EE PHE Maintenance Division
Rajasv Colony Dashara Maidan Ujjain
Annual Maintenance Incoming Panel at Gaughat Filter Pump House.
2023_UAD_276798_2
PHE/E-TENDER 37/2023
Open Tender
Civil Works - Water Works
Item Rate
365 days
Ujjain
Please refer Tender Document
4 documents required · 4 mandatory
₹2,000
₹11,670
5 Jan 2024
16 Jun 2023
3 Jul 2023
16 Jun 2023
30 Jun 2023
16 Jun 2023
Amount
Providing and fixing on delay timer relay for controling Motor 0-10 time fraction, 3.5 SMF, 440V installed in starter panel of Raw water LT motor
Providing and fixing 8 Pin 240A-5 , 20/0-MPC type control relay for starter panel of motor
Providing and fixing GIC L &t make 440V three phase with 65+-10VAC, operating time 2sec release time 7 sec single phasing preventer for Starter panel
Supplying of ISI Marked and approved make of Moulded Case Circuit Breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, AC supply with respective interrupting capacity (KA) at 415 Volts cited against their range standard conforming to IS - 8828
Current Rating -630 Amps & Adjustable: 70% -100% thermal & 5- 10 times magnetic setting
Current Rating -400 Amps & Adjustable: 70% -100% thermal & 5- 10 times magnetic setting
Current Rating -200 Amps & Adjustable: 70% -100% thermal & 5- 10 times magnetic setting
Current Rating -125 Amps & 70% -100% adjustable 25KA rating
Current Rating -25 to100 Amps & 70% -100% adjustable 25KA, TP MCCB
63 AMP, 10kA, TP MCB
Metering CT 400/5A, 10VA/1.0
Fiber Kit Kat fuse Base with Fuse Link 20Amp
Fiber Kit Kat fuse Base with Fuse Link 32Amp
Ampere Meter
Digital Volt Meter
Providing high tensile 3/8" size nut bolt with GI washer
RYB electric tap roll
Supplying and fixing cramping type Alum. lugs as per I.S.S. Specification suitable for following size of cable with Al./ Copper solid/ stranded conductor evently cramped with high/pressure tool and connected to switch gear/ Bus/ M.C.C.B./ M.C.B. etc. as required complete. For Conductor Size-
Providing of ML-12/10 Contactor of L & T make of 200 A & 415 Volt for raw water pumps Control Pannel.
Providing of ML- 6 Contactor of L & T make of 200 A & 415 Volt for raw water pumps Control Pannel.
Providing of ML- 3 Contactor of L & T make of 200 A & 415 Volt for raw water pumps Control Pannel.
Providing of ML-6 Contactor Kit
Labour Charges for Fitting of ML- 6 Contractor i/c dismantling of old damge contractor from control pannel
Labour Charges for Fitting of ML- 3 Contactor i/c dismantling of old damged contactor from control pannel raw control Pannel
Labour Charges for Fitting of Contactor Kit of ML-10, ML-6 contactor i/c removing of old damge Kit.
Opening 3200AMP main incomer No 2 ACB from back disconnect bus-bar from ACB, opening ACB for Complete servicing in presence of Company Service engineer, Scrapping all the metal part of ACB reconnect ACB with panel bus bar and after completion of work testing on load and trpping
Providing and fixing Gang Operated Gang Switches used to perform Make and Break operation in a sequential way by rotating the switch to different positions to Increase capacity of circuits by ganging in serial or parallel operations for different circuit capacity are used to connect two different circuits from one source. These are used to operate two different circuits with different number of inputs and outputs (potential free contacts) are used to connect two different circuits from two different sources with two different operating voltages or any other incompatible lines. All contacts by default are “Break Before Make” (BBM) type to avoid overlapping of different circuits. However, for overlapping changeover contacts. “Make Before Break” (MBB) type are offered against specific requirements.
Labor Charge for fitting Material in old panel every time installed at Gaughat Filter Plant No 3 All the T & P to be arrange by contactor
Providing & fixing shunt release for 3200Amp main incoming ACB for both 2MVA transformer incmoing having following specification - type EA volt-24/48 V DC of L & T make
Providing & fixing under voltage (UV) release for 3200Amp main incoming ACB for both 2MVA transformer incmoing having following specification - type MV volt-24/48 V DC of L & T make
Opening ACB from back disconnect bus-bar from ACB, opening ACB for Complete servicing in presence of Company Service engineer, reconnect ACB with panel bus bar and after completion of work testing on load and trpping
Providing & fixing shunt release for 1250 Amp main incoming ACB for both 2MVA transformer incmoing having following specification - type EA volt-24/48 V DC of L & T make
Providing & fixing under voltage (UV) release for 1250 Amp main incoming ACB for both 2MVA transformer incmoing having following specification - type MV volt-24/48 V DC of L & T make
Opening ACB from back disconnect bus-bar from ACB, opening ACB for Complete servicing in presence of Company Service engineer, reconnect ACB with panel bus bar and after completion of work testing on load and trpping
Providing and fixing protection release having following specification - microprocessor based, SR 18G type, Rated operational voltage (V), 50/60Hz 415 (V), 50/60Hz Ue Rated insulation voltage (V), 50/60Hz 1000 (V), 50/60Hz Ui
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .