| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹19.0 L+₹36,286 (1.95%)Rejected-Finance WARD NO 16 HOUSE NO 66 SALLIAN TALAB UDHAMPUR 182 101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹19.0 L+₹37,393 (2.01%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹20.9 L+₹2.3 L (12.6%)Rejected-Finance R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹23.9 L+₹5.3 L (28.6%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | slathia construction works L4 | DAVINDER SINGH L5 | jaima electricals L7 | ANIKET TRADERS L1 | LUXMI ELECTRONIC WORKS L2 | VISHWA MITTAR PACHYALA L3 | PROACH ASSOCIATES BUILDERS & ENGINEERS L6 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down after shutdown and disconnecting existing primary/secondary side of repairable transformer of capacity upto 630 KVA indoor /outdoor type and removing/ taking down for repair from existing cable and including earth wire all as specified and directed by Engr-in-Charge.
NOTE :-(i)The contractor shall return the transformer duly repaired with in 20 days other wise a penalty of Rs 1000/- per day will be recovered from the firm.
(ii) All type of T &P i.e Hydra etc for lifting of transformer and safely equipment shall be provided by the contractor. | 10 | Each | 5,000 ₹50,000 | 3,000 ₹30,000 | 1,000 ₹10,000 | 1,500 ₹15,000 | 600 ₹6,000 Lowest | 603 ₹6,030 | 3,000 ₹30,000 |
| 2.00 | M&L for Shifting including loading unloading and transporting to contractor workshop/ authorised workshop of transformer of size 63 to 630 KVA capacity with suitable arrangement i.e hydra, crane etc and after complete repair of transformer and transporting it from contractor’s workshop to working site including testing etc and reconnecting with existing primary power cable and secondary power cable side & earthing of transformer after taking shut down and including testing & commissioning on existing load in the presence of rep of sub division and re-testing at site as per norms and direction of Engr-in-Charge
Note :- Winding wire and other items/spares and new transformer oil mentioned in above will be measured and paid separately. | 10 | Each Job | 5,000 ₹50,000 | 5,000 ₹50,000 | 2,000 ₹20,000 Lowest | 2,000 ₹20,000 Lowest | 9,600 ₹96,000 | 9,650 ₹96,500 | 5,000 ₹50,000 |
| 3.00 | M & L for shifting/Placing standby transformer in the place of defective transformer which is under repair including loading /unloading, transportation and reconnecting incoming and outgoing cable along with earth wire including testing at site etc all as specified and directed by Engr-in-charge. | 10 | Each Job | 5,000 ₹50,000 | 3,000 ₹30,000 | 1,500 ₹15,000 | 1,000 ₹10,000 Lowest | 3,600 ₹36,000 | 3,650 ₹36,500 | 6,000 ₹60,000 |
| 4.00 | Winding the transformer of size 63 KVA to 630 KVA suitable for secondary original size copper wire complete with all required insulation/ varmishing materials complete all as specified and directed by Engineer-in-Charge. | 300 | Kg | 600 ₹1,80,000 | 1,000 ₹3,00,000 | 800 ₹2,40,000 | 800 ₹2,40,000 | 496 ₹1,48,800 Lowest | 500 ₹1,50,000 | 690 ₹2,07,000 |
| 5.00 | Winding the transformer of size 63 KVA to 630 KVA suitable for primary original size copper wire complete with all required insulation/ varnishing materials complete all as specified and directed by Engineer-in-Charge. | 430 | Kg | 700 ₹3,01,000 | 1,000 ₹4,30,000 | 800 ₹3,44,000 | 800 ₹3,44,000 | 496 ₹2,13,280 | 495 ₹2,12,850 Lowest | 690 ₹2,96,700 |
| 6.00 | Winding the transformer of size 63 KVA to 630 KVA suitable for secondary original size aluminium wire complete with all required insulation/ varnishing materials complete all as specified and directed by Engineer-in-Charge. | 250 | Kg | 200 ₹50,000 Lowest | 400 ₹1,00,000 | 250 ₹62,500 | 250 ₹62,500 | 396 ₹99,000 | 390 ₹97,500 | 300 ₹75,000 |
| 7.00 | Winding the transformer 63 KVA to 630 KVA suitable for primary original size aluminium wire complete with all required insulation/ varnishing materials complete all as specified and directed by Engineer-in-Charge . | 300 | Kg | 300 ₹90,000 | 400 ₹1,20,000 | 250 ₹75,000 Lowest | 250 ₹75,000 Lowest | 396 ₹1,18,800 | 388 ₹1,16,400 | 300 ₹90,000 |
| 8.00 | S & F in repair secondary stud bush rod of brass complete with nuts bolts and washers of brass for 63 to 100 KVA transformer complete all as specified and directed by Engineer-in-Charge | 6 | Each | 600 ₹3,600 | 400 ₹2,400 | 400 ₹2,400 | 100 ₹600 Lowest | 160 ₹960 | 170 ₹1,020 | 690 ₹4,140 |
| 9.00 | S & F in repair secondary stud bush rod of brass complete with nuts bolts and washers of brass for 160 to 250 KVA transformer complete all as specified and directed by Engineer-in-Charge | 5 | Each | 600 ₹3,000 | 700 ₹3,500 | 1,000 ₹5,000 | 100 ₹500 Lowest | 160 ₹800 | 170 ₹850 | 700 ₹3,500 |
| 10.00 | S & F in repair secondary stud bush rod of brass complete with nuts bolts and washers of brass for 300 to 400 KVA transformer complete all as specified and directed by Engineer-in-Charge | 5 | Each | 600 ₹3,000 | 700 ₹3,500 | 1,000 ₹5,000 | 100 ₹500 Lowest | 160 ₹800 | 170 ₹850 | 900 ₹4,500 |
Tender Value
₹37.8 L
EMD Value
₹76,000
Closing Date
20 Oct 2025, 6:00 pmClosed
HQ CWE AF Jammu
HQ CWE (AF) JAMMU AIR FORCE STATION JAMMU
CA NO CWEAFJ-21/2025-26 REPAIR/MAINTENANCE OF 11KV/33KV POWER AND DISTRIBUTION TRANSFORMER ALONGWITH SERVO VOLTAGE STABILIZERS AND CONNECTED WORKS AS SUCH DEHYDRATION TESTING COMMISSIONING ETC AT AF STATION UDHAMPUR UNDER GE (AF) UDHAMPUR
2025_MES_731455_1
CWEAFJ-21/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
UDHAMPUR
AS PER NIT AND TENDER DOCUMENT
9 documents required · 9 mandatory
₹500
GE AF Udhampur
₹76,000
Yes
29 Apr 2026
18 Sept 2025
22 Oct 2025
18 Sept 2025
20 Oct 2025
6 Oct 2025
Amount
Taking down after shutdown and disconnecting existing primary/secondary side of repairable transformer of capacity upto 630 KVA indoor /outdoor type and removing/ taking down for repair from existing cable and including earth wire all as specified and directed by Engr-in-Charge. NOTE :-(i)The contractor shall return the transformer duly repaired with in 20 days other wise a penalty of Rs 1000/- per day will be recovered from the firm. (ii) All type of T &P i.e Hydra etc for lifting of transformer and safely equipment shall be provided by the contractor.
M&L for Shifting including loading unloading and transporting to contractor workshop/ authorised workshop of transformer of size 63 to 630 KVA capacity with suitable arrangement i.e hydra, crane etc and after complete repair of transformer and transporting it from contractor’s workshop to working site including testing etc and reconnecting with existing primary power cable and secondary power cable side & earthing of transformer after taking shut down and including testing & commissioning on existing load in the presence of rep of sub division and re-testing at site as per norms and direction of Engr-in-Charge Note :- Winding wire and other items/spares and new transformer oil mentioned in above will be measured and paid separately.
M & L for shifting/Placing standby transformer in the place of defective transformer which is under repair including loading /unloading, transportation and reconnecting incoming and outgoing cable along with earth wire including testing at site etc all as specified and directed by Engr-in-charge.
Winding the transformer of size 63 KVA to 630 KVA suitable for secondary original size copper wire complete with all required insulation/ varmishing materials complete all as specified and directed by Engineer-in-Charge.
Winding the transformer of size 63 KVA to 630 KVA suitable for primary original size copper wire complete with all required insulation/ varnishing materials complete all as specified and directed by Engineer-in-Charge.
Winding the transformer of size 63 KVA to 630 KVA suitable for secondary original size aluminium wire complete with all required insulation/ varnishing materials complete all as specified and directed by Engineer-in-Charge.
Winding the transformer 63 KVA to 630 KVA suitable for primary original size aluminium wire complete with all required insulation/ varnishing materials complete all as specified and directed by Engineer-in-Charge .
S & F in repair secondary stud bush rod of brass complete with nuts bolts and washers of brass for 63 to 100 KVA transformer complete all as specified and directed by Engineer-in-Charge
S & F in repair secondary stud bush rod of brass complete with nuts bolts and washers of brass for 160 to 250 KVA transformer complete all as specified and directed by Engineer-in-Charge
S & F in repair secondary stud bush rod of brass complete with nuts bolts and washers of brass for 300 to 400 KVA transformer complete all as specified and directed by Engineer-in-Charge
S & F in repair secondary stud bush rod of brass complete with nuts bolts and washers of brass for 630 KVA transformer complete all as specified and directed by Engineer-in-Charge
S & F in repair primary stud bush rod of brass complete with nuts bolts and washers of brass for 63 to 100 KVA transformer complete all as specified and directed by Engineer-in-Charge
S & F in repair primary stud bush rod of brass complete with nuts bolts and washers of brass for 160 to 250 KVA transformer complete all as specified and directed by Engineer-in-Charge
S & F in repair primary stud bush rod of brass complete with nuts bolts and washers of brass for 300 to 400 KVA transformer complete all as specified and directed by Engineer-in-Charge
S & F in repair primary stud bush rod of brass complete with nuts bolts and washers of brass for 630 KVA transformer complete all as specified and directed by Engineer-in-Charge
S & F in repair temperature gauge (circular dia type) of standard size and suitable for indoor/outdoor type transformers upto 630 KVA capacity complete all as specified and as directed by Engineer -in-Charge.
S & F in repair replacement breather assembly of standard size filled with silica-gel for transformer upto 630 KVA complete all as specified and directed by Engineer-in-Charge.
Material and Labour for dehydration/centrifuging of transformer of capacity upto 630 KVA to make the oil fit for reuse or oil as per standard procedure upto strength level 60 KV all including Oil topping up (new oil for toping/or for replacement shall be measured and paid separately) etc complete all as specified and directed by Engineer-in-Charge.
Supply and filling of new transformer oil of ISI marked for transformer for topping up levels or for replacement of unfit oil having electric strength not less than 60 KV and shall be confirming to IS 335 complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair primary bush insulator brass rod of transformer of capacity upto 63 to 100 KVA complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair primary insulator of transformer of capacity upto 160 to 250 KVA complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair primary bush insulator of transformer of capacity upto 300 to 400 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair primary bush insulator of transformer of capacity upto 630 KVA complete all as specified and directed by Engineer-in-Charge.
S & F in repair of secondary bush insulator of transformer of capacity upto 63 to 100 KVA complete all as specified and directed by Engineer-in-Charge.
S & F in repair of secondary bush insulator of transformer of capacity upto 160 to 250 KVA complete all as specified and directed by Engineer-in-Charge.
S & F in repair of secondary bush insulator of transformer of capacity upto 300 to 400 KVA complete all as specified and directed by Engineer-in-Charge.
S & F in repair of secondary bush insulator of transformer of capacity upto 630 KVA complete all as specified and directed by Engineer-in-Charge.
S&F in replacement tap changer moving contact assembly complete for transformer rating upto 63 KVA to 160 KVA, including connecting up with HT coil and testing for varying voltage complete all as directed and specified by Engineer-in-Charge.
-Ditto- all as per item No 28 above but for transformer of capacity 200 KVA and upto 315 KVA.
-Ditto- all as per item No 28 above but for transformer of capacity 400 KVA to 630 KVA.
M & L for silica gel (deep sky blue colour) for replacement in breathers of indoor/outdoor type transformer complete all as specified and directed by Engineer-in-Charge.
M&L for painting of the transformer complete removal of old paint and applying two coat of spray painting with approved synthetic enamelled paint of capacity as under :-
Transformer of capacity 400 KVA.
Transformer of capacity 300 KVA.
Transformer of capacity 200 KVA.
Transformer of capacity 160 KVA.
Transformer of capacity 100 KVA.
Transformer of capacity 63 KVA.
Taking up proper shut down of existing switch yard and disconnecting up the LT and HT electric mains from transformer of capacity 3.15 MVA removing the lid/cover, bush/stud, gasket,rectify oil leakage of transformer and oil seal of bushing for inspection at site and to facilitate minor repairs after draining out the transformer oil, reassembling the transformer, refilling the transformer oil (new or old) & centrifusing/ dehydration of transformer oil and being topping up ,installing, commissioning and testing at site complete all as specified and directed by Engineer-in-Charge. Note:- All spare parts required to be replaced during maintenance shall be measured and paid separately. (ii) New Tranformer oil for topping up shall be measured and paid separately.
S & F in repair new breather dully filled with activated agent ie silica gel for transformer of capacity upto 3.15 MVA complete all as specified and directed by Engineer-in-Charge.
S & F in repair replacement LV bushing (11 KV side) of 33 KV transformer complete with brass/tinned copper rod including nuts, gasket, check nuts and washers complete matching with existing make and type both end threaded of transformer outdoor rating to 3.15 MVA in replacement, complete all as specified and directed by Engineer-in-Charge.
S & F in repair replacement HV bushing (33 KV side) of 33 KV transformer complete with brass/tinned copper rod including nuts, gasket, check nuts and washers complete matching with existing make and type both end threaded of transformer outdoor rating to 3.15 MVA in replacement, complete all as specified and directed by Engineer-in-Charge.
M & L for transformer platform of size 3.0 x3.0 x 1m high from GL including excavation and earth work in trenches in any type of soil,PCC 1:5:10 type E2 for foundation, brick work in cm 1:6 PCC, 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in coping, plaster of 10mm thick in cm 1:6 on brick surface/complete with 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in sub base of floor with topping of, PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate 100 mm thick in floor and finished fair(without using extra cement) returning filling in and removal of surplus to a distance n.exc 50m chain link fencing for the transformer platform of 1.8 m high made out of 4 mm dia GI wire 150x100 mm mesh with MS angle iron 50x50x6mm as in fencing post and embedded in PCC 1:2:4 type B-1 30X23X30cm block at 2 m interval each side as approved with 1 No steel gate (3.5 m clear) span with locking arrangement made out of 15 mm dia MS rod 50x50x6mm angle iron frame and painting the steel surface with 2 coat of aluminium paint over a coat of red oxide primer and 2 coats of white washing on cement work complete all as specified and directed by Engineer-in-Charge.
M&L Earthing complete as per electrical plate No 5 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0 mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to and including galvanised iron or steel earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing strip protected by galvanised iron or steel pipe 50 mm bore medium grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil, charcoal, salt, funnel , PCC pit and RCC cover complete all as specified & directed by Engineer-in-Charge. Note 1- Following items deemed to be included in quoted rate :- (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal, dust, common salt and ground enhacement material as required to bring the earthing resistance as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
M&L Earthing complete as per electrical plate No 5 of MES SSR Part I with copper earth plate earth electrode 60 cm x 60 cm x 3.15 mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.8 m below normal ground level connected to and including copper earthing strip 20 x 3 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 50 mm bore medium grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil, charcoal, salt, funnel , PCC pit and RCC cover complete all as specified & directed. Note 1- Following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. ( for neutral of Transformer)
S&F for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles with the help of insulator or any other indicated situation for loop earthing etc and provision of brass/copper nuts, bolts washers etc wherever required and making joints as required 32 x 6 mm galvanised iron strip complete all as specified and directed by Enginer-in-Charge.
Supply and fix end joint kit for 11 KV grade cable for outdoor/indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 50 to 95 sqmm including taking down old. NOTE:- Item rate quoted including required T&P/Refixing & Refilling in the panel/pole.
Supply and fix end jointing kit for 11 KV grade cable for outdoor/indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 120 to 185 sqmm including taking down old. NOTE:- Item rate quoted including required T&P/refixing & refilling in the panel/pole.
Supply and fix cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 50 to 95 sqmm including taking down old. NOTE:- Item rate quoted including excavating/required T&P/Refixing & Refilling.
Supply and fix cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 120 to 185 sqmm including taking down old. NOTE:- Item rate quoted including excavating/required T&P/Refixing & Refilling.
S&F in repair of steel tubular, swaged pole, 11 Mtr long type 410-SP-55 complete with cast iron base plate, finial taper plug, bolts, nuts and screws duly painted with two coats anti corrosive paint internally complete and externally upto planting depth alternate black and yellow straps of synthetic enamel paint 30 cm each up to 1.5 mtr from GL and remaining pole painted with aluminium paint including writing No complete all as specified and directed by Engineer-in-Charge.
M & L for PCC 1:3:6 type C2 with using 40 mm crushed stone graded aggregate as in foundation of broken transformer plinth/ pole with necessary form work complete as specified and directed by Engineer-in-Charge.
M&L for type PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in coping etc for broken transformer plinth /pole including necessary form work complete all as specified and directed by Engineer-in-Charge.
M & L for 10 mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finish surfaces even and smooth without using extra cement, complete all as specified and as directed by Engineer-in-Charge.
M&L for disconnecting burnt end portion of 95 sqmm to 120 sqmm 3 core cable removing the cable from loop including necessary excavation, earthwork, removing brick protection and relaying the same, and reconnecting the cable by removing burnt portion of cable/ transformer/panel/pole etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair and testing and commissioning of air break gang operated switch, triple pole mechanically operated out door type with all fittings/accessories mounted on and including 11 KV HT 15 Nos porcelain insulators of rating up to 200 Amps complete with drop out fuse assy having fuses of rating 40 Amps and steel channel frame, GI operating rod 25 mm dia of suitable length with operating mechanism worked form ground level, vertically operated including locking arrangement & operating handle, with and including padlock complete all as specified and as directed by Engineer-in-Charge.
S&F in repair for cross arms, bracings supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed by Engr-in-Charge.
S&F in repair of lightning arresters expulsion type complete (Each Set -03 Nos ) with all fittings, transmission class, discharge capacity 65 kilo amp and hight current with stand 100 KA outdoor type for 11000 volts, including clamps, nuts and bolts, washers and connection to earth wire 4 mm GI strip to Lightning arrester complete all as specified and directed by Engineer-in-Charge.
M&L in repairs MS angle iron of size 40x40x4 mm powder coated for holding of MS sheets in cable duct all as specified and directed.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out in soft/loose or any type of soil including boulder for taking up or laying of cable complete all as specified and directed by the Engineer-in-Charge.
Excavation in trenches exceeding 1.5 meter wide and not exceeding 3.0 meter deep and getting out in soft/loose or any type of soil including boulder for taking up or laying of cable complete all as specified and directed by the Engineer-in-Charge.
Returning filling in soils including spreading, leveling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removing surplus soil to a distance not exceeding 50 meter and sepositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and directed by Engineer-in-Charge..
Supply and laying new dry sand or dry coarse sand as cushioning to cable 8 cm below the cable and 15 cm above the cable and punned to 18 cm as cable cushioning and coverning all as specified and as directed by Engineer-in-Charge. Note:- Punned quantity will be measured and paid at this item.
Supply and laying in replacement of un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40 mm complete all as specified and directed by Engineer-in-Charge.
S&F GI tube light grade of size 50 mm with all fittings laid in trenches or fixed to walls or fixed in above the existing strip and ceiling or laid in floor for cable crossing complete all as specified and directed by Engr in charge including taking down old..
S&F GI tube light grade of size 80 mm with all fittings laid in trenches or fixed to walls and ceiling or laid in floor for cable crossing complete all as specified and directed by Engr- in-charge including taking down old.
M & L for cutting of Road and Concrete surfaces upto 300 mm depth and 200 mm wide for laying of cable / pipe in any type of soil, returning and filling in and spreading, leveling, watering and well ramming in layers not exceeding 25cm thick removal of surplus soil and provision of 150 mm thick PCC type B-1, 1:2:4 with 20mm graded crushed stone aggregate on top layer all as specified and as directed.
Supplying, laying, jointing, testing and commissioning HT under ground electric power cable cossed linked polyethylene (XLPE) insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor, 11000 Volts grade suitable for earth system of 3 core 95 Sq mm cross sectional area size, ISI marked as per IS 7098 Part-2, laid in trenches/ laid under floor/ laid in ducts or fixed on poles etc. complete all as specified and directed.
Taking down and re-laying of HT cable of any size after rectify the fault or laying of XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 11000 Volt grade, 3 Core 95 Sqmm to 3 Core 185 Sqmm including jointing and testing, laid in trenches / ducts / pipe or on poles complete all as specified and directed.
Supply and laying cable duct cover of size 600 mm deep and 450 mm wide including MS sheet of 8 mm thick for protection of HT cable (which lying above the ground) in main receiving station running from indoor RMU/VCB towards two pole structure and furthur transformers connected through it finished properly as directed by Engineer-in-Charge. Note : Rate of brick work shall deemed to be included in the quoted rate.
M&L in repair stainless steel chain link fencing for housing of transformer of existing size of minimum lenght 10 ft and height 6 ft , 8 gauge tying along with angle iron of size 50x50x6 mm grouted with necessary PCC/civil work including cost of material , Gi binding wire for tie MS bolts & net ,fixing and finishing in all respects including two coat of aluminium paint that complete all as specified and directed.
LUXMI ELECTRONIC WORKS (BID ID -3449807)
VISHWA MITTAR PACHYALA (BID ID -3449952)
slathia construction works (BID ID -3446232)
DAVINDER SINGH (BID ID -3455549)
PROACH ASSOCIATES BUILDERS & ENGINEERS (BID ID -3448459)
jaima electricals (BID ID -3449738)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
TENDERDOCU21.pdf
Tender Documents • 1.18 MB
BOQ_818925.xls
BOQ • 10.60 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .