Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC 498 GANNAUGHT ROAD MHOW MP PIN 453441 | MHOW | INDORE | MP | 453441 | L1 | Accepted-AOC Lowest of Quoted Rates | |
| 2 | L2₹6.2 L+₹54,770 (9.62%)Rejected-Finance | L2 | Rejected-Finance High Rates |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
29 Aug 2020, 6:00 pmClosed
GE (MCTE) MHOW
GE (MCTE) MHOW MP 453441
Repair to sunken floor arresting seepage in walls existing treatment and carrying out full treatment in REPAIR TO SUNKEN FLOOR ARRESTING SEEPAGE IN WALLS EXISTING TREATMENT AND CARRYING OUT FULL TREATMENT IN MD ACCN UNDER GE(MCTE) MHOW
2020_MES_351790_3
GE(MCTE)/MHOW/04T OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
GE (MCTE) MHOW
Repair to sunken floor arresting seepage in walls existing treatment and carrying out full treatment in REPAIR TO SUNKEN FLOOR ARRESTING SEEPAGE IN WALLS EXISTING TREATMENT AND CARRYING OUT FULL TREATMENT IN MD ACCN UNDER GE(MCTE) MHOW
8 documents required · 8 mandatory
₹500
Yes
GE (MCTE) MHOW
₹16,000
Yes
5 Sept 2020
8 Aug 2020
31 Aug 2020
8 Aug 2020
29 Aug 2020
15 Aug 2020
Amount
Demolition of Lime concrete /PCC of any description and in any position not otherwise specifically provided including removal of demolished material to a distance not exc. 100 m completed all as specified and directed.
M&L PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) mixed with integral water proofing Chemical PIDI PROOF-LW mixed in proportion 200ml /50 Kg cement of DR Fixit of pidilite industries Ltd or STP No.1 (liquid) of STP Ltd in proportion 200ml/50 Kg cement as in padding on roof surface finished fair and even without using extra cement all as specified and directed.
Supply only liquid water proofing compound all as specified and directed.
Taking down cement plaster on brick or stone walls etc including raking out joints hacking for key scrubbing down with water etc.
M & L for rendering 15mm thick in CM (1:4) on brick wall, concrete surface, fins, facia and chajja etc at any height, finished even smooth without using extra cement including mixing of liquid water proofing compound complete all as per specified and directed. Note : - Liquid WPC shall be measured & paid separately.
M & L, for preparation of new plastered surfaces and applying two coats of cement base paint over a coat of cement base primer on surfaces of walls complete all as specified & directed.
M&L, Preparation of surface naked brick/ concrete surface of wall by repairing with polymer modified mortar mixed with water proofing coating with two coat of Dr. Fixit Pidicrete URP @1.00 Kg with 1.50 Kg cement complete all as specified and as directed.
M&L for rendering 15mm thick in CM(1:4) on prepeared surface of wall under item above here in before and surface finished even and smooth w/o using extra cement complete all as specified.
M&L for applying two coats of oil bound distemper on prepared surface of wall in operation wise and after completion of first coat of emulsion paint it shall be got approved by Engg. in charge to satisfactory application and there after subsequent coat of paint shall be applied to entire satisfaction complete all as specified and as directed.
M & L for rendering 10 mm thick on ceiling surfaces in cement mortar 1:3 complete all as specified and as directed.
M&L for prepration of new plastered wall surfaces and applying three coats of white wash all as specified and as directed..
M&L, GI wire netting 0.90 mm dia and 12 mm mesh lathing to wall, ceilings, incl all laps, cutting and wastes complete all as specified and as directed.
M&L for 25mm thick PCC (1:2:4) type B0 (12.5mm aggregate) for floor finishes all as specified and as directed.
M&L for water proofing treatment to sunken floor in following sequence :-.
(a) Slope correction by using M-20 (Nominal Mix) concrete minimum 25mm thickness at one end and a slope of 1:20 by using 12.5mm graded stone aggregate mixed with liquid water proofing compound.
(b) PCC with cement concrete (1:1.5:3) type AO (using 12.5mm graded aggregate), 25 mm thick mixed with liquid water proofing compound as in sunken portion.
(c ) Vertical side plastered in CM (1:3), 15mm thick mixed with liquid WPC and 72 hrs testing for water tightness by ponding of water.
(d) Applications of two coats of blown type or industrial bitumen grade 85/25 at the rate of 1.5 Kg per sqm all over and testing again for water tightness by ponding of water for 72 hrs.
(e) Applying polythene film/membrane 50 micron thick laid over bitumenious primer @ 0.30 kg/sqm
(f) M&L for PCC (1:5:10) type E-2 using 40 mm graded stone aggregate filling as in mass concrete or all as directed at site .Note : - Liquid WPC shall be measured & paid separately.
Dismantling floor, hearth or wall tilling incl cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
M&L for non skid ceramic tiles of any size area not exc 0.16 Sqm and 7 to 8mm thick in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles over and inculding 15mm thick cement screed bed in CM (1:6) complete all as specified and directed.
M&L for glazed ceramic tiles of any size area not exc 0.16 Sqm and 7 to 8mm thick ,in vertical surfaces of wall such dado/skirting over and including 10mm thick cement plastering in CM (1:4) ,set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specially provided for beams,staircase,landing ,chajjas and similar suspended work.
M&L for reinforced cement concrete type B-1(1:2 :4) using 20 mm graded stone aggregate cast in situ as in chazza/facia and other similar articles with necessary form work all as specified and directed.
M&L for mild steel TMT reinforced bar 6 to 8 mm dia and over cut to length bent to shape required including cranking,bending spirally for hooping for column,hooking ends and binding with and including mild steel wire annealed not less than.9 mm dia or securing with clips etc.all as specified and directed.
M&L for form work to sides ,soffits of chajja,facia etc for fair fineshed of concrete surfaces complete all as specified and directed.
S & F in repair vitreous china squatting pan "orissa" pattern, size 580 x 440 mm white , with integral foot rests (excluding flushing cistern and flush pipe) incl connection to trap, and to flushing pipe, anti syphonage pipe, etc complete incl making good to floor all as specified and directed.
S & F in repairs vitreous china wash down water closet (pedestal pattern) pan white with “P” or “S” trap including connection to drain or outgoing and to syphonage pipe complete all as specified and directed.
S & F, in repair white plastic water closet seat, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminum hinging device as fixed in repair all as specified and directed. make- parryware/Hindware.
Taking up or down 15 mm bore steel tubing and connections, incl cleaning for refixing or removal to store all as specified and directed.
All as per item 25 above but 20 mm bore all as specified and directed.
Cutting chases, pining in brick work, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc, and cutting chases for concealed water tubing and makind good, cutting not exc 10 cm girth all as specified and directed.
S & F 15mm bore GI water tubing medium grade with all fittings fixed complete to walls or laid in floors, all as specified and directed.
All as per item 28 above but 20 mm dia all as specified and directed.
Dismantling of cast iron or reinforced concrete drain pipes 75/100 mm bore, jointed in cement mortar and taking out of trenches/wall, if required complete all as specified and directed.
S&F 110mm PVC SWR pipes single socketed in any length with rubber ring joints, laid in trenches or in floor complete all as specified and as directed.
Ditto all as per item above - but 75mm dia all as specified all as specified and directed..
S&F PVC (SWR) bends any radius 110mm dia. all as specified and directed.
Ditto all as per item above but 75 m dia all as specified and directed..
S&F in repairs 75 mm dia PVC floor trap with grating incl jointing with solvant cement all as specified all as specified and directed.
S & F in repairs cost iron soil waste pipes of size 75 mm dia centrifuging cast iron pipe in any length with or without ears jointed with cement and laid down in trenches.
All as per item No 37 above but 100 mm bore
S&F in repairs CI floor trap with grating incl joining to waste pipe fixed in cement concrete B1 (1:2:4) 75 mm dia. all as specified and directed.
S & F in repairs CI branch pieces single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches 75 mm dia all as specified and directed.
All as per item no. 39 above but 100 mm dia. all as specified and directed.
S&F, CI bends (any radius) diminishing pieces 75 mm dia. all as specified and directed.
All as per item 41 above but 100 mm dia. all as specified and directed.
S&F Stack clamps out of 50 mm by 5mm flat iron and 16 mm dia round iron stays, incl bolts and nuts and securing ends of stays to wall or roof for 75/110 mm bore pipe complete all as specified and directed.
S & F in repairs of PVC low level flushing cistern white of 10 ltr capacity with inlet, ball valve, ball valve, float and handle including brackets all as specified and directed.
S & F, in repairs of vitreous china wash hand basin coloured flat back type size 580 x 450 mm with brackets fixed to wall complete with 32 mm dia CP waste coupling and connecting to trap all as specified and directed.
S & F in repairs of CP soap dish fancy type brass and fixed with CP brass screws and plastic cleat all as specified and directed.
S & F in repairs 15 mm bore Fancy type, long shank Chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
S & F in repairs 15 mm bore Fancy type pillar taps, long shank, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed.
S&F in repairs PVC connections 15 mm dia 450 mm long with brass nuts at both ends as in repairall as specified and directed.
S & F in repairs Jet spray, brass chromium plated, with 1 mtr PVC pipe make - Plumber/Marc/Jaquar.
S & F in repairs chromium plated fancy type two way bib cock of 15mm dia complete all as specified and directed.
S & F in repairs CP brass center hole mixer for wash basin for mixing hot and cold water screwed down for iron pipe and fixed for 15 mm bore pipe size of make MARC (Catalogue No MOR 1100)/Plumber Cat No. LL-55102/Jaquar Cat No. 167. all as specified and directed.
S & F in repairs brass chromium plated fancy type angle valve/stop valves for 15 mm bore size complete all as specified and directed.
S & F in repairs brass CP wall mixer for mixing hot & cold water with provision for over head shower with arm and long bend pipe and wall flanged screwed down for iron pipe of 15 mm bore size complete all as specified and directed.
S & F in repairs CP grating of dia 100 mm complete all as specified and directed.
M&L cement concrete type C1, (1:3:6) 20mm graded stone agreated as in bed block, coping all as specified and directed.
SAHYOG ELECTRIC
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .