| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹80.8 LAccepted-AOC 13 SOUTH PURBACHAL HOSPITAL RD CALCUTTA KOLKATA WEST BENGAL 700078 | KOLKATA | WEST BENGAL | 700078 | L1 | Accepted-AOC AS L-1 BIDDER | |
| 2 | L2₹82.2 L+₹1.4 L (1.79%)Rejected-Finance 9 VIDYASAGAR SARANI 2ND BYE LANE BIRATI NORTH 24 PARGANAS WEST BENGAL 700051 | 24 PARAGANAS NORTH | WEST BENGAL | 700051 | L2 | Rejected-Finance AS L-2 BIDDER | |
| 3 | L3₹91.0 L+₹10.3 L (12.7%)Rejected-Finance | L3 | Rejected-Finance AS L-3 BIDDER | |
| 4 | Not Admitted-PreQual/Technical 3 2 BHAGWAN GANGULY LANE HOWARH 711101 | HOWARH | HOWRAH | WEST BENGAL | 711101 | - | Not Admitted-PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-PreQual/Technical RAJARHAT KALIBARI ROAD NORTH 24 PARGANAS WEST BENGAL 700135 | 24 PARAGANAS NORTH | WEST BENGAL | 700135 | - | Not Admitted-PreQual/Technical Not Complied with technical specification |
Tender Value
₹75.6 L
Closing Date
9 Feb 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI RAHULDEB MUKHOPADHYAY, EE
ENGINEERING SERVICES DEPARTMENT, CSIR-CGCRI, KOLKATA
Day to day Electrical repairing, modification and renovation work at entire CSIR Staff Quarter complex, SIRSA including CSIR Guest House, Kolkata.
2021_CSIR_99856_2
GCW/E/14/21-22(W)
Open Tender
Electrical Works
Works
365 days
SIRSA Complex, Guest House
Please refer Tender documents.
11 documents required · 11 mandatory
₹1,000
CENTRAL GLASS AND CERAMIC RESEARCH INSTITUTE
Exempted
14 Mar 2022
31 Jan 2022
10 Feb 2022
31 Jan 2022
9 Feb 2022
31 Jan 2022
90 days
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Group A
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
2 X 16 sq. mm + 1 X 6 sq. mm earth wire
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
1 x 1.5 sq. mm
2 x 1.5 sq. mm
3 x 1.5 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.
150 mm X 150 mm X 60 mm deep
180 mm X 100 mm X 60 mm deep
200 mm X 125 mm X 60 mm deep
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
5/6 amps switch
2 way 5/6 amps switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Telephone socket outlet
T.V. antenna socket outlet
Bell Push
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Upto 450 mm sweep
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Dismantling of ceiling fan and painting the same with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins, reinstalling the same as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.
1 run of cable
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
125 Amp, 36 KA FP MCCB
200 Amp, 36 KA FP MCCB
250 Amp, 50 KA FP MCCB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way, Double door
12 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
6 way (4 + 18), Double door
8 way (4 + 24), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
4 way (4 + 12), Double door
8 way (4 + 24), Double door
12 way (4 + 36), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10KA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Single pole and neutral
Double pole
Triple pole
Triple pole and neutral
Supplying and fixing following rating, 415 volts, "C" curve, 10KA breaking capacity, FP miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40/63 Amp Four pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing FP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts "C" curve FP MCB complete with connections, testing and commissioning etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe for earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 70 sq. mm (38mm)
3½ X 95 sq. mm (45mm)
3½ X 120 sq. mm (45mm)
3½ X 150 sq. mm (50mm)
3½ X 185 sq. mm (57mm)
3½ X 240 sq. mm (62mm)
3½ X 300 sq. mm (70mm)
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required
50mm dia
80 mm dia
100 mm dia
150 mm dia
Welding charges
Supply of the following Items make as per attached make list:-
1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
4.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
6.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
10 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
16 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
20 mm iron staples/ saddles/ screws
25 mm iron staples/ saddles/ screws
32 mm iron staples/ saddles/ screws
40 mm iron staples/ saddles/ screws
20 mm dia. ISI marked, PVC conduit
25 mm dia. ISI marked, PVC conduit
32 mm dia. ISI marked, PVC conduit
20 mm PVC bends or Tee
25 mm PVC bends or Tee
32 mm PVC bends or Tee
20 mm space bar UPVC saddle
25 mm space bar UPVC saddle
32 mm space bar UPVC saddle
75 mm X 75 mm X 50 mm PVC box
Modular GI box for 2 module
Modular GI box for 3 module
Modular GI box for 4 module
Modular GI box for 6 module
Modular GI box for 8 module
Modular GI box for 12 module
75 mm X 75 mm X 60 mm deep metal box
100 mm X 100 mm X 60 mm deep metal box
150 mm X 75 mm X 60 mm deep metal box
150 mm X 150 mm X 60 mm deep metal box
180 mm X 100 mm X 60 mm deep metal box
200 mm X 300 mm X 60 mm deep metal box
3 mm thick phenolic laminated sheet
Ceiling rose, 3 pin, 5 amps ISI marked
S.P. 5/6 amps, one way modular switch, ISI marked
S.P. 5/6 amps, two way modular switch, ISI marked
S.P. 15/16 amps, one way modular switch, ISI marked
3 pin 5/6 amps modular socket outlet, ISI marked
6 pin 15/16 & 5/6 amps modular socket outlet, ISI marked
Modular Bell push, ISI marked
Stepped type modular Fan Regulator ( 2 module)
Telephone socket outlet modular type
T.V. socket outlet modular type
Modular Blanking Plate
6 Pin 25 amp modular type socket ISI marked
Modular base & cover plate for 1 module
Modular base & cover plate for 2 module
Modular base & cover plate for 3 module
Modular base & cover plate for 4 module
Modular base & cover plate for 6 module
Modular base & cover plate for 8 module
Modular base & cover plate for 12 module
S.P. 5/6 amps, one way switch, piano type ISI marked
S.P. 5/6 amps, two way switch, piano type ISI marked
S.P. 15/16 amps, one way switch, piano type ISI marked
3 pin 5/6 amps socket outlet, piano type ISI marked
6 pin 15/16 & 5/6 amps socket outlet, piano type ISI marked
Bell push, piano type
3 pin plug top,6A, unbreakable/polycarbonate, isi marked
3 pin plug top,16A, unbreakable/polycarbonate, isi marked
3 pin plug top,16A with indicator, unbreakable/polycarbonate, isi marked
Door bell, ding dong, single phase
32 Amp DP switch with Indicator
32A Key tag mechanical mono block( 2M)
UTP 4 Pair CAT 6 LAN Cable
PVC Batten / angle holder
6A to 32A ratings, SP MCB, 'C' Curve 10 KA breaking capacity, Conforms to IS/IEC 60898 - 10kA & IEC 60947
6A to 32A ratings, DP MCB, 'C' Curve 10 KA breaking capacity, Conforms to IS/IEC 60898 - 10kA & IEC 60947-2
6A to 32A ratings, TP MCB, 'C' Curve 10 KA breaking capacity, Conforms to IS/IEC 60898 - 10kA & IEC 60947-2
16/20/25/32 amps, 10KA, C series FP MCB, Conforms to IS/IEC 60898 - 10kA & IEC 60947 - 2
40A/ 63A ratings, DP MCB, 'C' Curve 10 KA breaking capacity, Conforms to IS/IEC 60898 - 10kA & IEC 60947-2
40/63 amps, 10KA, C series TP MCB, Conforms to IS/IEC 60898 - 10kA & IEC 60947 - 2
40/63 amps, 10KA, C series FP MCB, Conforms to IS/IEC 60898 - 10kA & IEC 60947 - 2
63A ratings, FP RCCB, sensitivity- 300mA, Conforms to IS 12640 (Part 1) / IEC 61008-1
4 pole MCCB, 125A, 36kA, Conforms to IS/IEC 60947-2 & IEC 60947-2
4 pole MCCB,250A, 36kA, Conforms to IS/IEC 60947-2 & IEC 60947-2
4 pole MCCB,400A, 50kA, Conforms to IS/IEC 60947-2 & IEC 60947-2
Gl saddles 19 mm x 0.55 mm for conduit
Gl saddles 25 mm x 0.90 mm for conduit above 25 mm
MCCB encloser box (sheet steel, 2mm /14 SWG) on the wall in surface / conceal fashion including mounting arrangement of MCCB complete in all respects for four pole 100 A/ 125A MCCB
MCCB encloser box (sheet steel, 2mm /14 SWG) on the wall in surface / conceal fashion including mounting arrangement of MCCB complete in all respects for four pole 250 A MCCB
FP, 2W Manual Changeover Switch in sheet steel enclosure, 100A
FP, 2W Manual Changeover Switch in sheet steel enclosure, 200A
PVC Insulation Tape of 3 mtr. roll(R/Y/Blue/G/ Black)
Hammering Drill Bit 6.5 mm x 100 mm
Hammering Drill Bit 8 mm x 100 mm
Hammering Drill Bit 10 mm x 100 mm
HSS Drill Bit 4.5 mm
HSS Drill Bit 6.5 mm
HSS Drill Bit 8.5 mm
HSS Drill Bit 10.5 mm
Wooden screw , 35/8 mm
Wooden screw , 25/7 mm
Round Headed Self thread screw 12/4
Round Headed Self thread screw 19/6
Round Headed Self thread screw 25/7
Round Headed Self thread screw 35/8
Brass screw, 4.5mm x 35mm
Cap washer for brass screw
Silica Gel for Transformer Breather
Silica Gel Breather, Model- DTO-2
CTC spray (170gm/ 150ml)
Rubber reel, nut & bolts with washers and safety pin ( for mounting of ceiling fan)
G.l. nuts and through bolts with washer
Welding rod (8no / 10 no / 12 no)
Iron Cutter Blade- 4" dia
3P4 W, Multistep Switch with Off, 16A
3P 4 W, Multistep Switch with Off, 32A
6 way, SPN, double door, MCB DB
8 way, SPN, double door, MCB DB
12 way, SPN, double door, MCB DB
Sheet steel DP MCB enclosure
Sheet steel TP/FP MCB enclosure
Brass compression gland for (38mm) 3.5 x 70 sqmm 1.1 KV grade cable
Brass compression gland for (45mm) 3.5 x 95 /120 sqmm 1.1 KV grade cable
Brass compression gland for (50mm) 3.5 x 150 sqmm 1.1 KV grade cable
Brass compression gland for (57mm) 3.5 x 185 sqmm 1.1 KV grade cable
Brass compression gland for (62mm) 3.5 x 240 sqmm 1.1 KV grade cable
Brass compression gland for (70mm) 3.5 x 300 sqmm 1.1 KV grade cable
Brass compression gland for (25mm) 4 x 10 sqmm 1.1 KV grade cable
Brass compression gland for (28mm) 4 x 16 sqmm / 25 sqmm 1.1 KV grade cable
Brass compression gland for (32mm) 4 x 35 sqmm 1.1 KV grade cable
Brass compression gland for (35mm) 4 x 50 sqmm 1.1 KV grade cable
Copper lugs for 1.5 sq. mm cable (Ring/Pin)
Copper lugs for 2.5 sq. mm cable (Ring/Pin)
Copper lugs for 4.0 sq. mm cable (Ring/Pin)
Copper lugs for 6.0 sq. mm cable (Ring/Pin)
Copper lugs for 10 sq. mm cable (Ring/Pin)
Copper lugs for 16 sq. mm cable (Ring/Pin)
Copper lugs for 25 sq. mm cable (Ring)
Copper lugs for 35 sq. mm cable (Ring)
Copper lugs for 70 sq. mm cable (Ring)
Aluminium lugs for 16 sq. mm cable
Aluminium lugs for 25 sq. mm cable
Aluminium lugs for 35 sq. mm cable
Aluminium lugs for 50 sq. mm cable
Aluminium lugs for 70 sq. mm cable
Aluminium lugs for 95 sq. mm cable
Aluminium lugs for 120 sq. mm cable
Aluminium lugs for 150 sq. mm cable
Aluminium lugs for 185 sq. mm cable
Aluminium lugs for 240 sq. mm cable
Aluminium lugs for 300 sq. mm cable
Al. Alloy/ cadmium plated iron screws, 20 mm
Iron screws, 35 mm X 6 mm
Iron screws, 40 mm X 6 mm
Iron screws, 45 mm X 6 mm
Steel fastner 6mm x 75 mm
Steel fastner 8mm x 75 mm
PVC Clip for fixing cable
Cotton waste, cleaning cloth etc.
Cleaning materials like soap/ detergent
Tin solder wire etc.
Charcoal
Paint
Piano type 100 watt Ceilling fan deluxe rotary step regulator white colour ( socket type)
8" x 6" x 1.75" Top less wooden board
8" x 10" x 1.75" Top less wooden board
8" x 12" x 1.75" Top less wooden board
10" x 12" x 1.75" Top less wooden board
24V 20AH Pulse Battery (Cumin's Cat no - AX1013235)
20mmx12mm double lock PVC casing-capping
25mmx16mm double lock PVC casing-capping
32mmx16mm double lock PVC casing-capping
Pvc trunking & trunklinks (casing-N-caping), 100x50.
Corrugated FRPP flexible conduit - 20 mm
Corrugated FRPP flexible conduit - 25 mm
Corrugated FRPP flexible conduit - 32 mm
Corrugated flexible conduit Gland - 20 mm
Corrugated flexible conduit Gland - 25 mm
Corrugated flexible conduit Gland - 32 mm
32/0.20 mm (1.0 sq.mm) twin circular, FRLS PVC sheathed,workshop flexible copper cable
Straight through cable jointing kit with heat shrinkable kit with ferrules for 3&1/2 X 120 sq. mm 1.1 kV grade cable
Straight through cable jointing kit with heat shrinkable kit with ferrules for 3&1/2 X 185 sq. mm 1.1 kV grade cable
50 mm dia. G.l. pipe (medium class)
80 mm dia. G.l. pipe (medium class)
100 mm dia. G.l. pipe (medium class)
25 mm X 3mm bolts & nuts
32 mm X 8mm bolts & nuts
38 mm X 10mm bolts & nuts
25 mm X 5 mm G.l. strip (1.0 kg/meter)
6 SWG G.l. wire
Flat iron clamps (50 mm X 6 mm) for G. I. pipe
Heavy Duty Square Capacitor for Non Linear Load Champ 440V 50 Hz-3 KVAr 3PH
Heavy Duty Square Capacitor for Non Linear Load Champ 440V 50 Hz-5 KVAr 3PH
Heavy Duty Square Capacitor for Non Linear Load Champ 440V 50 Hz-12.5KVAr 3PH
Oil Type metal body, Fan Capacitor 2.25 MFD/440V
Oil Type metal body Fan Capacitor 2.5 MFD/440V
Oil Type metal body Fan Capacitor 3.15 MFD/440V
Flat Three Core 1100 V grade XLPE Insulated industrial flexible cable for submersible pump motor; nominal area of copper conductor - 6 sq.mm.
Flat Three Core 1100 V grade XLPE Insulated industrial flexible cable for submersible pump motor; nominal area of copper conductor - 10 sq.mm.
Ring Type LT Current Transformer -- 50/5 A, Burden 5 VA, Class -I
Ring Type LT Current Transformer -- 100/5 A, Burden 15 VA, Class -I
Ring Type LT Current Transformer -- 250/5 A, Burden 15 VA,Class -I
GI socket with ISI mark 80 mm dia.
GI socket with ISI mark 100 mm dia.
4" x 4" PVC Boards
4" x 7" PVC Boards
6" x 6" PVC Boards
6" x 8" PVC Boards
8" x 10" PVC Boards
10" x 12" PVC Boards
Bush-bearing (with felt) of 12” exhaust fan or cabin fan.
Bush-bearing (with felt) of 15” exhaust fan or cabin fan.
250 mm X 200 mm H.T. danger notice plate
200 mm X 150 mm M.V. danger notice plate
9 V Battery for Clamp-on meter/ Multimeter
4/4.5 V 1 Ah Battery for Lift Hooter
12 V 18 Ah Battery for ARD of Lift
SMF 6 V 5 Ah Battery
AA Alcaline Battery
AAA Alcaline Batter
Ball-bearing Size 6201ZZ
Ball-bearing Size 6202ZZ
Ball-bearing Size 6203ZZ
Ball-bearing Size 6204ZZ
Ball- bearing Size S7
Ball- bearing Size 608
Louver Shutter for 12" Exhaust fan
Safety Helmet
1200 mm Celing fan, Opal white
1400 mm Celing fan, Opal white
400 mm wall mounted oscillating type cabin fan, hi speed
300 mm Heavy duty exhaust Fan, 1ph., 1400 rpm
450 mm Heavy duty exhaust Fan, 1ph., 1400 rpm
400mm Pedestal Fan, Opal White
AC Single Ph. Static energy meter of accuracy class 1.0, 240V, 50 Hz with Backlit LCD Displays of rating 10-60 A (measures & displays kWh only)
AC three Ph. Static energy meter of accuracy class 1.0, 3 x 240V, 50 Hz with Backlit LCD Displays of rating 10-60 A (measures & displays kWh,V,I,kW, MD) with 3 nos. push buttons
Fully Automatic Star-Delta Starters in sheet-Steel Encloser with Single Phase Protection for upto 25/30 HP Pump 415V, 3-Ph, Relay range 14-23 A
Single Phase, 25 Amp 2M motor starter for Air-Conditioner, Colour white
Automatic Single phase motor starter (11 to 21 Amps) with VOLTCHECK, AMPCHECK & TIMECH CHECK & 3 digit display, Model OLP-3 +, Electron make
Transformer oil IEC 60296:2003
3 pole power contactor L&T MNX type AC3 rating 18A
3 pole power contactor L&T MNX type AC3 rating 25A
3 pole power contactor L&T MO type AC3 rating 18A
3 pole power contactor L&T MO type AC3 rating 25A
Power Factor Controller, 8 step, 415 V
1 way, 20 mm PVC Circular Box
2 way, 20 mm PVC Circular Box Angle/Through
3 way, 20 mm PVC Circular Box
4 way, 20 mm PVC Circular Box
1 way, 25 mm PVC Circular Box
2 way, 25 mm PVC Circular Box
3 way, 25 mm PVC Circular Box
4 way, 25 mm PVC Circular Box
Supply, testing and commissioning of 440V electrical contactor conforming IS / IEC 60947-4-1 & IEC 60947-4-1. (capacitor duty, Type MO C)
Supply of 1.1 KV grade following XLPE insulated Armoured cable confirming the IS 7098 (Part 1) 1988 specification:-
3.5 Core 120 sq.mm. Al. Cable.
3.5 Core 185 sq.mm. Al. Cable.
3.5 Core 300 sq.mm. Al. Cable.
4 Core 1.5 sq.mm. copper cable.
4 Core 2.5 sq.mm. copper cable.
4 Core 4 sq. mm. copper cable.
4 Core 6 sq. mm. copper cable.
4 Core10 sq.mm. copper cable
4 Core16 sq.mm. copper cable
4 Core 25 sq.mm. copper cable
4 Core 35 sq.mm. copper cable
3.5 Core 50 sq.mm. copper cable
3.5 Core 70 sq.mm. copper cable
Supply of 1.1 KV grade following PVC insulated PVC sheathed cable of confirming the IS 694 :2010 specification:-
3 Core 1.5 sq.mm. copper cable.
3 Core 2.5 sq.mm. copper cable.
4 Core 6 sq. mm. copper cable.
4 Core 10 sq. mm. copper cable.
4 Core 16 sq. mm. copper cable.
Supply of following Luminaries having min. CRI 70 strictly approved by engineer in charge--
6W Ultra slim decorative aluminium casted, recess mounted round fixture in white finish with opal diffuser and seperate electronic driver, suitable for low depth ceiling
10W batten LED complete set with minimum efficacy of 100 Lumens per watt, THD less than 10%
20W batten LED complete set with minimum efficacy of 100 Lumens per watt, THD less than 10%
Slim, compact, al. die cast edge lit panel, having recess mounted square fixture with opal diffuser and separate electronic driver -- 12W, 6500K
Slim, compact, al. die cast edge lit panel, having recess mounted square fixture with opal diffuser and separate electronic driver -- 15W, 6500K
Trim square, back lit, zero bezel LED panels with inbuilt driver in PC body, premium asthetics with wider light coverage-- 12 W, 6500K
Trim square, back lit, zero bezel LED panels with inbuilt driver in PC body, premium asthetics with wider light coverage-- 18 W, 6500K
Bulkhead designed with premium quality diffuser for glarefree light and easy to install snapfit installer-- 13.5W round, 6000K
15W B22 cap LED bulb
9W B22 cap LED bulb
LED street light made up of pressure die cast aluminium housing and lens embedded PC cover and top opening separate driver compartment with IP 66 protection complete with 25W LED
LED street light made up of pressure die cast aluminium housing and lens embedded PC cover and top opening separate driver compartment with IP 66 protection complete with 45W LED
LED street light made up of pressure die cast aluminium housing and lens embedded PC cover and top opening separate driver compartment with IP 66 protection complete with 60W LED
LED street light made up of pressure die cast aluminium housing and lens embedded PC cover and top opening separate driver compartment with IP 66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device with 90W LED
Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium flood light with high power LED-- 60Watt
Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light with high power LED-- 100Watt
Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light with high power LED-- 150Watt
Supply of following Busbar and busbar chamber The busbar chamber should be hinged stove enamel painted, sheet steel 16 s.w.g.
Busbar - 4x400x20x3 in mm. Copper. Enclosure-600x400x150 in mm.
Busbar - 4x200x20x5 in mm. Copper. Enclosure-300x300x150 in mm.
Testing of following parameters of Transformer-oil/ LT OCB Oil/ HT OCB Oil, by a reputed Government authorized agency, as per I.S. Specification ---- 1) Moisture Content, 2) Acidity, 3) Die-electric Dissipation factor, 4) Die-electric Strength, as per instruction by the Engineer-in-charge & submission
Complete overhauling of the existing 200 Amps L.T. O.C.B., (other than breakdown maintenance), which includes all necessary checking except setting/ calibration, ( incuding checking the cassel lock), cleaning (using C.R.C. etc.), necessary servicing, re-assembling, refilling , filtration & dehydration as per instruction by the Engineer-in-charge
Complete overhauling of the existing 800 Amps L.T. O.C.B., (other than breakdown maintenance), which includes all necessary checking except setting/ calibration, ( incuding checking the cassel lock), cleaning (using C.R.C. etc.), necessary servicing , re-assembling, refilling , filtration & dehydration as per instruction by the Engineer-in-charge
Complete overhauling of the existing 3ph., 6000/415 V 250 KVA Transformer (by core lifting)(other than breakdown maintenance) which includes – all necessary checking, ( with necessary draining & making temporary arrangement of storing that oil), testing for any oil leakage , rectification as per instruction by the Engineer-in-charge
Complete overhauling of the existing Potential Transformer connected with 400Amps H.T.-O.C.B., (other than breakdown maintenance) which includes – all necessary checking , (with necessary draining & making arrangement of storing that oil ), cleaning (using C.R.C. etc.), necessary servicing and rectification as per instruction by the Engineer-in-charge.
Complete overhauling of the existing 400 Amps H.T. O.C.B. (other than breakdown maintenance), which includes – all necessary checking, except setting/ calibration, ( incuding checking the cassel lock), cleaning (using C.R.C. etc.), necessary servicing and rectification as per instruction by the Engineer-in-charge.
Full Comprehensive breakdown maintenance of 01 no. Grundfoss make stainless steel 12.5 Hp Submmersible pump-motor set fitted inside ground reservoir including supply of all spare parts along with lifting , lowering, commissioning etc, if necessary.
Full Comprehensive breakdown maintenance of 01 no. KBL make 25 Hp Submmersible pump-motor set fitted inside ground reservoir including supply of all spare parts along with lifting , lowering, commissioning etc., if necessary
Supply, Installation, testing & Commissioning of KSB make Submersible Pump set having capacity of 25 hp with a head ranging from 74 to 38 mtr. @ discharge ranging 40 to 110 cu.mtr./hr.
Supply of spare parts for window type 1.5 Tr. Air-conditioner confirming indian standard ( if applicable) strictly approved by Engineer-in-charge.
New complete body (G.I. sheet), duly painted, with Condensor coil guard & cooling coil guard , thermal insulation, fan-base, box for electrical parts & vents
Leg Rubber of motor, standard quality
Base plate with bitumin compound
Outer cover with net, painted, standard quality
Front grill without swing motor set, (suitable for existing Bluestar/ Samsung / Weathermaker/voltas make machine)
100% Cu. Cooling coil ( voltas/ samsung make)
Fan motor without blade (American Universal / GE or equivalent make )
Plastic blade for internal fan
Fan motor capacitor- OIL TYPE 4 mfd.
220V, 4 W, 4.1/5 rpm swing motor
Fan motor complete repairing i/c. bush (except rewinding)
Runner of fan motor(plastic)
Runner of fan motor (metal)
Strainer, standard quality
Strainer with capillary tube
Suction line thermal insulation material, PU type (in tube form) of 1/2"
Suction line thermal insulation material, PU type (in tube form) of 1/4"
Suction line thermal insulation material, PU type (in tube form) of 3/8"
Suction line thermal insulation material, PU type (in tube form) of 5/8"
Body thermal insulation material (using denrite adhesive as required )
Cooling coil filter-synthetic
Cooling coil filter- normal
Reciprocating compressor (with 6 months warranty)
PTC Relay
Starting Capacitor of compressor motor---60-100 mfd.
Starting Capacitor of compressor motor---80-100 mfd
Running Capacitor of compressor motor --- 50 mfd
Running Capacitor of compressor motor --- 36 mfd.
Clip with sleeve ( 12 pcs.) with wire-set to fix the compressor
Plastic/ Rubber flexible drain pipe(1/2” dia)
1/4 ” dia Copper pipe, standard quality
3/8 ” dia Copper pipe, standard quality
Plastic water tray (for drainage purpose)
Remote circuit all complete (with 6 month's warrantee),
Refrigerant- R410A
Refrigerant- R- 32
Refrigerant- R22
Repairing of Remote circuit for Volats/ Samsung make existing window type A.C. machine
Complete washing of the refrigerant circuit using Nitrogen with proper vacuuming, moisture drying & thorough leak testing of existing 1.5 ton window air-conditioner & proper Gas charging i/c. cost of refrigerant.
Supply of spare parts for 15 ltrs., 2 kW storage geyser ( Bajaj/ Voltas make, existing) confirming indian standard ( if applicable) strictly approved by Engineer-in-charge.
Heating element
Gasket, standard quality
Thermostat, standard quality
Indicator lamp
Connector pipe ( PVC/ Metallic)
Repairing of water tank ( L.S.)
Supply of spare parts for existing 285 ltr. Refrigerator (Whirlpool make) confirming indian standard (if applicable) strictly approved by Engineer-in-charge.
Fan motor
Thermostat, standard quality
Bottle guard ( Plastic/ fibre)
Timer connected with heating coil
Heater Coil
Bi-metal
Overload Relay
Condensing Coil
Cooling Coil
Reciprocating compressor (with min. 6 months warranty)
Complete washing of the refrigerant circuit using Nitrogen with proper vacuuming, moisture drying & thorough leak testing of existing 285 ltr. refrigerator & proper Gas charging i/c. cost of refrigerant.
Supply of spare parts for existing 165 ltr. Refrigerator (Godrej make) confirming indian standard (if applicable) strictly approved by Engineer-in-charge.
Fan motor
Thermostat, standard quality
Bottle guard ( Plastic/ fibre)
Condensing Coil
Cooling Coil
Reciprocating compressor (with min. 6 months warranty)
Complete washing of the refrigerant circuit using Nitrogen with proper vacuuming, moisture drying & thorough leak testing of existing 165 ltr. refrigerator & proper Gas charging i/c. cost of refrigerant.
Supply of spare parts for existing 120 ltr. Refrigerator (Godrej make) confirming indian standard (if applicable) strictly approved by Engineer-in-charge.
Fan motor
Thermostat, standard quality
Bottle guard ( Plastic/ fibre)
Condensing Coil
Cooling Coil
Reciprocating compressor (with min. 6 months warranty)
Complete washing of the refrigerant circuit using Nitrogen with proper vacuuming, moisture drying & thorough leak testing of existing 120 ltr. refrigerator & proper Gas charging i/c. cost of refrigerant.
For repairing and maintaining of electrical equipment like OCB, ACB, MCCB, Metering panel, light, Fan etc., Record keeping of meters, operating of pumps, attending job cards as per requisition etc. Electrician with Electriacal License from Licensing Authority is required. Contract Labour (Regulation & Abolition) Act, 1970 to be followed by the contractor during the execution of work. (As per Annexure-A)
Semi-Skilled electrician 5 head 26 days in a month for 12 months
Skilled electrician 5 head 26 days in a month for 12 months
SWADESH AGRO TECH
BHARAT ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .