" and thickness 1/4"
(c) Internal bore 3/4" and thickness 1/4"
(d) Internal bore 1/2" and thickness 1/4"
(e) Internal bore 1/4" and thicel wags 1/4" Make:- Totalive/Century flex
Supplying and fixing in replacement hermatically sealed scroll compressor with in-built electric motor 3 phase 440 volt complete with oil suitable for 407/410 a Non CFC refrigerant gas etc of capacity 21/19 TR make: Danfoss including disconnecting and reconnecting with inlet and outlet refrigerant copper pipe with brazing/ soldering as required to make leak proof connection all as specified and directed.
M/S Rakesh Verma
Manish Electricals
UNIVERSAL AGENCY
lodhi builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .