| 1 | L1₹31.8 LAccepted-AOC | ₹31.8 L Quoted ₹35.8 L | L1 | Accepted-AOC L1 |
| 2 | L2₹40.2 L+₹4.4 L (12.3%)Rejected-Finance 26 8 2 PUNE MUMBAI ROAD OPP B U BHANDARI SHOWROOM EKTA PARK SOCIETY WAKDEWADI PUNE 411 003 | PUNE | MAHARASHTRA | 411003 | ₹40.2 L+₹4.4 L (12.3%) | L2 | Rejected-Finance not being lowest |
| 3 | L3₹42.4 L+₹6.6 L (18.5%)Rejected-Finance FLAT NO 107 C WING SKYWAYS SERENO LOHEGAON PUNE 411 047 | PUNE | PUNE | MAHARASHTRA | 411047 | ₹42.4 L+₹6.6 L (18.5%) | L3 | Rejected-Finance not being lowest |
| 4 | L4₹44.4 L+₹8.6 L (24.2%)Rejected-Finance | ₹44.4 L+₹8.6 L (24.2%) | L4 | Rejected-Finance not being lowest |
Tender Value
₹49.3 L
EMD Value
₹98,560
Closing Date
13 Jan 2023, 6:00 pmClosed
Garrison Engineer (CME) Kirkee
Garrison Engineer (CME) Kirkee, Phugewadi, Dapodi, Kendriya vidyalay Gate , beside Unlimited (Mega Mart) Mall, Pune - 411 012
Special repair to Bldg No.T-221 and plinth protection along with drains of Bldg No.194 at CME, Pune
2022_MES_569553_1
8369/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer (CME) Kirkee
Class D, category a(i)
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer (CME) Kirkee
₹98,560
Yes
10 Mar 2023
16 Dec 2022
20 Jan 2023
16 Dec 2022
13 Jan 2023
31 Dec 2022
17 Dec 2022 - 30 Dec 2022
Amount
Dismantling of single layer Mangalore Pattern roof tile laid dry complete all as specified and directed
All as per item No.1 above, but bedded in lime or cement mortar complete all as specified and directed.
Dismantling battens for tiles, shingles etc, of any size including tilting fillets spacing not exc 15 cm complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed.
M&L for second class hardwood wrought in scantling fixed in framed work complete all as specified and directed.
S&F Framed work such as roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe-410-W (Gde E-250) Quality A complete all as specified and directed.
S&F rolled sections as in main and cross beams, hips and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc Fe-410-W (Gde E-250) Quality A complete all as specified and directed.
M & L Preparation of new or previously untreated surfaces of iron of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over and including one coat red oxide zinc chrome primer complete all as specified and directed
Dismantling Plain or Corrugated Steel Sheeting of any gauge or similar pattern Roof Coverings complete all as specified and directed
S&F 0.63mm thick galavanised, corrugated mild steel sheeting with two corrugations side laps, fixed with 'L' hook or 'J' hook bolts in roofs walls etc with grade of zinc coating 275 complete all as specified and directed.
S&F 0.63mm thick plain galvanised mild steel sheeting in ridges, hips, valley, gutters, drips and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed.
M&L for roof tiles, Mangalore Pattern, interlocking at side joints laid dry complete all as specified and directed.
All as per item No.12 above, but except tile complete incl washing of tiles.
M&L for ridge tiles, Mangalore Pattern of roof tiles, set and jointed in CM 1:6 complete all as specified and directed.
Taking down chowkats or frames with shutter (without taking off shutters from the frames) not exc. 1.5 sqm each and removing from sitecomplete all as sepcified and directed.
All as per item No.15 above, but exc. 1.5 sqm and not exc. 4 sqm complete all as specified and directed.
S & F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
S&F aluminium colour powder coated anodised door and shutter single or double leaf glazed/pre laminated board exterior quality partly glazed//pre laminated board exterior quality party glazed panels fabricated including aluminium anodised beading rubber and packing materials and shall be drilling in existing wall and thrust bolt suitable size complete comprising the following:- (a) Aluminium colour anodised door frame section 101.60x44.45x1.93 mm fixed as per spd (b) Aluminium colour anodised vertical section in shutter 85x44.45x2 mm as per spd. (c) Aluminium colour anodised Top & style shutter section 95.25x44.45x2.00 mm as per spd. (d) Aluminium colour anodised handle 02 Nos in each shutter 200 mm long as spd. (e) Aluminium colour anodised middle lock rail/bottom rail section 150x44.2.65mm cat No.20002. Make-Jindal (f) Floor spring Make-Sandhu, (g) Six lever mortice lock brass Make : Godrej/Classic on in each door (h) 12 mm thick particlular board (pre laminated both face) exterior grade ISI Marked. (j) Tinted glass/Plain glass (Colour) 5mm thick Make : Saint gobain midgaurd. Note : If ground requirement for full glass or full Panel contractor should provide as per direction of Engr-in-Charge.
S & F Mild steel butt hinges medium weight, cold rolled, 100mm, ISI marked, complete all as specified and directed.
M&L barrel tower bolts stove enamelled black of size 200 mm complete all as specified and directed.
S & F solid PVC door frame of size 50mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with M.S. square tube etc all as specified and as directed.
M & L Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing.
Demolition of brick or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
M&L precast solid block masonry of block 1:3:6 type C-1 using 20 mm graded stone aggregate as in wall exceeding 10 cm in width and built in cement mortar 1:6 complete all as specified and directed.
Taking down cement plaster on brick or stone walls or concrete surface etc including raking out joints, hacking for key, scrubbing down with water all as specified and directed.
M&L rendering 15mm thick on stone masonry surfaces in CM 1:6 finished even and smooth with sagol over and including dubbing out average 10mm thick on irregular face of walls in CM 1:6 complete all as specified and directed.
M&L rendering 5mm thick on concrete surfaces in CM 1:3 on ceiling, finished even and smooth with sagol all as specified and directed.
M&L 15mm thick cement plastering on concrete surfaces in CM (1:4) finishing surfaces even and smooth without using extra cement complete all as specified and directed.
M&L preparing newly plastered surfaces of wall and applying complete wall with 3 mm POP/Birla putty and making smooth surfaces and applying two coats of Oil bound distemper over a coat of primer all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered surfaces and applying three coats of white wash on ceiling all as specified and directed.
M&L complete removal of existing treatment and applying 3mm thick Birla wall care putty and applying two coat of Oil Bond distermper white or tinned over an coat of primer on walls, etc all as specified and directed.
All as per item No.31 above, but two coat of white wash on ceiling complete all as sepcified and directed.
M & L Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed.
Demolition of cement concrete (unreinforced ) in ground floors and pavings not exceeding 15cm thickness (below or aboved ground level) all as specified and directed.
M&L cement concrete 1:3:6 type C-2 (40mm graded stone aggregate) as in floors, plinth protection, path etc 75mm thick smooth finished surface without using extra cement including necessary form work complete all as specified and directed.
M&L for 75mm thick PCC type D-2 (1:4:8) using 40mm graded stone aggregate as in sub base etc complete all as specified and directed
Dismantling wall and ceiling boards (fibre, pulp, insulation boards/slabs/blankets) any thickness, including cover fillets
M & L for false ceiling with 4mm thick designer 'E' board fixed on GI grid work with powder coated finish on exposed surface of size 0.6 x 0.6m consisting of GI angle supported on wall of size 24mm x 28 x 0.7mm main tee of size 24mm x38mm x 0.7mm cross tee of size 24mm x 28mm x 0.7 mm using purpose made members interlocking to each other and with 40mm x 3mm flat GI mild steel strip suspender made to shape at 1200mm c/c fixed with 3mm dia GI wire and making holes etc all as directed including two coats of white wash on ceiling after preparation of surfaces and as per manufacturers instruction make of GI Grid work : Armstrong/Swastik/Techno Grid and Make E board Gypsum or equivalent approved .
M& L for Dismantling boarding, any description, fixed in any position with nails.
M&L for second class weather boarding, clean sawn, thickness 20mm to 25 mm and rebated on thick edge to give 20mm laps and fixed complete all as specified and directed.
S&F in repair 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
All as per item No.41 above, but 110mm complete all as specified and directed.
S&F in repair 75mm PVC (SWR) bend any radius complete all as specified and directed
All as per item No.43 above, but 110mm dia complete all as specified and directed.
M&L barrel tower bolts stove enamelled black of size 150 mm complete all as spd .
S&F 125mm long aluminium anodised handles or extruded section complete all as specified and directed.
S&F 150 mm long aluminium anodised handles or extruded section complete all as specified and directed.
S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple, (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast-aluminium alloy complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish off the premises complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 15 mm thick for laying floor/ wall finishes in CM 1:6 complete all as specified and directed.
M&L Non-skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc. complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface 350mmx450mmx7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over backing coat 10mm thick cement mortar in 1:4 complete all as specified and directed
Taking up or down 15mm bore steel water tubing & connections, including cleaning for refixing or offering credit as per schedule of credit complete all as specified and directed.
All as per item No.53 above, but 20mm bore
S&F 15mm bore medium grade galvanised steel water tubing with all fitting & fixed complete to walls or ceiling or laid in floors all as specifeid and directed.
S&F 20mm bore medium grade galvanised steel water tubing with all fitting & fixed complete to walls or ceiling or laid in floors all as specified and directed.
Refixing 15mm bore old steel water tubing & connection in new or old position of wall, ceiling, floor etc all as specified and directed
All as per item No.57 above, but 20mm bore.
S & F under counter wash hand basin vitreous china coloured including CI bracket, 15mm dia polythene connection, 32mm dia chromium plated (CP) waste coupling chain and plug waste filling union and 32mm dia PVC waste pipe 90cm long, all necessary inlet outlet connections complete all as specified and directed. Make : Hindware Cat No. 10065 or equivalent model in Cera /Parryware/ Neycer as approved by GE.
M & L for coupled closet (Clover) snow white make Cera including P or S trap alongwith cistern dual flush complete set and soft close plastic seat cover complete all as specified and directed including taking down old wash down water closed pan of any description any size including taking down old u/s one complete all as specified. Make- CERA Cat. No. S1013115 S Trap / P Trap or equivalent model in Parry ware (Super fine), Hindware as approved by GE.
S&F For in repair brass chromium plated two way bib cock fancy type, 15mm bore ( min Wt. 550 grams) of approved make by EIC/ GE etc. complete all as specified and directed.
S & F in repairs Health faucet (ABS Body) mild steel CP suitable for 15 mm dia pipe with 1.25 mtr long flexible tube and ABS wall hook incl making connections and fixed in postion complete all as specified and directed.
S&F in repair 15 mm dia pillar taps, cast copper alloy, with capstan heads, chromium plated fancy type , screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long shanks and flynuts, screwed for iron pipe complete all as specified and directed.
S&F PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F in repair 15mm fancy type bib tap, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed
S&F in repair 15mm dia stop valve chromium plated fancy type screwed down high pressure with crutch or butterfly handle screwed both end for iron pipe or for union complete all as specified and directed.
M&L in repair 75mm PVC (SWR) floor trap with grating including jointing with solvent cement complete all as specified and directed.
All as per item No.67 above, but 110mm complete all as specified and directed.
S&F in repair Brass chromium plated tubular towel rail, 20mm dia, D type 60cm long between flanges complete all as specified and directed.
S& F in repair Soap dish holder complete as specified and directed by Engr-in-Charge.
S&F Toilet paper holder, vitreous China, box type complete all as specified and directed.
Excavation in trenches n exc 1.5m wide and n exc 1.5m deep and making good surface for laying /removing of cable and gettingout in soft/ loose soilall as specified and directed.
All as per item No. 73 above, but in hard/ dense soil
Returning, filling in, excavated soil in trenches, watering and well ramming in layers not exc. 25 cm complete all as specified.
Removal of surplus excavated spoil to distance exc. 50 metre and not exc. 250 m depositing where directed at a level not exc. 1.5 m above, the starting point all as specified and directed
Dismantling stone slab and tiles of any description and thickness as in floor including cement mortar bedding and rubbish off the premisses complete all as specified and directed.
Demolition of Concrete in ground floors and pavings not exc. 15 cm thickness (below or above ground level) etc. complete all as specified and directed.
M & L Hardcore of guage exc. 63mm but not exc. 100 mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed.
M&L for 75mm thick PCC type D-2 (1:4:8) using 40mm graded aggregate as in sub base etc complete all as specified and directed
M&L for screed bed or bedding layer of mortar 15 mm thick for laying floor/ wall finishes in CM 1:6. complete all as specified and directed.
M&L for 20 to 25 mm thick rough dressed sand stone slab flooring, laid dry but jointed and pointed in cement mortar 1:3 etc. complete all as specified and as directed.
All as per item No.82 above, but except stone Note :- Serviceable stone obtained from sl item No.77 shall be re-used in this item.
M&L cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L precast solid block masonry of block 1:3:6 type C-1 using 20 mm graded stone aggregate as in wall exceeding 10 cm in width and built in cement mortar 1:6 complete all as specified and directed.
M&L cement concrete 1:2:4 type B-2, (using 40mm graded aggregate) as in surface channels and drain complete all as specified and directed.
M&L 15mm thick cement plastering on concrete surfaces in CM (1:4) finishing surfaces even and smooth without using extra cement complete all as specified and as directed.
M & L Reinforcement Cement concrete type B1 (1:2:4) using 20mm graded stone aggregate as in cover slab for draine & manholes etc. as directed incl use and waste of necessary form work complete all as specified and directed. Note :- Reinforcement shall be measured and paid separately
M & L MS TMT Bars 10mm dia and over cut to length, bend to shape required, incl cranking, bending, for hooping for columns, hooking ends and binding with and incl MS wire (Annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F 75 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints as in weep hloes etc. complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm in hard/dense soil complete all as specified and directed.
Removing excavated surplus soil to a distance exc. 50m but not exc. 250 m and depositing where directed at a level exc. 1.5m above the starting point
Taking down carefully copper/aluminium point wiring (light, fan,bell, socket or power) complete, including fixture and fittings such as switches, Ceiling rose, pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc . credit for above items should be made as per conditions separately.
M&L for point wiring for light/fan/Bell with FRLSH cable 1.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade in and incl not less than 2mm thick PVC casing/caping with all accessories and 1.50 sqmm green in colour PVC copper conductor cable for earth continuity connected to common earth dolly incl PVC box surface/ flush type with PVC sheet for mounting fittings such as switches, sockets, fan regulators, etc complete all as specified and directed for one light/fan /bell point controlled by one switch & making good to disturbed surface of wall etc for the following :-
One light point controlled by one switch
One fan/exhaust fan point controlled by one switch and regulator
Socket outlet, three pin 5 Amps on the same board
Socket outlet, three pin, 5 Amp, independent
All as per item No . 2 above but with 2.5 sqmm cable and 2.5 sqmm for earth continuity for multipin 15 amps socket outlet flush type on independent board.
S & F ceiling rose, 3 terminal PVC/polycarbonate isolated body, surface bakelite 65 x 50 mm, 3 terminal incl PVC square block complete all as specified and directed.
S&F switch Modular, one way 6 amps, 1 module with suitable plate and cover complete all as specified and directed.
S&F switch modular one way 16 amps, 1 module with suitable plate and cover complete as per existing make and model all as specificed and directed.
S&F socket modular 6A, 2/3 pin combined 2 module with suitable plate and cover complete as per exisisting make and model all as specificed and directed.
S&F socket modular 6A/16A, 2/3 pin combined 2 module with suitable plate and cover complete as per existing make and model all as specificed and directed.
S&F Decorative ultra slim aluminium LED lighting fixture with high lumen output, environmental friendly, energy efficient ready to use pack. surface and wall mounted LED batten(LED tube light fitting complete 22W) with polycarbonate housing & integrated electronic driver and 02 No PVC square blocks incl taking down old UNSV fitting. Make- Havells cat No LHEXACP7IN1S022 or equivalent of Philips/ Bajaj/ Wipro/ Halonix/ Jaquar/ Bentac India Ltd./ Shakti
S & F bathroom mirror light 12 watt warm white VANITY INSANITY (LARGE, BUILT-IN LED) STAINLESS STEEL VANITY LIGHT
Taking down ceiling fan of any size/sweep after disconnecting the wire from existing ceiling rose and refixing the same after cleaning dust, oiling greasing, painting, etc including providing flexible three core from ceiling rose to connector of fan all as specified and directed.
Taking down celing fan of any size after disconnecting the wire from existing ceiling rose and deposited to MES Store (AGE E/M sub divn) and Supply and fixing ceiling fans complete with blades, down rods,regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
S&F in replacement LED panel 2 feet x 2 feet size 36 watt glare free symmetrical including driver complete all as specified and directed.
Taking down of LED panel 2 x 2, 36 watt after disconnecting the wire from existing ceiling rose and refixing the same on existing position
Supply and fix exhaust fan AC single phase 230/ 240 volts of size 300 mm sweep, 1400 rpm, with louvers and all fixing arrangements such as plywood 18mm thick of suitable size all as specified and directed.
Supply and fix exhaust fan AC single phase 230/ 240 volts heavy duty of size 450 mm sweep, 1400 rpm, with louvers and all fixing arrangements such as plywood 18mm thick of suitable size all as specified and directed.
S&F load line vertical TPN distribution board 4 way including 1 incommer MCCB of 125 Amps 4 pole double door IP-43 protection, powder coated, IK08 with provision of suitable size bus bar and cable management kit complete all as specified and directed. Make : Indoasian cat part No 811888 or eqlnt in Hager/Havells/Legrand
S & F in replacement MCB distribution board double door 415 volt, TPN 4-way all as specified and directed.
S & F in replacement MCB SP 6 to 32 Amps, 230 V AC complete all as specificed and directed.
S & F in replacement MCB TPN 100 Amps,415 V, AC complete all as specificed and directed.
S & F in replacement MCB TPN 63 Amps,415 V, AC complete all as specificed and directed.
S & F in replacement MCB SPN 40 to 63 Amps, 230 V, AC complete all as specificed and directed.
S & F for sub main wiring with four run of 6 sqmm single core multi stranded PVC insulated and unsheathed copper conductor (red for phase and black for neutral) of grade 1100 volt FRLSH cable in and including 1100 volt electrical grade PVC Conduit of desired colour not less than1.2 mm thick and 25 mm wide & 6 sqmm copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete all as specified and as directed incl taking down old unserviceable one.
All as per item No.115 above, but size 10 Sqmm Four runs and with one run 10.0 sqmm FRLSH copper wire for earth continuity.
M&L for earthing complete with GI earth plate electrode 60x60cmx6mm thick burried directly in ground in earth pit not less than 2.25 mtr depth below normal ground level with top edge of the plate vertically to depth of not less than 1.5 mtr below ground level connected to & including GI lead 4 mm dia as earthing lead connecting to equipment by means of GI bolts & nuts etc with provision of charcoal and salt etc all as per electrical plate No-3 of SSR part-I 2009 including RCC cover and MS angle iron frame, watering with GI pipe 20 mm dia (medium grade) & MS funnel, concrete pit including excavation and earthwork in any strata and testing on completion etc. complete all as specified and directed by Engineer-in-charge.
M & L for bituminous road cutting to a width of 45 cm and depth 50 cm for laying of pipe for laying of UG cables and making good with PCC (1:3:6) type C1 (using 20mm graded stone aggregate) all as specified and directed.
Supplying and laying in repairs GI tubing light grade of size 80mm dia bore for encasing cables for mechanical protection , laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall/floor or along poles or as street light poles or as street light mounting bracket with complete accessories such as bends/ sockets/ reducers/ saddles incl necessary threading/drilling works all as specified and directed by Engr-in-charge.
Supplying and laying in repairs GI tubing light grade of size 50mm dia bore for encasing cables for mechanical protection , laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall/floor or along poles or as street light poles or as street light mounting bracket with complete accessories such as bends/sockets/reducers/saddles incl necessary threading/drilling works all as specified and directed by Engr-in-charge.
Supply, laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cables ( heavy duty) with stranded aluminium conductor 1100 volts grade in trenches/ passing through pipe/fixing on walls, floors etc incl connection with proper sizes lugs and gland, suitable clamp of cross sectional area 3.5core 25 Sqmm in and including taking out old one all as specified and directed.
All as per item No.121 above, but of the size 3.5 core 50 Sqmm
All as per item No.121 above, but of the size 3.5 core 70 Sqmm
All as per item No.121 above, but of the size 3.5 core 95 Sqmm
All as per item No.121 above, but of the size 3.5 core 120 Sqmm
Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 120 mm and inner dia 103 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable incl couplers & bends complete all as specified. Make : REX POLYEXTRUSION LTD or its equivalent as approved
Supply, install, connect, test and commissioning factory made, dust/vermin, weather proof self ventilated, cubical of size 1.5 x 0.50 x1.2 (Approx) with front made of and rear opening, hinged door for front,and rear with MS angle iron frame 50 x 50 x 5mm for base support, 3.15 mm thick CRCA sheet, LT panel board, (LT KIOSK), CPRI approved out door, cubicle type, floor mounted, double door with neoprene gasket and locking arrangement with canopy including painting with powder coated on steel surfaces internally & externally and provision of two Nos earth terminals on both sides , cable glands and PCC foundation with PCC 1 : 2 : 4, type B1 , and 30 cm all around the outer dimension of panel including gap for insertion of cable having bottom of panel at height of 90 cms above the ground level with cable entry glands to accommodate and including the following accessories:-
Copper bus bar rectangular 400 Amps full for phase and half for neutral and interconnection of MCCBs to Bus bar mounted on epoxy insulators with colour coding PVC sleeves.-01 job
MCCB 250 Amps, TPN, 415 Volts, 50 Hz ,50 KA- 01 No ( Incoming)
MCCB 160 Amps, TPN, 415 Volts, 50 Hz ,36KA - 01 No ( Outgoing)
MCCB 125 Amps, TPN, 415 Volts, 50 Hz ,36KA - 03 Nos. ( Outgoing)
MCCB 63 Amps, TPN, 415 Volts, 50 Hz ,36KA - 01 No. ( Outgoing)
MCB SPN 63A - 01 No.
RYB LED Indicator Lamp- Set of Three-01
Provision of cubicle to accommodate the above mentioned accessories.
Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs/thimbles on either ends of cable.
M & L for earthing complete with GI earth plate electrode of size 60 x 60 x 0.6 cms thick burried directly in ground vertically at a depth of not less than 2.25 Mtrs below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanised iron strip of 25 x 4 mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, 40 mm dia GI tubing light grade protection pipe upto test point, 20 mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 type C1 using 20 mm graded stone aggregate with pit cover of size 30x30 CM made of RCC 1:2:4, type B1 using 20 mm graded stone aggregate reinforced with 6mm dia TMT bars 15 cm c/c on both ways with suitable handle, angle iron frame of angle iron size 40 x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, removal of surplus soil and returning filling in all as required at site all as specified in electrical plate No.3 of SSR Part-I and directed by Engr-in-Charge.
(Applicable for above all items)
Contractor has to employ skilled/unskilled tradesman with adequate experience & required documents to be submitted to office.
Labour should wear contractors uniform with firm logo, failing which recovery should be made.
Minimum of 02 x teams of each trades shall be available for maint of urgent nature whenever called upon of any trade, failing which recovery will be initiated for not employing adequate labour at site.
Site clearance shall be done by contractor after finishing work and obtain the signature of occupant as the site clearance has done. The same shall be verified and put up before issue of completion certificate
All Scarps will be done with mechanical scaper
Mechanical scaper should be deposited in our store at the time of sample approval
vishalconstruction
Mukund Engineers and Contractors
N AND G CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .