Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 LAccepted-Finance 92 OLD AGRAWAL NAGAR INDORE | INDORE | INDORE | MADHYA PRADESH | L1 | Accepted-Finance L-1 for Only Barbed Wire | |
| 2 | L1₹18 LAccepted-Finance | L1 | Accepted-Finance L-1 for RCC Pole and PRCC Poles | |
| 3 | L2Accepted-Finance VILLAGE HARSOLA TEHSIL MHOW DISTRICT INDORE 453441 | INDORE | MADHYA PRADESH | 453441 | L2 | Accepted-Finance L-2 for PRCC Pole | |
| 4 | L2Accepted-Finance | L2 | Accepted-Finance L-2 for RCC Pole | |
| 5 | L3Accepted-Finance JANAKPUR ROAD PURUSHOTTAMPUR PANNA DISTRICT PANNA M P | PANNA | PANNA | MADHYA PRADESH | L3 | Accepted-Finance L-3 For Barbed Wire |
| Sl No | Description | Qty | Unit | VISHAL INDUSTRIES | SAI INDUSTRIES | SHRI GANESH INDUSTRIES | KESHAV INDUSTRIES | NAVKAR GRANITE | AMAN ENTERPRISES | KRISHNA INDUSTRIES |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00FENCING MATERIAL | ||||||||||
| 1.01 | RCC Fencing Poles Height 2.0 m
Type - Straight
Length - 2.00 m
Dimensions - Bottom 10x10 cm square, Top 8x8 cm square
Cement Concrete Mix- Cement, sand and metal ratio 1:2:4, with 12.5 nominal size coarse aggregate. Sand used should be free from clay and salt. concrete mix shall be conforming to grade M-15 of IS:456:2000
Reinforcement- 4 round vertical bars of 6 mm diameter, 11 no of stirrups of 6 mm diameter round MS bars 20 cm centre to centre.
Hooks- 5 no, bottom hook should be provided 60 cm above the bottom of the pole, second at 82.5 cm, third hook at 112.5 cm, fourth hook at 150 cm, top and fifth hook at 195 cm from bottom.
Manufacturing- In order to ensure desired compressive strength. RCC fencing poles should be compacted with the help of platform vibrators. Surface should be uniform and free from voids. The concrete cover over the reinforcement should not be less than 1.5 cm. | 1 | Nos | 288 ₹288 | 285 ₹285 | 263 ₹263 Lowest | 292 ₹292 | - | - | 291 ₹291 |
| 1.02 | Galvanised Steel Barbed Wire
Line Wire - Galvanised steel wire of 2.5 mm diameter (Tolerance ±0.08 mm as per IS-278-2009) Standard
Point wire - Galvanised steel wire of 2.5 mm diameter (Tolerance ±0.08 mm mm as per IS-278-2009) Standard
Barbs - Distance between two boards 75mm (Tolerance ±12mm as per IS-278-2009) Standard. The barbs shall have four points and shall be formed by twisting two point wires each two turns. tightly around both the line wires making altogether four complete turns.
Standard - Conforming to IS-278-2009 | 1 | KG | 72 ₹72 | 70 ₹70 | - | 68.44 ₹68.44 Lowest | 81 ₹81 | 70.21 ₹70.21 | - |
| 1.03 | PRE STRESSED RCC FENCING POLES
Type- Straight Length - 2.00 m
Dimensions - Bottom 10x10 cm square,
Cement Concrete Mix- Concrete Mix Shall be conforming to grade M-15 of IS:456:2000
Reinforcement - There Shall be 4 Nos. of vertical reinforcement of high tensile steel wire of 4 mm dia. Holes Hooks - 6 nos, bottom hole should be provided 50 cm above the bottom of the poles, The central distance between the top and bottom holes shall be equally divided for remaining holes. J Hook shall be of 6mm dia MS Bar with proper threads at one end nut and washer for tightening purpose. These J bolts shall be pass through the holes of poles.
Manufacturing- In order to ensure desired compressive strength, RCC fencing poles should be compacted with the help of platform vibrators. Surface should be uniform and free from voids. The concrete cover over the reinforcement should not be less than 1.5 cm.
Standard -. Conforming to IS 4996:1984 with up to date amendments | 1 | Nos | 215 ₹215 | 213 ₹213 | 205 ₹205 Lowest | 208 ₹208 | 225 ₹225 | - | 207 ₹207 |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
29 Sept 2025, 12:30 pmClosed
Divisional Forest Officer Shajapur
DFO Office A.B. Road, Lalghati Near Telephone Tower, Shajapur M.P.
RCC Poles Barbed Wire PRCC Poles
2025_MPFD_449871_1
DFO_SJR_2025_06
Open Tender
Miscellaneous Goods
Item Wise
All Shajapur Division District Shajapur and Agar
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,000
Yes
₹80,000
Yes
Shajapur
5 Nov 2025
9 Sept 2025
30 Sept 2025
9 Sept 2025
29 Sept 2025
9 Sept 2025
10 Sept 2025
FENCING MATERIAL
RCC Fencing Poles Height 2.0 m Type - Straight Length - 2.00 m Dimensions - Bottom 10x10 cm square, Top 8x8 cm square Cement Concrete Mix- Cement, sand and metal ratio 1:2:4, with 12.5 nominal size coarse aggregate. Sand used should be free from clay and salt. concrete mix shall be conforming to grade M-15 of IS:456:2000 Reinforcement- 4 round vertical bars of 6 mm diameter, 11 no of stirrups of 6 mm diameter round MS bars 20 cm centre to centre. Hooks- 5 no, bottom hook should be provided 60 cm above the bottom of the pole, second at 82.5 cm, third hook at 112.5 cm, fourth hook at 150 cm, top and fifth hook at 195 cm from bottom. Manufacturing- In order to ensure desired compressive strength. RCC fencing poles should be compacted with the help of platform vibrators. Surface should be uniform and free from voids. The concrete cover over the reinforcement should not be less than 1.5 cm.
Galvanised Steel Barbed Wire Line Wire - Galvanised steel wire of 2.5 mm diameter (Tolerance ±0.08 mm as per IS-278-2009) Standard Point wire - Galvanised steel wire of 2.5 mm diameter (Tolerance ±0.08 mm mm as per IS-278-2009) Standard Barbs - Distance between two boards 75mm (Tolerance ±12mm as per IS-278-2009) Standard. The barbs shall have four points and shall be formed by twisting two point wires each two turns. tightly around both the line wires making altogether four complete turns. Standard - Conforming to IS-278-2009
PRE STRESSED RCC FENCING POLES Type- Straight Length - 2.00 m Dimensions - Bottom 10x10 cm square, Cement Concrete Mix- Concrete Mix Shall be conforming to grade M-15 of IS:456:2000 Reinforcement - There Shall be 4 Nos. of vertical reinforcement of high tensile steel wire of 4 mm dia. Holes Hooks - 6 nos, bottom hole should be provided 50 cm above the bottom of the poles, The central distance between the top and bottom holes shall be equally divided for remaining holes. J Hook shall be of 6mm dia MS Bar with proper threads at one end nut and washer for tightening purpose. These J bolts shall be pass through the holes of poles. Manufacturing- In order to ensure desired compressive strength, RCC fencing poles should be compacted with the help of platform vibrators. Surface should be uniform and free from voids. The concrete cover over the reinforcement should not be less than 1.5 cm. Standard -. Conforming to IS 4996:1984 with up to date amendments
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .