Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.9 LAccepted-AOC M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹25.7 L+₹2.7 L (12.0%)Rejected-AOC SITE NO 29 30 1ST CROSS NAGAPPA REDDY LAYOUT KAGGADASPURA CV RAMAN NAGAR BANGALORE 560093 | BENGALURU URBAN | KARNATAKA | 560093 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹25.8 L+₹2.8 L (12.4%)Rejected-AOC | L3 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹59,000
Closing Date
21 Jun 2024, 6:00 pmClosed
GE (AF) BANGALORE
GE (AF) BANGALORE, HQ TC AIR FORCE , BANGALORE - 560006
REPAIR/MAINT OF COOLING APPLIANCES INCLUDING WINDOW/SPLIT ACs/AIR CURTAINS/VOLTAGE STABILISERS/REFRIGERATORS/DEEP FREEZERS REPLACEMENT OF UNSERVICEABLE SPARES AND FIXTURES AT CHAF BANGALORE
2024_MES_655695_1
8231/E8
Open Tender
Civil Works
Item Rate
330 days
GE (AF) BANGALORE
AS PER NIT
5 documents required · 5 mandatory
₹500
GE (AF) BANGALORE
₹59,000
31 Aug 2024
24 May 2024
29 Jun 2024
24 May 2024
21 Jun 2024
7 Jun 2024
25 May 2024 - 31 May 2024
Amount
S&F in Replacement hermatically sealed new compressor for split AC of capacity 1.5 Ton of existing make including disconnecting the electrical and refrigerant connection of defective sealed unit of split AC of capacity 1.5 Ton and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed. Note:- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
All as per Sl item No 1.00 here in before but for 2 TR split type AC complete all as specified and directed.
All as per Sl item No 1.00 here in before but for 3 TR split type AC 3Ph 415V 50Hz. complete all as specified and directed.
S&F in replacement Remote assembly of existing make corded/cordless for split type AC of capacity 1/1.5 TR complete all as specified and as directed.
S&F in replacement Remote sensing unit of existing make for split type Ac of capacity 2 TR complete all as specified and as directed.
S&F in replacement Remote sensing unit for 2.5 TR split type Ac of existing Make complete all as specified and as directed.
S&F Condenser coil in replacement after disconnecting the refrigerant connection of defective condenser coil unit of split AC of capacity 1.5 Ton and replacing the condenser coil unit connecting the same unit with refrigerant connections complete all as specified and as directed.
All as per Sl item No 7.00 here in before but for 2.0 TR Split type AC.
All as per Sl item No 7.00 here in before but for 3.0 TR Split type AC
S&F in replacement capacitor 35 mfd suitable for split type Air Conditioner of existing make and capacity of 1 TR , complete all as specified and as directed.
S&F in replacement capacitor 45 mfd suitable for split type Air Conditioner of existing make and capacity of 1.5 TR , complete all as specified and as directed.
S&F in replacement capacitor 55 mfd suitable for split type Air Conditioner of existing make and capacity of 2 TR , complete all as specified and as directed.
M&L for pressure testing and rectifying the leakages found in the system of split type ACs of capacity 1/1.5/2/3 Ton and including vacuumizing,charging and checking the gas pressure to desire level complete for satisfactory functioning all as specified and as directed. Note:Topping up of gas will be measured and paid seperately.
S&F in replacement Blower motor, suitable for split type Air Conditioner of of capacity 1.5 TR , all as specified and as directed.
S&F in replacement Potential relay, suitable for split type Air Conditioner of 1.5 TR capacity, all as specified and as directed.
S&F in replacement Potential relay, suitable for split type Air Conditioner of existing make of 2 TR capacity, all as specified and as directed.
S&F in replacement Submain wiring along with two single core PVC insulated FRLSH copper conductor of size 2.5 sqmm and earth wire of size 2.5 sqmm incl in PVC casing caping in surface/ recessed as required all as specified and directed. Note: All three run cable alongwith PVC casing capping is considered as a unit.
All as per Sl Item No 17.00 here in before but of size 4 sqmm.
S&F in replacement Condenser Fan motor of existing make suitable for split type Air Conditioner of capacity 1.5 TR all as specified and as directed.
M&L for servicing complete Split type ACs of capacity 1/1.5/2.0/3.0 Ton of any make as and when ordered including cleaning of air filters, greasing of fan/blower motors, electrical connections etc. as in preventive maintenance all as specified and as directed. Note:Replacement of spares, charging of gas, etc. shall be measured and paid separately under relevant items of this Schedule.
S&F in replacement of Front grill, suitable for split type Air Conditioner of existing make of 1.5 TR capacity, complete all as specified and as directed.
S&F in replacement Thermostat, suitable for split type Air Conditioner of existing make 1.5 TR capacity,complete all as specified and as directed.
M&L for shifting of Air Conditioner,Split type capacity 1/1.5/2/3 TR from existing location to new location as per user requirement and installing, toping up of gas, replacement of copper tubing connecting up, commissioning and testing complete all as specified and as directed. Note: Topping up of gas and copper tubing will be measured and paid seperately
M&L for Refrigerant gas,(R 22) Freon suitable for cooling equipments supplied and filled complete all as specified and as directed.
S&F in replacement Copper tube, 15 mm / 18 mm dia, superior quality suitable for refrigeration and suction lines of split ACs, drawn trough pipes/ fixed to walls/ laid on floor or roof all as specified and as directed
S&F in replacement Copper tube, 9 mm dia, superior quality suitable for refrigeration and discharge lines of split ACs, drawn trough pipes/ fixed to walls/ laid on floor or roof complete all as specified and as directed.
M&L for Refrigerant gas,(R 32) suitable for cooling equipments supplied and filled all as complete specified and as directed.
M&L for Refrigerant gas,(R 410) suitable for cooling equipments supplied and filled all as complete specified and as directed.
S&F in replacement invertor AC Printed Circuite Board (PCB) ,suitable for split type inverter Air Conditioner of existing make of 1.5 TR capacity, complete all as specified and as directed.
S&F in replacement hermatically sealed new compressor for water cooler 40/80 ltr/Hr cooling capacity of existing make including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 40/80 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed Note:- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
All as per Sl item No 30 here in before but for 60/120 litres/Hr capacity.
All as per Sl item No 30 here in before but for 150/150 litres/Hr capacity.
M&L for servicing complete water cooler, storage type, upto 150 litres capacity including cleaning, checking of electrical/ water supply connections etc. as in preventive maintenance all as specified and as directed. Note: Replacement spares, charging of gas, etc. shall be measured and paid separately under relevant items of this Schedule.
S&F in replacement paper type relay, suitable for Water Cooler of existing make of 40/80 ltr/hr capacity, all as specified and as directed.
S&F in replacement paper type relay, suitable for Water Cooler of existing make of 60/120 ltr/hr capacity, all as specified and as directed.
S&F in replacement paper type relay, suitable for Water Cooler of existing make of 150/150 ltr/hr capacity, all as specified and as directed.
S&F in replacement Electric Condenser fan motor, AC 230 volt, single phase with recommended RPM etc suitable for water cooler of existing make of 40/80 litres capacity, all as specified and as directed.
All as per Sl item No 37.00 here in before but for 60/120 litres/Hr capacity.
All as per Sl item No No 37.00 here in before but for 150/150 litres/Hr capacity.
S&F in replacement capacitor 10 mfd, suitable for water cooler of existing make and capacity complete all as specified and as directed.
S&F in replacement capacitor 15 mfd suitable for water cooler of existing make and capacity complete all as specified and as directed.
M&L for repairing the leakage in the steel water tank of water cooler of any capacity by welding brazing/ soldering complete all as specified and as directed.
S&F in replacement self closing push type bib tap 15mm dia made out of cast copper alloy chromium plated suitable for water cooler conforming to ISI mark, including testing and leak proof etc.complete all as specified and as directed.
S&F in replacement PVC connection pipe 450mm long 15 mm dia with brass unions with washers on both the ends complete all as specified and as directed.
S&F ball brass valve high pressure 15mm dia complete fitting such as PVC polythene ball, layer check nut washer etc for water cooler of any capacity complete all as specified and directed.
S&F in replacement Stainless steel tray suitable for water cooler of 40/80 ltr/hr capacity complete all as specified and as directed.
S&F in replacement Stainless steel tray suitable for water cooler of 150/150 Ltr/hr capacity complete all as specified and as directed.
M&L for pressure testing and rectifying the leakages found in the system of water cooler of capacity 40/ 80 litres and vacuuming and charging refrigerant gas (R-134a) and filling new compressor oil etc. complete for satisfactory functioning all as specified and as directed. Note:Topping up of gas will be measured and paid seperately
All as per Sl item No 48.00 here in before but for 60/120 litres/Hr capacity.
All as per Sl item No 48.00 here in before but for 150/150 litres/Hr capacity.
Taking down corroded bottom portion of water cooler of 40/80 ltr/hr capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water cooler including two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour all as specified and as directed.
Taking down corroded bottom portion of water cooler of 150/150 ltr/hr capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water cooler including two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour all as specified and as directed.
S&F in replacement condensing coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity complete all as specified and directed.
S&F in replacement Door gasket, suitable for lid of water cooler of 40/80 ltr/hr capacity, all as specified and as directed.
M&L for preparing the old painted surface of the water coolers of capacity up to 40/80 Ltr/hr capacity and spray painting with synthetic enamel paint all as specified and as directed.
M&L for preparing the old painted surface of the water coolers of capacity cap 150/150 Ltr/hr capacity,and spray painting with synthetic enamel paint all as specified and as directed.
S&F in replacement evaporator coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity complete all as specified and directed.
S&F in replacement PVC drain out pipe 30mm dia bore as per existing including providing necessary GI clamps, nut bolt etc.all as specified and as directed
S&F inBreplacement evaporator coil, suitable for refrigerator of 165 to 255 ltrs any make size and type complete all as specified and as directed.
All as per Sl item No 59.00 here in before but for 260 to 310 litres capacity.
All as per Sl item No 59.00 here in before but for 315 to 360 litres capacity.
S&F in replacement hermatically sealed new compressor of 190 Ltr capacity of refrigerator of existing make including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 190 litres complete all as specified and as directed. Note:- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
All as per Sl item No 62.00 here in before but for invertor type 285 litres capacity.
All as per Sl item No 62.00 here in before above but for 308 litres capacity.
S&F in replacement Thermostat, suitable for refrigerator of any make 165 to 360 litres capacity, complete all as specified and as directed.
S&F in replacement overload relay, box type, suitable for refrigerator of existing make of 165 to 255 litres capacity, complete all as specified and as directed.
M&L for servicing of Refrigerator, 165 to 255 litres capacity including cleaning, checking of electrical connections etc complete as in preventive maintenance all as specified and as directed. Note:Replacement spares, charging of gas, etc. if required shall be measured and paid separately under relevant items of this Schedule.
All as per Sl item No 67.00 here in before but for 260 to 310 litres capacity.
All as per Sl item No 67.00 here in before but for 315 to 360 litres capacity.
S&F in replacement condensing coil for refrigerator of capacity 165 to 255 Ltr complete all as specified and directed.
All as per Sl item No 70.00 here in before but for 260 to 310 litres capacity.
All as per Sl item No 70 .00 here in before but for 315 to 360 litres capacity.
S&F in replacement Freezer door, suitable for Refrigerator of any make, 165 to 255 litres capacity, all as specified and as directed.
All as per Sl item No 73 .00 here in before but for 260 to 310 litres capacity.
All as per Sl item No 73 .00 here in before but for 315 to 360 litres capacity.
S&F inreplacement chiller tray, suitable for Refrigerator of any make, 165 to 255 litres capacity, complete all as specified and as directed.
All as per Sl item No 76.00 here in before but for 260 to 310 litres capacity.
All as per Sl item No 76.00 here in before but for 315 to 360 litres capacity.
M&L for preparing the old painted surface of refrigerator of capacity 165 litres to 360 litres and spray painting with synthetic enamel paint of approved colour all as specified and as directed.
S&F in replacement Gasket, suitable for door of Refrigerator of any make, 165 to 255 litres capacity all as specified and as directed.
All as per Sl item No 80.00 .00 here in before but for 260 to 310 litres capacity.
All as per Sl item No 80.00 .00 here in before but for 315 to 360 litres capacity.
S&F in repair magnetic beeding for refrigetator of cap 200 ltrs to 310 ltrs complete all as specified and directed.
S&F superior quality plastic/PVC Ice cube tray for refrigerator of cp 200 Ltrs to 310 ltrs complete all as specified and directed.
S&F in replacement Vegetable tray, suitable for Refrigerator of any make, 165 to 255 litres capacity, complete all as specified and as directed.
All as per Sl item No 85.00 here in beforebut for 260 to 310 litres capacity.
All as per Sl item No 85.00 here in before but for 315 to 360 litres capacity.
M&L for pressure testing and rectifying the leakage found in the system of refrigerator of capacity 165 to 255 litres including vacuuming and charging the refrigerant (R 134a gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning all as specified and as directed. Note:Topping up of gas will be measured and paid seperately
All as per Sl item No 88.00 here in before but for 260 to 310 litres capacity.
All as per Sl item No 88.00 here in before but for 315 to 360 litres capacity.
S&F in replacement hermatically sealed new compressor for deep freezer of capacity 320 ltr including disconnecting the electrical and refrigerant connection of defective sealed unit of deep freezer 320 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed. Note:- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
All as per item no 91.00 here in before but of capacity 500 ltr
S&F in replacement top plug 3 pin 15 A bakelite all as specified and as directed.
S&F in replacement top plug 3 pin 5A bakelite all as specified and as directed.
Supply and charging of refrigerant gas R-134a to water cooler , refrigerator and deep freezer of any type, make and capacity all as specified and as directed
S&F in replacement LED bulb 3 watt 230v threaded type for refrigetator of cap 200 ltrs to 310 ltrs complete all as specified and directed.
M&L for dismantling the transformer from the stabilizers of following capacity and removing the old / burnt transformer and replaced with new transformer of same design and capacity.
S&F in replacement of Printed circuit board (PCB) suitable for refrigerator 165 Ltr to 255 ltr capacity of existing make,complete all as specified and directed.
All as per Sl item No 98.00 here in before but for 260 to 310 Ltrs capacity.
All as per Sl item No 98.00 here in before but for 315 to 360 Ltrs capacity.
Replacement of following spare parts for 1 KVA to 2 KVA capacity stabalizers complete all as specified and directed.
Relay set ( set of two )
PCB ( Printed circuit board)
Replacement of following spare parts for 4 KVA to 5 KVA capacity stabalizers complete all as specified and directed.
Relay set ( set of two )
PCB ( Printed circuit board)
S&F in replacement digital voltmeter 0-250 volt for stabilizers any type as per existing complete all as specified and directed.
S&F in replacement heat insulation superior quality nitrile rubber of 9 mm thickness, ISI marked for copper tubing of any size of refrigerant line including necessary clamps,PVC tape knots,in all respects complete all as specified and directed.
S&F in replacement of AC indoor unit of capacity 1.5 Ton of existing make including necessary electrical connection and refrigerant pipe connection complete all as specified and directed.
S&F of sheet metal enclosure with socket plug top and neutral enclosure with a two pin and earh plug and socket complete with one SPN MCB 20 Amps 'C' curve type, complete all as specified and directed.
S&F in replacement of MCB SP 5-32 Amps 'C' Curve type 10 KA 240 Volt complete with connection and testing complete all as specified and directed.
Attending daily complaints and detecting faults at site of any type Split AC/Refrigerator/Deep freezer/water cooler/Air curtains and any make in CHAFB area under AGE E/M CHAFB and rectifying the defects and make it functional including replacing of unserviceable defective spares/accessories Note :- (i) Spare parts shall be measured and paid under respective item of schedule (ii) Essential materials like insulation tape ,screws and all tools required for detecting faults shall be deemed to be included in the quoted rate.(iii) The work is of day to day maintenance, required AC/Ref mech and a helper has to attend daily for carrying out the work. (iv) Non rectification of complaints penal charges of Rs 300/- per complaints shall be imposed.
M&L Servicing complete 6 bed mortuary cabinet of existing make as and when ordered including cleaning of air filters,cabin inside, greasing of fan/blower motors, electrical connections etc. as in preventive maintenance all as specified and as directed. Note: Replacement spares, charging of gas, etc. shall be measured and paid separately under relevant items of this Schedule.
M&L Servicing complete Cassette type AC of capacity 4 Ton of existing make as and when ordered including cleaning of air filters, greasing of fan/blower motors, electrical connections etc. as in preventive maintenance all as specified and as directed. Note: Replacement spares, charging of gas, etc. shall be measured and paid separately under relevant items of this Schedule.
M&L Servicing of Air curtains unit, of any type capacity and length, single phase AC, 230 Volts as in preventive maintenance alongwith blower assembly filter and other components including checking electrical connections complete all as specified and as directed.
M&L Blower motor assembly of Air curtain unit of existing type, capacity and length, single phase AC, 230 Volts as including electrical connections complete in repairs all as specified and as directed.
M&L Servicing complete Tower AC of capacity 3 Ton of existing make as and when ordered including cleaning of air filters, greasing of fan/blower motors, electrical connections etc. as in preventive maintenance all as specified and as directed. Note:Replacement spares, charging of gas, etc. shall be measured and paid separately under relevant items of this Schedule.
Aavani BUILDERS AND CONTRACTORS
mahadevi Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .