Executive Engineer (Electrical),
Office of the Executive Engineer (Electrical), P.W.D., Electrical Division, Thiruvarur.
SR to EI, UPS and Power plug arrangements to the Court Halls, Court Office rooms and Corridors in Combined Court Campus at Thiruvarur in Thiruvarur District.
2026_PWD_709995_1
99/2026-27/ ELE/TVR
Open Tender
Electrical Works
Lump-sum
30 days
Thiruvarur
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹5,700
1 Oct 2026
1 Oct 2026
15 Oct 2026
1 Oct 2026
15 Oct 2026
1 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Renewal by supply and fixing of 3Nos 5A (3pin and 2pin) combined flush type wall socket with control switches concealed in suitable TW box covered with hylem sheet in flush with wall with earth connection. (for computer plug socket) | 15 | Nos | 650 | ₹9,750 |
| 2 | Renewal by supply and fixing of 5A / 15A 3pin combined flush type wall socket with 15A flush type switch on suitable TW box. | 3 | Nos | 469 | ₹1,407 |
| 3 | Renewal by supply and fixing of 1No 6A two module 3 pin socket, 1No 6A one module switch on suitable module surface mounting box (plastic) with module cover plate (plastic) on wall with connections. (Higher End) | 1 | No | 617 | ₹617 |
| 4 | Renewal by supply and run of 2 of 2.5sq.mm PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 2.5sq.mm copper wire with painting of suitable colour. | 150 | Mtrs | 203 | ₹30,450 |
| 5 | Renewal by supply and fixing of 6A to 32A Single Pole MCB on existing DB with connection. | 5 | Nos | 270 | ₹1,350 |
| 6 | Renewal by supply and installation of 1.5TR (4500 K.cal/Hr) ABS Plastic Split type Air Conditioner with Amdt No. 1 to 2 fitted with rotary compressor operating on refrigerant Non-CFC suitable for wall mounting for operation on 230V, 50Hz single phase AC supply with star rating as per BEE specification and capable of performing the functions of Cooling, Dehumidifying, Air Circulating, Filtering. The installation works for the above split type AC units includes the following.
1. Mounting / Fitting Indoor and outdoor units at their respective locations.
2. Laying refrigerant pipeline of required length connecting Not exceeding 3 metre distance and both units after drilling hole/holes in the wall if required.
3. Insulating the suction pipe with expanded polyethylene foam 5mm tubing.
4. Laying 15mm dia flexible PVC drain pipe to throw out the condensate water being formed within the indoor unit.
5. Leakage testing the entire system unit.
6. Charging refrigerant gas in the unit.
7. Suitable electric wiring to be provided with 2.5sq.mm PVC insulated copper wire between indoor and outdoor units up to 6Mtrs length and up to switch within 3Mtrs of location of indoor unit. | 1 | No | 34,660 | ₹34,660 |
| 7 | Renewal by supply and installation of 2.0TR (6000 K.cal/Hr) ABS Plastic Split type Air Conditioner with Amdt No. 1 to 2 fitted with rotary compressor operating on refrigerant Non-CFC suitable for wall mounting for operation on 230V, 50Hz single phase AC supply with star rating as per BEE specification and capable of performing the functions of Cooling, Dehumidifying, Air Circulating, Filtering. The installation works for the above split type AC units includes the following.
1. Mounting / Fitting Indoor and outdoor units at their respective locations.
2. Laying refrigerant pipeline of required length connecting Not exceeding 3 metres distance and both units after drilling hole/holes in the wall if required.
3. Insulating the suction pipe with expanded polyethylene foam 5mm tubing.
4. Laying 15mm dia flexible PVC drain pipe to throw out the condensate water being formed within the indoor unit.
5. Leakage testing the entire system unit.
6. Charging refrigerant gas in the unit.
7. Suitable electric wiring to be provided with 2.5sq.mm PVC insulated copper wire between indoor and outdoor units up to 6Mtrs length and up to switch within 3Mtrs of location of indoor unit. | 1 | No | 46,140 | ₹46,140 |
| 8 | Renewal by supply and installation of 4KVA Electronic Automatic Voltage Stabilizer with Input Voltage range of 170V – 270V and Output Voltage range 200V to 240V with High and Low Voltage cut off and 3 minutes time delay relay with demonstration.. | 1 | No | 4,176 | ₹4,176 |
| 9 | Renewal by supply and Installation of 5KVA Electronic Automatic Voltage Stabilizer with Input Voltage range of 170Volt – 270 Volt and Output Voltage range 200Volts to 240 Volts with High and Low Voltage cut off and 3 minutes time delay relay with demonstration. | 1 | No | 4,646 | ₹4,646 |
| 10 | Renewal by supply and fixing of angle Iron frame work to rest the outdoor unit. | 2 | Nos | 979 | ₹1,958 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.10 MB
Combinedcourttvr.pdf
Tender Documents • 0.76 MB
BOQ_853162.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .