Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹18.2 Cr B 26 AMBEDKAR COLONY CHATTARPUR NEW DELHI 110074 | ₹18.2 Cr |
Tender Value
₹24.5 Cr
EMD Value
₹24.5 L
Closing Date
7 Oct 2025, 11:00 amClosed
Construction of Permanent building of Composite Regional centre (CRC) including Civil,Electrical , Plumbing and others Internal and External services at Jamdoli,Agra Road,Jaipur Rajasthan
NBCC/SrED/RBG/Rajasthan/CRC/NIT/25-26/5-dated-15-09-2025
NBCC/SrED/RBG/Rajasthan/CRC/NIT/25-26/5-dated-15-09-2025
Open Tender-Domestic
Civil Works General
Jaipur, Rajasthan
₹11,800
₹24.5 L
15 Sept 2025
15 Sept 2025
7 Oct 2025
7 Oct 2025
1 Nov 2025
S.No. Description Total Amount(In Rs)
BILL OF QUANTITIES
S.No. DESCRIPTION OF ITEM UNIT QTY RATE(Rs) Amount (Rs)
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm
in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto
50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil
Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of
5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches,
2 2.25a plinth, sides offoundation etc. complete for all lift.
Filling available excavated earth (excluding rock) in trenches, plinth, sides
of foundations etc. in layers not exceeding 20cm in depth, consolidating
2.25 each deposited layer by ramming and watering, lead up to 50 and for all lift.
Surface dressing of the ground including removing vegetation and in-
2.28 equalities not exceeding 15 cm deep and disposal of rubbish, lead up to
50 m and lift up to 1.5 m.
2.28.1 All kinds of soil sqm 4000 34.15 136600.00
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -
All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources :
8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement
concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /
Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /
retard setting of concrete, to improve durability and workability without impairing strength; including pumping of
concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and
5 5.33 reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.
In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the
contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
All works upto plinth level Concrete of M25 grade with minimum cement
5.33.1 content of 330 kg /cum
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement
concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /
Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /
retard setting of concrete, to improve durability and workability without impairing strength; including pumping of
concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and
6 reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.
In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the
contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330
5.33.2 kg /cum
7 5.9 Centering and shuttering including strutting, propping etc. and removal of form for :
5.9.1 Foundations, footings, bases of columns, etc. for mass concrete sqm 121.00 392.15 47450.15
5.9.2 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3 Suspended floors, roofs, landings, balconies and access platform
5.9.4 Shelves (Cast in situ) sqm 100.00 927.25 92725.00
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers sqm 2894.00 736.40 2131141.60
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts sqm 1199.00 961.30 1152598.70
5.9.16.1 Edges of slabs and breaks in floors and walls Under 20 cm wide metre 1182.00 208.55 246506.10
5.9.19 Weather shade, Chajjas, corbels etc., including edges
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth
in: Cement mortar 1:6 (1 cement : 6 coarse sand) cum 300.00 7132.25 2139675.00
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above
9 6.4.2 plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above
10 6.13.2 plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry
100 mm/ 125 mm thick with Grade-1 AAC blocks of density 551 to 650
kg/cum conforming to IS:2185 (Part 3) in super structure above plinth
a 6.38 level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ).
The rate includes providing and placing in position 2 Nos 6 mm dia M.S.
bars at every third course of masonry work.
Digitally signed by ARUN
Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry
with 150 mm to 300 mm thick with Grade-1 AAC blocks of density 551 to
650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth
level up to floor V level with RCC band at sill level and lintel level with
approved block laying polymer modified adhesive mortar all complete
as per direction of Engineer-in-Charge. (The payment of RCC band and
reinforcement shall be made for seperately).
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per
12 4.13 square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly
soaked in kerosene oil.
13 2.34 Supplying chemical emulsion in sealed containers including delivery as specified.
2.34.1 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% litre 659.00 234.75 154700.25
Diluting and injecting chemical emulsion for Pre-CONSTRUCTIONAL anti-termite treatment (excluding the
14 2.35 cost of chemical emulsion) :
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including
2.35.3 drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the
existing floor :
13 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all
complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-
chambered frame, sach and mullion/coupler (where ever required) extruded profiles having minimum wall
thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm foe series R3 and R4 profiles conforming to EN :
12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape &
size as per CPWD Specification, uPVC extruded glazing beads, interlocks and inline sash adaptor (where ever
15 9.147.A required) of appropriate dimension, EPDm gasket , hardware, SS 304 grade fasteners of minimum 8 mm dia with
countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS
1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash &
mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners,
including drilling of holes for fixing haedware and drainage of water etc.
After Fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof sillicon
sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD
specification & direction of Engineer-in-charge. Section of steel reinforcement and cross sections of uPVC Profiles
to be as per design approved by Engineer-inCharge. Wire mesh/Glazing of plain/toughened/ laminated /double
glass unit with / without high performance coatings as per design requirements and conforming to IS :3548 & IS :
16231 shall be paid separately. Notes:- Structural design proof cheacked from a Government
Engineering Institute, to be provided by the manufacturer for :
(i) Sites with basic wind speed >45 m/Sec as per IS 875 - Part 3. (ii) Sites with structure height more than 20m for
all wind speeds.
Two track two panels sliding door with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder
coated handle on two panels along with multi-point locking system, adjustable nylon rollers with SS 304 body.
9.147.A1.2 Using R3 series with frame (55 mm & above)x (40 mm & above) & sach (30 mm & above ) x (55 mm &
above).(Height upto 1.8 metre).
Two track two panels sliding door with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder
coated handle on two panels along with multi-point locking system, adjustable nylon rollers with SS 304 body.
9.147.B1.2 Using R4 series with frame (64 mm & above)x (45 mm & above) & sach (44 mm & above ) x (85 mm &
above).(Height above 2.5 metre).
16 9.1.2 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and
fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener
shall be paid for separately).Sal wood cum 8.00 116520.30 932162.40
Providing and fixing ISI marked flush door shutters conforming to IS :
2202 (Part I) decorative type, core of block board construction with
frame of 1st class hard wood and well matched teak 3 ply veneering with
vertical grains or cross bands and face veneers on both faces of shutters.
9.20.1 35 mm thick including ISI marked Stainless Steel butt hinges
with necessary screws SQM 262.00 3473.85 910148.70
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door
18 9.23 shutters (over all area of door shutter to be measured).
Steel work welded in built up sections/ framed work, including cutting,
10.25 hoisting, fixing in position and applying a priming coat of approved steel
primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets,
gates and similar works Kg 4000.00 172.60 690400.00
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including
welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with
necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel
19 10.28 dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with
suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel
members shall be considered excluding fixing accessories such as nuts, bolts, fasteners
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish
with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046
20 9.127.1 Type S, including cost of adhesive of approved quality
Digitally signed by ARUN
Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and
wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6
graded stone aggregate 20mm nominal size). Nos. 488.00 228.85 111678.80
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC
22 9.96.1 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16
Providing and fixing aluminium tower bolts, ISI marked, powder coated (minimum thickness of powder coating
23 9.97 50 micron) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250x10 mm.
Providing and fixing aluminium handles, ISI marked, powder coated (minimum thickness of powder coating 50
24 9.100.1 micron) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm.
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than
grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc.
25 9.101.2 complete. Twin rubber stopper
Providing and fixing chromium plated brass curtain rod having wall
thickness of 1.25 mm with two chromium plated brass brackets fixed with
a 9.46 C.P. brass screws and PVC sleeves etc., wherever necessary complete
Providing and fixing aluminium die cast body tubular type universal
hydraulic door closer (having brand logo with ISI, IS : 3564, embossed
c 9.83 on the body, door weight upto 35 kg and door width upto 700 mm), with
necessary accessories and screws etc. complete.
Providing and fixing bright finished brass hanging type floor door stopper
with necessary screws, etc. complete.
Providing and fixing fire resistant door frame of section 143 x 57 mm
having built in rebate made out of 16 SWG G.I. sheet (zinc coating not
less than 120 gm/sqm) duly filled with vermuculite based concrete mix,
suitable for mounting 60 minutes fire rated door shutters. The frame is
fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround
the frame and fixing with dash fastener of approved size and make,
including applying a coat of approved brand fire resistant primer etc.
complete as per direction of Engineer-in-charge (Dash fastener to be
paid for separately).
Providing and fixing 50 mm thick glazed fire resistant door shutters of 60
minutes fire rating conforming to IS:3614 (Part-II), tested and certified as
per laboratory approved by Engineer-in-charge, with suitable mounting
on door frame, consisting of vertical styles, lock rail, top rail 100 mm
f 9.137 wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc
coating not less than 120 gm/sqm) duly filled FR insulation material and
fixing with necessary stainless steel ball bearing hinges of approved
make, including applying a coat of approved fire resistant primer etc. all
complete as per direction of Engineer-in-charge (panneling to be paid for
separately). each 10.00 7533.20 75332.00
Providing and laying integral cement based water proofing treatment including preparation of surface as required
for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat
cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and
approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including
cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to
115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound
26 22.7 conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5
(1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by
Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including
rounding of junctions of walls and slabs.
(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed
with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the
surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water
proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth
of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and
making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water
for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as
directed and specified by the Engineer-in-Charge :
With average thickness of 120 mm and minimum
22.7.1 thickness at khurra as 65 mm. sqm 450.00 1684.60 758070.00
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm
x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof
and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1 :4 (1 cement : 4 coarse
sand) and grouting the joints with mix of white cement & marble powder in ratio of 1 :1, including rubbing and
27 12.55 polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet
walls in the same manner.
28 13.4.2 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
Digitally signed by ARUN
29 13.5 15 mm cement plaster on the rough side of single or half brick wall of mix :
15 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) in single coat on rough side of single or half brick
8 mm cement plaster in two coats under layer 12 mm thick cement plaster
13.12 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster
1:3 (1 cement : 3 coarse sand) finished rough with sponge. sqm 2000.00 537.45 1074900.00
31 13.16.1 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
32 5.30 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. metre 12183.00 78.40 955147.20
B 5.30 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. metre 470.00 78.40 36848.00
Chequerred precast cement concrete tiles 22 mm thick in footpath &
courtyard, jointed with neat cement slurry mixed with pigment to match
the shade of tiles, including rubbing and cleaning etc. complete, on 20
mm thick bed of cement mortar 1 :4 (1 cement: 4 coarse sand).
Medium shade pigment using 50% white cement 50% Grey
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water
absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on
34 11.41A 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm
including grouting the joints with white cement and matching pigments etc., complete.
11.41A.1.2 Double Charge Size of Tile 800 x 800mm
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300
mm or more (thickness to be specified by the manufacturer), of 1st quality
conforming to IS : 15622, of approved make, in all colours, shades,
except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement
Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @
3.3 kg/ sqm including pointing the joints with white cement and matching
pigments etc., complete.
Providing edge moulding to 18 mm thick marble stone counters, Vanities
8.3 etc., including machine polishing to edge to give high gloss finish etc.
complete as per design approved by Engineer-in-Charge.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water
absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on
35 11.41A 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm
including grouting the joints with white cement and matching pigments etc., complete.
11.41A.3.2 Glazed Vitrified tiles Matt/Antiskid finish of size 600 x 1200mm
Providing and laying Polished Granite stone flooring in required design
and patterns, in linear as well as curvilinear portions of the building all
complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement
36 11.56.1 mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry
admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified
and as directed by the Engineer-in-Charge.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for
kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade,
colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with
white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing
to edges to give high gloss finish etc. complete at all levels.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the
manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as
approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3
38 8.31 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white
cement mixed with pigment of matching shade complete.
Providing and laying damp-proof course 40 mm thick with cement
concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural
sources : 4 graded stone aggregate 12.5 mm nominal size derived from
38 a 4.10 natural sources)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded
stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed
and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the
39 4.17 top smooth.
Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of
41 13.41 approved manufacturer and of required shade and colour all complete to achieve even shade and colour :
New work (two or more coats) over and including water
13.41.1 thinnable priming coat with cement primer having VOC content less than 50 gram/litre sqm 1100.00 185.65 204215.00
Wall painting with premium acrylic emulsion paint of interior grade, having
13.83 VOC (Volatile Organic Compound ) content less than 50 grams/ litre of
approved brand and manufacture, including applying additional coats
wherever required to achieve even shade and colour.
Digitally signed by ARUN
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:
42 13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and
43 13.80 manufacturer, over the plastered wall surface to prepare the surface even and smooth Complete.
French spirit polishing :
a 13.68 13.68.1 Two or more coats on new works including a coat of wood filler
Painting with synthetic enamel paint of approved brand and manufacture
b 13.61 to give an even shade :
13.61.1 Two or more coats on new work
Construction of Apron drain of size 150mm x 150mm with 115 mm brick wall in 1:6 (1 cement : 6 coarse sand)
having palstered with 20 mm thick Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of
neat cement & 150 mm thick lean concrete base in 1:4:8 (1 cement : 4 coarse sand : 8 Stone Grit) and 25 mm thick
cement concrete in 1:2:4 (1 cement : 2 coarse sand : 4 Stone Grit) above lean concrete with floating coat etc.
complete incl. cost of all etc. required for proper completion of work.
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse
sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with
12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making
45 12.22 and finishing the outlet complete.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A,
46 12.41 including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single
socketed pipes.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC
47 12.42 rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,
leaving 10 mm gap for thermal expansion.
12.42.1 Coupler
12.42.6 Shoe (Plain)
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by
means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick
work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less
Providing and laying in situ seven course water proofing treatment with
APP (Atactic Polypropylene) modified Polymeric memberane over roof
consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th
& 6th courses of bonding material @ 1.20 kg/sqm, which shall consist of
blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th
layers of roofing membrane APP modified Polymeric membrane 2.0 mm
thick of 3.00 Kg/sqm weight consisting of five layers prefabricated with
49 a 14.88 centre core as 100 micron HMHDPE film sandwiched on both sides with
polymeric mix and the polymeric mix is protected on both side with 20
micron HMHDPE film. 7th, the top most layer shall be finished with brick
tiles of class designation 10 grouted with cement mortar 1:3 (1 cement : 3
fine sand) mixed with 2% integral water proofing compound by weight of
cement over a 12 mm layer of cement mortar 1:3 ( 1 cement : 3 fine sand)
and finished neat (item of laying brick tiles shall be paid for separately).
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry
mixed with water proofing cement compound consisting of applying :
(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm.
This layer will be allowed to air cure for 4 hours.
50 22.5 (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126
kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.
(The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and
masonry with polymer mixed slurry.)
Providing and fixing GI Clip in Metal Ceiling System of 600x600 mm
module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted
steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre,
suspending the main C carrier of size 10x38x10 mm made of GI steel 0. 7 mm thick from the soffit with the help of
soffit cleat 37x27x25x1 .6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier
bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of
GI steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers
51 12.54.2 with the help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T
connectors have to be used. All sections to be galvanized@ 120 gms/sqm (both side inclusive), fixing with clip in
tiles into spring T with : GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and
0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive)
and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated
of thickness 60 microns (minimum), including factory painted after bending and perforation.
Digitally signed by ARUN
16.1 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating
earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making
good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
16.2 Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of
the maximum dry density (proctor density). 24.85 1491.00
16.3.1 Supplying and stacking at site.90 mm to 45 mm size stone aggregate Cu.M 60.00 2098.4 125904.00
16.3.2 63 mm to 45 mm size stone aggregate. Cu.M 60.00 1636.05 98163.00
16.3.3 53 mm to 22.4 mm size stone aggregate. Cu.M 60.00 1842.3 110538.00
16.4 Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform
thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper
grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of
coarse aggregate, watering and compacting to the required density . 1046.95 261737.50
16.43.1 Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement
content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate
proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever
required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling
to required slope/ camber, finishing with required texture, including steel Cu.M 55.00
form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction &
longitudinal joints ( 10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with
approved joint filler and sealants, complete all as per direction of Engineerin- charge (Item of joint fillers, sealants,
dowel bars with sleeve/ tie bars to be paid separately). 10529.35 579114.25
16.48.1 Painting road surface marking with adequate nos of coats to give uniform finish with ready mixed road marking
paint conforming to IS : 164, on bituminous surface in white/yellow shade, including cleaning the surface of all Sq.M 100.00
dirt, scales, oil, grease and foreign material etc. complete. New work (Two or more coats) 288.9 28890.00
16.50 Providing and fixing Glow studs of size 100x20 mm made of heavy duty body shall be moulded ASA (Acrylic
styrene Acryloretrite ) or HIP (High impact polystyrene) or ABS having electronically welded micro- prismatic lens
with abrasion resistant coating as approved by Engineer in charge. The glow stud shall support a load of 13635
kg tested in accordance with ASTM D4280. The slope of retro- reflective surface shall be 35 (+/-5) degress to
base .The reflective panels on both sides with at least 12 cm of reflective area up each side. The luminance Each 80.00
intensity should be as per the specification and shall be tested as described in ASTM I: 809 as recommended in
BS: 873 part 4 : 1973. The studs shall be fixed to the Road surface using the adhesive conforming to IS, as per
procedure recommended by the manufacturer complete and as per direction of Engineer-in-charge.
16.59.1 Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to
be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type -
IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-
lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall
be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with
suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm
along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a ertical
post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the Sq.M 50.00
bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required
size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of
approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be
painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy
paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing ,
specification and direction of Engineer—in-charge.
4.1.3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and
shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
16.60.1 Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium
sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective
sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-incharge, letters, borders etc. as
per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate
by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of
ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium
alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows Sq.M 90.00
along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey
colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of
rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same
in position all complete as per drawings, specification and direction of the engineer-in-charge.(Structural frame
work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for
16.63 Providing, laying and making kerb channel 30cm wide and 50mm thick with cement concrete 1:3:6 (1 cement: 3
coarse sand:6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal
size well rammed and consolidated and grouted with fine sand including finishing the top smooth etc. complete
and as per direction of Engineer-in-charge. 558.3 72579.00
16.68 Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by
block making machine with strong vibratory compaction, of approved size, design & shape, laid in required
colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand Sq.M 550.00
etc. all complete as per the direction of Engineer-in-charge.
16.69 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position
to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand) including
making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm),
including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge
(length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by
Engineer-in-charge). 10117.6 505880.00
19.6.2 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of
cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm R.M 100.00
Horticulture Supplying and stacking of good earth at site including royalty and carriage upto 1 km (earth measured in stacks
and Land will be reduced by 20% for payment).
Horticulture Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Officer-in-
and Land charge (Cost of sludge, dump manure and / or good earth to be paid separately).
Total of Schedule Items 115961207.48
HORTICULTURAL WORKS
2.1 Trenching in ordinary soil upto a depth of 60 cm including removal and stacking of serviceable materials and
then disposing of by spreading and neatly levelling within a lead of 50 m and making up the trenched area to
proper levels by filling with earth or earth mixed with sludge of/and manure before and
after flooding trench with water (encluding cost of imported earth,sludge or manure). 119.00 95200.00
2.2 Supplying and stacking of good earth at site including royalty but excluding carriage (earth measusred in stacks
will be reduced by 20% for payment). 803.75 643000.00
2.4.3 Supplying and stacking a' site dump manure from approved
source, excluding carriage (manure measured in stacks will be Cu.M 46.25
reduced by 8% for payment)Screened through sieve of l.S. designation 4.75 mm 491.65 22738.81
2.5 Rough dressing the trenched ground including breaking clods. Sq.M 1850.00 2.3 4255.00
2.6 Uprooting weeds form the trenched area after 10 to 15 days of
its flooding with water including disposal of uprooted vegetation. 7.45 13782.50
2.7 Fine dressing the ground Sq.M 1850.00 5.6 10360.00
Digitally signed by ARUN
2.8 Spreading of sludge, dump manure or/and good earth in
required thickness (Cost of sludge, dump manure or/and good Cu.M 1156.25
earth to be paid separately). 79.7 92153.13
2.9 Mixing earth and sjudge or manure in porportion specified or directed. Cu.M 1156.25 55.7 64403.13
2.10.1 Grassing with 'Doob' grass including watering and maintenance of the lawn for 30 days or more tili the grass
forms a thick lawn free form weeds and fit for mowing including supplying good earth if needed.In rows 15 cm Sq.M 1500.00
apart in either direction. 26.95 40425.00
2.14.1 Digging holes in ordinary soil and refilling the same with excavated earth mixed with manure or sludge in the ratio
of 2:1 by volume (2 parts of stacked volume of earth after reduction by 8%) flooding with water, dressing
including removal of rubbish and surplus earth. if any with all leads and lifts (cost of manure, sludge or extra good
earth if needed to be paid for separately):Holes 1.2M dia, and 1.2m deep 362.75 11608.00
2.14.2 Holes 60 cm dia. And 60 cm deep Nos 64.00 155.5 9952.00
2.16 Providing and fixing M.S. flat iron tree guard 60 cm dia. And 2m high above ground level formed of 4 nos. 25x6
mm and 8 nos. 25x3 mm vertical M.S. flats hvetted to 3 nos. 25x6 mm M.S. flat iron rings in two halves, bolted
together with 8mm dia. And 30 mm long bolts inclujding painting two coats with paint of approved brand and
manufacture over a coat of priming complete in all respects. 6507.55 325377.50
2.19.1 Edging with bricks laid dry length wise including excavation, refilling, consolidating with hand packing and
spreading susrplus earth neatly within a lead of 50m.Common burnt clay F.P.S. (non modular) bricks of class R.M. 350.00
designation 7.5 48.85 17097.50
2.11 Renovating lawns including weeding, cheeling the grass, forking the grond, top dressing with sludge or manur,
mixing the same with forked soil, watering and maintaining the lawn for 30 days or more till the grass forms a
thick lawn free from weeds and fit for mowing and disposal of rubbish as directed, including supplying good
earth if needed but excluding the cost of sludge or manure. 52.45 52450.00
2.12 Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm removing all weeds and other
growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh
growth after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all
leads and lifts. 92.9 92900.00
2.13 Preparation of beds for headging and shrubbery by excavating 60 cm deep and treanching the excavated base
to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in
the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge
or manure after reduction by 8%) flooding with water, filling with earth if necessary, watering and finally fine Cu.M 40.00
dressing, levellinjg etc. including stacking and disposal of materials declared unserviceable and surplus earth
upto 1.5m complete (cost of sludge, manure or extra earth to be paid for separately).
Total of Schedule Items 1509296.57
1.0 SCHEDULE OF QUANTITIES
S. No. Description of Item Qty. Unit Rate Amount
Supply, Installation, Testing & Commissioning of
following accessories suitable for upgradation of
existing Sewage Treatment Plant of 50 KLD with
Advanced Eco Reactor (AER) Technology:-
b) BOD : upto 100 mg/l
c) Suspended solids (SS) : upto 100 mg/l
d) Oil & grease : upto 10 mg/l
e) COD : upto 250 mg/l
(B) Effluent (Final)
a) BOD : Not more than 10 mg/l
b) Fecal Coliform : Not more than 230 (MPN/100)
c) Total Suspended Solids : Not more than 20mg/l
e) COD : Not more than 50 mg/l
(C) The plant should be able to operate efficiently at
10% of design flow and should be suitable for
(D) There should be no daily/weekly/monthly sludge
1 Pre Treatment
1.1 Bar Screen Chamber
SITC of Coarse Type SS Bar Screen (SS 304 fabricated)
of size 700MM X 600MM with 10MM-12MM
opening along with SS Frame for lifting to block the in
organics like bottles, glass, polythenes etc complete as
(MOC - SS 304, Fabricated) Each 2 46891 93782.00
2 Secondary Treatment
SITC ofPumps for transferring
submersible sewagepumps
Sewage Transfer to AER(Motor
Capacity: 1.0 HP) suitable for handling upto 20mm
solid particles having a liquid discharge rate of 2500
Ltr/hr (each) at a head of 12 metres incorporating C.I.
casing, CI impeller, CI motor body with Nylon lifting
rope 16mm-20mm thick and suitable for operation on
3-phase 415- Volt AC supply with similar
3 Nos Pump - [02 Working + 01 SB] complete etc. as
2.2 Living Soil Medium
Supply of 200 kgs of living soil medium; a specialized
microbe pre-treated media formulated using specially
bred catalyst culture, sugar & protein source, and
fermented for 24 hrs, sun dried, sieved and packed for
creating required ecosystem in the Advanced Eco
Reactor including providing technical know-how for
project execution.
2.3 Organic Biosorption Media
Digitally signed by ARUN
SITC of 4 tons of Organic biosorption media consisting
of carbon rich material along with unloading & filling
into the Advanced Eco Reactor.
2.4 Plastic Crates
SITC of Plastic Crates for housing of living soil medium
and organic bioadsorption media
Unit Size : 520 mmX 360mm X 280 mm; MOC:
Recycled Plastic Each 180 725 130500.00
2.5 Green Zoning
SITC of planting material, growth promoters and
enhancers etc for green zoning Job 1 108368 108368.00
2.6 Probiotic Bacterial culture
Supply & inoculation of probiotic microbial mother
culture for development of microbial bio-film on the
surface of the inert media and for control of sludge
during operation period.
Digitally signed by ARUN
SITC of ASTM approved UPVC Sch 40 Piping work for
with all necessary accessories like ball valves, b/f
valves, elbow, unions, flange, Non returnable valves
MTA, FTA, coupler, tees, reducers, pressure gauge,
clamps, fastners etc for making the AER grid complete
as required along with 02 no. helix disc filter and ISI
marked PVC pipe for taking the AER outlet into the UG
4 Electrical Work
4.1 STP Control
SITC Panel Motor Control Panel made of 2mm
thick CRCA sheet duly powder coated with necessary
switch gears such as INCOMER MCCB of required amp
with outgoing switch gears for auto operation of 02 no.
sewage pumps, 1 Nos. Ozonation System, 02 nos.
Treated water pumps along with necessary MCBs, VIF
meter, indication light, protection MCB and DOL
Starter with MCB over load relay, Single Phase
Preventer relay, on-off light push button, auto - manual
selector switch, cyclic timer for auto change-over of
pumps, dry run protection.
4.2 Unarmoured/Flexible Copper Control Wiring
SITC of unarmoured/flexible Copper control wiring of
suitable size in pvc channel/conduit/MS pipe from STP
panel to all the pumps and other electrical equipments
complete as required.
5 Instrumentation
SITC of online pH meter to measure acidity or alkanity
of the treated water etc. as required.
5.2 Flow Meter
SITC of Electromagnetic Flow meter suitable for flow
rate of 50 KLD plant treated water complete as reqd.
5.3 Float switch
SITC of baloon type PP liquid water level controller for
all pumps to ensure respective pumps start/stop
automatically to prevent any unwanted
overflow/damage of pumps with 3 mtrs wire complete
6.1 Ozonation System for Disinfection
Ozone generation system (capacity 50 gms) with
recirculation system including recirculation CPVC
piping & recirculation pump with servo stabiliser for
disinfection & polishing of waste water.
7 Treated water pumps for transferring treated
SITC foropenwell
non-potable use
submersible pumps (Motor Capacity:
7.1 2.0 HP) having a liquid discharge rate of upto 8000
Ltr/hr (each) at a head of 24 metres incorporating C.I.
casing, CI impeller, CI motor body with Nylon lifting
rope 16mm-20mm thick and suitable for operation on
3-phase 415- Volt AC supply with similar
2 Nos Pump - [01 Working + 01 SB] complete etc. as
SUB HEAD-: II (Operation & Maintenance of 100 KLD STP based on Advanced
Eco Reactor (AER) Technology)
8 O&M for 12 Months
8.1 SITC of PVC tank (capacity: 1000 litres) fitted with ball
valve and dosing pipe for dosing of activated bacterial
culture in the collection tank
Operation & preventive maintenance of STP by 01 no. Each 2 20476 40952.00
8.2 operator all days in a month (8.5 hrs shift). The cost
a. Operation of STP
b. Dosing of activated probiotic bacterial culture (100
d. Mainentenance of STP log book and dosing register
e. Repair & maintenance i/c replacement of defective
parts i/c rewinding of motor, repair of pump, pipe,
panel or any other electrical or mechanical equipment
Digitally signed by ARUN
Detailed Estimate Based On DSR-2022 ,DSR 2025 and Market Rate
Internal Electrical Works
Rate as Amount as Amount as
per DSR Rate as Per Amount as per
Sr.No. Sch.No. Particulars Qty Unit per DSR per DSR Per
2025(Rs Market(Rs) DSR 2022(Rs)
2022(Rs) 2025(Rs) Market(Rs)
Wiring for light point/ fan point/ exhaust fan point/ call bell
point with 1.5 sq.mm FRLS PVC insulated copper conductor
single core cable in surface / recessed medium class PVC
1 1.10.3 conduit, with modular switch, modular plate, suitable GI box 672 Nos. 1,467.00 - 9,85,824.00 -
and earthing the point with 1.5 sq.mm FRLS PVC insulated
copper conductor single core cable etc. as required.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface /
recessed medium class PVC conduit, 2 way modular switch,
2 1.11 modular plate, suitable GI box and earthing the point with 1.5 16 Nos. 1,562.00 - 24,992.00 -
sq.mm FRLS PVC insulated copper conductor single core cable
etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC
insulated copper conductor single core cable in surface/
recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC
3 1.12 insulated copper conductor single core cable for loop earthing as required. 5565 Meter 334.00 - 18,58,710.00 -
Wiring for circuit/ submain wiring alongwith earth wire with the
following sizes of FRLS PVC insulated copper conductor, single core cable in
4 1.14 surface/ recessed medium class PVC conduit as required. - - -
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Supplying and drawing following pair 0.5 mm dia FRLS PVC
insulated annealed copper conductor, unarmored telephone
5 1.18 cable in the existing surface/ recessed steel/ PVC conduit as - - -
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper
conductor PE insulated, shielded with fine tinned copper braid and protected with
6 1.19 PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 385 Meter 47.00 - 18,095.00 -
Supplying and fixing of following sizes of medium class PVC
conduit along with accessories in surface/recess including
7 1.21 cutting the wall and making good the same in case of recessed - - -
conduit as required.
Supplying and fixing following modular switch/ socket on the
existing modular plate & switch box including connections but
excluding modular plate etc. as required.
a 1.24.6 Telephone socket outlet 19 Each 148.00 - 2,812.00 -
b 1.24.7 TV socket outlet 7 Each 148.00 - 1,036.00 -
c RA-1 RJ45 socket cat 6 with shutter 84 Each 497.46 - - 41,786.82
Supplying and fixing two module stepped type electronic fan
9 1.25 regulator on the existing modular plate switch box including 202 Each 369.00 - 74,538.00 -
connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, GI box alongwith
10 modular base & cover plate for modular switches in recess etc. - - -
Supplying and fixing suitable size GI box with modular plate and cover in front
on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket
11 1.31 outlet and 5/6 A modular switch, connections etc. as required. 139 Each 477.00 - 66,303.00 -
Supplying and fixing suitable size GI box with modular plate and cover in front
12 1.32 on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A 96 Each 586.00 - 56,256.00 -
modular socket outlet and 15/16 A modular switch, connections etc. as required.
Installation ,Testing, Commissioning of wall bracket /ceiling
fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per
13 1.35 fitting, complete with all accessories including connections etc. as required. 0 Each 119.00 - - -
Digitally signed by ARUN
Supplying and fixing stiff pendent with 300 mm long, 20 mm dia X 1.6 mm thick
steel conduit, aluminium cast back plate and brass holder complete, including
14 1.36 wiring the down rod with 1.5 sq. mm FRLS PVC insulated, copper conductor, Each 304.00 - - -
single core cable and painting etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase,
15 1.38 230 V, complete as required. 20 Each 99.00 - 1,980.00 -
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/
16 1.53 recessed Steel/ PVC conduit as required. - - -
Wiring for group controlled (looped) light point/fan
point/exhaust fan point/ call bell point ( without independent
switch etc.) with 1.5 sq. mm FRLS PVC insulated copper
17 1.55 conductor single core cable in surface/ recessed PVC conduit, - - -
and earthing the point with 1.5 sq. mm FRLS PVC insulated
copper conductor single core cable etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front
on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular
socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For
light plugs to be used in non residential buildings).
Supplying & fixing suitable size GI box wih modular plate and
cover in front on surface or in recess including providing and
19 1.57 fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve 63 Each 727.00 - 45,801.00 -
including connections, painting etc. as required.
Supplying and fixing following way, horizontal type three pole
and neutral, sheet steel, MCB distribution board, 415 V, on
surface/ recess, complete with tinned copper bus bar, neutral
20 2.4 bus bar, earth bar, din bar, interconnections, powder painted - - -
including earthing etc. as required. (But without
MCB/RCCB/Isolator)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
21 2.10 DB complete with - - -
connections, testing and commissioning etc. as required.
c 2.10.5 Three Phase & Neutral 8 Each 1,228.00 - 9,824.00 -
Supplying and fixing following rating, double pole, (single phase
and neutral), 240 V, residual current circuit breaker (RCCB),
22 2.14 having a sensitivity current 30 mA in the existing MCB DB - - -
complete with connections, testing and commissioning etc. as
Supplying and fixing 63Amp, four pole, (three phase
and neutral), 415 volts, residual current circuit breaker (RCCB),
23 RA-3 having a sensitivity current 300 mA in the existing MCB DB 2 Each 6,026.70 - - 12,053.40
complete with connections, testing and commissioning etc. as
required. Similar to Legrand or equivalent.
Supplying and fixing 40/63A rating, 415 V, 10 kA, "C" curve, miniature circuit
breaker suitable for inductive load of Four poles in the existing MCB DB
24 complete with connections, testing and commissioning etc. as required. Similar 9 Each 2,657.56 - - 23,918.06
to Legrand DX3 AC MCBs or equivalent.
Supplying and installing following size of perforated painted
with powder coating M.S. cable trays with perforation not more than 17.5%, in
25 4.1 convenient sections, joined with connectors, suspended from the ceiling with M.S. - - -
suspenders including bolts & nuts, painting suspenders etc as required.
a 4.1.1 100 mm width X 50 mm depth X 1.6 mm thickness 100 Each 543.00 - 54,300.00 -
b 4.1.4 300 mm width X 50 mm depth X 1.6 mm thickness 100 Each 777.00 - 77,700.00 -
c 4.1.7 600 mm width X 50 mm depth X 1.6 mm thickness 30 Each 1,366.00 - 40,980.00 -
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick
26 5.4 including accessories, and providing masonry enclosure with 4.0 Each 7,472.00 - 29,888.00 -
cover plate having locking arrangement and watering pipe of
2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm
thick including accessories, and providing masonry enclosure
with cover plate having locking arrangement and watering pipe
of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre
below ground as strip earth electrode, including connection/
28 5.9 terminating with G.I. nut, bolt, spring, washer etc. as required. 150.0 Meter 144.00 - 21,600.00 -
(Jointing shall be done by overlapping and with 2 sets of G.I. nut
bolt & spring washer spaced at 50mm)
Digitally signed by ARUN
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre
below ground as strip earth electrode, including connection/
29 5.8 terminating with nut, bolt, spring, washer etc. as required. 50.0 Meter 972.00 - 48,600.00 -
(Jointing shall be done by overlapping and with 2 sets of brass
nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I.
30 5.1 pipe from earth electrode including connection with brass nut, 100 Meter 1,551.00 - 1,55,100.00 -
bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I.
pipe from earth electrode including connection with G.I. nut,
bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in
32 5.15 recess for connections etc. as required. 100 Meter 244.00 - 24,400.00 -
Providing and fixing 6 SWG dia G.I. wire on surface or in recess
for loop earthing along with existing surface/ recessed conduit/
submain wiring/ cable as required.
LED Down lighter (SMD Type) (System lumen efficacy >135 lm/Watt)
Supplying, installation, Testing & Commissioning of LED Recessed /
surface Down lighter (Round /square/Rectangular) SMD type of following body
material with PMMA and prismatic diffuser and construction as per IS : 10322
with driver as per the requirement with Driver efficiency >85%, Operating
voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40
deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit
protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare
Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver
DSR & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of
2025 initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 - -
1.3 report, CCT 3000°K / 4000°K / 5700°K / 6000°K /6500°K (As per ANSI Bin) ,
SDCM(Standard Deviation Color Matching) <3, Maximum power consumption
should not more than the specified rating and Fixture shall be of relevant BIS
standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name
Engraved/ Embossing/ Screen printing on housing. OEM must have its own in
house NABL lab setup for all testing facilities for LED fixtures. complete in all
respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor
single core cable and earthing etc. as required
with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt
output . LM79 & LM80 Test report from NABL lab for all testing required for
LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as
approved by Engineer-in-Charge as per requirement. (Thermal management: heat
sink of aluminum housing such that LED junction temperature shall not rise
Powder coated die cast / Extruded aluminum Body including trim.
SITC of 12W Extruded aluminium batten available in 2ft run length with
multiple lumen packages and suitable for surface, wall & conduit ounting (with
accessories). similar to Philips Type HSN Code MRP (INR) BN 021 LED12S
6500 PSU GR or equivalent.
Supply and fixing of water tight oblong 10 Watt LED bulkhead luminaire having
pressure diecast housing with driver set confirming to IP 65 and above Protection,
IK08, High purity / transmisivity UV stablized Non yellowish diffuser/ Reflector for
uniform light distribution, ditachable driver set, suitable for 24hrs continuous operation
complete in all respect.
1200 system lumen, >120lm/W, PF>0.95, CRI>70, >300V, over voltage protection,
4KV internal surge protection with 5 year warrenty. CAT-AAA
Digitally signed by ARUN
LED Batten light (System lumen efficacy >135 lm/Watt)
Supplying, installation, Testing & Commissioning of LED surface mounted
Batten light of following body material and construction as per IS : 10322 with
driver (Replaceable) as per the requirement with Driver efficiency >85%
,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -
15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short &
Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker
free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry),
of minimum 50000 Burning Hours with , 70% of initial Lumen
maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/
6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching)
<3, Maximum power consumption should not more than the specified rating
and Fixture shall be of relevant BIS standard and trade mark certificate (
T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen - -
printing on housing. OEM must have its own in house NABL lab setup for
all testing facilities for LED fixtures. complete in all respect i/c
connections with 1.5 sq mm FRLS, PVC insulated copper conductor
single core cable and earthing etc. as required with Minimum 5 year OEM
warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test
report from NABL lab for all testing required for LED fixtures as per BIS
shall be submitted. Shape size and CCT shall be as approved by Engineerin-
Charge as per requirement. (Thermal management: heat sink of
aluminum housing such that LED junction temperature shall not rise above
DSR Powder coated die cast /Extruded aluminum Body (Thickness ≥ 1.20
LED Panel light 2x2 ft., (System lumen efficacy >135 lm/Watt)
Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of
following body material and construction as per IS : 10322 with driver as per the
requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt,
freq 50/60 hz, Operating temp range -15 deg to 40 deg
centigrade, internal surge protection of 2.5 KV with Short & Open circuit
protection,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare
Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver
& electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial
Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K
/6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color
DSR Matching) <3, Maximum power consumption should not more than the specified
2025 rating and Fixture shall be of relevant BIS standard and trade mark certificate - -
1.8 (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/Screen printing
on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC
insulated copper conductor single core cable and earthing etc. as required with
Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output .
LM79 & LM80 Test report from NABL lab for all testing required for LED
fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved
by Engineer-in-Charge as per requirement. (Thermal management: heat sink of
aluminum housing such that LED junction temperature shall not rise above
LED Panel light 1x4 ft., (System lumen efficacy >135 lm/Watt)
Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of
following body material and construction as per IS : 10322 with driver as per the
requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt,
freq 50/60 hz, Operating temp range -15 deg to 40 deg
centigrade, internal surge protection of 2.5 KV with Short & Open circuit
protection,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare
Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver
& electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial
Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K
/6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color
Matching) <3, Maximum power consumption should not more than the specified
MR rating and Fixture shall be of relevant BIS standard and trade mark certificate - -
(T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/Screen printing
on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC
insulated copper conductor single core cable and earthing etc. as required with
Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output .
LM79 & LM80 Test report from NABL lab for all testing required for LED
fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved
by Engineer-in-Charge as per requirement. (Thermal management: heat sink of
aluminum housing such that LED junction temperature shall not rise above
Digitally signed by ARUN
Supply of Suspended 4ft UGR<19 Linear fixture for Conference hall made with
Extruded Aluminium housing with system lumen of 3800lm & system efficacy of
>=115lm/watt, with continuous mounting using flexible connectors for making
the unique flexible arrangement/patterns of continuous luminaires. The flexible
connector shall be available in single link, bilink, trilink, and quad link to have
multiple possibilities of patterns. The luminaire shall have a rated system lifetime
of 50,000 burning hours at L70B50 with a batwing distribution. The luminaire
should have a color temperature of3000K/ 4000K/6500K and CRI>80/90. The
luminaire shall meet IP20 rating with THD<10% and PF >=0.9, SDCM<3,
working temp. range of -20°C to 40°C, length size of 1200mm, Surge protection
upto 2KV. The fixture design should be with flicker free operations ripple <5%,
comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in
MR Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 20.00 Each 33,805.00 6,76,100.00
ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, EMI/EMC Compliant.
The luminaire driver shall be of the same make/manufacturer of LED.
Manufacturer shall have inhouse lab approved by NABL or ministry of science of
govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL
accredited lab to verify above parameters. Both the fixture and Driver should have
separate BIS approval.
Supply of Deep Recessed low glare LED Downlighter with cut off angle 38°
made up of pressure die cast aluminum housing with high quality glossy facetted
Al reflector and PDC Aluminium external Rim. The luminaire shall have
minimum efficacy at System level approx 120 lumens/watt with system Lumens
750lm & wattage 6W, Life of fixture : 50000 burning Hrs. @ L70B50 Lumen
maintenance, CCT of 3000K/4000K/5700K/6500K,sdcm<=5, CRI Ra >=80, PF
≥0.95, an Operating working temp range 0°C < Ta < 45°C & operating Voltage
MR Range of 140-270 V AC, 50Hz. Minimum Internal Surge Protection 2.5KV, 20.00 Each 2,535.00 50,700.00
THD≤ 10%. Dimensions: 125mm cut out, OD137mm x 85mm. The beam angle
shall be 36deg/60deg.The product shall be with Class B serviceability and shall
be RoHS compliant. Manufacturer shall have inhouse lab approved by NABL or
ministry of science of govt of India. LM 79 and LM80 reports need to be
submitted from a NABL/UL accredited lab to verify above parameters. Both the
fixture and Driver should have separate BIS approval.
Supply of Standalone linear Channel LED suspended luminaire with up-down
distribution, 33% Up and 66% down, with minimum bezel and Sleek propostion
Wide 120mm x 45mm height and 1200mm length with extruded aluminium
housing and high polycarbonate/PS diffuser. LED Used shall be SMD type with
Minimum system Lumens 3300 @28W & efficacy upto 120lm/W,Life of fixture :
50000 burning Hrs. @ L70B50 Lumen maintenance, CCT of 4000K/6500K
(SDCM<=5), CRI Ra ≥80, PF ≥0.95, THD≤10%, an Operating working temp
range : -10°C < Ta < 45°C & operating Voltage Range of 140-270 V AC.
Minimum Internal Surge Protection 4.0KV. The fixture design should be with
flicker free operations ripple <5%, comply to IEC61000-3-2 ed.3.2, 2009 for
MR Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 20.00 Each 5,634.00 1,12,680.00
2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and
IEC61547 ed.2.0, 2009. The luminaire driver shall be of the same
make/manufacturer as that of LED luminaires. The luminaire shall be Class B
Serviceability, Manufacturer shall have inhouse lab approved by NABL or
ministry of science of govt of India. LM 79 and LM80 reports need to be
submitted from a NABL/UL accredited lab to verify above parameters. Both the
fixture and Driver should have separate BIS approval. Dimension should be LBH
Recessed PIR Motion Sensor Similar to Wipro Make : GLPS01R010HA or equivalent
Brush Less Direct Current (BLDC) Motor
Supply, Installation, Testing and Commissioning of ceiling fan with Brush
Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal
(Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit,
safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service
Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-
2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably
mobile app based) for speed control and all remaining
accessories including safety pin, nut bolts, washers, temperature rise=75
degree C (max.), insulation resistance more than 2 mega ohm, suitable for
230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan
Supply, earthing etc. complete as req
1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min
Supply and fixing hexagonal Round G.P.fan box approved make made up of 1.0
mm thick ISI Marked G.P.sheet spot welded Four to Eight holes for pipe entry
DSR of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made
Civil upper & lower cover duly screwed. Fixing with wiring conduit laid in the R.C.C.
2023 roof before concreting alongwith supply of all material, labour, T&P etc.
10.18 required for proper completion of the work.
Digitally signed by ARUN
Supply Installation Testing and Commissioning of 400mm sweep 1500RPM
energy efficient BLDC fan with double ball bearing for longer life similar to CGE
RENESA or equivalent.
Lightning Arrestor Work - - -
Lightning Arrestor: Supply, installation, testing and commissioning of External
Lightning wide area protection system based on Eaarly Streamer Emission (ESE)
technology. Device shall emit electromagnetic impulse in the form of a streamer
into the air microseconds earlier than naturally formed streamers. Device confirmg
to NFC 17-102 and UNE 21186 Standards. Appropriate non penetrating
mounting arrangement. The device shall be mounted at suitable clear to the
highest point on the roof top. (Model selected shall give coverage of 79 M radius
@ min 5M height from terrace)
Down conductor:Supply, installation, testing and commissioning of 70 Sqmm
46 MR twisted 19-Strand, bare Cu cable on surface/wall / as per site requirement and 60 Metre 2,510.92 - - 1,50,655.32
complete in all respect.
Lightning Counter :Supply and installation of counting the number of lightning
strikes without any power supply.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm
thick including accessories, and providing masonry enclosure
with cover plate having locking arrangement and watering pipe
of 2.7 metre long etc. with charcoal/ coke and salt as required.
49 MR Test Link :Supply and installation of test link in weather proof IP 65 BOX. 3 Each 2,832.00 - - 8,496.00
Supply, installation, testing and commisioning of 2 x 25W LED Aviation
abstruction light medium bay type 62, complete with lamp, lamp holder,
50 MR Condenser necessary connecting wire, 1 X 25 AV with all necessary hardware, 1 Each 12,279.08 - - 12,279.08
accessories as required for complete installation. Rate shall include the cost of
necessary steel structures , fixing arrangements in this item. Refer drawing.
Online UPS- Input supply: Three Phase, Output supply: Three Phase
Supplying, installation, Testing & Commissioning of of following capacity at full
load (Unity Power Factor) at operating temperature 0 to 40 deg C,
Relative humidity 0 to 95%, Online double conversion true sine wave
Uninterrupted hot swappable (allow for the replacement or addition of
battery modules without shutting down the entire system) modular Power
Supply (UPS) system with N+1 modules (N denotes total number of moduels
requird for rated capacity). The UPS shall include a Rectifier, inverter, battery
bank suitable for 30 minutes back up (Battery VAH capacity shall not be less
than 1600 VAH per KVA of UPS rating per Hour backup time) on full load
51 (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch - -
alongwith provision for manual bypass, suitable isolation transformer for
additional protection against neutral faults etc. UPS shall have inbuilt
phase sequence correction. The UPS systems offered are to be of the latest
technology with Digital Control Microprocessor based for reliable operation
using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter
(3 Level) with PWM (Pulse Width Modulation). The quality of design,
manufacturing and inspection process should confirm to the relevant International
standards such as IEC/EN/VDE. The operating efficiency of the UPS systems
shall be >96% while operating on battery mode and delivering quality power to - -
the 100% non-linear loads. Current total harmonic effect(ITHD) on the input grid
shall be < 5% at 50 %load. (The required LC (
inductor (L) and a capacitor (C)) filters shall be included in UPS cost),
extreme power factor kit to be included to limit the input power factor (PF) to
0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva
rating x 1 ), however UPS shall be suitable to take load at 0.7 laging to 0.7
leading power factor loads. UPS shall be suitable for incoming supply AC :
3Phase 400V +/-20%, 50 Hz +/-5 Hz, AC Output voltage: 3Phase 415 Volt, 50
Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins, Sine wave output. Non
condensing, noise level less than 60db at 1 meter distance, protections: Input
Under voltage over voltage, abnormal out voltage, battery over charging, output
over current, short circuit protection, battery deep discharge protection, 10KV - -
surge. UPS must comply with low voltage electromagnetic compatibility (EMC)
achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and
Frequency Independent (VFI)-type UPS. Communication RS232/RS485/SNMP
port open protocol for BMS
Digitally signed by ARUN
integration, all hardware & software for iOT Communication as per approved by
Engineering in charge. Required battery racks and interconnecting copper
conductor cables of suitable size and connectors and all required accoseries are
inclusive of the cost). This system must provide a means for logging and alarming
of all monitored points plus email notification. Forced air-cooling with integral
inbuilt fans with redundancy (if one fan fail UPS should be able to handle at least
80% of the load, Noise Level 65 DB at 1 meter distance. The system shall be in - -
compliance IEC 62040- 1,2 & 3, IS: 16242 and CPWD Specification. Display
Panel (minimum) (In-build 5 inch or more LC Display / LED ) to display : a)
Input: Voltage, current, Frequency. b) Bypass: Voltage, Frequency. c) Output:
Voltage, frequency, Current.
d) Battery: Voltage, Capacity. e) Load: KVA, KW, Percentage.
f)Temperature: STS, Inverter, PFC. g) Event Logging & Statistical Data (On
LCD/LED): UPS should capture and display up to 3000 events like: Over
temperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload / Short-circuit /
Device Fail / Inverter Fail / Rectifier Fail / Bypass Fail, etc. h) Statistical Data:
No. of power failures / Transfers to Bypass / Total Running time, etc. i) Mains
Mode of Operation /Battery Mode of Operation / Bypass feeding the load /UPS
Fault /Battery charging and discharging, overload, battery voltage and battery
DSR capacity. j) Audible Alarms : Mains Failure, Battery Low Alarm, UPS Overload,
2025 Fault, Shutdown, Input Over, Under Voltage, Output Over, Under Voltage, - -
5.2 Battery Over, Under Voltage, Over Load and short circuit, Over Temperature.
The UPS should have QR code which should contain drawing, test report OEM
manual,Geo- Tag of manufacturing location etc
40KVA (Each Power module shall be < 10 KVA) 5,99,469.00 -
Digitally signed by ARUN
Project - Proposed Composite Regional Centre (CRC) At Jamdoli, Agra Road, Jaipur (Rajasthan).
Name Of Work -CCTV Surveillance System Work
Rate as per D.S.R. 2022
Sr.No. Particulars Sch.No. Qty Unit MR Rate(Rs) AS PER MR Amount(Rs)
SUB HEAD :1 CCTV Surveillance Work - -
Supplying and drawing of UTP 4 pair CAT 6 DSR
1 LAN Cable in the existing surface/ recessed Steel/ 2022 - -
PVC conduit as required. 1.54
Supplying, installing, testing and commissioning
4 of I/O(Information outlet ) for CAT6 Cable MR 41.00 Nos 237.50 9,737.50
Supplying, installing, testing and commissioning
of 6 U wall mount rack with fans , 2 cable
6 managers , satationary shelf , 2 Nos of hardware MR 3.00 Nos 12,462.10 37,386.30
Weatherproof canopy with mounting arrangement
to safely mount Jackpanel and PoE Switch.
Supplying, installing, testing and commissioning
of 42 U wall mount rack with fans , 2 cable
8 managers , satationary shelf , 2 Nos of hardware MR 1.00 Nos 81,384.60 81,384.60
S/I/T/C of 24 port 10/100/1000 Base T
Standalone Gigabit Switch Make Dlink/Amp with
active and passive components, punching,
complete in all respect
Supply, Installation, Testing & Commissioning of
i7 CPU with latest generation windows 10 and
above, 1TB SSD and 500GB RAM.
Supply, Installation, Testing & Commissioning of
CCTV Client Operator Station with 1 No.of 55”
12 LED Display - Complete as per specifications MR 2.00 Nos 92,482.50 1,84,965.00
Supplying, installing, testing and commissioning
13 of HDMI to HDMI Cable. MR 2.00 Nos 1,424.05 2,848.10
Supply Installaon testing and commissioning 6
core OFC cable with splicing etc as required in
14 existing HDPE pipe. MR - Meter 168.15 -
Supply installation testing and commissioning of
15 fully loaded 12 Port LIU. MR - Nos 17,487.60 -
Supply installation testing and commissioning of
16 3m SC-LC Patch cord. MR - Nos 2,073.85 -
Supply installation testing and commissioning of
17 SFP module. MR - Nos 14,535.00 -
Supply installation testing and commissioning of
18 3m Cat-6 patch cord. MR 41.00 Nos 952.85 39,066.85
Digitally signed by ARUN
Supplying and fixing of following sizes of medium
class PVC conduit along with accessories in
surface/recess including cutting the wall and
making good the same in case of recessed conduit
as required. 25mm Dia
Supplying and laying of following size DWC
HDPE pipe ISI marked along with all accessories
like socket, bend, couplers etc. conforming to IS
21 14930, Part II complete with fitting and cutting, 14.15.1 100.00 Meter 127.00 - 12,700.00 -
jointing etc. in the existing trench, complete as
63 mm dia (OD-63 mm & ID-51 mm nominal)
SITC of 5MP Outdoor Dome camera with
1/2.9‑inch CMOS, Effective pixels 3072 (H) x
1944 (V), 30fps, Sensitivity – (3100K, reflectivity
89%, 1/25, F1.3, 30IRE) Color 0.24 lx Mono 0.03
lx With IR 0.0 lx, 120 dB Dynamic range,
Electronic Day/Night, Automatic Electronic
Shutter (AES), H.265, H.264 MP (Main Profile);
M-JPEG Video compression, White balance,
Backlight Compensation, Privacy Mask,Rule
based alarms and tracking, Line crossing, Enter
/leave field, Follow route, Loitering, Idle /
22 removed object, People counting, Crowd density MR 37.00 47,642.50 17,62,772.50
estimation, 3D tracking based on Duration, Size,
Aspect ratio v/h, Speed, Direction, Color, Object
classes (Upright persons, Bikes, Cars, Trucks),
Audio detection (if microphone used), 4 to 10 mm
Automatic Varifocal (AVF) lens, MicroSD card
slot for edge recording, Motion, tamper and audio
detection, FTP, IR range upto 30mtrs Dropbox
and e-mail applications, 3 axis adjustment,
ONVIF Profile S & G & T, PoE, IP66 and
NEMA 4X, IK10, CE, FCC , UL certified. SD
card support up to 2TB.
SITC of 5MP IR Bullet camera with 1/2.9‑inch
CMOS, Total sensor pixels 2592 (H) x 1944 (V);
30 fps; Sensitivity – Measured according to IEC
62676 Part 5 (1/30, F1.6), Color 0.14 lx, Mono
0.032 lx, With IR 0.0 lx, 120dB WDR, H.265;
H.264; M- JPEG, Automatic Electronic Shutter
(AES); Intelligent Dynamic Noise Reduction,
Intelligent Defog,Rule based alarms and tracking,
Line crossing, Enter / leave field, Follow route,
Loitering, Idle / removed object, People counting,
23 Crowd density estimation, 3D tracking based on MR 4.00 41,325.00 1,65,300.00
Duration, Size, Aspect ratio v/h, Speed, Direction,
Color, Object classes (Upright persons, Bikes,
Cars, Trucks), Privacy Masking, Pixel counter,
Memory card slot, IR Range 30mtr, Automatic
Varifocal 3.2 to 10 mm, Alarm Input 1/1, Audio
Input/output, RJ45, G.711, Audio Streaming Full-
duplex / half duplex, ONVIF Profile S, G & T,
IP66, IK10, PoE, CE, FCC, UL certified. SD card
support up to 2TB. FTP, Dropbox and e-mail
SITC of 64 channel Network Video StoragE
NVR suitabe to access data from any remote
location including backup drive for 30days.
Digitally signed by ARUN
Detailed Estimate Based On DSR-2022 With Cost Index & Market Rate
Project - Proposed Composite Regional Centre (CRC) At Jamdoli, Agra Road, Jaipur (Rajasthan).
Name Of Work -Access Control System Work
Rate as per D.S.R. PAR 2023 MARKET BASED
Sr.No. Particulars Sch. No. Qty Unit per Amount(In Rs) Rate(Rs) Amount(Rs)
Supply, Installation, Testing and
Commissioning of 2 Reader Intelligent IP based
Controller with 32 bit processor, 10,000 card
holders, 1,00,000 transaction Logs Enclosure,
Power supply and with all accessories to finish
Supply, Installation, Testing and
2 Commissioning push botton door open switch MR 26 Each 12036.00 3,12,936.00
for single and double door.
Supply, Installation, Testing and
Commissioning IP based
3 Fingerprint Biometric Reader with built in MR 26 Each 33630.00 8,74,380.00
Smart card Reader, Power supply with wiegand
output fully networkable.
Supply, Installation, Testing and
5 Commissioning Single door Magnetic Lock with MR 13 Each 10148.00 1,31,924.00
Door Position Switch.
Supply, Installation, Testing and
6 Commissioning Double Door Magnetic Lock MR 13 Each 17405.00 2,26,265.00
with Door Position Switch
Supply, Installation, Testing and Commissiong
7 of Time Attendance software (PC based for MR 1 Each 88069.30 88,069.30
interfacing and programming) and with require
all accessories to finish the job
Supply, Installation, Testing and Commissiong
8 of Access Control Software (PC based for MR 1 Each 104081.90 1,04,081.90
interfacing and programming) and with require
all accessories to finish the job
SITC of PC Hardware with a minimum
speicification of Intel i7 Quad Core Processor
7th Generation at mim 3.6 GHz , Intel HD
Graphic, 8 GB or more of RAM, 500GB SATA
Hard Drive for OS and ACS & TA applications,
Network Interface Card - 10/100/1000 MB,
Dual Monitor Graphics card to support 2
multiplexed Monitors. DVD-R/W Microsoft®
Windows® 8.1 / 10 Pro or Higher 64 bit
Supply & Laying of 8core 1.0 sq. mm ATC PVC
10 insulated & sheated, twisted pair, Al shielded MR 1820 Meter 247.80 4,50,996.00
and overall FR PVC sheathed cable in in
existing 25 mm PVC/Steel Conduit.
Digitally signed by ARUN
Supply & Laying of 4core 1.5 sq. mm ATC PVC
11 insulated & sheated, twisted pair, shielded and MR 1820 Meter 141.60 2,57,712.00
overall FR PVC sheathed cable in existing 25
mm PVC/Steel Conduit.
Supplying and fixing of following sizes of steel
12 conduit along with accessories in surface/recess -
including painting in case of surface conduit, or
cutting the wall and making good the same in
case of recessed conduit as required.
Digitally signed by ARUN
Detailed Estimate Based On DSR-2022 With Cost Index & Market Rate
Project - Proposed Composite Regional Centre (CRC) At Jamdoli, Agra Road, Jaipur (Rajasthan).
Name Of Work - Lift Work
Rate derived as per PAR 2025 MARKET BASED
Sr.No. Particulars Sch.No. Qty Unit Amount(In Rs) Rate Amount(In Lac)
Supply Installation Testing and Commissioning of lift with power operated doors and AC
variable voltage and variable frequency controls having speed of minimum 1.5m/sec as per
1 CPWD specifications. 13 Passenger elevator with 3 stops 4.1
without machine room as per
13 Passenger (G+5)
Digitally signed by ARUN
Detailed Estimate Based On DSR-2022 With Cost Index & Market Rate
Project - Proposed Composite Regional Centre (CRC) At Jamdoli, Agra Road, Jaipur (Rajasthan).
Name Of Work -EPABX System Work
Rate as per D.S.R. 2022 MARKET BASED
Sr.No. Particulars Sch.No. Qty Unit Amount(In RS) Rate(Rs) Amount(In RS)
A EPABX SYSTEM
SITC of IP-PBX WITH REDUNDANT
CPU & REDUNDANT POWER SUPPLY
4 CO TRUNK, 50 ANALOG
EXTENSION, 10 SIP TRUNK, 4 E1 PRI
TRUNK, 10 IP EXTENSION, PMS
SITC of REDUNDANT FCBC WITH 12V
BATTERIES WITH 15AH CAPACITY
3 SITC OF IP PHONE WITH DISPLAY MR 10.00 Nos - 6,608.00 66,080.00
4 SITC OF BASIC PHONE WITH CLI MR 9.00 Nos - 1,888.00 16,992.00
S/f of I/O Boxes Krone connectors ,with
connection etc.
Wiring of Jelly Filled telephone Cable in
existing pipe for system with connection.
Supplying, installing, testing and
commissioning of 24 port CAT6 jack panel
loaded as per the connections required in
Supplying, installing, testing and
commissioning of 6 U wall mount rack
with fans , 2 cable managers , satationary
shelf , 2 Nos of hardware pkts.
Supplying, installing, testing and
9 commissioning of 24 10/100/1000BASE-T MR 1.00 Nos - 93,703.00 93,703.00
Supplying, installing, testing and
commissioning of 42 U wall mount rack
with fans , 2 cable managers , satationary
shelf , 2 Nos of hardware pkts.
Digitally signed by ARUN
SITC of 2m long Cat-6 patch cord as
Supplying and laying of following size
DWC HDPE pipe ISI marked along with
all accessories like socket, bend, couplers
conforming to IS 14930, Part II complete
with fitting and cutting,
jointing etc. in the existing trench,
complete as required. 100mm Dia
Digitally signed by ARUN
Detailed Estimate Based On DSR-2022 With Cost Index & Market Rate
Project - Proposed Composite Regional Centre (CRC) At Jamdoli, Agra Road, Jaipur (Rajasthan).
Name Of Work -Networking System Work
Rate as per D.S.R. 2022 MARKET BASED
Rate as Amount(In Amount(In
Sr.No. Particulars Sch.No. Qty Unit Rate
per DSR RS) RS)
A DATA / NETWORKING SYSTEM
S/F of Surface mount box with I/O Cat
1 6 and UTP jack D-Link complete in all MR 85.00 Nos - 548.70 46,639.50
2 S/I of Patch cord CAT6 UTP MR 85.00 Nos - 265.50 22,567.50
S/I/T/C of 24 port category 6e SL
Series patch Panel with active and
passive components,punching,
complete in all respect
S/I/T/C of 48 port category 6e SL
Series patch Panel with active and
passive components,punching,
complete in all respect
S/I/T/C of 24 port 10/100/1000 Base T
Standalone Gigabit Switch with active
and passive components, punching,
complete in all respect
S/I/T/C of 24 port 10/100/1000 Base T
Standalone Gigabit L2 Switch with
active and passive components,
punching, complete in all respect
Supplying, installing, testing and
commissioning of 6 U wall mount rack
7 with fans , 2 cable managers , MR 3.00 Nos - 13,118.00 39,354.00
satationary shelf , 2 Nos of hardware
Mapping of Network Nodes & LAN
SITC of WIFI Modem suitable to cover
atleast 25m distance having
9 compatibility to connect atleast 40-50 MR 37.00 Job - 77,408.00 28,64,096.00
devices without any distortion in signal
etc as required.
Digitally signed by ARUN
Detailed Estimate Based On DSR-2022 With Cost Index & Market Rate
Project - Proposed Composite Regional Centre (CRC) At Jamdoli, Agra Road, Jaipur (Rajasthan).
Name Of Work - Fire Fighting System Work
Rate as per D.S.R. 2022 MARKET BASED
Sr.No. Particulars Sch.No. Qty Unit DSR Rate(Rs) Amount (In Rs)
Sub Head : A (Pump Room)
Supplying, installation, testing and commissioning of Electric driven
Main Fire Pump suitable for automatic operation and consisting of
following, complete in all respects, as required :Horizontal type,
multistage, centrifugal, split casing pump of cast iron body & bronze
impeller with stainlesssteel shaft, mechanical seal conforming to IS
1520. Suitable HP Squirrel cage induction motor, TEFC,
synchronous speed 1500 RPM, suitable for operation on 415 volts, 3
phase 50 Hz, AC supply with IP 55 protection for enclosure,
horizontal foot mounted type with Class- 'F' insulation, conforming
to IS-325. supply , Installation, testing and commissioning of fire
Hydrant valve , bearing to IS:5290 marks, S.S. ,IS: 304 Grade,
63mm oblique instantaneous single out let, 75mm N.B. flanged inlet,
brass spindles complete with PVC blank cap . G.I. chain etc.
guard,foundation bolts etc.as required. supply , Installation, testing
and commissioning of Branch pipe . S.S. short type with 63mm male
instantaneous inlet, male threaded outlet fitted with 15mm, Bore
nozzle,having IS: 903 with anti vibration pads.
Supplying, installation, testing and commissioning of diesel engine
driven main fire pump suitable for automatic operation and
consisting of following,
complete in all respects, as required : (Diesel Driven Pump)
Horizontal type, multistage, centrifugal pump of cast of iron body
and bronze impeller with stainless steel shaft, mechanical seal
conforming to IS 1520. Suitable HP, 1500 RPM water cooled with
radiator, diesel engine conforming to relevant IS standard complete
with auto starting mechanism, 12 /24 volts electric starting
equipment, diesel tank, exhaust pipe extended upto 10 m outside
pump house duly insulated with 50 mm thick glass wool with 1.0 -
aluminium sheet cladding, residential silencer, instruments and
protection as per standard specification, stop solenoid for auto stop
in the event of fault with audio indications, painted with post office
red colour etc. as required.
M.S fabricated, common base plate, coupling, coupling guard,
foundation bolts etc. as required. Suitable cement concrete
foundation duly plastered
and with anti vibration pads.
Supplying, installation, testing and commissioning of electric driven
pressurisation pump suitable for automatic operation and consisting
of following, complete in all respects, as required : (Jockey Pump)
Horizontal type, multistage, centrifugal pump of cast iron body and
bronze impeller with stainless steel shaft, mechanical seal
conforming to IS : 1520. Suitable HP squirell cage induction motor
TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC -
supply with IP 55 class of protection for enclosure, horizontal foot
3 mounted type with Class-'F' insulation, conforming to IS : 325.
M.S.fabricated Common M.S.fabricated Common base plate,
coupling, coupling guard, foundation bolts etc. as required. Suitable
cement concrete foundation duly plasteredand with anti vibration
Digitally signed by ARUN
Fabrication, supply, Insallation testing & commissioning of
Electrical control panel of cubical construction, floor mounted type,
fabricated out of 2mm thick CRCA sheet, compartmentalised with
hinged lockable doors, dust and vermin proof, powder coated of
approved shade after 7 tank treatment process, cable alley,
interconnection with suitable size copper conductor cable/solid
4 copper strip, having switchgears and accessories, mountings and -
internal wiring, earth terminals, numbering etc. complete in all
respect, suitable for main fire pump, pressurisation pump & diesel
pump set complete as per CPWD specification with following in
coming and Outgoings, suitable for operation on 415V, 3 phase,
50Hz Ac Supply with.
400A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-
500V with selector switch Ammeter (0-400 A) with selector swtich
& CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip -
indicating lamps Set of Copper Bus Bar 500A
( Note : All outgoing feeders for pumps should have digital
Ammeter with selector switches, and LED type ON, OFF, trip -
indicating lamps)
Main Fire Pump -
160 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic
Star/Delta starter suitable for 75 hp pump with overload protection,
current sensing type single phase preventor complete with all
acceessories and internal wiring required for automatic operation, -
selector switch for local/remote, auto/manual/OFF operation.
100 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully
automatic Star/Delta starter with overload protection, current
sensing type single phase preventor complete with all acceessories -
and internal wiring required for automatic operation, selector switch
for local/remote, auto/manual/OFF operation.
Diesel Engine Control -
Control for diesel engine comprising - -
Automatic/Manual selctor switch & 3 attempt starting device, timers
and relays as required, push buttons, start/stop in manual mode
Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp
and Engine on indication Battery charger suitbale for 12V/24 V DC
with boost and trickle selector switch, 0-30 V DC volt meter, and 0-
20 A DC Ammeter All standard relays and accessories for automatic
operation of diesel engine System Controller Designing, Supply, 18.5.2 1.00 set 2,87,855.00 2,87,855.00 -
Installation, Testing and commissioning of system controller to
control operation of main electric fire pump, diesel pump,
Pressurization pump, Terrace pump in sequence as per specification
consisting of relays, timers. Sensors, annunciation window for fault
indication, complete as per specifications.
Supply, erection and testing of ISI marked M.S. pipes (class C) and
specials etc. (as per IS:1239) for above ground laying for hydrants
system includeing transportation of materials upto the worksite,
cuttings the pipes to required length, edge preparation, welding,
5 fixing / erection of pipes including specials i.e. bends, tees, reducers, 18.7 -
flanges expansion joints wherever required, washers, nuts, bolts etc.
in proper position including all supports as per layout.
200 mm dia (wall Thickness 6.3 mm)
Digitally signed by ARUN
Providing, installation, testing and commissioning of non-return
valve of following sizes confirming to IS: non-return valve of
6 following sizes confirming to IS: 5312 complete with rubber gasket, - -
GI bolts, nuts, 5312 complete with rubber gasket, GI bolts, nuts,
washers etc.as required washers etc.as required :
Providing, installation, testing and commissioning of stainless steel
7 Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, 18.15.4 - -
sheet with 3 mm dia holes with stainless steel flange.
Installing ,testing and commissioning of butterfly valve , PN-
8 1.0,slim seal,standard lever operated type with required flanges, nuts 18.11 - -
,bolts etc. complete.
Providing and fixining pressure gauge.
Providing and fixining 25 mm dia Ball Valve.
Providing and fixining air release valve.
Supplying & fixing air vessel made out of 250 mm dia,8 mm thick
MS sheet, 1200 mm in height with air release valve on top and
12 flanged connection to riser, drain arrangement with 25 mm dia gun 18.20 1.00 each 18,244.00 18,244.00 -
metal wheel valve with required accessories, pressure gauge and
painting with synthetic enamel paint of approved shade as required.
Supply, installation, testing & commissioning of flow switches with
two no and two NC contacts with necessary nipply & other fittings,
Flow switch shall be suitable for 150 dia.
Providing, fixing, testing & commissioning of installation control
valve of cast iron body, brass/bronze working parts comprising of
water motor alarm, bronze seat clapper, clapper arm and
hydraulically driven mechanical gong bell to sound continuous alarm
14 when the wet riser/sprinkler system activates, pressure gauges, 18.24.3 1.00 Each 48,202.00 48,202.00 -
emergency releases, strainer, pressure switch, cock valve complete
with drain valve and bypass, test control box, ball valves, MS pipe of
required size, flanges, orifice plate, gasket etc of follwing sizes as
Sub Head : B (External Hydrant)
Providing laying, testing & commissioning of 'C' class heavy duty
MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees,
flanges, tapers, nuts bolts, gaskets etc. in ground including welding,
1 excavation & providing cement concrete blocks as supports, 18.6 - -
anticorrosive treatment with coaltar/asphalt tape as per IS 10221,
refilling the trench etc. of following sizes complete as required.
Digitally signed by ARUN
Supplying, Installing, hydraulic testing and commissioning of heavy
grade MS Pipe confirming to IS:1239 part-1 with malleable specials
confirming to IS:1239 part-II, such as Tee, elbows, check nuts,
unions, flanges, nipple etc. Including cutting, fixing in/on wall/ on
Floors, ceiling by using usitable supports such as MS channels,
2 angles, flats, rods as required at site with anchor fastners, clamps, 18.7 - -
threaded rods, nuts, bolts, washers etc.. complete. Painting the
exposed with one coadt of metal zinc chromate primer with two
coats of synthetic enamal paint of approved colour/shade etc.
Supplying and fixing Single headed external yard hydrant valve with
1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel
coupling and cast iron wheel, ISI marked, conforming to IS 5290
(type A) with blank Gunmetal/Stainless Steel cap and chain as
Supplying and fixing orifice plate made out of 6 mm thick stainless
steel (Grade 304) with orifice of required size to be fitted between
4 flange & landing valve of 18.13 13.00 each 1,321.00 17,173.00 -
external and internal hydrants to reduce pressure at the outlet to the
level of 3.5 kg/cm2 complete as required.
Hose cabinet stand mounted type fabricated out of M.S. sheet of 16
swg. With glass fronted (4mm thick glass with rubber beading) door
and size of the cabinet shall be 600x750x250mm Quoted rate shall
5 be inlcludes suitable stand for mounting for ground level with MR 13.00 each - 7,670.00 99,710.00
sup[orts all fastners etc, and cabinet shall be painted/powder coated
of approved colour both inside and out side.
supply , Installation, testing and commissioning of Branch pipe . S.S.
6 short type with 63mm male instantaneous inlet, male threaded outlet 18.18.2 13.00 EACH 1,662.00 21,606.00 -
fitted with 15mm, Bore nozzle,having IS: 903.
supply , Installation, testing and commissioning of Fire Hose,RRL
hose jacketed with circular woven synthetic fibre,conforming to IS
636:88 63MM DIA.x 15mt. Long with SS 63mm 2 pair of male and
7 female instantaneous coupling having IS :903 mark and duly S.S. 18.16.1 26.00 EACH 5,202.00 1,35,252.00 -
wire wounded. The hose shall be rolled and hug to suitable M.S.
support in the fire station.
Sub Head : C (Internal Hydrant)
Supply, erection and testing of ISI marked M.S. pipes (class C) and
specials etc. (as per IS:1239) for above ground laying for hydrants
system includeing transportation of materials upto the worksite,
cuttings the pipes to required length, edge preparation, welding,
1 fixing / erection of pipes including specials i.e. bends, tees, reducers, 18.7 - -
flanges expansion joints wherever required, washers, nuts, bolts etc.
in proper position including all supports as per layout.
Supply , Installation, testing and commissioning of Fire Hydrant
valve , bearing to IS:5290 marks, S.S. ,IS: 304 Grade, 63mm
2 oblique instantaneous single out let, 75mm N.B. flanged inlet, brass 18.9.1 6.00 EACH 7,646.00 45,876.00 -
spindles complete with PVC blank cap . G.I. chain etc.
Digitally signed by ARUN
supply , Installation, testing and commissioning of Branch pipe . S.S.
short type with 63mm male instantaneous inlet, male threaded outlet
fitted with 15mm, Bore nozzle,having IS: 903
supply , Installation, testing and commissioning of Fire Hose,RRL
hose jacketed with circular woven synthetic fibre,conforming to IS
636:88 63MM DIA.x 15mt. Long with SS 63mm 2 pair of male and
4 female instantaneous coupling having IS :903 mark and duly S.S. 18.16.1 12.00 EACH 5,202.00 62,424.00 -
wire wounded. The hose shall be rolled and hug to suitable M.S.
support in the fire station.
supply , Installation, testing and commissioning of manual swing
type Fire hose reel IS:884 comp. with heavy duty reel, 19mm dia. X
30 mtr. Long 2- ply polyster yarn braided / rubber braided pressure
hose with heavy duty nylon on/off jet/ spray nozzle, 25mm isolating
valve and all other necessory.
Supply and fixing of Fire Shaft door fabricated out of G.I. Sheet and
frame, door shall be 900mm x 1500mm min with double leaf. &
fixed with 4 mm thick Glass, suitable Rubber beeding and Locking
6 arrangment. Quoted rate shall be included alll fasterners etc, and MR 6.00 EACH - 5,900.00 35,400.00
complete shutter shall be powder coated of approved colour both
inside and out side.
7 Providing/Fixing Fire man axe. Make. MR 6.00 Each - 472.00 2,832.00
CO2 type Fire exitinguisher ISI marked confirming to IS:15683
lates. Capacity 4.5 kg complete with delivery hose horn, squeeze
grip release valve, locking arrangement, operating temperature -30°c
to +55°c, supplied with body bearing IS 7285 mark and approved
8 valve as per IS 3224. Co2 Gas as per IS:15222. externally painted - -
with PO Red Shade No. 538 of IS 5, operation manual and floor
stand or wall mount Bracket including accessories as required as per
site condition.
Powder Fire exitinguisher (stored Pressure Type) (Powder
pressurized with dry nitrogen gas at 15 bar) capacity 4kg duly ISI
marked conforming to IS:15683:2006/latest, with IS 14609 ISI
marked ABC powder complete with squeeze grip release valve,
9 discharge pipe, locking arrangment, pressure gauge, operation - -
maual, Body Hydrotested at 35 bar, operating temperature--30°c to
+55°c, external epoxy powder coating with PO Red shade No. 538
of IS 5, and floor stand or wall mount Bracket including accessories
as required as per site condition.
Sub Head : D (SPRINKLER SYSTEM )
Supplying, Installing, hydraulic testing and commissioning of heavy
grade MS Pipe confirming to IS:1239 part-1 with malleable specials
confirming to IS:1239 part-II, such as Tee, elbows, check nuts,
unions, flanges, nipple etc. Including cutting, fixing in/on wall/ on
Floors, ceiling by using usitable supports such as MS channels,
1 angles, flats, rods as required at site with anchor fastners, clamps, 18.7 - -
threaded rods, nuts, bolts, washers etc.. complete. Painting the
exposed with one coadt of metal zinc chromate primer with two
coats of synthetic enamal paint of approved colour/shade etc.
Digitally signed by ARUN
Supply testing and commissioning of 15mm gunmetal/chrome
quartzoid bulb, standard reponse sprinkler heads suitable for 65 deg.
Horizontal side wall sprinkler 18.21.3 4.00 Each 617.00 2,468.00 -
Dial Type pressure guage for (0-16 kg/cm2) with necessary nipple &
3 other fittings, mounting arrangements and with 15 mm ball valve. MR 6.00 Each - 3,009.00 18,054.00
Supply, Installtion, Testing & commissioning of 25mm ball valve
4 with sight glass for sprinkler test line. MR 6.00 Each - 1,770.00 10,620.00
Supply, Installation, testing & commissioning of 50mm ball valve
5 for sprinler drain line. MR 6.00 Each - 2,714.00 16,284.00
Supply, installation, testing & commissioning of flow switches with
two no and two NC contacts with necessary nipply & other fittings,
Flow switch shall be suitable for 100 dia.
Installing ,testing and commissioning of butterfly valve , PN-
1.0,slim seal,standard lever operated type with required flanges, nuts
,bolts etc. complete.
Supply & Fixing of approved type rosette plates (Recessed Type, in
two piece) for sprinklers below false ceiling area. Rosette shall be
S.S. 304 as approved by engineers/ services consultants.
Stainless steel corrugatd flexible pipe(hose) for dropping sprinklers
below false ceiling, pipe shall be UL Listed, 16 bar pressure rating
9 and 25 mm dia with union/reducers collor, clamps etc. as 18.25 - -
required.(Braided)
Supply, Installtion, testing and commissioning of 25 mm diameter
10 Forged Brass air release valve PN-1.6 Body. MR 2.00 Each - 1,475.00 2,950.00
Supply, Installation and commissioning of Annunciator Panel with 7
11 windows with point, zone & system status used with RS 485. MR 1.00 Each - 89,208.00 89,208.00
12 Supply, Installation wire for annunciator panel. - -
Digitally signed by ARUN
Detailed Estimate Based On DSR-2022 With Cost Index & Market Rate
Project - Proposed Composite Regional Centre (CRC) At Jamdoli, Agra Road, Jaipur (Rajasthan).
Name Of Work -Fire Detection Alarm & PA System Work
Rate as per D.S.R. 2022 MARKET BASED
Rate as per Amount (In Amount (In
Sr.No. Particulars Sch.No. Qty Unit Rate
DSR Lac) Lac)
Fire Alarm System :
Supplying, installation, testing and commissioning of
micro processor based intelligent addressable main fire
alarm panel, central processing unit with the following
loop modules and capable of supporting not less than 240
devices (including detectors) and minimum 120 detectors
per loop and loop length up to 2 km, network
communication card, minimum 320 character graphics/
LCD display with touch screen or other keypad and
minimum 4000 events history log in the non volatile
1 memory (EPROM), power supply unit (230 ± 5% V, 50 17.2.1
hz), 48 hrs back-up with 24 volt sealed maintenance free
batteries with automatic charger. The panel shall have
facility to connect printer to printout log and facility to
have seamless integration with analog/digital voice
evacuation system (which is part of the schedule of work
under SH: PA System) and shall be complete with all
accessories . The panel shall be compatible for IBMS
system with open protocol BACnet/ Modbus over IP
complete as per specifications.
Supplying, installation, testing & commissioning of
central graphical fire alarm management system to
centrally monitor and operate the fire alarm system
complete as required.
Supplying, installation, testing & commissioning of
repeater panel wih 320 character/ Touch screen LCD
display with inbuilt reset, acknowledge and silence
switches complete as required.
Supplying, installation, testing & commissioning of
intelligent analog addressable photothermal (Smoke)
detector complete with mounting base complete as
Supplying, installation, testing & commissioning of
response indicator on surface/recessed MS Box having
two LED, metallic cover complete with all connections
etc as required.
Supplying, installation, testing & commissioning of fault
isolator complete with base as required.
Supplying, installation, testing & commissioning of
intelligent addressable thermal detector with rate of rise
cum fixed tempreature thermistor complete with base as
Supplying, installation, testing & commissioning of
addressable fire control module complete as required.
Digitally signed by ARUN
Supplying, installation, testing & commissioning of
addressable phone control module complete as required.
Supplying, installation, testing & commissioning of
addressable beam detector with short circuit isolator
or seperate) complete with emitter and receiver including
connections with remote test features etc complete as
Supplying, installation, testing & commissioning of
addressable manual call point complete as required.
Supplying, installation, testing & commissioning of
addressable horn cum strobe complete as required.
Supplying, installation, testing & commissioning of fire
fighter telephone handset complete as required.
Supplying, installation, testing & commissioning of fire
fighter phone jack complete as required.
Supplying & laying of 2x1.5 sqmm fire survival
armoured cable, 600/1000V rated with annealed copper
conductor having glass mica fire barrier tape covered by
15 an extruded layer of Cross Linkable Ethylene Propylene 17.5.1 1850 metre 359.00 6,64,150.00 -
Rubber (EPR) insulation and LSZH inner bedding, steel
wire armouring & LSZH outer sheath complete as
Public Addressable System : - -
Supplying, installation, testing & commissioning of 6
zone, voice alarm controller with USB, MP3 player
16 (including 6 zone button paging station) with seamless 17.3.1 1 each 1,26,411.00 1,26,411.00 -
integration facility with main fire alarm panel for voice
evacuation complete as required.
Supplying, installation, testing & commissioning of
1.5/3/6W ceiling speaker complete as required.
Supplying, installation, testing & commissioning of
18 1.5/3/6W metal box ceiling/wall speakers complete as 17.3.3 6 NOS 1,793.00 10,758.00 -
Supplying, installation, testing & commissioning of
19 digital audio amplifier 500 Watt, 25V rms operating at MR 1 each - 2,78,008.00 2,78,008.00
240 Volt AC Supply complete as required.
Supplying, installation, testing & commissioning of
20 Voice command keypad 6 zone, with microphone 17.3.9 1 each 81,756.00 81,756.00 -
assembly complete as required.
Digitally signed by ARUN
Supplying and drawing of cable Fire Retardant PVC
insulated copper conductor cable in the existing surface /
21 recessed steel conduit of following pairs, cores and size 17.5.3 - -
connections and interconnections etc. as required.
17.5.3.1 speaker cable Single pair, 2-core, 1.5 sqmm 17.5.3.1 1640 metre 54.00 88,560.00 -
Same as in item 148, but 25mm dia PVC conduit.
Digitally signed by ARUN
NAME OF WORK -PROPOSED CONTRACTION OF COMPOSITE REGIONAL CENTRE (CRC) AT JAMDOLI, AGRA ROAD , JAIPUR (RAJASTHAN)
PROJECT : COMPOSITE REGIONAL CENTRE (CRC) AT JAMDOLI, AGRA ROAD , JAIPUR (RAJASTHAN)
DSR 2025 AS PER MARKET RATE
DSR - RATE AMOUNT
Sr.No. Description Qty Unit QTY AMOUNT RATE (RS.)
VRV/VRF Out Door units :
Supply, Installation, Testing & Commissioning of Modular type Variable
Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units
suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s),
minimum two compressors (with individual seperate PCB) for above 14HP modules, icroprocessor based
Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators
with suitable foundation etc. complete as required. To have better efficiency condensor fan shall be capable to
operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as
per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping.
The system shall be able to deliver 100% of the rated capacity upto 39 Degree Celcius. The unit shall be
suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be
filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a
hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion,
and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal
Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building
Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as
required. (For capacity <40 kWr ISEER 6.4, Capacity >40 and <70 ISEER 6.5, Capacity > 70 ISEER 6.6 for
ECSBC+ Building) For Cooling or Heating or Both
Supply, Installation, Testing and Commissioning of following minimum
capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter,
fan section with low noise fan /dynamically balanced blower, multispeed motor, coil section with DX Copper
coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation,
Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete,
as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Signals. The
system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of
indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature
Wall Monuted Type units:
Supply, Installation, Testing and Commissioning of following minimum
capacity High wall type Indoor unit equipped with and comfort washable
synthetic media pre-filter, fan section with low noise fan/dynamically
balanced blower, multispeed motor, coil section with DX copper coil,
electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc.,
suitable for operation on 230 V ± 10%, 50Hz, single phase AC supply, complete as required. The Indoor units
must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to
adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet
conditions of 27 Degree C DB and 19 Degree C WB temperature.
Supply, Installation, Testing and Commissioning of Y/T/Multi Joints. Joints shall be of same Original Nos.
4 7.13 Equipment Manufacturer (OEM) make as of ODUs and IDUs
4.2 7.13.2 Outdoor Units Multi Joint Nos. Nos. 8 8,098.00 64,784.00
Supply,Installation,testing and commissioning of corded Cord type remote control with thermostat, LED
5 MR Display and internal wiring for Cassette & hi-wall . Nos. 63 3,038.50 1,91,425.50
6 7.14 COPPER REFRIGERANT PIPING
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following
nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with
suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE
Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of
specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as
6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
6.3 7.14.3 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm 700 Rmt 155 487.00 75,485.00
6.4 7.14.4 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm 500 Rmt 425 615.00 2,61,375.00
6.5 7.14.5 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm 550 Rmt 80 739.00 59,120.00
6.6 7.14.6 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm 650 Rmt 95 904.00 85,880.00
6.7 7.14.8 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm 550 Rmt 110 1,157.00 1,27,270.00
6.8 7.14.10. 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm 190 Rmt 105 1,286.00 1,35,030.00
6.9 7.14.12 41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm 550 Rmt 98 1,368.00 1,34,064.00
Digitally signed by ARUN
Supply installation testing commissioning Shielded Control Cables for VRV System with necessary ISI mark
Medium class rigid PVC pipes with necessary accessories with termination in machine and control equipments.
7.1 (A) 2Cx1.5 Sq mm Shielded Armoured(for communication lead & remote ) Rmt 1485 223.26 3,31,535.16
Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to be erected as
8 MR directed of following size.
3C x 2.5 sq.mm FOR INDOOR UNIT POWER CABLE
9 MR Drain Piping :
Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation.
VENTILATION SYSTEM
Supply, installation, testing and commissioning of floor mounted / ceiling hang Axial flow type supply air fan
for Lift well, lobby & stairwell pressurization of following capacity with powder coated GSS/M.S. casing and
aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC
induction motor (efficiency 1) and 'F' class insulation suitable for 3 Phase, 50 Hz, 415±10% Volt, TP isolator
with M.S enclosure box complete as required and as per specifications. Fans should be statically &
dynamically balanced.The fan static pressure shall be 20 mm WC static. as per site condition
a) 3500 CFM (for Lift)
c) 10000 CFM ( Smoke Exhaust)
Supply, installation, testing & commissioning of ducted Inline Fans constructed of GSS duly powder coated
(rectangualr box type & circular type) with centrifugal blower and motor encased in sheet metal casing, canvas
connection etc.The Fan motor shall have electric motor suitable for operation on 220 V+ 10%,50 Hz, 1 phase
AC supply. The Fan assembly shall conform to specifications & in accordance with requirements of drawings
& Schedule Of Quantities.
Supplying, installation, testing & commissioning of Propeller type exhaust air fans suitable for following
capacities complete with electric motor suitable for operation on 220 V+ 10%,50 Hz, 1 phase AC supply
fitted with speed regulator, mountings, frames, louvers and bird screen etc. of the following capacities.
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round
ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per
13 approved drawings and specifications of following sheet thickness complete as required.
16.12.2. Thickness 0.63 mm sheet 600
Supplying & fixing of powder coated extruded aluminium Supply Air Grills/fresh Grill with aluminium
volume control dampers complete as per specifications and size & shape as per site requirement and approved
Supplying & fixing of powder coated extruded aluminium Return Air /Exhaust Grills with louvers but
15 16.16 without volume control dampers complete as per specifications and size & shape as per site requirement and Sqm 6 5,181.94 31,091.63
approved design.
Supply,installation,testing and commissioning of flexible duct connections constructed of fire resistance
16 MR flexible double canvas sleeve as per the drawings and specifications. Sqm 20 7,637.55 1,52,751.00
Supply, installation, testing and commissioning of anodised aluminium Fresh air/exhaust air louvers with bird
17 MR screen as per specifications and drawings. Sqm Sqm 2 9,950.94 19,901.88
Fully automatic DOL starter suitable for operating 3.7kw motors/fan capacity, complete with contactors,Timer,
overload protection relay, current sensing type single phase preventer, ON indications, push buttons, auto /
18 MR manual / off selector switch,other accessories. complete as required. Set 6 35,849.58 2,15,097.48
Digitally signed by ARUN
SUMMARY OF RATES-AUDIO VISUAL
S.No. Description of Area Qty Amount Total Amount
S.No. Description of Area Qty Amount Total Amount
1 1st Floor Classrooms 8.00 41,370.80 3,30,966.40
5 2nd Floor Classrooms 4.00 41,370.80 1,65,483.20
Digitally signed by ARUN
S.No Description Qty Unit Rate Amount
1 Supply,Installation,Testing & 1 Nos. 2,950.00 2,950.00
Commissioning of Wall Hardware for the
2 Supply,Installation,Testing & 4 RM 3,115.20 12,460.80
Commissioning of High Speed triple-
shielded bonded pairs HDMI Cable with
Ethernet Gold Palted Lockable
Connector. It support Data Transfer rate of
upto minimum 10GBps and upto 48 bit
Deep Color. Cable has overall shield
against EMI/RFI interference and CL2
flame tested , Length 1.8mtr.
3 Supply,Installation,Testing & 100 RM 141.60 14,160.00
Commissioning of CAT6A U/FTP 4
shielded twisted pairs ,23AWG solid
copper conductor Video & LAN , Bulk
Cable — Low Smoke & Halogen Free
recommended by HDBaseT. .
4 Mis Interface Cables & Connectors 1 Set 11,800.00 11,800.00
Total 41,370.80
Digitally signed by ARUN
MULTIPURPOSE HALL(12000X23770)
S.NO Description Qty Unit Rate Amount
1 Supply of All In One Active LED of 165" Diagonal, No. 1 32,41,703.08 32,41,703.08
overall size 3,674*2,175*31,Pixel pitch 1.9mm ,
Resolution 1920 x 1080 , Aspect Ratio 16:9 , Pixel
Density per sqm - 275,290, Cabinet Material
Magnalium, Screen Protection Coating On
Surface,Brightness(Typical) 800 Nits , Refresh
Rate (Hz) 3840, Contrast ratio 10,000:1 , Inbuilt
Wireless presenter , In built speakers , Inputs 3 x
HDMI , Output 1 x HDMI , Embedded controller ,
Signal processing Upto 4 simultaneous source
display, Controller android, Storage 32 GB ,1 x
RS 232 port , 1 x 485 port , 1 x LAN port complete
with IR Remote control with wall mount hardware.
2 Supply, installation, testing & commissioning of No. 3 150527.88 4,51,583.64
PTZ ,Camera with HD Resolution Real High
Definition Image with 1/2.3 inch or higher high
quality HD CMOS sensor , 1920 x 1080 super
high quality video ,20 x or more zoom with 20x or
more digital zoom, Pan Range: 170deg or more
With HDMI output interface for video & RS 232/
RS 422 for controls 10 or more preset position.
3 Supply , Installation , Testing & Commissioning of No. 1 160480 1,60,480.00
Matrix 4k Switcher Metal Chassis , with 6 nos
Input slots (HDMI/DVI /DisplayPort/HdBaseT ) , 2
nos. output , Resolution 4k (4096x2160 ) ,
Input/Output Signal Types HDMI/DVI
/DisplayPort/HdBaseT,Advanced EDID
management,HDCP complaint , Audio output ,
Ethernet port 10/100 Mbps.
4 Supply , Installation , Testing & Commissioning No. 4 53100 2,12,400.00
Twisted pair transmitter convert HDMI to Cat6 signal
( Upto 70 meter ), Resolution upto WUXGA ,
HDCP2.2 complaint , compatability with CEC and
EDID signals , Audio compatability , audio formats
including Dolby TrueHD, Dolby Digital Plus, and DTS-
HD Master Audio transmission.
Digitally signed by ARUN
5 Supply , Installation , Testing & Commissioning No. 4 78068.8 3,12,275.20
Twisted pair receiver convert Cat6 signal to HDMI ,
Resolution WUXGA HDCP2.2 complaint ,
compatability with CEC and EDID signals , Audio
compatability , audio formats including Dolby
TrueHD, Dolby Digital Plus, and DTS-HD Master
Audio transmission.
6 Supply , Installation , Testing & Commissioning of No. 16 9385.72 1,50,171.52
Ceiling Speakers with 30 Watts Continuous Power
Handling, requency Range (-10 dB): 80 Hz - 20 kHz ,
Frequency Response (+/- 3 dB): 100 Hz - 18 kHz ,
Power Capacity1: 150 W , Sensitivity2: 87 dB SPL, 1
W 1 m (3.3 ft) , Maximum SPL3: 108 dB continuous,
Supply , Installation , Testing & Commissioning of No. 2 69502 1,39,004.00
Dual Channel Amplifier with utput 240W @ 4/8 Ohms
(1kHz Power, THD+N<0.5%) , Frequency Response
+/- 1dB (@1W into 4 or 8 Ohms) Load Impedance
Stable from 2 - 16 Ohms Sensitivity 1.4Vrms , Signal
to Noise Ratio -weighted , Input Impedance Balanced
20K Ohms/Unbalanced 10K Ohms , Max Input
+20dBu Typical.
Supply,Installation,Testing & Commissioning of Digital No. 3 27140 81,420.00
Wireless handheld microphone system, 200 selectable
frequencies, RF Carrier Frequency Range -
CH1: 612.000 - 651.600 MHz (100 Selectable
Frequencies) CH2: 652.000 - 691.600 MHz (100
Selectable Frequencies), Audio Frequency
Range - 30Hz ~ 20 kHz, Signal-to-noise (A-weighted) -
120dB(A) , RF output - 50 mW max, Oscillation Mode -
Inside the chip VCO oscillation .
9 Supply,Installation,Testing & Commissioning of No. 4 3115.2 12,460.80
High Speed triple-shielded bonded pairs HDMI
Cable with Ethernet Gold Palted Lockable
Connector. It support Data Transfer rate of upto
minimum 10GBps and upto 48 bit Deep Color.
Cable has overall shield against EMI/RFI
interference and CL2 flame tested , Length
Supply,Installation,Testing & Commissioning of RM 100 141.6 14,160.00
Speaker Cable fof 2 Core 1.5 Sq. mm.,
stranded copper wire for maximum flexibility
and covered with a tough PVC jacket to
help prevent chafing,Wire should be
designed to maximize sound quality and for
better frequency response Cable with thickness
of 2 Core1.5 Sq. mm. .
Digitally signed by ARUN
Supply,Installation,Testing & Commissioning of RM 150 127.44 19,116.00
CAT6A U/FTP 4 shielded twisted pairs ,23AWG
solid copper conductor Video & LAN , Bulk Cable
— Low Smoke & Halogen Free recommended by
Supply,Installation,Testing & Commissioning of No. 1 45312 45,312.00
Equipment Rack , Size 24u u with front glass door
, rear vented MS door , Lockable both doors ,
Inbuilt fitted Blower & Castors with power
distribution panel.
Mis Interface Cables & Connectors Set 1 21240 21,240.00
Digitally signed by ARUN
Director's Room
S.No Description Qty Unit Rate Amount
1 Supply,Installation,Testing & Commissioning of Wall Hardware for the 1 Nos. 2,950.00 2,950.00
2 Supply,Installation,Testing & Commissioning of Wireless 1 Nos. 1,47,500.00 1,47,500.00
Presentation system with Operating system Windows 10 and higher
macOS 11 (BigSur) and higher , Android v9 and higher , iOS 12 and
higher (App) ; Video outputs 4K UHD (3840*2160) 30Hz. HDMI 1.4b
or USB-C DisplayPort 1.2 , Audio output HDMI, USB 1 X USB-A, 1 X
USB-C , Buttons 2nos ; Airplay, Google Cast, Miracast ; Maximum
number of simultaneous connections 32 ; Noise Level Max. 25dBA 0-
30°C , Max. 30dBA 30-40°C ; Authentication protocol WPA2-PSK in
stand alone mode , WPA2-PSK or IEEE 802.1X ; Wireless
transmission protocol IEEE 802.11 a/g/n/ac and IEEE 802.15.1.
3 Supply,Installation,Testing & Commissioning of High Speed triple- 4 RM 2,596.00 10,384.00
shielded bonded pairs HDMI Cable with Ethernet Gold Palted
Lockable Connector. It support Data Transfer rate of upto minimum
10GBps and upto 48 bit Deep Color. Cable has overall shield
against EMI/RFI interference and CL2 flame tested , Length
4 Supply,Installation,Testing & Commissioning of CAT6A U/FTP 4 100 RM 106.20 10,620.00
shielded twisted pairs ,23AWG solid copper conductor Video & LAN ,
Bulk Cable — Low Smoke & Halogen Free recommended by
5 Mis Interface Cables & Connectors 1 Nos. 14,160.00 14,160.00
Grand Total 1,85,614.00
Grand Total 1,85,614.00
Digitally signed by ARUN
CONFERENCE ROOM - Seating Capacity 40
S.No Description Qty Unit Rate Amount
1 Supply,Installation,Testing & Commissioning of Wall Hardware 1 Nos. 2,950.00 2,950.00
for the Display panel.
2 Supply , Installation , Testing & Commissioning of Matrix 4k No. 1 160480 1,60,480.00
Switcher Metal Chassis , with 6 nos Input slots (HDMI/DVI
/DisplayPort/HdBaseT ) , 2 nos. output , Resolution 4k
(4096x2160 ) , Input/Output Signal Types HDMI/DVI
/DisplayPort/HdBaseT,Advanced EDID management,HDCP
complaint , Audio output , Ethernet port 10/100 Mbps.
3 Supply, installation, testing & commissioning of PTZ ,Camera No. 1 150527.88 1,50,527.88
with HD Resolution Real High Definition Image with 1/2.3 inch
or higher high quality HD CMOS sensor , 1920 x 1080 super
high quality video ,20 x or more zoom with 20x or more digital
zoom, Pan Range: 170deg or more With HDMI output
interface for video & RS 232/ RS 422 for controls 10 or more
preset position.
4 Supply , Installation , Testing & Commissioning of Dual Channel 1 Nos. 69,502.00 69,502.00
Amplifier with utput 240W @ 4/8 Ohms (1kHz Power, THD+N<0.5%)
, Frequency Response +/- 1dB (@1W into 4 or 8 Ohms) Load
Impedance Stable from 2 - 16 Ohms Sensitivity 1.4Vrms , Signal to
Noise Ratio -weighted , Input Impedance Balanced 20K
Ohms/Unbalanced 10K Ohms , Max Input +20dBu Typical.
5 Supply , Installation , Testing & Commissioning of Ceiling Speakers No. 8 9385.72 75,085.76
with 30 Watts Continuous Power Handling, requency Range (-10 dB):
80 Hz - 20 kHz , Frequency Response (+/- 3 dB): 100 Hz - 18 kHz ,
Power Capacity1: 150 W , Sensitivity2: 87 dB SPL, 1 W 1 m (3.3 ft) ,
Maximum SPL3: 108 dB continuous, 114 dB peak.
6 Supply,Installation,Testing & Commissioning of Wireless 1 Nos. 1,47,500.00 1,47,500.00
Presentation system with Operating system Windows 10 and
higher macOS 11 (BigSur) and higher , Android v9 and higher
, iOS 12 and higher (App) ; Video outputs 4K UHD
(3840*2160) 30Hz. HDMI 1.4b or USB-C DisplayPort 1.2 ,
Audio output HDMI, USB 1 X USB-A, 1 X USB-C , Buttons
2nos ; Airplay, Google Cast, Miracast ; Maximum number of
simultaneous connections 32 ; Noise Level Max. 25dBA 0-
30°C , Max. 30dBA 30-40°C ; Authentication protocol WPA2-
PSK in stand alone mode , WPA2-PSK or IEEE 802.1X ;
Wireless transmission protocol IEEE 802.11 a/g/n/ac and
7 Supply,Installation,Testing & Commissioning of Digital Wireless 2 Nos. 27,140.00 54,280.00
handheld microphone system, 200 selectable frequencies, RF
Carrier Frequency Range - CH1: 612.000 - 651.600 MHz
(100 Selectable Frequencies) CH2: 652.000 - 691.600 MHz (100
Selectable Frequencies), Audio Frequency Range - 30Hz ~ 20
kHz, Signal-to-noise (A-weighted) - 120dB(A) , RF output - 50 mW
max, Oscillation Mode -Inside the chip VCO oscillation .
8 Supply,Installation,Testing & Commissioning of High Speed 2 Nos. 2,596.00 5,192.00
triple-shielded bonded pairs HDMI Cable with Ethernet
Gold Palted Lockable Connector. It support Data Transfer rate
of upto minimum 10GBps and upto 48 bit Deep Color.
Cable has overall shield against EMI/RFI interference and
CL2 flame tested , Length 1.8mtr..
Digitally signed by ARUN
9 Supply,Installation,Testing & Commissioning of CAT6A 150 RM 106.20 15,930.00
U/FTP 4 shielded twisted pairs ,23AWG solid copper
conductor Video & LAN , Bulk Cable — Low Smoke &
Halogen Free recommended by HDBaseT.
10 Supply,Installation,Testing & Commissioning of Speaker RM 100 141.6 14,160.00
Cable fof 2 Core 1.5 Sq. mm., stranded copper wire for
maximum flexibility and covered with a tough PVC
jacket to help prevent chafing,Wire should be
designed to maximize sound quality and for better
frequency response Cable with thickness of 2 Core1.5 Sq.
11 Mis Interface Cables & Connectors Set 1 21240 21,240.00
Digitally signed by ARUN
S.No Description Qty Unit Rate Amount
1 Supply,Installation,Testing & Commissioning 1 Nos. 2,950.00 2,950.00
of Wall Hardware for the Display panel.
2 Supply,Installation,Testing & 4 RM 3,115.20 12,460.80
Commissioning of High Speed triple-
shielded bonded pairs HDMI Cable with
Ethernet Gold Palted Lockable Connector. It
support Data Transfer rate of upto minimum
10GBps and upto 48 bit Deep Color. Cable
has overall shield against EMI/RFI
interference and CL2 flame tested , Length
3 Supply,Installation,Testing & 100 RM 141.60 14,160.00
Commissioning of CAT6A U/FTP 4 shielded
twisted pairs ,23AWG solid copper conductor
Video & LAN , Bulk Cable — Low Smoke &
Halogen Free recommended by HDBaseT.
4 Mis Interface Cables & Connectors 1 Set 11,800.00 11,800.00
Total 41,370.80
Digitally signed by ARUN
Detailed Estimate Based On DSR-2022 With Cost Index & Market Rate
Project - Proposed Composite Regional Centre (CRC) At Jamdoli, Agra Road, Jaipur (Rajasthan).
Name Of Work -External Electrical Work
Rate as per D.S.R. 2025 (For Rate as per D.S.R. 2022 MARKET BASED
Sr.No. Particulars Sch. No. Qty Unit Amount(Rs) per Amount(Rs) Rate(Rs) Amount(Rs)
A Subhead-I HT Work
1 11 KV DOUBLE POLE STRUCTURE
Supply, erection, testing and commissioning of 2 pole structure for providing
1 No. 11KV,200A GOS in accordance with IE rules, & local authority MR 1.00 Set 2,14,760.00 2,14,760.00
specification and drawings and comprising of the following.
a. 2 Nos. 11 mtr. long MS STEEL poles complete with, pole excavation, MS
STEEL foundation, and back filling complete MS steel channel/angle iron etc.
b. 1 Set of cross arms, branching, clamps and painting complete with GI nut,
bolts & washers as required (for GO & DO), LA connection.
c .1 set 11KV Insulator complete with spindles & hardware complete as
d .1 No. 11KV 400A TP Gang operated Air break switches complete with
25mm dia GI pipe operating machanism, handle & locking arrangement.
e. 1 set of 3 nos.11KV single pole drop out fuse complete with barrel fuses,
and mounting arrangement.
f. 1 set (3 nos.) 11KV lightning arrestor and connecting to all phases. - -
g. 4 No. 150 mm dia 6 meter long GI pipe class 'B' (for XLPE cable
protection) as required.
h. 2 Set 50mm dia 3m long GI pipe earting with 25 x 6 mm GI earth strip
complete as required (for GO & DO & LA)
i 1 nos. 11KV HT danger boards and 2 set of anticlimbing devices. - -
11 KV Double Pole Structure described below - -
Supply of 3 core standered aluminium conductor XLPE (Cross linked
polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured
cables confirming to I.S. 7098 (Part-II with latest amendments) II KV grade
2 as per requirement. - -
Laying of one number PVC insulated and PVC sheathed / XLPE power cable
of 11 KV grade of following size direct in ground including excavation, sand
cushioning, protective covering and refilling the trench etc as required. DSR
Above 120 sq. mm and upto 400 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE
power cable of 11 KV grade of following size direct in ground in the same
trench in one tier horizontal formation including excavation, sand cushioning, DSR
4 protective covering and refilling the trench etc as required. 2022 - -
Digitally signed by ARUN
Above 120 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable
of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe DSR
5 as required. 2022 - -
Above 120 sq. mm and upto 400 sq. mm 8.3.2 150.00 Meter 134.00 20,100.00 - -
supplying and making indoor cable end termination with heat
shrinkable jointing kit complete with all accessories including lugs suitable for
following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as DSR
6 required : 2022 - -
Supplying and making outdoor cable end termination with heat shrinkable
jointing kit complete with all accessories including lugs suitable for following
size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : DSR
Supply and laying of 1800mm x 900mm x 12mm thick chequered rubbbber
8 matting of tested quality. MR 8.00 Each 3,452.60 27,620.78
Supply and fixing of shock treatment chart (prescribed under I.E. rules) duly
framed with glass and supported from back with hard board or soft board with
supply of all material labour T&P for proper completion of work.
Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked
IS : 2878 & TAC approved) complete with initial charge and wall bracket,
along with supply of all materials and labour for proper completion of work.
Supply and laying of PVC Insulated, FRLS Round Sheathed Multi Core
Industrial Flexible Cable conforming to IS 694:2010 with Flexible Bright
Annealed Copper Conductor for Voltage Grade 1100 Volts as per direction of
11 engineer incharge. - -
S.I.T.C. of VCB's Indoor Type as per latest specification of UP Power
Corporations, make prefered Cromptron,Schneider or any Equivalent make
approved by UP Power Corporation. Including construction of Plinth and
earthing etc. with all material as per Technical Requirment. with 05 years
12 warranty - -
Total For Subhead-I HT Work 2,08,774.00
B Subhead-II Transformer
1 TRANSFORMER - -
Digitally signed by ARUN
11/0.433 KV, 3 Phase, 50 Hz outdoor/ indoor mounting(Mineral oil
Supply, installation, testing and commissioning of following capacity
(continuous loading) BEE 3 Star rated (Corresponding Level as per BIS
amended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase,
50 Hz, Dyn 11 vector group, ONAN (Oil Natural Air Natural) copper wound
transformer (Electrolytic grade 99.9% pure copper, Core made of first grade
Cold Rolled Grain Oriented (CRGO) Core grade MOH or better, suitable for
out door/indoor applications with On Load Tap Changer (OLTC) on HV side
having AVR relay and Remote Tap Changer Control (RTCC) for automatic
sensing of incoming voltage, automatic operation of OLTC and facility for
remote and manual operation of OLTC HV side in range of +5% to-15% in
steps of 2.5%, having cable end boxes on HV side suitable for 3x300 sqmm -
XLPE cable of 11 KV grade, including bus trunking arrangement on LV side
including supplying and laying of copper conductor multicore control cable
from transformer to HT breaker/panel for safety tripping, complete with all
accessories and safety provisions as per relevant
IS Code including first filling of filtered dehydrated oil, i/c supplying and
grouting of suitable M.S. Channel with all accessories and transformer shall
be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 and duly ISI Marked
and as per CPWD specifications complete in all respects etc as required at
site. The maximum flux density in any part of the core and yoke at rated
voltage and frequency shall be such that the flux density with + 12.5 percent -
combined voltage and frequency variation from rated voltage and frequency
does not exceed 1.9 Tesla. The permissible temperature-rise shall not
exceed 35 dg.C for oil and 40 dg. C up to 200 KVA and 40 dg.C for oil and
dg. C for above 200 KVA for winding. Inside of tank shall be painted with
varnish or liquid resistant paint. For external surfaces one coat of thermo
setting powder paint or one coat of epoxy primer followed by two coats of
polyurethane base paint shallbe used. IS: 1180 (Part 3) shall be referred to
for paint thickness for normal to medium corrosive atmosphere. For highly
polluted atmosphere and special application external paint work shall be as
per direction of Engineer-in-Charge. Design ambient condition : a) air
temperature 50 deg C, b) Relative Humidity 90 % Max, c) Seismic Zone as
per location of site, d) Altitude as per location/site. Noise level Shall not
exceed limits as per NEMA TR-1 with all accessories running measured as
per IEC 551 / NEMA standard. The transformer should have QR code which
should contain drawing, test report OEM manual,Geo- Tag of manufacturing
location etc. Marking Each transformer shall be provided with rating plate
made of anodized aluminum/ stainless steel material securely fixed on the
outer body, easily accessible,as per IS: 1180 Part-3. The entries on the rating
plate shall be indelibly marked. -
Digitally signed by ARUN
Fitting and Accessories : The following fittings shall be provided:- a) Two
earthing terminals with the earthing symbol b) Oil level gauge indicating oil
level at minimum, 30°C and maximum operating temperature; c) Air release
device (for non-sealed type transformers) d) Rating and terminal marking
plates; e) Silica gel breather f) Drain-cum-sampling valve (¾″ nominal size
thread, IS 554) preferably steel with plug for three phase transformers; g)
Thermometer pocket with cap; h) Oil filling holes having (1¼″ nominal size
thread) with cover (for sealed type transformers without conservator); i)
Lifting lugs for the complete transformer as well as for core and winding
assembly; j) Pressure relief device or explosion vent above 200 kVA; k) One
filter valve on the upper side of the tank (for transformers above 200 kVA); l) -
Unidirectional flat rollers (for transformers above 200 kVA); m) Inspection
hole (for transformers above 200 kVA); n) HV side neutral grounding strip
(where one of the HV bushing terminal is connected to earth);
o) Buchholz relay for transformers above 800 kVA. p) Arcing horns or
suitable rating lightning arrestors for HT side – 3 Nos. q) Bird guard; r) Oil
temperature indicator and winding temperature indicators for transformers
above 200 kVA with suitable tripping mechanism above permissible limit s)
Jacking pads (for transformer above 1 600 kVA); t) Additional Neutral
separately brought out on bushing for earthing. u) Magnetic oil level gauge
(for transformer above 1600 kVA) with low oil level alarm contact; v) Non
return valve (for conducting pressure test); w) Pressure relief device or
explosion vent x). Monogram Plate y) Inspection cover z). Detachable type DSR
radiators with top and bottom shutoff valve. aa) Oil Conservator with Oil
indicator, minimum level marking and drain plug for all transformers of
capacity 50 KVA and above. bb) Necessary hardware, clamps, lugs etc. for
termination on HV/MV etc. for all transformers.
Total For Subhead-II Transformer 6,73,755.00
C Subhead-III DG Set
Supply, installation, Testing & Commissioning of 'Silent Type Diesel
Generating set as per CPCB IV + or better norms along with having Prime
Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power
factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor,
including testing at factory and site with fuel, load for test and other
necessary arrangements Complete as per CPWD specifications, should
have QR code which should contain drawing, test report OEM manual,Geo-
Tag of manufacturing location, rating plate as per relevant IS Code etc. and DSR
consisting of the followings: 2025 - -
(A) Diesel Engine:
Turbocharged Diesel engine 4 stroke water cooled, multi cylinder,
dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM
suitable for above output of alternator at 40 Degree C, 50% RH & at 1000
Meter MSL , capable of taking 10% over loading for one hour after 12 hours
continuous operation. The engine will be with Electronic governor, Dry type
Air filter with service indicator, first filling of engine fuel (after
lubricating Oil, Coolant and other consumables complete with all the
required accessories, the Electronic governor shall be as per ISO 8528.The
engine shall comply to the latest CPCB norms (CPCB IV + or better) and
Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per
CPWD specifications.
(B) Engine mounted Instrument Panel fitted with and having digital display
Digitally signed by ARUN
(i) Start-stop switch with key
(ii) Water temperature indication
(iii) Lubrication oil pressure indication
(iv) Lubrication oil temperature indication
(v) Battery charging indication and Voltage indication
(vi) RPM indication
(vii) Over speed indication
(viii) Low lubricantion Oil trip indication
(ix) Engine Running Hours indication
(C) Alternator:
Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3
phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50%
RH & at 1000 Meter MSL. The alternator shall be having Screen Protected
Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically
balanced rotor, capable of taking 10% over loading for one hour after 12
hours of continuous operation, self cooled,self-excited and self-regulated
through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for
tropical conditions and with class- H insulation.
(D) Base Frame & Foundation:
Both the engine and alternator shall be mounted on suitable base frame
made of MS channel with necessary reinforcement which shall be installed
on suitable cement concrete foundation and vibration isolation arrangement
as per recommendations of manufacturer.
Daily service fuel tank of suitable liters capacity as per CPWD Specifications,
fabricated out of 3 mm thick M.S. sheet complete with all standard
accessories and fuel piping between fuel tank and diesel engine with MS
class 'C' pipes of suitable dia. Complete with valves, level indications &
accessories as required as per specifications.
(F) Exhaust System:
Dry exhaust manifold with hospital type exhaust silencer and catalytic
(G) Starting System:
12V/24V DC starting system comprising of starter motors: voltage
regulator and arrangement for initial excitation complete with suitable
numbers of batteries (180 AH capacity lead acid SMF type) as required as
per specifications. The battery shall be housed inside the acoustic enclosure
(H) Acoustic and weather proof enclosure with arrangement for fresh air
intake for cooling of the engine & alternator, extraction, discharging hot air in
to the atmosphere and the temperature rise inside the enclosure, noise level
outside enclosure. The acoustic enclosure should be suitable for cable
connection/connection through bus-trunking. Such arrangements on
acoustic enclosure should be water proof & dust-proof conforming to IP-65
protection. The enclosure shall be as per CPCB IV + or better norms etc. and
as per CPWD specifications.
Digitally signed by ARUN
Free standing floor mounted IP 42 automatic mains failure control panel
including auto by-pass, suitable for KVA as below for silent type DG set
complete with relays, timers, set of CTs for metering & protection and energy
analyser to indicate currents, phase and line voltages, frequency, power
factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase &
KW & provision for overload, short circuit, restricted earth fault, under
frequency, power (aluminum) and control (copper ) cabling of suitable size
upto 15 meter between AMF panel, LT Panel and DG Set including
connection interconnection etc. as required, all complete and inter locking
and communication/ Ethernet /RS485/SNMP port open protocol for BMS
integration including suitable software, the panel shall be of DG Set OEM
make etc. as per approved by Engineering in charge and including the
1. Suitable numbers and appropriate capacity 4 pole motorised
electrically operated draw out with cradle type 3 position ACB/ MCCB
with electronic release for O/C & E/F and shunt trip.
2. Auto/Manual/Test/Off selector switch
3. Protection for under and over voltage phase reversal (2 nos Over
voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage
4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15
VA class-I for metering
5. Energy analyser unit to indicate current, Voltage( L-N & L-L), kW, kVA
(Phase & Total), Frequency, KWH, PF.
6. LED Indicating lamps for load on mains and load on set.
7. Fuse/ MCB for instruments.
8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter
and ammeter, selector switch for trickle, off and boost and current
9. Main supply failure monitor.
10. Supply failure timer.
11. Restoration timer
12. Control unit with three impulse automatic engine start/stop and failure
to start lockout.
13. Impulse counter with locking and reset facility.
14. ON/OFF/Control circuit switch with indicator
15. Audio/Video annunciation for
(i) High water temperature
(ii) Low lubricating oil pressure
(iii) Engine over speed
(iv) Engine fails to start
(v) Full load/maximum load warning
16. Protection for over/under Frequency, Loss of AC sensing, Over
Current, Unbalancing load with suitable number of relays and
17. Maintenance notification based on Engine Run Hour & due date.
18. Load Management through PLC to achieve auto opening and closing of
incomer breakers, bus coupler switching of essential panel ,
interlocking providing signal to AMF Panel for load status and AMF
shall give command to DG Set to auto start / auto stop depending upon
load status and requirement etc. and necessary hardware and
software required to perform the operation shall be provided by the
160 KVA including all control wiring. 6.1.9 1.00 Each 11,87,133.00 11,87,133.00 -
Total For Subhead-III DG Set 11,87,133.00 - -
D Subhead-IV Distribution Panel
SITC of LT switchgear panels suitable for 433 V, 3 phase, 4 wire, 50 Hz
power distribution system. The panel shall be Indoor, free standing, floor
mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type
compartmentalised design fabricated out of 14 SWG CRCA sheet steel,
complete with colour coded, heat shrinkable PVC insulated, aluminium bus
bars and separate earth bus bar of adequate cross section through out the
length of the panel. The incoming and outgoing feeders shall be
accommodated in a fully segregated, modular multitier arrangement with - -
adequate size and distinct cable alley, bus bar alley/chamber. The panel shall
be complete with name plate, earthing, numbering, danger plate etc. as per
specifications and drawings as required. The panel shall withstand the fault
level of 50kA as per Single Line Diagram. The Panel shall also be capable to
communicate status like ON/OFF/ Trip through Modbus/Ethernet for major
component like ACB, MCCB, MCB & Multifunation meters.
Digitally signed by ARUN
The Main LT Panel shall use all draw out type breakers suitable for 415 V
AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Panel shall have
Buscoupler switching, auto operation of incommer and bus coupler, auto start
of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and
having following incomming and outgoing Air Circuit
Breakers,microprocessor release for overload, short circuit, instantaneous &
earthfault protection with Current & Voltage metering & LCD display. - -
Air Circuit Breaker with microprocessor release ge metering & LCD display ,
with ready to clsoe indicator, should have capability to communicate ON
/OFF/ Trip Status on Modbus/Ethernet and as per the detail specification of
ACB (Icu=Ics=Icw=65 KA (1 sec). MCCB, with microprocessor release
with LSIG protection functionand should not derate upto 50 decree
Centrigrate as per testing guideline as per IEC 60947-2 and all the ACB upto
2500Amp ACB should have same frame size LCD display for fault trip
history, haivng current limiting feature, double break mechanism & capability
to communicate ON /OFF/ Trip Status on Modbus/Ethernet. (65 KA Ics) - -
1 Nos. 800 Amp TPN EDO ACB 25KA LSIG having S/C, E/F O/C
protection, LCD Display having specs as per attached annexture From
800KVA Transformer having
R,Y,B Phase indication Lamp with control MCB
On, Off, Trip Status Indication with control MCB
Inbuilt Zone Slelective Interlocking function - -
Multifunction Meter
1 Nos. 320 Amp TPN EDO ACB 25KA LSIG having S/C, E/F O/C
protection, LCD Display having specs as per attached annexture From
200KVA Solar Power Backup having
R,Y,B Phase indication Lamp with control MCB
On, Off, Trip Status Indication with control MCB
Inbuilt Zone Slelective Interlocking function
Multifunction Meter - -
Reverse Power Relay
Power Conditioning Device
1 Nos. 125 Amp TPN EDO ACB 25KA LSIG having S/C, E/F O/C
protection, LCD Display having specs as per attached annexture From
200KVA Solar Power Backup having
R,Y,B Phase indication Lamp with control MCB
On, Off, Trip Status Indication with control MCB
Inbuilt Zone Slelective Interlocking function
Multifunction Meter - -
Reverse Power Relay
Power Conditioning Device
BUSCOUPLER - -
1 Nos. 320Amp TPN EDO ACB 25KA having specs as per attached
annexture having
R,Y,B Phase indication Lamp with control MCB
On, Off, Trip Status Indication with control MCB
1 Nos. 1000 Amp FP busbars of aluminium alloy as per SLD.
1 Nos. 400 Amp FP busbars of aluminium alloy as per SLD.
1 Nos. 400 Amp TP MDO MCCB 25 KA, having specs as per attached
annexture having
R,Y,B Phase indication Lamp with control MCB
On, Off, Trip Status Indication with control MCB - -
Digitally signed by ARUN
2 Nos. 500 Amp FP EDO MCCB 25 KA, having specs as per attached
annexture having
R,Y,B Phase indication Lamp with control MCB
On, Off, Trip Status Indication with control MCB
Officre L+P + FF + Spare
3 Nos. 315 Amp FP EDO MCCB 25 KA, having specs as per attached
annexture having
R,Y,B Phase indication Lamp with control MCB
On, Off, Trip Status Indication with control MCB - -
Officre L+P + FF + Spare
3 Nos. 160 Amp FP MCCB 25 KA
On, Off, Trip Status Indication with control MCB
Multifunction Meter
STP + PL + Spare
3 Nos. 100 Amp FP MCCB 25 KA
On, Off, Trip Status Indication with control MCB
Multifunction Meter - -
6 Nos. 63 Amp FP MCCB 25 KA
On, Off, Trip Status Indication with control MCB
Multifunction Meter - -
EX LIGHT + LIFT +Spare
Short Circuit Breaking capacity should not less than 25KA.
RELAYS AS PER SLD - -
200KVAR APFC PANEL TTA
Automatic Power Factor Correction (APFC) System
Supply, Installation, testing and commissioning of Automatic Power Factor
Correction (APFC) panel, indoor type floor mounted free standing totally
enclosed, extendable, IP 42, of following capacity for 3 phase, 415 V + 10 %,
50 Hz AC System for Ambient temperature -5°C to +40°C, fabricated in
compartmentalized designed made of CRCA sheet steel of 2.0mm thick for
framework & covers, 3 mm thick for gland plate i/c cleaning & finishing
complete with 9 tank process for powder coated of approved shade ( RAL - -
7032-Siemens gray or as approved by Engineer-in-Charge), having front
section (switch gear and control accessories) and rear section capacitor and
reactor, front and rear access, having suitable current carrying capacity,
extensible TPN Aluminum alloy bus bar of high conductivity, DMC/SMC bus
bar supports, bottom base channel of MS Section, fabrication shall be done
in transportable section, entire panel shall have common copper earth bar of
minimum size of 25mm x 5mm with 2 nos. earth studs, the earth terminals
provided on the body of capacitor bank shall also be bonded to the main
capacitor panel earth bus with 2 nos. 8 SWG or 6 SWG GI earth wires/
equivalent size of copper conductor cable, forced ventilation for maintaining
temperature rise not more than 5°C from ambient, interconnections,
connections with 14% detuned reactor and heavy duty 525 V ISI marked - -
Impregnated MPP(Metalized Polypropylene) Capacitor (IS 13340 Part -1 &
2) APFC Panel shall be in compliance with IS :16636 & CPWD
Specifications etc. as per below details
Suitable capacity MCCB Microprocessor base with O/C, S/C, E/L release of
TPN 50KA breaking capacity (Ics=Icu), ON, OFF, Trip, R, Y, B - LED
Indicating Lamp set along with required Instruments and accessories with
extended rotary handle and door interlocking arrangement. Current rating of
the Incomer in ampere shall be APFC Panel rating in KVAR x 1.4 x 1.5 or
Nearest higher standards rating.
(B) Instruments & Indications
i) 3-Phase current sensing APFC microprocessor relay/controller , advance
8/12 stages (8 stages for capacity below 100 KVAR and 12 stages 100
& above) with Communication Ethernet/RS485/SNMP port open protocol for
BMS integration as per approved by Engineering in charge and having
display of Phase wise V, A, PF, Cos-Phi, Kw, KVA, KVAR, THD-V , THD-I,
harmonics up to 31 level. 3 nos of dual core CT's accuracy class 1, 15VA at
incomer of PCC Panel for APFC relay.
Digitally signed by ARUN
ii) Auto Manual Selector switch, auxiliary contactors with timer for delay in
iii) Digital Multi function meter with LED Display for V, A, PF, KW, KVA,
KVAR, THD-V & I, Frequency.
iv) Suitable rating control transformer shall be provided for control and
indication circuit. - -
shall be protected by using suitable rating individual MCB's.
vi) Wiring of the control circuit shall be done by using 2.5 sq mm, FRLS
V grade, PVC insulated multi stranded copper control wire.
1.3 Amp per Sq.mm, TPN, Electrolytic grade Aluminum bus bar of capacity
1.25 times of incomer rating as per CPWD specification.
(D) Outgoings (APFC Section)
Selection of the capacitors combinations shall be for continuous rating and
each capacitor bank shall have suitable capacity Heavy Duty ISI Marked - -
Capacitor, capacitor duty contactor, the capacitor shall be mounted on
channel with base of perforated M S Powder coated sheet, connections inter
connections etc. and other features as per CPWD Specifications and
relevant IS Code having following:
(i) Capacitor bank ratings & stages shall be as per the technical
specifications sheet of NIT.
(ii) Capacitor will be MPP self healing type with discharge resistor, pressure
release mechanism.
(iii) Since Capacitor Voltage is 525 Volts, thus higher KVAR has to be
considered to get rated output at 415 Volts.
(iv) 14% Detuned Reactor of class H insulation & 150% linearity in series
(Note: Technical specifications sheet for selection of the capacitors - -
combinations shall be provided by the NIT Approving Authority with due
consideration of number of capacitors i.e. 1 KVAR, 2 KVAR, 3 KVAR, 5
KVAR, 10 KVAR.....for smooth correction).
Office Building L+P Panel
SITC of LT switchgear panels suitable for 433 V, 3 phase, 4 wire, 50 Hz
power distribution system. The panel shall be Indoor, free standing, floor
mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type
compartmentalised design fabricated out of 14 SWG CRCA sheet steel,
complete with colour coded, heat shrinkable PVC insulated, aluminium bus
bars and separate earth bus bar of adequate cross section through out the
length of the panel. The incoming and outgoing feeders shall be
accommodated in a fully segregated, modular multitier arrangement with - -
adequate size and distinct cable alley, bus bar alley/chamber. The panel shall
be complete with name plate, earthing, numbering, danger plate etc. as per
specifications and drawings as required. The panel shall withstand the fault
level of 50kA as per Single Line Diagram. The Panel shall also be capable to
communicate status like ON/OFF/ Trip through Modbus/Ethernet for major
component like ACB, MCCB, MCB & Multifunation meters.
The Main LT Panel shall use all draw out type breakers suitable for 415 V
AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Panel shall have
Buscoupler switching, auto operation of incommer and bus coupler, auto start
of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and
having following incomming and outgoing Air Circuit
Breakers,microprocessor release for overload, short circuit, instantaneous &
earthfault protection with Current & Voltage metering & LCD display. - -
Air Circuit Breaker with microprocessor release ge metering & LCD display ,
with ready to clsoe indicator, should have capability to communicate ON
/OFF/ Trip Status on Modbus/Ethernet and as per the detail specification of
ACB (Icu=Ics=Icw=65 KA (1 sec). MCCB, with microprocessor release
with LSIG protection functionand should not derate upto 50 decree
Centrigrate as per testing guideline as per IEC 60947-2 and all the ACB upto
2500Amp ACB should have same frame size LCD display for fault trip
history, haivng current limiting feature, double break mechanism & capability
to communicate ON /OFF/ Trip Status on Modbus/Ethernet. (65 KA Ics) - -
Digitally signed by ARUN
1 Nos. 315 Amp MCCB 16KA LSIG having S/C, E/F O/C protection, LCD
Display having specs as per attached annexture
R,Y,B Phase indication Lamp with control MCB
On, Off, Trip Status Indication with control MCB
Inbuilt Zone Slelective Interlocking function
Multifunction Meter
1 Nos. 400 Amp FP busbars of aluminium alloy as per SLD.
12 Nos. 63 Amp FP MCB 10 KA
On, Off, Trip Status Indication with control MCB
PDB+ACDB +Spare - -
9 Nos. 63 Amp FP MCB 10 KA
On, Off, Trip Status Indication with control MCB
LDB +Spare - -
Short Circuit Breaking capacity should not less than 16KA.
RELAYS AS PER SLD - -
Office Building HVAC Panel
SITC of LT switchgear panels suitable for 433 V, 3 phase, 4 wire, 50 Hz
power distribution system. The panel shall be Indoor, free standing, floor
mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type
compartmentalised design fabricated out of 14 SWG CRCA sheet steel,
complete with colour coded, heat shrinkable PVC insulated, aluminium bus
bars and separate earth bus bar of adequate cross section through out the
length of the panel. The incoming and outgoing feeders shall be
accommodated in a fully segregated, modular multitier arrangement with - -
adequate size and distinct cable alley, bus bar alley/chamber. The panel shall
be complete with name plate, earthing, numbering, danger plate etc. as per
specifications and drawings as required. The panel shall withstand the fault
level of 50kA as per Single Line Diagram. The Panel shall also be capable to
communicate status like ON/OFF/ Trip through Modbus/Ethernet for major
component like ACB, MCCB, MCB & Multifunation meters.
The Main LT Panel shall use all draw out type breakers suitable for 415 V
AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Panel shall have
Buscoupler switching, auto operation of incommer and bus coupler, auto start
of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and
having following incomming and outgoing Air Circuit
Breakers,microprocessor release for overload, short circuit, instantaneous &
earthfault protection with Current & Voltage metering & LCD display. - -
Air Circuit Breaker with microprocessor release ge metering & LCD display ,
with ready to clsoe indicator, should have capability to communicate ON
/OFF/ Trip Status on Modbus/Ethernet and as per the detail specification of
ACB (Icu=Ics=Icw=65 KA (1 sec). MCCB, with microprocessor release
with LSIG protection functionand should not derate upto 50 decree
Centrigrate as per testing guideline as per IEC 60947-2 and all the ACB upto
2500Amp ACB should have same frame size LCD display for fault trip
history, haivng current limiting feature, double break mechanism & capability
to communicate ON /OFF/ Trip Status on Modbus/Ethernet. (65 KA Ics) - -
1 Nos. 500 Amp ACB 16KA LSIG having S/C, E/F O/C protection, LCD
Display having specs as per attached annexture
R,Y,B Phase indication Lamp with control MCB
On, Off, Trip Status Indication with control MCB
Inbuilt Zone Slelective Interlocking function
Multifunction Meter
1 Nos. 650 Amp FP busbars of aluminium alloy as per SLD.
Digitally signed by ARUN
20 Nos. 63 Amp FP MCB + 63 Amp 300mAmp FP RCCB
On, Off, Trip Status Indication with control MCB
11 Nos. 63 Amp FP MCB 10 KA with 3-5KW S tar Delta Starter With
Potential Free Contact to be operated as per Fire Alarm Panel Command
On, Off, Trip Status Indication with control MCB
Ventilation & Pressurization Fan +Spare
Short Circuit Breaking capacity should not less than 16KA.
RELAYS AS PER SLD - -
5 UPS Output Panel MR 1.00 Set 1,12,100.00 1,12,100.00
SITC of LT switchgear panels suitable for 433 V, 3 phase, 4 wire, 50 Hz
power distribution system. The panel shall be Indoor, free standing, floor
mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type
compartmentalised design fabricated out of 14 SWG CRCA sheet steel,
complete with colour coded, heat shrinkable PVC insulated, aluminium bus
bars and separate earth bus bar of adequate cross section through out the
length of the panel. The incoming and outgoing feeders shall be
accommodated in a fully segregated, modular multitier arrangement with - -
adequate size and distinct cable alley, bus bar alley/chamber. The panel shall
be complete with name plate, earthing, numbering, danger plate etc. as per
specifications and drawings as required. The panel shall withstand the fault
level of 50kA as per Single Line Diagram. The Panel shall also be capable to
communicate status like ON/OFF/ Trip through Modbus/Ethernet for major
component like ACB, MCCB, MCB & Multifunation meters.
The Main LT Panel shall use all draw out type breakers suitable for 415 V
AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Panel shall have
Buscoupler switching, auto operation of incommer and bus coupler, auto start
of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and
having following incomming and outgoing Air Circuit
Breakers,microprocessor release for overload, short circuit, instantaneous &
earthfault protection with Current & Voltage metering & LCD display. - -
Air Circuit Breaker with microprocessor release ge metering & LCD display ,
with ready to clsoe indicator, should have capability to communicate ON
/OFF/ Trip Status on Modbus/Ethernet and as per the detail specification of
ACB (Icu=Ics=Icw=65 KA (1 sec). MCCB, with microprocessor release
with LSIG protection functionand should not derate upto 50 decree
Centrigrate as per testing guideline as per IEC 60947-2 and all the ACB upto
2500Amp ACB should have same frame size LCD display for fault trip
history, haivng current limiting feature, double break mechanism & capability
to communicate ON /OFF/ Trip Status on Modbus/Ethernet. (65 KA Ics) - -
1 Nos. 125 Amp MCCB 16KA
R,Y,B Phase indication Lamp with control MCB
On, Off, Trip Status Indication with control MCB
Inbuilt Zone Slelective Interlocking function
Multifunction Meter
1 Nos. 160 Amp FP busbars of aluminium alloy as per SLD.
8 Nos. 32 Amp FP MCB
On, Off, Trip Status Indication with control MCB
UPS DB +Spare - -
Short Circuit Breaking capacity should not less than 16KA.
RELAYS AS PER SLD - -
Total For Subhead-IV Distribution Panel
Digitally signed by ARUN
E Subhead-V L.T Cable Work
Supply of Power Cables,Solid Aluminum conductor up to 10 sqmm balance
stranded conductor,XLPE Insulated,cores laid up, PVC tape
innersheathed,unarmoured/Armour(Aluminium wire for single core up to 70
sqmm balance Aluminium strip, Glavanised wire for cables upto 2x16 sqmm,
3x10 sqmm & balance all galvanised steel strip),extruded PVC Type ST2
sheathed,650/1100V grade as per IS 7098(Part 1) 1988
a 6 sq. mm 2 core RA-8 Meter 132.12 -
e 95 sq. mm 3-1/2 core RA-12 - Meter 727.10 -
Supply ofPower/Control Copper Cables,Solid Copper conductor,XLPE
Insulated,cores laid up, PVC tape innersheathed,Unarmoured/Armour
(Glavanised wire for cables up to 14x1.5 sqmm, 9x2.5 sqmm,2x16 sqmm,
3x10 sqmm,4x10sqmm balance all galvanised steel strip),extruded PVC Type
ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988
Supply and fixing of brass nickle plated compression gland for PVC insulated
& armoured served sheathed, underground cable including rubber ring etc.
complete in all respect. The armouring of the cable shall be properly
3 connected with the earth as per direction of Engineer-Incharge. - -
Laying of one number PVC insulated and PVC sheathed / XLPE
4 power cable of 1.1 KV grade of following size in the existing 7.5
RCC/ HUME/ METAL pipe as required.
a Upto 35 sq. mm 7.5.1 Meter 37.00 -
b Above 35 sq. mm and upto 95 sq. mm 7.5.2 Meter 57.00 -
c Above 95 sq. mm and upto 185 sq. mm 7.5.3 Meter 77.00 -
d Above 185 sq. mm and upto 400 sq. mm 7.5.4 330.00 Meter 134.00 44,220.00 -
Laying and fixing of one number PVC insulated and PVC
5 sheathed / XLPE power cable of 1.1 KV grade of following size 7.8
on cable tray as required.
a Upto 35 sq. mm (clamped with 1mm thick saddle) 7.8.1 1,685.00 Meter 45.00 75,825.00 -
b Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 7.8.2 150.00 Meter 92.00 13,800.00 -
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat
Digitally signed by ARUN
d Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) 7.8.4 220.00 Meter 185.00 40,700.00 -
Providing, laying and fixing following dia RCC pipe NP2 class
(light duty) in ground complete with RCC collars, jointing with
cement mortar 1:2 (1 cement : 2 fine sand) including trenching
(75 cm deep) and refilling etc as required. 300mm Dia
Supplying and laying of following size DWC HDPE pipe ISI marked along
with all accessories like socket, bend, couplers etc.
conforming to IS 14930, Part II complete with fitting and cutting,
jointing etc. in the existing trench, complete as required
Total For Subhead-V L.T Cable Work
F Subhead-VI External Lighting Work
EXTERNAL LIGHT FEEDER PILLAR -
Supply installing testing & commissioning of out door type IP66 with
additional canopy street light feeder pillar (Distribution Panel)
1 compartmentalised design, dust tight & vermin proof made out of 14 gauge MR 1.00 Each 1,22,130.00 1,22,130.00
M.S. sheet, stove powder coated complete as required with following
incomming & outgoing as per detail below.
100 Amp. 10 KA FP MCCB 1 No. -
Suitable digital contractor and timer for down & dusk -
100 Amp. TPN Alu. Bus bar -
32 Amp. 10KA DP MCB 9 No. -
40 Amp. 10KA FP MCB 2 No. -
Supply of Power Cables,Solid Aluminum conductor up to 10 sqmm balance
stranded conductor,XLPE Insulated,cores laid up, PVC tape
innersheathed,unarmoured/Armour(Aluminium wire for single core up to 70
sqmm balance Aluminium strip, Glavanised wire for cables upto 2x16 sqmm,
3x10 sqmm & balance all galvanised steel strip),extruded PVC Type ST2
sheathed,650/1100V grade as per IS 7098(Part 1) 1988
Supply and fixing of brass nickle plated compression gland for PVC insulated
& armoured served sheathed, underground cable including rubber ring etc.
complete in all respect. The armouring of the cable shall be properly
3 connected with the earth as per direction of Engineer-Incharge. - -
Laying of one number PVC insulated and PVC sheathed / XLPE
4 power cable of 1.1 KV grade of following size in the existing 7.5
RCC/ HUME/ METAL pipe as required.
Digitally signed by ARUN
Supplying and laying of following size DWC HDPE pipe ISI marked along
with all accessories like socket, bend, couplers etc.
conforming to IS 14930, Part II complete with fitting and cutting,
jointing etc. in the existing trench, complete as required
Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for
earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre
from the bottom complete with earthing lead of No. 6 to 8SWG GI wire in
G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire
and pipe will be extra) upto switch board, 30cm square C.I. box with hinged
cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and
salt at least 150mm thick alround etc. as per directions of Engineer-in-charge DSR
6 complete in all respects as per drawing. 2022 6.00 each 6,855.00 41,130.00 - -
Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for
earthing with its top at least 3 metres below ground level complete with
20mm dia G.I. pipe and funnel for watering and one earthing lead of two no.
8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron
to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square
C.I. frame with hinged cover masonry housing alternate layers of
charcoal/coke and salt at least 150mm thick alround etc. as per directions of 2.00 7,472.00 14,944.00 - -
Engineer-in-charge complete in all respect.
Supply and laying of 25 mm X 3mm G.I. strip from earth electrode directly in
the ground as required complete in all respect.
Supply and fixing of 1 no. 8SWG GI wire in 15mm dia GI pipe for earthing,
laid in ground or in wall duly concealed including the cost of cement, sand,
labour, T&P other material required for proper completion of the work as
directed at site.
Supply & fixing of 3 mtr PU painted Pole of approved make having 3mm
thikness with RCC foundation including the cost of foundation, foundation
bolts, excavation & back filling and Required T&P completee in all respect.
Supply and fixing of LED Post top light Fitting having die cast aluminium
body toughen glass/UV Stablized PC cover and lenses for 45 Watt.
Confirming to IP66 IK 07 with above Protectionhaving company LOGO
engraved complete in all respect.
7200-8640 system lumen, High Power LED with lenses , >120lm/W,
PF>0.95, potted driver set in metal housing (Not circuitry) Phase to phase
11 protection at 440V, >300V auto cut and restart feature, 4KV internal surge MR 33.00 Each 7455.24 2,46,022.92
protection with 5 year warrenty. CAT-AAA
Total For Subhead-VI External Lighting Work
G Subhead-VII Earthing Work
Digitally signed by ARUN
Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for
earthing with its top at least 3 metres below ground level complete with
20mm dia G.I. pipe and funnel for watering and one earthing lead of two no.
8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron
to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square
C.I. frame with hinged cover masonry housing alternate layers of
charcoal/coke and salt at least 150mm thick alround etc. as per directions of
Engineer-in-charge complete in all respect.
Supply and burying of 600mm x 600mm x 3mm copper plate vertically for
earthing with its top at least 3 metres below ground level complete with
20mm dia G.I. pipe and funnel for watering and two earthing lead of two no. 8
SWG copper wire in 15mm dia G.I. pipe up to switch board (from appron to
switch board the cost of G.I. pipe and copper wire will be extra) 30cm square
C.I. frame with hinged cover masonry housing alternate layers of DSR
2 charcoal/coke and salt at least 150mm thick alround etc. complete in all 2022 2.00 each 13,838.00 27,676.00 - -
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below
ground as strip earth electrode, including connection/ terminating with nut,
bolt, spring, washer etc. as required. (Jointing shall be done by overlapping
and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as
strip earth electrode, including connection/ terminating with G.I. nut, bolt,
spring, washer etc. as required. (Jointing shall be done by overlapping and
with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe
5 from earth electrode including connection with brass nut, bolt, spring, washer 5.10 120.00 Meter 1,551.00 1,86,120.00 - -
excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from
6 earth electrode including connection with G.I. nut, bolt, spring, washer 5.11 220.00 Meter 706.00 1,55,320.00 - -
excavation and re-filling etc. as required.
Total For Subhead-VII Earthing Work
H Subhead-VIII Panel Protection System
2kg capacity seamless Alluminium cylinder Paso approved stored pressure
type clean agent fire extinguisher alongwith all necessary fitting filled with
clean agent FK-5-1-12 complete having operating pressure between 15 bar
1 etc. as required UL & FM listed gas. MR 8.0 Each 65,490.00 5,23,920.00
5kg capacity seamless Alluminium cylinder Paso approved stored pressure
type clean agent fire extinguisher alongwith all necessary fitting filled with
clean agent FK-5-1-12 complete having operating pressure between 15 bar
2 etc. as required UL & FM listed gas. MR 2.0 Each 89,892.40 1,79,784.80
SITC of Pneumatic Heat detection tube red color made by special modified polyamide
(PA), UL and LPCB standard, having burst temperature 100°C to 120°C, inner
diameter 4 mm, outer diameter 6 mm, pressurized with nitrogen at 15 bar pressure for
automatic detection and suppression system
Digitally signed by ARUN
SITC of End of line adapter along with pressure gauge working pressure 25 bar. UL
SITC of End of Line Plug for automatic fire suppression System used for fitting at
5 tube end to terminate the point. Fitting made by brass nickel plated material. UL MR 10 Each 6,442.80 64,428.00
6 SITC of Pressure Switch at 15 bars. UL approved. MR 10 Each 11,658.40 1,16,584.00
SITC of T connection suitable for 4 / 6 mm. diameter pressurized tubes, brass nickel
plated material with maximum working pressure 25 bar. UL approved.
SITC of Master Control Unit micro processor based 4 zone inbuilt GSM dialer audio
visual alarm control panel, 2NO/NC potential free relay contacts discharge LED
indicator, battery LED indicator, system status indicator and AC power ON LED
indicator with inbuilt battery backup 24h .
Total For Subhead-VIII Clean Agent Suppression System
I Subhead-IX Cable Tray Work
Supplying and installing following size of perforated painted with powder
coating M.S. cable trays with perforation not more than 17.5%, in convenient
sections, joined with connectors, suspended from the ceiling with M.S.
suspenders including bolts & nuts, painting suspenders etc. as required.
a 100 mm width X 50 mm depth X 1.6 mm thickness 4.1.1 50.00 Meter 543.00 27,150.00 - -
b 300 mm width X 50 mm depth X 1.6 mm thickness 4.1.4 100.00 Meter 777.00 77,700.00 - -
c 450 mm width X 62.5 mm depth X 2 mm thickness 4.1.10 100.00 Meter 1,224.00 1,22,400.00 - -
d 600 mm width X 62.5 mm depth X 2 mm thickness 4.1.11 50.00 Meter 1,463.00 73,150.00 - -
e 900 mm width X 62.5 mm depth X 2 mm thickness 4.1.13 - Meter 1,952.00 - - -
Total For Subhead-IX Cable Tray Work
J Subhead-X On Grid Solar Power Backup System
On Grid Solar System Work
Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic
Power Plant conformington MNRE specifications as amended, consisting of
Mono Crystalline silicon solar cells, netmetering facility, necessary
protections, earthing, mounted on Aluminium/GI structure of suitable strength
with following components complete as required:-a)Solar Photovoltaic
1 Module of capacity 330Wp or above, manufactured in India, conforming to 50.00 KWp 61,060.00 30,53,000.00 - -
IS14286/IEC61215, IS/IEC61730-Part-1, IS/IEC61730-Part-2. Solar
Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV
modules used in solar power plants/systems must be warranted for their
output peak watt capacity, which should not be less than 90% at the end of
10years and 80% at the end of 25 years
Digitally signed by ARUN
b)Power Conditioning Unit (PCU) of 350-800VDC Input voltage range and
400VAC, three phase, 4wire, 50Hz+/-2.5Hz, out put voltage suitable to
generate AC Power with efficiency not less than 97%, total harmonic
distortion less than 3% and suitable for ambient temperature from
0to50degree C. The PCU shall adjust the voltage and frequency level to suit - - -
the Grid Voltage Frequency.c) Data Monitoring System complete with
d) Fixing of Array junction box & Main junction box with IP65 protection
and termination arrangement for in coming and outgoing cable alongwith
glands, lugs and other accessories etc. as required.
e) Lightning and surge voltage
protection.f)Connections&Interconnectionsbysupplying&fixingrequiredsizeX
LPEinsulatedcopperconductor1.1kVgradearmouredpowerandcontrolcablesbet
weensolarmodules,mainpowercabletogridsupplyPCUunitalongwithsupplying
&fixingofnecessarychannel/conduitlugsandotheraccessoriesetc.asrequired.
Subhead-X On Grid Solar Power Backup System
Digitally signed by ARUN
SCHEDULE OF QUANTITIES FOR PLUMBING WORKS
CRC AT JAMDOLI ,AGRA ROAD ,JAIPUR(RAJASTHAN)
S.NO NAME OF SUB-HEAD
DSR (2023) M.R.
I INTERNAL PLUMBING
A. SUB HEAD-1:SANITARY INSTALLATIONS AND C.P FITTINGS 778730.60 1941684.37
B. SUB HEAD-II:SOIL WASTE , VENT PIPE AND FITTINGS 76038.00 0.00
C. SUB HEAD-III:INTERNAL RAIN WATER DRAINAGE WORK 193352.05 459945.35
SUB HEAD-IV:INTERNAL RAIN WATER SUPPLY WORK 1279609.20 851882.20
Digitally signed by ARUN
SCHEDULE OF QUANTITIES FOR PLUMBING WORKS
CRC AT JAMDOLI ,AGRA ROAD ,JAIPUR(RAJASTHAN)
INTERNAL PLUMBING WORKS
RATE(Rs) AMOUNT(Rs)
DSR(2023) DESCRIPTION QTY UNIT
SANITARY INSTALLATIONS & C.P FITTINGS
Providing and fixing white vitreous china extended wall mounting water
closet of size 780x370x690 mm of approved shape including providing &
17.78 DSR fixing white vitreous china cistern with dual flush fitting, of flushing capacity 33 each 14999.15 4,94,971.95
3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and
cistern fittings, nuts, bolts and gasket etc complete.
Providing & fixing white vitreous china undercounter basin in white with C.I.
brackets painted white, with rubber plug, 32mm C.P. brass waste of
standerd pattern including cutting & making good the walls wherever
a)White 581mm x 402mm undercounter Wash basin size. 38 each 17665.20 671277.67
17.28 DSR Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C.
waste fittings complete.
17.28.1 Semi rigid pipe
17.31 DSR Providing and fixing 600x450mm bevelled edge mirror of superior glass (of
approved quality) complete with 6mm thick hard board ground fixed to 34 each 1607.95 54,670.30
wooden cleats with C.P. brass screws and washers complete.
17.10 DSR Providing and fixing Stainless Steel AISI 304(18/8) kitchen sink as per IS :
13983 with C.I. brackets and stainless steel plug 40mm including painting of
fittings and brackets, cutting and making good the walls wherrerever
17.10.1.1 DSR Kitchen sink with drain board Size 510x1040 mm bowl depth 250mm 1 each 6945.60 6,945.60
DSR Kitchen sink without drain board Size 610x510 mm bowl depth 200 mm
Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass
chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary
C.P. brass unions complete, including painting of fittings and brackets, cutting and making
good the wall wherever required :
Providing and fixing mirror of superior glass (of approved quality) and of
required shape and size with plastic moulded frame of approved make and
17.32 shade with 6 mm thick hard board backing :
17.32.4 Rectangular shape 1500x450 mm 4 each 2093.00 8,372.00
Providing and fixing white vitreous china battery based infrared sensor
operated urinal of approx. size 610 x 390 x 370 mm having pre & post
flushing with water (250 ml & 500 ml consumption), having water inlet from
back side, including fixing to wall with suitable brackets all as per
manufacturers specification and direction of Engineer-in-charge.( K-26474IN-
Providing and fixing stone slab table rubbed, edges rounded and polished of
size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a
chase of appropriate width with chase cutter and embedding the stone in the
8.10 DSR chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse
sand: 4graded stone aggregate 6mm nominal size) as per direction of
Engineer-in-charge and finished smooth.
8.10.2 Granite Stone of approved shade 20 Sqm. 4051.85 81,037.00
CP Brass fittings
18.21 Providing and fixing unplasticised PVC connection pipe with brass unions.
18.21.2 DSR 45 cm length
18.21.2.1 DSR 15 mm nominal bore 40 each 97.75 3,910.00
Providing and fixing Health faucet with white side spray, metal hose in
polished chrome with flexible tube upto 1 metre long with S.S. triangular
M.R. plate to Eureopean & Wall moutain type W.C. of quality and make as 33 each 3549.95 1,17,148.19
approved by Engineer - in- charge.
Providing and fixing 2-way bib tap in polished chrome (kohler/Roca/
American standard)
Providing and fixing 2 handle wall kitchen mixer in polished chrome of
approved quality conforming to IS standards and weighing not less than 690
gms. ( for sink)
M.R. a) 15 mm nominal bore 0 each 17580.68 0.00
Providing and fixing angle valve in polished chrome for basin mixer and
gyser points of approved quality conforming to IS:8931
M.R. a) 15 mm nominal bore 78 each 4057.08 3,16,451.93
Pillar tap in polished chrome Basin Mixer with Popup Waste System.
Sink Mixer with Swinging Spout (Table Mounted Model) with 450mm Long
M.R. Braided Hoses (kohler/Roca/ American standard) 0 each 0.00 0.00
Providing and fixing CP Brass diverter wall mixer of quality & make as
approved by Engineer in charge. (For bath)
M.R. 15 mm diameter 0 each 5157.30 -
Providing and fixing Square showerhead with shower arm in polished chrome
M.R. with 15 or 20mm inlet 0 0.00
M.R. 150 mm diameter
Providing and fixing C.P. brass stop cock (concealed) of standard design and
of approved make conforming to IS:8931: each 670.45
18.52.1 DSR 15mm nominal bore
Providing and fixing 350mm bottle trap without drain in polished chrome of
M.R. approved quality & make and as per the direction of Engineer-in-charge. 38 each 4902.31 186287.60
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high
17.71 DSR and 112 mm distance from wall of standard shape with bracket of the same 27 each 168.35 4,545.45
materials with snap fittings of approved quality and colour, weighing not less
Digitally signed by ARUN
Providing and fixing PTMT towel rail complete with brackets fixed to wooden
17.73 DSR cleats with CP brass screws with concealed fittings arrangement of approved
quality and colour.
450 mm long towel rail with total length of 495 mm, 78 mm wide and
effective height of 88 mm, weighing not less than 170 gms.
17.34 DSR Providing and Fixing Toilet Paper Holder:
C.I. SOIL WASTE & VENT PIPES AND FITTINGS
17.35 Providing & fixing Cast Iron pipe soil, waste and vent pipes.
Providing and fixing GI pipes complete with GI fittings and clamps,
including cutting and making good walls etc. ( for wash basin waste )
18.10.4 DSR 32mm dia nominal bore 114 Metre 667.00 76,038.00
INTERNAL RAIN WATER DRAINAGE WORK
19.2. Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10
graded stone aggregate 20mm nominal size) around P.V.C Soil and waste
pipe including bed concrete as per standard design(embedded in the flooring
19.2.1 DSR 110 mm dia
19.2.1 DSR 150 mm dia
12.41 Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes
conforming to IS: 13592 Type A including jointing with seal ring conforming
to IS: 5382 leaving 10mm gap for thermal expansion.
Providing and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN
Conventional system for soil and waste water pipes conforming to (HSN
CODE: 3917) Type B including jointing with seal ring. (i) Double socketed
Providing and fixing on wall face unplasticised - PVC moulded
fittings/accessories for unplasticised Rigid PVC pipes including jointing with
seal ring leaving 10 mm gap for thermal expansion.
M.R. g) Providing & fixing UPVC Coupler
M.R. a) Providing & fixing UPVC 90˚ elbow Each
MR Bend 87.5 degree
MR Shoe (Plain)
MR Single Tee with door
MR Single Tee without Door
Providing and fixing on wall face unplasticised PVC moulded
12.42 fittings/accessories for unplasticised Rigid PVC rain water pipes conforming
to IS:13592 Type A including jointing with seal ring conforming to IS:5382
leaving 10mm gap for thermal expansion.
12.42.1 DSR Coupler
12.42.5.2 DSR Bend 87.5 degree
12.42.6 DSR Shoe (Plain)
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15
cm diameter and weighing not less than 440 grams.
12.43 Providing and fixing unplasticised-PVC pipe clips of approved design to
unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood
plugs, screwed with MS screws of required length including cutting brick
work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and
making good the wall etc. complete.
Making khurras 45x45 cm with average minimum thickness of 5 cm cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20
12.22 DSR mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 16 Each 298.25 4,772.00
mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat
cement,punning,rounding the edges and making and finishing the outlet
complete. TOTAL [III] 1,93,352.05 459945.35
INTERNAL WATER SUPPLY WORKS
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having
thermal stability for hot & cold water supply including all CPVC plain & brass
threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This
includes jointing of pipes & fittings with one step CPVC solvent cement and
the cost of cutting chases and making good the same including testiang of
joints complete as per direction of Engineer in Charge.
Concealed work including cutting chases and making good the walls etc.
18.8.1 DSR 15mm dia nominal outer dia pipes 497 Rm. 497.80 2,47,406.60
18.8.2 DSR 20mm dia nominal outer dia pipes 355 Rm. 537.60 1,90,848.00
18.8.3 DSR 25mm dia nominal outer dia pipes 355 Rm. 627.25 2,22,673.75
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having
thermal stability for hot & cold water supply, including all CPVC plain & brass
threaded fittings, including fixing the pipe with clamps at 1.00 m spacing.
This includes jointing of pipes & fittings with one step CPVC solvent cement
and testing of joints complete as per direction of Engineer in Charge.
Internal work-Exposed on wall
18.7.2 DSR 20mm dia nominal bore 60 Metre 335.00 20,100.00
18.7.3 DSR 25mm dia nominal bore 80 Metre 401.55 32,124.00
Digitally signed by ARUN
18.7.4 DSR 32mm dia nominal bore 40 Metre 518.75 20,750.00
18.7.5 DSR 40mm dia nominal bore 40 Metre 702.95 28,118.00
18.7.6 DSR 50mm dia nominal bore 40 Metre 934.15 37,366.00
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having
thermal stability for hot & cold water supply including all CPVC plain & brass
threaded fittings This includes jointing of pipes & fittings with one step CPVC
solvent cement, trenching, refilling & testing of joints complete as per
direction of Engineer in Charge.
18.9.7 DSR 65mm dia nominal bore 80 Metre 1674.40 1,33,952.00
18.9.8 DSR 80mm dia nominal bore 0 Metre 2166.35
18.17 Providing and fixing gun metal gate valve with wheel of approved quality.
18.17.1A DSR 20mm dia nominal bore 2 Each 539.95 1,079.90
18.17.1 DSR 25mm dia nominal bore 3 Each 622.40 1,867.20
18.17.2 DSR 32mm dia nominal bore 3 Each 689.60 2,068.80
17.17.3 DSR 40mm dia nominal bore 2 Each 826.10 1,652.20
18.17.4 DSR 50mm dia nominal bore 1 Each 1026.65 1,026.65
18.17.5 DSR 65mm dia nominal bore 1 Each 1742.15 1,742.15
18.17.6 DSR 80mm dia nominal bore 0 Each 2604.55
18.18 Providing and fixing ball valve (brass) of approved quality, High or low
pressure, with plastic floats complete :
18.18.1 DSR 15 mm nominal bore 2 Nos. 406.85 813.70
18.18.2 DSR 20 mm nominal bore 8 Nos. 462.50 3,700.00
18.18.3 DSR 25 mm nominal bore 5 Nos. 464.05 2,320.25
18.48 18.48 Providing and placing on terrace (at all floor levels) polyethylene water
storage tank, IS : 12701 marked, with cover and suitable locking
arrangement and making necessary holes for inlet, outlet and overflow
pipes but without fittings and the base support for tank. 3,30,000.00
30000.00 Per litre 11.00
Providing and fixing motorized butterfly valves the valve should
be able to oprate with hot/cold water medium between 20---
120 degree working temperature, the nominal pressure of the
valve should be PN 16, leakage rate through the valve disc
should be Rate-A Bubble tight to EN1266-1 with integrated
flange sealing should ensure positive connection of the valve
body seat ring and valve disc and provide a complete isolation
of the media from the body. The disc casting should be
precision machined and should give a smooth and close disc-to-
M.R. seat relationship. The stem bearing should comprise of non
corrosive PTFE bushing to completely isolate the valve seat from
the body, resulting in increase control of the valve disc, lower
valve seating torque and longer valve life. The disc should be
stainless steel to offer a good corrosion resistance, superior
resistance to a broad range of chemical enviorments as well as
very low co-efficient of friction and excellent resistance to
impact and ultra-violet radiation. For temperatures and rust
proof operation the valve disc should be stainless steel material.
65 mm nominal bore 1.00 Nos. 34904.41 34904.4118
M.R. Supply of wall hanging drinking water cooler with bottle filler facility,
made by stainless steel top and heavy duty galvanized steel frame. With
cooling capacity, ADA Compliant, size 472 mm Depth X 447mm width,
flexible bubbler guard , operated between 50 to 120 PSI, Chiller unit
Suitable to R134a Refrigerant, Adjustable thermostat control, suitable for
220-230v/50-60 hz A/C Supply Complete with all accessories which include
MD-CU29, which is an EPA registered antimicrobial copper that fights off
microorganisms which include MRSA and e-coli. The water Fountain shall
possess NSF-USA, Green building, energy star saving certification, and to be
placed at different location of buidling. As per Enginner Incharge-
M.R. RO Plant 150 LPH (Liter per hour)
PLANT CAPACITY - 150 LPH
ELECTRICAL CONNECTION - 415 V, 3 PHASE, 50 HZ
TDS - < 100 PPM
500L STORAGE TANK AND DRINKING FOUNTAIN
Digitally signed by ARUN
SCHEDULE OF QUANTITIES FOR PLUMBING WORKS
PROPOSED CONTRACTION OF COMPOSITE REGIONAL CENTRE(CRC) AT JAMDOLI
EXTERNAL PLUMBING
S.NO NAME OF SUB-HEAD
SOR/DSR (Rs MR(Rs)
I EXTERNAL SEWERAGE SYSTEM 753547.70 0.00
II EXTERNAL WATER SUPPLY SYSTEM 209579.30 0.00
III RAIN WATER DRAINAGE WORK 302773.60 0.00
IV HARVESTING PITS 1216794.05 0.00
V TUBE WELL/BOREWELL 176952.90 26160.25
Digitally signed by ARUN
(COST OF EXTERNAL SEWERAGE, DRAINAGE & EXTERNAL WATER SUPPLY WORKS)
RATE (RS) AMOUNT(Rs
SOR/DSR.23/M.R DESCRIPTION QTY. UNIT
DSR-2023 MR D.S.R -2023 MR AMOUNT
I COST OF SEWERAGE WORKS
DSR Excavating trenches in all kinds of soil of required width for
pipes. including excavation for sockets and dressing of sides,
ramming of bottoms, including getting out the excavated soil &
1 then returning the soil as required, in layers not exceeding 20 cm
in depth including consolidating each deposited layer by ramming,
watering, etc & disposing of surplus excavated soil as directed
within a lead of 50m.
DSR 2.10.1.2 Pipes 80 mm to 300 mm diameter 170 metre 352.15 59865.50
Open timbering in trenches including shuttering and shoring
complete. (Measurement to be taken of the face area timbered)
DSR 2.20.1 Depth not exceeding 1.5 meter 10 Sqm 72.05 720.50
DSR Providing and laying Non pressure NP 2 class (light duty) RCC
pipe with collars jointed with stiff mixture of cement mortar in
the proportion of 1:2 (1cement : 2 fine sand ) including testing
of joints etc. complete.
DSR 19.6.2 150 mm. dia. RCC Pipes 170.00 metre 556.45 94596.50
DSR 19.6.3 250 mm. dia. RCC Pipes 10.00 metre 899.80 8998.00
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse
4 sand : 10 graded stone aggregate 40mm nominal size) upto the
haunches of pipes including bed concrete as per standard design
Constructing brick masonry manhole in cement mortar 1:4 (1
cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2
coarse sand :4 graded stone aggregate 20mm nominal size),
foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded
stone aggregate 40mm nominal size) inside plastering 12mm thick
with cement mortar 1:3 (1 cement :3 coarse sand) finished with
floating coat fo neat cement and making channels in cement
concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone
aggregate 20mm nminal size) finished with a floating coat of neat
cement complete as per standard design.
Inside size 90x80cms and 45cms deep including CI cover with
frame (light duty) 455x610mm internal diamensions total weight of
5 cover and frame to be not less than 38 kg (weight of cover 23 kg
and weight of frame 15kg).
DSR With common burnt clay FPS (non modular) bricks of class
19.7.1 designation 75
DSR 19.7.1.1 (i) For Sewer Line 6 each 12770.55 76623.30
6 Extra for depth for manholes:
DSR Size 90x80cm with With common burnt clay FPS (non modular)
bricks of class designation 7.5 8825.40
Inside size 120x90cms and 90cms deep including CI cover with
frame (MEDIUM duty) 455x610mm internal diamensions total
7 weight of cover and frame to be not less than 116 kg (weight of
cover 58 kg and weight of frame 58kg).
DSR With common burnt clay FPS (non modular) bricks of class
DSR 19.7.2.1 (i) For Sewer Line 6.00 each 26405.50 158433.00
8 Extra for depth for manholes:
Size 120x90cm with With common burnt clay FPS (non modular)
bricks of class designation 7.5
Constructing brick masonry circular type manhole 0.91 m internal
dia at bottom and 0.56m dia at top in cement mortar 1:4 (1
cement: 4 coarse sand), inside cement plaster 12 mm thick with
cement mortar 1:3 (1 cement : 3 coarse sand) finished with a
floating coat of neat cement, foundation concrete 1:3:6 mix (1
9 DSR 19.9.1 cement : 3 coarse
sand : 6 graded stone aggregate 40 mm nominal size), and making
necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse
sand : 4 graded stone aggregate 20 mm nominal size) finished
with a floating coat of neat cement, all complete as per standard
0.91 m deep with S.F.R.C. cover and frame (heavy duty,
HD-20 grade designation) 560 mm internal diameter con forming
to I.S. 12592, total weight of cover and frame to be not less than
182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand
: 4 graded stone aggregate 20 mm nominal size) including
centering, shuttering all complete. (Excavation, foot rests and
12mm thick cement plaster at the external surface shall be paid for
19.9.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. 6.00 each 12725.00 76350.00
10 Extra for depth for manholes:
Extra depth for circular type manhole 0.91m internal dia (at
bottom) beyond 0.91 m to 1.67 m
DSR Constructing brick masonary circular manhole 1.22 m internal dia
at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :
4 coarse sand) inside cement plaster 12mm thick with cement
mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat
of neat cement foundation concrete 1:3:6 (1 cement :3 coarse
9 sand : 6 graded stone aggregate 40mm nominal size) and making
necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse
sand : 4 graded stone aggregate 20mm nominal size) finished with
a floating coat of neat cement, all complete as per standard
DSR 1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade
designation) 560mm internal diameter conforming to I.S. 12592,
total weight of cover and frame to be not less than 182 kg. fixed in
cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone
aggregate 20mm nominal size) including centering, shuttering all
complete. (Excavation, foot rests and 12mm thick cement plaster
at the external surface shall be paid for separately):
19.11.1 Digitally signed by ARUN
DSR With common burnt clay F.P.S. (non modular) bricks of class
19.11.1.1 designation 7.5 2.00 each 24702.75
DSR Extra depth for circular type manhole 1.22m internal dia (at
10 bottom) beyond 1.68m to 2.29m
DSR With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 19722.90
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm
11 DSR 19.15.1 cementm concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone 24.00 each 544.70 13072.80
aggregate 20 mm nominal size) as per standard design :
TOTAL COST OF EX. SEWERAGE 753547.70 0.00
COST OF EXTERNAL WATER SUPPLY WORKS
RISING MAIN AND BYE PASS ARRANGEMENT
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply including all
CPVC plain & brass threaded fittings This includes jointing of pipes
& fittings with one step CPVC solvent cement, trenching, refilling &
testing of joints complete as per direction of Engineer in Charge.
DSR 18.9.7 50 mm nominal dia Pipes 80 RM 1674.40 133952.00
DISTRIBUTION SYSTEM
Providing and fixing gun metal gate valve with C.I. wheel of
approved quality (screwed end) :
DSR Constructing brick masonry chamber 600 x 600 x 750 mm
inside with F.P.S. brick work in cement mortar 1:4 (1 cement : 4
coarse sand) for Sluice Valve / Air Valve, with C. I. surface box
100 mm top diameter, 160 mm bottom diameter and 180mm
deep (inside) with chained lid and RCC top slab with 1 : 2 : 4 mix
14 18.33.1 (1 cement : 2 coarse sand : 4 grade stone aggregate 20 mm 6.00 Each 10862.40 65174.40
nominal size); necessary excavation, foundation concrete 1:5:10
(1 cement : 5 fine sand: 10 graded stone aggregate 40 mm
nominal size) and inside plastering with cement mortar 1 : 3 (1
cement : 3 coarse sand ) 12 mm thick finished with a floating
coat of neat cement complete as per standard design
TOTAL COST OF EX.WATER SUPPLY 209579.30 0.00
III RAIN WATER DRAINAGE NETWORK
Excavating trenches in all kinds of soil of required width for
pipes. including excavation for sockets and dressing of sides,
ramming of bottoms, including getting out the excavated soil &
15 DSR then returning the soil as required, in layers not exceeding 20 cm
in depth including consolidating each deposited layer by ramming,
watering, etc & disposing of surplus excavated soil as directed
within a lead of 50m.
up to 1.50 m depth
2.10.1.2 Pipes 80 mm to 300 mm diameter 80.00 metre 352.15 28172.00
Providing and laying Non pressure NP 2 class (light duty) RCC
pipe with collars jointed with stiff mixture of cement mortar in
the proportion of 1:2 (1cement : 2 fine sand ) including testing
of joints etc. complete.
DSR 19.6.2 150 mm. dia. RCC Pipes 80.00 metre 556.45 44516.00
DSR 19.6.3 250 mm. dia. RCC Pipes 30.00 metre 899.80 26994.00
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse
17 DSR sand : 10 graded stone aggregate 40mm nominal size) upto the
haunches of pipes including bed concrete as per standard design
Constructing brick masonry manhole in cement mortar 1:4 (1
cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2
coarse sand :4 graded stone aggregate 20mm nominal size),
foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded
DSR 19.7 stone aggregate 40mm nominal size) inside plastering 12mm thick
with cement mortar 1:3 (1 cement :3 coarse sand) finished with
floating coat fo neat cement and making channels in cement
concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone
aggregate 20mm nminal size) finished with a floating coat of neat
cement complete as per standard design.
Inside size 90x80cms and 45cms deep including CI cover with
frame (light duty) 455x610mm internal diamensions total weight of
18 19.7.1 cover and frame to be not less than 38 kg (weight of cover 23 kg
and weight of frame 15kg).
With common burnt clay FPS (non modular) bricks of class
19 DSR Extra for depth for manholes:
Size 90x80cm with With common burnt clay FPS (non modular)
bricks of class designation 7.5
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm
20 DSR 19.15.1 cementm concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone 24.00 each 544.70 13072.80
aggregate 20 mm nominal size) as per standard design :
TOTAL COST OF EX. DRAINAGE 302773.60 0.00
Digitally signed by ARUN
PROPOSED CONTRACTION OF COMPOSITE REGIONAL CENTRE(CRC) AT JAMDOLI
(COST OF EXTERNAL RAIN WATER HARVESTING WORKS)
S.N. SOR./MR. DESCRIPTION QTY. UNIT AMOUNT(Rs
(in Rs) AMOUNT(Rs)
I RAIN WATER HARVESTING
1 Earth work in excavation by mechanical
means (Hydraulic excavator)/manual means
over areas (exceeding 30 cm in depth, 1.5 m
in width as well as 10 sqm on plan) including
getting out and disposal of excavated earth
lead upto 50 m and lift upto 1.5 m, as
directed by Engineer-in-charge.
(A) D.S.R 2.6.1 All kinds of soil 22.59 Cum 177.50 4009.66
Extra for every additional lift of 1.5 m or part
(B) D.S.R 2.6.1+2.26.1 thereof in excavation / banking excavated or 22.59 Cum 304.30 6874.02
stacked materials.
(C) 2.6.1+2.26.1 In all kind of soil upto 3.0m to 4.5m. depth
(D) 2.6.1+2.26.1 In all kind of soil upto 4.5 m to 6.0m. depth 10.54 Cum 659.30
2 Providing and laying in position cement
concrete of specified grade excluding the cost
of centering and shuttering - All work up to
1:2:4 (1 cement : 2 coarse sand (zone-III) :
4 graded stoneaggregate 20 mm nominal 1.20 Cum 7878.50 9448.00
D.S.R 4.1.3A size)
3 Brick work with common burnt clay F.P.S.
(non modular) bricks of class designation 7.5
in foundation and plinth in:
Cement mortar 1:4 (1 cement : 4 coarse
D.S.R 6.1.1 sand)
4 Providing and laying in position cement
concrete of specified grade excluding the cost
of centering and shuttering - All work up to
1:1½:3 (1 Cement: 1½ coarse sand (zone-
III) : 3 graded stone aggregate 20 mm 1.61 Cum 8340.85 13445.43
D.S.R 4.1.2 nominal size)
5 Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in
position and binding all complete upto plinth
Thermo-Mechanically Treated bars of grade Fe-
D.S.R 5.22.6 500D or more.
6 12 mm cement plaster of mix :
7 5.9 Centering and shuttering including strutting,
propping etc. and remova of form for :
5.9.1 Foundations, footings, bases of columns, etc.
D.S.R for mass concrete
5.9.2 Walls (any thickness) including attached
pilasters, butteresses, plinth and string Sqm 842.50 0.00
D.S.R courses etc.
5.9.3 Suspended floors, roofs, landings, balconies
and access platform 10.75 Sqm 927.25 9964.83
Providing M.S. foot rests including fixing in
manoholes with 20x20x10 cm cement
8 DSR 19.15 concrete blocks 1:3:6 (1cement : 3 coarse
sand : 6 graded stone aggregate 20mm
nominal size) as per standard design:
DSR 19.15.1 With 20x20mm square bar 10.00 Nos. 544.70 5447.00
9 Providing and fixing in position precast RCC
manhole cover and frame of required shape
and approved quality.
M.D. -10- Circular shape 500mm internal
DSR 19.19.2.2 diameter
10 Boring/drilling bore well of required dia for
casing/ strainer pipe, by suitable method
prescribed in IS: 2800 (part I), including
collecting samples from different strata,
preparing and submitting strata chart/ bore
log, including hire & running charges of all
equipments, tools, plants & machineries
required for the job, all complete as per
direction of Engineer -in-charge, beyond 90
metre & upto 150 metre depth below ground
DSR 23.2 level.
DSR 23.2.1.1 Drilling of 300mm dia bore hole manually. 150.00 MTR 825.70 123855.00
Digitally signed by ARUN
Supplying, assembling, lowering and fixing in
vertical position in bore well unplasticized PVC
medium well screen (RMS) pipes with ribs,
conforming to IS: 12818, including hire &
labour charges, fittings & accessories etc. all
complete, for all depths, as per direction of
Engineer-in-charge.
DSR 23.4.2 150 mm nominal size dia 100.00 MTR 681.90 68190.00
Supplying, filling, spreading & leveling stone
boulders of size range 5 cm to 20 cm, in
12 DSR 23.5 recharge pit, in the required thickness, for all 12.13 cum 1509.80 18313.87
leads & lifts, all complete as per direction of
Engineer-in-charge.
13 Supplying, filling, spreading & leveling gravels
of size range 5 mm to 10 mm, in the recharge
pit, over the existing layer of boulders, in
required thickness, for all leads & lifts, all
complete as per direction
DSR 23.6 of Engineer-in-charge.
14 Supplying, filling, spreading & leveling coarse
sand of size range 1.5 mm to 2 mm in
recharge pit, in required thickness over gravel
layer, for all leads & lifts, all complete as per
direction of Engineer -incharge.
15 Gravel packing in tubewell construction in
accordance with IS: 4097, including providing
gravel fine/ medium/ coarse, in required
grading & sizes as per actual requirement, all
complete as per direction of Engineer-in-
DSR 23.8 charge.
DESILTING CHAMBER
16 Earth work in excavation by mechanical
means (Hydraulic excavator)/manual means
over areas (exceeding 30 cm in depth, 1.5 m
in width as well as 10 sqm on plan) including
getting out and disposal of excavated earth
lead upto 50 m and lift upto 1.5 m, as
directed by Engineer-in-charge.
D.S.R 2.6.1 All kinds of soil 10.05 Cum 177.50 1784.00
17 2.6.1+2.26.1 Extra for every additional lift of 1.5 m or part
thereof in excavation / banking excavated or 4.06 Cum 304.30 1235.80
D.S.R stacked materials.
18 Providing and laying in position cement
concrete of specified grade excluding the cost
of centering and shuttering - All work up to
1:2:4 (1 cement : 2 coarse sand (zone-III) :
4 graded stoneaggregate 20 mm nominal 1.04 Cum 7878.50 8184.03
D.S.R 4.1.3 size)
19 Brick work with common burnt clay F.P.S.
(non modular) bricks of class designation 7.5
in foundation and plinth in:
Cement mortar 1:4 (1 cement : 4 coarse
D.S.R 6.1.1 sand)
20 Providing and laying in position cement
concrete of specified grade excluding the cost
of centering and shuttering - All work up to
1:1½:3 (1 Cement: 1½ coarse sand (zone-
III) : 3 graded stone aggregate 20 mm 1.38 Cum 8340.85 11541.90
D.S.R 4.1.2 nominal size)
21 Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in
position and binding all complete upto plinth
Thermo-Mechanically Treated bars of grade Fe-
D.S.R 5.22.6 500D or more.
22 12 mm cement plaster of mix :
D.S.R 13.4.1 1:4 (1 cement: 4 coarse sand) 17.36 Sqm 357.25 6201.86
23 5.9 Centering and shuttering including strutting,
propping etc. and remova of form for :
5.9.1 Foundations, footings, bases of columns, etc.
D.S.R for mass concrete
5.9.2 Walls (any thickness) including attached
pilasters, butteresses, plinth and string 1.50 Sqm 842.50 1263.75
D.S.R courses etc.
5.9.3 Suspended floors, roofs, landings, balconies 6.93 Sqm 927.25
and access platform
24 Providing M.S. foot rests including fixing in
manoholes with 20x20x10 cm cement
concrete blocks 1:3:6 (1cement : 3 coarse
sand : 6 graded stone aggregate 20mm
DSR 19.15 nominal size) as per standard design:
DSR 19.15.1 With 20x20mm square bar 12.00 Nos. 544.70 6536.40
25 Providing and fixing in position precast RCC
manhole cover and frame of required shape
and approved quality.
M.D. -10- Circular shape 500mm internal
Total ITEMS 608397.03
Total ITEMS OF 2 HARVETING PITS 1216794.05
Digitally signed by ARUN
NAME OF PROJECT-PROPOSED COMPOSITE REGIONAL CENTRE(CRC) AT JAMDOLI ,AGRA ROAD ,JAIPUR
DETAILED ESTIMATE FOR BOREWELL/TUBEWELL
S. DSR RATE DSR AMOUNT DSR MR
DESCRIPTION UNIT QTY
No 2021 (in Rs.) (in Rs.) AMOUNT
BORE WELL INSTALLATIONS (As per D.S.R.2018)
1.0 23.1 Transportation of Rig Machine
23.1.1 All types of soil
23.1.2 Rocky strata including Boulders
2 Supplying, assembling, lowering and fixing in vertical
position in bore well, unplasticized PVC medium well casing
(RMS) pipe of required dia, conforming to IS: 12818,
including required hire and labour charges, fittings &
accessories etc. all complete, for all depths, as per direction
of Engineer -in-charge.
23.4.2 150mm nominal size dia metre 100 807.45 80745.00
3 `Gravel packing in tubewell construction in accordance with
IS: 4097, including providing gravel fine/ medium/ coarse, in
23.8 required grading & sizes as per actual requirement, all cum 5 2024.5 10122.50
complete as per direction of Engineer-in-charge.
Development of tube well in accordance with IS : 2800 (part
I) and IS: 11189, to establish maximum rate of usable water
yield without sand content (beyond permissible limit), with
required capacity air compressor, running the compressor
for required time till well is fully developed, measuring yield
of well by "V" notch method or any other approved method,
measuring static level & draw down etc. by step draw down
method, collecting water samples & getting tested in
approved laboratory, i/c disinfection of tubewell, all
complete, including hire & labour charges of air compressor,
tools & accessories etc., all as per requirement and direction
of Engineer-in-charge.
COST OF 1 BORE WELL 1,76,952.90
SECTION- VI BORE WELL INSTALLATIONS (NON-SCHEDULED ITEMS)
7 Supplying & Installation of suitable Hp submersible pump
B.S or K.S.B or equivalent make with finolex cable 1x3x2.5
squmm(upto 75mtr) withflexible conduit 25mm dia,
electrical out door pannel with required electrical fitting
such as MCB of 0-25Amp (Havell or Indocopp or MDS make),
Volt & Ampere meter (AE make), single phase preventer
(Minilac or VSP -1 make) starter (L&T or BCH make) etc of
approved make, 40mm HDPE Pipe (25 mtr) and all
accessories complete as per requirement of site.
a) Contractor shall include the rate of electrical control
panels complete with all accessories &controls, all
Electrical/Mechanical items as required to operate the
system automatic/manual.
b) Contractor to select suitable HP of pumps .
Digitally signed by ARUN
c) Level Controller with sufficient nos. of low / high level
alarms, contacts with electrodes and control wiring for the
automatic operation of water supply pumps, Submersible
Sump Pumps, to achieve the functional requirement shall be
provided. Control wiring between these pumps and water
tanks shall be provided.Domestic water pumps must start at
low water level in overhead domestic water tank & stop at
high level in that water tank. Dry running protection shall be
provided for all the pumps.Sequencing shall be provided for
each set of pumps.
COST OF 1 BORE WELL 26,160.25
COST OF 1 BORE WELL 2,03,113.15
Digitally signed by ARUN
Composite Regional Centre Jamdoli, Jaipur
BOQ with estimated rates for providing and fixing of CLAYTON T24 Extruded Hollow Clay / Terracotta Ventilated Rainscreen Façade Tiles :
S.MR Particulars Qty Unit Rate (Rs.) Amount (Rs.)
1 Providing and fixing of Extruded Hollow Clay / Terracotta
Ventilated Rainscreen Façade Tiles of grid dimensions 24 x 300 x
900 ~ 1200mm (c/c) in a horizontal direction on the building facade.
The extruded hollow clay tile cladding material shall be rigid and of
adequate strength and shall have a minimum total thickness of
24 mm (±10%). The tiles shall be installed using the
ventilated rainscreen principle, with provision for natural
ventilation of the space between the façade tiles and the
structural wall.
The clay tiles shall be of the hollow type, fixed to a supporting
aluminium framework (Alloy 6063 T6) consisting of vertical
'T'/ 'L'/ Tube sections measuring 80x60mm/ 40x60mm/
40x40mm respectively, spaced at maximum 1200mm c/c
intervals matching to the tile vertical grid, with intermediate
vertical members/ sections in the middle if required based
on the structural calculations, and horizontal aluminium 'C'-
clamps as per brand design and specifications fixed on top of
the verticals sections at middle/ intermediate points and
at tile joints, and at
corners/ wall ends, spaced at 300mm c/c vertically matching to the
tile horizontal grid.
The vertical 'T'/'L/Tube' sections shall be fixed to the MS
framework/ Brickwork/ Concrete using HDG Steel L-brackets
(Galvanized thickness minimum 80 microns) and AISI 304
stainless steel fasteners as applicable. The brackets shall be
fixed to the vertical aluminium T / L / Tube profiles using two AISI
304 stainless-steel nut & bolts M6 x 25mm / self-drilling screws
/ self-tapping of
dimensions 5.5 x 25mm.
The horizontal aluminium 'C'-clamps shall be fixed on top of the
vertical aluminium 'T'/'L/Tube' sections from front using two
AISI 304 stainless steel self-drilling/ self-tapping screws. The
tiles shall be mounted on the C-clamps with EPDM profiles in
between such that the tiles are supported at top and
bottom at both ends. The vertical and horizontal joints between
adjacent tiles to be a 10mm open groove. Dimensions and
actual spacings of all system components to be based on a
structural/ static calculation.
i. CRC Building
ii. Canteen and Store Building
iv. Boundary Wall
a) Colour : Peach or approved by Engineer in Charge 2,422.36 Sqmt 8,995.00 2,17,89,100.00
b) Colour : Natural Brick Terracotta or approved by Engineer in Charge
Mechanical Properties of the terracotta tiles :
Maximum / Minimum Values
Dimension Tolerances as per ISO 10545-2
Length (Extrusion Direction) : +/- 1 mm
Height : +/- 0.5%
Thickness : +/- 10%
Straightness (Extrusion Direction) : +/- 0.35% of length
Rectangularity : +/- 1% of height
Surface flatness : +/- 0.7% of length or height
Water absortion (Boiling Method) as per ISO 10545-3 : < 10%
Digitally signed by ARUN
Flexural/ Bending strength as per ISO 10545-4:
Sub-total 2,17,89,100.00
Digitally signed by ARUN
INTERIOR WORKS ON MR
Sr.No Description Unit QTY. Rate Amount
1 Providing and fixing of manual roller blinds with Blackout or Sunscreen fabric 5% or 10%. Control clutch drive unit engineered heavy duty chain Sqm 195 3,750.00 731250
drive pulley operating system consisting of gear clutch housing and locking plug containing 6 ribs and flexible to be inserted in 37mm or 50mm
Roller tube. It is self lubricating exclusive clutch with safety pins for secure bracket installation and unlocking pin for quick manual removal.
Universal clutch is most convenient for large windows down to the smallest windows. It shall be driven by a ball chain pulley with plastic ball
chain and can be universally positioned either Right hand or Left hand side of the shade. Clutch gear ratio 1.75:1for reduced operating force on
larger blinds. Tube bearing plug Idler: Exclusive self lubricating spring loaded plastic bearing end plug with positive locking wheel allows for
adjustment and provides for a secure installation and removal of shade. Tube bearing plug contains 6 ribs and flexible to be inserted in 37mm
or 50mm roller tube. Mounting Hardware Brackets: Universal brackets including end plug bracket with lock down retainer device. Brackets
finish of powder coated Aluminium installation brackets made of stamped and hardened steel with 46mm projection for wall, ceiling and side
fitting with screws and end cap covers. Valance Systems: Flat extruded valance alloy 6060 and temper T66 EN755 size of
5.6mm * 84.5mm and wall thickness 1.6mm with standard powder coat white finish. Valance systems protect and hide the front of the fabric on
the tube, creating a more sleek look. Roller Tube: Circular-shaped aluminium tube extruded from alloy 6060 and temper T66 – EN755 of 37mm
inside diameter and outside diameter 40.2mm extruded tube to have a 1.6mm wall thickness with standard anodized natural finish. Heavily
reinforced with minimum six internal ribs providing additional deflection strength and allows for secure placements of clutch and end plug.
Bottom Rail: Flat-shaped extruded aluminium from alloy 6060 and temper T66 – EN755 of dimension 13mm * 30mm and wall thickness of
1.5mm and weight more than 350g/m providing additional stability to avoid swaging and damage of shade fabric. Rail standard finish of
powder coat white colour and provided end cover.
Ball Chain: Shall be 2mm diameter cord with 4.5mm diameter acetal balls moulded coaxially to it on 11.8mm pitch to form an endless ball
chain. It is used for raising or lowering action of the shades. Plastic parts: All plastic components are UV-stable compounds available white
colour . Screen Fabric having Following Specification Composition: 24%PES+76%PVC Openness factor: Approx 5% Thickness: 0.56±5% mm
Weight per ㎡ :445 ±5% g/m2Weave: Basket Weave 2 x 1 Fire resistance: NFPA 701 Color fastness: AATCC16 Grade 4-5 Health/Safety certificate:
Oekotex /GreenGuard Blackout fabric having following specifications: Composition- 100% fiberglass with PVC coated or equivalent. washable
Openness factor- opaque Weight (gram/ sqm)- min 407 g/sqm Thickness- min 0.51 mm Fire Classification- NFPA-701 or equivalent Fastness to
2 light- 6-7/8and
Providing or fixing
higherofIndoor Air -Quality-
EcoSlats made outGreenGuard / Eco-Codice
of HDF fibreboards, Certified.
Chain Hole Pescribed System CHPS wooden grooved Sqm 900 7,860.00 7074000
Ecoslats (Colour Rubber Wood, Cherry Mahagony , Layon Walnut, Baverian Beech, Ice Beech, Coburg Oak) D8-2 -(2mm grooves @ 8mm centers)
/ D16-2 - (2mm EcoSlats @16mm pitch) / D32-2 - (2mm grooves @ 32mm centre) /D64-2 - (2mm grooves @ 64mm centre), backlined with
acoustical fleece, tongue-groove edge for a seamless look, of lineal dimension size 128mm / 192mm x 2440mm x 16.7mm thick having
density 800Kg /m3, weight 10 Kgs/m2, installed by using wall Panelling system. The NLF framework system shall include NLF CC25, fully
knurled, sectional thickness 0.55mm, length 3600mm, web 50mm, depth of 25mm and equal flanges 15mm is fastened to the wall positioned
horizontally/vertically at every 600mm centres. NLF CC18,aluminium core cross channel, thickness 0.5mm, length 2400mm, web 15mm &
27mm, depth 18mm and flanges of 7mm with suitable edge & center brackets is then fixed perpendicular to the Channel CC25 with the help of
fasteners at every 400mm centers . NLF Ecoslats of size 128mm / 192mm x 2440mm x 16.7mm in then fixed perpendicular to Channel CC18 with
suitable edge & centre brackets. Contractor to provide expansion joints of 3mm at every 4.88m length wise and 4.992m width wise. The system
is backlined with Anutone SynthPF 50mm thicnkess with 1500 gsm of poly fibre base material insullation adhered on wall with dab
spots. Fibreboard• Acoustics – NRC up to 0.75• Climate (OC RH) – 50, 70• Light reflectance – 75%• Green (RC %) – 25• Hygiene (VoC, Clean
room) – Low, Class 1• Strength, Load capacity (Kg) - Antisag, Ball-Impact .
3 U Baffle Ceiling System 50 x 100 in 200mm Module Sqm 1500.00 5,860.00 8790000
U Baffle Aluminium plain panel ceiling manufactured by of white colour consisting of panel size 100 mm deep X 50 mm width using 0.60 mm
thick, panel length upto 6.0 mtr. The Baffle shall be rollformed. Coil Coated on a Continuous Paint Line, Double baked and roll formed from
enamelled corrosion resistance Aluminium alloy AA 3105 (Al. Mg) for higher strength and good roll forming characteristics. Panels shall be
clipped to a baked enamelled Aluminium carrier of 30 mm wide x 47 mm high x 0.5 mm thick, Black Colour coated, one leg of the carriers with
cut outs to hold the panels in a module of 200
mm. Panel carrier shall be suspended by means of threaded rod at a distance of 1.20 mtr c/c.Paint Finish: Aluminium panels shall be
chromatised for maximum bond between metal and paint enamelled twice under high temperature, Exposed side with a full primer and finish
coat on a Continuous Paint Line.Ceiling Finish above U Baffle Ceiling : Ceiling area above U Baffle to be painted in black colour before fixing this
system Mode of Measurements: Measurements shall be wall to wall without any deductions for lights, diffuses, columns etc.Make in India: The
manufacturer should have manufacturing plant in India to the promote make in India products as per the latest directives of Government of
India. High Precision High Speed Cold Roll Forming : The panels shall be manufactured on high precision & high speed roll forming machine to
control product diamensional tolerance within limits and achieve consitent quality product.Experience : The manufacturer should have
minimum experience of 7 years in similar product manufacturing pplication in India.Quality Management System : The company should have
own Manufacturing Plant with QC Laboratory.ISO Certification - ISO 9001: 2015 Quality Management System Certification shall be
mandatory.Sustainability: Green Building Certification / The manufacturer should be able to submit 'IGBC GreenPro Certificate' for the product
proposed for green building certification.Fire Rating : Product should comply with per BS 476 Part 6 & Part 7.Approved
4 Supply & Installation of Plain/Perfo torsion spring Tile Ceiling System white colour comprising of Tile of 600mm wide and 600mm long Sqm 230.94 3,860.00 891428.4
manufactured out of 0.5mm thick Galvanized steel. The metal ceiling panels shall be downward accessible with a minimum of four (4) torsion
springs per panel. The Tile will be manufactured on advanced CAD/CAM equipment that includes several levelling stages in the manufacturing
process. Torsion Spring panel with two side legs die formed and two end legs die formed and punched to receive torsion springs (min two
springs each end or side) for secure engagement into Tee Grid main runners which are factory punched to receive torsion springs. Tiles will
be square edged. The metal ceiling panels shall be downward accessible with a minimum of four (4) torsion springs per panel. The Tile
shall be Polyester powder coated in wooden finish colour.Main Runners: 24mm deep, inverted “Tee” sections, 3.6m long, with factory
punched flanges to receive torsion spring assembly. Main Tee on center spacing to match panel length.Cross Runners: 24 mm deep, inverted
“Tee” sections designed to interlock in to web of main tee section on designated spacing. Cross tee length to match panel length. Cross tees are
spaced spacing 1200mm on center maximum.Suspension System: As per manufacturer standard considering type of plenum and its height.Paint
finish –The panels will be pre treated in latest nano technology process and electro statically powder coated with automatic Carona system
and cured with gas catalytic technology.Mode of Measurements: Measurements shall be wall to wall without any deductions for lights,
diffusers, columns
5 Providing and fixing tactile flooring tiles — Supplying, laying, and fixing factory-made, pre-moulded tactile paving tiles of approved brand, Sqm 250 400 100000
conforming to IS 13801:2013 (or latest), made of vitrified ceramic/UV-stabilised polyurethane or equivalent, in approved colour and pattern as
per site requirement, having raised directional or warning profiles to assist visually impaired persons in wayfinding and hazard identification.
Tiles shall be non-slip, weather-resistant, UV-resistant, impact-resistant, and suitable for heavy pedestrian traffic. The surface shall have high
abrasion resistance (minimum MOH hardness 6) and shall retain tactile and visual contrast for the product’s life cycle.
The tactile tiles shall be fixed over a base of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) or adhesive bed (for indoor applications)
laid true to line and level, with proper joints not exceeding 3 mm width. Joints shall be filled with white cement slurry mixed with approved
pigment to match the tile shade. For outdoor installations, the bedding shall be over a compacted sub-base with adequate slope for drainage.
The work includes cutting, finishing, alignment, curing, and cleaning of the finished surface, ensuring continuity of tactile guidance as per
Harmonised Guidelines and Standards for Universal Accessibility in India 2021 and CPWD Specifications. All complete as directed by the
Engineer-in-Charge.
6 Providing and fixing Braille Signages made of high-grade anodized aluminium (min. 2 mm thick) / stainless steel (min. 1.5 mm thick) / acrylic Nos. 75 1500 112500
(min. 3 mm thick), corrosion-resistant, UV-stabilised, and with a smooth, non-glare finish. Signages shall have raised tactile characters and
pictograms (min. 16 mm height, raised 0.8–1.5 mm) as per ISO 7001 and NBC/Harmonised Guidelines 2021, with embossed Braille text (Grade
1/2 English/Hindi as specified) of standard cell dimensions. Background and characters shall have a minimum 70% visual contrast, with fade-
resistant colours. Signages to be installed at 1400–1600 mm above FFL on walls/doors or approved surfaces using SS screws/adhesive, with
edges rounded/chamfered. Work includes preparation of shop drawings, transportation, installation, labour, materials, and incidental works,
complying with ISO 21542, NBC 2016 (Part 3), and Harmonised Guidelines for Universal Accessibility 2021, complete in all respects as directed
by the Engineer-in-Charge. SUB TOTAL 17699178.4
Digitally signed by ARUN
Cover Two BOQ Summary
BOQ Summary Details
Department Name : NBCC India Limited
Tender Number NBCC/SrED/RBG/Rajasthan/CRC/NIT/25-26/5-dated-15-09-
Description Construction of Permanent building of Composite Regional
centre (CRC) including Civil,Electrical , Plumbing and others
Internal and External services at Jamdoli,Agra Road,Jaipur
Sheet Name SL NO Bidder Company / Total Amount Total Amount In Rank
Individual Name Words
BOQ Quote Sheet 1 M/S. Gamut 18,19,57,777 Eighteen Crore L1
Buildcon Private Nineteen Lakh Fifty
Limited Seven Thousand
2 TRILOK AND 18,53,11,499 Eighteen Crore Fifty L2
ASSOCIATES Three Lakh Eleven
Hundred Ninety Nine
3 Vee Kay 19,33,89,808 Nineteen Crore Thirty L3
Constructions Three Lakh Eighty
Nine Thousand Eight
4 PARAKH 19,34,14,288 Nineteen Crore Thirty L4
ASSOCIATES LLP Four Lakh Fourteen
Hundred Eighty Eight
5 KRISHNA 19,38,79,402 Nineteen Crore Thirty L5
CONSTRUCTION Eight Lakh Seventy
CO Nine Thousand Four
6 CITY PRIDE 19,40,99,720 Nineteen Crore Forty L6
BUILDCON Lakh Ninety Nine
PRIVATE LIMITED Thousand Seven
7 A.K. Builders 19,45,40,355 Nineteen Crore Forty L7
Five Lakh Forty
Hundred Fifty Five
Sheet Name SL NO Bidder Company / Total Amount Total Amount In Rank
Individual Name Words
8 YSM BUILDCON 19,54,70,584 Nineteen Crore Fifty L8
PRIVATE LIMITED Four Lakh Seventy
Hundred Eighty Four
9 KCC INFRA PVT 19,63,02,895 Nineteen Crore Sixty L9
LTD Three Lakh Two
Hundred Ninety Five
10 JAISHIVA INFRA 19,81,87,834 Nineteen Crore Eighty L10
PROJECTS One Lakh Eighty
PRIVATE LIMITED Seven Thousand
Eight Hundred Thirty
Four Rupees Only
11 HARI NARAYAN 19,97,30,056 Nineteen Crore Ninety L11
KHANDELWAL Seven Lakh Thirty
Thousand Fifty Six
12 LAKHLAN 20,07,33,725 Twenty Crore Seven L12
CONSTRUCTION Lakh Thirty Three
CO Thousand Seven
Hundred Twenty Five
13 NACDAC 20,07,33,725 Twenty Crore Seven L12
INFRASTRUCTUR Lakh Thirty Three
E LIMITED Thousand Seven
Hundred Twenty Five
14 WONTEL 20,27,90,021 Twenty Crore Twenty L13
TECHNOLOGIES Seven Lakh Ninety
PRIVATE LIMITED Thousand Twenty
One Rupees Only
15 Quazar 20,29,36,900 Twenty Crore Twenty L14
Infrastructure Pvt Nine Lakh Thirty Six
Ltd Thousand Nine
16 SSP PROMOTERS 20,44,79,122 Twenty Crore Forty L15
& BUILDERS Four Lakh Seventy
PRIVATE LIMITED Nine Thousand One
Hundred Twenty Two
17 RAMESH KUMAR 20,57,76,548 Twenty Crore Fifty L16
BANSAL Seven Lakh Seventy
CONTRACTOR Six Thousand Five
Hundred Forty Eight
18 MAHESH CHAND 20,59,23,426 Twenty Crore Fifty L17
GUPTA Nine Lakh Twenty
Three Thousand Four
Hundred Twenty Six
Sheet Name SL NO Bidder Company / Total Amount Total Amount In Rank
Individual Name Words
19 M/s JYOTI SARUP 20,83,46,918 Twenty Crore Eighty L18
MITTAL Three Lakh Forty Six
Hundred Eighteen
20 SGB INFRA 21,02,80,816 Twenty One Crore L19
LIMITED Two Lakh Eighty
Hundred Sixteen
21 NK GUPTA 21,23,37,113 Twenty One Crore L20
Twenty Three Lakh
Hundred Thirteen
22 SUNRISE 21,34,87,660 Twenty One Crore L21
INFRABUILD Thirty Four Lakh
PRIVATE LIMITED Eighty Seven
23 EVERCREST 21,85,79,442 Twenty One Crore L22
PROJECTSPRIVAT Eighty Five Lakh
E LIMITED Seventy Nine
Hundred Forty Two
24 MITTAL 22,03,17,503 Twenty Two Crore L23
CONSTRUCTION Three Lakh
COMPANY Seventeen Thousand
Five Hundred Three
25 BIHANI 24,01,70,558 Twenty Four Crore L24
CONSTRUCTIONS One Lakh Seventy
PRIVATE LIMITED Thousand Five
Hundred Fifty Eight
aoc.pdf
Download all tender documents and submit your bid