Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.6 LAccepted-AOC 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹12.6 L+₹1.7 L (15.1%)Rejected-Finance | L2 | Rejected-Finance Being higher bidder | |
| 3 | L3₹13.1 L+₹2.1 L (19.4%)Rejected-Finance | L3 | Rejected-Finance Being higher bidder |
Tender Value
Refer Docs
Closing Date
8 May 2021, 6:00 pmClosed
CWE AF AGRA
HQ CWE AF AGRA
REPAIR AND MAINT OF LIFTS AND GANTRY UNDER GE(AF) TECH AREA AGRA
2021_MES_430248_2
80020-29/E8
Open Tender
Civil Works - Lift Irrigation Schemes
Item Rate
180 days
GE AF TA AGRA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE AF TA AGRA
Exempted
2 Jun 2021
17 Apr 2021
10 May 2021
17 Apr 2021
8 May 2021
24 Apr 2021
Amount
Comprehensive maintenance of lift (03 Nos) upto 10 passenger of Johnson make electrically operated upto G+5 floors with fully automatic door with V3F driven system at SRE 25 ISU and ATC building etc complete all as specified and directed. Make Johnson Note :- (i)The entire work mentioned above is inclusive of comprehensive, preventive and periodical maintenance of lifts/ elevators which shall be got executed through OEM or any reputed lifts manufacturer such as M/S Johnson Lifts Pvt. Ltd. etc only. The contractor shall submit the hard copy of MOU for AMC (inclusive of material) with lifts manufacuturer to the deptt before commencement of work (ii) Contractor shall deptoy trained trademen directely employed and supervised by OEM or reputed firm. The trademen shall be quailifed to keep equipment properly and take care to maintain the elevators equipment in proper and safe operating condition. (iii) Contractor shall regularly and systematically examine, adjust, lubricate as required all elevator parts such as gear, motor, controller, V3F drive, lift cabin. (iv) Contractor shall attend the break downs immeadiately on receipt of complaints (v) In case of emergency, contracor shall attend to the break down within an hours, failing which a panel recovery of Rs 500/- any will be made from contractor,s dues (vi) Contractor shall periodically equalize the tension on the hoistion to maintain an adequate factor of safety. (vii) Contractor shall examine periodically all safety devices and make monthly, quarterly, half yearly and yearly safety tests as per company norms.
M&L for repair of Lift of S.G. Series (At Rader cum Antenna building, lift No L-D2518) including renewal the following damage/unworkable parts and making the lift ready for smooth functioning:- (a) Door lock female contacts schersal- POD. 10 Nos. (b) Door lock male contacts schersal- POD. 10 Nos. (c) Door slippe, made of rubber as per existing. 20 Nos. (d) Door spring (C.O) for 800 mm opening and fixed on exigsting workable strip 05 Nos. (e) Nylon roller 'V' Assembly as per existing size and shape - 20 Nos. (f) Car shoe liner with 10 mm space. 04 Nos. (g) CWT Shoe liner (Button type). 12 Nos. (h) Charger unit 01 No (j) Charger battery (12V -2.5AH). 01 Nos (k) Automatic rescue device battery (12V -18AH). 04 Nos. (l) Emergency lamp board - LED 12 volt, 02 Nos
M&L for repair of lift at ATC building (lift No L-H6092) including replacement the following damage/unworkable parts and making the lift ready for smooth functioning:- (a) Automatic rescue device battery (12V -18AH) - 04 Nos. (b) Charger battery (12V -2.5AH). 01.00Nos (c) Door lock female contacts schersal- POD - 06 Nos (d) Door lock male contacts schersal- POD - 06 Nos
M&L for repair of Lift No L-E3171 including renewal the following damage/ unworkable parts and making the lift ready for smooth fuctioning:- (a) Floor announciator interface board of SG229/SG98- 12Volt. - 1. No. (b) Emergency lamp board - LED 12 volt, - 3 Nos (c) Charger unit 01.00 No. (d) Charger battery (12V -2.5AH) -1 Nos. (e) Door slipper, as per existing- POD - 8 Nos. (f) Car shoe liner with 10 mm space.- 4 Nos. (g) M type switch Nos - 2 Nos
Supply only, in replacement of Door Drive VVVF, including taking down of old / Unsearviceable items, complete all as directed.
Supply only, in replacement of infrared door sensor suitable for lift, complete all as directed.
Taking down old unserviceable battery from ARD and supply & fixing testing and comissioning dry maintenance free battery of capacity 12 volts 17 AH complete all as specified and directed by Engr-in-charge. Make Exide/Amron.
Taking down unserviceable LOP and supply, fixing and testing LOP complete assy for conunting of each floors up and down indication mark including wiring work upto control panel complete and masonary work if required at the time of taking down wall and proper finishing on top of the door entrance display complete all as specified and directed by Engr-in-Charge.
Supply only, in replacement, of Fuji VVVF-FRN 7.5 LMIS-4AA complete all as specified directed.
Supply only, in replacement, of Fuji VVVF-FRN 5.5 LMIS-4AA complete all as specified directed.
Supply only, in replacement of Logic Board for Johnson make ARD 25PIN- 1.5KVA and 2.5 KVA complete all as specified directed.
Supply only, in replacement of Mother Board for Johnson Make Lift UPS V7 complete all as specified directed.
M&L for servicing of EOT cranes of 2 ton capacity thoroughly including oiling, greasing and replacment of unserviceable parts/items after taking down complete including load testing for satisfactorly working of cranes all as specified and directed by Engr-in-Charge . Note: Parts/items shall be measured and paid seperately
Supply only in replacement Limit switch of suitable size for 2 ton capacity crane as per sample complete all as directed.
Supply only in replacement Contactor of 40 Amps 3 pole completed all as directed.
M&L for servicing of HOT cranes of 1 ton capacity thoroughly including oiling, greasing and replacment of unserviceable parts/items after taking down complete including load testing for satisfactorly working of cranes all as specified and directed by Engr-in-Charge . Note: Parts/items shall be measured and paid seperately
Supply Only in replacement Dog with spring as per sample completed all as directed.
Supply Only in replacement bearing 2310 & 2305 with pedastal in transmission shaft completed all as directed.
Supply Only in replacement Ratchet gear as per sample completed all as directed.
Supply Only in replacement Chain pulley block complete suitable for 1 ton capacity crane completed all as directed.
M&L for servicing of EOT cranes of 10 ton capacity thoroughly including oiling, greasing and replacment of unserviceable parts/items after taking down complete including load testing for satisfactorly working of cranes all as specified and directed by Engr-in-Charge . Note: Parts/items shall be measured and paid seperately
Supply Only in replacement Cable trolley as per sample completed all as directed.
Supply Only in replacement Operation switch as per sample completed all as directed.
Supply Only in replacement Emergency switch as per sample completed all as directed.
Supply only in replacement Contactor of 40 Amps 3 pole completed all as directed.
Supply Only in replacement Gear oil for gear box completed all as directed.
Supply Only in replacement Break fluid completed all as directed.
Checking of over head cranes any size,type , capacity and location for functioning of motors, unusual noise and nut bolt washers etc including testing for smooth functioning and inform Engr in Charge for repair if required complete all as directed by Engr-in-charge.
TRINITY CONSTRUCTION
MAX ELEVATOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .