| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC Lowest Bid Found in Order |
| 2 | L2₹1.1 Cr+₹6.8 L (6.35%)Rejected-Finance VILL MOHANPUR PO SEWLI TELINI PARA PS TITAGARH DIST 24 PGS NORTH KOLKATA 700121 | 24 PARAGANAS NORTH | WEST BENGAL | 700121 | ₹1.1 Cr+₹6.8 L (6.35%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹1.5 Cr+₹41.0 L (38.0%)Rejected-Finance | ₹1.5 Cr+₹41.0 L (38.0%) | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹2.0 Cr+₹92.3 L (85.7%)Rejected-Finance NOT SPECIFIED | ₹2.0 Cr+₹92.3 L (85.7%) | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
₹92 L
EMD Value
₹1.6 L
Closing Date
16 Jul 2024, 6:00 pmClosed
CE (AF) PRAYAGRAJ
HQ CE (AF) PRAYAGRAJ Bamrauli 211012
Completion of incomplete work against CA No CE(AF)/ALD/DBG/14 of 2015-2016 work services for alternate ATC Building at AF Stn Darbhanga
2024_MES_652951_1
958819/e8
Open Tender
Civil Works
Lump-sum
180 days
Darbhanga
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (AF) Bihta
₹1.6 L
Yes
2 Sept 2024
9 May 2024
23 Jul 2024
9 May 2024
16 Jul 2024
2 Jul 2024
Amount
SCHEDULE A PART I (BUILDING WORKS)
Lump sum price worked out by the contractor for completion of incomplete work in respect of Construction of permenent Alternate ATC Bldg (Semi underground) alongwith RCC wall, VIFT (earth traverses), PCC plinth protechtion, saucer drain, Toe wall etc, complete all as specified and as shown on drawings.
Lump sum price worked out by the contractor for completion of incomplete work in respect of Construction of sub Station building for power house, complete all as specified and as shown on drawings. Note for item Nos 1.01 and 1.02: (i) Approximate quantities of balance works are attached as Appendix 'A' to the Schedule 'A'. (ii) Please note that the percentage of balance works given in Appendix 'A' are not firm and the bidder shall assess his own percentage with reference to contract drawings and other conditions, after site visit before quoting the tender. Cost of any other items leftover with reference to contract drawings & conditions, and any other works required preparatory to complete the balance works shall be deemed included in the lump sum quoted for this schedule. Nothing extra shall be admissible on the ground of requirement of any other items or variation of percentage if any found at later stage.
Sch A Part II (INTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for Internal water supply as listed in Sch ‘A’ Part II.
Sch A Part III (INTERNAL ELECTRIFICATION)
Lump sum price worked out by the contractor for Internal Electrification as listed in Sch ‘A’ Part III .
Sch A Part IV (EXTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for External Water Supply as listed in Sch ‘A’ Part IV .
Sch A Part V (EXTERNAL ELECTRIFICATION)
Lump sum price worked out by the contractor for External electrification as listed in Sch ‘A’ Part V.
Sch A Part VI (ROAD, PATH AND CULVERT)
Lump sum price worked out by the contractor for Road, Path and Culvert as listed in Sch ‘A’ Part VI.
Sch A Part VII (SEWAGE DISPOSAL)
Lump sum price worked out by the contractor for Sewage Disposal as listed in Sch ‘A’ Part VII
Sch A Part VIII (AREA DRAINAGE)
Lump sum price worked out by the contractor for Area drainage as listed in Sch ‘A’ Part VIII
Sch A Part IX (PVC CONDUIT)
Lump sum price worked out by the contractor for PVC Conduit supply as listed in Sch ‘A’ Part IX
Sch A Part X (GATE AND FENCING)
Lump sum price worked out by the contractor for Gate and Fencing as listed in Sch ‘A’ Part X
Sch A Part XI (COOLING APPLIANCES)
Lump sum price worked out by the contractor for Cooling appliances as listed in Sch ‘A’ Part XI
Sch A Part XII (SITE CLEARANCE, EXCAVATION AND EARTH WORK)
Lump sum price worked out by the contractor for Site clearence, Excavation and earth work as listed in Sch ‘A’ Part XII
SCHEDULE A PART XIII (MISCELLANEOUS B/R & E/M ITEMS) (INTERNAL ELECTRIFICATION) : - Supplying and erecting decorative wall mounted fans electric driven suitable for AC 250 Volts , 50Hz single phase electric supply, with pivot arrangement for tilting and oscillation, three speed with speed regulator, 400mm sweep, power consumption approximately 55 watts, 1300-1800 RPM, colourless blade including connecting up with 3 core PVC insulated multistranded copper conductor cable complete all as specified and as directed. Make :- Bajaj Midea BW 04 wall fan or equivalent in Usha, Crompton Greaves, Khaitan
Supplying and fixing heavy duty, BEE 5 star labelled Exhaust fan of 375 mm sweep, 900 rpm speed, 230 Volts, approximately 2460 Cubic meter per hour air delivery with all accessories and necessary materials, suitable to work on 230 V , AC Supply 50 Hz, erected in position, :ISI marked Exhaust fan , capacitor run with mounting ring, four numbers of fixing hole without regulator and with louvers. Fan motor with moisture proof treatment and E class insulation, ISI marked, conforming to IS: 2312/67 with amendments 1 to 8. The fan mounting rings shall be proper pre-treatment followed with at least two coats of primer; final finish shall be with two coats of grey colour paint duly baked. The connecting leads shall be brought out for making connections. Paint: Superior quality enamel paint of specified colour. Make: Usha, Orient, Khaitan, Bajaj & Crompton Greaves
Supplying and Fixing MCB of Single poles, 10 KA, 6-32 Amps and of "B" series with required wiring connections & lugs etc. and erecting in provided enclosure / distribution board. MCB’s shall be of current limiting type, ISI marked confirms to IS 8828 – 1996. The power loss per pole shall be low and shall be in accordance with IS 8828 –1996. All cable entries shall be either from bottom or top. MCB’s shall be of B- curve characteristic & shall have quick make & break non-welding self wiping silver alloy contacts for 10 kA short circuit both on the manual & automatic operation. All the active, live parts of MCB’s should be out of human reach, ensuring safety & confirms to IP: 55 degree of protection. The MCB’s must house transparent label holder to ensure circuit identification. The MCB’s must have fully insulated safety shutters. The MCB’s shall have lockable switching lever. The Minimum electrical endurance shall be 20,000 operations. The housing of the MCB shall be mounted self-extinguishing DMC (Dough Moulding Compound). The short circuit Current shall be brought to zero within 4 to 5 milliseconds from the time they are established. All MCB’s shall have a minimum short circuit Capacity of 10kA RMS.
Supplying and Fixing MCB of Four Pole, 10 KA, 32 Amps of C Series, with required wiring connections & lugs etc. and erecting in provided enclosure / distribution board. MCB’s shall be of current limiting type, ISI marked confirms to IS 8828 – 1996. The power loss per pole shall be low and shall be in accordance with IS 8828 –1996. All cable entries shall be either from bottom or top. MCB’s shall be of C- curve characteristic & shall have quick make & break non-welding self wiping silver alloy contacts for 10 kA short circuit both on the manual & automatic operation. All the active, live parts of MCB’s should be out of human reach, ensuring safety & confirms to IP: 55 degree of protection. The MCB’s must house transparent label holder to ensure circuit identification. The MCB’s must have fully insulated safety shutters. The MCB’s shall have lockable switching lever. The Minimum electrical endurance shall be 20,000 operations. The housing of the MCB shall be mounted self-extinguishing DMC (DoughMoulding Compound). The short circuit Current shall be brought to zero within 4 to 5 milliseconds from the time they are established. All MCB’s shall have a minimum short circuit Capacity of 10kA RMS.
Supplying and Fixing MCB of Four Pole, 25 KA, 100 Amps of B or C Series, with required wiring connections & lugs etc. and erecting in provided enclosure / distribution board. MCB’s shall be of current limiting type, ISI marked confirms to IS 8828 – 1996. The power loss per pole shall be low and shall be in accordance with IS 8828 –1996. All cable entries shall be either from bottom or top. MCB’s shall be of C- curve characteristic & shall have quick make & break non-welding self wiping silver alloy contacts for 10 kA short circuit both on the manual & automatic operation. All the active, live parts of MCB’s should be out of human reach, ensuring safety & confirms to IP: 55 degree of protection. The MCB’s must house transparent label holder to ensure circuit identification. The MCB’s must have fully insulated safety shutters. The MCB’s shall have lockable switching lever. The Minimum electrical endurance shall be 20,000 operations. The housing of the MCB shall be mounted self-extinguishing DMC (DoughMoulding Compound). The short circuit Current shall be brought to zero within 4 to 5 milliseconds from the time they are established. All MCB’s shall have a minimum short circuit Capacity of 10kA RMS.
Supplying and Fixing MCB of double Pole, 10 KA, 6 to 32 Amps of C Series, with required wiring connections & lugs etc. and erecting in provided enclosure / distribution board. MCB’s shall be of current limiting type, ISI marked confirms to IS 8828 – 1996. The power loss per pole shall be low and shall be in accordance with IS 8828 –1996. All cable entries shall be either from bottom or top. MCB’s shall be of C- curve characteristic & shall have quick make & break non-welding self wiping silver alloy contacts for 10 kA short circuit both on the manual & automatic operation. All the active, live parts of MCB’s should be out of human reach, ensuring safety & confirms to IP: 55 degree of protection. The MCB’s must house transparent label holder to ensure circuit identification. The MCB’s must have fully insulated safety shutters. The MCB’s shall have lockable switching lever. The Minimum electrical endurance shall be 20,000 operations. The housing of the MCB shall be mounted self-extinguishing DMC (DoughMoulding Compound). The short circuit Current shall be brought to zero within 4 to 5 milliseconds from the time they are established. All MCB’s shall have a minimum short circuit Capacity of 10kA RMS.
M&L for sub main wiring using approved colour coding (Phase-Red, Neutral-Black, Earth -Green) with two single core FRLS PVC insulated, unsheathed stranded copper conductor cable of sizes Two runs of 6.0 Sq mm as current carrying conductors, and one run of 6.0 Sq mm as earth continuity conductor , voltage rating up to and including 1100 volts, ISI Marked. drawn in and including concealed PVC conduit ISI Marked of dia not less than 20 mm with stranded accessories, along with one run of FRLS PVC (green colour) insulated , unsheathed , stranded copper conductor of size as under Sqmm as earth continuity conductor all as specified and directed (Note Two run of single core FRLS PVC cable with one run of earth conductor and conduit shall be measured as one unit).
Supply and fix LED lights fittings 1 x 20 watt 220V, AC decorative box type aluminimum die cast housing with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. .
Supply and fix LED lights fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC die cast aluminimum housing with driver, holder, LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. .
Supply and fix LED bulb 1 x 9 w with holder complete all as specified and directed.
M&L for sub main wiring for three phase and Neutral with earth , using approved colour coding (Phase-Red, Yellow and Blue, Neutral-Black, Earth -Green) with three core FRLS PVC insulated, unsheathed stranded copper conductor cable of sizes Four runs of 6.0 Sqmm as current carrying conductor and Two runs of 6.0 Sqmm as earth continuity conductor. voltage rating up to and including 1100 volts, ISI Marked. drawn in and including concealed PVC conduit of dia not less than 25 mm with standard accessories, along with two run of FR PVC (green colour) insulated , unsheathed , stranded copper conductor of size as under as earth continuity conductor all as specified and directed (Note Four run of single core FRLS PVC cable with two run of earth conductor and conduit shall be measured as one unit).
Supply and fix street light fitting ,T5 fluorescent tube light type, muncell grey stove enameled finished sheet steel housing with stove enameled CRCA sheet steel reflector cover, ribbed acrylic bowl cover & accessories. suitable for T5 fluorescent tube light fitting , (2 x 28 Watt) with two tube T5 1x28 watt complete with electronic ballast and prewired fixing direct to wall with and including GI pipe 40 mm dia bent to shape up to 1.5 Meter in length along with fixing clamps and other accessories and connected with 0.5 Sq mm twin core PVC flexible cable etc all as specified Make Bajaj type BTSLF 228 T5 or Equivalent in Phillips/Wipro/Crompton Greaves Make
Supply, fabricating, fixing and testing enclosures for motor starter outdoor type wall or floor mounted type made out of 2 mm thick MS sheet front opening including DOL starter 3 Phase, 415 Volts AC suitable for up to 2 HP motor-1 No, MCB TP 20 Amps 10 KA, C Curve-1 No., LED Indicator lamp RYB-1 Set Single Phase preventer- 1 No, all accessories prewired complete all as specified and directed.
Supply and fix monoblock pump set, electric driven, single phase 220-250 Volts , AC 50 HZ supply, suitable for 3-40 meter head, 3300-250lph discharge, 0.5 HP, (0.37 KW) with brass impellers, carbon steel shaft, delivery and mounting casing of cast iron complete including 3 meters of not less than 15mm dia suction pipe and 10 meters of not less than 15mm dia delivery pipe and electric connection etc make:- Kirloskar, Tullu, Beacon, Sameer, Havells
(EXTERNAL WATER SUPPLY) Material and Labour for construction of brick masonary pit chamber of internal size 450 x 450 x 450 mm with locable MS cover fabricated with angle iron frame of size 20 mm x 20 mm x 6 mm thick, with Mild Steel plate cover 6mm thick, painted with two coat of synthetic enamel paint over a coat of red oxide primer after preparation of surface including locking arrangement and necessary excavation and earth work. Chamber foundation constructed with 80 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate over 100 mm thick hardcore using broken bricks aggregate in foundation and finished in cement mortar 1:6 and 15 mm thick cement plaster in cement mortar 1:4 in internal surface of wall and outside upto 150 mm deep upto ground level complete all specified and directed by Engineer-in-Charge.
(EXTERNAL ELECTRIFICATION) Shifting & Transportation of transformer step down 11 KV / 0.433 KV of 50 KVA capacity from store yard of AGE (AF) Bihta to the site of work at Darbhanga and Installation, connecting up, testing and commissioning of serviceable indoor transformer of Capacity 50 KVA, including heating, filteration and topping up of transformer oil (as required to achive desired level and die-electric strength of transformer oil), painting of transformer external surface with spray painting with two coats of syntethic enammel paint as per colour scheme approved by Engineer-in-Charge.
Supply, erecting, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 32 KW (40 KVA), at prime mover rating at 0.85 load factor as per Clause 13.3.2 of ISO-8528 (part-I), water cooled, 415 Volts (AC three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet , outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Dharbanga, Bihar( Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation( of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features to comply with latest CPCB guidelines and Comprising of followings:-
(i) ENGINE (Prime Mover): Diesel Engine 1500 RPM , direct injection ,multi cylinders ,four stroke, confirming to ISO3046/BS 5514, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering 40 KVA(32 KW) at outdoor atmospheric conditions at Dharbanga, Bihar, (Taking all derating factor into consideration), 12/24 Volt(as per manufacturer recommendations) electric battery start, complete withy dynamically balanced fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system(Shut down, High water temperature, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc. (ii) Alternator : Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 40 KVA/ 32 KW, Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class "H", salient pole, revolving field, single bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine.
(g) All standard relays, circuits and protection required for automatic operation of Gen set (h) By pass arrangment of suitable cap (V) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition and ox, 70DB at 3 M from Gen set when DG set is working at full load along with testing conformance, labeling certification etc as laid down in GSR No 371(E) dt 17 May 2002. (VI) Foundation/Plinth/Base: Shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the Set and height of plinth shall not be less than 0.5 M (VII) Diesel storage tank of capacity adequate for storage of diesel for 12 hours operation of Gen Set. (VIII) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. Make:- Engine - Kirloskar/Cumins, Alternator- Kirloskar/Stamford, Acoustic enclosure-Kirloskar/Jacksons. Note :- Testing clause of DG set by IEM during.
Note :- (i) The DG set shall be taken over only after it has been tested by the contractor in the presence of an officer nominated by the Accepting officer as per relevant IS specification/ Instruction. (ii) All the expenses incurred on the above test including provision of testing apparatus required to carry out the above mentioned test shall be born by the contractor without any extra cost to government. If the result of the test are not found satisfactory, the contractor shall at his own expense , replace the defective equipment/materials/ accessories or any thereof as directed by the Engineer in Charge. Decision of Accepting officer shall be final concusive and binding in this respect.
M&L for Boring of holes under road pavement, hard standing by trenchless lechnology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed
(ROAD PATH & CULVERT) Bringing Earth from out side MD land and spreading in layers n.exc 25 cm thickness including watering and rolling with 8 to 10 tone power roller complete all as specified and directed.
Lump sum price worked out by the contractor for completion of incomplete work in respect of M&L for construction RCC hume pipe culvert 600 mm dia pipe, class NP - 2 complete all as specified & as shown on drg. Note : (i) Approximate 20% work is balance at site. (ii) Please note that the quantities of balance work are not firm and the bidder shall assess his own quantities with reference to contract drawings and other conditions, after site visit before quoting the tender. Cost of any other items leftover with reference to contract drawings & conditions, and any other works required preparatory to complete the balance works shall be deemed to be included in the lump sum quoted for this item. Nothing extra shall be admissible on the ground of requirement of any other items or variation of quantities if any found at later stage.
M&L for applying bituminous premixed carpet 40mm thick (consolidated thickness) with 0.54 cum of stone chippings mixed with 29.20 Kg of paving bitumen VG-30 binder per 10 Sqm rolled and compacted to required camber and gradient with 8 to 10 tonne power roller complete all as specified and directed.
(SEWAGE DISPOSAL) Lump sum price worked out by the contractor for completion of incomplete work in respect of Construction of Brick masonary, septic tank of 100 user capacity all as specified and shown of drawings including earth work in any type of soil 100 mm bore cast iron inlet and outlet pipes upto 3.00 mtr from outer face of wall, including CI Tee, sluice valve chamaber, RCC slab and precast RCC manhole covers, reinforcement and CI vent pipes etc complete all as specified and as per drawing. Note : (i) Approximate 5% work is balance at site. (ii) Please note that the quantities of balance work are not firm and the bidder shall assess his own quantities with reference to contract drawings and other conditions, after site visit before quoting the tender. Cost of any other items leftover with reference to contract drawings & conditions, and any other works required preparatory to complete the balance works shall be deemed to be included in the lump sum quoted for this item. Nothing extra shall be admissible on the ground of requirement of any other items or variation of quantities if any found at later stage.
Lump sum price worked out by the contractor for completion of incomplete work in respect of Construction of soak well 2.4m dia and 4.5m effective depth including earth work in any type of soil foundation comcrete in PCC honey comb brick work, soild brick work in cement mortar, (1:4) RCC slab and precast manhole covers including reinforcement, with brick bats filling complete all as specified and shown on drg. Note : (i) Approximate 5% work is balance at site. (ii) Please note that the quantities of balance work are not firm and the bidder shall assess his own quantities with reference to contract drawings and other conditions, after site visit before quoting the tender. Cost of any other items leftover with reference to contract drawings & conditions, and any other works required preparatory to complete the balance works shall be deemed to be included in the lump sum quoted for this item. Nothing extra shall be admissible on the ground of requirement of any other items or variation of quantities if any found at later stage.
(COOLING APPLIANCES) Supply and fixing, wall mounted digital display voltage stablizer 5 KVA for automatic voltage correction, single phase, naturally air cooled indoor type designed for input voltage 170V to 250V with output voltage stabilized at 230V with accuaccy of + 2.5% with high/low voltage cut off with facility of time delay with overload and under voltage protection complete all as specified and directed. Make: V-Guard/Voltas/Sen & Pandit/AE
Supply and fixing, wall mounted digital display voltage stablizer 3 KVA for automatic voltage correction, single phase, naturally air cooled indoor type designed for input voltage 170V to 250V with output voltage stabilized at 230V with accuaccy of + 2.5% with high/low voltage cut off with facility of time delay with overload and under voltage protection complete all as specified and directed. Make: V-Guard/Voltas/Sen & Pandit/AE
Sabitri Jhunu Enterprise
NEHA INFRASTRUCTURE & COMPANY
United Sales Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .