| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.9 LAccepted-AOC | L1 | Accepted-AOC Being reasonable and Lowest L1 | |
| 2 | L2₹27.6 L+₹10,417 (0.38%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹27.7 L+₹22,038.50 (0.80%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
7 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col SS Bose CWE
HQ CWE (AF) Chakeri Kanpur 208008
SPECIAL REPAIR TO GYNAECOLOGY WARD AT 7 AFH KANPUR CANTT
2020_MES_367612_1
82135/E8
Open Tender
Civil Works
Item Rate
183 days
Chakeri Kanpur
Class D cat a (i)
8 documents required · 8 mandatory
₹500
GE (AF) B/R Chakeri
₹80,000
28 Oct 2020
8 Aug 2020
14 Sept 2020
8 Aug 2020
7 Sept 2020
24 Aug 2020
60 days
Amount
Complete removal of exisiting water proofing treatment of roof including , cleaning with wire brushes etc and removal of debris outside MD land complete all as specified and directed.
Demolition of cement concrete of any description and in any position including tiles complete all as specified and directed.
M&L PCC 1:2:4 type B-0 12.5 mm graded stone aggregate as in roof kerbs or mud stops, levelling coarses of roof, rounded or chamfered on edge average thickness not more than 75mm complete all as specified and directed.
Taking down cement plaster, any description on brick walls or on concrete Surfaces including raking out Joints, hacking for Key, scrubbing down with water, etc., and removing same from the site, complete all as specified and directed.
M&L 10 mm thick cement plaster in cement mortar 1:4 mixed with water proofing compound (to be measured and paid seperately as supply only) over PCC padding on roof including parapet and sunken floor complete all as specified and directed.
M&L providing and laying of fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymer having Sun reflective Index (SRI) of 105 manufactured by Asian Paints Ltd or equivalent as approved by GE on top of concrete roof with consumption @ 10.76 Ltrs/10 Sqm for three coats. One coat of self priming of elastomeric water proofing liquid (dilution with water in the ratio of 3 part of product and one part of water and two coat of undiluted elastomeric water proofing liquid (dry film thickness of complete treament not less than 500 microns). The operation shall be carried out after scrapping and properly cleaned loosed particles with wire brushes, filled the crack upto 3 mm with fibre glass reinforced crack filling compound 10, complete all as specified and directed by Engr-inchare.. Note :-(Roof treatment shall be done through authorised rep of applicator manufacturers only)
M&L providing and laying of two component cementitious elastomeric water proofing coating Damp Block 2K manufactured by M/s Asian paints Ltd or equivalent product of Berger, Shalimar in two coats consumption is not less than 1.4 kg/sqm to build 1.00 mm thickness as per manufacturers specification. The first coat shall be applied @ 0.7 kg/sqm and while 1st coat still green the second coat shall be applied with a suitable and stiff brush @ 0.7 kg/sqm. The treatment shall be carried out both horizontal and vertical surface as per site requirement and substantially curing to be done by ponding for 48 hours complete all as specified and directed.
M&L cement concrete 1:7:12 with 40mm graded stone coarse aggregate as in sunken floor of 150mm thick complete all as specified and directed.
M&L 32 mm dia galvanised tubing medium grade as in spout pipe each 50 cm long, cutting to shape as required, cutting through wall of any thickness, fixing in PCC 1:2:4 tpe B-1 and making good the damaged portion of concrete/plastered surfaces by rendering 15mm thick in CM (1:4) and finished the surface to match the existing surface complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and removing rubbish off the premises, complete all as specified and directed.
M&L Non–Skid Coloured ceramic jout free tiles, of 7-8 mm thick area of each tiles exc 0.06 sqm but n. exc 0.11 sqm, laid on floor, jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the Tiles,incl screed bed or bedding layer 20 mm thick in cement mortar 1:6 complete all as specified and directed.
M&L Joint free glazed ceramic digital coloured tiles of size 450X 350X 6-7mm thick or as required at site as in dado ,skirting set and jointed in neat cement slurry and pointed with coloured cement over and including10 mm thick rendering in CM (1:4) complete all as specified and directed.
S&F in repair 10 Ltr capacity PVC low level flushing cistern complete with siphon handle lever float valve and PVC bend incl connecting to it with India type WC or European type WC qand fixing on wall with new angle iron bracket complete all as specified and directed.
S&F in repairs vitrous china water closet (pedestal pan) snow white coloure complete with & including low level 10 ltr capacity PVC, valve less, syphonic action type flusing cistern (snow white) and white seat cover (PVC) with flat recessed bottom with chromium plated or aluminized hinges devices complete all as specified and directed. Note: coloured PVC cistern will be measured saperatly ).
S&F in repairs PVC waste pipe with coupling 32 mm diacomplete all as specified and directed. Make: prayag
S&F in repair 15mm bore bib tap cast copper alloy with crutch or butterfly handels screwed down for iron pipes or for brass ferrule complete all as specified and directed.
M&L of Cutting chases, pinning in, in brick wall making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring. etc. and making good, cutting not exceeding 10cm girth complete all as specified and directed.
S& F in repair Vitreous China Squatting Pan ‘ORISSA’ Pattern, size 580X440 mm White, with ‘P’ or ‘S’ Trap, Integral Foot Rest, providing Joints between Flush Pipe and Socket of WC Pan (excluding Flushing Cistern and Flush Pipe), fixing with and including provision of 150mm thick Lime Concrete Bedding including taking out unserviceable WC Pan and connected items, complete all as specified and directed.
S&F in repairs glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed.
S&F pillar taps 15mm bore, cast copper Alloy with Capstan Heads, Chromium Plated, screwed down high pressure with or without lettered ‘HOT’ or ‘COLD’ with long screwed shanks and fly-nuts, screwed for Iron pipe and fixed-in-repairs, complete all as specified and directed.
S&F of brass CP tubular towel rail 20 mm dia 60cm long between flange with brackets etc as in repaircomplete all as specified and directed.
S & F in repair Vitreous China wash basin, white, flat back size 580x450 mm including brackets, complete all as specified and directed.
S&F 75 mm bore cast iron pipes and vent pipes (sand cast), any length with or without ears with cement joint, fixed on walls fixed with 50x3 mm flat iron stay clamps including dismantling old CI pipes and removed from site,complete all as specified and directed.
S&F 100 mm bore cast iron pipes and vent pipes(sand cast), any length with or without ears with cement joint, fixed on walls fixed with 50x3 mm flat iron clamps including dismantling old CI pipes and removed from site complete all as specified and directed.
M & L CI floor trap with grattings incl joining to waste pipe fixed in cement concrete type B1 (1:2:4) suitable for 75 mm dia complete,
M&L 100 mm bore cast iron 'P' or 'S' trap fixed complete with M seal joint to cast iron 100 mm bore pipe duly fixed in position in repairs complete including closing the wall opening in cm 1:3 or as directed
S&F 100 mm bore cast iron sanitary connection socket fixed to WC outlet etc complete all as specified and directed.
S&F 100 mm bore dia cast iron bends (any radius) with duck's foot rest & oval access doors with cement joint, fixed on walls complete all as specified and directed.
S&F 75 mm bore dia cast iron bends (any radius) with duck's foot rest & oval access doors, with cement joint, fixed on walls complete all as specified and directed.
S&F PVC 110mm bore pipes in any length with tubber ring joints fixed to wall with dash through fastners and clamp of 25 x 3mm flat iron including all fittings like sockets, bend, junction, elbow etc complete all as specified and directed.
" All as per item No " 31 " above but bore of pipe 75 mm"complete all as specified and directed.
S&F 110mm PVC (SWR) bends complete all as specified and directed.
S&F 75 mm PVC (SWR) bends complete all as specified and directed.
Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, keep Serviceable Bricks in Safe Custody for re-use,complete all as specified and directed.
M&L for Brick Work with fly ash bricks, straight or curved on plan exc. 6.0 meter mean Radius, built in Cement Mortar 1:6, complete all as specified and directed.
M&L Rendering 15mm thick in Cement Mortar 1:4, finishing Plastered Surfaces Even and Smooth without using Extra Cement, complete all as specified and directed.
Taking down Chowkats or frames, exc. 1.50 sqm but not exc. 4.00 sqm each with Shutters (without taking Off shutters from the frames), complete all as specified and directed.
S&F PVC Solid Door Frame of Size 50X47mm made out of 5.0mm Plain Colour PVC Sheet Reinforced with Mild Steel Square tube as specified and as per manufacturer's instructions complete all as specified and directed.
S&F factory made solid panel PVC Door shutter 30mm thick (Style) consisting of Frame made out of mild steel tubes for top and bottom rails, mild steel frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC Sheet Strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and as gap insert for top rails & bottom rail, panelling of plain colour PVC sheet to be fitted in the mild steel frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement and fixing in the frame at site as per specifications and drawings, complete all as specified and directed.
S&F butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed type C21(100mm) complete all as specified and directed.
S&F aluminium anodised barrel tower bolts of extruded section, length of bolt in 150mm complete all as specified and directed.
S&F 250 mm long aluminums anodized sliding door bolts, ISI marked, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed complete all as specified and directed.
S&F extruded anodised aluminium alloy handles fabricated type 150mm complete all as specified and directed.
M&L chipping, removing carefully concrete work by low impact hammer, breaker without damaging the structure and cleaning and disposal of debris out side the premises etc complete all as specified and directed. (Note :Hard concrete should not be removed by force).
M&L cleaning existing reinforcement with wire/rotary wire brush, making the surface free from loose material dirt etc, complete applying two coats of alkaline rust converting primer (i.e. rust remover) FEOVERT conforming to ASTM-B-117, on the rebars (measurement shall be on the basis of exposed concrete) complete all as specified and directed. (Make : Feovert of Krishna Conchem, Roff rust cleaner of Pidilite, Dr Fixit Rust remover, ShaliRustOff of STP Ltd or equivalent as approved by GE)
M&L providing and applying two coats of anti-rust protective coating in the form of Acrylic Polymer mixed with Cement in 1:1.5 proportion (1 part polymer and 1.5 parts Cement) on rebars after cleaning of rust scales as per manufacturers instruction (measurement on the basis of exposed concrete area). complete all as specified and directed. (Make : IPNET of Krishna Conchem, or New Coat from Dr Fixit or equivalent as approved by GE)
M&L cement plaster 10 mm thick as in ceiling in CM 1:3 finished even and smooth in two coats of emulsion by using factory manufactured pre mix/ready mix of (make : Roofit Mix'of M/s Premier Floor to Roof Materials pvt.ltd or 'Easy plast' of M/s Walplast Products pvt.ltd or 'Readiplast' of M/s Ultratech Cement Ltd/'Soundplast PMC-1' of M/s Sound buildcare pvt.Ltd or other approved equivalent make by GE) mixed in cement mortar, including using richer mix for making corners if necessary, at all places and level, including making grooves of existing size wherever required, including cleaning the surfaces, curing etc. complete all as specified and directed.
M&L Sand faced cement plaster 20 mm thick in two coats using factory manufactured pre mix/ready mix of (Make : 'Roofit Mix'of M/s Premier Floor to Roof Materials pvt.ltd or 'Easy plast' of M/s Walplast Products pvt.ltd or 'Readiplast' of M/s Ultratech Cement Ltd/'Soundplast PMC-1' of M/s Sound buildcare pvt.Ltd or other approved equivalent make of mix by GE), having minimum composition of C:S :: 1:4 using fully treated dry, well graded natural sand conforming to IS 383 suitable for external plastering, having low rebound properties, low water demand for curing properties, mechnIcal mixing with water in a metalic tray only to make good consistency as per the specification of the Manufacturer and applied over exterior masonry and concrete surfaces with base coat of 12 mm thick and finishing coat of 8 mm thick final rendering,including using richer mix for making corners if necessary, at all floors and level, including making grooves of existing size wherever required, including cleaning the surfaces, curing etc. ccomplete all as specified and directed.
M&L preparing New Plastered Surfaces of Walls and applying Three Coats of White Wash, complete all as specified and directed.
M&L preparing Ceilings surface and applying Two Coats of White Wash, complete all as specified and directed.
M&L preparing New steel Surfaces of any description, over 10cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a Coat of Primer, complete all as specified and directed.
Taking down 15 mm bore GI tubing and including cleaning for refixing or removal to store complete all as specified and directed.
Taking down 20 mm bore GI tubing and including cleaning for refixing or removal to store complete all as specified and directed.
Taking down 25 mm bore GI tubing and including cleaning for refixing or removal to store complete all as specified and directed.
S&F Steel Water Tubing 15mm dia (Bore), Galvanised, ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situation with Fittings and Connections, etc., complete all as specified and directed.
S&F Steel Water Tubing 20 mm dia (Bore), Galvanised, ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situation with Fittings and Connections, etc., complete all as specified and directed.
S&F Steel Water Tubing 25 mm dia (Bore), Galvanised, ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situation with Fittings and Connections, etc., complete all as specified and directed.
Refixing 20 mm bore old steel tubing and connections in new or old position i(wall, ceiing floor etc) complete all as specified and directed.
Refixing 25 mm bore old steel tubing and connections in new or old position i(wall, ceiing floor etc) complete all as specified and directed.
Refixing 15 mm bore old steel tubing and connections in new or old position i(wall, ceiing floor etc) complete all as specified and directed.
Dismantaling water tanks and removing from site of capacity ext 500 Ltr n.exc 1000 Ltr complete all as specified and directed.
Disconnecting existing tanks setting aside, cleaning,etc and hoisting if required reconnecting and refixing in position complete all as specified and directed.
S&F 1000 Ltr Rotational moulded polyethylene water storage tanks three layered (cylindrical vertical with closed top) hosited and fixed in position complete all as specified and directed.
M&L complete removal of existing treatment on old decorated surface of wall applying two coat of acrylic emulsion (Ist quality) over a coat of alkali resistant primer over Birla/JK wall care putty 2mm thick complete all as specified and directed.
Complete removal of existing treated surface of walls and applying 2mm thick wall care Birla/JK putty and applying two coat of 100% antifungal acrylice emulision exterior grade wheather proof paint over a coat of alkli resistant primer complete all as specified and directed.
Supply only integral water proofing compound complete.
Cutting holes in RCC/Brick wall of superfacial area exc 250 sqcm but n exc 500 sqcm and 25 CM depth for fixing post/strut etc complete all as specified and directed.
Dismantling of false ceilling with cover fillet/frame works complete all as specified and directed.
M&L false ceiling made out of 600 x 600 x 4 to 6 mm thick laminated designer ceiling board /tiles deep panel suspensor system made out of powder coated GI sheet main Tee of size 23.50 x 40 x 0.63 mm and cross tee of size 23.50 x 23.50 x 0.63 mm and angle size 19 x 19 x 0.63 mm including 3 mm GI wire for suspending holts necessary washers nut/cleats/pin hook etc for securing frame work to ceiling to the snap grid including provn of necessary holes/cutting for providing light/far as required including making necessary recesses/projected pattern ccomplete all as specified and directed. (Make :- Armstrong or Chanakya or Everest or equivlalent a approved by GE)
Dismantling structural steel work including doors, gates, cattle traps etc, but excluding framed truss etc complete all as specified and directed.
M&L Mild Steel Framed Work as Grills, Grating, etc. with ends of Bar shouldered and/or riveted or forged into Spikes, Framed Guard Bars and Similar Work, etc. conforming to Fe-290 Gde E-165 including all necessary drilling, bolting or riveting, etc, complete all as specified and directed.
S&F 4 mm dia galvanised steel wire 100x100 mm mesh size, made up into mattress or cages, laped wired and laid in position including closing after filling complete all as specified and directed.
S&F framework such as grill gratings, etc with ends of bars shouldered and or riveted or welding, forged into spike; framed guard bar barred iron doors incl necessary hinges, pintle hinges, stops handle made sliding bolt etc confirmed to Fe_290 Gde E-165 complete all as specified and directed.
Dismantling of corrugated AC sheet in roof covering including rigdges & 'J' or 'L' hook complete all as specified and directed.
S&F for coloured galvalume profile sheet in roofing shall be with feed material manufactured from 0.50mm (minimum) base metal thickness (BMT), minimum 550 Mpa yield strength and shall confirm to physical specifications of ASTM-792 or equivalent, colour coated galvalume sheet shall have maximun pitch of 250 mm C/C and minimum 28 mm crest depth in length as per site requirment. The steel sheet shall be coated with hot dip metallic Aluminium Zinc alloy (55% Alluminium , 43.5% zink , 1.5% silicon) coatig AZ 150 as 150 gm/Sqm total on both sides. The contractor shall submit manufacturer test certificates for the chemical and mechnical properties, confirming genuinity of material including base metal thickness paint thickness and AZ 150 coating thickness must be submitted for approval to GE prior to the installation / fixing. The manufacturer of sheet should submit related documents for expected product services performances of pre painted metal sheet as per relevant ASTM/ IS. Manufacturer's recommended installatiosns methodology shall be adopted for installsiton of roofing including profiled sheet, capping , trims , flashings , gutter and all types of accessories considered for roofing , fastener shall be used for fixing roofing system as per manufacturer's recommendations. The painting shall be coloured backed enamal super durable polyester with silicon coating of film thickness of minimum 25 micron ( including primer) on top and minimum 10 micron ( including primer) on interior face. The paint shall be of shade as approved by GE and fixed with self drilling screws all as specifeid and directed. Note - Total thickness of sheet with BMT , AZ 150 coating and panting shall be minimum 0.575 mm thick. If 0.575 mm thickness sheet is not available then next higher thickness of sheet shall be applicable without any price adjustment.
S & F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L precast Re-inforced cement oncret type B-1, 1:2:4 (Using 20mm Graded Stone Aggregate),set in Cement Mortar 1:6 as in cover slab for manholes and drain, landing water troughs, shelves etc complete all as specified and directed.
M&L mild steel TMT bar 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends binding with and including mild steel wire not less then 0.9 mm dia or securing with clips quality conforming etc.complete all as specified and directed.
Demolition or breaking up 150 mm drain pipes (salt glazed ware AC or reinforced concrete ) set in cement mortar including breaking and removal of bedding and hunching complete all as specified and directed.
M&L for concrete bed to drain pipes for 150 mm internal dia RCC pipes in PCC (1:3:6) type C-2 using 40 mm graded stone aggregate including packing under and haunching against sides of pipes after they are laid and tested ccomplete all as specified and directed.
S&F reinforced concrete pipes, class NP3, laid and jointed complete with collars 150mm dia complete all as specified and directed.
Excavating in trenches n.exc 1.5 m wide and n.exc 1.5 m depth for fdn manholes sewer line etc(manualy) and getting out in soft/loose soil complete all as specified and directed.
Returning and filling in including spreading and leveling watering and well and ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated soil/demolished material exc 1.50 km and nexc 5km out side MD land depositing where directed complete all as specified and directed.
M&L cutting into existing manhole for connecting new suitable 150 to 200 mm dia pipes and making good to pipes and rendering cutting out existing benching for and forming branch channel(1/2 round & 3/4 section ) in cement concrete(1:2:4) type B-1 smooth finished and forming, benching as required complete all as specified and directed.
M&L PCC (1:4:8) type D2 using 40 mm graded stone aggregate as in foundation filling complete all as specified and directed.
M&L PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as surfaces channel and drains complete all as specified and directed.
SAXENA BANDHU
GOPI CONSTRUSTION CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .