Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance XIV 718 CLINT ROAD VADAVUCODE PUTHENCRUZ AMBALAMEDU PO AMBALAMEDU ERNAKULAM KERALA 682303 | ERNAKULAM | KERALA | 682303 | Admitted-Finance |
| 2 | Rejected-Technical | Rejected-Technical No proper Solvency certificate |
Tender Value
Refer Docs
EMD Value
₹25,000
Closing Date
26 Oct 2019, 12:00 pmClosed
DGM (P and C)
FEDO, Udyogmandal PO, Eloor, Kalamssery, Kochi 683501
As per tender document
2019_FACT_501242_8
08001/2019-2020/E20197
Open Tender
Miscellaneous Works
Item Rate
120 days
Vellore, Tamil Nadu
As per tender document
3 documents required · 3 mandatory
₹5,000
Yes
FEDO FACT
₹25,000
Yes
7 Feb 2020
12 Oct 2019
29 Oct 2019
12 Oct 2019
26 Oct 2019
12 Oct 2019
12 Oct 2019 - 26 Oct 2019
Felling trees of the girth (measured at a height of 1m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. Beyond 30 cm girth up to and including 60cm girth
Clearing thick and thorny jungle including uprooting of rank vegetation, grass, brush wood trees and saplings of trees up to 30cm girth measured at a height of 1m above G.L and removal of rubbish up to a distance of 150m outside the periphery of the area cleared.
Dismantling carefully existing damaged AC/ translucent sheet roofing wherever required and stacking the serviceable materials at places pointed out within a lead of 150m
Dismantling carefully existing damaged ridges and stacking the serviceable materials at places pointed out within a lead of 150m.
Realignment of dislodged ridges, with necessary fittings etc. complete
Providing non-asbestos colour coated high impact resistant polypropylene reinforced cement 6mm thick corrugated sheets (As per IS: 14871) roofing up to any pitch and fixing with self-drilling fastener and EPDM washers, etc. complete. excluding the cost of purlins, rafters, and trusses and including cutting to size and shape wherever required
Dismantling valleys/ rain water gutter including all accessories, and stacking the material within 50 meters lead as per the directions of the engineer in-charge.
Providing and fixing on wall face un-plasticised 110mm Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion, (I) single socketed pipes
Dismantling and removing carefully the existing RRM wall in cement mortar at all levels and conveying and depositing the debris and stacking the serviceable at places pointed out within a distance of 150m
Chipping and removing carefully to the required area the existing cement plaster of wall, floor, ceiling etc. and cleaning the surface and removing the debris to places pointed out within a distance of 150m
Dismantling carefully and removing the existing CC/RCC works and conveying and depositing the debris at places pointed out within a distance of 150m. - chambers and manholes
Renewing Float glass panes of thickness 4 mm and re-fixing existing wooden fillets:
Dismantling tile work in floors / walls laid in cement mortar including stacking material within 50 metres lead. In toilets
Replace and fixing new seat with lid for European closets (colour to suit existing EWC)
Replace and fixing new PVC Spout (110 OD or nearest) including chipping of concrete to make the opening suitable for new spout size, cement grouting the joints with added water proofing material.
Cement concrete work in 1:5:10 mix (1 cement: 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size). using first class 20mm nominal size hard granite broken stones including all charges for mixing concrete, laying, consolidating, curing, etc. complete - for walk way
Cement concrete work in 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) using first class 20mm nominal size hard granite broken stones including all charges for mixing concrete, laying, consolidating, curing, etc. complete for - Drain, walk way and plinth protection
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. for works up to plinth level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Providing and laying Pre cast Reinforced cement concrete cover slab of 1:1.5:3 nominal mix concrete using 20 mm and down grade hard granite broken stones including all charges for cost of form work, machine mixing concrete, laying, mechanically vibrating, consolidating, finishing to a fair face, curing, etc. complete but excluding reinforcement for drains Pre cast cover slabs / beams
Supplying and providing reinforcement to R.C.C works at all levels with high strength deformed bars Grade Fe 500D conforming to IS 1786, including all charges for uncoiling and straightening rods, cutting rods, bending cold, placing in position and tying with black annealed steel wire of 16 SWG, etc. complete.
Providing form work to cement concrete and RCC works with necessary plywood/steel sheet, steel joists, runners, struts, posts etc with adjustable spans and telescopic posts, wooden planks etc. including removal after completion /curing at all level for Foundations, footings, bases of columns, etc. for mass concrete
Providing form work to cement concrete and RCC works with necessary plywood/steel sheet, steel joists, runners, struts, posts etc with adjustable spans and telescopic posts, wooden planks etc. including removal after completion /curing at all level for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Providing form work to cement concrete and RCC works with necessary plywood/steel sheet, steel joists, runners, struts, posts etc with adjustable spans and telescopic posts, wooden planks etc. including removal after completion /curing at all level for Columns, Pillars, Piers, Abutments, Posts and Struts
Providing and laying dismantled random rubble masonry available at site in cement mortar 1:6 for foundation and basement, etc, with hard granite stones.
Applying one coat of cement primer of approved brand and manufacture on wall surface
Finishing walls with Acrylic Smooth exterior paint of required shade. Two or more coat applied @ 1.67 ltr/10 sqm over priming coat of cement prime applied @ 2.20 kg/10 sqm)
Applying priming coat with ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting the existing rolling shutter, with one coat of zinc chromate primer and two coats of synthetic enamel paint of approved quality and colour over the primer after Greasing rolling shutters, and scraping, cleaning old painted surfaces with sand paper etc complete
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In ladder, railings, gates and similar works
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Applying priming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat) structural steel
Painting two or more coats with synthetic enamel paint of approved brand and manufacture to give an even shade for wood and structural steel
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours & shades, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. Toilet Floor
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades & any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. Toilet Wall
Supplying and fixing P.V.C. pipes conforming to IS 4985 class II-4kg/sq.cm pressure for rain water lines with all required specials such as plain bends, single junctions, elbows, crosses, unions, shoes, door bends, double junctions, vent cowls, etc. with or without door including cutting masonry or concrete floors, sunshades, etc. wherever necessary and jointing pipes with approved quality resin cement and fixing clamps screwed on to wooden plugs embedded in masonry wherever required and painting the clamps with two coats of enamel paint over one coat primer, etc. complete - 110 mm or nearest outer dia sewage waste line to septic tank
Supplying, laying, jointing & hydrostatically testing ISI marked PVC pipes conforming to IS 4985 and all required PVC specials such as tees, bends, elbows, unions, reducers, adapters, coupling etc., as per IS 7834 or IS 10124 as the case may be, including cost of all jointing materials like solvent cement, bolts, nuts, rubber washers, ferrule, pipe supports, etc., hire of tools and plant, cost and conveyance of water for testing etc. complete so as to withstand the internal design pressure of 6 kg/cm2 for 32mm OD Rerouting - water supply line to water tank from motor
Cutting and removing the existing entrance gate with hinges and all fittings and re-fixing the same on new pedestals as per the directions of engineer in-charge all works, including, cutting, welding, levelling and aligning the gates
Chipping and removing carefully the existing damaged RCC works to required sizes and depth ,Cleaning the corroded steel reinforcement with mechanical brush ,scrubbing ,wire brushing and finally cleaning the surfaces with a jet of air so as the surface shall have a pronounced metallic sheen and painting one coat of anti-corrosive coating using two component, epoxy zinc rich primer to meet the requirement of BS 4652 Type 2, like CONCRESIVE ZRi manufactured by BASF or equivalent make on the exposed surfaces of existing reinforcement , providing and laying Reinforced cement concrete of 1:1.5:3 nominal mix using 20 mm and cement grout on old RCC surface, including supply of all materials, necessary formworks ,cleaning the surface, conveyance, labour, etc
Providing and fixing 15 cm wide, 45 cm overall semi-circular PVC half round gutter with all fittings, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m²
Dismantling wooden door shutter with grill including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead
Greasing grill after cleaning old surfaces with sand paper etc., cleaning the channels in floor and top complete and applying a coat of primer and two coats of synthetic enamel paint of approved colour and make.
Supplying unskilled labour for cleaning, shifting items etc on per day basis (8 hours a day)
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. For gate pillar
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. for Drains
Providing and laying 80mm GI pipe in the ground after trenching to a depth of 30cm, inserting PVC pipe through the GI pipe including jointing of pipes & fittings & testing of joints complete as per direction of Engineer in Charge excluding the cost of inserted PVC pipe
Providing and fixing ridges and hips in non- asbestos colour coated high impact polypropylene reinforced cement 6 mm thick corrugated sheets roofing with suitable fixing accessories or self-drilling fastener and EPDM washer etc. complete.
1:3 (1 cement: 3 fine sand) 6 mm cement plaster
Neat cement punning in drains
Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement: 6 coarse sand)
Supply and Wiring for light point /exhaust fan with 1.5Sq.mm FRLSH PVC insulated stranded single core copper conductor cable through 20mm dia 1.5mm thick Electrical grade PVC conduit with ISI mark clamped in wall, ceiling or column including supply and fixing of 3Plate ceiling rose in 3x3 uPVC Box with UPVC cover surface in wall, 1No 6A ordinary switch with ISI mark fixed in hylum sheet in suitable surface mounting box and earthing with 1.5Sq.mm insulated copper conductor etc. including supply of all fixing materials and accessories and interconnections complete as required. The scope of erection shall also include dismantling of existing points if any. - supply
Supply and Wiring for light point /exhaust fan with 1.5Sq.mm FRLSH PVC insulated stranded single core copper conductor cable through 20mm dia 1.5mm thick Electrical grade PVC conduit with ISI mark clamped in wall, ceiling or column including supply and fixing of 3Plate ceiling rose in 3x3 uPVC Box with UPVC cover surface in wall, 1No 6A ordinary switch with ISI mark fixed in hylum sheet in suitable surface mounting box and earthing with 1.5Sq.mm insulated copper conductor etc. including supply of all fixing materials and accessories and interconnections complete as required. The scope of erection shall also include dismantling of existing points if any. - erection
Supply and wiring light points as in items 51 & 52 above in such a way that light can be controlled from two points independently by using 2-way switch - Supply
Supply and wiring light points as in items 51 & 52 above in such a way that light can be controlled from two points independently by using 2-way switch - Erection
Supply and Wiring for group controlled light points (from one light point to another light point), same as items 51 & 52 but without control switch. Wiring from control switch to first light point is covered in item No.51 & 52. The scope of erection shall also include dismantling of existing points, if any. - Supply
Supply and Wiring for group controlled light points (from one light point to another light point), same as items 51 & 52 but without control switch. Wiring from control switch to first light point is covered in item No.51 & 52. The scope of erection shall also include dismantling of existing points, if any. - Erection
Supply and Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLSH PVC insulated stranded single core copper conductor cable ,through 20mm/32mm dia 1.5mm thick Electrical grade PVC conduit with ISI mark surface in wall, ceiling or column or floor including supply of all fixing materials and interconnections complete as required for circuit wiring from the distribution board to first switch board. The scope of erection shall also include dismantling of existing wiring if any - 2Runs 4Sq.mm FRLSH PVC+4Sq.mm FRLSH PVC copper conductor as earth wire for incoming wire to DB. - Supply
Supply and Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLSH PVC insulated stranded single core copper conductor cable ,through 20mm/32mm dia 1.5mm thick Electrical grade PVC conduit with ISI mark surface in wall, ceiling or column or floor including supply of all fixing materials and interconnections complete as required for circuit wiring from the distribution board to first switch board. The scope of erection shall also include dismantling of existing wiring if any - 2Runs 4Sq.mm FRLSH PVC+4Sq.mm FRLSH PVC copper conductor as earth wire for incoming wire to DB. - Erection
Supply and Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLSH PVC insulated stranded single core copper conductor cable ,through 20mm/32mm dia 1.5mm thick Electrical grade PVC conduit with ISI mark surface in wall, ceiling or column or floor including supply of all fixing materials and interconnections complete as required for circuit wiring from the distribution board to first switch board. The scope of erection shall also include dismantling of existing wiring if any - 2 runs 2.5 sq.mm FRLSH PVC+ 2.5Sq.mm FRLSH PVC Copper conductor as earth wire - Supply
Supply and Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLSH PVC insulated stranded single core copper conductor cable ,through 20mm/32mm dia 1.5mm thick Electrical grade PVC conduit with ISI mark surface in wall, ceiling or column or floor including supply of all fixing materials and interconnections complete as required for circuit wiring from the distribution board to first switch board. The scope of erection shall also include dismantling of existing wiring if any - 2 runs 2.5 sq.mm FRLSH PVC+ 2.5Sq.mm FRLSH PVC Copper conductor as earth wire - Erection
Supply and fixing of 3 pin 5/6 amps socket outlet and 5/6 amps switch having ISI marks, fixed in hylum sheet and in box suitable for surface mounting in wall with all fixing materials and interconnections as required. The scope of erection shall also include dismantling of existing points if any -Supply
Supply and fixing of 3 pin 5/6 amps socket outlet and 5/6 amps switch having ISI marks, fixed in hylum sheet and in box suitable for surface mounting in wall with all fixing materials and interconnections as required. The scope of erection shall also include dismantling of existing points if any - Erection
20W LED batten suitable for surface mounting prewired up to terminal block with all accessories such as drivers, lamp holders, lamp etc. with acrylic diffuser and with decorative end caps and all related accessories like rods for suspension, wires etc. (WIPRO GARNET DM532065 or equivalent type of Crompton Greaves/ Philips /GE Lighting Ltd / WIPRO/ Havells) - Supply
20W LED batten suitable for surface mounting prewired up to terminal block with all accessories such as drivers, lamp holders, lamp etc. with acrylic diffuser and with decorative end caps and all related accessories like rods for suspension, wires etc. (WIPRO GARNET DM532065 or equivalent type of Crompton Greaves/ Philips /GE Lighting Ltd / WIPRO/ Havells) - Erection
10W LED batten suitable for surface mounting prewired up to terminal block with all accessories such as drivers lamp holders, lamp etc. with acrylic diffuser and with decorative end caps and all related accessories like rods for suspension, wires etc. (WIPRO GARNET DM531065 or equivalent type of Crompton Greaves/ Philips /GE Lighting Ltd / WIPRO/ Havells) - Supply
10W LED batten suitable for surface mounting prewired up to terminal block with all accessories such as drivers lamp holders, lamp etc. with acrylic diffuser and with decorative end caps and all related accessories like rods for suspension, wires etc. (WIPRO GARNET DM531065 or equivalent type of Crompton Greaves/ Philips /GE Lighting Ltd / WIPRO/ Havells) - Erection
Dismantling and cleaning of existing light/ ceiling fan and keeping it in safe custody and re-installation of light/ ceiling fan after completion of the maintenance work in the godown. Scope of work shall also include suitable maintenance required for making light/ ceiling fan function smoothly.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .