Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC DH 101 DEEN DAYAL NAGAR MAHARAJPUR GWALIOR 474020 MP | GWALIOR | MADHYA PRADESH | 474020 | ₹1.5 Cr | L1 | Accepted-AOC AOC SINCE L1 |
| 2 | L2₹1.6 Cr+₹9.2 L (6.13%)Rejected-Finance | ₹1.6 Cr+₹9.2 L (6.13%) | L2 | Rejected-Finance REJECTED SINCE NOT L1 |
| 3 | L3₹1.6 Cr+₹15.2 L (10.1%)Rejected-Finance RAVI KIRAN MARKET JIWAJI CHOWK BADA LASHKAR GWALIOR M P 474001 | GWALIOR | GWALIOR | MADHYA PRADESH | 474001 | ₹1.6 Cr+₹15.2 L (10.1%) | L3 | Rejected-Finance REJECTED SINCE NOT L1 |
| 4 | L4₹1.7 Cr+₹21.3 L (14.2%)Rejected-Finance | ₹1.7 Cr+₹21.3 L (14.2%) | L4 | Rejected-Finance REJECTED SINCE NOT L1 |
Tender Value
₹2.3 Cr
EMD Value
₹3 L
Closing Date
14 Jul 2020, 6:00 pmClosed
CE AF ALLAHABAD
HQ CE AF ALLAHABAD
ADDL/ALTN TO CERTAIN TECHNICAL ACCNS AT AF STATION MAHARAJPUR
2020_MES_350200_1
958415/E8
Open Tender
Civil Works
Item Rate
365 days
Gwalior
As per NIT and tender document
8 documents required · 8 mandatory
₹2,000
Yes
GE (AF) (Tech area) Gwalior
₹3 L
Yes
29 Jul 2020
5 Jun 2020
21 Jul 2020
5 Jun 2020
14 Jul 2020
30 Jun 2020
6 Jun 2020 - 12 Jun 2020
Amount
Dismantling of Asbestos cement (corrugated , semi corrugated etc) sheets in roof covering including ridges fixed with L hook or cranked bolts complete all as specified and directed.
Demolition of levelling / padding course of plain cement concrete of any mix including bituminous felt / membrane from roof top including removal of debris out off the premises / MOD land complete all as specified & directed.
Demolition of plain cement concrete (unreinforced) of any mix / grade in ground floor and paving not exceeding 15cm thickness (below or above ground level) including removal of debris out off the AF station premises / MOD land etc complete all as specified & directed .
Demolition of reinforced cement concrete in slab, beams, chajjas, column & foundation (reinforcement cut as required to facilitate demolition) including removal of debris out off the premises / MOD land complete all as specified & directed.
Demolition of floor/wall tile and stone slab of any type / pattern including cement mortar bedding/backing and removal of debris out off the AF station premises / MOD land etc complete all as specified & directed .
Dismantling of brickwork of any description and in any position built in cement or cement lime mortar including removal of rubbish out off the AF station premises / MOD land etc complete all as specified and directed.
Taking down cement plaster from brick masonry wall surface & RCC ceiling etc including raking out joints in masonry, hacking for key & scrubbing down with water and removal of rubbish / mortar out off the premises / MD land etc complete all as specified & directed.
Taking down chowkats or frames with shutters exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frames) including builders hardware etc complete all as specified & directed.
Taking down chowkats or frames with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) etc including builders hardware etc complete all as specified & directed .
Dismantling of false ceiling of any type and pattern including wooden frame / grid work and cover fillets complete all as specified & directd.
Dismantling of mild steel work for trusses / purlin & grill / grating of any description complete all as specified & directed.
M&L for broken stone hardcore of gauge not exceeding 63 mm deposited, spread and leveled in layers not exceeding 15 cm thick watered and rammed to a true surface complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 27 cm deep and getting out in soft/ loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out in any type of soil including forming bottom surface to required slope/gradient for drain / electric cable etc complete all as specified & directed.
Excavation in post holes (or similar holes) n. exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm thick as in soft / loose soil incl watering & removing surplus soil material to a distance n.exc. 50 mtr & making good surface complete all as specified & directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing excavated soil not exceeding 50 metres & deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Removing excavated soil exceeding 250 metres but n.exc 500.00 metres & deposited where directed complete all as specified and directed.
M & L for providing and injecting chemical emulsion for Post Construction Anti-termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 Litres per linear metre including drilling and plugging holes of depth exc 30 CM but n.exc 45 CM etc in apron complete all as specified and directed.
M & L for post construction anti-termite treatment of soil under existing floors using chemical emulsion @ one litre per hole , placed 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors etc complete all as specified and directed.
M&L for PCC (1:4:8) type D-2, using 40 mm graded stone agrregate as in foundation and filling etc complete all as specified & directed.
M&L for PCC (1:3:6) type C-2 using 40 mm graded stone agrregate as in foundation and drain bed etc complete all as specified & directed.
M&L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregates in coping, block for fixing hold fast , roof kerb etc including use & waste of formwork & weathering, slightly rounded or chamfered angles & throating etc complete all as specified and directed.
M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggrgate) as in surface channel for area drain / manhole etc complete all as specified & directed.
M & L for 75mm thick PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in plinth protection laid in panels and joints filled with mix of bitumen and sand (1:3) by weight top surface finished even and smooth using extra cement complete all as specified and directed.
M&L for 100 mm thick PCC (1:4:8) type D-2 using 40 mm graded stone agrregate as in sub base , top surface finished rough to receive topping etc complete all as specified & directed.
M&L for 100 mm thick PCC (1:2:4) type B-1 using 20 mm graded stone agrregate as in hard standing, top surface finished by brooming etc complete all as specified & directed.
M & L for 25 mm thick PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggragate) as levelling course / padding laid over a neat cement slurry @ 3 kg per Sqm area on roof top using water proofing compound, surface finished even & rough to receive screed bed etc complete all as specified & directed. (Note:- WPC shall be measured and paid separately).
M&L for Cement concrete M-25 using 20 mm graded stone aggregate laid in path / hardstanding top surface finished by brooming complete all as specified & directed.
M&L for precast reinforced cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) in cover slab for manhole and wash hand basin platform including setting in cement mortar 1:4 & use of necessary forwork etc complete all as specified and directed. (Note: Reinforcement shall be measured and paid separately)
M & L for reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregates) in foundation, footing etc complete all as specified & directed. (Note: Reinforcement and Formwork shall be measured and paid separately under respective items.)
M&L for Reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregates) in columns etc complete all as specified and directed. (Note:- Reinforcement and formwork shall be measured and paid separately under respective items)
M & L for reinforced cement concrete (1:2:4) type B-1(using 20 mm graded stone aggregates) in beam, lintle etc complete all as specified & directed. (Note: Reinforcement and Formwork shall be measured and paid separately under respective item.)
M&L for Reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregates) in chajja etc complete all as specified and directed. (Note:- Reinforcement and formwork shall be measured and paid separately under respective items)
M&L for Reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregates) in slab suppoted on walls etc complete all as specified and directed. (Note:- Reinforcement and formwork shall be measured and paid separately under respective items)
M&L for form work to sides of concrete foundations, footings, bases of columns, sides & soffits of plinth beams and similar work for rough finished flat surfaces of concrete etc complete all as specified and directed.
M&L for form work to sides of square or rectangular column and stanchions for rough finished surfaces of concrete etc complete all as specifed & directed.
M&L for form work to sides and soffits of floor or roof beam for rough finished surface of concrete etc complete all as specifed & directed.
M&L for form work to sides and soffits of chajjas and other similar works for rough finished surface of concrete etc complete all as specifed & directed.
M&L for form work to soffits of suspended slab such as roof slab , floor slab and similar works for fair finished surface of concrete etc complete all as specifed & directed.
M&L for form work to edges of conrete flat in slab, chajja exc 10 cm but n.exc. 20 cm thick and similar works for rough finished surface of concrete etc complete all as specifed & directed.
S&F TMT bars 10mm dia and over , cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed.
All as per Srl item No. 1.42 but 6 mm to 8 mm dia bars.
All as per Srl item No. 1.42 but 8 mm dia TMT bars in stirrups, spacers & binders.
M&L for mild steel framed work such as grills, grating etc with ends of bars shouldered and or reveted into spikes, framed guard bars, , barred iron doors, ladders, framed balusters, walk ways, railing, cooler platform, frame work of water tanks and similar work including welding conforming to Fe-290 & grade E-165 etc complete all specified and directed.
S&F steel tubular truss & post using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete including special shape washers necessary welding, nuts and bolts complete all as specified and directed.
S & F rolled sections, plates in framed roof trusses, purlin etc of grade Fe 410 - W (Gde E-250) quality A including welding etc complete all as specified & directed.
Supply only MS screw bolt (machine made) of 11 to 15 mm dia with hexagonal or square head one end and screwed the other or screwed both ends, each screw end to be fitted with washer and one hexagonal or square nut, length of bolt n.exc 5 cm long etc complete all as specified & directed.
M&L for Brick work using old size fly ash bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified & directed.
M&L for Brick work using old size fly ash bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 complete all as specified & directed.
S & F Solid PVC door frame of size 50mmx 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube, as per manufacturers specification complete all as specified and directed.
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and as gap insert for top rail & bottom rail. Paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent complete all as specified and directed.
S&F stainless steel butt hinges of 100 mm size medium weight etc complete all as specified and directed.
S&F stainless steel decorative handles glossy finish of approved pattern & type of 150 mm size complete all as specified and directed.
S&F stainless steel bright finished tower bolts of approved pattern of 150 mm long complete all as specified & directed.
S&F stainless steel 300 mm size sliding door bolt with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections & fixing bolt & sliding bolt of extruded section for door shutter complete all as specified & directed.
S&F extruded aluminium body door closure hydraulically regulated designation No. 3, universal type, suitable for door shutter of 851 to 1000 mm width and weight between 61 to 80 Kg and fixed in position complete all as specified & directed.
S&F mortice lock with handle vertical type of size 65 mm four levers complete all as specified and directed.
M&L for double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of aluminium & other parts made of mild steel heavy duty fixed concealed in floor including cutting of floor and making good disturbed floor complete all as specified and directed.
S&F powder coated of approved tint aluminium door with door frame of size 100 mm X 44 mm X 2.5 mm thick and shutter with style of size 85 mm X 44 mm X 25 mm thick and rails 110mm X 44mm X 2.5mm thick including 6 mm thick sheet glass and partly/ fully fixed with 12 mm thick both side prelaminated exterior grade particle board fixed with aluminium snap beading and rubber gasket. The each shutter fitted with one aluminium sliding bolt of 250 mm , 02 Nos tower bolt 200 mm , 02 Nos disc handle and one hydraulic floor spring complete all as specified & directed.
S&F powder coated ( of approved tint ) aluminium deco grill of size 4 mm X 4mm , 8 mm thick and aperature n.exc 80 mm width including fixing with 1 mm thick aluminium channel with steel screw complete all as specified & directed
M&L for non skid rectified edges (joint free) coloured ceramic floor tiles not less than 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.11 Sqm but not exc 0.18 Sqm, set & jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles laid over & including 15 mm thick screed bed in CM(1:6) over 25 mm thick levelling course of PCC 1:2:4 type B-0 using 12.5 mm stone aggregate etc complete all as specified & directed.
M&L for glazed ceramic coloured wall tiles of size 450X300mm not less than 7 mm as in skirting / dado etc set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles including 10 mm thick backing coat in CM (1:4) etc complete all as specified & directed.
M&L for Vitrified dark shade, coloured floor tiles not less than 10 mm thick (Square/rectangular) area of each tile exc 0.18 Sqm but not exc 0.36 Sqm, set & jointed in neat cement slurry and pointed in coloured cement to match the shade & tiles laid over & including 15 mm thick screed bed in CM(1:6) over 25 mm thick levelling course of PCC 1:2:4 type B-0 using 12.5 mm stone aggregate etc complete all as specified & directed.
M&L for Vitrified dark shade, coloured tiles not less than 10 mm thick (Square/rectangular) area of each tile exc 0.18 Sqm but not exc 0.36 Sqm, in skirting to match floor tiles set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over & including 10 mm thick backing coat in CM (1:4) etc complete all as specified & directed.
M&L for machine cut kota stone slab flooring 22 to 25 mm thick of size not less than 575 mm X 575 mm set & jointed with grey cement slurry and pointed with coloured cement to match the shade of the slab including grinding, rubbing & polishing laid over & including 20 mm thick screed bed in CM (1:6) over leveling course 25 mm thick in PCC 1:2:4 type B-0 using 12.5 mm stone aggregate etc complete all as specifed & directed.
M&L for machine cut kota stone in skirting 22 to 25 mm thick set and jointed with grey cement slurry & pointed with coloured cement to match the shade of the slab including rubbing & polishing & laying over & including 10 mm thick backing coat in CM (1:4) etc complete all as specifed & directed.
M&L for 100 mm wide Makrana white Marble strip 18 to 20 mm thick laid as border in flooring, set & jointed in neat cement slurry & pointed in white cement to match including grinding, rubbing & polishing, laid over and including 20 mm thick screed bed in CM(1:6) over a leveling course of 25 mm thick in PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate etc complete all as specified & directed.
M&L for 18 to 20 mm thick granite slab Jet black or Telephone black in single piece table rubbed and pre mirror polished top & half moulded prepolished visible edges ( to match the top ) as in wash hand basin platform set & jointed in neat cement slurry & pointed in coloured cement to match the shade of granite over & including 20 mm thick screed bed in cm (1:4) and drilling holes for out let pipe etc complete all as specifed and as directed.
M&L for 18 to 20 mm thick granite slab Jet Black or Telephone black,table rubbed and both side pre mirror polished in single piece as partition for urinals set ,embeded in the wall & jointed in neat cement slurry & pointed in colour cement etc complete all as specifed and as directed.
S&F 4.50 mm thick plain coloured linoleum, laid in floors including stretching, cutting and sealed down with an approved adhesive executed through approved applicator as per manufacturer's recommendations complete all as specified & directed
M & L for forming contraction(dummy) joints 10 mm wide and 65mm deep filled with sealing compound grade 'A' complete all as specified and directed
M & L for forming contration/dummy joint with diamond cutter to a depth of 65 mm and 10 mm wide , primed and providing a 10 mm dia polyethylene back up rod and top 10 mm primed and sealed with and using polyurethane based sealing compound ( polyurethane joint sealant) with suitable primer as per manufacturer's recommendations complete all as specified and directed.
M&L for forming 25 mm wide expansion joints to full depth(n exc 150 mm) of pavement concrete slab and primed and filled with compressible closed cell premoulded high performance joint filler board HD-100 (Sil Flex Dura board HD 100 of Supreme make or equivalent) and provision of closed cell polyethylene back up rod 30 mm dia , and top 10 mm primed and sealed with and using polyurethane based sealing compound (Polyurethane joint sealant) with suitable primer as per manufacturer's recommendation complete Note : (i) Cost of joint filler board shall be deemed to be included in the quoted rate.
S&F Pre-painted galvalume aluminum zinc coated corrugated sheet 0.50mm thick of approved colour having tensile strength 550 Mpa in roof covering including ridges & valley fixed with self tapping screws complete all as specified& directed
S&F Pre-painted galvalume aluminum zinc coated plain sheet 0.50mm thick of approved colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screwes complete all as specified& directed
M & L for 15 mm thick screed bed in CM (1:4) over roof top (Using liquid water proofing compound ) surface finished even and smooth using extra cement and application of water proofing treatment using APP modified roof membrane over existing accessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying oil bound bitumen primer @ 0.40 litre/Sqm manufactured by the same agency as that of APP membrane with a density 0.87-0.89 Kg per litre at 25 degree centigrade on prepared surface. (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gms/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Physical property of membrane shall be as under :- (i) Membrane weight not less than 3.60 Kg/Sqm. (ii) Non woven polyester weight not less than 160 gsm/Sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650/Sqcm and transverse not less than 450/sqcm at 230 degree Celsius. (v) Tear strength - longitudinal not less than 300 N & transverse not less than 250N. (vi) Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3 Kg/Sqcm. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap. . (Note:- WPC shall be measured & paid separately)
M & L for laying 40 mm thick brick tile laid over 20 mm screed in cement mortar 1:4 mixed with WPC and tiles jointed with approved polymer based water proof joint filler etc complete all as specified & directed. (Note:- WPC shall be measured and paid separately)
Supply only liquid water proofing compound of approved make all as specified & directed.
M&L for providing Gypsum board 12 mm thick (semi perorated) in ceiling fixed with screw as per manufacturer's instruction on existing snap grid system complete all as specified & directed.
S&F MS galvanised powder coated suspended false ceiling system with grid size 605 mm X 605 mm consisting of mild steel galvanised powder coated main runner of size 24 mm x 32 mm and cross Tee of size 24 mm x 27 mm and wall angle of size 22.2 mm X 22.2 mm, suspended with 4 mm dia GI wire hanger at 1200 mm spacing , fixed with steel dash fasteners or from purlin of roofs with butterfly clips etc at approx 8.50 metre height from FFL including 12 mm thick gypsum board (semi perforated) in ceiling fixed to GI snap grid frame work with screws including making provision for housing light fitting, AC grills etc complete as per manufacturer instruction complete all as specified & directed.
S&F 30 mm thick PU (Polyurethane) Foam filled composite insulated roof sheeting made out of external skin of prepainted galvalume aluminium zinc coating corrugated 0.4 to 0.5 mm thick sheet and internal skin of 0.3 to 0.4 mm thick sheet of approved colour having tensile strength 550 Mpa fixed with self tapping screw all as specified & directed.
M&L for rendering 5 mm thick in CM (1:3) on concrete ceiling,surface finished even and smooth using extra cement complete all as specified & directed.
M&L for rendering 15 mm thick in CM(1:6) on other than fair faces of brick masonry wall or concrete, surface finished even and smooth using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick in CM(1:4) on fair faces of brick masonry wall or concrete surfaces of area drains & manholes etc surface finished even and fair complete all as specified and directed.
M&L for rendering 15 mm thick in CM (1:4) on fair faces of brick masonry wall or concrete surfaces using WPC (liquid type), surface finished even and smooth using extra cement all as specified and directed. (Note: WPC will be paid separately under respective item)
M&L for preparation of existing white washed surface of ceiling and applying one coat of white wash on ceiling complete etc all as specified & directed.
M&L for preparation of newly plastered surface and applying three coat of white wash in ceiling complete etc all as specified & directed.
M&L for preparation of existing white washed surface of ceiling by complete removal of existing treatment with rotary scrapper to achieve periodicals free plastered surface and applying two coats of white wash on ceiling over & including a layer of wall care putty of thickness not less than 1.5 mm & not exceeding 2 mm etc complete all as specified & directed.
Preparation of newly plastered surfaces of wall and apply two coats of distemper oil emulsion (OBD) with roller finish over a coat of cement wall primer (from same manufacturer of OBD) over and including a layer of wall care putty of thickness not less than 1.5 mm & not exceeding 2 mm etc complete all as specified and directed.
Preparation of existing distempered surfaces of walls by complete removal of existing treatment with rotary scrapper to achieve paint/ periodicals free plastered surface and applying two coats of distemper oil emulsion (OBD) with roller finish over a coat of cement wall primer (from same manufacturer of OBD) over & including a layer of wall care putty of thickness not less than 1.5 mm & not exceeding 2 mm etc complete all as specified and directed.
Preparation of newly plastered external surfaces of wall including cornices pilasters and apply two coats of exterior emulsion paint of approved brand and shade with roller finish over and including one coat of alkali primer all as per manufacturers instructions over a layer of wall care putty of thickness not less than 1.5 mm and not exceeding 2 mm including necessary scaffolding etc complete all as specified and directed.
Preparation of existing external wall surface by complete removal of existing treatment with rotary scrapper to achieve paint/ periodical free plastered surface and applying two coats of exterior emulsion paint of approved brand and shade with roller finish over one coat of alkali primer all as per manufacturers instructions over and including a layer of wall care putty of thickness not less than 1.5 mm thick & not exceeding 2 mm including necessary scaffolding etc complete all as specified and directed.
M&L for prepartion of existing painted steel surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified & directed.
M&L for prepartion of new or previously untreated steel surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed.
S&F 4 mm thick sheet glass, ordinary quality fixed with oil putty in squares/ rectangles, not exc. 0.5 Sqm in each pane including hacking out existing broken glass complete all as specified & as directed.
S&F 5.5 mm thick tinted sheet glass, fixed with & including rubber beading in squares/ rectangles exc. 0.5 Sqm in each pane including hacking out broken glass & rubber beading etc complete all as specified & directed.
S&F self adhesive sun control film 50 micron thick non- reflective type sticked to glass panes as per manufacturer's instructions complete all as specified and directed.
S&F GI water tubing medium grade, ISI marked, 15 mm bore concealed with all fittings (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors including taking up or down existing tubing & cutting chases & making good surface in cm (1:3) complete.
S&F GI water tubing medium grade, ISI marked, 20 mm bore concealed with all fittings (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors including taking up or down existing tubing & cutting chases & making good surface in cm (1:3) complete.
S&F in repair 15 mm bore bib taps, cast copper alloy with capstan head, CP fancy type with long body shank, & wall flange, high pressure screwed down for iron pipe complete all as specified & directed.
S&F in repair 15 mm bore pillar taps fancy type, cast copper alloy with capstan head, chromium plated,screwed for iron pipe complete all as specified & directed.
S&F in repair concealed cast copper alloy angular 15 mm bore stop cock fancy type,chromium plated, high pressure screwed both ends complete all as specified and directed.
S & F 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S & F 15 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repairs viterous china wash down water closet pan (padestal pattern), white with and including plastic water closet seat in white colour closed pattern with flat bottom, mild steel chromium plated or aluminium hinging device including fixing bolts & outlet connection etc complete all as specifed & directed.
S & F in repair viterous china urinal full bowl type, white including fixing plugs bedding urinal against wall in CM (1:2) securing urinal to plug with and including 60 mm brass screw, pointing around urinal back in cement including chromium plated cast copper grating and union & 32 mm dia PVC discharge pipe complete all as specified and directed.
S&F in repair Viterous china counter top ovel shaped wash hand basin of approx size 510X450 mm of white colour as per cat part No. 10038 of Hindware or equivalant including cast copper alloy waste coupling , PVC connection 15 mm bore 450 mm long with PTMT nuts and PVC 32 mm bore waste pipe complete set all as specified and directed.
S&F in repair PVC flushing cistern 10 ltr capacity dual mode valve less syphonic action type low level with and incl ball valve float and handle, PVC flush pipe 32 mm dia & PVC connection 15 mm bore 450 mm long with PTMT nuts and brackets etc complete set all as specified and directed.
S&F kitchen sinks with draining board made of stainless steel 1 mm thick with plugs, washers & waste coupling and waste pipe, including bedding in cement mortar 1:2 on dwarf wall or fixing on cantilever brackets, waste coupling, connecting union, 32 mm dia PVC outlet pipe overall, size 915 mm X 460 mm and bowl size 410 mm X 330 mm X 160 mm complete all as specified and directed.
S&F PVC connection 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed.
S & F toilet paper holder, viterous china, box type coloured all as specified and directed.
S&F in repair 32 mm bore cast copper alloy chromium plated bottle trap for wash basin with inlet and outlet screwed for pipes or connection including necessary packing union cap complete all as specified and directed .
S&F in repair soap dish of viterous china, white of size 160 mm x 160 mm x 190 mm embedded in wall set & pointed in cm 1:2 complete all as specified & directed.
S&F chromium plated brass tubular towel ring 200 mm dia fixed with CP screw on wall complete all as specified and directed.
S&F in repairs CP towel rack 600 mm long with lower hangers fixed with CP screw on wall complete all as specified and directed.
S&F in repair sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide & 60 cm long with cast copper alloy chromium plated bracket and railing as per approved pattern complete all as specified & directed.
S&F in repair cast copper alloy chromium plated health faucet of make Jaguar Cat Part ALDCHR565 or equivalent from plumber, Marc or Prayag including 1 M long easy flex tube & hook complete all as specified & directed.
S&F 100 mm dia cast iron floor trap set in cement concrete 1:2:4 type B-1 (using 20 mm stone aggregate) including connection to waste pipe & PTMT grating doom (minimum weight 25 gm) complete all as specified & directed.
S & F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall with GI flat iron including taking down of existing rain water pipe complete all as specified and directed.
S & F 160 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall with GI flat iron including taking down of existing rain water pipe complete all as specified and directed.
S & F 110 mm dia PVC(SWR) bends any radius complete all as specified and directed.
S & F 160 mm dia PVC(SWR) bends any radius complete all as specified and directed.
S & F 110 mm dia PVC (SWR) vent cowl complete all as specified and directed.
S & F 160 mm dia PVC (SWR) Junction single (Single T) equal or unequal complete all as specified and directed.
S&F rotational moulded polythene water storage tank of capacity 1000 ltrs (Cylindrical/vertical with closed type), triple layer construction, ISI marked, hoisted and fixed in position including 20 mm bore ball / float valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe (minimum weight 210 gm) & 20 mm bore GI medium grade over flow pipe ( 450mm long) and washout pipe (600 mm long )with fittings including dismanling of existing tank of any type & capacity and lowering down etc complete all as specified and directed.
S&F in repairs Steel rolling shutters gear operated type with bevel gear box & crank handle fabricated with 1.25 mm thick lath including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position all as specified & directed.
Repair, maintenance of existing rolling shutter of any pattern & type of height not exc 4.5 mtr without taking down but removing hood cover ascertaining serviceability of existing parts & taking out unserviceable parts and replacement with new one, fixing the existing serviceable parts in their position for ensuring smooth functioning of the rolling shutters including greasing, oiling etc and replacemen of nut, bolts, washers including necessary welding, reveting etc complete all as specified and directed . Note: Spairs/ parts to be replaced shall be measured and paid as suply only under respective items however fixing charges included in the unit rate.
Supply only flat spring suitable for rolling shutter upto 4.5 M height (spring wt not less than 7 Kgs each)
Supply only MS spring wheel of any size with MS bush fixed with shaft for rolling shutters complete all as specified and directed.
Supply only ball bearing for rolling shutter.
Supply only Saftey lever lock of mild steel 4 levers for rolling shutter.
Supply only 40mm dia (nominal bore) medium weight mild steel pipe as suspension shafts complete all as specified and directed.
Supply only hood covers made out of 1.0mm thick mild steel plain black sheet, cut to size & shapes, punched and spot welded including bending or turning, mitred single etc as required complete all as specified and directed.
Supply only fabricated bracket plate of mild steel sheet 3.15 mm thick as per IS for height upto 4.5 M of shape matching with existing not exceeding 0.5 Sqm for mechanically operated rolling shutter complete all as specified & directed.
S&F roof mounted wind (turbo) ventilator of make Mukta Engineers, Kalyan 421301 or equivalent having 600 mm dia bottom ring 500 mm dia top ring & height 420 mm made up of stainless steel & aluminium vanes with two ball bearings fixed on roof sheeting with appropriate size FRP base plate all as per manufacturers instructions complete all as specified & directed.
M&L for 3 mm thick frosted Matt acrylic plexiglass DIV project fixed in ventilators / window with aluminium frame work complete all as specified & directed. Make :- BIGMALL or equivalent
M&L for 150 mm bore Reinforced Concrete Pipe, class NP2, laid in trenches and jointed in cement mortar 1:1 with collars etc complete all as specified and directed.
M&L for concrete bed 100 mm thick for 150 mm bore drain pipe in plain cement concrete 1:3:6, type C-2 (using 40mm graded crushed stone aggregate) including packing under and haunching against the sides of pipes after they are laid on slope, jointed and tested etc complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
Add or deduct item No. 2.42 For each 25 mm girth over and under 30 mm or part there of complete all as specified and directed.
Construction of Brick masonary( with old size fly ash bricks), septic tank of 10 user capacity all as specified and shown on drawings including earth work in any type of soil 100 mm bore cast Iron inlet and outlet pipes upto 3 mtr from outer face of wall, including CI Tee, sluice valve chamber, RCC slab and precast RCC manhole covers, CI vent pipes etc complete all as all as shown on TD Drg No. TD/217 Sheet No. 1/2 & 2/2 & specified.
M&L for provision of soakage wells of size 1.2 M dia & 3 Metre deep including excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonary with top ring M-25 concrete including intercepting chamber and screen chamber made of brick masonary in CM, RCC cover slab in M-25 (Using 20 mm graded stone aggregate ) cover, interconnecting pipes of RCC complete filled with brick bats etc complete all as shown on TD Drg No. CELZ/TD/576 Sheet No. 1/2 & 2/2 & specified
Taking down carefully unsv/damaged copper/aluminium surface (batten/coduit or casing caping) or concealed point wiring / flame proof point wiring of any length for light/fan/socket or power including unscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets, Bracket /sketch fitting etc) and sunken junction boxes including making good to the disturbed surface etc complete all as specified and directed.
Point wiring using FRLS PVC insulated unsheathed /multi stranded copper conductor cable & earth wire cable both of 1.5 sqmm single core drawn through & including surface PVC conduit on wall / ceiling of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bend, junction box and pressed steel sunken box 60 mm deep & 1.6 mm thick duly painted inside and anticorrosive out side for mounting switches, sockets, fan regulators etc with 3mm thick plastic laminated sheet cover of suitable size, connecting earth wire to earth dolly, including cutting nitch for fixing sunken boxes & , making good to disturb surface of wall with cement mortar (1:4) including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type etc for light/fan point etc complete all as specified and directed. (Note : Switch/fan regulator etc shall be measured and paid separately)
Point wiring using FRLS PVC insulated unsheathed /multi stranded copper conductor cable & earth wire cable both of 1.5 sqmm single core drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bend, junction box and pressed steel sunken box 60 mm deep & 1.6 mm thick duly painted inside and anticorrosive out side for mounting switches, sockets, fan regulators etc with 3mm thick plastic laminated sheet cover of suitable size, connecting earth wire to common earth dolly, including cutting groove for concealed wiring, refilling disturb surface of wall with cement mortar (1:4) including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type etc (Conduit shall be fixed on surface of ceiling with necessary saddles where concealing of conduit is not feasible), for light/fan point etc complete all as specified and directed. (Note : Switch/fan regulator etc shall be measured and paid separately)
All as per Srl item No. 2.48 above but for one 5 pin 5 Amp concealed socket outlet point on independent board controlled by one switch 5Amp, one way, etc complete all as specified and directed.
All as per Srl item No. 2.48 above but for one 15 Amp socket outlet point concealed using cable & earth wire both of 2.5 Sqmm FRLS PVC insulated unsheathed multi-strand copper conductor on independent board controlled by one switch 15 Amp etc complete all as specified and directed.
All as per Srl item No. 2.48 Above but for flame proof point on wall / ceiling / steel structures upto a height of 10 mtr wiring using FRLS PVC insulated, unseathed multistranded copper conductor cable & earth wire both of 1.5 sqmm single core 1100 volt grade drawn through and including concealed ERW steel conduit not less than 19 mm dia with fixing accessories like clamps etc and conduit accessories including welding for light/fan point etc complete all as specified & directed. Note :- (i) Flame proof switch shall be measured & paid separately. (ii) All steel conduit accessories such as bends, elbows, Tee, reducers, junction box etc deemed to be included in the rate quoted. (iii) where it is not feasible to cut groove in RCC slab/steel members, conduit shall be fixed on surface with clamps.
All as per Srl item No.2.48 above but for one 15 Amp flame proof socket outlet point concealed using cable & earth wire both of 2.5 Sqmm FRLS PVC insulated unsheathed multi-strand copper conductor on independant board controlled by one switch 15 Amp etc complete all as specified and directed.
All as per Srl item No.2.48 above but for one 20 Amp flame proof socket outlet for AC point concealed using cable & earth wire both of 4.0 Sqmm FRLS PVC insulated unsheathed multi stranded copper conductor on independant board controlled by one switch socket & plug combination complete all as specified and directed.
S&F switch socket outlet combination, five pin, 5 Amps flush type, 230 volts AC circuit ISI marked complete all as specified and directed.
S&F switch socket outlet combination ISI marked multipurpose , three pin, 15 Amps & 3 pin 5 Amps, flush type 230 volts AC complete all as specified and directed.
S&F ceiling rose, surface bakelite not less than 50 mm X 20 mm AC, 230 V polycorbonate isolated body, ISI marked two or three terminals complete all as specified and directed.
S&F switch piano, flush type, single pole, one way 5/6 amps 230 volt AC ISI marked complete all as specified and directed.
S & F single pole and neutral sheet metal enclosure with two pin and earth plug and socket complete with one MCB single pole, 240 V, of capacity 20 Amps complete all as specified and directed.
Supply, fixing, connecting & testing of sheet metal enclosures for DB double door, triple pole and neutral, 415 V, 4 way having aluminium bus bars suitable for 200 Amps rating with all fitting & fixtures fixed concealed including disconnecting and taking down unserviceable distribution board complete all as specified and directed.
S & F MCCB FP, 100 Amps, 50 Hz, 415 Volt with rupturing capacity 16 KA complete all as specified and direced.
S & F MCCB FP, 63 Amps, 50 Hz, 415 Volt with rupturing capacity 16 KA complete all as specified and directed.
S & F MCB TPN, 63 Amps (`C’ series), 50 Hz, 415 Volt with breaking capacity 10 KA complete all as specified and directed.
S&F MCB two pole, 32 Amps (`C’ series), 50 Hz, 415 Volt with breaking capacity 10 KA complete all as specified and directed.
S&F MCB single pole, 6 to 32 Amps (`C’ series), 50 Hz, 230 Volt with breaking capacity 10 KA complete all as specified and directed.
S&F MCB SPN, 40 Amps (`C’ series), 50 Hz, 230 Volt with breaking capacity 10 KA complete all as specified and directed.
Supply & fixing decorative ultra slim linear LED tube light fitting 01 x 20-25 watt lighting fixture with co-extruded polycarbonate body, environmental friendly, energy efficient ready to use pack with all accessories including 01 No 20 watt tube rod and connecting the same to ceiling rose using copper conductor 23/0.0076 flexible PVC sheathed and insulated three core copper conductor cable including all accessories and fixing arrangement for fixing the light fitting to walls/roof surface complete all as specified & directed, Make - Havells Cat Part No. LHEWEBP5INIWO20 , Philips, Cat No. BN 021 LED25S 6500 PSU GR S1, Bajaj Cat Part No. BCLSBAL 20 W CW.
S & F LED mirror light fitting 1x9/10 watt with LED tube rod including electrical connections complect all as specified and directed, Make - Havells Cat Part No. ENDURA LINEAR NEO BS 10W LED 830 SPC WH or CG Cat Part No. LCTL-9-CDL or Bajaj Cat Part No. BCLSB 10 WH
Supply & fixing decorative recessed mounting 36 watt LED full out put luminaries suitable for fixing in false ceiling, white powder coated sheet steel housing with paralite P5 square parabolic louver block in metallic perforated frame for low glare, aluminium reflector and accessories,connecting the same to electric source with and including copper conductor 23/0.0076 flexible twisted twin core cable, including all accessories and fixing arrangements for fixing the light fitting to false ceiling complete all as specified and directed, Make - Bajaj Cat Part No. BZRSQL 36W GZ1 NW "SKYLUX' Recess mounted 2x2 LED , CG Cat Part No. LCPL-36-CDL(2x2) ,Havells Cat Part No.ENDURASLIMPROPLUS2X2PLR28/36WLED857MOD.
Supply, fixing, connecting and testing in repair 120-140 Watts, LED Highbay luminaire, having ventilation technolagy for better thermal management and its cutting edge LED technolagy seeks various industrial applications including mounting bracket, coupler with and connecting the same to electric source using copper conductor 23/0.0076 PVC insulated flexible three core cable, all accessories and fixing arrangements i.e. nuts, bolts, washer etc for fixing the light fitting to ceiling in high rise buildings/hangers complete all as specified & directed, Make - Bajaj, Cat Part No. BGHB 120W LED GIV or Havells, Cat Part Nos. SAUCERNEOP120WLED75790DLTG / SAUCERNEOP120WLED75760DLTG or CG Cat Part No. LHB-140-CDL/60.
S & F LED street light fitting 45 watt made up of pressure dia cast housing with toughned glass and individual LEDs with secondry optics and IP66 protection accessories with connecting the fitting to electric source with using copper conductor 23/0.0076 flexible twisted twin core cable, including provision of single arm/bracket made out of 40mm bore light grade GI pipe (1.2 metre long) bend to angle of 120 degree & fixed on wall / pole with two mild steel 40 x 3 mm flat iron clamps.Clamps shall be painted with two coat of aluminium paint over a coat of red oxide primer including taking out existing street light fitting with bracket complete all as specified and directed. Make :- Bajaj Cat Part No BRTFG 45W LED WW or Havells Cat Part No. ENDURAPEARLNEOSL45WLED757SASYTOPC or CG Cat Part No. LSTP-45-CDL.
Supply and fix exhaust fan of 450mm sweep (heavy duty), minimum BEE 3 star rated, single phase, 230 V, AC , 1440 RPM, MS powder coated body & mounting frame with louvered shutters including nut , bolts, washers, fasteners etc including making suitable size hole in brick masonry for fixing of exhaust fan and connection to ceiling rose with stranded copper conductor 23/0.0076, three core , pvc insulated flexible cable not less than 0.5 mtr long & testing etc complete all as specified & directed.
Supply and fix exhaust fan of 300mm sweep (heavy duty), minimum BEE 3 star rated ,single phase, 230 V AC , 1440 RPM, MS powder coated body & mounting frame with louvered shutters including nut , bolts, washers, fasteners etc including making suitable size hole in brick masonry for fixing of exhaust fan and connection to ceiling rose with stranded copper conductor 23/0.0076, three core ,pvc insulated flexible cable not less than 0.5 mtr long & testing etc complete all as specified & directed .
Taking down exhaust fan, single phase with louvers, 230 volt, 450 mm sweep from the existing position refixing at new position by cutting suitable size hole in brick masonry electrically connecting & testing including closing of existing hole with brick masonry built in cement morter (1:4) including making good disturbed surfaces of old & new locations to match with the existing surfaces & finishes and removing spoil at a distance not exceeding 50 mtr from the site, fixing & grouting of frame complete all as specified and directed.
Supply and fix wall mounted fan 450 mm sweep having oscilating motion and speed control facility with accessories 230 V, single pole and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified & directed.
Taking down by electrically disconnecting ceiling fan of any sweep removing blades / cap & preparing surface, filling cavities with filler & spray painting fans with synthetic enamel paint reassembling greasing/oiling and reconnecting electrically including testing etc complete all as specified and directed.
S&F fan regulator electronic, step type, hum free, socket type , suitable for ceiling fans of any sweep 230 volts AC 50 HZ supply 100/120 Watt complete all as specified & directed.
S & F flame proof push button rotary type switch 16 Amps in LM 6 metal enclosures, conforming to Cat Part No. PBS / OA /1010-1A of Make - Sudhir or equivalent from Baliga / Prateek Explosion Pvt. Ltd. complete all as specified & directed
S & F flame proof switch socket & plug combination made of aluminum alloy LM-6 having 2 pole + earth suitable for 250 volts supply and current rating of 16 Amps complete all as specified & directed, Make - Sudhir, Cat Part No. SS/OA/1010 -1 or equivalent from Baliga / Prateek Explosion Pvt. Ltd.
S & F flame proof switch socket & plug combination made of aluminum alloy LM-6 having 2 pole + earth suitable for 250 volts supply and current rating of 25 Amps complete all as specified & directed for AC, Make - Sudhir Cat No. or equivalent from Baliga / Prateek Explosion Pvt. Ltd.
S & F flameproof distribution board 8 way single pole & neutral in LM-6 metal enclosures 240 Volt complete all as specified and directed, Make - Sudhir, Cat Part No. MCB DB-186 or equivalent from Baliga / Prateek Explosion Pvt. Ltd.
Supply & fix flame proof distribution board 4 way triple pole & neutral in LM-6 metal enclosures , 415 Volt complete all as specified and directed, Make - Sudhir, Cat part No. MCB DB-186 or equivalent from Baliga / Prateek Explosion Pvt. Ltd.
Supply & fix CMRI certified LED flameproof 1x16/20W/22W tube light fitting conforming to IS : 2148 / 1981 & 2206 (Part-I )1984, Temperature class T-4, & made of cast aluminum alloy LM-6 having inside & outside light grey powder coating shade No 631 as per IS: 5 & one No internal earthing terminal and 02 Nos external earthings of screw of M6- size with 02 Nos plain washers, heat resistant glass complete all as specified and directed. Make : Crompton Cat Part No. EXTN1LT8-16/20 or equivalent from Sudhir /Baliga.
S & F in replacement flame proof FLP Flood light 120 W LED fittings conforming to IS : 2148 / 1981 & 2206 (Part-I )1984, temperature class T-4, made of cast aluminum alloy LM-6 having inside & outside light grey powder coating shade No 631 as per IS: 5 & one No. internal earthing terminal and 02 Nos. external earthings of screw of M6- size with 02 Nos. plain washers, heat resistant glassetc complete all as specified and directed. Make : Sudhir Cat Part No. FL/2C/1251 or equivalent from Baliga/Crompton.
S & F in replacement flame proof FLP Well glass light 72 W LED or next higher size fittings conforming to IS : 2148 / 1981 & 2206 (Part-I )1984, Temperature class T-4, & made of cast aluminum alloy LM-6 having inside & outside light grey powder coating shade No 631 conforming to IS: 5 & one No. internal earthing terminal and 02 Nos. external earthings of screw of M6- size with 02 Nos. plain washers, heat resistant glass complete all as specified and directed. Make : Sudhir, Cat Part No FL/2C/1239 or equivalent from Baliga/Crompton.
Supply and fixing flame proof exhaust fan with FLP louvers 457mm (18 Inch) sweep, 230 volt, AC, SP 1440 RPM and connecting the same to electric source using copper conductor 23/0.0076 PVC insulated flexible three core cable including testing ccomplete all as specified and directed, Make - Sudhir Cat Part No.EF-140 or equivalent of Baliga/Baldev Electric Works/Shyam Airetric Controls.
M&L for Sub main wiring with FRLS PVC insulated unsheathed 2X6 sqmm multistranded copper conductor cable 1100 V with 1X6 sqmm FRLS PVC insulated green multistranded copper cable for continuous earth drawn through & including concealed steel conduit of appropriate size not less than 19 mm dia & 1 mm wall thickness with all accessories including cutting grooves and making good disturbed surface including taking down existing surface submain wiring etc complete all as specified and directed. Note:- Two run of single core 6 Sqmm PVC cable with one run of earth conductor 6 Sqmm and steel conduit shall be measured as one unit.
M&L for sub main wiring using 4x10 Sqmm PVC insulated, unseathed stranded copper conductor cable of size 10 Sqmm of voltage rating upto and including 1100 volts drawn in and including concealed steel conduit of size not less than 32 mm dia with standard accessories alongwith two run of PVC ( green colour) insulated, unseathed, stranded copper conductor cable of size 2 x 10 Sqmm as earth continuity condultor all as specified and directed. Note:- Four run of single core 10 Sqmm PVC cable with Two run of earth conductor 10 Sqmm and steel conduit shall be measured as one unit.
M&L for Sub main wiring with FRLS PVC insulated unsheathed 2X 4 sqmm multistranded copper conductor cable 1100 V with 1X4 sqmm FRLS PVC insulated green multistranded copper cable for continuous earth drawn through & including PVC surface conduit on wall / ceiling of appropriate size not less than 20 mm dia & 1.8mm wall thickness with all accessories complete all as specified and directed. Note:- Two run of single core 4 Sqmm PVC cable with one run of earth conductor 4 Sqmm and PVC conduit shall be measured as one unit.
M&L for Earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron wire 4mm dia (without joint) as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 15mm bore medium grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed. Notes: 1. Rates quoted deemed to include cost of earth test point & earth wire & protection pipe upto 7.5 mtr beyond earth plate electrode. 2. Earth filling shall be done by vegetable soil. 3. Soil should be free from stone, boulders, aggregate, gravels etc.
M & L for earthing with Galvanised steel earth plate 600 mm x 600 mm x 6.00mm thick buried directly in ground vertically in pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 2.25 mtr below normal ground level connected to contineous (without joint) GI strip 32 mm x 6 mm as earthing lead by means of bolts, nuts, check nuts and washers of brass including gun metal or phosphorous bronze test point of size 75 x75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw all as specified including excavation and earth work and disposal of surplus soil including 40 mm bore GI tubing medium grade and necessary fitting for protection of GI strip including laying of charcoal, dust and common salt PCC (1:2:4) type B-I (using 20 mm graded crushed stone aggregate) earth pit with 40 mm x 40 mm x 6mm mild steel angle iron frame ,40 mm thick pre- cast RCC cover (1:2:4) type B-1 ( using 20 mm graded crushed stone aggregate ) reinforced with 8mm diaTMT bar @ 75mm c/c both way with mild steel handle 12 mm dia round bar ,15 mm thick plastering in cement mortar (1:4) internally and upto 150mm below ground level externally, funnel with wire mesh 20mm dia medium grade GI pipe for watering complete all as shown on electrical plate No.3 of SSR Part- 1( 2009 )and connected in earth test including testing completed all specified and directed. NOTE :- (i) The rates quoted shall also deemed to include the cost of Earth test point and earth strip and protection pipe upto 7.5 metre beyond the earth plates electrode and the earth resistance of the whole system shall be as near as possible to 0 but shall not in any case exced one ohm. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed / permitted.
Material and labour for earthing complete with Copper earth plate electrode 600 mm X 600 mm X 3.15 mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to copper strip 20 x 3 mm main earthing lead by means of copper bolts, nuts and washers all as shown in electrical plate no 3 of MES Schedule Part-I, earth lead protected by provision of GI medium grade pipe 25 mm bore connected to earth test point & to main switch board etc. with & including adequate quantity of charcoal dust and common salt alround earth plate, PCC 1:3:6 type C-1 using 20 mm graded stone aggregate for earth pit with pre cast RCC 1:2:4 type B-1 using 20 mm graded stone aggregate, 40 mm thick cover reinforced with 8 mm dia TMT bars 3 Nos both way with 12 mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh, etc. complete all as specified and directed. Note:- The cost of earth lead upto and including 7.5 metre only from the top of earth electrode are deemed to be included under this item and additional earth lead, if any required shall be measured and paid for seprately under appropriate item of Sch A.
Material and labour for earthing with copper plate as earth electrode 900 mm x 600 mm x 5 mm thick burried directly in the ground vertically in a earth pit not less than 2.25 metres in deep below normal ground level with top edge of plate not less than 1.5 metres below normal ground level connecting to the copper strip of size 50 x 6 mm upto 7.5 metre long from earth point to test point by means of bolts, nuts, check nuts and washers of copper and copper strip of size 32 x 6 mm protected by provision of GI mediumgrade pipe 50 mm bore including provision of concrete pit made with 40 mm thick cover of RCC 1:2:4 reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI medium grade 20 mm bore pipe for watering perforated at bottom, 1.75 metre long placed on top edge of earth plate, common salt & charcoal filling with fixing arrangement, funnel, wire mess, test point and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metres all as per electrical plate No. 3 of SSR2009 Part-I and connecting to lighting protection earth test points all as specified and directed including testing on completion. NOTE :- (i) The rates quoted shall also deemed to include the cost of Earth test point and earth strip and protection pipe upto 7.5 metre beyond the earth plates electrode and the earth resistance of the whole system shall be as near as possible to 0 but shall not in any case exced one ohm. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed / permitted.
Disconnecting & Taking down exhaust fan of any sweep and depositing to AGE E/M store yard including closing existing hole with brick masonry built in CM 1:6 duly pastered & finish distrubed surface to match the existing surface complete all as specified and directed.
S&F GI tubing light grade 50 mm bore including fittings for mechanical protection of earth continuity conductor complete all as specified and as directed.
S & F in position concealed PVC conduit pipe of 32 mm bore including fittings such as Tee, bends, elbow, reducer, junction box etc for telephone / LAN including taking out existing conduit by cutting groove in wall & refilling disturbed surface with CM 1:4 etc complete all as specified & directed.
S & F air termination copper rod 12 mm dia, 300 mm long, single pointed at top and properly threaded at bottom end including taking down of existing aluminium termination rod complete all as specified and directed.
Supply and fix earth continuity conductor or main earthing lead 20 x 3.15 mm copper strip laid in pipe/ fixed on wall or any other position for lightening protection including jointing by tinned copper/ brass nuts bolts and washers in addition to brazing at every joint complete including taking down of existing unserviceable aluminium strip all as specified and directed.
Supply and fix earth continuity conductor or main earthing lead 32 x 6 mm G.I.strip laid in pipe/ fixed on wall or any other position for lightening protection including jointing by tinned copper/ brass nuts bolts and washers in addition to brazing at every joint complete including taking down of existing unserviceable earth continuity wire all as specified and directed.
M & L for providing test point terminal block made out of gun metal or phosphorous bronze of size 75 mm x 75 mm x 25 mm drilled and screwed including 03 Nos. 8 mm dia 25 mm long hexagonal head screws complete all as specified and directed.
Material & labour for 40 mm bore GI tubing light grade in required length duly threaded on one side including fixing of socket complete as air termination stand/post fixed on roof top of building including taking down existing termination stand /post complete all as specified & directed.
Supply, install, commissioning and testing of Refrigerator of capacity 285-320 Ltrs, frost free, minimum BEE 3 star rated suitable for 230 Volt, 50 Hz AC complete all as directed.
Supply, install, commissioning and testing of split type wall mounted Air conditioner of capacity 1.5 TR (4500 K Cal/hr) single phase, (Non CFC/HCHC) suitable for 230 Volt + 10% , 50 Hz, AC supply complete with cordless remote control unit, minimum 5 star rating complete comprising of the following . (a) Indoor unit with three speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b) Out door unit comprising of compressor with motor, air cooled copper condenser with fan and motor. The unit shall be installed out side the building / on roof. (c) Refrigerant copper pipe for suction and discharge line with insulation, condensing water drain pipe protected by suitable size of flexible PVC conduit, control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable. (d) Making good disturbed surfaces to match the existing surface after plugging the hole etc. (e) PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in plinth suitable for installation of outdoor unit or powder coated MS bracket fixed on wall as per manufacture's instruction with necessary grouting of MS hold fast, bolts, washers duly painted and making good to disturbed surfaces suitable for installing outdoor unit of 1.5 TR AC complete all as specified and directed. (f) Electrical cable required to connect outdoor and indoor unit to voltage stablizer inclusive in above rate.
Supply, install, commissioning and testing of split type wall mounted Air conditioner of capacity 2.0 TR (6000 K Cal/hr) single phase, (Non CFC/HCHC) suitable for 230 Volt + 10%, 50 Hz, AC supply complete with cordless remote control unit, minimum 5 star rating complete comprising of the following :- (a) Indoor unit with three speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b) Outdoor unit comprising of compressor with motor, air cooled copper condenser with fan and motor. The unit shall be installed out side the building / on roof. (c) Refrigerant copper pipe for suction and discharge line with insulation, condensing water drain pipe protected by suitable size of flexible PVC conduit , control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable. (d) Making good disturbed surface to match the existing surface after plugging the hole etc. (e) PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in plinth suitable for installation of outdoor unit or powder coated MS bracket fixed on wall as per manufacture's instruction with necessary grouting of MS hold fast, bolts, washers duly painted and making good to disturbed surfaces suitable for installing outdoor unit of 2.0 TR AC complete all as specified and directed. (f) Electrical cable required to connect outdoor and indoor unit to voltage stablizer inclusive in above rate.
Supply and fixing voltage stabilizer for automatic opration, single phase naturally air cooled indoor type & designed for input variation 170V to 250V with out put voltage stabilized at 230 V with accuracy of ± 2.5 % suitable for refrigerator AC, 1.0 KVA capacity complete all as specified & directed.
Supply and fixing voltage stabilizer for automatic opration ,single phase naturally air cooled indoor type & designed for input variation 170V to 250V with out put voltage stabilized at 230 V with accuracy of ± 2.5 % suitable for 1.5 TR AC, 3.0 KVA capacity complete all as specified & directed.
Supply and fixing voltage stabilizer for automatic opration, single phase naturally air cooled indoor type & designed for input variation 170V to 250V with out put voltage stabilized at 230 V with accuracy of ± 2.5 % suitable for 2.0 TR AC, 4.0 KVA capacity complete all as specified & directed.
M/s Kohli Builders
RAVINDRA SALES
M/S LAKSHYA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .