Loading…
Loading…
Tender Value
₹48.0 L
EMD Value
₹96,100
Closing Date
4 Sept 2026, 6:00 pm
HQ CWE PRAYAGRAJ
HQ CWE NEW CANTT PRAYAGRAJ
SPL REPAIR/REPLACEMENT TO BER WATER COLLER, DESERT COOLER AND DEEP FREEZER OF VARIOUS CAPACITY ALONGWITH CERTAIN ALLIED WKS, CEILING FANS WITH BLDG FANS AND BER GEYSERS 25/50 LTRS AND PROVN OF WALK IN COOLER AT MED STORE OF MH AYODHYA UNDER AGE (i)
2026_MES_784543_1
82077/AYD/E8
Open Tender
Civil Works
Item Rate
180 days
Ayodhya
Class D and Category b(i)
6 documents required · 6 mandatory
₹500
AGE (I) Ayodhya
₹96,100
Yes
14 Aug 2026
14 Aug 2026
11 Sept 2026
14 Aug 2026
4 Sept 2026
28 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | S&F desert cooler electric driven (single phase), having nominal air flow capacity of 95L with ice chamber alongwith 3 side honeycomb pads with bacteria shield technology including provision of PVC stand for mounting of desert cooler complete all as specified and as directed.
Make:- Havells, Model-KoolStorm 95 L Desert Air Cooler, 95 L, White/Grey Cat No-GHRACCLE095 or equivalent cat part of make Crompton/Usha.
Note:- Rate included for taking down old existing desert cooler declared BER of any type and capacity from site and deposit to MES store carefully without any damage. | 34 | Each | 1.25 | ₹42.5 |
| 2 | S&F water cooler electric driven single phase having approximate storage capacity 80 Ltr and nominal cooling capacity 40 Ltrs per hour complete including PCC platform of suitable size complete all as specified and as directed.
Make:- Voltas, Model No-6010518 / WC FS 40/80 N P R134a or equivalent cat part of Blue star/Carrier.
Note:- Rate included for taking down old existing water cooler declared BER of any type and capacity from site and deposit to MES store carefully without any damage. | 24 | Each | 2.25 | ₹54 |
| 3 | Supply, installation and commissioning of metal top deep freezer of capacity 210 Ltrs single phase 240 volt, 50 Hz complete all as specified and as directed.
Make:- Bluestar, Model No- NEWY R600a or equivalent cat part of Voltas/Carrier.
Note:- Rate included for taking down old existing deep freezer declared BER of any type and capacity from site and deposit to MES store carefully without any damage. | 3 | Each | 3.25 | ₹9.75 |
| 4 | S&F voltage stabilizer (copper wound) for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and as directed.
Note:- Rate included for taking down old existing voltage stabiliser of any type and capacity from site and deposit to MES store carefully without any damage. | 3 | Each | 4.25 | ₹12.75 |
| 5 | S&F voltage stabilizer (copper wound) for automatic operation, Single phase air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of + 2.5% and capacity 2 KVA complete all as specified and as directed.
Note:- Rate included for taking down old existing voltage stabiliser of any type and capacity from site and deposit to MES store carefully without any damage. | 24 | Each | 5.25 | ₹126 |
| 6 | M&L for concealed power point wiring with single core, multi stranded copper conductor, PVC insulated unsheathed 4.0 sq mm FRLSH cable drawn into concealed rigid PVC conduit of size not less than 25 mm dia for one switch socket outlet 15 Amps on independent board with 4.0 sq mm for neutral and 2.5 Sq mm for earth wire including color coding with Red, Yellow, Blue for Phase, Black for Neutral and Green for Earth wire complete all as specified and as directed. | 5 | Per Point | 6.25 | ₹31.25 |
| 7 | M&L in repair for point wiring concelaed with 1.5 Sqmm (nominal area) PVC insulated un - sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through rigid non metallic conduit not less than 20mm size, medium grade with all necessary fittings, concealed wiring , for one 5/6A socket point controlled by one switch including 1.5 Sq mm PVC insulated unsheathed copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes/ on PVC rectangular block with 3 mm thick plastic laminated sheet cover of suitable size for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover ,for housing switches, socket outlet, regulator etc. and colour coding of copper conductor ie for Phase-Red/Yellow/Blue, Neutral-Black and Earthing-Green colour complete all as specified and directed. | 213 | Per Point | 7.25 | ₹1,544.25 |
| 8 | S&F in repair/replacment switch socket combination 2 – in – one, 3 Pin / 5 Pin, 5/6 amps flush type complete all as specified and as directed. | 10 | Each | 8.25 | ₹82.5 |
| 9 | S&F in repair/replacement switch socket combination 2 – in – one 6 Pin , 6 / 16 amps flush type universal all as specified and as directed. | 3 | Each | 9.25 | ₹27.75 |
| 10 | S&F in repair/replacement rotational moulded polyethylene water storage tanks 500 Ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed. | 5 | Each | 10.25 | ₹51.25 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.49 MB
Indexpageandfwdingpage.pdf
Tender Documents • 0.58 MB
BOQ_879099.xls
BOQ • 2.35 MB
Specialcondition.pdf
Additional Documents • 0.45 MB
Particularspecification.pdf
Additional Documents • 0.59 MB
Makes.pdf
Additional Documents • 0.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].