Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹6.9 L+₹2.2 L (45.4%)Rejected-Finance 2 44 A 4 KALU SARAI HAUZ KHAS DELHI SOUTH WEST DELHI DELHI 110016 | SOUTH DELHI | DELHI | 110016 | L2 | Rejected-Finance L2 |
Tender Value
₹4.7 L
EMD Value
₹9,500
Closing Date
17 Mar 2022, 6:00 pmClosed
ATUL BHARDWAJ
EEE/WZ
Repairing of tubewells installed in Various Municipal Parks alongwith allied accessories for proper functioning of tubewells in Ward No-12-S, 13-S, 18-S, 27-S and 29-s under West Zone .
2022_SDMC_110023_4
EE/Electrical/WZ/2021-22/43
Open Tender
Electrical Works
Works
240 days
WEST ZONE
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹9,500
25 Mar 2022
15 Mar 2022
21 Mar 2022
15 Mar 2022
17 Mar 2022
15 Mar 2022
Amount
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) single pole
(c) Triple pole & Neutral
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
P&F of following sizes of PVC insulated & PVC sheathed copper conductor 3 core submersible cable confirming to IS.694/1990 etc. as reqd. (a) 3 x2.5 sq.mm.
(b) 3 x4 sq.mm.
(c) 3X6 sq. mm
Supply, installation, testing and commissioning of cubical type control panel board for single phase & three phase submersible pumping set of following rating complete with contactor, relay ,condenser, MCB ,voltmeter, ammeter, VSS and indication lamp etc including connections etc as reqd. (a)1.5.HP (Single Phase)
(b)3.0.HP (Single Phase)
(c )5 HP (Three Phase)
(d) 7.5 H.P rating Submersible P/Set.
Supplying, lowering and fixing following size of G.I. Pipe (M- Class) i/c cutting threading on both sides etc ISI marked etc as reqd. (a) 32 mm dia
(b) 40 mm dia
(c) 50 mm dia
S& F following sizes of GI Elbow as reqd. (a) 32 mm dia
(b) 40 mm dia
(c) 50 mm dia
S&F following sizes of GI socket as reqd. (a) 32 mm dia
(b) 40 mm dia
(c) 50 mm dia.
Supplying and fixing following sizes of insulated steel flexible safety rope for holding submersible pump set i/c clips etc complete as required.
Lifting the existing submersible pump set 1 to 5 HP with all accessories from well and lowering the same from following depths complete as reqd. (a) from depths up to 40 meters deeps
(b) from depths more 40 meters upto 60 meters
Rewinding of single / three phase A.C.motors of vertical type multi stage submersible pump set (Dismantled material will be retained by contractor) of following ratings:- (a) Single phase 1.5 HP,
(b) Single phase 3 HP,
(c) Three phase 5 HP,
(d) Three phase 7.5 HP
Development of tube well with suitable capacity of air compressor i/c lowering of the necessary induction pipe or line i/c cost of fuel , hire charges of compressor etc as reqd . The development shall be considered complete when gravel stop sinking discharge ceased to improve and the sand contents are not more than 10 PPM after 20 minutes of starting the pump etc as reqd
Repairing of the Pumping unit of the Single phase (100 mm), vertical type, multistage, submersible pump set by replacement of following accessories/ parts etc compete as reqd. (a) Gun Metal Bush / Bearing.
(b) Pump Shaft.
(c) Impeller
Repairing of the Pumping unit of the Three phase (150 mm), vertical type, multistage, submersible pump set by replacement of following accessories/ parts etc complete as reqd. (a) Gun Metal Bush / Bearing.
(b) Pump Shaft.
(c) Impeller.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
150 mm dia. (Nominal Bore)
Providing ,lowering and fixing/ placing in vertical position MS Black casing pipe medium (B-class) pipe of following size conforming to IS 1239/3589 part-I(2004 ) at all depths ,both ends threaded as required
125mm(Nominal Bore)
150mm(Nominal Bore)
S & F MS clamp made up of iron flat of size 50x6 mm with 4 nut bolt for holding the GI pipe as reqd
Fabrication, supplying, installation and commissioning of canopy type floor mounted panel of size 650mmx850mmx300 mm deep board made out of 2 mm thick MS sheet with 600 mm long Legs of Angle Iron ( 50mmx50mmx5mm) having double doors, with 2 No. MV Danger Notice plates fixed on front doors i/c painting, connection, installation in cement concret complete with locking arrangement and suitable to accommodate ,Control Panel /starter, single phase preventor, MCD DB, energy meter etc. complete as reqd.
Providing and Fixing of canopy door 1 nos. of size 410mmX 560mm made out of 2mm thick MS Sheet along with locking joint duly welded at front along with 1 nos. of Brass butt hinges (light/ordinary type) of size 100x70x4 mm and welding the same on existing canopy body
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1:6 (1 cement : 6 coarse sand)
SWASTIK ELECTROTECH PRIVATE LIMITED
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .