Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.9 CrAccepted-AOC | ₹3.9 Cr Quoted ₹4.0 Cr | 1 | Accepted-AOC Being L1 |
| 2 | 2₹4.9 Cr+₹94.7 L (23.9%)Rejected-Finance | ₹4.9 Cr+₹94.7 L (23.9%) | 2 | Rejected-Finance Being L2 |
Tender Value
₹3.4 Cr
EMD Value
₹4.1 L
Closing Date
16 Feb 2022, 6:00 pmClosed
CE AF Shillong Zone
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
COMPLETION OF INCOMPLETE WORK OF PROVN OF AUDITORIUM AT AF STN BORJHAR
2021_MES_490350_2
88318/BOR/RC/E8
Open Tender
Civil Works
Lump-sum
270 days
GE (AF) Borjhar
As per tender documents
8 documents required · 8 mandatory
₹2,000
GE (AF) Borjhar
₹4.1 L
Yes
7 Mar 2022
12 Jan 2022
18 Feb 2022
12 Jan 2022
16 Feb 2022
2 Feb 2022
Amount
SCHEDULE "A" Part - I (BUILDING/ STRUCTURE WORKS)
Construction of incomplete/ balance items of works of Auditorium building all as specified and as shown on drawings. Note:- (i) The detail of completed works are furnished as Appx 'A' to BOQ for purpose of guidance of tenderer only. (ii) Please note that NO claim whatsoever on any account of any errors/ inaccurancies on completed quantities given in Appx 'A' inserted by MES shall be entertained at a later. (iii) The tenderer shall workout incomplete/ balance items of works independently on visiting the site personally and quote their lumpsum amount accordingly for completion of buildings all as shown in drawings and as specified.
Construction of incomplete/ balance items of works of Pump house building, single storey framed structure all as specified and as shown on drawings. Note:- (i) The detail of completed works are furnished as Appx 'B' to BOQ for purpose of guidance of tenderer only. (ii) Please note that NO claim whatsoever on any account of any errors/ inaccurancies on completed quantities given in Appx 'B' inserted by MES shall be entertained at a later. (iii) The tenderer shall workout incomplete/ balance items of works independently on visiting the site personally and quote their lumpsum amount accordingly for completion of buildings all as shown in drawings and as specified.
Construction of incomplete/ balance items of works of RCC under ground sump of 50000 Ltrs capacity all as specified and as shown on drawings. Note:- (i) The detail of completed works are furnished as Appx 'C' to BOQ for purpose of guidance of tenderer only. (ii) Please note that NO claim whatsoever on any account of any errors/ inaccurancies on completed quantities given in Appx 'C' inserted by MES shall be entertained at a later. (iii) The tenderer shall workout incomplete/ balance items of works independently on visiting the site personally and quote their lumpsum amount accordingly for completion of buildings all as shown in drawings and as specified.
Total amount of Sch 'A' Part-II (EARTH WORK AND SITE CLEARENCE) Details of prepriced Schedule is given in tender documents
Total amount of Sch 'A' Part-III (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents
Total amount of Sch 'A' Part-IV (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents
Total amount of Sch 'A' Part-V (ROAD/ PATH/HARD STANDING) Details of prepriced Schedule is given in tender documents
Total amount of Sch 'A' Part-VI (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents
Total amount of Sch 'A' Part-VII (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents
Total amount of Sch 'A' Part-VIII (COMPOUND WALL/ GATE/ FENCING) Details of prepriced Schedule is given in tender documents
Total amount of Sch 'A' Part-IX (EXTERNAL WATER SUPPLY). Details of prepriced Schedule is given in tender documents
Total amount of Sch 'A' Part-X (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents
Total amount of Sch 'A' Part-XI (FIRE DETECTION AND ALARM SYSTEM) Details of prepriced Schedule is given in tender documents
Total amount of Sch 'A' Part-XII (FIRE FIGHTING ) Details of prepriced Schedule is given in tender documents
Total amount of Sch 'A' Part-XIII (LIGHTNING PROTECTION). Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART -XIV (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES.
Material and labour for bringing approved earth from outside MoD Land, filling in pavings / embankment, spreading in layers n.exc. 25 cm thick, watering, ramming, rolling and compacting with power roller 8 to 10 tonne and finishing to required gradient and shape complete all as specified and directed. Note: (i) Payment shall be made for solid quantity arrived after consolidation. (ii) 10% deduction shall be made from finished embankment quantity for bulkage.
S&F 15mm dia bore angle cock brass CP high pressure with capstan head long shank screwed down complete all as specified.
S&F LED flood light luminaire 160 Watt with secondary optics mad in pressure die cast housing and heat sink in aluminium extrusion with IP 66 protection including necessary connection complete all as directed. Make:- Bajaj cat No BARFEG 160 W LED or equivalent from make list as specified in PS.
S&F Double sided LED signage with built in battery back up for 2 hours complete all as specified and directed. Make Bajaj cat part No. 'BESL 03 LED DSD WBB Red' or equivalent from make list as specified in PS.
S&F 1200 sweep ceilling fan and connecting up cable from celling rose or connector to fan complete all as specified.
S&F Exhaust fan 300 mm sweep complete all as specified.
S&F MCBs SPN 32A ("C" curve) capacity complete with cable connection with copper lugs complete all as specified and as directed.
S&F MCBs SPN 40A to 63A ("C" curve) capacity complete with cable connection with copper lugs complete all as specified and as directed.
S&F MCBs SP 6 to 32A ("C" curve) capacity complete with cable connection with copper lugs complete all as specified and as directed.
S&F Three phase kwh meter 5-40A capacity without optical port with LCD display with all electrical connection with copper wire complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI wire 4.0 mm dia up to 7.5 mtr by means of nuts, bolts, check nuts, washers of galvanised iron/steel all as shown in electric plate No 3 all as specified and indicated complete with funnel, charcole, dust, salt etc and GI protection pipe, light grade 40 mm bore and GI watering pipe 20 mm bore light grade, 50 mm thick precast RCC M-15 (nominal mix) cover reinforced with XPM weight not less than 4 kg/Sqm with suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover, PCC type C2(1:3:6) (nominal mix) pit, excavation and earth work in any type of soil and connected all as specified and as directed by Engineer-in-Charge.
Construction of brick masonry septic tank for 100 users complete all as shown in drawing and specified.
Construction of Soakage well suitable for 100 users complete all as shown in drawings and as specified .
Supply and install Pumping sets centrifugal, electric driven of capacity 0.5 HP complete with PCC foundation all as specified and as directed.
Supply and install CI sluice valve flanged of class 1.0 PN complete of size 80 mm dia all as specified and as directed.
Construction of brick masonry valve pit/chamber of internal dimension 900 mm x 900 mm x 860 mm with old size sub class 'B' bricks in CM (1:4) and 10 mm thick plastering in CM (1:4), 150 mm thick PCC 1:3:6 Type C2 (using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC 1:3:6 type C1 (using 20 mm graded broken stone aggregate) as in bedding and coping MS frame with 40 mm x 40 mm x 6 mm angle iron 4 mm thick MS sheet cover plate with locking arrangements, hinges, lifting arrangement with hook made of 10 mm dia MS rod, applying two coats of synthetic enamel paints over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to surfaces) excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and as directed.
Cutting existing steel tubing for alteration or addition of size 80 mm dia.
M&L LT feeder pillar box (CPRI approved) made out of CRCA sheet 3.15 mm thick of size 1.0mx0.75m x 0.45m complete with 4 Nos aluminium bus bar and control system as follows:- (a) Incoming - MCB TPN 40 Amps 10 KA rating - 01 Nos. (b) Outing - (i) MCB SPN, 10 Amps, 10 KA rating 240 volts - 03 nos (ii) DOL starter single phase 1 HP capacity - 02 Nos
S & F Pressure die cast aluminium housing 45 watt LED street light luminaries with IP 66 protection including necessary electrical connection complete all as directed. Bajaj Cat No. BRTFG 45W LED or equivalent makes given in PS.
S & F Pressure die cast aluminium housing 25 watt LED street light luminaries with IP 66 protection including necessary electrical connection complete all as directed. Bajaj Cat No. BRLEP 25W LED or equivalent makes given in PS.
Supply and fixing IP 65 thermoplastic-polycarbonate pole box with terminal and MCB which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology.
Supply and fixing Post top lantern 40 Watt made in cast aluminium spigot housing with decorative opal acrylic diffuser and IP 65 protection including necessary connection complete all as directed. Make - Bajaj Cat No. BGCL 40W LED or equivalent makes given in PS.
Supply and fixing bracket for street light fittings of any size made out of GI Pipe medium grade 40 mm dia 1.25 mtr length bend to required size and shape including provision of clamps.
M&L for Earthing complete with Copper earth plate electrode of size 600x600x3.15 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to copper earth strip of size 25x3.15 mm thick up to 7.5 mtr by means of nuts, bolts, check nuts, washers of tinned brass, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with 40mm thick precast RCC (1:1.5:3) type A-1 cover slab, reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (light grade) for watering,including charcoal or coke and salt in alternate layers and filling earth pit with fresh vegetable soil below copper plate and above upto ground level as required and necessary earth work in any type of soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion, complete all as specified and directed.
Supply and installation of silent Diesel Engine driven generating set 415 volts, 3 phase, 4 wire engine as per IS : 1000/10002 and alternator as per IS : 13364 complete of capacity 160 KVA with relay panel for automatic starting on mains failure control panel having meters, sound proof canopy and foundation all as specified and as directed.
Supply and installation water cooler Electric driven (single phase), having approx storage capacity of 40 liters and nominal cooling capacity of 40 liters per hour.
Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 1.0 KVA.
Voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type and designed for input variation between 340V to 460V with output voltage stabilized at 415V with accuracy of + 2.5% and speed of correction 8 volts per second and of capacity 50.0 KVA.
Supply, installation, commissioning and testing VRF type air cooled unit 30 HP (i.e. 24 TR) comprising the following :- (a) Supply, installation, commissioning and testing of modular type outdoor units equipped with highly efficient inverter compreesors, eco-friendly refrigerant R410a special acryl precoated heat exchanger , low noise condensor fan, auto check function for connection error, auto address setting, with capacity 30 HP (i.e. 24 TR) including foundation as per manufactuerer's specification - 02 Nos. (b) Supply, installation, commissioning and testing of indoor units equiped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, outer cabinet, drain pan, insulation, pipe connections etc. for MSP Duct Units with Corded Remote Controller of capacity 4.0 TR - 14 Nos. (c) Supply and installation of imported fittings Y-joints and headers etc. - 01 Job. (d) Supply and fixing Interconnecting refrigerant pipe work with (19mm/13mm thick) closed cell elastomeric nitrile rubber/XLPE tubular insulation between each set of indoor and outdoor units as per specificaitons. All piping inside the room shall be properly supported with MS hanger:- (i) Suction Line (on actual measurement) - 45 RM. (ii) Liquid Line ((on actual measurement) - 45 RM. (e) Gas Charging R410a - 10 Kg. (f) Supply and fixing Rigid PVC piping 25 mm dia complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation - 50 RM. (g) Suuply and fixing control cum transmission wiring of 2 core x 1.5 Sqmm copper conductor in suitable PVC conduits between indoor and outdoor unit - 60 RM. (h) Outdoor stands (Floor mounted ) with vibration pads - 02 Nos. (j) Supply and installation of Air Distribution System :- (i) 24 G GSS ducting with Threaded Rods, Flanges etc. - 30 Sqm. (ii) Supply Air Griller/Diffusers with VCD - 02 Sqm. (iii) Return Air Griller/Diffusers without VCD - 02 Sqm. (k) Supply and installation of following insulations :- (i) Thermal Insulation with 19mm thick Foil Faced XLPE - 30 Sqm. (ii) Acoustic Insulation with 12mm thick Glass Wool- 03 Sqm. Note :-Cost of minor items not specifically mentioned above and required for completion of AC installation is deemed to be included in the quoted rate.
M&L for automatic cum detection, fire alarm 2 loop control panel analogue addressable complying with 99 detections and modules and upto 200 detections and modules , microprocessor base modular expandable panel with window type annunciation to indicate fire fault, LED lamps for visual indication, audio alarm with push button for acknowledge test reset complete with power supply of 24 DC , suitable AH and 230 v AC and back with a main free battery backup system with (a) Repeater driver board (b) communication board (c )Software and graphics (d) Ni-Ci batteries and charger (e)Amplifier Cord
M&L Repeater Annunciator panel with mimic panel.
Supply laying of cable of size 1.5 sqm, 2 core FR grade, copper conductor for sensor all as specified and as directed.
M&L Rigid steel conduit fixed to wall, 25 mm dia all as specified and as directed.
M&L Air Circulator fans 230 volts single phase oscillating 600 mm sweep suitable for wall mounting.
M&L Earthing complete with Copper earth plate electrode of size 600x600x3.15 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to copper earth strip of size 20x3.15 mm thick up to 7.5 mtr by means of nuts, bolts, check nuts, washers of tinned brass, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with 40mm thick precast RCC (1:1.5:3) type A-1 cover slab, reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (light grade) for watering,including charcoal or coke and salt in alternate layers and filling earth pit with fresh vegetable soil below copper plate and above upto ground level as required and necessary earth work in any type of soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion, complete all as specified and directed.
M&L 150 mm dia Cast Iron pipe with spigot and socketed ends centrifugally cast, class B, including all fittings.
M&L MS ERW pipe including all fittings of bore 150 mm as per IS 3589 and thickness 6 mm.
All as per item No 14.38 here-in-before but size 200 mm
Sluice Valve class PN 1.6 suitable for 150 mm dia.
Supply and fix hydrant landing valve type A (double head out let) of 63 mm dia of size confirming to IS 5290.
Supply and fix fire hydrant post with proven of single outlet confirming to IS-908.
Supply and fix 63 mm dia 15 mtr long hose confirming to IS-636 compete with male and female coupling confirming to IS-903..
Supply and fix branch pipe and nozzle for 20 mm dia hose reel confirming to IS-8090.
Supply and fix hose reel of 20 mm and 30 mtr length confirming to IS-5132.
Supply and fix hose box for keeping 2 Nos. hose pipe of length 15 mtr, branch pipe nozzle coupling etc. of MS Sheet of thickness 2 mm.
Supply and fix hose box for 20 mm dia and 30 mtr length complete with coupling branch pipe and nozzle.
Supply and fixing Air release valve 150 mm
Construction of brick masonry valve pit/chamber of internal dimension 1000 mm x 1000 mm x 1000 mm with old size sub class 'B' bricks in CM (1:4) and 10 mm thick plastering in CM (1:4), 150 mm thick PCC 1:3:6 Type C2 (using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC 1:3:6 type C1 (using 20 mm graded broken stone aggregate) as in bedding and coping MS frame with 40 mm x 40 mm x 6 mm angle iron 4 mm thick MS sheet cover plate with locking arrangements, hinges, lifting arrangement with hook made of 10 mm dia MS rod, applying two coats of synthetic enamel paints over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to surfaces) excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and as directed.
Supply and fixing water stored pressure extinguisher of 9 Ltr capacity.
Supply and fixing Dry chemical powder (ABC) Extinguisher of 5 Kg capacity
S&F light weight squeze grip type CO2 Extinguisher
S&F Mechanical foam extinguisher 9 Ltr
S&F Dry chemical powder (ABC) Extingusher trolly mounted 25 kg.
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanized steel earthing strip 25x4mm upto 7.5m from testing point fixed by means of galvanized iron or steel bolts nuts check nuts and washers, GI earth wire protected by 40mm bore light grade galvanized iron pipe and other end connected to earthing test point including funnel with watering pipe of 20mm bore medium grade galvanized iron, wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness)all around the earth electrode with concrete earth pit in PCC (1 : 3 : 6) type C-1, cast iron frame, 50mm thick pre cast RCC 1:1.5:3 type A-1 cover slab of size 450x450x50 mm reinforced with 8mm dia TMT bar 10cm c/c and suitable handle of 10mm dia round bar, including necessary excavation, earth work in soft/loose soil and Sand disposal of spoil to a distance n.exc 50m and necessary testing complete all as shown in Electrical Plate No 3 of SSR Part I. (Note : Earthing strip & GI protection pipe beyond 7.5 mt shall be measured & paid separately)
S&F Integral sleek extruded polycarbonate baton integrated LED channel 18 Watt neutral white with white acrylic cover complete all as directed. Make :- Bajaj cat No BCLSB 18 NW or equivalent from make list as specified in PS.
S&F LED Recess mounting luminaries 43 Watt Neutral White including necessary connection complete all as directed. Make :- Bajaj cat No BCTBLR 43W ZTN WH or equivalent from make list as specified in PS.
S&F Baton Integral sleek extruded polycarbonate 5 Watt Neutral White LED channel with white acrylic cover complete all as directed. Make :-B46
Supply and laying 90mm outer dia 3 layer PP-R (Polypropylene random co-polymer) pipes, (SDR11/PN-10) conforming to IS 15801, outer green colour UV stabilized, inner white colour antimicrobial & middle black plain PP-R layer, ISI marked, fusion welded, having thermal stability for hot & cold water supply including all PP-R plain fittings and brass threaded fittings PN-25, laid in trenches/fixed to wall etc complete all as specified and directed. (Note :- Clamping for PP-R pipe on wall, the distance between two clamps not more than 0.5 mtr and clamp must be supplied by the PPR manufacturer only.)
Supply and laying 63mm outer dia 3 layer PP-R (Polypropylene random co-polymer) pipes, (SDR11/PN-10) conforming to IS 15801, outer green colour UV stabilized, inner white colour antimicrobial & middle black plain PP-R layer, ISI marked, fusion welded, having thermal stability for hot & cold water supply including all PP-R plain fittings and brass threaded fittings PN-25, laid in trenches/fixed to wall etc complete all as specified and directed. (Note :- Clamping for PP-R pipe on wall, the distance between two clamps not more than 0.5 mtr and clamp must be supplied by the PPR manufacturer only.)
Supply and laying 50mm outer dia 3 layer PP-R (Polypropylene random co-polymer) pipes, (SDR11/PN-10) conforming to IS 15801, outer green colour UV stabilized, inner white colour antimicrobial & middle black plain PP-R layer, ISI marked, fusion welded, having thermal stability for hot & cold water supply including all PP-R plain fittings and brass threaded fittings PN-25, laid in trenches/fixed to wall etc complete all as specified and directed. (Note :- Clamping for PP-R pipe on wall, the distance between two clamps not more than 0.5 mtr and clamp must be supplied by the PPR manufacturer only.)
Sub main wiring with 2 runs (P-N) of single core 10 sqmm stranded PVC insulated unsheathed copper conductor cable 1100 volts rate drawn through adequate size PVC non-metallic concealed conduit incl 1x10 sqmm PVC insulated unsheathed stranded copper conductor green in colour for earth continuity conductor and connected to common earth dolly complete all as specified and as directed. (Note: Two runs of 10 sqmm cable and one run of 10 sqmm earth continuity conductor shall be measures as one run length)
Sch 'A' Part-XV PILE FOUNDATION BLANK
Sch 'A' Part-XVI SCHEDULE OF CREDIT Note :- Amount of Rs. 1,92,700.00 indicated in Tender Documents as Schedule of Credit shall be deducted from the total quoted amount of BOQ.
M/s AGAM CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .