| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.1 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest quoting | |
| 2 | L2₹14.6 L+₹1.9 L (15.3%)Rejected-AOC | L2 | Rejected-AOC Rejected being higher quoting | |
| 3 | L3₹15.6 L+₹3.0 L (23.7%)Rejected-AOC | L3 | Rejected-AOC Rejected being higher quoting | |
| 4 | L4₹19.1 L+₹6.5 L (51.4%)Rejected-AOC | L4 | Rejected-AOC Rejected being higher quoting | |
| 5 | L5₹19.2 L+₹6.5 L (51.7%)Rejected-AOC | L5 | Rejected-AOC Rejected being higher quoting |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
14 May 2020, 6:00 pmClosed
GE Hisar
Garrison Engineer Hisar Military Station Hisar - 125006
GE(H)-01/2020-21
2020_MES_338663_1
GE(H)-01/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
Hisar Mil Stn
As per Tender documents
6 documents required · 6 mandatory
₹500
GE Hisar
₹52,000
Yes
30 May 2020
13 Apr 2020
16 May 2020
13 Apr 2020
14 May 2020
1 May 2020
Amount
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth for laying cables, foundation for pole etc and getting out in soft/loose soil complete all as specified and as directed.
Excavating in trenches not exc 1.5 metre wide and exc 1.5 metre and not exc 3.0 metre in depth for foundation or for shafts, walls, manholes, laying of cables, pipes etc not exc 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth for laying cables, foundation for pole etc and getting out in hard/dense soil etc complete all as specified and as directed.
Returning filling in incl spreading leveling watering and well ramming in layers n. exc 25cm thick etc complete all as specified and as directed.
Removing excavated material to distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point etc complete all as specified and as directed.
M&L for Sand cushioning 230mm thickness with dry sand (one layer of 80mm thickness before laying of cable and other layer of 150mm thickness after laying of cable) and punned down to 180mm after laying of cable in trenches for protection of cable complete all as directed. Note :- For the purpose of payment only punned thickness shall be measured.
M&L for brick covering to underground electric cable using sub class ‘B’ bricks, laid dry, flat, perpendicular to the direction of cable etc complete all as specified and directed.
Dismantling the existing street light fittings of any type from 9/11 mtr poles or from high mast light including unsv wires, junction boxes and all worn out accessories complete all as specified and directed.
Material & labour cement concrete (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in foundation complete all as specified and directed.
Material & labour PCC (1:3:6) type C-1 (using 20 mm graded mechanically crushed stone aggregate) as in mass concrete including necessary form work complete all as specified and directed.
M&L for PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in coping and the like including weathering slightly rounded or chamfered angles complete all as specified and directed.
Supply, erecting & fixing in true vertical position pre stressed concrete pole conforming to IS-1678 of 9 mtr long, 102 mm x 172 mm at top and 102 mm x 279 mm at bottom class 10 complete all as specified and directed. Note :- Earth work & PCC shall be measured and paid separately.
Supply , laying , jointing, testing and commissioning of 10 sqmm 2 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors confirming to IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete all as specified. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
Supply , laying , jointing, testing and commissioning of 16 sqmm 4 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors confirming to IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete including taking out existing unserviceable cable all as specified. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
Supply , laying , jointing, testing and commissioning of 16 sqmm 4 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors confirming to IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete all as specified. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
Supply , laying , jointing, testing and commissioning of 70 sqmm 3.5 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors confirming to IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete all as specified. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
M&L for Galvanized iron tubing, 50mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (40mmx6mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note :- Excavation & earthwork shall be measured & paid for separately.
M&L in replacement for Galvanized iron tubing, 50mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (40mmx6mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note :- Excavation & earthwork shall be measured & paid for separately.
M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC rigid non metallic conduit 20mm dia medium grade (ISI marked) with all fittings such as tees, bends etc fixed on wall/ celing including sunk type pressed steel box covered with and including 3 mm thick new bakelite laminated sheet top cover ‘Hylam’, complete, all as specified & directed. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).'
M&L for point wiring for one power point controlled by one, one way switch with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including concealed PVC rigid non metallic conduit 20mm dia medium grade (ISI marked) with all fittings such as tees, bends etc including sunk type pressed steel box covered with and including 3 mm thick new bakelite laminated sheet top cover ‘Hylam’, complete, all as specified & directed. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).'
S&F switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts all as specified & directed.
S&F ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed.
M&L for sub main wiring with two runs of 6.00 sqmm (nominal area) size main cable & one run of 6.00 sqmm size earth continuity conductor in green colour, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked (IS: 694) cables, drawn through & including PVC conduit fixed on wall/ceiling with PVC saddles as per IS, ISI marked & conduit fittings/accessories of medium grade not less than 25mm dia complete including dismantling & taking down old unserviceable sub main wiring. Note :- 02 runs of 6.00 sqmm size, 01 run of 6.00 sqmm size cable & conduit with accessories shall be measured as one run length for payment purpose.
S&F street light LED light fitting 60 Watt, new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device , connected with and including 0.5 sqmm flexible copper multistranded conductor cable including fixed on wall / pole all as specified and directed. Make : Cat Part No ENDURAPEARLNEOSL60WLED757PASYTOPC of Havells or LSTP-60-CDL-M of Crompton or LTESSI60WLED of C&S equivalent of make as mentioned in Appx 'C' list of makes here-in-after.
S&F LED street light luminaries of capacity 100 Watt, aluminium pressure die cast housing with epoxy powder coating, toughened glass cover having IP66 protection, prismatic polycarbonate cover with individual LED lense fixed on pole / wall all as specified and directed. Make : Cat Part No ENDURAPEARLMAGNUMSL100WLED757PASYTOTGAST of Havells or Cat No LTESSS100WHPLED/LS of C&S or Cat part No LSTP-100-CDL-M of Crompton or equivalent of make as mentioned in Appx 'C' list of makes here-in-after.
S&F LED street light luminaries of capacity 120 Watt, aluminium pressure die cast housing with epoxy powder coating, toughened glass cover having IP66 protection, prismatic polycarbonate cover with individual LED lense fixed on pole / wall all as specified and directed. Make : Cat Part No ENDURAPEARLMAGNUMSL120WLED757PASYTOTGASTHO of Havells or Cat No PCGLS C2 120 of Polycab or Cat No LTESS120WHPLED/LS of C&S or Cat Part No LSTP-120-CDL-M of Crompton or equivalent of make as mentioned in Appx 'C' list of makes here-in-after.
S&F LED flood light fitting of cap 100 Watt or nearest above, energy saving, environmental friendly, long life, exclusive innovative, die cast aluminium IP65 flood light suitable for high mast complete with accessories, pre-wired upto a terminal block and mounting attachment complete all as specified and directed. Make: Cat Part No JETAIRISFLS100WLED757SYMLTG of of Havells or Cat Part No LTESSS100WHPLED of C&S or Cat part No PCGLF T1 02 100 57 of Polycab or equivalent of make as mentioned in Appx 'C' list of makes here-in-after.
S&F LED flood light luminaries of capacity 240 Watt or nearest above, energy saving, environmental friendly, long life, exclusive innovative die cast aluminium IP65 protection with high power LEDs as light source, suitable for high mast inclusive of all accessories for fixing on mounting all as specified and directed. Make : Cat Part No JETAVALOURF240WLED757MODWPLTD of Havells or Cat Part No LTEF240WHPLED of C&S or equivalent of make as mentioned in Appx 'C' list of makes here-in-after.
Rewinding of motor for high mast light of cap 2 HP including repair to winch to lift and lower the high mast light including arrangement for repair / replacement of pinion / gear box, chain, wire etc complete for making the motor and the movement of light carriage simultaneously all as specified & directed.
S&F in replacement street light junction box of size not less than 300mmx200mmx150mm, LT (415 Volts, 3 Phase, 4 wire supply), factory assembled, outdoor type, 2mm thick MS sheet, CRCA sheet, single door system lockable by keys, painted externally and internally with two coats of synthetic enamel grey paint (first quality) over a coat of red oxide primer complete comprising of following :- (a) Aluminium bus bar of cap not less than 100 AMps mounted on PVC insulators, length not less than 150mm (b) ALuminium bus bar should have multi holes for connectioons (c) MCB SP 6-10 Amp, Type 'C' - 01 Nos mounted on MCB channel (d) Two nos of cable gland suitable for cable 16 sqmm 4 core (e) The cut out box should be fixed with pole by 02 x MS clamp not less than 25mmx5mm with suitable nut, bolt and washer. Note :- (i) Rate quoted shall deemed to inculdes for MS clamp, nut, bolt & washer.
S&F street light junction box of size not less than 300mmx200mmx150mm, LT (415 Volts, 3 Phase, 4 wire supply), factory assembled, outdoor type, 2mm thick MS sheet, CRCA sheet, single door system lockable by keys, painted externally and internally with two coats of synthetic enamel grey paint (first quality) over a coat of red oxide primer complete comprising of following :- (a) Aluminium bus bar of cap not less than 100 AMps mounted on PVC insulators, length not less than 150mm (b) ALuminium bus bar should have multi holes for connectioons (c) MCB SP 6-10 Amp, Type 'C' - 01 Nos mounted on MCB channel (d) Two nos of cable gland suitable for cable 16 sqmm 4 core (e) The cut out box should be fixed with pole by 02 x MS clamp not less than 25mmx5mm with suitable nut, bolt and washer. Note :- (i) Rate quoted shall deemed to inculdes for MS clamp, nut, bolt & washer.
Supply and fixing in replacement mounting bracket (suitable for fixing/holding street/security light fittings) made of 40mm bore GI pipe ‘light grade’ 1.50m long, bent to shape at required angle, fixed on pole with MS clamp of size 40x5mm - 02 Nos, nuts, bolts & washers, complete all as directed. Note :- (i) Rate quoted shall deemed to inculdes for MS clamp, nut, bolt & washer.
Supply and fixing mounting bracket (suitable for fixing/holding street/security light fittings) made of 40mm bore GI pipe ‘light grade’ 1.50m long, bent to shape at required angle, fixed on pole with MS clamp of size 40x5mm - 02 Nos, nuts, bolts & washers, complete all as directed. Note :- (i) Rate quoted shall deemed to inculdes for MS clamp, nut, bolt & washer.
Supply & fixing in replacement cable PVC insulated and PVC sheathed size 2.5 sqmm 1100 Volts grade, single core multistranded aluminium conductor complete.
Supply & fixing cable PVC insulated and PVC sheathed size 2.5 sqmm 1100 Volts grade, single core multistranded aluminium conductor complete.
S&F rigid non-metallic PVC conduit 20mm dia including fixing on pole/wall with and fixing accessories such as clamps for stay, nut, bolt, hooks etc complete all as specified & directed.
Supply & fixing in replacement 16 sqmm 2 core copper conductor, XLPE insulated PVC sheathed unarmoured cable 1100 Voltrs grade complete all as specified and directed.
S&F main switch iron clad rewirable type SPN 32 Amps 240 Volt fixed on pole/ panel/ wall including making connections with and including suitable size cable of and of length as per site complete all as specified and directed.
S&F hot water PVC connection heavy duty, 450 mm long suitable for 15mm bore GI pipe including brass nuts on both sides complete all as specified.
M&L for galvanized steel water tubing medium grade of 15mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors.
S&F 15mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions.
Supply & fixing bib taps, cast copper alloy, screwed for iron pipe and fixed for 15mm bore pipe complete all as specified & directed.
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket single phase 20 A, complete with 01 No. MCB 32 Amp, SPN complete. Make :- Indo Asian Cat Part No 810393 or equivalent of makes mentioned in list of makes here-in-after .
Supply, installation & testing Geyser (water storage type) of capacity 25 litre vertical mounting type, 5 star rating, suitable for 220-240V, SP, 50 Hz AC supply fixed with & including ‘Anchor’ type /fastener type bolts & nuts (Set of 4 bolts of 10mm dia 150mm long with nuts & washers) into the wall grouted properly to hold the geyser and making good the disturbed surface as original all as per manufacturer’s instructions & as directed. Make : Cat Part "Monza Turbo" of Havellls or equivalent of makes as mentioned in Appx 'C' list of makes.
Supply, installation, commissioning and testing of MCCB 160 Amp, 415 volt, 4 pole, 25 KA breaking capacity with adjustable current range for overload protection and thermal release complete with spreader terminals (legs) and with proper lugs complete all as specified and as directed.
Supply and fixing MCB, 32 to 40 Amps, TPN, 240 Volts, 16 KA all as specified.
Supply and fixing MCB, 63 Amps, TPN, 240 Volts, 16 KA all as specified.
Supply and fixing MCB, 25 Amps, TPN, 240 Volts, 16 KA all as specified.
S & F sheet metal enclosure distribution board, double door type, three phase 415 Volts, 4 ways for MCCB, FP as incoming and MCB (TP/SP) as outgoing, comprising three phase four wire copper strip bus bar of appropriate capacity complete. Make :- The DB shall be VPTN of Indo Asian Cat Part No NVMCCB04 or equivalent of makes mentioned in Appendix 'C' in list of makes here-in-after. The connection of MCCB with cable shall be made through appropriate size pin/bottle type thimbles properly and the vacant holes of the DB shall be provided with blank plates of appropriate size. The DB shall be flush fixed and making good the distrubed surface matching with the existing specifications without any extra cost to Govt.
Supply, installation, commissioning and testing of feeder pillar board Kiosk type, LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) CPRI approved, factory assembled, plinth mounted out door type weather and vermin proof (Protection Class IP-65) made out of angle iron frame of 40 mm x 40 mm x 5 mm and 3.15 mm thick (for external) and 2 mm thick (for internal) MS Sheet ,CRCA sheet duly compartmentalized for each control MCCBs / ACB , single door system lockable by keys .The outer cell shall have both side hinged, front and back openable , double door system opening for external, rubber lining, locking arrangement, painted externally and internally with Nine tank pretreatment solution prior to a Powder coat of SIEMENS grey shade RAL 7032 (BERGER/NEROLAC ) (first quality) over a coat of red oxide primer mounted on angle iron 40x40xx5mm legs 45cm high above GL and 45cm embeded in ground with and including block of PCC (1:3:6) type C-2 of size 30x30x50cm including and comprising of following complete all as specified and directed comprising of the following :-
(a) Bus bar chamber comprising 4 nos Aluminium bus bars of capacity not less than 1.5 times of incomig/outgoing MCCBs, .All spreader terminals of MCCBs should be connected with bus bars.
(c) Outgoing (i) MCCB 4 pole , LT 415 Volts, 50 Hz Ac , 160 Amps rating and 35/36 KA rupturing capacity, thermal and magnetic setting adjustable type ( Ics=100%Icu). - 01 No (ii) MCCB 4 pole , LT 415 Volts, 50 Hz Ac , 100 Amps rating and 35/36 KA rupturing capacity, thermal and magnetic setting adjustable type ( Ics=100%Icu). - 01 No (iii) ON LOAD change over switch 415 V in sheet metal enclosure 4 Pole of Cap 200 Amps - 01 No Note:-(i) All incoming/out going cables shall be connected through suitable size gland plate /glands and these will be connected with Al Lugs of suitable size.
M & L for earthing complete with galvanized iron earth plate electrode of size 60cmx60cmx0.60cm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to the galvanized earth lead 25x4mm by means of GI bolts/nuts/ washers, protected by 40mm bore GI light grade pipe from earth plate and upto 3m along pole fixed with 2 clamps made from mild steel flat iron 25x3mm bolts, nuts and washers etc. Earth plate shall be surrounded by packed layer of coal dust 300mm and common salt 15cm thick all around bottom and top, 20mm GI medium grade pipe for watering and including funnel , wire mesh , RCC 1:2:4 type B-1 using 20 mm graded stone aggregate cover of size 30 cm X 30 cm X 8 cm thick reinforced with expanded metal weighing not less than 4Kg/Sqm, PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in earthing pit including necessary excavation and earth work, all as specified and shown in electrical plate No-3 of SSR part-I and connected to earthing point and testing on completion. Note :- PCC chamber shall be constructed at least 1.5m away from the earth electrode and pipe for watering shall be provided in slanting manners.
Disconnecting the AC and DC electric supply of voltage stabilzer servo controlled, transport to civil workshop, opening, dismantling volatge stabilizer servo contolled 3 Phase input voltage 300-480 Volts and output voltage 385-415 Volt AC supply, 50 Hz of 380 KVA to 500 KVA capacity removing unserviceable / defective parts including cleaning and servicing, top up the oil ect complete and replacement of unserviceable parts with new one, winding the coils and reassembling and transporting back at site and testing on full load complete all as specified and directed. Note :- (i) Spare parts to be replaced and oil filling to be measured and paid seperately under relevant items. (ii) The voltage stabilizer servo controlled shall be dismantle in the presence in Engineer-in-charge or his rep and list shall be prepared to the unserviceable parts and shall be kept on record. (iii) The spare parts replaced shall be of existing make or equivalent as approved.
Disconnecting the AC and DC electric supply of voltage stabilzer servo controlled, transport to civil workshop, opening, dismantling volatge stabilizer servo contolled 3 Phase input voltage 300-480 Volts and output voltage 385-415 Volt AC supply, 50 Hz of 100 KVA capacity removing unserviceable / defective parts including cleaning and servicing, top up the oil ect complete and replacement of unserviceable parts with new one, winding the coils and reassembling and transporting back at site and testing on full load complete all as specified and directed. Note :- (i) Spare parts to be replaced and oil filling to be measured and paid seperately under relevant items. (ii) The voltage stabilizer servo controlled shall be dismantle in the presence in Engineer-in-charge or his rep and list shall be prepared to the unserviceable parts and shall be kept on record. (iii) The spare parts replaced shall be of existing make or equivalent as approved.
S & F in replacement of servo control card of existing size and make.
S & F in replacement of Voltmeter of size 96mmx96mm square flush type mounted with three way as per existing make.
S & F in replacement of Ammeter of size 96mmx96mm square dial flush pattern having dial range of suitable capacity with three way as per existing make.
S & F in replacement dimmer of motor 10 Kg as per existing.
S & F in replacement of transformer 24 Volts as per existing.
S & F in replacement of gear of teeth as per existing.
M&L for rewinding of coil of gauge 150 Amps as per existing.
S & F in replacement of low and high cut off of transformer 24 volts as per existing.
S & F in replacement of SPDT switch as per existing.
S & F in replacement of relay as per existing.
S & F in replacement of pot switch as per existing.
S & F in replacement of LED indicating lamp as per existing.
S & F in replacement of volt meter of size 72 x 72mm square flush mounted as per existing.
S & F in replacement of motorised plate as per existing.
S & F in replacement of hexa for motorised plate as per existing.
Supply and top up the transformer oil.
S & F in replacement of dimmerstat complete with carbon brush and holder as per existing.
S & F in replacement of push button as per existing.
M/S D.N Choudhary
M/s INDER CONSTRUCTION COMPANY
M/S KAVITA CONSTRUCTION
SAINI ELECTRIC STORE
fauji electric works
VERMA BROTHERS
YASHU CONTRACTORS
S K CONTRACTOR
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .