Er. Chander Shekhar
Office of the Executive Engineer, Electrical Division No. 3 Sector-4, Chandigarh.
MTC. OF E.I. IN NRB AT CHANDIGARH (DNIT FOR PROVIDING AMC OF EXISTING FIRE EQUIPMENT SYSTEM FROM COURT ROOM NO.1 TO 58 AND VARIOUS ADJOINING ROOMS AND BRANCHES ETC. IN PUNJAB AND HARYANA HIGH COURT, SECTOR-1, CHANDIGARH). (FOR THE YEAR 2026-27).
2026_CHD_92931_1
E3/47W/46
Open Tender
Electrical Works
Percentage
365 days
Chandigarh
as per NIT
2 documents required · 2 mandatory
₹0
₹28,900
4 Aug 2026
2 Jun 2026
9 Jun 2026
2 Jun 2026
9 Jun 2026
2 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Servicing &Mtc. of Fire Alarm detection system . Honeywell- Esser make (FACP) fire alarm control panel with notifier make PA system alongwith cable/ wires network in Punjab and Haryana High Court Sector-1, Chandigarh. The details of fire alarm system is as under:- | |||||
| 1.01 | Main FACP Microprocessor based with minimum 10 loop capacity with 20% spare capacity, having 100% Hot Redundant Intelligent Addressable Fire alarm Panel (In case panel do not have redundancy, vendor needs to supply 100% spare programmed mother board, spare loop cards and network cards for every panel. If vendor is providing more than one panels, than all panel shall be networked peer to peer),with minimum 200 character LCD display & onboard TCP/IP port/External I.P port to access panel on client existing LAN/WAN. Each loop may have a capacity of minimum 125 detectors & devices in one loop, 240 volts AC power supply. (Make:- Honeywell Esser) = 1 no. | - | - | - | - |
| 1.02 | Supply, installation, testing and commissioning of Repeater Panel with 160 and above character display (Make:- Honeywell Esser) = 14 nos. | - | - | - | - |
| 1.03 | Intelligent Multisensor Detector with integrated fault isolator/ isolator Base. (Make:- Honeywell – Esser) = 1556 Nos. | - | - | - | - |
| 1.04 | intelligent analog addressable Heat Sensor/ detector (Including Rate of Rise Temp) with integrated fault isolator/ fault isolator base (Make: Honeywell) = 69 Nos. | - | - | - | - |
| 1.05 | addressable manual call point break glass unit with integrated fault isolator. (Makes: Honeywell – Esser) = 151 nos. | - | - | - | - |
| 1.06 | Analog Addressable Control modules with integrated fault isolator (Makes:- Honeywell- Esser)= 151 nos. | - | - | - | - |
| 1.07 | Addressable Loop Powered multi tone sounder of 80-90 db, with integrated short circuit isolator (Makes:- Honeywell- Esser)= 151 Nos. | - | - | - | - |
| 1.08 | Linear Beam Smoke Detector with addressable module having monitoring length 5 to 100m, IP42 protection (Makes:- Honeywell) = 28 Nos. | - | - | - | - |
| 1.09 | Response indicator (Makes:- Honeywell – Esser) = 602 Nos. | - | - | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 22.34 MB
BOQ_113744.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .