Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹19.7 L+₹2.8 L (16.8%)Rejected-AOC | L2 | Rejected-AOC Other than L1 |
Tender Value
Refer Docs
EMD Value
₹45,000
Closing Date
17 Nov 2020, 6:00 pmClosed
Shri TKM Rambhal, EE
GE (W) Mathura Pin-281001
Comprehensive Maintenance / Repair of cooling appliances like AC/Desert Cooler/Water Cooler /Refrigeration/Deep freezer under GE (West) Mathura
2020_MES_387669_1
8300/964/E8
Open Tender
Civil Works
Item Rate
180 days
Mathura Cantt
As per tender Documents
9 documents required · 9 mandatory
₹500
GE (West) Mathura
₹45,000
Yes
11 Jan 2021
19 Oct 2020
18 Nov 2020
19 Oct 2020
17 Nov 2020
3 Nov 2020
Amount
M&L for servicing of split type AC of capacity 1.5 / 2 TR of any type or make by opening the condenser unit fixed on roof top and cooling unit fixed inside the building, and cleaning the complete condenser unit and cooling unit including fins and checking / testing of all parts for its serviceability, and oiling / greasing of motors, replacing worn-out bushes of blower, rectification of unusual noise, checking of refrigerant standing pressure, topping of refrigerant gas upto the required level, replacement of minor parts such as nut / bolt washers etc. and reassembling of complete unit including testing for smooth functioning complete all as specified and directed.
M&L for servicing of window type AC of capacity 1.5 / 2 TR of any type or make including cleaning of filter on front side by removing dust, cleaning the condenser including fins, blower fan motor and checking / testing of all parts for its serviceability, oiling / greasing to condenser cum blower fan motors, replacing worn-out rubber, bushes / rubber packing, rectification of unusual noise, checking of refrigerant standing pressure, topping of refrigerant gas upto the required level, replacement of minor parts such as nut / bolt washers etc. and reassembling of complete AC including testing for smooth functioning complete all as specified and directed. Note for item Nos 1.00 & 2.00 (i) Refrigerant Gas required for topping up will be measured and paid separately as supply only under respective item of this Schedule. (ii) Any spare part of AC if found defective will be measured as supply and fix in repairs under respective item of this Schedule.
M&L for servicing of Ductable type AC of capacity 8.5/11.00 TR of any type or make by opening the condenser unit fixed on roof top and cooling unit fixed inside the building, and cleaning the complete condenser unit and cooling unit including fins and checking/testing of all parts for its serviceability. and oiling/ greasing of motors, replacing worn-out bushes of blower, rectification of unusual noise checking of refrigerant standing pressure topping of refrigerant gas upto the required level replacement of minor parts such as nut/bolt washers etc and reassembling of complete unit including testing for smooth functioning complete all as specified and directed.
M&L for removing the condensing fan motor from window type A/C of 1.5 / 2.0 TR capacity, rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bush, side rubber packing and re-fixing of motor in original position with new washer nuts & bolts including testing for smooth function complete all as specified and directed.
M&L for removing the unserviceable condenser fan motor from window type A/C of 1.5/2.0TR capacity and fixing new motor in original position with new washer nuts & bolts complete all as specified and directed.
Supply and fix in repairs remote control (Micro processor base) unit suitable for split type AC 1.5 / 2 TR capacity of any make complete all as specified and directed.
T&P for shifting of Split type AC of any capacity from one site to another by completely removing it from the existing place wihout any damage,and shifting it to new site including gas charging to required level comissioning and testing it to complete all as specified and directed.
T&P for shifting of Window type AC of any capacity from one site to another by completely removing it from the existing place wihout any damage,and shifting it to new site making necessary cutting in the wall making it good, including gas charging to reqd level comissioning and testing it to complete all as specified and directed.
Supply and fix in repair suction lines copper pipes of suitable size as necessary at site complete all as specified and directed.
Supply and fix in repair Discharge lines copper pipes of suitable size as per site requirement complete all as specified and directed.
Supply and fix in repair sleeve foam insulation Protection with PVC tape Suitable for Split AC 1.5/2 TR as per site requirement complete all as specified and directed.
Supply and fix in repair 9 mm thick ply wood BWR type BB fixed for covering A / C opening with second class hard wood lipping on edge and fixed to walls as required and directed including applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for Sub main wiring with 2 runs of 6 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC conduit ISI marked 25mm dia(external) with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof and one run of 6 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Two runs of 6 Sqmm cable, one run of 6 Sqmm earth conductor and one run of PVC conduit of 25mm dia shall be measured and paid as one unit length.
M&L for Sub main wiring with 2 runs of 4 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC conduit ISI marked 25mm dia(external) with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof and one run of 4 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Two runs of 4 Sqmm cable, one run of 4 Sqmm earth conductor and one run of PVC conduit of 25mm dia shall be measured and paid as one unit length.
M&L for removing the unserviceable condenser fan motor from split type A/C of 1.5 / 2.0 TR capacity, rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bush, side rubber packing and re-fixing of motor in original position with new washer nuts & bolts complete including testing complete all as specified and directed.
M&L for removing the unserviceable condenser fan motor from split type A/C of 1.5/2.0 TR capacity, and fixing new condensing motor in original position with new washer nuts & bolts complete all as specified and directed.
Supply and fix in repair capacitor, 45/50 MFD as per existing size suitable for A/C of capacity 1.5/2 TR complete all as specified and directed.
Supply and fix in repair capacitor, 10 MFD as per existing size suitable for blower motor of A/C 1.5/2 TR capacity complete all as specified and directed.
Supply and fix in repair capacitor, 4/6 MFD as per existing size suitable for blower motor of A/C 1.5/2 TR capacity complete all as specified and directed.
Supply and fix in repair drain out pipe of split type AC of PVC, heavy duty of 15 mm dia and 1.5 mm wall thickness complete with fittings, spacer and saddles complete all as specified and directed.
Supply and fix in repair aluminium fan blade size 375mm suitable for condenser of window type AC of any capacity and complete all as specified and directed.
Supply and fix in repair PVC fan blade size 375mm suitable for condenser of window type AC of any capacity and complete all as specified and directed.
Supply and fix in repair aluminium fan blade size 375mm suitable for condenser of Split type AC of any capacity and complete all as specified and directed.
Supply and fix in repair PVC fan blade size 375mm suitable for condenser of Split type AC of any capacity and complete all as specified and directed.
Supply and fix in repair PVC fan blade size 150mm for blower of cooling side of window type AC of any capacity and complete all as specified and directed.
Supply and fix in repair relay only rating 15 Amp suitable for window type AC 1.5 / 2 TR capacity complete all as specified and directed.
Supply and fix in repair over load protector only as per existing size suitable for window type AC 1.5 / 2.0 TR capacity complete all as specified and directed.
M&L for removing the unserviceable reciprocating compressor sealed unit of any type or any make for window type air conditioner of capacity 1.5TR after cutting the copper tubing without any damage to existing parts, replacing the compressor with factory made reconditioned compressor of same make complete with erection of compressor on base with suitable capillary, filters etc jointing of copper refrigerant pipe line with and including charging of refrigerant gas to required level complete including cleaning of condenser fins, leakage, testing etc complete all as specified and directed.
All as per item No 28.00(here-in-before) but for Window type Air Conditioner 2 TR capacity.
All as per item No 28.00(here-in-before) but for Split type Air Conditioner 2 TR capacity.
All as per item No 28.00(here-in-before) but for Split type Air Conditioner 1.5 TR capacity.
M&L Removing the unserviceable Rotary compressor sealed unit of any type or make from window type air conditioner of capacity 1.5TR after cutting the copper tubing without any damage to existing parts, replacing the compressor with factory made recondition compressor of same make complete with erection of compressor on base with suitable capillary, filters etc jointing of copper refrigerant pipe line with and including charging of refrigerant gas to required level complete including cleaning of condenser fins, leakage, testing etc complete all as specified and directed.
All as per item No 32.00(here-in-before) but for Window type Air Conditioner 2 TR capacity.
All as per item No 32.00(here-in-before) but for Split type Air Conditioner 1.5 TR capacity.
All as per item No 32.00(here-in-before) but for Split type Air Conditioner 2 TR capacity.
Supply and fix in repairs thermostat as per existing size suitable for window type AC 1.5 / 2 TR capacity complete all as specified and directed.
M&L for removing the unserviceable cooling fan motor of capacity 1/35 or 1/10 HP from split type AC, rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bush and side rubber ring and re-fixing in original position complete including testing complete all as specified and directed.
M&L for removing the unserviceable cooling fan motor of capacity 1/35 or 1/10 HP from split type AC and fixing new cooling fan motor in original position with new washer nuts & bolts complete all as specified and directed.
M&L for taking down window/split AC of any capacity and checking its leakage, brazing and completely arresting its leakage including topping up gas charging and testing complete all as specified and directed.
S&F in repair cooling coil as per existing size suitable for window type AC of capacity 1.5/2 TR complete all as specified and directed.
S&F in repair PCB Plate Control card as per existing make or size suitable for 1.5/2TR capacity complete all as specified and directed.
S&F in repair Cooling coil motor DC as per existing size suitable for 1.5 TR/2 TR capacity complete all as specified and directed.
S&F PVC front grill for window type AC Capacity 1.5/2.0 Ton any make , any type complete all as specified and directed.
M&L for replacement of wiring for electric supply from indoor unit to outdoor unit of size 2.5 sqmm PVC insulated multistranded circular round cable 3 core run of 5 mtr for split AC 1.5/2 TR capacity of any type or make complete all as specified and directed.
M&L in repair control valve (copper/brass) for split type AC capacity 1.5/2.0 TR of any type or make complete all as specified and directed.
M&L for cleaning down complete body including fitting and fixture of desert cooler of capacity 3000 to 6000 Cum / hours of any make including removal of all sludges, loose paint dust, dirt etc and prepared the clean surface for painting, and applying two coats of synthetic enamel paint inside and out side surfaces and applying two coats rubber seal paint inside the water tank, including rewriting of MES No etc complete all as specified and directed.
Taking out unserviceable desert cooler fan motor single phase 230 Volts, 1400 RPM 3 speed 1 / 8 HP from desert cooler and rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bushes and reassembling and fixing in position complete all as specified and directed.
Supply and fix in repairs front grill as per existing size to desert cooler made out of PVC sheet suitable for 3000 to 6000 Cum / hrs capacity desert cooler of any make as approved by Engineer-in- Charge complete all as specified and directed.
Supply and fix in repairs PVC flexible pipe 15 mm outer dia length 1.2m long with bends or elbow complete all as specified and directed.
S&F in replacement of three speed desert cooler motor 1400 RPM, 230 Volt, 50 Hz, Copper Winding single phase with ring, side legs, necessary bolts and nuts etc ISI Marked complete all as specified and directed.
Supply and fix in repair switch piano type 230 volts, singe pole one ways 6 Amps, fixed in desert coolers complete all as specified and directed.
Supply and fix in repairs PVC insulated round copper conductor flexible three core of size 0.075 Sqmm upto 3 mtrs long with plug top 3 pin 5 Amp including necessary arrangment for fixed to desert coolers switch complete all as specified and directed.
Supply and fix in repair oil filled capacitor 4 MFD for fan motor of desert cooler complete all as specified and directed.
Supply and fix in repair side shutter (Set of three) as per existing size made out from 1.00 mm thick galvanised iron sheet suitable for 3000/4000 Cum / hrs capacity desert cooler complete all as specified and directed.
Supply and fix in repair side shutter (Set of three)as per existing size made out from 1.00 mm thick galvanised iron sheet suitable for 5000/6000 Cum / hrs capacity desert cooler complete all as specified and directed.
Supply and fix in repairs of submersible pump 220 Volts, 0.025 HP suitable for desert cooler any size any capacity with supporting plate & testing complete all as specified and directed.
Supply and fix in repairs powder coated aluminium fan blade balance type and fixing on shaft of motor suitable for desert cooler size up to 450mm sweep complete all as specified and directed.
Supply and fix in repairs PVC fan blade and fixing on shaft of motor sutable for desert cooler size up to 450mm sweep complete all as specified and directed.
Supply and fix in repairs cast iron ring of cooler fan motor with clamps suitable for desert cooler complete with nuts & bolts complete all as specified and directed.
Supply and fix in repairs PVC, 3 way distributor with nut/screw complete suitable for 15 mm PVC pipe including necessary arrangement complete all as specified and directed.
M&L for servicing of Water cooler of capacity 40/80 to 150/150 ltrs of any make checking / testing all parts for its serviceability, oiling / greasing to condensed motor,electric connections etc incl checking of refrigerant standing pressure and topping of refrigerant gas upto the required level complete including testing for smooth functioning complete all as specified and directed.
M & L for preparation of old painted surface of 40/80 Ltr capacity water cooler, externally and internally including compressor chamber, motor and applying one coat of synthetic enamel paint with spray machine including writing MES No. etc. complete all as specified and directed.
All as per item No 63.00(here-in-before) but for capacity 60/120 Ltrs.
All as per item No 63.00(here-in-before) but for capacity 150/150 Ltrs.
M & L for removing the unserviceable condensing fan motor from water cooler of capacity 40/80 ltrs capacity, rewinding the same with super enameled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bush, side rubber packing and re-fixing of motor in original position with washer nuts and bolts complete all as specified and directed
All as per item No 66.00(here-in-before) but of capacity 60/120
All as per item No 66.00(here-in-before) but of capacity 150/150
M&L for removing the unserviceable condensing fan motor from water cooler of capacity 40/80 ltrs capacity and fixing new fan motor in original position with new washer nuts and bolts complete all as specified and directed
All as per item No 69.00(here-in-before) but of capacity 60/120
All as per item No 69.00(here-in-before) but of capacity 150/150
S & F in repair aluminium fan blade size 125mm balance type suitable for water cooler of capacity 40/80 Litres complete all as specified and directed.
S & F in repair aluminium fan blade size 150mm balance type suitable for water cooler of capacity 60 / 120 Ltrs complete all as specified and directed.
S & F in repair aluminium fan blade size 225mm balance type suitable for water cooler of capacity 150/150 Litrs complete all as specified and directed.
Supply and fix in repairs 15 mm size bib tap, cast copper alloy, chromium plated push type suitable for water cooler of any capacity complete all as specified and directed.
Supply and fix in repairs starting capacitor 60/80 MFD suitable for water cooler of any capacity complete all as specified and directed.
Supply and fix in repairs running capacitor 10 MFD suitable for water cooler of any capacity complete all as specified and directed.
Supply and fix in repairs thermostat range 2 degree celcius to 15 degree celcius suitable for water cooler of any capacity complete all as specified and directed.
Supply and fix in repairs waste water adaptor PVC, 32 mm size suitable for water cooler of any capacity complete all as specified and directed.
Supply and fix in repairs relay with Over Load Protector rating 5 to 15 Amp suitable for 40 to 150 liters capacity water cooler complete all as specified and directed.
Supply and fix in repairs PVC drain out pipe, heavy duty 32/40 mm dia, wall thickness 2 mm complete with fittings such as nipple, clips etc complete fixed to water coolers of any capacity complete all as specified and directed.
Supply & fix 15 mm bore mild steel galvanized water tubing, medium grade with all fitting and accessories complete fixed to walls and ceiling or laid to floors etc including taking down old GI tubing complete all as specified and directed.
M&L for removing the unserviceable compressor sealed unit of any make/type for water cooler capacity 40 / 80 liters after cutting copper tubing without any damage to existing parts, replacing compressor with reconditioned compressor of same make complete with erection of compressor on base with suitable capillary, filter etc jointing of copper refrigerant pipe line, charging gas to required level, complete including cleaning of fins, leakage testing etc including testing for smooth functioning complete all as specified and directed. Note :- Gurantee certificate for 12 months from manufacturer shall be provided for claiming any payment.
All as per item No 83.00(here-in-before) but water cooler of capacity 60/120 Litres.
All as per item No 83.00(here-in-before) but water cooler of capacity 150 / 150 Litres.
M&L for finding out the leakage with the pressure test of the condenser or cooling coil of water cooler 150/150 litres storage/cooling capacity and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/soldering including check gas in compressor and filled the gas to required level and testing the water cooler for the entire satisfaction complete all as specified and directed.
All as per item No 86.00(here-in-before) but for water cooler of capacity storage/cooling 60/120 litres.
All as per item No 86.00(here-in-before) but for water cooler of storage/cooling capacity of 40/80 litres.
M&L for servicing of Refrigerator of capacity 100 to 310 ltrs of any make checking / testing all parts for its serviceability, oiling / greasing to condensing coil,door,freezer etc including checking of refrigerant standing pressure and tapping of refrigerant gas upto the required level complete including testing for smooth functioning complete all as specified and directed.
M&L for cutting and removing unserviceable freezer unit of refrigerator capacity 100 to 180 litres of any make, and supply and fix new freezer unit with door and chill tray including jointing, brazing, recharging of refrigerant gas and testing for smooth functioning complete all as specified and directed.
All as per item No 90.00(here-in-before) but refrigerator of capacity 210 to 290 ltrs
All as per item No 90.00(here-in-before) but refrigerator of capacity 300 / 310 litres
M&L for preparation of external old painted surface of refrigerator of capacity 100 to 310 litres of any make, including denting of minor patches and applying one coats of Duco paint with spray machine including polishing complete all as specified and directed.
Supply and fix in repairs thermostat range 0 degree celcius to 7 degree celcius as per existing size suitable for refrigerator 100 to 310 liters capacity complete all as specified and directed.
M&L for Removing the unserviceable compressor sealed unit of refrigerator of capacity 100 to 180 liters of any make, & replacing the same compressor with reconditioned compressor of same make of model complete, re-installing in original position with all accessories like relay with Over Load Protector, filter & recharging of refrigerant complete including testing for smooth functioning complete all as specified and directed.
All as per item No 95.00(here-in-before) but refrigerator of capacity 210 to 310 litres
M&L for finding out the leakage with the pressure test of the condenser or cooling coil of Rerigerator of capacity 100 to 180 litres storage/cooling capacity and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/soldering including charging the gas R-22/R-134 and testing the water cooler for the entire satisfaction complete all as specified and directed.
All as per item No 97.00(here-in-before) but refrigerator of capacity 210 to 310 litres
M&L for servicing of Deep freezer of capacity 120 to 405 ltrs of any make checking / testing all parts for its serviceability, oiling / greasing to condensed motor including replacing bushes / rubber packing / gasket and insulating material and including repairing door and replacing handle, hinges, nut, bolts, washers etc, checking of refrigerant standing pressure and topping up of refrigerant gas upto the required level complete including testing for smooth functioning complete all as specified and directed.
M&L for preparation of external old painted surface of Deep freezer of capacity 120 to 405 liters of any makes including denting of minor patches and applying one coat of Duco paint with spray machine complete all as specified and directed.
Removing the unserviceable compressor sealed unit of Deep freezer of capacity 120 liters of any make & replacing the same compressor with reconditioned compressor of the same make and model complete re-installing in original position with all accessories like relay with over load protector & recharging of refrigerant gas complete including testing for smooth functioning complete all as specified and directed.
All as per item No 101.00(here-in-before) but Deep freezer of capacity 200/205 liters
All as per item No 101.00(here-in-before) but Deep freezer of capacity 405 liters
Supply and Fix in repair metal clad box with top plug and socket with 20 A MCB SP complete all as specified and directed.
Supply & refilling in refrigerant gas R-22/R-134 for charging the all cooling appliances as when as required at site as per direction by Engr in charge.
M&L for servicing (repairing/overhauling) of voltage stablizer single phase at site/EM yard, dismantling unserviceable parts/replacement of minor parts of circuit plate & 3 way connectors etc and re-assembling and testing etc for the following capacity complete all as specified and directed :- (a) 0.5 KVA
Supply and fixed in repair of relay suitable for voltage stabilizer for the following capacity complete all as specified and directed :- (a) 0.5 KVA
Supply and fixed in repair of voltage stablizer of Amp Meter single phase (0-30 Amp) complete all as specified and directed.
Supply and Fixed in repairs voltmeter single phase (0-300 V), complete all as specified and directed.
M&L for rewinding of transformer of voltage stablizer single phase for the following capacity complete all as specified and directed :- (a) 0.5 KVA
M&L for gas charging of ductable type pakage AC of capacity 8.5 ton incluidng necessary R-22/R-134 gas, filter, anti-moisturising agent, soldering, braging necessory copper capillary tube any size and testing, complete all as specified and directed.
M&L for gas charging of ductable type pakage AC of capacity 11.0 ton incluidng necessary R-22/R-134 gas, filter, anti-moisturising agent, soldering, braging necessory copper capillary tube any size and testing, complete all as specified and directed.
Removing burnt/defective compressor unit of any make from any type of air conditioner of 8.5 ton capacity including gas charging & filter by cutting of suction and discharge lines and unscrewing foundation nuts and supply & fixing factory re-conditioned compressor unit, complete all as specified and directed.
Removing burnt/defective compressor unit of any make from any type of air conditioner of 11.0 ton capacity including gas charging & filter by cutting of suction and discharge lines and unscrewing foundation nuts and supply & fixing factory re-conditioned compressor unit, complete all as specified and directed.
S&F in repair for controller card suitable for 8.5 Ton ductable 3 Phase Air Conditioner as per existing make, size and capacity, complete all as specified and directed.
S&F in repair controller card suitable for 11 Ton ductable 3 Phase Air Conditioner as per existing make, size and capacity, complete all as specified and directed.
S&F in repair fan motor capacity 1/2 HP size 300mm sweep for indoor unit of 8.5 Ton ductable Air Conditioner as per existing make, size and capacity, complete all as specified and directed.
S&F in repair fan motor capacity 1/4 HP size 500mm sweep for outdoor unit of 8.5 Ton ductable Air Conditioner as per existing make, size and capacity, complete all as specified and directed.
S&F in repair fan motor capacity 1/2 HP size 400mm sweep for indoor unit of 11 Ton ductable Air Conditioner as per existing make, size and capacity, complete all as specified and directed.
S&F in repair fan motor capacity 1/4 HP size 600mm sweep for outdoor unit of 11 Ton ductable Air Conditioner as per existing make, size and capacity, complete all as specified and directed.
S&F in repair for 3 Phase preventer of AC of 11 Ton ductable Air Conditioner as per existing make, size and capacity, complete all as specified and directed.
S&F in repair 3 Phase preventer of AC of 8.5 Ton ductable Air Conditioner as per existing make, size and capacity, complete all as specified and directed.
S&F in replacement of expansion valve as per existing size suitable for Ductable AC 8.5/11TR capacity complete all as specified and directed.
S&F in replacement three phase contactor suitable for Ductable AC 8.5/11TR capacity complete all as specified and directed.
S&F in replacement Bimetal deefrost for double door refrigerator of any capacity and any make and any model complete all as specified and directed.
S&F in replacement timer for double door refrigerator of any capacity and any make and any model complete all as specified and directed.
Removing of old unserviciable iron legs and S&F iron leg in Desert Cooler for fixing of Motor including nuts and bolts complete all as specified and directed.
S&F in replacement desert cooler body made out bottom with 1.6mm thick and Top in 1.0mm thick with MS sheet including three set of side shutter complete all as specified and directed.
M&L for repair of water tank leakage with welding including suitable iron sheet for desert cooler including testing for water leakage complete all as specified and directed.
M&L for removing the unserviceable cooling fan motor from Deep freezer of any capacity and fixing new cooling fan motor in original position with new washer nuts & bolts of any make and any capacity complete all as specified and directed.
RAJ CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .