Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹24.0 L+₹4.2 L (21.2%)Rejected-AOC | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹27.2 L+₹7.4 L (37.5%)Rejected-AOC | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹27.7 L+₹7.9 L (40.1%)Rejected-AOC | L4 | Rejected-AOC Other than lowest bidder | |
| 5 | L5₹35.4 L+₹15.7 L (79.4%)Rejected-AOC 499 A VIDHYUT NAGAR A AJMER ROAD JAIPUR 302021 | JAIPUR | JAIPUR | RAJASTHAN | 302021 | L5 | Rejected-AOC Other than lowest bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
4 Mar 2020, 6:00 pmClosed
GE(S) Jaipur
GE(S) Jaipur, MES, Kalyan Marg, Bani Park, Jaipur-302006
MANNING AND OPERATION OF STP NO 1, 2, 3 THROUGH OUTSOURCING AND ITS ALLIED WORKS UNDER AGE E/M II OF GE SOUTH JAIPUR
2020_MES_320066_1
GE (S)J-53P/2019-20 8544/ /E8
Open Tender
Civil Works
Item Rate
335 days
GE(S) Jaipur
Category D a(ii), b(i ) and d (v)
9 documents required · 9 mandatory
₹500
Yes
GE(S) Jaipur
₹60,000
Yes
26 Mar 2020
30 Jan 2020
6 Mar 2020
30 Jan 2020
4 Mar 2020
12 Feb 2020
30 Jan 2020 - 6 Feb 2020
Amount
Manning and operation of Sewage treatment plant 600 KLD at Hameed Vihar by providing 01 (One) FGM in each shift. Operation consists of two shift in a day (each shift shall be 8 hours of duration) i.e. from 0600 hours to 1400 hours & 1400 hours to 2200 hours on all working days including Sundays and holidays all as specified and directed by the Engr-in-charge :-
Manning and operation of Sewage treatment plant 300 KLD at Pratap Line by providing 01 (One) FGM in each shift. Operation consists of two shift in a day (each shift shall be 8 hours of duration) i.e. from 0600 hours to 1400 hours & 1400 hours to 2200 hours on all working days including Sundays and holidays all as specified and directed by the Engr-in-charge :-
Manning and operation of Sewage treatment plant 600 KLD at Queens road by providing 01 (One) FGM in each shift. Operation consists of two shift in a day (each shift shall be 8 hours of duration) i.e. from 0600 hours to 1400 hours & 1400 hours to 2200 hourson all working days including Sundays and holidays all as specified and directed by the Engr-in-charge. [Note for srl item No 1, 2 & 3 :- The details of operation of above mentioned sewage installations also comprising the following works :- (i) Operation of sewage plant and pumping set timing as directed by Engr-in-Charge. (ii)Installation shall be maintained and operated in two shifts including Sunday & Holidays. (iii) Operation of pumps and opening of sluice valves at collection well to supply the raw material to sewage treatment plant time to time as laid down or as directed by Engr-in-Charge. (iv) The contractor shall be responsible to keep the sewage installation neat and clean on every day including 15 mtrs all around the installation and maintain seasonal flower/decorative plants in front of pump house. (v) Carry out tightening of nuts & bolts, replace whenever required, applying gland packing and greasing. (vi) One opreator shall always be present in each shift. In case of absent of any operator the penalty @ Rs 2000.00 per day per shift shall be imposed on the contractor.
Taking out Non clog sewage lifting pump set of Cap 5.0 HP, 3 phase, 415 volts, 50Hz, AC supply along with pipe from the sewage collection well after disconnecting electric connection, dismentling of pump and motor, repairing/ replacing defective parts as ordered and re-assembling and testing including replacing worn out nuts, bolts, washers , mechanical seal ,'O' ring gasket complete and lowering the same after repairing and making electrical and delivery pipe connections complete all as specified and directed for replacement of u/s parts if any as supply only under item Note :-Lubricant oil shall be measured and paid for separately under appropriate item and transportation if any shall be deemed to be included in quoted rate of this item
Supply only ball bearing as per existing No ( Make : NBC/SKF).
Rewinding the stator with super enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles etc.
Taking out Non clog sewage lifting pump set of Cap 7.5 HP to 12.5 HP, 3 phase, 415 volts, 50Hz, AC supply along with pipe from the sewage collection well after disconnecting electric connection, dismentling of pump and motor, repairing/ replacing defective parts as ordered and re-assembling and testing including replacing worn out nuts, bolts, washers , mechanical seal ,'O' ring gasket complete and lowering the same after repairing and making electrical and delivery pipe connections complete all as specified and directed for replacement of u/s parts if any as supply only under item Note :-Lubricant oil shall be measured and paid for separately under appropriate item and transportation if any shall be deemed to be included in quoted rate of this item
Supply only ball bearing as per existing No ( Make : NBC/SKF).
Rewinding the stator with super enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles etc.
Taking out Raw sewage lifting (submersible) pump set of Cap 12.5 HP, 3 phase, 415 volts, 50Hz, AC supply along with pipe from the sewage collection well after disconnecting electric connection, dismentling of pump and motor, repairing/ replacing defective parts as ordered and re-assembling and testing including replacing worn out nuts, bolts, washers , seal , gasket complete and lowering the same after repairing and making electrical and delivery pipe connections complete all as specified and directed for replacement of u/s parts if any as supply only under item Note :-Spare parts required for replacement shall be measured and paid for separately and cost of taking out old, fixing new and transportation if any shall be deemed to be included in quoted rate of this item
Supply only, stainless steel pump shaft.
Supply only, gun metal impeller with neck key, distance bush.
Supply only ball bearing ( Make : NBC/SKF).
Rewinding the stator with super enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles etc.
Dismantling of monoblock pump set (Filter feed pump) after disconnecting from power mains & pipe line of Capacity 5 - 7.5 HP, 3 phase, 415 volts, 50Hz, AC supply & re connect to pipe line & power mains after carrying out repairs if any under item Note :-Spare parts required for replacement shall be measured and paid for separately and cost of taking out old, fixing new and transportation if any shall be deemed to be included in quoted rate of this item
Supply only, stainless steel pump shaft.
Supply only, gun metal impeller with neck key, distance bush.
Supply only ball bearing ( Make : NBC/SKF).
Rewinding the stator with super enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles etc.
Dismantling of centrifugal pump set (Sewage treated water pump) after disconnecting from power mains & pipe line of Capacity 15 HP, 3 phase, 415 volts, 50Hz, AC supply & re connect to pipe line & power mains after carrying out repairs if any under item Note :-Spare parts required for replacement shall be measured and paid for separately and cost of taking out old, fixing new and transportation if any shall be deemed to be included in quoted rate of this item
Supply only ball bearing ( Make : NBC/SKF).
Supply only, stainless steel pump shaft.
Supply only, gun metal impeller with neck key, distance bush.
Rewinding the stator with super enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles etc.
Dismantling of centrifugal pump set (Sewage treated water pump) after disconnecting from power mains & pipe line of Capacity 25 HP, 3 phase, 415 volts, 50Hz, AC supply & re connect to pipe line & power mains after carrying out repairs if any under item Note :-Spare parts required for replacement shall be measured and paid for separately and cost of taking out old, fixing new and transportation if any shall be deemed to be included in quoted rate of this item
Supply only, stainless steel pump shaft.
Supply only, gun metal impeller with neck key, distance bush.
Supply only ball bearing ( Make : NBC/SKF).
Rewinding the stator with super enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles etc.
Dismantling of Root Air blower of capacity 20 HP , 3 phase, 415 volts, 50Hz, AC supply after disconnecting from power mains & pipe line and reconnecting the same after carrying out repairs under if any under item Note :-Spare parts required for replacement shall be measured and paid for separately and cost of taking out old, fixing new and transportation if any shall be deemed to be included in quoted rate of this item
Supply only ball bearing ( Make : NBC/SKF).
Supply only fan belt size (B-52,65)
Rewinding the stator with super enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles etc.
M&L for topping up/replacement of Engine Oil for pump blower Make :- Servo/HP
Labour only for checking the srviceability of the different spares/ component/ parts of the starter and motor pump set/ panel of any capacity at any site complete all as directed by Engr-in-charge
Supply and fix in repair DOL starter, suitable for upto 3 HP 1 phase , 415 volts AC supply motor complete all as specified and directed.
Supply and fix in repair of fully automatic star delta starter 10 HP (MUG-10) comprising of combo volt and ammeter single phase preventor, over load relay and timer housed in MS sheet power coated enclosure up to 10 HP Capacity complete all as specified and directed.
Supply and fix in repair starter of 5 HP (MR-G3) comprising of combo volt and ammeter, over load relay in MS sheet power coated enclosure complete all as specified and directed.
Cleaning/sweeping of preimises STP 1,2,3 including cutting out green vegetation, roots, bushes, Tree branches ,picking polothineand other unwanted material from the installation area and maintaining the ground surrounding the installation and removing the same out side the defence area as directed by Engr in charge. The approx area of installation to be kept clean are as under. (1) STP No 1 -6000Sqm (2) STP No -02 - 4900 Sqm (3) STP-3 - 5100 Sqm Note :- (i) if contractor fail to the clean the area of installation or found absent than recovery @ 3000/- each job shall be recovered from his dues and contractor's claim on this account shall not be entertained. (ii) Contractor provide required T&P like as(Broom, Axe,saw,boucket etc) (iii) Each job shall be completed in 02 month.
Supply and fix in replacement of MCCB of the following sizes complete all as specified and directed :- Make - L&T/Havells/HPL/C&S/ LEGRAND
MCCB TP 160 Amp, 35 KA,Type DNO, 415 Volts, 50 Hz.
MCCB TP 100 Amp, 16 KA, Type DNO, 415 Volts, 50 Hz.
MCCB TPN 63 Amp, 16 KA, Type DN0, 415 Volts, 50 Hz.
M&L for Replacement of change over switch 100 Amps 415 V , 4 pole side handle type complete all as specified and directed . Make - L&T/Havells/HPL/C&S/ LEGRAND
M&L for Replacement of U/S contactor of MNX 9 complete all as specified and directed. Make - L&T/Havells/Siemens/C&S/ LEGRAND
M&L for Replacement of U/S contactor of MNX 18 complete all as specified and directed. Make - L&T/Havells/Siemens/C&S/ LEGRAND
M&L for Replacement of U/S contactor of MNX A2 complete all as specified and directed. Make - L&T/Havells/Siemens/C&S/ LEGRAND
M&L for Replacement of U/S Bimetal over load relay range 4.5 - 7.5 /6.0 - 10 Amps, 415 Volts complete all as specified and directed by Engr-in-charge. Make- L&T/ABB/.AE/siemens
M&L for Replacement of U/S Bimetal over load relay range 9.0 - 15 Amps, 415 Volts complete all as specified and directed by Engr-in-charge .Make- L&T/ABB/.AE/siemens
M&L for Replacement of U/S Bimetal over load relay range 14 - 23 Amps, 415 Volts complete all as specified and directed by Engr-in-charge. Make- L&T/ABB/.AE/siemens
M&L for Replacement of u/s electronic timer 0 - 60 sec complete all as specified and directed. Make C&S/L&T /Havells/Standered
M&L for Replacement of u/s single phase preventor complete all as specified and directed. Make- L&T/ABB/SEIMENS
M&L for Replacement of u/s MCB TPN 32 Amps, 415 volts complete all as specified and directed. Make - L&T/Havells/HPL/C&S/ LEGRAND
M&L for Replacement of u/s MCB TPN 40 Amps, , 415 volts complete all as specified and directed. Make - L&T/Havells/HPL/C&S/ LEGRAND
M & L for replacement of U/S sluice valves,class PN 1.6 of undermentioned type and size with cast iron body with forged brass spindle, non rising type and cast iron wheel head, both ends flanged, IS-14846 marked comlete with neoprene rubber gasket ,jointing material and incl nuts/bolts/washer of suitable size etc complete all as specified and directed.
100 mm bore
150 mm bore
M & L for non return valves,class PN 1.6 of undermentioned type and size 100 mm dia with cast iron body and both ends flanged, ISI marked comlete with neoprene rubber gasket ,jointing material and incl nuts/bolts/washer of suitable size etc complete all as specified and directed .
S & F in repair detachable joints suitable for CI/DI /HDPE pipe complete with rubber rings nut, bolts, excavation and earthwork, cutting of pipe etc of following sizes complete all as specified and directed .
80 mm dia
100 mm dia
150 mm dia
200 mm dia
M & L for replacement of U/S Butterfly valve 100 mm dia, ISI marked,complete with all fittings/accessories, required for fixing complete all as specified and directed
M&L for replacement of U/S foot valve cast iron of size 150 mm flanged type with all accessories complete all as specified and directed by Engr-in-charge
Supply and laid in trenches High density polyethylene pipes (HDPE), PE 80 grade and nomi nal pressure (PN 6)rating 6 Kgf/cm of size 63 mm complete all as specified and directed.
Supply and laid in trenches High density polyethylene pipes (HDPE), PE 100 grade and nominalpressure (PN6) rating 6 Kgf/cm of size 110 mm complete all as specified and directed.
Supply and laid in trenches High density polyethylene pipes (HDPE), PE 100 grade and nominal pressure(PN6) rating 6 Kgf/cm of size 160 mm complete all as specified and directed.
Supply and laid in trenches High density polyethylene pipes (HDPE), PE 100 grade and nominal pressure(PN6) rating 6 Kgf/cm of size 200 mm complete all as specified and directed.
Excavation & earth work in trenches n.exc 1.5m wide and n.exc 1.5m in depth and getting out in soft and loose soil including trimming of sides and bottom of trenches complete all as specified and directed.
Returning, filling-in, including spreading, watering and well ramming in layers n.exc 25cm thick each in soft/loose soil complete all as specified and directed.
Removing excavated surplus soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
M & L for replacement of 3- layer PP-R (Polypropylene Random Copolymer) concealed pipes SDR 7.4 PN 16 UV stabilised and antimicrobial fusion welded having thermal stability for sewage treated water supply and including all types required fittings with PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed of the following sizes :- Note : Wall thickness of pipe shall be as per IS 1580 (Make- ZINDAL/ SFMC / KANHA PLASTIC PVT LTD )
75 mm dia
50 mm dia
25 mm dia
15 mm dia
Supply and spay of chemical for unwanted wild grass chemical apply with spray machine etc all as directed by engr in charge. Make: Glyhosate 41 SL or equivalent by GE
Taking out Non clog sewage lifting pump set of Cap 5 to 12.5 HP, 3 phase, 415 volts, 50Hz, AC supply along with pipe from the sewage collection well and removeing mud, plastic ,cloth,poleythen ,stone etc complete and testing than lowering the same after cleaning complete all as specified and directed
Desludging underground sewage sump (Raw well) at Pratap line ,Hameed Vihar & Queens road of internal dia 9.5 meter and depth upto 8.5 meter and removing away sludge to a distance not less than 150 meters including burying sludge into pits and covering pits with excavated earth and including cleaning of pump house inside and surrounding all around up to complete fencing of sewage installation by removing of all vegitation, bushes, mud, dirt, dust etc and shift to a distance not exceeding 150 meter including applying two coats of white wash internally after preparation of surface, complete all as specified and directed by the Engineer in Charge. Note : Cleaning period between each unit 5 months
Desludging (MBBR ) sewage Tank at STP of internal dia 6.5 meter and depth upto 7.5meter and removing away sludge to a distance not less than 150 meters including burying sludge into pits and covering pits with excavated earth and including cleaning of pump house inside and surrounding all around up to complete fencing of sewage installation by removing of all vegitation, bushes, mud, dirt, dust , refilling of PVC media filter after cleaining/washing with water or chamical etc and shift to a distance not exceeding 150 meter including applying two coats of white wash internally after preparation of surface, complete all as specified and directed by the Engineer in Charge.
Desludging (Equlizer and Greasas ) sewage Tank at STP of size 9x3.5x3 mtr meter and removing away sludge to a distance not less than 150 meters including burying sludge into pits and covering pits with excavated earth and including by removing of all vegitation, bushes, mud, dirt, dust ,cleaining/ washing with water or chamical etc including applying two coats of white wash internally after preparation of surface, complete all as specified and directed by the Engineer in Charge.
Cleaning/ servicing of existing (carbon , Raw & Sand ) filter at STP and removing away sludge to a distance not less than 150 meters and refilling of PVC media filter after cleaining/washing with water or chamical etc complete all as specified and directed by the Engineer in Charge. Note :- (Item No. 44 to 47) Sump/Tank not clean by mannual(with manpower) only cleaning Machine stricly followed (a) Quoted rates shall also include for excavation of pits for burying sludge and removing of surplus soil to a distance not exceeding 150 meters. (b) T&P, labour & transportation charges etc is deemed to be included in the quoted rates. (c ) The complete sludge to be removed for which adequate man power, T&P, sludge removing vibrator and sludge carrying vehicle including diesel driven non-clog pump set for pumping out the sewage / sludge to be made available with in the overall cost of the quoted rate. (d) Necessary arrangements viz pipeline, pumpset, starter etc. should also be made for pumping out of the daily receiving sewage from the nearby manhole of raw sewage sump to JDA line till the time the cleaning of raw sewage completely carried out for which cost shall be deemed to be included in the quoted rate of the item.
M&L for water high pressure gauge including socket welded to measure pressure in the delivery pipe 0-150 Psi Kg / Cm2 Make - FE/BIG/ Guru, RAMCO
Supply and laying under ground cable, XLPE LT armoured heavy duty with aluminium conductor of size 35 Sqmm 3 ½ core including taking down old unserviceable cable.
Disconnecting exisitng LT over heated or burnt cable terminal / joint at panel/fidder piller & LT cable of any size culting out over heated/ burnt/ unserviciable portion of cable, stretching/ opening cable to suitable required length etc and fixing aluminium lugs / joint material and suitable nuts bolts & washer etc all as direeted by Engr-in-charge
Supply and fix in repair cooper cables PVC insulated over all sheathed flat ISI marked of size 10 sqmm, 3 core, 1100 volts grade complete all as specified and directed.
Supplying, laying, jointing and testing ductile iron pressure pipe centrifugally cast ISI marked with socket and spigot ends with jointing materials conforming to IS 8329/2000 standard length , of k7 specification with out zinc coating laid in trenches, under floor,road etc of150 mm dia sizes incl taking down Make -Jindal ltd/Electrosteel Casting Ltd/Tata Metalinks
M&L ductile iron fittings, IS-1538 marked viz bends, tapers, reducers, tee pieces (single or double branch) any type, angle / radius and straight connecting pieces, but all ends flanged, size of pipe upto 150 mm bore, complete all as specified.
Supply of UCTECH -01 ( liquid floculant ) using for the de- established colloidal particales together to form large aggregates of Sewage water ,dozing 2.5 kg/50 ppm per day (for two times ) and using at the time of peak water flow in a Settling Tank complete all as specified and directed. Make : Urveeka Chemteck Pvt Ltd, or euivalent make as approved by GE
Supply only bleaching powder grade-I having chlorine content 35% dry and white free flowing powder without hard lumps and impurities and easily soluble in water. The material should not contain more than 0.3% moisture particle size passing through - 1.70 mm IS sieve and stability loss of chlorine should be maximum 1/15th. Make:- As approved by GE
Supply of UCTECH -02( liquid coagulant )using for neutralizing the non - settleable particles & allow to form clumps of Sewage water ,dozing 2.5 kg/50 ppm per day (for two times ) and using at the time of peak water flow in a Settling Tank complete all as specified and directed. Make : Urveeka Chemteck Pvt Ltd, or euivalent make as approved by GE
Supply of UCTECH -04 ( liquid disinfectant ) using for deal with bacterial problem and make fare color of water ,dozing 4 kg/80 ppm per day (for two times ) and using at the time of peak water flow in a Holding Tank complete all as specified and directed. Make : Urveeka Chemteck Pvt Ltd, or euivalent make as approved by GE
Supply of UCTECH -03( liquid deodprizer ) using for stop biological fouling in working zone and make odorless water to provide healthy environment of Sewage water ,dozing 3 kg/60 ppm per day (for three times ) and using at the time of peak water flow in a CollectionTank complete all as specified and directed. Make : Urveeka Chemteck Pvt Ltd, or euivalent make as approved by GE
Supply of UCTECH -07 (Nutrient chemical ) using for maintain the pH in 7-8 range to sustain quality of water as per pollution control norm of water , dozing 5 kg in a week (for two times ) and using at the time of peak water flow in a Aeration Tank complete all as specified and directed. Make : Urveeka Chemteck Pvt Ltd, or euivalent make as approved by GE
Testing report of STP treated water through Govt approved Lab for chemical parameters checking including chloride, florides,PH,Hardness and TDs. The test report confirm to IS 10500 (2012)
Supply and fix of line diagram board of STP and equipment specification board fix on front each and every equipment of STP 1,2&3 as directed by Engr in charge complete
KARNI CONSTRUCTION COMPANY
Lakshmi Enterprises
Ms Hari Deva Builders
DIVYA ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .