Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹37.9 L+₹2.0 L (5.69%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹38.0 L+₹2.2 L (6.12%)Rejected-Finance 41B 1H JAYANTIPUR PREETAM NAGAR ALLAHABAD | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹38.5 L+₹2.6 L (7.34%)Rejected-Finance 83 5M 1 SHIV GANGA PURAM YADAVPUR ROAD UMARPUR NEEWAN PRAYAGRAJ 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹38.6 L+₹2.8 L (7.70%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
13 Mar 2023, 6:00 pmClosed
GE (AF) Bamrauli
GE (AF) Bamrauli
SPECIAL REPAIRS TO POWER SUPPLY IN FRASTRUCTURE FOR AFNET POWER HOUSE AND SE(L) UNDER GE (AF) BAMRAULI
2023_MES_582306_1
8773/E8
Open Tender
Civil Works
Works
180 days
GE (AF) Bamrauli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Bamrauli
₹76,000
31 Mar 2023
22 Feb 2023
20 Mar 2023
22 Feb 2023
13 Mar 2023
8 Mar 2023
Amount
Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 Sqmm 3.5 Core laid in trenches/ducts/along poles/ through pipe under road etc all as specified and directed by Engr-in-Charge
Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 Core laid in trenches/ducts/along poles/ through pipe under road etc all as specified and directed by Engr-in-Charge
Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 Core aid in trenches/ducts/along poles/ through pipe under road etc all as specified and directed by Engr-in-Charge
Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 Core laid in trenches/ducts/along poles/ through pipe under road etc all as specified and directed by Engr-in-Charge
Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 Core laid in trenches/ducts/along poles/ through pipe under road etc all as specified and directed by Engr-in-Charge
Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 Corel aid in trenches/ducts/along poles/ through pipe under road etc all as specified and directed by Engr-in-Charge
Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 Core laid in trenches/ducts/along poles/ through pipe under road etc all as specified and directed by Engr-in-Charge
Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 Core laid in trenches/ducts/along poles/ through pipe under road etc all as specified and directed by Engr-in-Charge
Supply and fix in replacement of ON LOAD Change over switch 415 V in sheet metal enclosure 4 Pole of capacity 400 Amps all as specified and directed by Engr-in-charge
Excavation in trenches not exceding 1.5m wide and noe exceding 1.0 sq m on plan and not exceding 1.5m depth and getting out soft soil all as specified and directed
Returing filling in including spreading leveling watering and well ramming in layer not exceding 25 cm as in soil all as specified and dirceted all as specified and directed
Removing excavated material not exceding 50 m and depostingwhere directed at a level not exceding 1.5 m above the starting pointall as specified and directed
M & L for sand cushioning all around the cable for protection by natural sand all as specified and directed
Supplying and Laying old size bricks of size 230mm x 113 mm x 75 mm for cable protection all as specified and directed
Supply and Laying in trenches for road/plinth and fixing alongwith pole/wall GI Tube 80 mm light grade for protection of cable all as specified and directed
Supply and Laying in trenches for road/plinth and fixing alongwith pole/wall GI Tube 50 mm light grade for protection of cable all as specified and directed
Supply and Laying in trenches for road/plinth and fixing alongwith pole/wall GI Tube 40 mm light grade for protection of cable all as specified and directed
M & L for boring holes (manually) under road, hard standing without damaging surface for 80/50/40 mm dia GI pipe etc complete all as specified and directed
Taking down carefully aluminium batten point, wiring for light/fan/socket/bell or power point including. All fittings i.e. switch, sockets, ceiling rose, regulators, batten holders, etc. Complete and making good disturbed surfaces of wall/floor to match with the surroundings of wall/ceiling/floor etc including taking down old light fittings. Note :- (i) Contractors quoted rate of this item deemed inclusive of unscrewing of the serviceable fittings and fixture as directed and deposit in MES store yard. (ii) Quoted rate also deem to be included cost of cutting chases for taking out concealed conduit and nitch for terminal box. (iii) Decision of GE shall be final and binding in respect of serviceability of fittings/fixture.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLSH cable 1100 volts grade with multi stranded copper conductor drawn through new PVC concealed conduit mediem grade, ISI marked and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded modular metal flush box duly make embossed, concealed in walls with suitable modular inner and outer plate for housing switches , socket outlet and fan regulators etc, complete all as specified and as directed for the followings:-
(a) One light/fan/bellpoint controlled by one switch single pole one way
(b) All as per item No 20 here-in-before but one 3 pin 6 amp switch socket out let independent .
(c) All as per item No 20 here inbefore but one 3 pin 6 amps socket outlet on the same board with other switch complete .
All as per item No 20 here-in-before but using 02 Nos. 4.0 sq mm size for main cable and 01 No.4 sq mm size as earth conductor for one 16 Amp switch socket outlet on independent board.
Supply and fix switch modular flush 6A single pole one way ISI marked
Supply and fix modular sockets 6 Amp 2 in 1 2/3 pin combined all as specified and directed.
Supply and fix switch modular flush type 15/16 Amp single pole one way 240 volt one module ISI marked
Supply and fix modular sockets 16 Amp 2 in 1 3/5 pin combined all as specified and directed.
Supply and fix ceiling rose surface bakelite 60x25mm three terminal
Supply and fix electronic step type fan regulator 240 volt 50 Htz 120 watt (switch/sockets type in shape) modular type
Supply & fix MCB DB SPN 12 way, double door, IP-43, IK-09, Isolated Neutral Bar and fixed flush to wall and suitable for universal mounting complete all as specified and directed.
Supply & fix MCB DB SPN 8 way, double door, IP-43, IK-09, Isolated Neutral Bar and fixed flush to wall and suitable for universal mounting complete all as specified and directed.
Supply & fix MCB DB SPN 4 way, double door, IP-43, IK-09, Isolated Neutral Bar and fixed flush to wall and suitable for universal mounting complete all as specified and directed.
Supply and fix MCB, single pole and neutral, 230 volts, 40 to 63 Amp rating, 'C' series fixed in DBs catered here-in-before.
Supply and fix MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge
S&F Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 1.5 sqmm FRLS, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 1.5 sqmm FRLSH 1100 volts grade cable continuous earth wire of green colour code complete. Note:- (a) Two runs of 1.5 sqmm cable and one run of 1.5 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.
S&F Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 4 sqmm FRLS, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 4 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete. Note:- (a) Two runs of 4 sqmm cable and one run of 4 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.
S&F Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 6 sqmm FRLS, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 6 sqmm FRLSH 1100 volts grade cable continuous earth wire of green colour code complete. Note:- (a) Two runs of 6 sqmm cable and one run of 6 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.
S&F Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 10 sqmm FRLS, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 10 sqmm FRLSH 1100 volts grade cable continuous earth wire of green colour code complete. Note:- (a) Two runs of 10 sqmm cable and one run of10 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.
Supply and fix LED 2 X 2 ft backlite surface mounted fitting 36/40 Watts not less than 3200lm with Metallic CRCA powder coated body with high efficiency opal/PMMA diffuser with system efficacy > 80 lm/W, CRI>80, color temperature >5700k, IP 20, Power factor<0.95, THD<10%, 50000 burning hours , Ambient temperature 0 to 500 DegC, Driver should meet IEC complaint for safety, with voltage variation range of 150-270 V and surge protection of 2.5 KV including necessary fixing arrangementsfixed complete all as specified and directed.
Supply and fix in repair LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, > 2200 systems lumen outputwith lifetime of 50000 burning including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply and fix in repair LED batten luminaire surface mounted, 2 feet system wattage of 10 Watts, > 1000 systems lumen outputwith lifetime of 50000 burning including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply and fixing ceiling fans Robust and reliable inverter motor (brush less DC Motor) powered by ECM technology, BEE 5 star rating for energy saving, AC single phase 230/240 V of size 1200 mm sweep including making connection with three core flexible, copper cable pvc insulated of suitable length incl taking down old & deposited to MES store yard complete all as spd & directed. Note : Cost of remote cell included in this item
S&F Fresh air fan, single phase 230 volts of size 250 mm sweep, plastic body with louvers and making of hole & grouting nut & bolts and connecting with 3 run of 1.5 sqm, multicore, PVC insulated copper cable from ceiling rose and making good the disturbed surface with existing colour matching complete.
Supply & fix in repair factory made epoxy powder coated Load line Distribution Board TPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including insulated 200 Amp copper bus bar, Isolated neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 100 Amp as incomer and 6 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623.
Supply and fix in repair MCCB 160 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
Supply and fix in repair MCCB 100 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
Supply and fix wall mounted fan 400mm, 230 volts , 50 Hz 1420 RPM with 90 degree oscillation and having speed control by two pull cord system all as specified and directed.
S & F sheet metal enclosure with socket and plug top and MCB single pole and neutral enclosure with two Pin and earth plug and socket complete with one single pole MCB, 240 V, 20 Amp.
Supply & fix 35W LED building security light fitting including provision of 40mm bore GI light grade pipe1.2 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole/ wall complete all as specified and directed.
Supply and fix in replcement flood light 50 watt 240 volt 50 Htz 3000/6500K 120 lumen/watt IP-65 protection complete all as spd and directed.
M & L for preparing newly plastered surface and apply a coat of 1.5/2 mm thick wall care putty for making smooth surface and applying two coats of distemper oil emusion over coat of primer on surface of walls
M&L for Cutting the existing wall/removing existing steel bar to make a hole for fixing of exhaust fan through packing of wooden ply to support the ventilating/ air circulating fan including necessary nut and bolts of suitable size incl making good of disturbed surface complete all as directed by Engr-in charge.
M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron wire 4mm dia as earth lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No. 3, MES SSR Part I- 2009 with 15 mm dia medium grade GI pipe as a protection to earthing lead and 20 mm dia medium grade GI pipe for watering purpose including excavation & earth work in any type of soil, funnel, wire mesh, RCC pit with cover, cast iron frame complete and connected to earthing test point all as specified or indicated including testing on completion. Notes (i) The concrete pit shall be PCC (1:3:6) type C-1, 40mm thick precast cover slab of RCC with suitable Mild steel handle in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I (ii) PCC pit shall be provide at least 500 mm away from the earth pit and not on just on the eath pit and extra cost of additional length of water pipes and fittings junction etc shall be deemed to be included in the rate. (iii) Item includes the cost of 7.5 metre earth lead wire and GI pipe for protection of earth wire. Any varriation in quantity shall be adjusted.
S & F of exhaust fan 300/230 mm (Metal body) sweep complete with louvers including connecting with suitable size of copper conductor from ceiling rose to fan complete all as specified and directed.
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material.
K R GUPTA AND SONS
Bharat Trading Company
chauhan construction
M/S SATISH KUMAR
M/S SS Tarders
M/S SWASTIK BUILDERS
Avion Industries
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .