| 1 | L1₹30.9 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹35.8 L+₹4.3 L (13.8%)Rejected-Finance 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹38.0 L+₹6.5 L (20.8%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹38.9 L+₹7.4 L (23.7%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹39.9 L+₹8.5 L (26.9%)Rejected-Finance D 89 SHASTRI NAGAR MEERUT UTTAR PRADESH PIN 250004 | MEERUT | MEERUT | UTTAR PRADESH | 250004 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
29 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Vijay Kumar Sharma
Garrison Engineer West Agra 62 station Road Agra Cantt
SPECIAL REPAIR TO OF BUILDING NO P 16 A OF NCC GP HQ UNDER GE W AGRA
2021_MES_479918_1
8012/841/E8
Open Tender
Civil Works
Item Rate
180 days
Ge West Agra
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Ge West Agra
₹87,000
27 Dec 2021
6 Oct 2021
2 Nov 2021
6 Oct 2021
29 Oct 2021
21 Oct 2021
60 days
Amount
Demolition of cement concrete (unreinforced) in any position not exc 15cm thickness (below or above ground level) complete all as specified and directed. Note: Removal of demolished material will be measured & paid separately under respective item
Disposal of demolished materials exc 1.50 km but not exc 5 km and depositing where directed complete all as specified and directed.
Cutting grooves in brick wall 75mm wide and 65mm deep and shaping horizontal face of groove with CM 1:3 or PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) complete all as specified and directed.
M&L cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) in padding, roof kerbs and similar work complete all as specified and directed.
M&L cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in coping and similar work, slightly rounded or chamfered angles and throating including all necessary use & wasteof form work complete all as specified and directed.
M & L for water proofing treatment of roof slab all as followes: - (a) M&L for preparation of roof surfaces by brushing, cleaning and Applying a priming coat with bitumen primer @ 0.5 ltr/Sqm (b) Applying a hot blown bitumen grade 85/25 @ 1.2 Kg/sqm (c) Laying APP modified water proofing membrane weighing not less than 3 Kg/Sqm will be laid over applied bitumen. (d) Applying a tack coat of hot bitumen grade 85/25 @ 1.2 Kg/Sqm and sand in confirming to Zone II in dry condition will be dusted over the bitumen @1.00 Kg/Sqm
M&L brick tiles 40 mm thick laid over 15 mm thick screed bed in CM 1:6 and jointed in CM 1:3 with linced oil @ 5% by weight of cement complete all as specified and directed.
M&L machine cut kota stone slab 20-25 mm thick as in floor etc. laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and mirror polishing including 20mm thick screed bed in CM (1:6) as in floor complete all as specified and directed.
M&L 100mm thick cement concrete 1:4:8, type D-2 (using 40mm graded stone aggregate) as in floors/hard standing complete all as specified and directed.
M&L sand cushion under floors/paver blocks, spreading and levelling in layers n exc. 25 cm thick complete all as specified and directed.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade With Grey Cement and pigment complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and pre-cast concrete articles complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks old size (EXCEPT BRICKS), straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified & directed.
M&L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified & directed
M&L for coloured glazed ceramic tiles (Digital & designer Pattern) in vertical surface 350 x 250 x 7 mm / 450 x 350 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match tiles including taking down tiles with cement plaster and 10mm thick rendering in CM 1:4 on brick wall complete all as specified and as directed.
M&L glazed ceramic non skid joint free coloured tiles (1st quality / premium quality) 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.11Sqm but not exc. 0.18 Sqm as in floors, skirtings etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed or bedding layer of cment mortar (1:6) complete all as specified and directed.
M&L for vitrified ceramic light shade tiles 10mm thick (square /rectangular), polished (Ist quality / Premium quality), area of each tiles n' exc 0.36 Sqm in floors etc, laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, complete all as specified and directed
M&L for vitrified ceramic light shade tiles 10mm thick (square /rectangular), polished (Ist quality / Premium quality), area of each tiles n' exc 0.36 Sqm in skirting etc, over and including 10 mm thick rendering in cement mortar 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, including taking down existing tiles complete all as specified and directed.
Taking down cement or cement lime plaster of any discription on brick or stone walls/ ceilings etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:6 on any faces of brick or concrete surfaces of walls & finishing the surface even and smooth complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:4 on brick or concrete surface with water proofing compound as per manufacturer's instructions finished fair complete all as specified and directed. Note : Water proofing compound will be measured and paid seperately under respective item of Sch ‘A’.
M & L for rendering 10mm thick in CM 1:4 on ceiling surface finished even and smooth without using extra cement complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying three coats of white wash on wall complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of priming paint complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of average 1mm thick Birla putty complete all as specified and directed.
M&L for preparation of old decorated plastered or un-plastered surface of wall and applying one coat of white wash complete all as specified and as directed.
M&L for preparation of old decorated plastered or un-plastered surface of ceiling and applying one coat of white wash complete all as specified and as directed.
M&L for preparation of old plastered or unplastered surfaces of wall and applying one coat of cement base paint (snowcem) white or tinted complete all as specified and directed.
M&L for preparation, washing, rubbing down and stopping of old distempered surfaces of walls and applying one coat of distemper oil emulsion (washable) complete all as specified and directed.
M&L for preparation by complete removal of existing treatment old plastered or unplastered surfaces of wall and applying two coat of distemper oil emulsion over a coat of 1mm thick wall care putty all as specified and directed.
M&L for preparation of plastered surfaces and applying one coat of weather proof paint in different tint as in band/strips in narrow width and similer works complete all as specified and directed.
S&F mild steel joist channel angle or tee sections fixed independently with out connecting plates etcof grade fe-410-0 & fe 310-0 complete all as specified and directed..
S&F 5.0 cm thick sand stone slabs in sun shades, chajjas, shelves, roof slabs etc n.exc. 2m in length punched dressed on face and along exposed edges, self faced on other side and set and pointed in CM 1:4 complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connection complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connection complete all as specified and directed.
S&F 15mm bore steel water tubing, medium grade, galvanized including fittings and fixed to walls, ceilings, floors or laid in floors complete all as specified and directed.
S&F 20mm bore steel water tubing medium grade galvanized including fittings and fixed to walls, ceilings, floors or laid in floors complete all as specified and directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth etc. brick walls complete all as specified and directed.
S&F in repairs CP bib taps fancy type 15 mm cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as pecified and directed.
S&F in repairs CP Bib taps fancy type long body 15 mm cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as pecified and directed.
S&F in repairs 10 ltrs capacity PVC flushing cistern low level (white) with inlet ball valve and handle including brackets, rubber bush, washers etc complete all as specified and directed.
S&F in repair 15 mm bore CP angle/stop valves, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified & directed.
S&F in repairs 15mm concealed stop cock, chromium plated fancy type with long shank and cup complete all as specified and directed.
S&F in repairs towel rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms) complete all as specified & directed.
S&F in repair PVC connection 15mm size with PTMT nuts, 600 mm long complete all as specified and directed.
S&F in repairs Vitreous china wash basin white flat back size 550 x 400mm including waste pipe, chain, plug, brackets complete all as specified and directed.
S&F in repairs white vitreous China European wash down water closet pan fixing with bolts including connecting to 100mm bore CI ‘P’ or ‘S’ trap with following accessories:- a) White PVC low level flushing cistern 10 ltrs capacity with inlet float valve - 01 b) PVC flush pipe 32 mm, 80 cm long- 01 d) Plastic seat cover - 01
S&F 15mm bore, CP fancy type Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed.
S&F waste coupling of PTMT (half or full threaded) (Minimum weight 32mm- 45gms) of 32mm bore suitable for wash hand basin complete all as specified and directed.
S&F 32 mm dia PVC waste pipe for wash basin /sinks 800mm long complete all as specified and directed.
S&F in repairs 32 mm dia PVC waste pipe for wash basin /sinks 800mm long complete all as specified and directed.
S&F in repair 110mm bore PVC (SWR) pipes, type 'A', single socketed in any length with rubber ring joints, fixed to wall/laid in trenches complete all as specified and directed.
S&F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
S&F in repair vitreous china squatting pan Orissa pattern size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe) complete all as specified and directed.
S&F in repair 500 ltrs capacity rotational moulded polyethylene water storage tank double layered, ISI engraved (cylindrical vertical with closed top) and PVC threaded lid, hoisted and fixed in position complete all as specified & directed.
S&F 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe 20 mm dia (minimum weight - 210 gm) complete all as specified and directed.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in jambs, pillars, window cills, cooking platforms and like in cement mortar 10mm (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. Note: Moulding to edges will be measured & paid separately.
Labour only for edge moulding of granite, marble etc complete all as specified and directed.
S&F in repairs kitchen sink made of stainless steel 1mm thick with plugs, washers and PVC wasts pipe including bedding in cement mortar on to dwarf wall and connecting union to pipe, overall size 495mm x 420 mm bowl size 410mm x 330mm x 160 mm complete all as specified and directed.
S&F in repair plate rack of 1mm thick stainless steel grade 304, of size 900x600mm with three shelves complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n. exc 1.5 Sqm each complete all as specified and directed.
S&F Steel windows with side hung shutters including box type hinge with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F Steel windows with side hung shutters including projecting type hinge with steel handle and steel peg stay, complete with out glazing bars, dovetailed or welded complete all as specified and directed.
S&F steel ventilators with top hung shutters including hinges, steel peg stay complete all as specified and directed.
S&F Mild steel work in framed work such as grills, gratings, guard bars etc, with ends of bars shouldered and/ or riveted, or forged into spikes, and similar work confirming to Fe 410 - O or Fe 310 - O complete all as specified & directed.
M&L for preparation of new steel surface over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F 3 mm thick sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed.
S&F 3 mm thick figured glass, pin headed type and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 Sqm but not exc 4 sqm each complete all as specified and directed.
M&L resecuring or easing & adjusting without taking down shutters of size exc 1.00 sqm and n exc 2.00 sqm complete all as specified and directed.
M&L rolled sections as in framing for cladding, door chowkats, glazing and the like fixed with angle cleats and connecting plates, etc. complete all as specified and directed.
M&L 300mm Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixedcomplete all as specified and directed.
S & F 30 mm thick flush shutters, board solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F 30 mm thick 2nd class hard wood (Hollock/Sal/Bijasal), glazed skeleton door shutters open rebated and prepare to receive glass, gauge (without sash bars) edges of framing plain chamfered or rounded, fitted with cut including mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I section 8, clause No 8.24 (a) complete all as specified and directed.
S&F solid PVC frame of size 50x47mm made out of 5mm plain coloured PVC sheet reinforced with MS square tube supplying & fixing in opening as specified in clause No. 8B.3 and shown in drawing of SSR 2020 respectively and as directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rail. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement complete all as specified and directed.
S&F in repair 18 mm thick Celuka ply of grade 1 quality of one side pre-laminated and other side plain white colour to make kitchen cabinet/drawer shutters complete as per specification and as directed.
S&F ball catches with 8mm dia steel ball, and brass body and striking plate including letting in complete as per specification and as directed.
S&F 75 mm long medium weight, cold rolled mild steel Butt hinges complete all as specified and directed.
S&F 50mm dia, polished, hard wood knobs fixed with screws complete as per specification and as directed.
S&F 100 mm long medium weight, cold rolled mild steel Butt hinges complete all as specified and directed.
S&F 150 mm long aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F 150 mm long aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F galvanized mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned stacks, or galvanized wire staples complete all as specified and directed.
S & F in repair galvanized mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned stacks, or galvanized wire staples complete all as specified and directed
S&F in repairs mild steel PVC coated drapery rods, 25mm internal diameter 2mm thick web including decoratine type brackets, side caps and PVC curtain rings 8 Nos per RM including fixing arrangement with drilling holes in walls, brackets etc complete all as specified and directed.
M & L for preparation of old wooden surface of any discription not otherwise discribed over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (Ordinary tint) over a coat of pink primer complete all as specified and directed.
S&F in repairs 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed.
M&L 75mm thick PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) for finished even and fair complete all as specified and as directed.
M&L for Chequered cement concrete tiles 300 x 300m x 25mm thick, set, jointed and pointed in near cement slurry in floors with grey cement and pigment over & including screed bed 15 mm thick in CM 1:4 complete all as specified and as directed.
Demolition of cement concrete (reinforced) in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed.
M&L PCC 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate) as in plinth protection ( 75 mm thick ) laying in alternate ways finished even and fair without using extra cement all as specified including filled joint with bitumin mastic complete all as specified and directed.
M&L PCC flooring 100mm thick 1:2:4, type B1 (using 20mm graded stone aggregate) complete all as specified and directed.
Mild steel TMT bars 10 mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Ditto as item No. 98 above but 5mm dia and over upto and incl 10mm dia in stirrups, spacers and binders
Use & waste of formwork to soffits of slab concrete exceeding 20 cm wide complete all as specified and directed.
Use & waste of formwork to sides of slab concrete not exceeding 20 cm wide complete all as specified and directed.
M&L RCC Nominal mix 1:2:4, type B-1 (using 20mm graded stone aggregate) as in slabs supported on walls and in shelves and the like complete all as specifed and directed.
M & L cutting holes into or through brick wall built in cement mortar exc one brick but n.exc two bricks and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1(using 20mm graded stone aggregate) as required complete all as specified and directed.
S&F aluminium frame/shutter for doors, windows, ventilators and partitions with powder coated (Thickness of powder coating not less than 50 Micron) one or more rebates including joining cleat for fixing etc.complete all as specified and directed. Note : Rate include for neoprene beading, screws etc. Glass pane, particle board insert shall be measured & paid separately.
S&F in repairs double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty, ISI marked, complete all as specified & directed.
S&F in repairs door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg, aluminium (extruded section) body, ISI marked, complete all as specified & directed.
S&F 5.50 mm thick tinted sheet glass with necessary jointing cleats, glazing clips, rubber packing & anodised aluminium snap beading complete all as specified and directed. .
S&F in repairs 100 mm long Mortice latch with four levers (vertical type), aluminium body and fixed complete all as specified & directed.
M&L 12mm thick veneered partcle board exterior grade faced with decorative veneer on both faces including fixing with rubber gasket complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc or insulation boards/ slabs/ blankets any thickness including cover filletts complete all as specified and as directed.
S&F GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre. size of grid 605 mm x 605mm complete all as specified and as directed.
S&F calcium silicate board 6 mm thick if siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 x 600mm grid complete all as specified and as directed.
S&F PVC sheet wall panelling (wood grains) of thickness 5mm struck on interframe work on 50mm wide strip and 5mm thick PVC sheet the the strip should have a groove of 6mm width and 1mm depth in their centre for sinking the head of screw to the wall vertically the PVC strip shall be fixed to the wall using 65mm long MS screw not more than 200mm C/C throgh the groove in the strip by using PVC fastener complete all as specified and as directed. Note: PVC fillets & PVC strips shall be measured & paid separately
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame complete all as specified and directed.
S&F in repair hand rails, half round or other steel section hand-rail straight portion, drilled and countersunk for balusters running bars, including embedding in concrete and screwing etc. posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and as directed.
S&F in repairs galvanized, 2 strand, steel barbed wire, 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails, straining bolts including securing or tying at crossing with and provision of galvanized MS wire staples or steel pins etc as specified. (each line wire to be measured). complete all as specified and directed
M&L in repair collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and as directed.
Taking down carefully copper/aluminium point wiring on batten/ PVC conduit (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, including removal and making good disturbed surfaces of walls, ceilings etc by cement/ colour /plaster to match with the existing location spot complete all as specified & directed.
M&L for point wiring concealed type with 1.50sqmm PVC FRLS insulated, unsheathed, single core, multi stranded copper conductor cable 1100 volts grade including 1.5sqmm FRLS PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor drawn in and including rigid PVC conduit of suitable size but not less than 20mm dia with its accessories, sunken type pressed steel terminal box made of 1.2mm thick MS sheet/ anodised steel box painted with one coat of red oxide primer including 3.0 mm thick ISI marked plastic laminated sheet cover for fixing switches/ socket/regulators etc including cutting chases in wall as per standard engineering practice & making good the disturbed surfaces to match with existing for the one light/ fan/street/bell point controlled by 1 one way switch 5/6 Amps complete all as specified & directed.
All as per item No-119 here in before but One socket outlet 5/6 Amps on independent bd controlled by one switch complete all as specified & directed.
All as per item No-119 here in before but One socket outlet 5/6 Amps controlled by one switch on same board with other switches complete all as specified & directed.
All as per item No-119 here in before but one socket out let 3/5 pin, 5/6 Amps controlled by one 1way switch on independent board but not below the switch board of light points in same vertical plane complete all as specified & directed.
All as per item No-119 here in before but using 2.5 sqmm PVC FRLS insulated stranded copper cunductor cable and for one socket out let 3/6 pin, 15/16 Amps controlled by one 1 way switch on independent board complete all as specified & directed. NOTE-For item no 119 to 123 -: (i)The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillers etc for concealing the conduits to required depth & making good the disturbed surfaces in cement mortar 1:4 including finishing the surface to match with the existing surface.The portion of point wiring at RCC Coloumns / Beams / Ceilings etc shall be in surface conduit of suitable size fixed on surface with using PVC rawl plug and provision of covering terminal boxes/junction boxes of any shape and size with 3 mm thick bakelight laminated sheet fixed with suitable GI screws and cup washers. (ii) Fittings like switches, sockets, regulators, lamp holders, light foittings shall be measured and paid for separately under appropriate item of schedule A. (iii)The size of conduits shall be determined on permissible no of runs of wires as specified in SSR part-I clause 19.125 (B).However minimum size of conduit shall be 20 mm dia (medium grade)
S&F switch piano, flush type, single pole, 5/6 Amps one way, 230 volts complete all as specified and directed. Make: Anchor Cat No.38058 or equivalent as approved by GE.
S&F switch piano, flush type, single pole, 15/16 Amps one way, 230 volts complete all as specified and directed. Make: Anchor Cat No.39991 or equivalent as approved by GE.
S&F socket outlet, 5/6 Amps, flush type, 5 pin 230 volts complete all as specified and directed. Make: Anchor Cat No.38320 or equivalent as approved by GE.
S&F socket outlet, multi-purpose 3 pin 5/6 Amps and 3 pin 15/16 Amps complete all as specified and directed. Make: Anchor Cat No.39994 or equivalent as approved by GE.
S&F for ceiling rose surface bakelite 62.5 x 25 mm size 3 terminals complete all as specified and directed. Make -Anchor CAT Part No-39072 or equivalent as approved by GE.
S&F switch, bell push button, single pole, 5/6 Amps, one way, 230 Volts complete all as specified and directed. Make -Anchor CAT Part No-38047 or equivalent as approved by GE.
S&F electrical bell model city ding dong (Ding dong type) AC, 230 Volts complete all as specified & directed. Make:- Anchor / Cona / Plaza as approved by GE.
S&F lamp holder insulated body with back plate for batten fitting complete all as specified and directed. Make: Anchor Cat No. 39797/ 39800 or equivalent as approved by GE.
S&F rotory stepped type electronic fan regulator mini flush type 100 watt 230 Volts complete all as specified & directed. Make: Anchor Cat No.38284/38660 or equivalent as approved by GE.
S&F in replacement, single pole and neutral sheet metal enclosure (AC box) with a two pin & earth plug and socket with one no. MCB SP of capacity 20 Amps 240 volts IK-08 As per IEC 61439-3 complete all as specified & directed. Make:- Legrand cat part No- 5078 11 & 4085 93 or equivalent model of make Siemens/ Schneider as approved by GE.
S&F in replacement of LED Bulb 15 watt, single phase, 230 Volts AC supply suitable for lamp holder complete all as specified and directed. Make :- Havells cat part No-LHLDDEEEML8R015 or equivalent Model of Philips/Bajaj/CG/ Wipro as approved by GE.
S&F in replacement of surface/wall mounting LED batten 20 watt luminaire having extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver with mounting accessories complete with lamp holders fixed to wall/ ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire of size 0.75 sqmm from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No-ENDURALINEARNEOBS20WLED865SPCWH or equivalent Model of Philips/Bajaj/CG as approved by GE.
S&F in replacement of surface/ ceiling mounting type 34 watt LED luminaire PLUTO NEO PENAL 2X2 environmental friendly new generation aesthetically ultra modern recess mounting with high brightness SMD LEDs as light source with reflector cover electronic driver, connector block etc with internally prewired fixed to ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire of size 0.75 sqmm from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No- PLR34WLED857S or equivalent model of make ,Philips/Bajaj/ Crompton Greaves as approved by GE.
S&F in replacement of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Havells cat part No- LHECDEFOIH1W028 or equivalent model of make ,Philips/Bajaj/ Crompton Greaves as approved by GE.
S&F in replacement of outdoor security light LED 36/40 watt luminaire IP 65/66 protection polyster powder coated with pressure die cast aluminium housing and robust construction with reflector cover pre anodised and flat white high transmission acrylic cover or toughened glass, natural white type with electronic driver, connector block etc with internally prewired fixed to building with and including 1.20M long bracket made out of 40mm dia light grade GI pipe bent to shape & providing clamps 2 Nos made out of 50 x 6 mm Flat iron/MS clamps & 12mm dia bolts, nuts & washers etc and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No- ENDURAPEARLNEOSL40WLED757PASYTOPC,Phillips cat part no BRP052 LED 036 CW HP SLA FG S1 PSU GR or equivalent as approved by GE.
S&F in replacement of LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified & directed.
S&F in replacement of NEW GENERATION POST TOP energy saving envirmental friendly long life 35 watt LED luminaire light fitting, IP 65 protection with reflector cover electronic driver, connector block etc with internally prewired fixed to brcket on gate with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No-RUBYPT35WLED757PSYMTOPC or equivalent model of make Philips/Bajaj/ Crompton Greaves as approved by GE.
S&F in replacement, surface round mounting type 12/15 watt LED luminaire with reflector cover electronic driver, connector block etc with internally prewired fixed to ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No-EDGEPRORDDLR12WLED857S or equivalent as approved by GE.
S&F in replacement, surface square mounting type 12 watt LED luminaire with reflector cover electronic driver, connector block etc with internally prewired fixed to ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No-EDGEPROSQDLR12WLED857S or equivalent model of make Philips/Bajaj/ Crompton Greaves as approved by GE.
S&F in replacement surface mounting type bulkhead 10 watt LED luminaire ENDURA RUGBY NEO IP 65 environmental friendly, altra modern energy saving , decorative oval comprising of high brightness LEDs, connector block etc with internally prewired fixed to wall with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No- Cat part No FT10WLED857SSYMBOPC or equivalent model of make Philips/ Bajaj/ Crompton Greaves as approved by GE.
Taking down care fully sub main wiring / service connections of any size including batten/ conduit, and making good the disturbed surfaces of wall/ floor complete all as specified and as directed.
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 6.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 4.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
M&L for sub main wiring with four runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 10.0 sqmm drawn in and including rigid PVC conduit medium grade of suitable size but not less than 25mm dia with its accessories, concealed type, including two run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 10.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Notes :- Finished sub main wiring with four runs of 10.0 sqmm cable & two run of 10.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
Taking down distribution boards any size any type including MCB TPN/SPN/SP etc and making good the disturbed surfaces complete all as specified and as directed.
S&F MCB DB vertical type 4 way VTPN sheet metal enclosure 415 volts with 100 Amp fully insulated standard copper bus bar for each face & surrounded with neutral bars and two common neutral bar, two earth bar including cable ties for cable manegement suitable for housing MCCB TPN 415 Volts as incommer, IP-43, IK-09 as per IEC 61439-3 with metal doors all enclosed on standard steel sheet flush mouting type double door factory fabricated complete without MCB & MCCB but with enclosue blank plate complete all as specified and directed . Make:- Legrand CAT No.507725 or equivalent model of make Siemens/ Schneider as approved by GE.
S&F MCB DB 4 way sheet metal enclosure triple pole and neutral 415 volts with 100 Amp standard copper bus bar IP-43, IK-09 with metal doors of suitable size and common neutral link and earth bar all enclosed on standard steel sheet flush mouting type double door factory fabricated complete as per IEC 61439-3 without MCB but with enclosue blank plate complete all as specified and directed . Make:- Legrand CAT No.5076 70 or equivalent model of make Siemens/ Schneider as approved by GE.
S&F MCB DB sheet metal enclosure factory fabricated double door SPN 8 way with 100 amps rated copper bus bar 240 volts IP-43, IK-09 with metal doorscomplete all as specified and directed. Make:- Legrand Cat Part No. 5076 11 or equivalent model of make Siemens/ Schneider as approved by GE.
S&F MCB DB sheet metal enclosure factory fabricated double door SPN 4 way with 100 amps rated copper bus bar 240 volts IP-43, IK-09 with metal doorscomplete all as specified and directed. Make:- Legrand Cat Part No. 5076 10 or equivalent model of make Siemens/ Schneider as approved by GE.
S&F MCB DB sheet metal enclosure factory fabricated singal door SPN 2 way with 100 amps rated copper rated bus bar 240 volts IP-43, IK-09 complete all as specified and directed. Make:- Legrand Cat Part No. 507610 or equivalent model of make Siemens/ Schneider as approved by GE.
S&F MCCB 4 pole 100 to 125 Amp Icu 16 Kilo Amp and Ics 100% of Icu with adjustable 70% to 100% and thermal magnetic release suitable for fixing in VTPN DB. Make : Legrand cat part 4200 15 to 4200 16 or equivalent model of make Siemens/ Schneider as approved by GE.
S&F Isolator TPN, 4 Pole, 415 Volts, 50 Hz AC Supply , 100 Amps, IP-20 as per IEC 60947-3 ISI marked complete all as specified & directed. Make:- Legrand CAT No. 406522 or equivalent model of make Siemens/ Schneider as approved by GE.
S&F Isolator SPN , 63 Amps, 240 volts, 50Hz, IP-20 as per IEC 60947-3 ISI marked complete all as specified & directed. Make:- Legrand CAT No. 4065 02 or equivalent model of make ABB/ L&T/ Schneider as approved by GE.
S&F Isolator SPN, 40 Amps, 240 volts, 50Hz, IP-20 as per IEC 60947-3 ISI marked complete all as specified & directed. Make:- Legrand CAT No. 406501 or equivalent model of make ABB/ L&T/ Schneider as approved by GE.
S&F MCB SP, 40 to 63 Amps, 'C' Curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed. Make:- Legrand CAT No. 4085 96 to 4085 98 or equivalent model of make Siemens/ Schneider as approved by GE.
S&F MCB SP, 6 to 32 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed. Make:- Legrand CAT No. 4085 87 to 4085 95 or equivalent model of make Siemens/ Schneider as approved by GE.
M&L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm size, buried directly in ground (earth pit not less than 2.25 M deep below normal ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to and including galvanised steel earth lead wire of 4 mm dia, including 15 mm bore GI light grade protection pipe upto 1 Mtr above the floor level of the buildings where main switch, DB etc, situated, earth lead wire connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150 mm thick alternate layers of charcoal or cock dust mixed with common salt 20 mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) cover of precast RCC 1:2:4 type B-1(using 20 mm graded stone aggregate) duly reinforced with 8 mm formed or twisted bars @ 100 mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/ Looose soil and deposited the surplus soil to a distance not exceeding 50 mtr away from starting point, all as per electrical plate no:3 of SSR part-1 .
M&L for electrically disconnecting and taking down existing ceiling/Exhaust fans from any hight or in any position from existing bldg and keeping in safe custody for reuse at site after necessary repare/ servicing & painting with one coat of synthetic enable paint and writing of MES/identification No. of fans and re hanging/ re-fixing in original position but including replacement of three cor flexible copper conductor cable from ceiling rose to fan connector block of soze 0.75 Sqmm and hanging fan clamps, nuts, bolts and rubber reel bush etc & testing for proper functioning complete all as specified and as directed.
Supply & Laying, testing, cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 volt grade, with stranded aluminium conductor of size 35 Sqmm 4 core including taking out existing cable compele all as specified and as directed.
Supply & Laying, testing, cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 volt grade, with stranded aluminium conductor of size 10 Sqmm 2 core including taking out existing cable compele all as specified and as directed.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in soft/loose/ soil for taking out/laying CI/GI pipe line and getting out soft/loose soil complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and as directed.
Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified and as directed.
Supplying and laying un-rainforced precast concrete cable cover LV type-I flat size 250 mm x 150 mm x 40 mm in trenches for protection of cable complete all as specified and as directed.
M&L for sand cushioning dry fine for cable cushioning below and above the cable complete all as directed & directed.
Supply and fixing GI Pipe 40mm light grade, for cable protection laid in trench under road or path or fixed on pole or wall with clamps with all fittings complete all as specified and as directed,.
PD GUPTA AND COMPANY
VISHESH BUILDERS
M/s K S Builders
MOHAN LAL GUPTA
SHRI RADHAYSHYAM JHA
Asha Construction
Balaji Associates
M/S SHRINATH CONTRACTION
N.K. ENTERPRISES
Om shri sain ram enterprises
M/s Tomar Builders
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .