| 3 | L3₹10.0 L+₹2.1 L (26.1%)Rejected-Finance RAMA PARK A 121 BLOCK A UTTAM NAGAR WEST DELHI DELHI 110059 | DELHI | WEST DELHI | DELHI | 110059 | L3 | Rejected-Finance Other than lowest tender | |
| 4 | L4₹11.7 L+₹3.8 L (48.1%)Rejected-Finance GALI NO 5 6 H NO 6 275 JHARODA MAARA EXTN PART III BURARI NEW DELHI 110084 | NEW DELHI | CENTRAL DELHI | DELHI | 110084 | L4 | Rejected-Finance Other than lowest tender |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
31 Jul 2020, 6:00 pmClosed
GE (N) DELHI CANTT-10
GE (N) DELHI CANTT-10
REPAIR MAINT OF EXTERNAL WATER SUPPLY SYSTEM INCLUDING REPAIRS TO VARIOUS MOTOR PUMP SETS REPLACEMENT OF PIPE LINES CLEANING OF UG SUMP AND OTHER CONNECTED WORKS AT KWC TIMARPUR UNDER GE N DELHI CANTT
2020_MES_358403_1
GE/NORTH-20/2020-21
Open Tender
Civil Works
Works
180 days
GE (N) DELHI CANTT-10
as per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (N) DELHI CANTT-10
₹24,000
Yes
31 Aug 2020
4 Jul 2020
1 Aug 2020
4 Jul 2020
31 Jul 2020
18 Jul 2020
Amount
SCHEDULE 'A' SECTION-I: Excavation in trenches not exceeding 1.5 mtr depth width and not exceeding 1.5m depth for laying pipes in loose/soft soil all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm all as specified and directed.
Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed.
Supply, laying, jointing & testing of GI Pipe, medium grade, including all fittings in old/new position, laid in trenches/ wall including taking down the old/unsv pipe line complete all as specified & directed of following sizes (Make- Jindal/ TATA/ BST) :- (Note : Excavation and earth work shall be measured and paid separately under respective items of schedule)
80 mm dia
50 mm dia
40 mm dia
25 mm dia
20 mm dia
15 mm dia
S&F in repair gun metal, globe or gate valve, screwed down high pressure with iron wheel head, screwed both ends complete for the following sizes of pipes :-
(a) 50 mm dia
(b) 40 mm dia
(c ) 25 mm dia
(d) 20 mm dia
(e) 15 mm dia
Supply, laying, jointing and testing of Cast Iron Pipe with spigot & socketed end, centrifugally cast, Class LA push on joint laid in trenches in old/ new route as required at site including taking down the old/unsv pipe line complete all as specified & directed of following sizes:-
(a) 100 mm dia
(b ) 80 mm dia
Drilling and tapping cast iron water mains (in position) for branch connections of following internal dia including necessary fittings and mild steel brackets of suitable size complete :-
(a) 15 mm bore
(b) 20/25 mm bore
M&L for run lead joint in spigot and socketted pipe including spun yarn complete all as specified and directed for following sizes of pipes :-
(a) 80mm dia
(b) 100mm dia
M& L for cast iron bends (any type, radius and angle) tapers any type (straight, bend, increasing decreasing or double socket etc) tee piees, single branch, 'Y' junction, double branch cross (all sockets or socket & spigot) collars, caps and plugs for spigot socketed pipes upto 150 mm bore complete.
M&L for cast iron sluice valve of pressure class PN-1.6 type flanged and drilled at both ends, conferming to ISI mark and having gun metal spindle and rings including wheel for operating all as specified including two numbers flanged socket and jointing materials such as bolts, nuts, washers, rubbers/ fibre board gasket including taking down old unserviceable valve from pipe line of both ends complete of following sizes:-
(a) 100 mm dia
(b) 80 mm dia
M&L for bailing out the water from the semi underground/UG sump capacity upto 10,000 GLNS with out causing any interruption to regular water supply system and cleaning the same walls, roof and floor thoroughly by using wire brush/scrapper for removal of deposited scales/sludge/silt etc and removing the materials out of site cleaning thoroughly with water and bleaching powder and then by chlorine solution for complete anti bacterial disinfections with applying one coat of white wash inner and outer side including writing date of cleaning on the black board with white paint all as specified and directed (Note:- Rates quoted deemed to be inclusive of T&P and safety equipments required at site)
M&L for bailing out the water from the semi underground/UG sump capacity 20,000 GLNS with out causing any interruption to regular water supply system and cleaning the same walls, roof and floor thoroughly by using wire brush/scrapper for removal of deposited scales/sludge/silt etc and removing the materials out of site cleaning thoroughly with water and bleaching powder and then by chlorine solution for complete anti bacterial disinfections with applying one coat of white wash inner and outer side including writing date of cleaning on the black board with white paint all as specified and directed (Note:- Rates quoted deemed to be inclusive of T&P and safety equipments required at site)
M&L for PVC ball valves high pressure of PTMT with epoxy coated Aluminium rod & highd ensity plastic ball complete assembly screwed for iron pipe and fixed and taking out UNSV complete for the following sizes :-
S&F in repair MS chequred plated of 6mm thick including provision of lifting handle for each plate on existing trenches/ manhole covers for semi under ground sumps according to site condition including painting of synthetic enemel black paint over one coat of primer complete all as directed
M & L for construction of brick masonary valve pit chamber of size 1050x1050x1050 mm (internal dimension) including necessary excavation and earthwork, PCC, brick work,12 mm thick rendering in cement mortar 1:4 on internal surface of valve pit and mild steel sheet cover 3mm thick and mild steel angle iorn frame size 40 x 40 x 5 mm around of valve pit, locking arrangement with pad lock of size 50 mm brass, 6 leavers and key (Make : Godrej) complete including two coat of synthetic enamel over a coat red oxide primer on steel surface with preparation of surface and including dismantling of existing valve pit complete all as specified & directed.
All as per above item but size 900x900x900 mm
M & L for writing letters or figures (Block, Roman, Italic or Indian) n exc. 30 cm high with synthetic enamel paint on existing steel RCC/ wall surface as per colour scheme all as specified.
M&L for spray painting of complete water Pumpset of any type up to 10 HP capacity with two coats of synthetic enameled paint of specified colour after preparation of surface complete
M&L for painting of water supply pipes net works consisting of valves of any type and size at various pump houses inlcuding duly scrapping thoroughly the existing corroded paint / dirt/ dust / rust and preparing the surface and applying two coats of synthetic enamel paint over a coat of red oxide primer as per the colour code and marking the water flow directions on pipe lines as directed.
(a) 80 mm bore
(b) 100 mm bore
Supply only bleaching powder stable of 33% chlorine all as specified (Make : DCM/RMCO/Rayalaseema or equivalent)
Material & labour for earthing with Galvanised Steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using GI strip of size 25 X 4mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 5 of SSR 1991(Part-I) complete
Supply only gland packing with wire rope 1/4 " 1/2"
Supply only rubber insertion sheet 4mm thick
M&L for Disconnection electrical and water connection of the centrifugal pump and motor 10 HP with base plate and transported to work shop opening carefully and replacement of bushes, gland packing, ball bearing, rubber gasket nut and bolt fixing the require new parts(parts such as shaft, impellor, coupling & bearing shall be supplied under relevant item of schedule ) and complete re-fixing its in original position and making out all electrical and water connection and testing complete (Note :- Rate includes transportation of motor from the place of installation for repairing and reinstalling the same on existing foundation, testing & commisioning)
Supply only shaft suitable for centrifugal pumps for 10 HP
Supply only GM impellor suitable for centrifugal pumps for 10 HP
Supply only MS coupling suitable for centrifugal pumps for 10 HP
Supply only bearing suitable for centrifugal pumps for 10 HP
M&L for rewinding of electrical motor with super enameled copper winding wire of suitable size not less than original after cutting and taking out old winding complete with all insulation material such as colton top varnish etc of centrifugal pump set motor 10 HP complete
M&L for Disconnection electrical and water connection of the induction motor with base plate and transported to work shop opening carefully and replacement of bushes, gland packing, ball bearing, rubber gasket nut and bolt including two coat of synthetic enameled paint over a coat of red oxide primer fixing the require new parts (parts such as shaft impeller and coupling bearing shall be supplied under relevant item of schedule) and complete re-fixing its in original position and making out all electrical and water connection and testing complete for the following size/ capacity of motors (Note :- Rate includes transportation of motor from the place of installation for repairing and re-installing the same on existing foundation, testing & commisioning) :-
Supply only shaft suitable for induction motor pumps for the following sizes :-
Supply only bearing suitable for induction motor pumps for the following sizes :-
M&L for rewinding of electrical motor with super enameled copper winding wire of suitable size not less than original after cutting and taking out old winding with all insulation material such as colton top varnish etc of centrifugal pump set motor complete all as specified and directed for the following sizes :-
S&F fully automatic star delta starter appx full load with necessary relay and air break contactor complete type with incoming and outgoing connection complete including taking down existing complete all as directed of size/rating ML-1.5 at load of 20-32 Amps
S&F 3 pole power contactor ML-1.5 for starter incl taking down old one complete
S & F single phase preventor for 3 phase motors fixed for star delta starters complete
S&F Volt meter (0-500 volt) square/round digital type incl taking down old one complete
S&F Amp meter (0-100) square/round digital type incl taking down old one complete
M & L for preparation of old painted steel or iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coat of synthetic enameled paint of approved shade complete
S&F MCCB 4 Pole, 415 volt, 36 KA of following capacity on existing panel including removing old one complete (Make : Legrand/ L&T/ Havells/ Schneider) :-
(a) 250 amps, 36 KA, adjustible type
(b) 200 amps, 36 KA, adjustible type
(c ) 100 Amps, 16 KA, fixed type
(d) 63 Amps, 16 KA, fixed type
M&L for servicing of DG set capacity 10 KVA, 3 phase, 415 Volt, 50 Hz including carrying out maintenance and check alongwith following repairs including replacement of worn out parts :- (a) Replacement of lubricating oil (b) Replace Engine Oil filter cartridge with New one. (c) Cleaning /Descaling /Callibration of Deisel fuel tank and writing date of cleaning complete (d) Renew fuel filter cartridge with New one. (e) Check tightness of all nuts and bolts. (f) Check adjustment of V belt for driving engine water pump and alternator. (g) Assembling complete old serviceable parts and replacement of old unserviceable parts by new one as per direction. (h) Servicing of radiator (j) Cleaning of air cleaner filter and renew after period of hrs run as specified by manufacture. (k) Checking complete exhaust system including examining puncture in the mufler and redoing the complete insulation for adequate noise and pollution reduction complete (l) S&F MS pipe medium grade to be connected by welding with existing exhuast pipe 40mm dia/same size dia matching to existing size of 5 mtr length (approx) up to outside of wall of genset room for provisioning flow of flue gas outside of genset room incl making hole for pipe at wall to kept pipe outside of room with fixing arrangement incl painting with back synthetic enamel paint over one coat of primer complete all as directed by Engr-in-charge. (m) Testing of DG set after repair & servicing for smooth running of DG Set as per Manufacturers Instructions as directed by Engr-in-charge. Note:- Any minor parts as required at site shall be supplied by the contractor. Cost for the same shall be deemed to be included in the unit rate quoted.
S&F maintenance free battery 12 volt, 150 AH and depositing old battery to MES store complete (Make:- Exide/Amaron)
S&F in repair battery lead of copper conductor cable 50 sqmm X 1 mtr with lugs complete
S&F in repair battery brass terminal complete
S&F functional conventional type water level indicator for UG sump consisting of the following complete all as directed:- (a) Water lavel indicator height (as per sump/tank depth) up to 6mtrs, 150mm width fabricated out of 3 mm thick MS sheet and angle iron frame of 40mm x 40mmx3mm duly painted with two coats of synthetic enamel paint of approved shade over a coat of red oxide primer and marking the letters in white glossy paint and suitable size of letters / Number is not less than 5". (b) S&F of new copper float ball of 300 mm and MS pointer connected with SWR ropes through brass pully fixed on angle iron support with necessary fabrication and welding work so as to slide and indicate the water level in the sump .
S&F in repair LED Post top lantern luminaire with die cast aluminium spigot, lid cover and clear acrylic cover 40 watt, 5700 K with IP-65 protection incl connection complete (Make :Crompton cat Pt No LPTO-40-CDL or equivalent in Havells/Philips/Wipro)
S&F in repair LED flood/security light fitting of 30 watts with pressure die-cast aluminium housing complete with all accessories, fixing of fitting on wall with necessary fixing arrangement as required at site & connection complete (Make : Surya / Polycab / C&S)
Supply only Calcium Hypo Chlorite 65% to 70% granules as specified (Make : Aquafit or equivalent as approved)
Supply only Chlorination testing kit incl solution, glass vessels tubular type etc complete all as specified and directed
Chemical, Boilogical, Potability Testing of water sample at Govt recognised/approved institute/Lab for potability and chemical analysis complete all as specified & directed. (Schdule of Credit - 28105.00)
J.P. Enterprises
HANUMAN BUILDERS
QUALITY CONSTRUCTIONS CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .