Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹9.5 L
EMD Value
₹9,500
Closing Date
1 Dec 2026, 12:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Executive Officer
Near Block Office Pacode Town Panchayat
Improvements at Elamthiruthi Panchayat Auditorium in Pacode Town Panchayat
2026_DTP_725826_1
29/2025/A1
Open Tender
Civil Works
Works
90 days
Pacode
-
2 documents required · 2 mandatory
₹0
₹9,500
12 Nov 2026
12 Nov 2026
1 Dec 2026
12 Nov 2026
1 Dec 2026
12 Nov 2026
12 Nov 2026 - 1 Dec 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Cement concrete 1:2:4 (one part of cement two part of sand and four part of aggregates) using machine broken granite jelly of 20 mm size for all cement concrete works excluding cost of centering shuttering strutting and also cost of reinforcement grill in position but including laying vibrating with mechanical vibrators using finishing etc complete, as directed by the departmental officers etc complete complying with standard specification. | 2 | m3 | - | - |
| 2 | Supplying and fixing Solid Blocks of following size conflirming to SS 2145-1965 (including jam blocks closers etc) made in cement concrete 1:3:6 mix in cement mortor 1:5 and partition wall including curing neat finishing etc complete complying with standard specification and as directed by the departmental officers etc (Approved by SE(CW) in Lr.No, 15056/95/DB/S1/Dated 23.08.95) | 1.5 | m3 | - | - |
| 3 | Supplying and erecting centering to sides and soffits including supports and strutting with necessary centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86. | 4 | m2 | - | - |
| 4 | Supplying, fabricating and placing in position of Steel Reinforcement using Mild steel or ribbed tar steel rods, for all RCC works as per the design given by the departmental officers including cost of steel cutting, bending, placing in position and binding with binding wire and all labour charges for cutting, bending, tying and placing in position etc, complete. TNDSS No:97 | 75 | kg | - | - |
| 5 | Reinforcement Cement concrete 1:1½:3 (one part of cement one and a half part of sand and three part of aggregates) using machine broken granite jelly of 20 mm size for all reinforced cement concrete works excluding cost of centering shuttering strutting and also cost of reinforcement grill in position but including laying vibrating with mechanical vibrators using finishing etc complete, as directed by the departmental officers etc complete complying with standard specification. TNDSS No:30 | 1 | m3 | - | - |
| 6 | Painting two coats with ready mixed plastic emulsion paints of first class quality and of approved colour over old existing coat including through scraping clean removal of dirt etc, complete and including cost of necessary plaster of paris, putty, brushes, wherever required and all labour charges, scaffolding charges etc., complete as per standard specification. | 1,723 | m2 | - | - |
| 7 | Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (U PVC) sections. The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside.1 Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. | 5.1 | m2 | - | - |
| 8 | Supplying and fixing of steel windows with suitable design including cost of materials, welding and conveyance of all materials to site locking arrangements and painting one coat of primer etc complete as per standard specification including fixing charges etc. complete for the work. | 3 | m2 | - | - |
| 9 | Supply and fixing of 4 Feet LED 18W Fitting with LED 20W tube (Higher End) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting SD 443 | 20 | No | - | - |
| 10 | Supply and fixing of 1200mm (48") AC ceiling fan complete with stepped electronic 300W regulator with 300mm down rod on the existing clamp SD 110 | 11 | No | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.78 MB
BOQ_871301.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .