RequiredExperience with Government
RequiredAnnual Turnover
RequiredCertificate (Requested in ATC)
RequiredOEM Authorization Certificate
RequiredOEM Annual Turnover Bid to RA enabled Yes Note: 1. OEM Turn Over Criteria: The minimum average annual financial turnover of the OEM of the offered product during the last three years
Requiredending on 31st March of the previous financial year
Requiredshould be as indicated in the bid document. Documentary evidence in the form of certified Audited Balance Sheets of relevant periods or a certificate from the Chartered Accountant/Cost Accountant indicating the turnover details for the relevant period shall be uploaded with the bid. In case the date of constitution/incorporation of the OEM is less than 3 year old
Requiredthe average turnover in respect of the completed financial years after the date of constitution shall be taken into account for this criteria. Ophthalmic Operating Microscopes ( 1 pieces ) Technical Specifications 1/7 * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Standards Certifications for product - * Certification no and date - * Confirmity to Manufacturing Standards ISO 9001 & ISO 13485 ISO 9001 & ISO 13485 Performance Parameter Purpose It is used to see high contrast and detailed imaging of all regions of the human eye with the help of an apochromatic lens (or apo) which provide high light transmission
Requiredpermitting high-quality imaging at lower light intensities. It is used to see high contrast and detailed imaging of all regions of the human eye with the help of an apochromatic lens (or apo) which provide high light transmission
Requiredpermitting high-quality imaging at lower light intensities. Suitability for type of surgery Anterior Anterior Ophthalmic microscope should have apochromatic optics Yes * Mode of Magnification Motorized continuous magnification Motorized continuous magnification Magnification factor 04x
Required0.6x
Required1.0x
Required1.6x and 2.5x for 5 step 0.4 to 2.4 for continuous magnification
Required04x
Required0.6x
Required1.0x
Required1.6x and 2.5x for 5 step Eye piece 10 X 10 X Range of refractive power for the eyepiece in diopter - 8 to + 8 * Motorized foot control Yes (With XY Coupling) Yes (With XY Coupling) Waterproof foot control panel Yes * Functions of foot control Multi-function foot switch for various functions Multi-function foot switch for various functions
RequiredMulti- function programmable foot switch for various functions
RequiredOn-off
RequiredIntensity control and illumination functions 2/7 Foot switch Wired (with 3m or more cable) Wired (with 3m or more cable) Availability of red reflux switching in out facility Yes Yes
RequiredNo Binocular tube 0-180 degree inclined binocular tube with converging options 0-180 degree inclined binocular tube with converging options Inverted tube Yes Yes Image inverting integrated in Binocular tube Yes Yes
RequiredNo Type illumination for unique recognition Co-axial Co-axial Type of illumination LED LED Integrated Blue Barrier Yes * Adaptable for Assistant microscope Yes Yes
RequiredNo Adaptability for Assistant microscope with stereo co- observation tube with beam splitter in microscope body for addition stereo co- observation attachmen t/documentation to be supplied with external 50:50 beam splitter * Assistant microscope with stereo co axial co observation tube with beam splitter(80:20)/70:30 in the microscope body for additional stereo co observation attachment documentation to be supplied Yes
Requiredwith external 50:50 beam splitter Yes
Requiredwith external 80:20 beam splitter
RequiredYes
Requiredwith external 70:30 beam splitter
RequiredYes
Requiredwith external 50:50 beam splitter
RequiredYes
Requiredwith integrated beam splitter
RequiredNot supplied Stand by bulb change and failed bulb replacement Tool free design for stand by bulb change and for failed bulb replacement(Applicable for halogen & Xenon) Tool free design for stand by bulb change and for failed bulb replacement(Applicable for halogen & Xenon) Backup LED illumination integrated in system No (for Halogen & Xenon) Yes
RequiredNo (for Halogen & Xenon) 3/7 Should have heat absorbing and UV Filters
Requiredretina protection device and contrast enhancement aperture Yes * Floor stand Rust free floor standing type with fiber wheels with brake * Type of floor stand Programmable with magnetic brakes & clutches Programmable with magnetic brakes & clutches Width/Diameter of the base of floor stand in mm 700-850 700-850
Required851-1000 Maximum arm extension in mm more than 800 more than 800
Requiredmore than 1000
Requiredmore than 1200 The type of illumination of stand Halogen Xenon
RequiredHalogen
RequiredLED Power Supply sources 230 v 50 hz single phase * Online UPS provided Yes Yes Backup power time for UPS in minute 30 30 Comprehensive Warranty in years for complete equipment which shall be from the date of handing over of equipment to consignee 5 5 Operating temperature & humidity 10 - 40 degree centigrade and humidity of 15-90% * Dimensions Parameter The working distance of objective lens F supplied in mm 200 200 XY Coupling size 40 x 40 * IPD adjustment range in mm 55 x75 * Range of magnification 3x to 20x * Minimum load carrying capacity of stand in kg 8 * Size of machine (L xWxH) in mm x mm x mm - * 4/7 Weight of machine in kg 96 * Accessories Parameter One set of Sterilizable rubber caps for all knobs and dust cover to be supplied Yes * Main cable with power socket of standard indian make to be provided Yes * Miscellaneous Parameters Original User Technical manuals to be supplied in English in hard and soft copy Yes * Original copy of operating and service manuals to be supplied in English in hard and soft copy Yes * Installation
RequiredDemonstration and training to be provided at consignee end at any part of country Yes * The Principal Manufacturer Must Have Direct Presence/approved service center In India Yes * Availabilty of toll free facility for technical support maintened by OEM or authorized agencies Yes * Copies of certifications to be furnished to buyer on demand after placement of order Yes * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer. Additional Specification Documents