| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.6 LAccepted-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹35.2 L+₹4.5 L (14.8%)Rejected-Finance 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Being not L1 | |
| 3 | Rejected-Technical NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | - | Rejected-Technical Being not eligible due to not enlisted in requisite category |
Tender Value
₹39.8 L
EMD Value
₹79,600
Closing Date
18 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Neeraj Mehrotra, IDSE, CWE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
MAINTENANCE AND REPAIR TO HT SYSTEM CONNECTED ITEMS AT AFS YELAHANKA
2024_MES_667602_1
86171/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) Yelahanka
As per tender documents
7 documents required · 7 mandatory
₹500
GE (AF) YELAHANKA
₹79,600
23 Oct 2024
24 Jul 2024
25 Sept 2024
24 Jul 2024
18 Sept 2024
9 Aug 2024
24 Jul 2024 - 31 Jul 2024
Amount
Excavation in trenches not exceeding 1.5 m deep and not exceeding 1.5 m wide and getting out in hard/dense soil, complete all as specified and directed.
Returning and filling of trenches in two parts (i) using riddled soil obtained from excavated soil upto depth of 30cm (8cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified and directed. Note : - Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS 1255-1983 and refilling in trenches as in cable cushioning.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed.
M&L for stone aggregate of size not exceeding 40 mm deposited spread and leveled in layers not exceeding 15 cm to a true surface of broken stones for transformer yard and pole structure area.
M & L for PCC 1:3:6 type C1, 20mm graded aggregate for coping of poles etc all as specified and as directed.
Supply, Lay, testing and commissioning of HT UG cable XLPE insulated , screened, PVC bedded, galvanized steel strip or wire armored electric power cable (heavy duty earthed) with stranded aluminium conductor, 11000 volts grade of size 3 core 95 Sqmm complete laid in trenches or fixed on walls /floors etc.all as specified and as directed.
Supply, Lay, testing and commissioning of HT UG cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armored electric power cable (heavy duty earthed) with stranded aluminium conductor,11000 volts grade of size 3 core 120 Sqmm complete laid in trenches or fixed on walls /floors etc.all as specified and as directed.
Supply, Lay, testing and commissioning of HT UG cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armored electric power cable (heavy duty earthed) with stranded aluminium conductor,11000 volts grade of size 3 core 240 Sqmm complete laid in trenches or fixed on walls /floors etc.all as specified and as directed.
M & L for Boring of holes under roof, pavement, hardstanding by trenchless technology using ultrasound technique with suitable machine including HDPE pipe of 75mm dia suitable for 0.4mpa working pressure all as pecified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1, flat of size 300mm x 180mm x 40mm complete all as specified and directed.
M & L for fault finding of HT 11 KV 3 core, XLPE cable of size 95/120/185 sqmm by thumping and echo instrument/ computer aided fault finding kit, and finding out exact location of the fault complete all as specified and directed. Note : Necessary excavavation, reterning refilling and removal of soil shall be measured and paid separately.
Supplying and jointing in repair straight through jointing kit (Heat shrinkable) with all accessories suitable for HT 11 KV XLPE earthed UG cable of size 3 core 50 to 95 Sqmm aluminum conductor and testing complete all as directed. (Make: Birla 3M/Denson/M Seal/Raychem)
Supplying and jointing in repair straight through jointing kit (Heat shrinkable) with all accessories suitable for HT 11 KV earthed XLPE earthed UG cable of size 3 core 120 to 185 Sqmm aluminum conductor and testing complete all as directed. (Make: Birla 3M/Denson/M Seal/Raychem)
Supplying and jointing in repair straight through jointing kit (Heat shrinkable) with all accessories suitable for HT 11 KV earthed XLPE earthed UG cable of size 3 core 240 to 400 Sqmm aluminum conductor and testing complete all as directed. (Make: Birla 3M/Denson/M Seal/Raychem)
Supply and fix in repair Indoor type cable terminations (heat shrinkable) with all accessories suitable for 3 core 11KV HT U/G XLPE earthed cable of size 50 to 95 sqmm Sq.mm including testing complete all as specified and as directed. Make - M-Seal/Denson/Raychem or equivalent.)
Supply and fix in repair Indoor type cable end terminations (heat shrinkable) with all accessories suitable for 3 core 11KV U/G XLPE earthed cable of size 120 to 185 sqmm Sq.mm including testing complete all as specified and as directed. (Make: M-Seal/Denson/Raychem) or equivalent.
Supply and fix in repair outdoor type cable terminations (heat shrinkable) with all accessories suitable for 3 core 11KV U/G XLPE earthed cable of size 50 to 95 Sq.mm including testing complete all as specified and as directed. Make - M-Seal/ Denson/Raychem/Birla 3M or equivalent.
Supply and fix in repair outdoor type cable end terminations (heat shrinkable) suitable for 3 core 11KV U/G XLPE earthed cable of size 120 to 185 Sq.mm including testing complete all as specified and as directed. (Make:M-Seal/Denson/Raychem/Birla 3M) or equivalent.
M & L for Preparing to old painted steel/metal surface of any description over 10 CM in width or girth of HT VCB panel indoor/Outdoor of various locations and applying two coats of synthetic enamel paint with fine quality with suitable spray gun including writing of panel details all as specified and as direted. Note:- Writing includes SL No, details of Incoming and outgoing, area indication as directed.
Dismantling of ACSR conductor of any size/type all as specified and as directed.
M & L for ACSR aluminium conductor, steel reinforced of suitable size all as directed.
Dismantling cross arms of MS channel or angle etc complete and setting aside for re-use within 50m or for offering credit all as directed.
M & L for cross arms bracing supports clamps and back plates fabricated from sturctural steel sections including nuts,bolts, washers, weldding, bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of Synthetic enamel paint.
Dismantling insulators of any type and any size all as directed.
M/L for pin type porcelain vitreous white, brown or green insulators including one galvanised mild steel spindle two galvanised iron washers one GI nut 150mm height 150mm dia for 11 KV complete all as specified and directed.
M/L disc insulator porcelain vitreous 145 mm high and 255mm dia ball and sockent type, white brorwn or green single disc assembly complete all as specified and directed.
Supply and fix lightning arresters high tension expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11000 volts including taking down old unserviceable lightning arresters.
Taking down GOD alongwith dropout fuse assembly of any capacity all as directed.
M & L for gang operated device (GOD) HT 11 KV outdoor type suitable for vertical mounting fixed type complete with insulators and frame with operating mechanism (including GI pipe medium grade 25mm dia pipe, necessary supports) worked from ground level complete with locking arrangements including pad locks with key of rating 400 Amps all as specified and directed. (Make Jayashree/Jayapuria/BHEL/GODREJ)
Repairs to air break gang operated switches / vertical / horizontal mounted including operating mechanism for replacement of broken / worn out components for moving contacts blades, fixed contact jaw, copper braded tape, MS supports, back connected plates, jumper carriers. Note : (i) Spare / components shall be measured and paid separately as Supply only. (ii) Fixing charges for labour shall deemed to be included in unit rate quoted.
Supply only Moving contacts blades
Supply only Fixed contact jaw
Supply only copper braded tape
Supply only MS supports
Supply only back connected plates
Supply only jumper carriers
M&L for expulsion fuse unit assembly, out door type, single pole 50 Amps capacity including fuse element 25 Amps to 50 Amps and insulator conforming to IS specifications suitable for HT 11KV all as specified and directed.
M&L for jumper connections between GOD and drop out fuses and transformers with ACSR conductor 6/1X3.35 mm (rabbit) not exe. 2 mtr long including necessary lugs where ever required /aluminum heavy duty PG clamps / binding properly without any loose contact all as directed after removing the old jumpers including PVC sleeve not more than 1.70 Rm, all as specified and as directed.
M&L for jumper connections between GOD and drop out fuses and transformers with ACSR conductor 6/1X3.35 mm (rabbit) exceeding. 2 mtr long but not exceeding 3.50 mtr longincluding necessary lugs where ever required /aluminum heavy duty PG clamps / binding properly without any loose contact all as directed after removing the old jumpers including PVC sleeve not more than 3.20 Rm, all as specified and as directed.
Material and labour for repair and servicing of HT 11KV four pole structure by repalcing galvanized PG clamps, GI bolts and nuts,pieces of ACSR conductor with insulation of any size as jumpers including lubricating the moving parts of AB switch and cleaning of all disc/pin insulators and applying silicon compound for prevention of arcing due to dust/salt deposits over the surfaces including applying one coat of red oxide primer on rusted portions after preparation of surfaces & applying a coat of aluminium paint to the entire steel structure complete all as specified and directed.
Material and labour for repair and servicing of HT 11KV two pole structure by repalcing galvanized PG clamps, GI bolts and nuts, pieces of ACSR conductor with insulation of any size as jumpers including lubricating the moving pars of AB switch and cleaning of all disc/pin insulators and applying silicon compound for prevention of arcing due to dust/salt deposits over the surfaces including applying one coat of red oxide primer on rusted portions after preparation of surfaces & applying a coat of aluminium paint to the entire steel structure complete all as specified and directed.
M & L for Preparing old faded painted surfaces of 11m long steel tubular pole complete including all accessories such as cross arms bracings, brackets etc and paints with two coats of Aluminium paint of approved tint including writing pole number with paint same as existing earlier all as directed.
M & L for Preparing of old faded paint surface and painting with paint to existing HT PCC/RCC poles of size 11m long upto the height of 1.2 Mtr from the bottom with approved white and Blue colour alternatively including numbering of poles same as existing earlier all as specified and directed.
Online Centrifuging (filteration/dehydration) of transformer oil including checking initial and after filteration Dielectric Strength of oil for transformers, Isolation transformers and voltage stabilizers located in various places of technical and domestic area with suitable machine having filteration, heating and pumping facility to improve the dielectric strength/insulation value of oil. Note :- (i) Dielectric strength of oil after filteration/dehydration shall not be less than 60 KV at 2.5 mm gap. (ii) Oil for toping up shall be measured and paid separately under relevant item of this schedule (iii) The contractor will take shut down orders in writing atleast two daysin advance from Engr-in-charge before commencement of work. (iv) The dielectric strength of oil shall be tested before and after filtration and necessary test certificates shall be submitted to the Engr-in-chaerge.
Supply & topping up of new transformer oil conforming to IS-335/1983 for transformer/VL unit/Isolation transformer/Servo Voltage Stabilizer, up to the marked level all as specified & as directed. Note: (i) Mineral oil grade shall be used. (ii) The transformer oil should have a IR value of the oil should not less than 60KV/Min (iii) The quoted rate shall be deemed to cost of filtration and testing etc.
Supply and fix the silica Gel container (breather) including silica Gel suitable for the transformers of capacity 50 KVA to 200 KVA after dismantling the old unserviceable breather complete all as specified and directed.
Supply and fix the silica Gel container (breather) including silica Gel suitable for the transformers of capacity 250 KVA to 500 KVA after dismantling the old unserviceable breather complete all as specified and directed.
Supply and fill silica Gel for 11KV/415V Transformers rated of various capacities by replacing the contaminated one from the transformer, complete all as specified and directed.
Material and labour for repairs to transformer at various locations of technical and domestic area after removing nuts and bolts of transformers of capacity 200 to 500 KVA and taking out the leaked portion such as bushes, joints, and replace the gaskets after cleaning the surface and refixing the nuts and bolts and ensure no leakagre complete all as specified and directed.
Opening carefully and replace the clear acrylic sight window cover along with gasket of oil level indicator of the transformer of capacity 100 KVA to 400 KVA all as specified and as directed.
M&L for painting distribution transformers/Isolation Transformers of capacity 50/62.5/100/125 KVA with two coats of synthetic enamel paint after neatly cleaning and preparing the surface all as directed for the transformers of the following capacity including writing SM/MES No. with white colour synthetic enamel paint all as specified and directed.
M&L for painting distribution transformers/Isolation Transformers of capacity 160 KVA KVA with two coats of synthetic enamel paint after neatly cleaning and preparing the surface all as directed for the transformers of the following capacity including writing SM/MES No. with white colour synthetic enamel paint all as specified and directed.
M&L for painting distribution transformers/Isolation Transformers of capacity 200 KVA KVA with two coats of synthetic enamel paint after neatly cleaning and preparing the surface all as directed for the transformers of the following capacity including writing SM/MES No. with white colour synthetic enamel paint all as specified and directed.
M&L for painting distribution transformers/Isolation Transformers of capacity 250 KVA KVA with two coats of synthetic enamel paint after neatly cleaning and preparing the surface all as directed for the transformers of the following capacity including writing SM/MES No. with white colour synthetic enamel paint all as specified and directed.
M&L for painting distribution transformers/Isolation Transformers of capacity 300/315 KVA KVA with two coats of synthetic enamel paint after neatly cleaning and preparing the surface all as directed for the transformers of the following capacity including writing SM/MES No. with white colour synthetic enamel paint all as specified and directed.
M&L for painting distribution transformers/Isolation Transformers of capacity 500 KVA KVA with two coats of synthetic enamel paint after neatly cleaning and preparing the surface all as directed for the transformers of the following capacity including writing SM/MES No. with white colour synthetic enamel paint all as specified and directed.
Checking & testing of out door transformers of any type / capacity for IR value by applying 5000 V / 500 V by means of HT / LT meggar after removing primary / secondary terminal connections including reconnecting and charging back the transformer all as specified and directed by Engr-in-charge. Note : Test results obtained shall be recorded and produced to Engr in Charge in proper format duly signed by the contractor.
Supply & fix porcelain vitreous HT 11 KV bushings with copper/brass studs suitable for out door distribution transformers of capacity upto 400 KVA after removing the old unserviceable studs / bushings and draining out the transformer oil from the top level up to conservator of the transformer and removing the top cover of the carefully and refixing and refilling the oil all as directed.
Supply & fix porcelain vitreous LT 11 KV bushings with copper/brass studs suitable for out door distribution transformers of capacity upto 400 KVA after removing the old unserviceable studs / bushings and draining out the transformer oil from the top level up to conservator of the transformer and removing the top cover of the carefully and refixing and refilling the oil all as directed.
Supply and fix Tap changeover mechanism for 400/500 KVA step down transformer as per existing make.
Supply and fix Tap changeover mechanism for 125 to 300 KVA step down transformer as per existing make.
Supply and fix Tap changeover mechanism for 50/100 KVA step down transformer as per existing make.
Repairs/Servicing of VL switch 11KV including cleaning of complete system taking down old ruptured fuse units replace with new fuse and filteration of existing oil and making good of the fixed and moving contacts, connecting the switch for operation and testing including painting with two coats of synthetic enemel paint complete all as specified and directed.
Surface dressing in hard / dense soil not exceeding 15 cm deep and clearing all the grass weeds etc in the sub station yards after removing stone aggregate aside all as directed at site including setting / spreading back the aggregate including filling of river sand/ stone dust upto 15cm complete all as specified and directed. Note:- (i) Stone dust/river sand shall be measured and paid separately under relevant items of this schedule. (ii) The rate also deemed to be included for labour. (iii) All the sub station yards shall be kept clean through out the contract period by removing the grass/weeds as many as times required depending on the growth of the grass.
M&L for Servicing to vaccum circuit breakers (Make: KIrloskar/ABB) of rating 630/800 Amps, 11 KV, 3 Phase of different Make by removing incoming and outgoing cable connections, moving and fixed contacts cleaning the parts with CTC, servicing contacts, checking the VCB panel healthiness of faults tripping system by using secondary injection method and checking breaker, closing coils, improving the insulation resistance and re-assembling the same with new or old spares and checking the proper functioning of the whole VCB all as specified and as directed. Note :- (i) New spare shall be measured and paid separtely. (ii) Hiring of technician/service engineer from Kirloskar/ABB is the responsibility of contractor and rate for the same deemed to be included in the quoted rate.
Disconnect and taking out the Numeric/ Microprocessor based relay including earth fault and over current relays of any type of any Make from 11 KV HT panel, cleaning the contacts, calibrating the relay by conducting secondary injection tests, checking of current transformer, rectification of defects in control wiring for proper tripping of circuit breakers through CTs and relay and tripping coils, adjustment/setting to plug and time multiplier settings of the relay to achieve the discrimination in tripping, tune/synchronies upstream breaker relay settings, re-installation of relay, testing & commissioning etc complete all as specified and as directed. Note: The Contractor has to arrange necessary testing Kits, testing equipments, tools etc and shall also submit detailed test reports, panel wise, duly spiral bound. Rental rates for the testing/calibration kits & connected equipments are deemed to be included in the quoted rate. Testing & tuning shall be carried out in the presence of Engr in Charge.
Supply and fix Earth fault relay (Electro Mechanical).
Supply and fix Over Current Relay (Electro Mechanical).
Supply only micro processor based numerical relay with programmable alarm Annunciator Relay.
Supply only LED Indication Lamps 24 V DC/AC Neon type (R/Y/B).
Supply and fix closing coil box assembly with coil suitable for existing VCB of make (Kirloskar/ABB) 30 V DC for HT 11 KV VCB 630 Amps all as specified & directed.
Supply and fix Auxilary switch 4NO+4NC suitable for existing HT, 11KV, VCB 630 Amps/800Amps of make ;Crompton/ ABB all as directed.
Supply and fix TNC switch suitable for existing 11KV VCB 630 Amps/800Amps all as directed.
Supply and fix tripping coil box assembly with coil 30V DC for HT 11KV VCB 630 Amps/800Amps of make Crompton/ ABB all as specified and as directed.
Supply and fix free trip mechanism suitable for existing 11KV VCB 630 Amps/800Amps of make Kirloskar/ABB all as directed.
M&L for replacing the unserviceable batteries for HT VCB relay circuit with maintenance free sealed battery of size 2V/100AH all as directed. Make AMCO/ EXIDE.
Supply and fix surge arrestor(set of 3) suitable for existing 11KV HT VCB/ VCBs/RMUs panels of capacity 800A/630A for protection of installations from external surge including testing all as specified and directed.
Supply and replacement of PT 3 phase 3 limb single ratio 11KV/110V, 150VA per phase & accuracy Class-1 all as specified and directed.
M&L for fixing earth pit indicators made out of 3 mm thick MS sheet of size 200mmx150mm duly fixed in MS angle iron 25mmx25mm of 450 mm long to be fixed to ground by means of cement concrete including painting with two coats of synthetic enamel paint over a coat of red oxide primer and writing the earth resistance complete including excavation and earth work PCC type C1, 1:3:6 of size 150x150x150mm all as directed, including dismantling and taking out the old rusted / out lived earth indicators all as specified and as directed.
M&L for Earthing complete with galvanised steel earth plate electrode 600mmx600mmx6mm size burried directly in ground vertically to a depth not less than 2.25 mm below ground level with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanised earth strip 32x6 mm size protected by 40 mm light grade pipe upto 7.5 m length by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-1 including necessary excavation earth work, drilling of holes for electrode, PCC 1:3:6 type C1, RCC cover slab, 50 mm thick with 1:2:4 type B1, using 8 mm CTD bars 140 mm C/C both- way with suitable handle, watering pipe 20 mm dia light grade GI, funnel, charcoal, salt all as specified and as directed by Engineer in charge including taking down old unserviceable earthing assembly all as specified and directed.
M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthling etc. as required 32X6mm GI Strip all as specified and directed.
M & L for servicing of servo controlled volatge stabilizer of capacity 100 KVA of make : Powerone, situated at AF NET SITE-I & SITE-II by disconnecting the LT cables and draining out oil complete and taking out the core and checking the continuity and insulation values of all three phases, reinsulating if required and inspecting and replacing the PCB in case of repair, repair and servicing of breaker, removing and cleaning the sludge from the tank, refilling the oil after filtering by using online centrifuge machine and obtain the dielectric strength of oil not below 100 KV at 2.5 mm gap including testing of volatge stabilizer by reconnecting the disconnected cables and calibrating complete all as specified and as direcrted. Note : (a) The rate shall also deemed to be included the rate for (i) Technician, Electrician,and labours (ii) Supply and fixing of drain valve to the voltage stabilizer suitable for of make : Power one. (b) Filtration of oil by using online centrifuge machine and top up of oil will be measured and paid separately under relevant items of the schedule.
M & L for servicing of Isolation transforners of capacity 50 KVA of Make : Power one situated at Dornier/AN-32 FTD by disconnecting the HT/LT cables and draining out oil complete and taking out the core and checking the continuity and insulation value of coils for all three phases, inspecting and reinsulating coils if required, repair and servicing of breaker, replacing the wornout parts if any, removing and cleaning the tank, refilling the oil after filtering by using online centrifuge machine and obtain the dielectric strength of oil not below 60KV incliuding testing of isolation transformer by reconnecting the disconnected cables and calibrating complete all as specified and as direcrted. Note : (a) The rate shall also deemed to be included the rate for (i) Technician, Electrician,and labours (ii) supply and fixing of drain valve to the isolation transformer of make : Power one. (b) Filtration of oil by using online centrifuge machine and top up of oil will be measured and paid separately under relevant items of the schedule.
M & L for servicing of volatge stabilizer of capacity 630 KVA situated at MAFI Sub stn-I by disconnecting the HT/LT cables and draining out oil complete and taking out the core and checking the continuity of all three phases, inspecting and replacing the PCB in case of repair,repair and servicing of breaker (MAke : L& T), refilling the oil after filtering by using online centrifuge machine and obtain the dielectric sterngth of oil not below 50KV incliuding testing of volatge stabilizer by reconnecting the disconnected cables complete all as specified and as direcrted. Note: (a) The rate shall also deemed to be included the rate for (i) Technician, Electrician,and labours (ii) supply and fixing of drain valve to the voltage stabilizer suitable for of make:Volina (b) Filtration of oil by using online centrifuge machine and top up of oil will be measured and paid separately under relevant items of the schedule.
M & L for servicing of Isolation transforners of capacity 630 KVA situated at MAFI Sub stn-I by disconnecting the HT/LT cables and draining out oil complete and taking out the core and checking the continuity of all three phases, inspecting and replacing the PCB in case of repair,repair and servicing of breaker( MAke : L & T) ,replacing the wornout parts if any, refilling the oil after filtering by using online centrifuge machine and obtain the dielectric sterngth of oil not below 50KV incliuding testing of volatge stabilizer by reconnecting the disconnected cables complete all as specified and as direcrted. Note : (a) The rate shall also deemed to be included the rate for (i) Technician, Electrician,and labours (ii) supply and fixing of drain valve to the voltage stabilizer of make:Volina (b) Filtration of oil by using online centrifuge machine and top up of oil will be measured and paid separately under relevant items of the schedule.
M & L for servicing of volatge stabilizer of capacity 200 KVA situated at MAFI Sub stn-II by disconnecting the HT/LT cables and draining out oil complete and taking out the core and checking the continuity of all three phases,replacing the wornout parts if any, inspecting and replacing the PCB in case of repair,repair and servicing of breaker (MAke : L& T), refilling the oil after filtering by using online centrifuge machine and obtain the dielectric sterngth of oil not below 50KV incliuding testing of volatge stabilizer by reconnecting the disconnected cables complete including testing all as specified and as direcrted. Note: (a) The rate shall also deemed to be included the rate for (i) Technician, Electrician,and labours (ii) supply and fixing of drain valve to the voltage stabilizer of make:Volina (b) Filtration of oil by using online centrifuge machine and top up of oil will be measured and paid separately under relevant items of the schedule.
M & L for servicing of Isolation transforners of capacity 200 KVA situated at MAFI Sub stn-II by disconnecting the HT/LT cables and draining out oil complete and taking out the core and checking the continuity of all three phases, inspecting and replacing the PCB in case of repair,repair and servicing of breaker( Make : L & T) , replacing the worn out parts if any, refilling the oil after filtering by using online centrifuge machine and obtain the dielectric sterngth of oil not below 50KV incliuding testing of volatge stabilizer by reconnecting the disconnected cables complete including teating all as specified and as direcrted. Note: (a) The rate shall also deemed to be included the rate of (i) Technician, Electrician,and labours (ii) supply and fixing of drain valve to the voltage stabilizer of make:Volina (b) Filtration of oil by using online centrifuge machine and top up of oil will be measured and paid separately under relevant items of the schedule.
M & L for servicing of Isolation transforner dry type of capacity 62.5 KVA (MAke:Power One) situated at ATC by disconnecting the HT/LT cables and taking out the core from the isolation transformers with the help of crane and checking the continuity of each phase including making varnishing, lubricate moving parts, servicing all other spare parts by using CTC and testing complete after reconnecting the disconnected cables complete all as specified and as direcrted. Note: The rate shall also deemed to be included the rate of (i) Technician, Electrician,and labours (ii) crane and operator
M&L for Servicing to Ring main unit (Make: Seimens) of rating 630/800 Amps, 11 KV, 3 Phase by removing incoming and outgoing cable connections, the control circuit wiring, checking of oprerating, spring charging and interlocking mechanism and ascertaining the RMU healthiness of faults tripping system by using secondary injection method and checking breaker, closing coils, improving the insulation resistance and connecting all cable connections and checking the proper functioning of the whole RMU including replacement of minor items all as specified and as directed. Note :- (i) Hiring of technician/service engineer from Seimens is the responsibility of contractor and rate for the same deemed to be included in the quoted rate.
Supply and fix cable route indicator made out of 3 mm thick MS sheet of suitable size (As approved by Engr-in-charge) duly painted with two coats black paint over a coat of red oxide primer and writing cable direction, Nature of cable (i.e MAFI, MRS, Sub station etc.), size of cable (in SQMM), type of cable (HT/LT cable) with white paint, mounted on angle iron 40x40x3 mm, angle height 45 cm, (30cm below ground level) with PCC 20cmx20cmx15cm all as specified and as directed.
navreet construction (BID ID -3090526)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .