Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹71.7 CrAccepted-AOC 201 ROYAL ARCADE DR B BARUAH ROAD ULUBARI GUWAHATI 781007 | GUWAHATI | KAMRUP METRO | ASSAM | 781007 | ₹71.7 Cr | L1 | Accepted-AOC Work Order Issued |
| 2 | L2₹75.0 CrRejected-AOC 14 BILASIPARA P O P S BILASIPARA DIST DHUBRI ASSAM PIN 783348 | DHUBRI | ASSAM | 783348 | ₹75.0 Cr | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not-Qualified |
| 4 | Rejected-Technical 4B TOWN SQUARE CHINAR PARK RAJARHAT KOLKATA 700 136 | - | - | Rejected-Technical Not-Qualified |
Tender Value
₹68.3 Cr
EMD Value
₹1.4 Cr
Closing Date
3 Jan 2022, 2:00 pmClosed
CE, PWD (Bldg), Assam, Chandmari, Ghy-3
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
Construction of the Annexe-II Building with Extended Floors and Including Interior and Furnishing Works at Dispur, Guwahati- 6
2021_PWBNH_23691_1
SMC/74/2021/4 Dated Guwahati the 3rd Dec 2021
Open Tender
Civil Works - Building
730 days
Dispur
Please refer Tender documents.
6 documents required · 6 mandatory
₹12,500
Assam State Road Board Maintenance (Road) Fund
₹1.4 Cr
Yes
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
23 Mar 2022
14 Dec 2021
3 Jan 2022
14 Dec 2021
3 Jan 2022
14 Dec 2021
21 Dec 2021
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kinds of soil (From 1.5 to 3 m depth)
All kinds of soil (From 3 to 4.5 m depth)
All kinds of soil (From 4.5 to 6 m depth)
All kinds of soil (From 6 to 7.5 m depth)
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : "1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size drived from natural sources).
"1:4:8 (1 cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size drived from natural sources).
Providing and laying in position ready mixed or site batched design mix concrete for plain cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland slag cement , admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength;' including pumping of concrete to site of laying, curing, carriage for all leads, but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge for the following grade of concrete. Note : Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content , the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Note : (1) Excess/less cement used than specified in this item is payable/ recoverable separately. (2) Fly ash conforming to grade I of IS 3812 (Part-1) only be used as part replacement of OPC as per IS : 456. Uniform blending with cement is to be ensured in accordance with clauses 5.2 and 5.2.1 of IS: 456 -2000 in the items of BMC and RMC." All works upto plinth level : Concrete of M10 grade with minimum cement content of 220 kg/cum
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement:3 coarse sand derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge. Upto and including 12mm dia.
Steel reinforcement for R.C.C. work ready to use "cut and bend" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2). 12 mm average thickness.
25 mm average thickness in 2 layers.
50 mm average thickness in 3 layers.
Providing & Grouting of dowel tubes / Shear keys / Joints of precast members with M-60 grade cementitious grout (Non Shrink) of approved make by suitable means ( Free flowing / pump),curing etc. Complete as per directions of Engineer-incharge. (The payment shall be made on the basis of actual weight of approved grout injected.) Stirrer mixed cementitious grout (non shrink) of approved make in dowel tubes / Shear keys / Joints of precast members.
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. without disturbing the other structural elements. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. without disturbing the other structural elements such as column, beams & slab.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
Applying Rust remover & Passivator: Cleaning of einforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. Bars upto 12 mm diameter
Bars above 12 mm diameter
Providing and supplying the one component, Polymer modifed, cementitious anti-corrosive primer, formulated to provide dual protection of a polymeric barrier and an integral corrosion-inhibiting system, to the existing steel and additional steel provided before pathcing of damaged areas, using suitable tools and equipment inclusive of Material, Manpower and Equipment. (R. A. Attached)
Providing and Applying two coats of Advanced Organo Functional Corrosion Inhibitor with proven track record, and excellent depth of penetration reacting with the concrete substrate to form a permanent chemical bond on the prepared concrete surface using brush at a consumption rate of maximum 600ml per sq.m. inclusive of Manpower, Material and Equipment. (R. A. Attached)
Providing the formwork including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts .
Providing and Pouring into the fixed leak proof formwork to repair the damaged concrete portion with high flow, single component, duel shrinkage-compensated, cementitious microconcrete that acheives a compressive strength minimum of 25 MPa at 3 day and 40 MPa at 28 days. before the bonding agent becomes tack free, inclusive of Manpower, material and Equipment. (R. A. Attached)
Providing and Repairing the damaged concrete portion with single component, fibre reinforced, duel shrinkage-compensated, thixotropic, cementitious patch repair mortar that acheives compressive strength of 35 MPa at 7 day and 45 MPa at 28 days and capable of applying 25 to 30 mm avg. thick in single layer initially by hand and finishing with trowel carefully compacting the same around the rebars and finishing to bring it in line with existing concrete surface with an average thickness of 40mm inclusive of Manpower, Material and Equipment. (R. A. Attached)
Providing and Fixng Shear connectors of 8mm dia. HYSD steel with two component, styrene & cement free, epoxy-acrylate fixing and anchoring compound supplied in self mixing Cylinder-in-cartridge form that avoids site mixing using standard sealant applicator gun after drilling holes of 12mm diameter to a minimum depth of 100mm at required locations, inclusive of all material, manpower and equipment. (R. A. Attached)
Providing and Applying a single coat of two component solvent less epoxy resin based bonding coat complying to ASTM C881 Type 2, Grade 2, and Class B &C having a open time of 6 hours and shall exceed the tensile strength of concrete in terms of its adhesive bond strength using brush or roller before the application of repairing material inclusive of material, manpower and equipment. (R. A. Attached)
Polymer Bond Coat: By using acrylic polymer, cement in 1:1 proportion or in recommended proportion as per manufacturer’s specification including cleaning the surface, wetting etc. before applying cement plaster wherever required. (R. A. Attached)
Providing and Applying Single Ply Unidirectional Glass fibre of 900GSM after necessary surface preparation including rounding off edges to a radius of 10mm, priming and satuartion of fibre as per the dry lay up process and sprinkling of sand after the final saturant application for giving protection screed on the top as per the procedure mentioned including of Material, Manpower and Equipment. (The cost of Protection Screed shall be paid in Plaster quantity). (R. A. Attached)
Fiber Shear Anchors in Beam KRISHNACONCHEM/BASF/SIKA Make Providing shear anchor of 10mm dia and 150mm long of high strength hybrid woven fiber glass fabric mesh with filling of hole with KRISHNA EPOXY or other equivalent & approved of SIKA/ BASF, removing/drawing out of the entrapped air etc. from the drilled hole all complete as per manufacturer’s specifications and directions of the Engineer in Charge. It shall include labour for mixing EPOXY resin, saturating the anchor with EPOXY, drilling the RCC members and inserting the saturated anchor inside the drilled hole and merging the bushes with the RCC members. (R. A. Attached)
Providing and Fixng standard injection packers of 10mm diameter after drilling holes of required diameter along the crack, sealing the packer with epoxy putty, removal of packer after grouting inclusive of all Material, manpower and equipment (R. A. Attached).
Grouting Nipples: Providing and inserting 12mm dia galvanised steel injection nipple in honey comb area and along crack line including drilling of holes of required diametre (20mm to 30mm) up to depth from 30mm to 80mm at required spacing and making the hole & crack dust free by blowing compressed air, sealing the distance between injection nipple with adhesive chemical of approved make and allow it to cure complete as per direction of Engineer-In-Charge.
Providing and Injecting the fixed packer two-component low viscosity (<350 cps) epoxy resin system that acheives compressive strength in excess of 55 MPa at 1 day & 65 MPa at 7 days. and shall exceed 15 MPa in slant shear bond strength with minimum pot life of 30 minutes at ambient temperatures complying with ASTM C881, Type 1 & 4, Grade 1, Class B &C using any of the standard pressure grouting methods at a maximum pressure of 2kgs/sq.cm. till refusal and allowing the epoxy grout to cure before removal of packers inclusive of cost of Material, Manpower and Equipment. (R. A. Attached)
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Stairs, (excluding landings) except spiral-staircases
Edges of slabs and breaks in floors and walls. Under 20cms wide
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position ready mixed or site batched design mix concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland slag cement , admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength;' including pumping of concrete to site of laying, curing, carriage for all leads, but excluding the cost of centering, shuttering , finishing and reinforcement as per direction of the engineer-in-charge for the following grade of concrete. Note : Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content , the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M30 grade with minimum cement content of 330 kg/cum
All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg/cum
Concrete of M30 grade with minimum cement content of 350 kg/cum
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall confirm to ASTM 6063). Floor Joint of 100 mm gap
Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). Wall Joint of 100 mm gap
Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. Roof Joint of 100 mm gap
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement Mortar 1:6 (1 cement : 6 coarse sand).
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of Slab over 0.50sqm
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick.
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/ m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded).
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/ m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately).
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-incharge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm.
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.
Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture Stainless Steel 304 grade CYLINDRICAL LOCKS - CLASSIC LOCK. Complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 300 mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete..
Toilet Cubical Providing and fixing Toilet Cubicle (of following standard dimension which includes 600 mm door size width) made of heat, bacteria, water, chemical, scratch, impact and anti bacterial resistant 12 mm thick solid compact laminate panels Finish of the compact laminate should be raw silk which include doors, pilasters and intermediate panels finished with approved texture/shade as per the detail drawing and as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard. This also includes providing and fixing in position necessary hardware made out of Stainless Steel (Grade 316) as per manufacturer's specifications and EIC instructions like (1) Door Knob, (2) Gravity Hinges, (3) Thumb turn lockset indicators, (4) Coat hooks, (5) U- Channels, (6) SS-Shoe Box Plate, (7) MS-Base Plate, (8) Rubber noise deafening tape, (9) Screws and wall Plugs.
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
Providing and fixing approved brand and manufacture SS 304 grade Top & Bottom Patch fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade H type 900mm Pull Handle with 32mm dia fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade Glass to Glass Lock Round type with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade Floor spring (weight approx 100-120kgs) fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing 12 mm thick frameless toughened glass partitions of approved brand and manufacturer, including providing and fixing partitions at top & bottom with aluminum channel etc. all complete as per direction of Engineer-in-charge
Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete. 75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG) plaster board conforming to IS: 2095: part 3 (Board with BIS certification marks)
Providing and fixing of ENVIROTECH Make , ENVIRO-WD-1, Doors is one of the best Products to Control Noise and Fulfilling a Demand of a great way in the field of Noise Reduction. DOOR FRAME: - Door frame made out of good quality hard wood , section size – 100 mm x 110 mm fitted with ‘D’ type rubber gasket to block noise leakage from gap . DOOR SHUTTER:-Providing and fixing acoustic door with minimum 60 mm thickness along with fire rating and smoke Intumescent seal strip of size 10mm x 4mm for 120 minutes fire rated and STC 37dB Tested by National Physical Laboratory, Pusa Road New Delhi and having infill of 50mm thick resin bonded glasswool of 48 kg/cum density sandwiched by two 10mm thick approved quality marine grade ply and finished with 1 mm thick laminate of approved make, shade and colour and design on both sides. Further edges of shutter shall be provided with 6mm thick teak wood beading using exterior quality synthetic adhesive, headless GI nails, screws, beading finished with approved melamine polish etc. The ply shall be resistant to vermin, mould growth, minor impact, abrasion and short term water attack and with a smooth surface suitable to receive most forms of decoration. The door shall have acoustic seal in door rebates and drop dead seal at the bottom of the door including ironmongeries.HARDWARE :-The door assembly shall be fixed to the door frame with heavy duty hardware i.e. Geze/ Assa abloy/Dorma Make or equivalent make SS Hinge Size: 4”x 3”x 3mm , 600 mm SS door handle , SS Tower bolt ,Door closer , Panic Bar ,Panic trim etc.
Automatic Sliding Door- Frameless Providing and fixing Automatic Sliding door operator, Make: dormakaba ES 200 Easy - 4.15 Mtrs Bi-parting Sliding System, compliant with European standards and produced according to the guidelines for power-operated windows, doors and gates, BGR 232, the UVV and the VDE regulations. TÜV design tested, tested according to the low voltage guidelines, production according to ISO 9001:2000 certification, fulfils DIN18650 Standards for Pedestrian Safety, TUV Design Tested for Durability of 1 Million Cycles, for frameless glass door application, modular design including internal cover. and with 12 mm clear toughened glass for 2 Nos sliding door panel, Operator to be mounted on MS-Box Section/ Equalant. Operator Finish should be Silver Anodised E6/C0, with operator dimensions Maximum (H x D) : 100 x 180 mm and of length as required to suit the opening size given below. The track profile should be separate from the main profile for enabling reduction in vibration insulation and easy maintainence. Microprocessor-controlled control unit, Self-learning, with adjustable parameters for opening and closing speed, hold-open time and opening and closing force, reversing when obstruction is encountered, Class of protection IP 20. Activators- dormakaba Nemo Motion + Nemo Dual ( Safety& Motion), EM Lock - Fail Safe and 5 Position Program Switch.The system shall have constant power supply 230V+ 5%, 50Hz, AC . The requirement in total is as mentioned below: Clear Passage Width = 700 - 2000 mm Max Clear Passage Height = 3000 mm Max Panel Weight Double Sliding = 2 x 100 Kgs. Max Panel Weight Single Sliding = 1 x 120 Kgs
Opaque Roller Shades : Providing & fixing of Blackout Roller Blinds fabric made up of 100% Polyester with Acrylic coated of 0.32mm(PVC free) of thickness 0.50mm ±5% and wieghing 270-295gsm with openess factor of 0% .Shrinkage % Warp<0.5 & Weft <0.5,Color fastness>5-6. The control clutch drive unit engineered heavy duty chain drive pulley operating system consisting of gear clutch housing and locking plug containing minimum 6 ribs and inserted at minimum of 37mm into roller tube. It is self-lubricating Exclusive clutch with safety pins for secure bracket installation and unlocking pin for quick manual removal. Universal clutch is most convenient for large windows down to the smallest windows. It shall be driven by a ball chain pulley with ball chain and can be positioned at Right hand or Left hand side of the shade. Clutch gear ration 1.75:1 for reduced operating force on larger blinds. Tube bearing plug idler Exclusive self-lubricating spring loaded plastic bearing end plug with positive locking wheel allows for adjustment and provides for a secure installation and removal of shade. Tube bearing plug contain minimum 6 ribs and inserted a minimum of 37mm into roller tube. Mounting hardware brackets universal brackets including end plug bracket with lock down retainer device. Brackets finish of powder coated metal installation brackets made of stamped and hardened steel with 46mm projection for wall, ceiling and side fitting with screws and end cap covers. Roller tube circular-shaped aluminum tube extruded from alloy 6060 and temper T66 – EN755 of 37mm inside diameter and outside diameter 40.2mm extruded tube to have a 1.6mm wall thickness with standard anodized natural finish. Heavily reinforced with minimum six internal ribs providing additional tensile strength and allows for secure placements of clutch and end plug. Bottom rail flat-shaped extruded aluminum from alloy 6060 and temper T66 – EN755 of dimension 13mm * 30mm and wall thickness of 1.5mm and weight of 390g/m. Rail standard finish of powder coat white color and provided cover. Ball chain shall be 2mm diameter cord with 4.5mm diameter acetal balls molded coaxially to it on 11.8mm pitch to form an endless ball chain. It is used for raising or lowering action of the shades. Plastic parts all plastic components are UV-stable compounds available white colour.
SITC, of Argus Sensor Swing Barrier Normal Lane (2) and Wide Lane (1):- (1) Two wings/door leaves are made of transparent polycarbonate with 10 mm thickness, upper edge 900 mm with opening/ closing time of 0.3 seconds minimum, which can be adjusted as per client requirement. (2) Design: The housing and the base columns are made of AISI 304 stainless steel with semigloss. Finish: Stainless steel semi-gloss smooth finish. (3) Function: The sensor barrier is equipped with two servo positioning drives (low energy drives with energy content <1.6 joules) along with Tooth holding brake technology and is electrically controlled in both directions thus guaranteeing a particularly high level of personal safety. The unit can be locked in any position (Tooth Holding Brake Technology) and opens under load (personal safety in case of panic). In basic position, the unit is unlocked to minimise power consumption. (4) Standard measurements: Total width: 1,070 mm, passage width: 650 N/900 W mm, interlock height: 945 mm & wings height 1300 mm and total length 1660 mm (5) MCBF: Complete swing flap barrier unit/system. MCBF (mean cycles between failures) is 10 million for 650 mm passage width and 8 million for 900mm passage width. (6) standby power consumption 17 VA. DormaKaba Argus HSB- E07- Normal Lane (2) and Wide Lane (1)
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Extra for providing mechanical device chain and crank operation for operating rolling shutters. Exceeding 10.00 sqm and upto 16.80 sqm in the area
Exceeding 16.80 sqm in area
Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- charge, (area of grill to be measured).
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slabs
Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre .
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades including tile fixing chemical adhesive grouting the joint with Epoxy grout etc., complete. Full Body Vitrified floor tile 800x800 mm Size of Tile 800x800 mm
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 800x800 mm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent
Extra for pre finished nosing to treads of steps of Granite stone.
Extra for Granite stone flooring in treads of steps and risers using single length up to 2.00 metre .
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Carpet flooring Providing & Fixing of Flocked textile floor covering of Nylon 6.6 face fiber or equivalent of approved make with 100% Nylon and completely water proof resilient backing. The flooring should be Anti static with thickness of 4.3 mm, and approximate weight of 1.8 k.g./sqm of roll form. The carpet should be completely stain resistant and of a density approx. 80 million fibers/sq.mtr (70 million fiber/sq.yd) in the width of 2 mtr .The floor covering should have Fire Test EN-13501, Appearance Retention Hexapod ISO 140-8, Friction Slip Resistance Test EN 14041 Class DS, SANITISED anti-microbial treatment, with resilient waterproof backing, anti allergic which is certified by British allergy foundation, with ten year replacement guarantee. The carpet should have permanent static control & should be fixed with powder coated aluminum angles as per detail
Providing and Installation of acoustical wall panelling fabric finish hardened square edge, FR grade fabric (colour as approved by Egnineer in charge) wrapped soft fibre core (glass fibre) panel of size 600x2100x25mm having density 100-120Kgs/ m3, weight 3.0kg/m2 NRC up to 0.9 installed by using impaling clip. Impaling clips are attached directly to the wall/frame work with the points extending outward . Then panels shall positioned and pressed into place .
Providing and installation of paintble acoustic wall panelling consisting of Strand kerfed edge paint finished as approved by Engineer in charge. magnesite bonded wood fiber panels of size 600x2400x20mm having density 400kg/m3, weight 8-20kg/m2 which is fixed to GI strut system. The GI strut work includes Cross channel having thickness 0.45mm, length 3600mm, knurled web 40, depth 10mm and equal flanges 15mm is fastened to wall positioned horizontally in a regular manner at 600mm centers. PVC Vinyl core UV treated H-Spline having thickness 2mm and length 2400mm to be fixed perpendicular to the Cross channel at 600mm centers. The Kerfed edge panels shall be then inserted into the H-spline against wall to perfect fit.
Providing and installation of acoustic wall panelling consisting of Stretch NRC by using FR Grade NRC fabric of size 1700mm width, shall be stretched by using wooden base 10mm thick, rigid vinyl Stretch Tracks half wrap/ full wrap 25mm and Midseam 25mm , strand, synth PF with requisite accessories and tools. Woodenbase 10mm is first installed on the wall along the marking lines with metal fasteners at 300mm centers . tracks to be installed on wooden base, by using Base tape (by removing the protective cover) for a true and continuous secure grip, and heavy-duty fasteners at 15mm centers on one/both sides of Stretch Tracks. Strand square edge magnesite bonded wood fiber panels of size 600x1200x15mm having density 400kg/m3, weight 4-8kg which is fixed to wall. Synth PF 10x10mm thick adhered on strand panel by using Stick 7 adhesive. Fabric of width 1700mm is then aligned to the Stretch tracks by following the fabric thread line or pattern. The fabric is stuck on the Align Tape (by removing the protective cover) at the same time as being stretched and tucked into the Stretch tracks and secure into the locking jaws so that it will be smooth, free of wrinkles with the tucking tools. Note -minimum 50mm additional fabric is required for tucking hence maximum module width would be 1600mm. 12 mm cement plaster of mix : 1:6 (1 cement : 6 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement : 6 fine sand)
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 10 to 13 m
Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). Red sand stone - 30mm thick gang saw cut stone
Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300 mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineerin- charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid).
Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-in-charge.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm.
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats.
Providing & fixing 150mm wide Chicken wire mesh on joints of RCC & Brick work before plastering complete in the direction of Engineer-in-charge.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer
Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls,reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer's specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @ 0.70 kg per sqm
For horizontal surface one coat @1.10 kg per sqm.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Providing and laying broken AAC Block in sunken portion of W.C. & kitchen. These broken Block mixed with cement mortar 1:8 ( 1 cement : 8 coarse sand) laid and compacted properly including supply of labour, material, and tools and plant etc. as per instruction of Engineer-in-charge.
Grading roof for water proofing treatment with Cement mortar 1:4 (1cement : 4 coarse sand)
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75 x75 mm deep chase
Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight of approved grout injected.) Epoxy injection grout in concrete/RCC work of approved make
Providing and placing in position suitable PVC water stops conforming to IS:12200 between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc complete. Serrated with central bulb (225mm wide,8-11mm thick)
Grading roof for water proofing treatment with Cement mortar 1:4 (1cement : 4 coarse sand)
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS :1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and laying roof insulation with 40 mm thick impervious sprayed, closed cell free Rigid Polyurethane foam over deck insulation conforming to IS - 12432 Pt. III (density of foam being 40-45 kg/cum), over a coat of polyurethane primer applied @ 6-8 sqm per litre, laying 400 G polythene sheet over PUF spray and providing a wearing course of 40 mm thick cement screed 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) in chequered rough finish, in panels of 2.5 m x 2.5 m and embedding with 24 G wire netting and sealing the joints with polymerized mastic, allcomplete as per direction of Engineer-in-Charge.
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : For fixed portion Powder coated aluminum (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminum (minimum thickness of powder coating 50 micron)
Providing and fixing Single Glazing 6mm thick ET 125 series (Saint Gobain) toughened glass complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor ≤ 0.45, U-Value ≤ (W/sq.m-K) 5.7W /M2K, Visible light transmittance ≥ 0.30)
Filling the gap in between aluminum frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width
Providing and fixing 50 micron thick Etching strips (film) over glass Non-fade, self adhesive,easy to cut and trim to size and easy to install, of approved make and manufacturer, fixed as per manufacturer's specifications and as specified in Arch. drawing, all complete in all respects as per direction of the Engineer-in-charge.
Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick button wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3) : 1996 (Board with BIS certification marks)
Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gsm/sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main "T" at 600mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 x mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum),including factory painted after bending and perforation,and backed with a black Glass fiber acoustical fleece.
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long Dry Wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/ mK.
Providing and Fixing of 16.5mm thick Micro perforated wooden acoustic panel of size - 600mm x 1200mm / 600mm x 2400mm , front side perforation diameter will be 0.5mm – 0.7mm at a distance of 02 mm c/c and backside 10mm dia. as per acoustic design / Architects approval, The micro perforated wooden acoustic panels to be backed with black acoustic fleece. All joints of panel shall have dowel connection to avoid any sagging /unevenness. The wooden acoustic panels to be fixed on specially designed Powder Coated ‘C’ Channel supported from RCC slab with steel wire / threaded rod. The micro perforated top sheet will be of 0.5mm thick Mica laminate in desired shade as per Engineer In charge / Architect’s approval. The top cavity of ‘C’ channel grid shall be filled with 25mm thick Acoustic pillow to achieve the 1.0 NRC value. All makes and models of all items/samples should be approved by the engineer-in-charge / consultant prior to the installation.
Providing and fixing U Baffle Aluminium panel ceiling (M/s Hunter Douglas or Equivalent) consisting of Wood finish panel size 30 mm width X 100mm deep using 0.6mm thick, panel length upto 4 mtr, Coil Coated on a Continuous Paint Line, Double baked and roll formed from enamelled corrosion resistance Aluminium alloy AA 3005 (Al. Mg) for higher strength and good roll forming characteristics. Panels shall be clipped to a baked enamelled Aluminium carrier of 30 mm wide x 47 mm high x 0.5 mm thick, Black Colour coated, one leg of the carriers with cut outs to hold the panels in a module of 150 mm. Panel carrier shall be suspended by means of threaded rod at a distance of 1.8 mtr c/c. Aluminium panels shall be chromatised for maximum bond between metal and paint enamelled twice under high temperature, Exposed side with a full primer and finish coat on a Continuous Paint Line. Ceiling area above U Baffle to be painted in black colour before fixing this system (Cost of black paint shall be paid separately).
Providing & fixing access panel is made out of Moist Bloc (Moisture Resistant) board for opening 600 x 600mm of thickness 12.5mm. All edges of the panel are reinforced with aluminium profiles and corners are guarded with stainless steel 304 grade clips to increase strength and prevent damages. complete in all respect as directed by Engineer-in-charge.
Designing, providing, installing / fixing skylight consisting of 16mm thick multiwall polycarbonate sheet "Danpalon" or equivalant in approved color (minimum 900mm wide) with standing seam on both sides & double tooth snap on locking system to ensure maximum uplift capability. The panel shall be co-extruded UV protected and antiglare / softlight to prevent glare/sun streak . The cross section of one cell should not be more than 4mmX4mm & weight of single panel shall not be less than 3250 per square metre. The system shall be fitted on purlins with spacing as specified by manufacturer with stainless steel fastener & screws and supported on MS tube framework, complete as per specification, drawing and direction of Engineer in Charge. The rate includes cost of all the operations,labour materials and tests (as applicable) for proper completion of the work except the M.S tubular framework which shall be measured and paid separately (For payment purpose the area of finished polycorbonate sheet fixed in position shall only be measured).
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places.. Note:- 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories 6) Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.“(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2)“For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.“ Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.
Sanitary Fixtures & CP Brass Fittings Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm, bowl depth 200mm.
Kitchen sink with drain board 510x1040 mm, bowl depth 200mm.
Kitchen sink with out drain board 610x510 mm, bowl depth 200mm.
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia
Providing and fixing P.V.C. Waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm dia.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing toilet paper holder : C.P. brass
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings wooden cleats with CP brass screws with concealed fittings 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
Providing vitreous china counter top wash basin of size (635 x 390 x 140mm) of Parryware modal C0457 Semi-Insert with 32 mm CP brass waste coupling of standard pattern, C.P. brass chain with plug, PVC waste pipe including painting of fittings and brackets, cutting and making good the walls and slabs wherever required. White vitreous china counter top wash basin with CP Brass Single Lever Basin Mixer.
White vitreous china counter top wash basin with CP CP Brass Single Pillar Cock.
Providing and fixing 15mm C.P brass Sink Mixer for kitchen sink of Parryware Model. No.T3950A1 with swinging spout complete. Including cutting and making good the walls wherever required .
Providing, fitting and fixing chrome plated (CP) twin robe hook of Parryware modal T6007A1 complete as directed and specified.
Providing and fixing 15mm C.P. copper connecting pipe 450mm long of Parryware modal T991299 with C.P. brass nuts, washers complete in all respects.
Providing and fixing health faucet with 1 m long of Parryware modal T9807A1 flexible tube and wall hook including all fittings.
Providing and fixing of C.P. brass Soap Dish fixed with C.P. brass screws complete in all respects.
Providing and fixing vertical storage type hot water heater fixed to wall with anchor bolts & nuts, 15mm CP brass angle stop cock and 15mm CP brass non-return valve complete including making connections with 15mm dia CP connecting pipes on inlet and outlet, suitable length of power cable and 15 amps plug (Venus or approved equivalent). Capacity 25 Litres
Providing and fixing vertical storage type hot water heater fixed to wall with anchor bolts & nuts, 15mm CP brass angle stop cock and 15mm CP brass non-return valve complete including making connections with 15mm dia CP connecting pipes on inlet and outlet, suitable length of power cable and 15 amps plug (Venus or approved equivalent). Capacity 70 Litres
Providing and fixing C.P. brass 15 mm nominal bore two way bib cock.
Providing and fixing fully automatic Hand dryer including all fittings complete in all respect.
Providing and fixing Grab Bar or approved equivalent,Including cutting and making good the walls wherever required
Providing and fixing 40 litre/ hr. cooling and 80 Litres storage capacity,fully stainless steel electric storage type water cooler (Blue Star model No. SDLX 480 or equvalant) with inlet hose connection inbuilt float valve. 2 Nos. outlet foucet, drain tray with waste and pipe up to fllor trap heavy compressor and wire up to socket, 3 pin plug etc complete in all respect.
Supplying, installation, testing and commissioning of skid mounted fully automatic Reverse Osmosis System of output capacity 50 litres / hour designed at a minimum Flux at inlet complete as required.
Soil, Waste, Vent & Rain Water Pipes Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering. All work up to plinth. 1:2:4 ( 1cement : 2 Coarse sand : 4 graded stone aggregate 20 mm nominal size )
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing and fixing soil, waste and vent pipes : 100 mm dia. Hubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS: 15905
Providing and fixing soil, waste and vent pipes : 75 mm dia. Hubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS: 15905
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts & nuts complete. 100 mm dia. Hubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS: 15905
Providing and fixing plain bend of required degree. 100 mm dia. Hubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS: 15905
Providing and fixing plain bend of required degree. 75 mm dia. Hubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS: 15905
Providing and fixing heel rest sanitary bend 100 mm dia Sand cast iron S&S as per IS - 3989
Providing and fixing double equal plain junction of required degree. 100x100x100x100 mm Hubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS: 15905
Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100x100x100 mm Sand cast iron S&S as per IS - 3989
Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 75x75x75 mm
Providing and fixing single equal plain junction of required degree. 100x100x100 mm Hubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS: 15905
Providing and fixing single unequal plain junction of required degree. 100x100x75 mm Hubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS: 15905
Providing and fixing terminal guard. 100 mm Hubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS: 15905
Providing and fixing terminal guard. 75 mm Centrifugally cast (spun) Iron S&S as per IS: 3989
Providing and fixing shieled coupling for Hubless centrifugally cast iron pipes. 100 mm dia. SS 304 grade coupling with EPDM rubber gasket.
Providing and fixing shieled coupling for Hubless centrifugally cast iron pipes. 75 mm dia. SS 304 grade coupling with EPDM rubber gasket.
Providing and fixing MS Stay clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter. 100 mm dia
Providing and fixing MS Stay clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter. 75 mm dia
Providing and fixing trap of self cleansing design with screwed down or hinged with or without vent arm complete, including cost of cutting and making good the walls and floors. 100 mm inlet and 100 mm outlet Hubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS: 15905
Painting sand cast iron/ centrifugally cast (spun) soil, waste, vent pipes and fittings with paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work. 100 mm diameter pipe
Painting sand cast iron/ centrifugally cast (spun) soil, waste, vent pipes and fittings with paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work. 75 mm diameter pipe
Painting sand cast iron/ centrifugally cast (spun) soil, waste, vent pipes and fittings with paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work. 150 mm diameter pipe
Providing and fixing G.I. pipes complete with G.I. Fittings and clamps, including cutting and making good the walls etc. (Internal work) 32 mm dia. nominal bore
Providing and fixing G.I. pipes complete with G.I. Fittings and clamps, including cutting and making good the walls etc. (Internal work) 50 mm dia. nominal bore
Painting GI pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. 32 mm dia. nominal bore
Painting GI pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. 50 mm dia. nominal bore
Providing and fixing soil, waste and vent pipes including all fitting and jointing system. 150 mm dia. Hubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS: 15905
Providing and fixing of GI clamps with EPDM rubber lining Zinc plated for support of vertical soil, waste, vent and rain water pipes, embedded in walls with anchor fastner etc. including cost of cutting holes and making good the walls complete in all respects. For 75 mm Pipe
Providing and fixing of GI clamps with EPDM rubber lining Zinc plated for support of vertical soil, waste, vent and rain water pipes, embedded in walls with anchor fastner etc. including cost of cutting holes and making good the walls complete in all respects. For 100 mm Pipe
Providing and fixing of GI clamps with EPDM rubber lining Zinc plated for support of vertical soil, waste, vent and rain water pipes, embedded in walls with anchor fastner etc. including cost of cutting holes and making good the walls complete in all respects. For 150 mm Pipe
Providing and fixing cast brass clean out plug with suitable insert keys for opening, male threaded joint with GI threaded socket caulked to CI soil pipe including cost of lead Joint. 100 mm dia
Providing and fixing cast brass clean out plug with suitable insert keys for opening, male threaded joint with GI threaded socket caulked to CI soil pipe including cost of lead Joint. 150 mm dia
Providing and fixing in position 100x50 mm dia GI reducing elbow including fix to floor with cement mortar.
Providing and fixing in position 125x125 mm stainless steel grating for floor trap/floor drain including fix to floor with cement mortar.
Providing and fixing 100 mm dia GI inlet fitting/ Extension Piece with 2 or 3 inlets of 32 to 50 mmdia, fixed to CI trap with lead joint and set in cement concrete as per drawing complete.
Providing and fixing uPVC agricultural pipes conforming to IS:4985 (6 kg/sqcm) including all fittings, e.g. couplings, tees, bends, reducers and screwed adoptors jointing with solvent cement joint as per manufacturers' recommendations. [for Rain Water Pipes] 110 mm OD
Providing and fixing uPVC agricultural pipes conforming to IS:4985 (6 kg/sqcm) including all fittings, e.g. couplings, tees, bends, reducers and screwed adoptors jointing with solvent cement joint as per manufacturers' recommendations. [for Rain Water Pipes] 160 mm OD
Water Supply System Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. a) 20 mm nominal outer dia .Pipes.
b) 25 mm nominal outer dia .Pipes.
c) 32 mm nominal outer dia .Pipes.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall a) 20 mm nominal outer dia .Pipes.
b) 25 mm dia nominal bore
c) 32 mm dia nominal bore
d) mm dia nominal bore
e) 50 mm nominal dia .bore
f) 65 mm dia nominal bore
g) 80 mm dia nominal bore
h) 100 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work a) 40 mm dia nominal bore
b) 50 mm dia nominal bore
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : a) 20 mm dia nominal bore
b) 25 mm dia nominal bore
c) 32 mm dia nominal bore
d) 40 mm dia nominal bore
e) 50 mm dia nominal bore
f) 65 mm dia. nominal bore
g) 80 mm dia. nominal bore
h) 100 mm dia. nominal bore
Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 40 mm dia nominal bore
Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 50 mm dia nominal bore
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 40 mm dia nominal bore
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 50 mm dia nominal bore
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required 80 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required 100 mm dia
Providing and fixing forged brass ball valve of brass body with hard chrome plated steel ball inside PTFE (Teflon) seat & ring with chrome plated centre handle with female BSP threads complete in all respects. a) 20 mm nominal bore
b) 25 mm nominal bore
c) 32 mm nominal bore
d) 40 mm nominal bore
e) 50 mm nominal bore
Providing and fixing Thermoflex or Kaiflex thermal insulation tubing a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification. 6 mm thick (Concealed Pipes) For 20 mm Pipe
Providing and fixing Thermoflex or Kaiflex thermal insulation tubing a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification. 6 mm thick (Concealed Pipes) For 25 mm Pipe
Providing and fixing Thermoflex or Kaiflex thermal insulation tubing, a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including protection by wrapping with 24 gauge alumminium sheet with riveted screw joints all required accessories complete as per specification. 13 mm thick (Exposed Pipes) For 25 mm dia Pipe
Providing and fixing Thermoflex or Kaiflex thermal insulation tubing, a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including protection by wrapping with 24 gauge alumminium sheet with riveted screw joints all required accessories complete as per specification. 13 mm thick (Exposed Pipes) For 32 mm dia Pipe
Providing and fixing forged brass single acting air release valve with screwed inlet 25 mm dia.
Providing and fixing of Single phase electrical actuator operated wafer type rubber lined butterfly valve with by pass arrangement as per drawing attached including level controller, 3 nos. normal butter fly valves,necessary control and Power cables ( Maximum 10 M. Length of each type) and control panel installed on OH tank filling line near the tanks complete in all respects. 40 mm dia.
Providing and fixing of Single phase electrical actuator operated wafer type rubber lined butterfly valve with by pass arrangement as per drawing attached including level controller, 3 nos. normal butter fly valves,necessary control and Power cables ( Maximum 10 M. Length of each type) and control panel installed on OH tank filling line near the tanks complete in all respects. 50 mm dia.
Providing and fixing threaded end brass digital water meter complete in all respect. 40 mm dia.
Providing and fixing threaded end brass digital water meter complete in all respect. 50 mm dia.
Sewerage System Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. All kinds of soil Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia.
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5m, but not exceeding 3m. (Rate is over corresponding basic item for depth upto 1.5 metre). Pipes, cables etc, exceeding 80mm dia but not exceeding 300mm dia
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Extra for every additional lift of 1.5m or part thereof in: All kinds of soil (Manhole)
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all round S.W. pipes including bed concrete as per standard design. A) 150 mm diameter
B) 200 mm diameter
C) 250 mm diameter
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 180x150 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing, laying and jointing HDPE Double Wall Coil (DWC) SN-8 Grade pipes confirming to IS: 16098 including all fittings wherever required e.g., tees, bends of any degree, couplings, adapters, plugs, unions etc. and jointing as manufacturer recommondation etc. including testing of joints etc. complete. A) 160 mm OD
B) 200 mm OD
C) 250 mm OD
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes : Size 90x80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonary circular type manhole 0.91m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1 :3:6 mix (1 cement : 3 coarse sand : 6 graded 40mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement all complete as per standard design: 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560mm internal diameter confirming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 0.91m internal dia (at bottom) with beyond 0.91m to 1.67m. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry circular manhole 1.22m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond 1.68 m to 2.29 m : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Supply of Grease separator ECO-JET-OD NS 04 with sludge trap capacity 400 Ltrs. according to DIN EN 1825, for free standing installation, of polyethylene, material LLD-PE, with grease storage capacity 200 liters, total wastewater capacity 830 liters, with direct suction, with connecting flange DN 65 PN 10 For local suction line R 2 1/2”, with fire hose quick coupling B with 2 odour proof maintenance openings DN 350 inlet and outlet DN 100. With max dimensions: 770x2000x1680mm With Inspection Windows & Filling Device.(Make : ACO Part No. 3554.64.41 or Equivalent)
Storm Water Drainage Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. All kinds of soil Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Extra for every additional lift of 1.5m or part thereof in: All kinds of soil (Manhole)
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) up to haunches of S.W/RCC pipes including bed concrete as per standard design. 250 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) up to haunches of S.W/RCC pipes including bed concrete as per standard design. 300 mm diameter
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm dia. R.C.C. pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 300 mm dia. R.C.C. pipe
Constructing brick masonary circular type manhole 0.91m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1 :3:6 mix (1 cement : 3 coarse sand : 6 graded 40mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement all complete as per standard design: 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560mm internal diameter confirming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 0.91m internal dia (at bottom) with beyond 0.91m to 1.67m. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Constructing bricks masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
WATER SUPPLY & DRAINAGE PUMPS AND WATER TREATMENT EQUIPMENTS Supply, installation, testing & commissioning of vertical inline multistage pumping set (Imported) with Stainless steel body, impeller, casing, shaft and C.I. base & head with mechanical seal, connected to a TEFC induction motor suitable for 415+/- 10% volts, 3 phase 50 cycles A.C. supply with 150 mm dia pressure gauge with gunmetal isolation cock, vibration eliminating pads under foundations, Control Valves, Non return Valves,80x40 mm I section base plate bolted to cement concrete foundations complete.Vendor to submit performance curves and technical catalogue of the proposed model for review and information. Filter Feed Pump ( Dom. Water) at Water Supply Pump Room Set of Two Pumps ( 1 Working+ 1 Standby) Capacity 2.0 LPS Head 25 M. HP 1.5 HP Approximate
Domestic Water Transfer Pump at Water Supply Pump Room Set of Two Pumps ( 1 Working+ 1 Standby) Capacity 2.0 LPS Head 55 M. HP 3.0 HP Approximate
Flushing Water Transfer Pump at STP Set of Two Pumps ( 1 Working+ 1 Standby) Capacity 1.5 LPS Head 55 M. HP 2.0 HP Approximate
Irrigation Pump at STP Set of Two Pumps ( 1 Working+ 1 Standby) Capacity 1.5 LPS Head 40 M. HP 1.5 HP Approximate
Supply, installing, testing and commissioning of submersible open impeller non-clog pumps with C.I.body and to TEFC submersible motor for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical discharge pipe, guide pipe and chain in built level controller, sequence running controller, arrangement for both pumps together inacase of emenegency, audible hooter for failure or flooding, dry running Protection, control valves, Non return valves complete in all respects., painting, testing and commissioning complete with approved quality and make as required as per instruction of site incharge. (Pumps shall be installed in a set of two pumps One working and One standby) Pump Room Drainage Sump Pumps (Pumps to be suitable to handle solids upto 30 mm size) Capacity - 4.0 LPS (Each) Head - 15 M H.P. - 1.5 HP Approx.
STP Room Sewage Sump Pumps (Pumps to be suitable to handle solids upto 50 mm size) Capacity - 4.0 LPS (Each) Head - 15 M H.P. - 2.0 HP Approx.
Supply Installation,Testing & Commissioning of vertical self supporting Filter fabricated from MS sheet as per IS: 2825, ((minimum thickness of shall 6 mm and dished end 8 mm)) pressure gauges, sample cock, GI class 'C' face piping, CI butterfly valves and all accessories , with initial charge of filter media including anthracite, painting inside with epoxy paint and outside with two coat of red oxide primer and two or more coat of synthetic enamel paint, testing and commissioning complete. Dual Media Filter For Domestic Water Supply Capacity- 7200 LPH Filtration rate- 14000 LPH/Sqm. Filter dia approx. - 800 MM Working pressure: 3.0 Kg/sq cm. Test pressure : 4. 5 Kg/sq cm
Activated Carbon Filter For Domestic Water Supply Capacity- 7200 LPH Filtration rate- 14000 LPH/Sqm. Filter dia approx. - 800 MM Working pressure: 3.0 Kg/sq cm. Test pressure : 4. 5 Kg/sq cm
Supply Installation,Testing & Commissioning of metering pump type chemical doser with 100 lits. HDPE chemical grade solution tank,injection fitting assembly,suction and delivery hose upto the point of injection, capacity 0-6 lph, complete in all respects. Chlorination of Domestic Water
Supplying, installing, testing and commissioning controllers with low voltage relays, stainless steel probes and PVC shroud wiring from tank top to problems of required. For Water Supply Pump: To start pump when water level is low in Domestic Water U.G. tank and shut off pump when Domestic Water U.G. tank is full. Also to stop when water level is low in raw water underground tank.
For Sump Pumps: To start pump when water level is high in sump and shut off pump when sump is empty. Both pumps are start when sump is over flowing.
Providing and fixing resilient rubber neoprene lined style arch vibration eliminators suitable for raw water upto 45 deg.C. Temperature working pressure upto 25 Kg/Sqcm. 50 mm dia
Providing and fixing resilient rubber neoprene lined style arch vibration eliminators suitable for raw water upto 45 deg.C. Temperature working pressure upto 25 Kg/Sqcm. 65 mm dia
Providing and fixing heavy duty armoured cables 1.1 KVA grade including necessary support clamps at ceiling level and connection lugs complete in all respects. Power cable Copper 3 core 6 sq.mm
Providing and fixing heavy duty armoured cables 1.1 KVA grade including necessary support clamps at ceiling level and connection lugs complete in all respects. Control cable copper 2 core 1.5 sq.mm
TUBEWELLS Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 ( 1cement : 2 Coarse sand : 4 graded stone aggregate 20 mm nominal size )
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, upto 90 metre depth below ground level. All types of soil 400 mm dia
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 400 mm dia
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mm
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp.
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia
Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80 mm dia.
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 80 mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : 80 mm dia
Supply, Lowering, installation & testing of KSB make submersible pumping set with 10 HP to 15 HP motor 4/5 stage pump suitable for 45-60 m3 hr. at 60 to 100 mtr. Head respectively. With Three Phase.
Providing & fixing submersible aluminium cable 10 sq.mm. from submersible pump to panel board.
Providing & fixing Panel Board for submersible pump fitted with DOL starter ammeter, voltmeter single phase preventer standard/indo/cop make MCB of off switch push bottom duly wired and made out of 16/18 SWG sheet.
Fire Fighting & Sprinkler System Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : A) 25 mm dia
B) 32 mm dia
C) 40 mm dia
D) 50 mm dia
E) 65 mm dia
F) 80 mm dia
G) 100 mm dia
I) 150 mm dia
Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80 mm dia.
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : A) 80 mm dia
B) 150 mm dia
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : 150 mm dia
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 150 mm dia
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304)
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 40 m
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for nstantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304)
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Upright Sprinkler
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Concealed sprinkler
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 150mm dia
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 150mm dia
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width x 50mm depth x 1.6 mm thickness.
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. a) 700mm
Providing and fixing of Weather proof hose cabinets fabricated from 14 g M.S. Sheet with full glass door and mortise locking arrangement , suitable to accommodate one Hydrant landing valve, 2 nos. 15 M long hose and 1 No branch pipe. The cabinet shall be painted with one coat of primer and finished stove enamelled "Fire Red", "Fire Hose" written on front including suitably mounted on a raised masonry platform as required. (Approx 0.75mx0.6 m x 0.25 m).
Providing and fixing MS partly glazed single/double hung lockable shutter fabricated from MS section as required with 5 mm thick glass for fire station complete including stove enamelled painting of door and frame and words "Fire Hydrant" written on glass, suitable to accommodate 2 Hydrant landing valves, 1 fire hose reel, 2 nos.15m long 63 mm dia hose,1-branch pipe, 1no. fire man's axe, fire extiguishers 2 nos, including suitably mounted on a raised masonry platform as required. (Approx.size 0.90 m x 2.1m )
Providing and fixing carbon-di-oxide type fire extinguishers consisting of pressure tested single cast cylinder with rotary discharge valve and high pressure discharge tube of minimum 1 m length, discharge horn, suspension bracket conforming to IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge (Halon Free Gas) Capacity 4.5 Kg.
Providing and fixing ABC Powder type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. (Halon Free Gas) Capacity 6.0 Kg.
Gas Suppression System Note: The below quantities are indicative only, the final piping design and pressure calculationsusing manufacturer design software for a given dimension of room duly approved by manufacturer/ distributors shall be submitted prior to starting of the works. Supply of Cylinder UL listed / CCOE Approved, complete with UL listed valve assembly and including supervisory switch for monitoring cylinder pressure,a pressure guage with a safety burst disc ,electronic control head / Solenoid, pressure operated control, head, flexible hoseand a safety cap. Gas.(Quantity would be as per the volume given above and as per the UL certification.) CLEAN AGENT FK-5-1-12 (NOVAC 1230/NAF S 1230) (UL Listed) with Zero Ozone Depletion Potential(ODP), has appearance/colour: Colourless gas SERVER ROOM 1 X 68 Litres (Or as per OEM UL approval) Working Cylinder duly filled with FK-5-1-12 (NOVAC 1230/NAF S 1230) (66 kgs approx.)
Discharge Nozzle ( Ul Listed ) caliberated as per Computer Generated Results.
Supply of Piping with ASTM sch. 40 pipe as per design requirment complete with required welding work with Required sizes making good the damages etc as reqd.
Performing room integrity test for each room
FIRE FIGHTING PUMPS Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : a. Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. b. Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type wit c. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.h Class-'F' insulation, conforming to IS-325. d. Suitable cement concrete foundation duly plastered with anti vibration pads. 2850 lpm at 88 m Head
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) a. Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Description of Item DSR b. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. c. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. d. Suitable cement concrete foundation duly plastered with anti vibration pads. 2850 lpm at 88 m Head
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads. 180 lpm at 88 m Head
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) a. Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b. Suitable HP squirell cage induction motor TEFC typesuitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. c. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 900 LPM at 35 m Head
Supply, Installation, Testing & Commissioning of double flanged vertical air vessel fabricated shell from 10 mm thick & dished ends 12 mm thick M.S.plate, suitable for working pressure of 18 kg/cm2 and test pressure of 27 kg/cm2, 450 mm dia and 2.00 m high for fire pumps complete with four nos dual setting pressure switches to operate jockey and main pumps at drop of pressure as given in the specifications.
Providing & fixing 150 mm diameter MS Class ‘C’ for diesel engine exhaust pipe (including all fittings, clamps, steel support) of suitable dia for the diesel engine. The pipe shall be provided insulation with fibre glass wool and wraped with 24g. aluminium sheet complete with all respect.
Providing and fixing resilient rubber neoprene lined single arch vibration eliminators with unit control suitable for raw water upto 450C temperature working pressure 25 kg and test pressure 37.5 kg/cm2. a) 80 mm dia
b) 100 mm dia
c) 150 mm dia
Providing and fixing heavy duty PVC insulated, PVC armoured conductor cables 1100 V grade including necessary support clamps and connection lugs complete in all respects. Power cable 3.5 core 150 sq mm aluminium conductor armoured cable
Power cable 3 core 16 sq mm aluminium conductor armoured cable.
Control cable copper 2 core 1.5 sq.mm
Providing and fixing 25 mm dia inspecting & testing assembly with drain valve built in bye pass arrangement and connection to drain line. (Giocomini)
POINT WIRING Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required 6 x 1.5 sq. mm
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying & Fixing call bell suitable for single phase,230V complete as required
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-C
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required.
SUB MAIN CABLES Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. i) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
ii) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
iii) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
iv) 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
v) 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
vi) 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
WIRING FOR TELEPHONE SYSTEM & TV SYSTEM Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. i) 20 mm
iii) 32 mm
Supplying and fixing of following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. i) Telephone socket outlet
ii) TV antenna socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75 mmX75 mm)
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, armored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 10 Pair
Supply installation and testing and commissioning of follwing size of Telephone distribution board in a M.S. box with hinged cover/ door complete with krone type tag block with double jumpering facility mounted on a bakelite sheet etc. including terminations of cable as required. i) 10 Pair telephone distribution board
ii)20 Pair telephone distribution board
iii) 30 Pair telephone distribution board
iv) 50 Pair telephone distribution board
Supply and laying of coaxial cable RG-59 in existing conduit complete as required.
Supply, erection, testing & commissioning of following sizes of splitters of aluminium die cast body. i) 6 Way
Supply and fixing of following modular switch socket on the existing modular plate & switch box including connection but excluding modular plate and Modular box etc as required. 20 Amp DP Switch
Supply and fixing of following modular switch socket on the existing modular plate & switch box including connection but excluding modular plate and Modular box etc as required. 20 Amp Socket Outlet
Supply and fixing of universal shaver socket unit (vertical) with dual voltage sockets (230 Volts & 110 Volts), inbuilt Isolation transformer with safety overload protection with reset feature, auotmatic switch ON/OFF on inserting / removal of plug, indicating light for power ON status with safety shutters complete with Modular base and cover plate and GI Box.
Supplying and fixing following way, Vertical type TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with tinned copper bus bar, neutral link, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) i) 12 way (4 + 36), Double door
ii) 8 way (4 + 24), Double door
iii) 6 way (4 + 18), Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) i) 16 way, Double door
ii) 12 way, Double door
iii) 8 way, Double door
iv) 6 way, Double door
Supplying and fixing following rating, double pole, 240 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. i) 40A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. ii) 40 Amps
iii) 63 Amps
Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. i) 40 Amps
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. i) 100 mm width X 50 mm depth X 1.6 mm thickness
ii) 150 mm width X 50 mm depth X 1.6 mm thickness
iii) 300 mm width X 50 mm depth X 1.6 mm thickness
iv) 450 mm width X 50 mm depth X 2.0 mm thickness
v) 600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. i) 100 mm width X 50 mm depth X 1.6 mm thickness
ii) 150 mm width X 50 mm depth X 1.6 mm thickness
iii) 300 mm width X 50 mm depth X 1.6 mm thickness
iv) 450 mm width X 50 mm depth X 2.0 mm thickness
v) 600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. i)100 mm width X 50 mm depth X 1.6 mm thickness
ii) 150 mm width X 50 mm depth X 1.6 mm thickness
iii) 300 mm width X 50 mm depth X 1.6 mm thickness
iv) 450 mm width X 50 mm depth X 2.0 mm thickness
v) 600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. i) 100 mm width X 50 mm depth X 1.6 mm thickness
ii) 150 mm width X 50 mm depth X 1.6 mm thickness
iii) 300 mm width X 50 mm depth X 1.6 mm thickness
iv) 450 mm width X 50 mm depth X 2.0 mm thickness
v) 600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" (galvanisation not less than 50 microns) with perforation not more than17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. i) 100 mm width X 50 mm depth X 1.6 mm thickness
ii) 150 mm width X 50 mm depth X 1.6 mm thickness
iii) 300 mm width X 50 mm depth X 1.6 mm thickness
iv) 450 mm width X 50 mm depth X 2.0 mm thickness
v) 600 mm width X 50 mm depth X 2.0 mm thickness
Supply of following sizes complete with all accessories including junction box with 3 mm thick cover plate,neoprene gasket in joints ,cutting the floor and jamming the raceway with all necessary hardware (including civil works) as required. i) 65 x 38 x 1.6mm
ii) 100 x 38 x 1.6mm
iii) 200 x 38 x 1.6 mm
iv) 300 x 38 x 1.6mm
COMPRESSED CABLE TRANSIT SYSTEM Supplying, fabricating, laying and connecting the following stainless steel 4hr fire rated compressed cable transit system as per following specificaion: a) The Compressed cable transits system should have been tested for water tightness-6 Bar pressure, gas tightness-4 Bar pressure, Blast Load-3 Psi minimum as per 163, Should have been tested for Fire protection of 4 hour if the transformer is placed with in the Building otherwise should have been tested for EI120 for the multiple window frames as per standard BS476. b) Supplier needs to submit the Fire certification of at least EI120 for multiple window frame to justify the entry of multiple cable from a single transit point when travel from multiple tier cable trays. c) The Compressed cable transit system should have been tested for IP68 from a recognised international agency as per standard IEC 60529. d) The compressed cable sealing system should have been tested for protection of entry of Rodents. e) The module used for the Compressed cable transit system should be made of super resistant halogen free EPDM with low smoke index-F1 Classification as per NF16-101 & NF16-102, Heat Radiation test in compliance with M2/M1 classification, UV Ageing Test as per ISO-4892-2:2006 & ISO-815-1:2008, Oxygen Index Test as per ASTM D 2863-00. f) Stay plates required to be fitted between each layer of module should be of stainless steel AISI316. g) Compression wedge required to finally seal the complete system should be made up of super resistant halogen free EPDM with similar test parameters of modules and hardware of stainless Steel AISI 316. h) Compressed cable transit system should be calculated based on the number of cables and on the basis of outer diameter of cables and the transit calculated from the manufacturer transit planning software in square meter. i) EM/Manufacturer should have presence of more than 25 years in India or in rest of the world part with at least installation reference in India or in rest of world. j) Owner/ EPC contractor/End user/End client needs to provide the data of cables with cable count and future spare capacity, according to details manufacturer can do the calculation of area of transit system Make: MCT Brattberg / BST / Hawke Compressed cable system module must have facility to accommodate variation in diameter of cable with minimum 10 mm in below sized module. 20 Sized Module : Range Start From 4.0 mm – Min to 14 mm range or higher 30 Sized Module : Range Start From 11.0 mm – Min to 21 mm range or higher 60 Sized Module : Range Start From 32 mm – Min to 42 mm range or higher 90 Sized Module : Range Start From 49.5 mm – Min to 59.5 mm range or higher 120 Sized Module :Range Start From 71.5 mm – Min to 81.5 mm range or higher Packing space of Each Window 1 Square Feet and sealing cable diameter with following configuration: 1). 3.5 - 15.0 mm = 144 nos 2). 11.0 - 24.0 mm = 64 nos 3). 21.0 - 35.0 mm = 36 nos 4). 32.0 - 54.0 mm = 16 nos 5). 49.5 - 71.5 mm - 04 nos & 11.0 - 24.0 mm = 16 nos 6). 71.5 - 101.5 mm = 04 nos (Any one configuration to be consider among above 6)
MV CABLE Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. i) Upto 35 sq. mm
ii) Above 35 sq. mm and upto 95 sq. mm
iii) Above 95 sq. mm and upto 185 sq. mm
iv) Above 185 sq. mm and upto 400 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required. i) Upto 35 sq. mm
ii) Above 35 sq. mm and upto 95 sq. mm
iii) Above 95 sq. mm and upto 185 sq. mm
iv) Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. i) Upto 35 sq. mm
ii) Above 35 sq. mm and upto 95 sq. mm
iii) Above 95 sq. mm and upto 185 sq. mm
iv) Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. i) Upto 35 sq. mm
ii) Above 35 sq. mm and upto 95 sq. mm
iii) Above 95 sq. mm and upto 185 sq. mm
iv) Above 185 sq. mm and upto 400 sq. mm
Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. i) 3½ X 300 sq. mm (70 mm)
ii) 3½ X 240 sq. mm (62 mm)
iii) 3½ X 185 sq. mm (57 mm)
iv) 3½ X 150 sq. mm (50 mm)
v) 3½ X 120 sq. mm (45 mm)
vi) 3½ X 95 sq. mm (45 mm)
vii) 3½ X 70 sq. mm (38 mm)
viii) 3½ X 50 sq. mm (35 mm)
ix) 3½ X 35 sq. mm (32mm)
x) 4 X 25 sq. mm (28mm)
xi) 4 X 16 sq. mm (28mm)
xii) 4 X 10 sq. mm (25 mm)
xiii) 2 X 10 sq. mm (19 mm)
xiv) 2 X 6 sq. mm (19 mm)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. i) 120 mm dia (OD-120 mm & ID-103 mm nominal)
ii) 200 mm dia (OD-200 mm & ID-175 mm nominal)
Supply of following size of 1.1KV grade multicore aluminium conductor XLPE insulated PVC sheathed armoured power cable as per IS: 7098 (Part-1) 1988 complete as required. 3.5 core, 300 Sq.mm.
3.5 core, 240 Sq.mm.
3.5 core, 185 Sq.mm.
3.5 core, 150 Sq.mm.
3.5 core, 120 Sq.mm.
3.5 core, 95 Sq.mm.
3.5 core, 70 Sq.mm.
3.5 core, 50 Sq.mm.
3.5 core, 35 Sq.mm.
4 core, 25 Sq.mm.
4 core, 16 Sq.mm.
4 core, 10 Sq.mm.
2 Core 10 Sq.mm.
2 Core 6 Sq.mm.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supply, Installation, Testing & Commissioning of Surface/recess type LED (direct/indirect) of 595 x 595 mm size with aesthetically designed extruded aluminium housing & injection molded PC component diffuser with efficacy better than 120 Lumen/watt (minimum total lumen delivered package 3300), with CCT=3000/4000/5000 K,PF>0.95,THD<10% & with Driver having efficiency >85% .Service life of 50,000 hrs @ L 70 etc complete as required. (Driver complaince IEC 62384,IEC 61547,IEC 61347-2- 13,EMI-CISPR15) OR equivalent including making suitable arrengement for fixing on wall/ceiling & connection with 3x1.5 Sq.mm. PVC insulated FRLS PVC sheathed copper conductor in flexible GI conduit etc. as required.
Supply, Installation, Testing & Commissioning of LEDrecessed linear light fitting (1150-1200mm length and width 100- 125mm) for making continous linear arrangement including cascading kit etc with aluminium extrusion /CRCA housing CCT 4000- 5000k with system lumen output better than 3100 lumens and system efficacy better than 120 Lumens/watts ,driver efficiency better than 90%,PF better than 0.98, Reverse Polarity and Surge Protection upto 3 kV ,THD less than 5%, CRI better than 80 percent Service Life 50000 Hr@ LM70. OR equivalent including making suitable arrengement for fixing on wall/ceiling & connection with 3x1.5 Sq.mm. PVC insulated FRLS PVC sheathed copper conductor in flexible GI conduit etc. as required.
Supply, Installation, Testing & Commissioning of Surface/recess type LED downlighter neutral white (4000 K) with LED having pressure die cast aluminium hang body having high efficiencydiffuser with more than 85% transmittance with rated life of L-70 @ 50000 hrs having system lumen output better than 1150 lumens and efficacy better than 100 lumen/ watt(fixture design for meeting LG-7 Guideline) with CRI>80, Reverse Polarity and Surge Protection upto 3kV& Driver efficiency> 90%,PF>0.98,THD <5% (Driver complaince IEC 62384,IEC 61547,IEC 61347-2-13,EMI-CISPR15) etc.OR equivalent including making suitable arrengement for fixing on wall/ceiling & connection with 3x1.5 Sq.mm. PVC insulated FRLS PVC sheathed copper conductor in flexible GI conduit etc. as required.
Supply, Installation, Testing & Commissioning of LED Intelligent Batten Fixture with Body made up of Extruded Aluminium Housing and having In gress Protection of IP20 having LumenEfficiency>100lpw with Inbuilt Protection against Short Circuit,Miswiring, Over Voltage, Reverse Polarity and Surge Protection upto 3 kV, THD< 5%, UGR<19, CRI>80. The Length of the Fixture should be 1200mm with Avg Life of FIxture 50,000 @ L70. The Fixture should have inbuilt Motion Sensor along with RF and is Equipped with Remote Brightness Control, Dimming ON/OFF.
provide and install Red/ Green LED Laser etched emergency exit signages double/single sided pendant type made out of powder coated MS housing and etched acrylic sheet indicator with reflective light souce > 2W LED, Emergency Backup of minimum 4 hours, 6V 3.2 AH SMF/ SLA battery, SMPS Power supply suitable for operation on 230 AV 50 Hz AC supply as per the requirement at all prominent locations to guide the way out of the building to the building users in case of fire
Supply, Installation, Testing & Commissioning of LED Step-Light neutral white (4000 K) with LED having highefficiency Polycarbonate Diffuser & Integral Type Driver having systemlumen output 40Lmn. or better, withCRI>75, CCT 4000, IP 67, Class I maintenance free including making suitable arrangement for fixingcomplete with connection, testing and commissiong etc. as reqd. at site. OR equivalent including making suitable arrengement for fixing on wall/ceiling & connection with 3x1.5 Sq.mm. PVC insulated FRLS PVC sheathed copper conductor in flexible GI conduit etc. as required.
Supply, Installation, Testing & Commissioning of Neutral white(4000 K) LED Strip having Light output of 1000 Lumensper metre and system efficacy better than 65 Lumens per Watt with driver OR equivalent including making suitable arrengement for fixing on wall/ceiling & connection with 3x1.5 Sq.mm. PVC insulated FRLS PVC sheathed copper conductor in flexible GI conduit etc. as required.
Supply, erection, testing and commissioing of LED Aviation obstruction Light integral in aluminium housing with polycarbonate enclosure with LED's suitable for 230 V AC complete. as required. LED Aviation Light shall be as per BIS Standard.
Supply, Installation, Testing & Commissioning of 24V Surface Mount Linear fixture for wall washing and grazing application. The length of the fixture should be around 500mm. The housing should be made of extruded anodized aluminium. The protection rating of the fixture should be of IP65. Delivered lumens should be more than 1000 lumens. Luminous efficacy of the fixture should be more than 110 lm/W. The fixture should have wide elliptical beam distribution around 30˚ X 60˚. CCT of the fixture should be2700K or 3000K or as per requirement of the architect. Color Rendering Capability of the fixture should be more than 80. Fixture dimension should be around 500mm length X 50mm width X 95mm height and Location Entrance Gate & Bus Stop. Equivalent : Heper,Es System, Litolux
Supply, Installation, Testing and Commissioning of1200/1400 mm sweep BLDC ceiling fan providing minimum air delivery of 270 Cu Mtr/Minute with power consumption not more than 42 watts at the speed of 270 RPM,service value greater than 7, complete in all respect Powder coated Aluminium die cast body & blades(minimum 1 mm thick aluminium leaf), Power factor not less than 0.90 including providing 6 key remote alongwith necessary down rod of standard length (upto 30cms) complete as required. 1200 mm Sweep (BLDC Fan)
Supply of following sizes of Havey duty Exhaust fan with Louver suitable for operation on single phase 230 Volt AC 50 Hz supply complete with all fixing accessories as required. 300 mm Sweep (900 RPM)
Supply, installation, testing and commissioning of cabin fans of 1350RM made of high quality engineering plastic complete with all accessories as required in the following sizes :-400 mm Sweep.
Supply, Installation, Testing Commissioing of Sine Wave INVERTER, fully digital type and shall be based on PWM technique with following key features – Wide input voltage range 230V - 20% + 15 % and wide frequency 50Hz + 10%. Three Phase input / Three Phase output. INVERTER shall be static without any moving parts. Input supply shall be Three phase, Four wire system. PWM technique shall be used for producing AC output from DC input. Efficiency of the Inverter shall be greater than 85%. Output wave form shall be pure sine Wave with harmonic distortion less than 3%. Inverter shall be suitable for maximum ambient temperature of 60°c and acoustic noise at 1 Mtr shall be less then 55dB. Inverter shall have minimum of IP20 protection. The Inverter shall be complete with 90 minutes power backup on full load. Battery shall be sealed maintenance free type with suitable rack and connectors. 2.0 KVA
Supply testing & commissioning of 2x 40KVA/40KW Online in PRS mode with 3 phase AC input and 3 phase AC output with DSP Controlled microprocessor based technology with external SMF Battery Bank for minimum 30 minutes backup with MS Rack & accessories ( min. VAH required for battery bank =30200 VAH with each UPS ) ,Ups shoil be BMS Comaptible,The UPS should be with 3 level IGBT Based Inverter & IGBT based Rectifier Technology and with touch screen LCD/LED display for monitoring of its status.Both the UPS should be with Inbuilt Galvanic Isolation transformer of same OEM make of same rating of UPS at input side . Both the UPS should have individual battery bank of minimum 30200VAH and UPS should operate in PRS mode with 50% load sharing basis.
Supply testing & commissioning of 2x 60KVA/60KW Online in PRS mode with 3 phase AC input and 3 phase AC output with DSP Controlled microprocessor based technology with external SMF Battery Bank for minimum 30 minutes backup with MS Rack & accessories ( min. VAH required for battery bank =46800 VAH with each UPS ) ,Ups shoil be BMS Comaptible,The UPS should be with 3 level IGBT Based Inverter & IGBT based Rectifier Technology and with touch screen LCD/LED display for monitoring of its status.Both the UPS should be with Inbuilt Galvanic Isolation transformer of same OEM make of same rating of UPS at input side . Both the UPS should have individual battery bank of minimum 46800VAH and UPS should operate in PRS mode with 50% load sharing basis.
Supply & fixing of Rubber hand gloves 11 KV Tested.
Supply & fixing of glass framed shock treatment chart both in Hindi & English for treating person suffering due to electric shock mounted on wall hooks.
Providing & fixing of Carbon dioxide (CO2) type fire extinguishers conforming to IS 2878-1976 and cylinder fully charged of 4.5 Kg capacity hanged on wall with bracket component as required.
Supply and fixing safety instruction chart in word duly framed with 5mm thick glass required. (Approx Front area 1.20 sq.mt.)
Providing of set of 4 Nos. 9.5 Litre capacity GI bucket painted in post office red colour with prior coat of red - oxide paint and written with white paint 'Fire' and mounted on MS angle iron frame with bracket of appropriate size and capacity including filling sand etc.
First Aid box as approved by St. John Ambulance Brigade / Indian red Cross conforming to IS 2217 - 1963
Supply & fixing of fire retardant/ extinguishing Electrical insulated synthatic mat of 2.0 mm thick +/- 10% confirming to BIS: DOC NO. ET-02 (5440) meeting requirments of IS: 15652 :2006 (with upto date amendment), suitable for all voltages not exceeding 3.3 KV and having minimum width of 1000 mm +/- 20mm and including supply of required quantity of adhensive/ compound and fixing the same at size as per site requirments.
Supply & fixing of fire retardant/ extinguishing Electrical insulated synthatic mat of minimum 3.0 mm thick +/- 10% confirming to BIS: DOC NO. ET-02 (5440) meeting requirments of IS: 15652 :2006 (with upto date amendment),, suitable for all voltages not exceeding 33 KV and having minimum width of 1000 mm +/- 20mm and including supply of required quantity of adhensive/ compound and fixing the same at size as per site requirments.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supply and fixing of following sizes of steel conduit alongwith the accessories in surface/recess including painting in case of surface conduit or cutting the wall and making good the same incase of recessed conduit as required. 32mm dia
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
Supplying, installation, testing & commissioning of intelligent analog addressable Multicriteria smoke detector complete with mounting base complete as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of intelligent addressable smoke detector with rate of rise cum fixed tempreature thermistor complete with base as required.
Supplying, installation, testing & commissioning of addressable fire control module complete as required.
Supplying, installation, testing & commissioning of addressable phone control module/ Monitor Module complete as required.
Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections with remote test features etc complete as required.
Supplying, installation, testing & commissioning of intelligent addressable heat detector including suitable Photo detector complete with base as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.
Supplying, installation, testing & commissioning of intelligent interface unit BACnet/ Modbus protocol i.e. Supplying communication links between building management system and fire alarm control panel complete as required.
Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
Supplying, installation, testing & commissioning of ceiling/wall mounted loud speaker, 3/1.5 Watt in ABS enclosure complete as required.
Supplying, installation, testing & commissioning of digital audio amplifier 500 Watts x 2 channel, 25V rms operating at 240 Volt AC Supply complete as required.
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
Supplying, installation, testing & commissioning of 3Mpx Indoor dome 2048 x 1536 at 30fps, Autofocus Motorized remote zoom lens 2.8 - 8 mm, H.265/H.264 compression, 40 mtr Adaptive IR, 120dB . Minimum Illuminator @F1.4 0.13 lux color; 0.01 lux Mono, 3D noise filtering, Bi directional Full Duplex Audio, inbuilt mic, 1 Alarm In, 1 Alarm out, 3 independant stream, 8nos of configurable privacy mask, Supported protocol - TCP/IP, Ipv4 & IPv6,UDP/IP, DNS, DDNS,ARP, ICMP, IGMP, RTCP, SFTP, SIP, TLS/TTLS, ARP.802.1x (EAP-MD5, EAP-TLS, EAP-TTLS, EAP-PEAP and EAP-FAST). Edge based analytics -Object Counting, Adaptive Motion, Object Removal, Motion Detection, Camera Sabotage, Audio Detection, and Directional Motion. Camera shall features of Corridor mode, Mirror mode, having SD card provision of 128 GB, Operating temperature -10 to +50 deg C,IP64 ,IK10,Works on PoE+,ONVIF profile S,G & T,Cybersecrutiy Cert:UL/NDAA, CE - EN 55032 (Class A), EN 50130-4, EN 60950-1,FCC (Class A) - 47 CFR Part 15,UL and cUL Listed - UL 60950-1, CAN/CSA-C22.2 No. 60950-1-07, BIS certified.to ruggedized performace camera should meet Shock & Vibration Certifcation:IEC 60068:2-6 and 2-27 The Camera to be provided by OEM should not be complying to GB28181, GB/T28181-2011 standards and there should be no option to activate or deactivate GB/T 28181 standards in the camera web page/Settings.( Make: Axis/Pelco/Avigilon/Mobotix)
Supplying, installation, testing & commissioning of 3Mpx Indoor dome 2048 x 1536 at 30fps, Autofocus Motorized remote zoom lens 2.8 - 8 mm, H.265/H.264 compression, 40 mtr Adaptive IR, 120dB . Minimum Illuminator @F1.4 0.13 lux color; 0.01 lux Mono, 3D noise filtering, Bi directional Full Duplex Audio, inbuilt mic, 1 Alarm In, 1 Alarm out, 3 independant stream, 8nos of configurable privacy mask, Supported protocol - TCP/IP, Ipv4 & IPv6,UDP/IP, DNS, DDNS,ARP, ICMP, IGMP, RTCP, SFTP, SIP, TLS/TTLS, ARP.802.1x (EAP-MD5, EAP-TLS, EAP-TTLS, EAP-PEAP and EAP-FAST). Edge based analytics -Object Counting, Adaptive Motion, Object Removal, Motion Detection, Camera Sabotage, Audio Detection, and Directional Motion. Camera shall features of Corridor mode, Mirror mode, having SD card provision of 128 GB, Operating temperature -10 to +50 deg C,IP64 ,IK10,Works on PoE+,ONVIF profile S,G & T,Cybersecrutiy Cert:UL/NDAA, CE - EN 55032 (Class A), EN 50130-4, EN 60950-1,FCC (Class A) - 47 CFR Part 15,UL and cUL Listed - UL 60950-1, CAN/CSA-C22.2 No. 60950-1-07, BIS certified.to ruggedized performace camera should meet Shock & Vibration Certifcation:IEC 60068:2-6 and 2-27 The Camera to be provided by OEM should not be complying to GB28181, GB/T28181-2011 standards and there should be no option to activate or deactivate GB/T 28181 standards in the camera web page/Settings.( Make: Axis/Pelco/Avigilon/Mobotix)
Supply, Installation, Testing & Commissioing of 1/2.8", 2Mpx IR PTZ dome 1920 x 1080 at 60fps, Focal length 4.5 - 135mm, Horizontal angle of view: 58.3° (wide) ~ 2.34° (tele); 150mtr Adaptive IR, 100dB WDR,0.1 lux at color, Shutter range: 1 ~ 1/10,000 sec,Electronic image stablization, Ege based analytics - Motion Detection, Camera Sabotage, BLC, protocol support -IPv4 & Ipv6,802.1x (EAP), TLS1.2, ARP, ICMP, IGMP, DNS, DHCP, TCP/IP. Pan 360deg continuous, Tilt range: +15 to -90deg, Pan preset speed: 300°/sec; Tilt preset speed: 145°/sec, 256presets, having SD card provision of 2TB, Aluminium construction, 16 configurable pivacy masks,Operating temperature -40 to +60deg C, IP66, Type 4X Certificaiton, IK10 Enclosure, Works on (802.3bt), 24 VAC & 48 VDC, ONVIF profile S,G, & T, UL, CE, FCC, BIS certified. With require accessories wall mount, pole bracket etc.. The Camera to be provided by OEM should not be complying to GB28181, GB/T28181-2011 standards and there should be no option to activate or deactivate GB/T 28181 standards in the camera web page/Settings.( Make: Axis/Pelco/Avigilon/Mobotix
Supply, installation, testing and commissioning 12 volt 2 Amp Power Adaptor - 12 volt DC with SMPS Power Supply
Supply, installation, testing and commissioning Redundant IP PBX based on IP at core with hot standby configuration and geographical redundancy support , Each System should be expandable up to 15000 Lines.System should support Busy Hour Call Completion of 300,000 calls.The system will be Industry Standard servers based and it should support SIP, traditional TDM or mixed IP-TDM or full 100% IP configurations
Supply, installation, testing and commissioning 128 x 64 B&W graphical display with Backlight, 2-port Gigabit Ethernet Switch, Power over Ethernet class 1 for low power consumption, 6 Softkeys, alpha numeric Keyboard,Navigator: 4-way navigation, OK, cancel keys, Programmable keys, Lighted keys and notifications (Incoming call, message, audio control, programmable keys),Wideband G722, G711 (A-law and Mu-law), G729 AB, voice activity detection (VAD),2 SIP accounts,Phone operability from -5 to 45C
Supply, installation, testing and commissioning the WLAN solution shall propose a 802.11ac wave2 indoor dual-radio AP (2GHz, 5GHz) Access Point., The Access Point shall have integrated omnidirectional antennas. The Access Point shall support up to 16 SSIDs (8 per radio). The MTBF for the Access Point shall be at least 80+ Years.The Access Point shall offer up to 867Mbps throughput on the 5Ghz band and up to 400Mbps throughput on the 2.4GHz band.
Supply, Installation, Testing & Commissioing of Pole of 6 Mtr Height with concreate Base of camera - Pole Length should be 6 Mtr Height with all cameras accessories.
Supply, Installation, Testing & Commissioning of Wall Mount Side Integrated Economics Riveted - 04U - 550W - 450D - Single Fan Provision - Pastal Fine Tex.,ACCESSORIES INCLUED IN EACH RACK ARE:Single Fan For WallMount, Metal Cable Manager - 01U - Plastic Cable Loop's Mountable - Black Fine Tex. - Assembly, HARDWARE PKT 20SET,PDU 6A 4SKT SWT PLG A
Supply, Installation, Testing & Commissioning of ProTek Wall Mount - 06U - 600W - 500D - Double Fan Provision - Pastal Fine Tex.,DOUBLE FAN FOR WALLMOUNT,CABLE MNG PLOOP BT 1U A,HARDWARE PKT 20SET ,PDU 6A 6SKT SWT PLG A
Supply, Installation, Testing & Commissioning ofL2 switch with 8 x 1G Base T Port PoE+ with 2 x 1G SFP and 2 IG Base T port, The switch must be stackable upto 4 Units, Switching Capacity should be 40 Gbps or more with not less than 35 Mpps Throughput ,Switch should have 1GB Flash and 1GB RAM ,The switch must support minimum 16K MAC address entries and 4K VLAN with latency of less than < 4 µs
Supply , Installation,testing and commissioning of I/O with faceplate & Gang Box
Supply , Installation,testing and commissioning of Cat6 patch code 1 Mtr
Supply , Installation,testing and commissioning of Cat6 patch code 2 Mtr
Supply , Installation,testing and commissioning of Cat6 patch code 3 Mtr
Supplying and installation Testing and Commissioning of 24 core Fiber Cable - Single Mode
Supplying and installation of HDPE Pipe - 40 MM
Supplying and installation of Under ground Cable Laying with HDPE Pipe
Supply Installation Testing & Commissioning of SFP Module - 1000Base-LX Gigabit Ethernet optical transceiver SFP MSA). Supports single mode fiber over 1310nm wavelength nominal) with an LC connector. Typical reach of 10 Km on 9/125 m SMF.
Supply Installation Testing & Commissioning of L2 switch with 24 x 1G Base T Port PoE+ with 2 RJ45/SFP combo port and 2 x 1/10G SFP+ ,The switch must be stackable upto 4 Units , Switching Capacity should be 90 Gbps or more with not less than 135 Mpps Throughput ,Switch should have 1GB Flash and 1GB RAM, The switch must support minimum 16K MAC address entries and 4K VLAN with latency of less than < 4 µs , Switch shall conform to following standards
Supply, Installation testing and Commissioning of L2 switch with 24 x 1G Base T Port PoE+ with 2 RJ45/SFP combo port and 2 x 1/10G SFP+ with PoE Budget of 380W, The switch must be stackable upto 4 Units,SFP Should be from the same OEM .Switching Capacity should be 128 Gbps or more with not less than 135 Mpps Throughput .
Supply , installation , testing and commissioning of Electric Power Cable 2* 1.5 Sq mm
Supply , installation , testing and commissioning of 3 Pin top(Plug)
Supply , installation , testing and commissioning of Power Board with 6 socket
Supply installation Testing and Commissioing of Video Management Recording servers .it should supports upto 128 cameras for future upgradation .It should have Intel® Xeon® Silver 4210 or better with 16 GB DDR4 ECC RAM or better. It should run on Windows® 10 IoT Enterprise 64-bit (LTSB) or latest.It should have M2. SSD 2 x 480 GB for operating system.Shall support Dynamic Host Communication Protocol ( DHCP ) and Network Time Syncronisation Protocol ( NTP ) functionality. It shall have Mapping function. It should support RAID6 .It should have dual power Supply.It should have in built plugins to integrate third party systems. It shall have 12 HDD slots . Each Box should have Thoughput should be 450 Mbps. ,*Video Outputs- 4x Mini Display port 1.4 ,*VMS Should support ONVIF S,G & T ,Should have NVIDIA Quadro P620 (2 GB memory) ,Should have 2xGigabit Ethernet (1000Base-T) ports ( Make: Axis/Pelco/Avigilon/Mobotix) Supply installation Testing and Commissioing of Video Management Softwarwe - VMS should have smart motion Search for server side motion detection and quick retrieval of events, *Edge Storage Auto Gap Fill functionality detects when a gap in local camera recording occurs, and automatically downloads video and audio (if present) to fill the gap ,*web based client allows viewing and exporting video without installing any softwar, *Imports users and roles from existing LDAP servers to reduce administrative overhead, and enables single sign-on (SSO), *Capable of listening for ASCII commands on a serial and Ethernet port simultaneously ,*Supports shared displays so operators can send video to surveillance personnel who need it most ,*Check on VMS and camera health using SNMP, *Supports IPv4 and IPv6 cameras, *Enables and supports Risk Management Framework (RMF) ,*TLS-based encryption over HTTPS ,*Extensible through mapping and plugins, including video information overlays and license plate recognition ,*should include feature, which is capable of polling for alarms from devices and performing specified actions when an alarm state change occurs *Incorporates FIPS 140-2 validated cryptographic modules.To ensure seamless deep integration VMS should be of same camera OEM ( Make: Axis/Pelco/Avigilon/Mobotix)
Supply , installation , testing and commissioning of Harddisk 8 TB - Hard disk should be surveillance 24*7 hour Oprated
Supply , installation , testing and commissioning of 55" LED TV- LED TV should be Professional with HDMI port
Supply , installation , testing and commissioning of 10KVA Online UPS (1+1)with 1 Hour Battery Backup
Supply , installation , testing and commissioning of 42 U Rack with all accessories -- Moducab Networking - 42U - 800W - 1000D - Pastal Fine Tex.ACCESSORIES INCLUED IN EACH RACK ARE:Moducab Front Glass Door - 42U - 800W - Cam Lock - Ventilation - Duscky Fine Tex. - Assembly, Moducab Rear Door - 42U - 800W - Cam Lock - Square Slot Ventilation - Duscky Fine Tex. - Assembly , Four Fan For Mcab/ProTek FS ,Monitor Tray - Ventilation - 495W - 700D - Pastal Fine Tex.- Assembly
Supply , installation , testing and commissioning of 24 port Switch with 4 SFP port
Supply , installation , testing and commissioning of SFP Module - 1000Base-LX Gigabit Ethernet optical transceiver SFP MSA). Supports single mode fiber over 1310nm wavelength nominal) with an LC connector. Typical reach of 10 Km on 9/125 m SMF.
Supply , installation , testing and commissioning of Distribution Swich - 28 port Single mode Gigabit Fiber Switch with 10 G uplink - tjhis cell has an external reference that cannot be shown or edited . Eidiiting this cell will remove the external refrences
Supply , installation , testing and commissioning of 24 Port Cat 6 Patch Panel - Universal mounting of all cabinets or enclosures, Panel: DC01 galvanised sheet steel, Operating temperature: -40°C to +70°C
Supply , installation , testing and commissioning of PTZ Controller - should control PTZ Camera for PN ,TilT , Zoom
Supply , installation , testing and commissioning of HDMI Cable 5 Mtr
Supply , installation , testing and commissioning of Client work Station
Supply , installation , testing and commissioning of Video Management Server
Supply , installation , testing and commissioning of Network Storage Device
Supply , installation , testing and commissioning of Network Storage Device
DG SET (380 KVA) - All Around Fencing is also required. The cost is to be consider in same items. Providing, Installing, Testing and Commissioning of 'Standard Type' Diesel Generating with Accoustic Enclosure set alongwith having Prime Power Rating of 380 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415V suitable for 50 Hz, 3 phase system and consisting of the followings: (Total of a to h).
Supply and fixing Exhuast piping for DG Set's with following sizes of MS pipes conforming to IS -3589 with bends, tees, reducers, fleixble connection etc. supplying & fixing of 150 mm thick Rock wool matrix (3x50 mm. thick) insulation of density 150 Kg per cubic metre on all sides of Exhaust pipe with chicken mesh wrapping and 22 SWG aluminium sheet cladding , suitable for outdoor installation, guide support, expansion joint, SS bellows complete as required and as per specification. 250 mm dia MS pipe (5.20 mm thick)
Fabrication, supply & erection of MS support duly painted for fixing of exhaust piping (Heavy Duty) and MS structure including Angle / chanels / flats / beam as per approved drawings for supporting of DG exhaust stack from ground. floor level and above terrace level complete in all respect.
Supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based Novec 1230 System for Transformer (Linear Pnuematic Heat Detection Tube Indirect Low pressure Protection System), consisting of the Mentioned components 10.0 Kg capacity NOVEC 1230, DLP Assembly with automatic valve, push in connector for tube, 10.0 Kg NOVEC 1230 gas, mounting bracket, End of Line adopter and low pressure switch for monitoring system activation.
Discharge Hose With Two nozzle Kit
2kg capacity Novec 1230, DLP Assembly with automatic valve, push in connector for tube, mounting bracket, End of Line adopter and low pressure switch for monitoring system activation.
4 Kg capacity NOVEC 1230, DLP Assembly with automatic valve, push in connector for tube, 4 Kg LB NOVEC 1230 gas, mounting bracket, End of Line adopter and low pressure switch for monitoring system activation.
Linear Pneumatic Heat detection tube with all necessary & supports
Master Control Unit with Audio Visual Alarm with wiring to make complete system operational . The control Panel should have provision for integration with fire Alarm /SCAD/BMS System.
Supplying,installation,testing and commissioning of 6 meter Height hot dipped galvanized pole for corrosion resistance - 60% more life at 20% higher cost continously tapered (bolt fixing type) octagonal Pole with top 70 mm dia and bottom 130 mm dia made of 3 mm thick H T sheet Steel conforming to grade S 355 complete with G I base plate of size 220 mm (L) X 220 mm (B) X 16 mm thickness welded at bottom of pole complete with 4 Nos 20 mm dia 600 mm long foundation bolts confroming to EN 8 grade, inbuilt / Vandal resistance, weathproof electrical junction box having terminal block, MCB etc mounted on bakelite sheet for looping in /looping out of cables, with flush door having locking arrangement, earthing arrangement (at atleast 0.5 m height) and mounted on RCC foundation of size 500 mm x 500 mm x 1200 mm in ground and 200 mm above ground level with foundation bolt duly embeded before casting and supply and embedding of suitable size HDPE pipe sleeve for cable entry. complete including erection of Pole complete in all respect as per specification as reqd.
Supplying,installation,testing and commissioning of Ornamental Poles 3Meters- Description Below 1) Design Standard EN40 2) Design criteria- 2.1) Basic Wind Speed: 169 kmph 2.2) Topography is considered as flat. 3) Materials. 3.1) Pole shaft: Steel tube grade YSt 240. 3.2) Base plate: A36/A572-50 or equivalent. 3.3) Anchor Bolts: EN8 Grade 4) Hot dip galvanised to ASTM A123, with minimum average GI coating of 65μm. 5) PU(Polyurethane) painted with avg. DFT of 70μm, using very high quality paint & primer. supply and embedding of suitable size HDPE pipe sleeve for cable entry. complete including erection of Pole complete in all respect as per specification as reqd.
Supply Installation , Testing & Commissioning of IP66 LED street light fitting having system lumen output not less than 7000, efficacy better than 110 lumens per watt and life expentency of 50000 burning hours@ L70, Power Factor > 0.90 & THD <20%, CRI better than 70,neutral white light and made of pressure die cast / extruded Aluminium housing with separate optics and control gear compartment, toughened glass protector, permanently sealed and a removable control gear plate, , mounting spigot suitable for horizontal mounting (Ø 32 – 42mm) with tilt flexibility of (+)(-) 10 degrees, suitable for operation on 230 V +/- 10 % single phase 50 Hz AC Supply , surge protection of 3KV and driver efficiency more than 85%(LED shall be of Cree/Lumileds/Nichia complete in all respect i/c connections etc as reqd.
Supply Installation , Testing & Commissioning of LED Post top luminaire, electrical Class I, with a Graphite grey painted high die cast aluminium body with specially profiled cooling fins for effective heat management, optical grade opal PC Diffuser ( IK 08 impact resistance), of IP 65 optical & Mid Watt SMD, suitable for vertical mounting of 60mm diameter. The luminaire shall have a CCT of 3000K and Colour Rendering Index (CRI) ≥80, a driver (efficiency ≥ 85%) with internal surge protection of 4/4 kV and external surge protection of 6/6 kV (in both Common & Differential Modes), Power Factor ≥0.95, a residual flux of 70% (L70) @ 50,000 hours. etc as reqd.
Supply, Installation, testing and commissioning of 1000mm long Single arm 60mm dia bracket of approved design and shape made up of MS metal with hot dip galvanised suitable for pole top of 70mm dia complete with fixing arrangement as required
Supply, Installation, testing and commissioning of 1000mm long Double arm 60mm dia bracket of approved design and shape made up of MS metal with hot dip galvanised suitable for pole top of 70mm dia complete with fixing arrangement as required
Supply of LED flood light fixture suitable for Surface / Wall type mounting with Epoxy powder coated die -cast aluminium housing with heat Sink, toughened glass, complete with inbuilt electronics driver, mounting bracket, 110 Lumen /watt efficacy, min 7000 Lumen output, THD<10%, P.F. >0.95, IP 65 rated as required
Design, manufacturing, testing at works, supply and delivery, receiving, unloading, storing, inspection, handling, assembling, installing in correct assigned position, effecting proper connections, testing and commissioning of following capacity passenger-lifts in Shaft of dimensions 2350 mm x 2300 mm (W x D) for minimum payload carrying capacity of 10 passenger/ 884 kg (Duplex Control) having a travel speed of 1.5 metre/ sec and travel height of 15 Mtrs. (approx.) with 4 Stops and Microprocessor based control suitable for operation on 415 V, 50 Hz, 3 phase A.C. electric supply complete as per specifications. (Ground - 3rd Floor) . with VVVF drive, full collective Triplex control on 415 V, 50 cy cles, 3 phase power complete in accordance with specifications and drawings as required with Car, Car Door & Hoistway Door in stainless steel hairline finish, inclusive of built in ARD and as per specification including cat 6 wiring for CCTV. 12 Passenger Lift
Design, manufacturing, testing at works, supply and delivery, receiving, unloading, storing, inspection, handling, assembling, installing in correct assigned position, effecting proper connections, testing and commissioning of following capacity passenger-lifts in Shaft of dimensions 2500 mm x 2100 mm (W x D) for minimum payload carrying capacity of 16 passenger/ 1000 kg (Simplex Control) having a travel speed of 1.5 metre/ sec and travel height of 15 Mtrs. (approx.) with 4 Stops and Microprocessor based control suitable for operation on 415 V, 50 Hz, 3 phase A.C. electric supply complete as per specifications. (Ground to 3rd Floor) . with VVVF drive, full collective Triplex control on 415 V, 50 cy cles, 3 phase power complete in accordance with specifications and drawings as required with Car, Car Door & Hoistway Door in stainless steel hairline finish, inclusive of built in ARD and as per specification including cat 6 wiring for CCTV. 16 Passenger Lift
Design, manufacturing, testing at works, supply and delivery, receiving, unloading, storing, inspection, handling, assembling, installing in correct assigned position, effecting proper connections, testing and commissioning of following capacity passenger-lifts in Shaft of dimensions 2600 mm x 1900 mm (W x D) for minimum payload carrying capacity of 14 passenger/ 884 kg (Triplex Control) having a travel speed of 1.5 metre/ sec and travel height of 15 Mtrs. (approx.) with 4 Stops and Microprocessor based control suitable for operation on 415 V, 50 Hz, 3 phase A.C. electric supply complete as per specifications. (Ground to 3rd Floor) . with VVVF drive, full collective Triplex control on 415 V, 50 cy cles, 3 phase power complete in accordance with specifications and drawings as required with Car, Car Door & Hoistway Door in stainless steel hairline finish, inclusive of built in ARD and as per specification including cat 6 wiring for CCTV. 14 Passenger Lift
Supply, installation, testing and commissioning of Tabletop Video Conference System for Microsoft Teams Room with BYOD. Should be Native Microsoft Teams room device. Should have Mini PC and touchpanel Should have Windows 10 IOT Edition OS or equivalent, device with andorid platfrom should not be quoted. Should support mode swap between Native Teams and Native zoom app. Should have a minimum of 10" Touch screen or bigger Should support minimum of 2x touch screen to be connected to the system for ease of use. Should use maximum of 1x IP. For systems requiring more than one IP a managed ethernet switch should be supplied along with the UC unit. Should support minimum of 2x displays to be connected to view farend and presentation on different displays Should display minimum of 3x one-touch joins on the touch panel Should support wired presentation via HDMI and USBC or an external adapter should be supplied. Should support BYOD feature to connect any laptop and make a thirdparty call using the room pheriperals - camera, mic and speaker. should natively include a transmiter and receiver for HDMI and USBC presentation or an external transmitter receiver should be supplied. Should support additional camera to be connected for whiteboard. Should be able to create camera preset and control the camera via the touchpanel. Should support minimum 1080P call quality or better Should support call control and room device control on the same touch panel. Should support cloud management services, to maintian, manage and monitor these device from IT room. Make: Crestron / Poly / Cisco
Supply, installation, testing and commissioning of 3channel Amplifier. Should have minimum 3x Balanced or unbalanced analog line-level input or more Should have minimum 3x speaker output or more Should have inbuilt support for 4/8 Ohm Impedance and 70/100Volt direct coupled or an external transformer taps should be supplied. Should be Bridgable with the adjoining channel should support minimum ouptut of 3x210W watts per channel at 4-8Ohms or 70Volts. Should support frequency response of 20 Hz to 20 kHz ±0.5 dB at 1 Watt or better Should have individual gain control for each output channel. Should feature inbuilt Over Temperature circuit to Protect the amplifier power supply and each channel against overheating or excessive temperature; Should have inbuilt power adapter or an external power supply should be supplied. Should have LED indicators for fault identification. Should be controlable via the central control system and display the amplifier health status on the touch panel.Should be Rack- mountable with front rack ears and rear support brackets provided or additional mounting accessories should be supplied. Should be ENERGY STAR, ErP (1275/2008/EC), UL® 62368 compliant. Make : Crestron / Shure / QSC
SITC of Two-Way 6.5" Coaxial Ceiling Loudspeaker consist of a 6.5 inch high tech cone driver and a 0.75 inch soft-dome liquid cooled tweeter, paintable baffle made of UV resistant, with a pre-attached blind-mount back can for quick and easy installation. Frequency Response : 62Hz to 20kHz (-10 dB); Power capacity: 100W Continuous Program Power and 50W Continuous Pink Noise @ 8 ohm; transformer taps : 30W, 15 W, 7.5 W@ 70V or 100V (plus 3.8 W @ 70V only); Coverage : 110° conical coverage; Sensitivity: 91dB; Maximum SPL : 116 dB peak @low-impedance, 106 dB (top 70V/100V tap). Safety: UL1480, UL2043, NFPA90 & NFPA70;
SITC of Two way Compact 5.25” wall/surface mounted Loudspeaker consist of 5.25 inch polypropylene coated woofer, 0.75 inch titanium coated horn-loaded tweeter includes invisiball aimable wall-mounting hardware. Should have Frequency Range (-10 dB) : 70 Hz – 23 kHz; Power Capacity : 200 Watts Continuous Program Power, 100 Watts Continuous Pink Noise @ 8ohms also support transfer 70V & 100V lines having transformer taps 70V: 60W, 30W, 15W, 7.5W taps , 100V: 60W, 30W, 15W taps; Coverage: 100° x 100°; Nominal Sensitivity : 87 dB SPL, 1W @ 1 m; Maximum SPL @ 1m 113 dB continuous peak pink noise; Nominal Impedance: 8 ohms; Outdoor compatible Exceeds Mil Spec 810 for humidity, salt spray, temperature & UV. IEC 529 IP-X4 splashproof rating. Make: JBL.Martin Audio/Lacquostics
Supply, installation, testing and commissioning of surface mounted USB over Ethernet Extender over Twisted Pair, Should be capable of communicating over an ethernet network or point-to point over Cat5e. Should be USB 1.1 and 2.0 compatible including isochronous devices Should Transports USB over Ethernet or CAT5e at speeds up to 480 Mbps or better Should support extension and routing of any USB 1.1 or 2.0 device across an Ethernet network Should support extension and routing of any USB 1.1 or 2.0 device point-to-point over CAT5e Should be able to communicate with the central control system Should support USB 2.0 device port for connection to the USB host computer, media server, game console, annotator, codec, etc. Should have 1x USB Type B female port along with patchcable Should support length upto 330ft in point to point mode Should be supplied with mounting bracket. Make : Crestron / Extron / AMX
Supply, installation, testing and commissioning of A simple modular tabletop connectivity solution for conference tables and presentation lecterns. Should provides twelve module slots arranged in two rows of six. Should have a Universal Power Socket Should have a 1x USB A & 1x USB C ports for Charging Should have a provision of 4 Retractors for HDMI, MDP, CAT-6 Retractor cables each cable pulls out smoothly up to 5 ft Retractor should have a Push Buttons which can be used to control the devices through controller Retractor should able to communicate with the Control syste. MAke : Crestron / AMX / Extron
Supply, installation, testing and commissioning of surface mounted wireless Presentation system, should support secure wired and wireless presentation from laptops, smartphones, and tablet devices using the existing Wi-Fi® wireless network for BYOD connectivity. Should support Miracast, Should have 1xHDMI input or more, supporting resolution up to 1920x1080@60Hz (HD 1080p60), 4:4:4, 36bit color depth, Should have 1xHDMI output supporting single HD or 1920x1080@60Hz (HD 1080p60), 4:4:4, 36bit color depth, Should have 1xBidirectional RS232, 1xIR/one-way Serial port for controlling the connected display or an external control port expander should be provided. Should support minimum of Two simultanious device to be displayed on a single screen. Should have built-in native integration with Microsoft® Office 365® and Outlook® calendaring applications via Microsoft Exchange, for Displaying space availability, meeting details, and other messaging on the connected room display, or a suitable external room scheduling pamera, mic and speaker should natively include a trans
Supply, installation, testing and commissioning of 10.1" Room Scheduler with Light Bar. Should be minimum 10.1 in. widescreen active-matrix color display touch screen or better Should support minimum resolution of 1920 x 1200 WUXGA display or better Should support Brightness 400 nits (cd/m²) or better Should support contrast 1000:1 or better Should support viewing angle of ±80° horizontal, ±80° vertical or better Should support minimum RAM 2 GB LPDDR3 or better Should be Capacitive touch screen display Should support Built-in Bluetooth communication beacon Should support Wi-Fi Network conenctivity"&D70&" Should support IoT cloud based remote provisioning, monitoting and managing. Should support scheduling applications Should support direct integration with Exchange, Office 365 & G-Suit Should have built-in proximity sensor. Make : Crestron / AMX / Condeco
Supply, installation, testing and commissioning of 10.1" Room Scheduler with Light Bar. Should be minimum 10.1 in. widescreen active-matrix color display touch screen or better Should support minimum resolution of 1920 x 1200 WUXGA display or better Should support Brightness 400 nits (cd/m²) or better Should support contrast 1000:1 or better Should support viewing angle of ±80° horizontal, ±80° vertical or better Should support minimum RAM 2 GB LPDDR3 or better Should be Capacitive touch screen display Should support Built-in Bluetooth communication beacon Should support Wi-Fi Network conenctivity"&D70&" Should support IoT cloud based remote provisioning, monitoting and managing. Should support scheduling applications Should support direct integration with Exchange, Office 365 & G-Suit Should have built-in proximity sensor. Make : Crestron / AMX / Condeco
Supply, installation, testing and commissioning of DIN Rail mountable, High Voltage Relay array, Should have minimum of 8x channel of power switching with seperate input power for each channel Should support minimum of 10Amp per channel Should have Override input to bypass the control system in case of emergency Should have 8x Input port to connect rocker buttons or a separate input port unit should be supplied should support 120 to 240 Volt 50/60 Hz lighting and motor loads Should be 9DIN module or less Should be CE Compliant Should be able to communicate with the Central control system via 4wire bidirectional communication bus or any bi-directional protocol"&D70&" Should be able to install multiple Relay array units in a single communication bus and controlled by a single control system. Make : Crestron / AMX / Lutron
Supply, installation, testing and commissioning of keypad, Should have minimum of Five configurable buttons arranged in one column Should have engravable and Field-Replaceable Button Caps Should have built-in ambient light sensor Should support One RGB LED backlight per button to illuminate the button engraving Should Support adjustable brightness and RGB color mixing to allow any color or pure white across the full range of CCT values Should support settings for button feedback and day/night modes; adjustable blink feedback Should have 2x IO ports to connect any device that provide DC logic or 0-10VDC contact closure or an external input port should be supplied. Should be able to connect multiple keypad; All buttons in a multi-gang arrangement should align to form one continuous control surface. Should be able to communicate with the Central control system should be supplied with all the necessary accessories and faceplate. Should be able to install multiple keypads in a single communication bus and controlled by a single control system. Should be IC, FCC Part 15 Class B digital device compliant. Make : Crestron / AMX / Lutron
Supply, installation, testing and commissioning of Rack mounted Control processor, Should have onboard IR/serial, COM, I/O, relay, 4wire communication bus network, and high speed gigabit Ethernet control ports, Should support iPhone, iPad, and Android device control app. Should have onboard Native BACnet network/IP support or an external BACnet interface should be supplied. Should Support XPanel computer and web based control or an 10" touch panel with all accessories should be supplied. Should have onboard minimum of 2xRS-232, 1xRS-485, 8xRelay, 8xIR/one-way serial, 8xI/O ports or an external control port expander should be provided to match the minimum requirement. Should have a 4wire bi-directional communication bus to facliate communication with other devices of the same OEM. Should have onboard 2GB of SDRAM and 8GB Flash or more, Should support USB mass storage of minimum 1TB or more. Should Support SNMP V3 remote IT management support. Should be CE, IC, FCC Part 15 Class B digital device compliant. Make: Crestron/Extron/Amx
Supply, installation, testing and commissioning of Network based Occupancy Sensor. Dual-Technology Occupancy Sensor, PoE, 2,000 Sq Ft, ceiling-mounted occupancy sensor that features passive infrared (PIR) and ultrasonic (US) motion detection technology. It is designed for areas up to 2,000 square feet, making it great for use in large spaces such as auditoriums, warehouses, and building lobbies. Sensor and Control system should be of the same OEM. Make : Crestron / AMX / Lutron
Supply, installation, testing and commissioning of 06ft Male to Male high-speed Category 2 HDMI® patchcable. Should be minimum of 06 feet length or more Should have Male to Male HDMI connector Should support 4K60 4:4:4 video, 18 Gbps bandwidth Should be 24k gold-plated 19-pin Type A connectors or better Should be High-flex CL3-rated jacket or better Should be RoHS compliant. Make : Crestron / Extron / Lightware
Supply, installation, testing and commissioning of Ultra high-bandwidth Cat7a shielded twisted pair, Non-plenum cable. Should be minimum 1000 feet spool or more Should be 22 AWG solid copper conductor Should be Ultra high-bandwidth CAT7a shield twisted pair (S/FTP) cable Should enable lossless distribution of 4K and Ultra HD video signals at distances of 330 ft via Twistted pair or HDBaseT® should exceed HDMI specifications requiring less than one pixel error per billion Should have delay skew of ≤25 ns / 100 m or better should be Qualified for use with 10-Gigabit Ethernet data networks Should be Type CMR rated for riser and other non-plenum installation Should have S/FTP with four individually shielded twisted pairs, overall shield, and overall jacket Should be Type CMR, NEC Article 800, UL Subject 444, cUL, IEC 61156-5, ISO/IEC 11801, Category 7a. Make : Crestron / Extron / AMX
Supply, installation, testing and commissioning of Ultra high-bandwidth Cat7a shielded twisted pair cable Connector. Provides an ultra-high-performance shielded CAT6a RJ 45 plug. Exceeds Category 6A performance requirements. It should have minimum 20 nos of connectors Make : Crestron / Extron / AMX
Supply, Installation, Testing and Commissioning of DLP Laser Phosphor based projection system with 6000 ISO Lumens light output , Native 1920 x 1200 resolution , Contrast ratio(dynamic) 18,000:1 or better, 10-bit colour display or better,Full HD 3D ready,24/7 operation,Capability of Streaming of video and audio content from a compatible mobile device,Input support for 4K-UHD, 3840 x 2160. Inputs/Outputs Inputs: 1 x VGA in/out, , 2 x HDMI , 1 x HDBaseT, 3G-SDI in/out Controls: 3D sync in/out, RS232, Audio in/out stereo.Control: Crestron RoomView, AMX & RS232, Ceiling mount kit . along with a suitable lens for a screen size of 4m x 2.5m with throw distance 5m or less.Make: Barco/DPI/NEC
Supply,Installation,Testing & Commissioning of Motorised Tab Tension Projection Screen with tubular motor , screen size 10'(w) x 6'(h) , White matt seamless fabric , LVC Control, Wall / Ceiling mount bracket. Make: Talone/Cinema Works/Prima
Supply,Installation,Testing & Commissioning of Boundry Layer Microphone with element Electret condenser Polar Pattern Cardioid , Rated Impedance 120 Ω, Sensitivity -33 dB (1 kHz 0 dB=1 V/Pa) , Phantom Power 9 - 52 V DC , Frequency Response 35 Hz - 20 kHz Low Cut 100 Hz, -12 dB/oct , Output Connector XLR-3-12 Finish Body: Die-cast aluminum, black, mat finish . Make: Beyerdynamic/Sennheiser/Shure
Supply,Installation,Testing & Commissioning of Shielded Twisted Pair Cable , Conductor Metal: Solid Bare Copper with 23 AWG Color Code: Blue/ Grey ( or any combination) , Jacket Material: PVC UL94V-0 . Make : D-Link/Beldon/Polycab
Supply,Installation,Testing & Commissioning of Microphone Cable with high−quality shielded pair for routing balanced mono or unbalanced stereo mic stranded 20AWG tinned copper .Make : Polycab/Beldon/Gloster
Supply,Installation,Testing & Commissioning of Equipment Rack of Size 24 u , 600 mm (W) , 800 mm (D) with front door , Front door lockable with tinted glass / Fiber sheet , Rear door lockable , Top cover with cable entry provision , Fully vented with blowers , Castors with foot operated brakes , 19″ mounting angles at front and rear , 10 x 16amp sockets . Make : Panduit/Rittal/Dlink/Valrack
Supply, Installation, Testing and Commissioning of 48 x Gigabit Ethernet Ports , 2 x GbE/SFP Combo Ports , 192W Dedicated PoE Power , 74.41 Mpps Transfer Rate , 100 Gb/s Switching Capacity , 24 Mb Packet Buffer , IPv6 Support , Advanced Layer 3 Traffic Management , Builtin Two Fans. Make : Cisco / Netgear / Alcatel /Allied
SITC of Full HD PTZ Camera supporting1080p at 60 Frames per Second, minimum 12X Optical Zoom, min 100 Presets, , USB 3.0 & HDMI Out, RS232/422 Controls, -100° ~ +100° Panning angle, -30° ~ +30° Tilting angle , Minimum FoV 72 deg. OEM should be CE, RoHS & FCC Certified. Make: Sony/Lumens/Panasonic/Vaddio
Supplying, installing by suspension on ceiling/along the wall, testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos. aluminium bus bars having current density of 130 A/ sq. cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every meter, adopter box and copper flexible for joints, continuous earthing with 2 Nos. aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. 400 A, Isc = 25 kA for 1 second
630 A, Isc = 50 kA for 1 second
Supplying, installation, testing & commisioning of following capacity Plug In/ tap off box on the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with MCCB complete etc. as required125 A, FP Isc = 15 kA for 1 second
200 A, FP Isc = 25 kA for 1 second
Supplying, installation, testing & commisioning of following capacity End Feed Unit for the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with MCCB complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required 630 A, FP Isc = 50 kA for 1 second
Design, Manufacture, Supply, Installation, Testing, and Commissioning of Sandwich Busway 415 volts system Busduct, 4bar - 3P & 1N, Aluminum conductor with aluminium body /MS powder coated enclosure with 2 x 50 x 6 mm GI earth tapes continous runs throughout as earth, in accordance with (BSEN60439 – 1 & 2 (IEC 439 – 1 & 2) standard, BS5486-2 and AS 3439.2) latest as per specifications, suitable for 3ph 4wire 50HZ, of short circuit fault withstand capacity for 1 Sec as specified below. The bus duct suspension system shall be complete with steel rods, GI angle supports and dash fasteners etc. at required intervals for safe installation of bus ducts. Necessary flexible joints to be provided and thermal expansion as may be required. Straight Run Horizontal as welll as Vertical lengths (without provision of tapping). Vertical/Horizontal Bends. 1250 A 50kA SC for 1 sec (IP 65 : OUTDOOR TYPE) - F CLASS
800 A 50kA SC for 1 sec (IP 65 : OUTDOOR TYPE) - F CLASS
Supply, installation, testing & commissioning of MCCB in Sheet Steel enclosure made out of 2 mm thick CRCA sheet suitable for 3 phase 4 wire 50Hz AC system complete with four pole Moulded Case Circuit Breaker (ICS = 35KA) suitabel for incoming & outgoing termination including power coating etc. complete as per specification & as required. 400 Amp FP MCCB
160 Amp FP MCCB
125 Amp FP MCCB
63 Amp FP MCCB
Final testing & commissioning 300 KVAR Capacitor duty switched APFC panel, inteligent APFC controller, Capacitor firing modules, self current limiting coil complete with controls for automatic power factor improvement of capacitor bank(s) suitable for operation on 415 V, 50 Hz, AC supply & to maintain the P.F. upto 0.99 lagging.The panel shall be fabricated from CRCA sheet steel enclosure made out of 2mm sheet, fully compartmentalised of each module sections, hinged type lockable door,totally enclosed, vermin proof, free standing, suitable ventilated louvers covered with wire mesh, floor mounting , MS base frame of size 100 x 50 x 5 mm thick channel etc including anti-treated with powder coated of approved colour,complete with all internal copper wiring, inter connections of all control & power cables, body earthing etc. all as required as per SLD Technical Specification with the following equipped switch gears & accessories complete in all respect. INCOMING 800 Amp TPN ACB of 50 KA (Ics Value) complete with microprocessor release for O/L, S/C & E/F protection with RS 485 communication port complete. BUSBARS 1000 Amp 4P copper busbar. INSTRUMENTS 96mm x 96mm Digital type ammeter with CTs ( 800/5A) & inbuilt ASS 96mm x 96mm Digital type Voltmeter protected by MCBs with inbuilt VSS 12 stepped Automatic Power Factor Correction (APFC) relay with inbuilt PF parameter. Set of LED indication lamp protected by MCB for RYB Phases, ON & OFF & trip indication on incommer. Switch for auto / manual operation. OUTGOING Switch gear & capacitor bank rating 125A TP MCCB , 25KA with neutral link, Power Contactor and 50KVAR capacitor bank - 4 sets 63A TP MCCB , 25KA with neutral link, Power Contactor and 25KVAR capacitor bank - 6 sets 25A TP MCCB , 25KA with neutral link, Power Contactor and 10KVAR capacitor bank - 4 sets 16A TP MCCB , 25KA with neutral link, Power Contactor and 5KVAR capacitor bank - 2 set - fixed capacitor for transformer. Note:- Each bank connected to outgoing switchgear shall consits of Capacitor duty switch module, single phase Electronic switch, MPP-H (heavy duty) capacitor with 7% detuned harmonic Reactors suitable for 3Phase, 440 V A.C. ±10 %, 50Hz ± 3 % low loss with pressure tear off fuse, Capacitor voltage shall be 525V, suitable rating shall be used to get actual KVAR at 440V, Total dielectric losses < 0.45 KW/ KVAR, switching operation > 10000 and life of Capacitor shall be >150000 Hrs at class D & inrush current > 450 Ir, TP Fuse Base with semiconductor protection Fuse Link, ON/OFF Push Button, ON/OFF LED Indication Lamps protected by MCB, Auxiliary Relay complete. All capacitor shall be placed below compartment of panel with ventlations arrangement as required. Panel described as above
Phase Sequence Relay (Transformer Incomer) Reverse Power Relay (DG Set Incomer) INSTRUMENTS ON EACH OUTGOING BREAKERS/MCCB Digital ammeter (96mm x 96mm) with CT's & ASS. Set of LED ON/OFF indication lamp protected by MCB for breakers. Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication cable. Panel described as above
Earthing with copper earth plate 600 mm X 600mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing, Fixing, Testing & Commissioning of following copper strip wire on surface of wall/ trench including insulator with heat shrinkable sleeves etc. as required. Providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required.
Providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Providing and fixing 50 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supply, installation testing & commissioning of External Lighting wide area protetion system based on Pro-active early streamer esmission (ESE) Technology. No external power source required. Device confirming to NFC 17-102 & UNE 21186 standards. (91 Mtr Level - II radius protection at 5 mtr mast) or Shall be provided for building as per IS; 2309-1989
Supply installation testing & commissioning of Adapter head mast (5 mtrs SS pipe heavy duty 40mm inner dia) clamped suitable on bricks work, wall fixture & all acessories, clamps etc as required)
Supply installation, testing and commissioning of 1Cx70 sqmm PVC insulated 1.1 KV grade flexible copper conductor cable as required
Supply installtion testing & commissioning of maintenance free earting system consists of 3 mtr long, 17mm dia 250 microns UL-listed copper bonded rod with ALLTEC-Terrafill (22kg) Backfill should RoHS & low resitivity certified. The Backfill having not more than 0.20 Ohm/cm resistance, eco friendly, non degradable and non soluble. The earthing pit shall be designed and supplied with Poly plastic Pit Cover non conductive, environment friendly.
Providing and Fixing testing of Test Joints made out of 25x3 mm thick copper strip 125mm long fixtures in 250x180x110mm IP 65 Poly carbonate top transparent box including, testing commissioning as required
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 120 Sqmm. and upto 400 sqmm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 120 sq. mm and upto 400 sq. mm
Laying of one number PVC/XLPE insulated and PVC sheathed power cable of 11 KV grade of following sizes in the existing RCC/Hume / Metal pipe as required. Above 120 Sqmm. and upto 400 sqmm
Laying of one number PVC/XLPE insulated and PVC sheathed power cable of 11 KV grade of following sizes in the existing masonry open duct as required. Above 120 Sqmm. and upto 400 sqmm
supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. 240 Sqmm
supplying and making Outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. 240 Sqmm
Supply of following sizes of 11KV XLPE grade multicore stranded aluminium conductor (Earthed), XLPE insulated PVC sheathed armoured cable conforming to IS: 7098 (Part-I) 1988 complete as required and as per specification encolsed. 3 Core, 240 Sq.mm
Final Testing and commissioning of following ratings Outdoor type package substation with facility for internal lighting, earthing, padlocks etc. Connection between RMU & transformer will be by 3 nos. 1Cx150 sq.mm. Copper XLPE cable and connections from transformer to LT ACB will be by Aluminum busbar connections. RMU shall be capable of making Ring Mains of all ESS(PSS) and as per technical specification and as required HT Switchgear: 3 Way Non Extensible Unit with 2Nos. 630A Isolators and 1No. 630A Circuit Breaker – QTY: 1 No. 3 Way, 11kV, indoor non extensible free standing metal clad SF6 insulated ring main unit type Ringmaster comprising of two numbers 630A fault making/ load breaking switches and one number 630A tee-off circuit breakers complete with all accessories as listed below: • IDMT RELAY for Circuit Breakers – Self Powered, Merlin Gerin type VIP35• The Ring Switches and Tee-Off Circuit Breaker are provided with Integrated Earthing Switches with Making Capacity. • Live cable indicator for ring switches. • SF6 Gas pressure indicator. • Padlocking facility. • Shunt trip coil rated for 230V AC. 750 KVA TRANSFORMER (Manufactured as per IS 1180), OIL Filling requirment As per (IS 1180 PART I : 2014) 750 KVA CSS
AIR CONDITIONING WORK CHILLED WATER EQUIPMENT AIR HANDLING UNITS Supply, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type horizontal/vertical air handling units made of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators, cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of 4/6 row deep as mention below, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters,belt drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply suitably designed for varialbe frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 nos.)and industrial type thermometers (2 nos.) at the inlet and outlet of coil, auto purge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following capacities. AHU shall be complete with suitable capacity of VFD as per below mention capacity. Necessary potential free contacts shall be provided for BMS operation. Ambient condition Guwahati-for summer, monsoon, winter ( DB/WB-100/84, 88/81, 52/51 respectively ) Inside condition-74F RH 50-60% FM AHU b) F/M 36000 CFM 85.0 TR , 65 mm Sp, 4 RD Coil Suggested or As Required Meeting Functional Requirement
h) F/M 19000 CFM 54.0 TR, 65 mm Sp, 6 RD Coil Suggested or As Required Meeting Functional Requirement
i) F/M 17500 CFM 47.0 TR, 60 mm Sp, 4 RD Coil Suggested or As Required Meeting Functional Requirement
j) F/M 16500 CFM 41.0 TR, 60 mm Sp, 4 RD Coil Suggested or As Required Meeting Functional Requirement
k) F/M 13500 CFM 33.0 TR, 60 mm Sp, 4 RD Coil Suggested or As Required Meeting Functional Requirement
m) F/M 9500 CFM 25.0 TR, 60 mm Sp, 4 RD Coil Suggested or As Required Meeting Functional Requirement
C/S AHU f) C/S 4000 CFM 10.0 TR, 50 mm Sp, 4 Rd Coil Suggested or As Required Meeting Functional Requirement
Thermostat Supply, installation, testing and commissioning of automatic control for Units for 2 pipe system (cooling) consisting of snap acting digital thermostat, which will have provision of setting of room temperature, setting off on speed (High, Medium, Low). The quoted price of thermostat shall include the cost of 20mm MS conduits, control cabling, MS Box etc. as required. It shall include all accessories, mountings, wiring be tween thermost at & unit, terminations etc. (BMS Compatibility to be provided)
Insulated Chilled Water Piping Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building & at terrace (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 40-55 Kg / cu m density, insulation material shall be resistant to growth of Fungus as per ASTM C 1338 and resistant to growth of Bacteria as per ASTM E 2180,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation,with reinforced 7 mil woven glass fiber covering in and applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. a) 100 mm dia.(32 mm thick insulation)
b) 80 mm dia. (32 mm thick insulation)
c) 65 mm dia. (32 mm thick insulation)
d) 50 mm dia. (32 mm thick insulation)
Butter fly Valve(Manual) with CI body SS Disc,Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot water circulation as specified. a) 100 mm dia Lever Type
b) 80 mm dia Lever Type
c) 65 mm dia Lever Type
d) 50 mm dia Lever Type
Y-Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specified. a) 100 mm dia
b) 80 mm dia
c) 65 mm dia
d) 50 mm dia
Providing and fixing in position the industrialty pepressure gauges with gunmetal / brass valves complete as required.
Providing & Fixing in position the mercury in glass with industrial type thermometers.
Providing and fixing Auto air vents (Brass MOC) of following size
Pressure Independent Control & Balancing Valve) Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. a) 50 mm Dia
b) 65 mm Dia
c) 80 mm Dia
d) 100 mm Dia
Providing and fixing of PVC drain pipe of 6 Kg /cm2 pressure rating complete with 6mm thick closed cell nitrile rubber insulation, fittings, supports, valves as per specifications & drawings. a) 32 mm Dia
b) 40 mm Dia
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. a) Thickness 0.63 mm sheet
b) Thickness 0.80 mm sheet
c) Thickness 1.00 mm sheet
d) Thickness 1.25 mm sheet
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. a) Thickness 0.63 mm sheet
b) Thickness 0.80 mm sheet
c) Thickness 1.00 mm sheet
d) Thickness 1.25 mm sheet
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers as per specifications.
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.
Fire damper Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. a) Fire damper
b) Actuator
VAV BOXES Supply installation testing and commissioning of VAV box complete with leakage proof damper, differential pressure sensor, motorized al constructed damper, actuator, thermostat with temperature sensors,24V power supply and controller capable to accept analogue /digital signal from thermostat. a) 0-500 CFM VAV BOX
b) 501-1000 CFM VAV BOX
c) 1001-1500 CFM VAV BOX
d) 1501-2000 CFM VAV BOX
e) 2001-2500 CFM VAV BOX
f) 2501-3500 CFM VAV BOX
g) 3600-4500 CFM VAV BOX
h) 4501-5500 CFM VAV BOX
i) 6500-7500 CFM VAV BOX
j) 10000-11000 CFM VAV BOX
Supply, installation, testing & commissioning of 100 mm depth vinyl fabric flexible duct connector with 25mm flange suitable for medium temperature and fire/smoke resistance. Meets the requirement of NFPA 701. Measured in surface area. 100 mm
Supply, installation and balancing of extruded aluminium powder coated air louvers complete with aluminium wire mesh bird screen as per specifications. a) Fresh air louvers (with dampers)
Duct Thermal & Acoustic Insulation Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. a) 19 mm thick
b) 25 mm thick
Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.
Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications.
MS Cable Trays Supplying and installing following size of perforated paintedwith powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. a) 100 mm width X 50 mm depth X 1.6 mm thickness
Supply of LT cable Supply of following size of 1.1KV grade multicore Copper conductor XLPE insulated & PVC sheathed armoured power cable as per IS: 7098 (Part-1) 1988 complete as required. a) 4C- 10 sq mm
b) 4C- 6 sq mm
c) 2C-1.5 sq mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 25 mm Dia
b) 32 mm Dia
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. a) 25 mm Dia
b) 32 mm Dia
Earthing Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required a) Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
b) Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Inline Fans (Accoustically Insulated) Supply, installation, testing and commissioning of ducted Inline Fans of GSS construction duly powder coated (rectangular box type for upto 20 mm WG SP and circular type for 10 mm WG SP) with centrifugal blower and motor encased in sheet metal casing, canvas connection etc. The Fan motor shall be suitable for operation on 220 V± 10%, 50 Hz, 1 phase AC supply. The Fan assembly shall conform to specifications and in accordance with requirements of drawings and Schedule of Quantities. a) Air Quantity : 900 CFM Static Pressure : 20 mm wg Motorrating : As Required
b) Air Quantity : 700 CFM Static Pressure : 10 mm wg Motorrating : As Required
b) Air Quantity : 600 CFM Static Pressure : 10 mm wg Motorrating : As Required
Air Quantity : 500 CFM Static Pressure : 10 mm wg Motorrating : As Required
Air Quantity : 400 CFM Static Pressure : 10 mm wg Motorrating : As Required
Air Quantity : 300 CFM Static Pressure : 10 mm wg Motorrating : As Required
Air Quantity : 200 CFM Static Pressure : 10 mm wg Motorrating : As Required
Air Quantity : 100 CFM Static Pressure : 10 mm wg Motorrating : As Required
b) Air Quantity : 300 mm Dia, 3 mm St. Pr., 900 RPM or as per OEM, fan suitable for 220± 5% volts 50 cycles, 1 phase AC Power supply as Required
c) Air Quantity : 450 mm Dia, 3 mm St. Pr., 900 RPM or as per OEM, fan suitable for 220± 5% volts 50 cycles, 1 phase AC Power supply as Required
AXIAL FLOW FANS Supply, installation, testing and commissioning of AMCA certified for sound and air performance (FEG) Tube Axial fan complete with tube casing in MS standard construction powder coated, aluminium impeller with adjustable blade angles,vibration isolator and directly coupled to TEFC Sq.cage induction motor, suitable for 415V±10%, 50 Hz. 3 phase electric supply complete with required hardware etc. as per specification complete as required. a) Air Quantity : 17000 CFM (Kitchen FA) Static Pressure : 20 mm wg Duty : Pressurization
b) Air Quantity : 9500 CFM Static Pressure : 25 mm wg Duty : Pressurization
e) Air Quantity : 7000 CFM Static Pressure : 25 mm wg Duty : Pressurization
f) Air Quantity :5500 CFM Static Pressure : 20 mm wg Duty : Pressurization
h) Air Quantity :3000 CFM (Kitchen FA) Static Pressure : 20 mm wg Duty : Fresh/Exhaust
b) Air Quantity : 11500 CFM Static Pressure : 25 mm wg Duty : DG Exhaust
DRY SCRUBBER Supply, Installation, Testing and Commissioning of dry type Ceiling/Floor mounted Scrubber comprising electrostatic section multi cell type with 16 G powder coated galvanised steel sheet housing of 16 G (1.4 mm) thick system, bottom drain and metallic mesh filter. The electronic air cleaner shall be the two- stage dual voltage plate type cells and efficiency of 90% as per ASHRAE test Standard for dry particulate. Ionizing- collecting cell of one-piece construction. Power supply shall be 100% solid state. on 200 to 240 VAC, 50HZ, 1Phase input with an LED light indicating the performance status. All unit shall be with factory fitted UV lamp as per specification etc complete as required. a) 18000 cfm capacity for kitchen
b) 3500 cfm capacity for kitchen
Supply, installation, testing and commissioning of Suitable SISW Backward Curved centrifugal Fan sheet metal double construction complete with TEFC Induction Motor, Drive Assembly, Base Frame, Vibration Isolators and other accessories etc as per specification complete as required.motor should be suitable for outdoor application. a) Capacity - 18000 CFM, 35 mm St. Pr.
b) Capacity - 3500 CFM, 35 mm St. Pr.
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. a) Thickness 0.63 mm sheet
b) Thickness 0.80 mm sheet
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. a) Thickness 0.63 mm sheet
b) Thickness 0.80 mm sheet
16 gauge MS duct work welded construction. Duct shall have fire rated coating compound. Fire rated coating compound used forconstruction of fire rated duct work shall be protected with minimum 0.7mm to 1mm nominal thickness tested to properties as per the requirements of BS 476: 6 & amp; 7, including non-combustibility Class O and fire propagation - Class 1 surface spread of flame & amp; materials in accordance with building regulations.
Supply, installation, testing & commissioning of 100 mm depth vinyl fabric flexible duct connector with 25mm flange suitable for medium temperature and fire/smoke resistance. Meets the requirement of NFPA 701. Measured in surface area.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers as per specifications.
Supply, installation and balancing of extruded aluminium powder coated air louvers complete with aluminium wire mesh bird screen as per specifications. a) Exhaust air louvers (without volume control dampers)
MS Cable Trays Supplying and installing following size of perforated paintedwith powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. a) 100 mm width X 50 mm depth X 1.6 mm thickness
b) 150 mm width X 50 mm depth X 1.6 mm thickness
Supply of following size of 1.1KV grade multicore Copper conductor XLPE insulated & PVC sheathed armoured power cable as per IS: 7098 (Part-1) 1988 complete as required. a) 4C- 10 sq mm
b) 4C- 6 sq mm
c) 4C- 4 sq mm
d) 2C- 1.5 sq mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 25 mm Dia
b) 32 mm Dia
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. a) 25 mm Dia
b)32 mm Dia
Earthing Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Shree Gautam Construction Co Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid