Servicing of VCB panels and ACB with Simulation test of electromechanical protection relays at 50 Cusec Ganga Jal WTP Pratap Vihar Ghaziabad
2022_UPJNM_752516_1
NIT No. 4077 / Vividh-7 / 303 Dated 19-11-2022
Open Tender
Electrical Works
Item Rate
15 days
At 50 Cusec Ganga Jal WTP Pratap Vihar Ghaziabad
Please Refer Tender Document
3 documents required · 3 mandatory
₹1,180
EE CD EM UP JAL NIGAM GHAZIABAD
₹4,000
16 Dec 2022
24 Nov 2022
2 Dec 2022
24 Nov 2022
1 Dec 2022
24 Nov 2022
Amount
Schedule "G"
Servicing of 6.6 KV incomer No.-1 vaccum contact breaker Siemens make, calibration and simulation test consisting of the following: (i) VCB-01 No. (ii) Electromechanical 02 O/C+1 E/F relay IDMT characteristics Alostom make- 01 No. (iii) Electromechanical definite relay Alostom make-01 No. (iv) Electromechanical instantaneous under voltage relay Alostom make-02 Nos. (v) Electromechanical trip circuit supervision relay Alostom make-01 No. (vi) Electromechanical auxiliary / master trip rely 30VDC Alostom make-01 No. (vii) APFC relay-01 No.
Servicing of 6.6 KV motor feeder No.-1 vaccum contact breaker Siemens make, calibration and simulation test consisting of the following: (i) VCB-01 No. (ii) Electromechanical 02 O/C+1E/F relay IDMT characteristics, Alostom make- 01 No. (iii) Electromechanical trip circuit supervision relay Alostom make-01 No. (iv) Electromechanical auxiliary / master trip rely 30VDC Alostom make-01 No.
Servicing of 6.6 KV 400 KVA Transformer feeder No.-1 vaccum contact breaker Siemens make, calibration and simulation test consisting of the following: (i) VCB-01 No. (ii) Electromechanical 02 O/C+1 E/F relay IDMT characteristics Alostom make- 01 No. (iii)Electromechanical instantaneous under voltage relay Alostom make-02 Nos. (iv) Electromechanical trip circuit supervision relay Alostom make-01 No. (v) Electromechanical auxiliary / master trip rely 30VDC Alostom make-01 No.
Servicing of 6.6 KV APFC feeder No.-1 vaccum contact breaker Siemens make, calibration and simulation test consisting of the following: (i) VCB-01 No. (ii) Electromechanical instantaneous under voltage relay Alostom make-02 Nos. (iii) Electromechanical trip circuit supervision relay Alostom make-01 No. (iv) Electromechanical auxiliary / master trip rely 30VDC Alostom make-01 No.
Servicing of 6.6 KV bus coupler feeder vaccum contact breaker Siemens make.
Servicing of 6.6 KV APFC feeder No.-2 vaccum contact breaker Siemens make, calibration and simulation test consisting of the following: (i) VCB-01 No. (ii) Electromechanical instantaneous under voltage relay Alostom make-02 Nos. (iii) Electromechanical trip circuit supervision relay Alostom make-01 No. (iv) Electromechanical auxiliary / master trip rely 30VDC Alostom make-01 No.
Servicing of 6.6 KV motor feeder No.-2 vaccum contact breaker Siemens make, calibration and simulation test consisting of the following: (i) VCB-01 No. (ii)Electromechanical 02 O/C+1 E/F relay IDMT characteristics, Alostom make- 01 No. (iii) Electromechanical trip circuit supervision relay Alostom make-01 No. (iv) Electromechanical auxiliary / master trip rely 30VDC Alostom make-01 No.
Servicing of 6.6 KV motor feeder No.-3 vaccum contact breaker Siemens make, calibration and simulation test consisting of the following: (i) VCB-01 No. (ii) Electromechanical 02 O/C+1E/F relay IDMT characteristics, Alostom make- 01 No. (iii) Electromechanical trip circuit supervision relay Alostom make-01 No. (iv) Electromechanical auxiliary / master trip rely 30VDC Alostom make-01 No.
Servicing of 6.6 KV 400 KVA Transformer feeder No.-2 vaccum contact breaker Siemens make, calibration and simulation test consisting of the following: (i) VCB-01 No. (ii)Electromechanical 02 O/C+ 1 E/F relay IDMT characteristics Alostom make- 01 No. (iii)Electromechanical instantaneous under voltage relay Alostom make-02 Nos. (iv) Electromechanical trip circuit supervision relay Alostom make-01 No. (v) Electromechanical auxiliary / master trip rely 30VDC Alostom make-01 No.
Servicing of 6.6 KV incomer No.-2 vaccum contact breaker Siemens make, calibration and simulation test consisting of the following: (i) VCB-01 No. (ii) Electromechanical 02 O/C + 1 E/F relay IDMT characteristics Alostom make- 01 No. (iii) Electromechanical definite relay Alostom make-01 No. (iv) Electromechanical instantaneous under voltage relay Alostom make-02 Nos. (v) Electromechanical trip circuit supervision relay Alostom make-01 No. (vi) Electromechanical auxiliary / master trip rely 30VDC Alostom make-01 No. (vii) APFC relay-01 No.
Servicing of 6.6 KV Transformer 800 KVA VCB Crompton make calibration and simulation test of under voltage / over voltage relay, 03 O/c + 1 E/F relay.
Servicing of 33 KV HT incomer panel including calibration & simulation test of relays as below: (i) Electromechanical 02 O/C+1E/F relay-01 No. (ii) Master Trip relay-01 No.
Servicing of 33 KV HT outgoing panel No.1 including calibration & simulation test of relays as below: (i) Electromechanical 02 O/C+1E/F relay-01 No. (ii) Electromechanical NCT relay-01 No. (iii) Electromechanical Bucchloz relay-01 No. (iv) Electromechanical WTI relay-01 No. (v) OTI relay-01 No. (vi) Master Trip relay-01 No.
Servicing of 33 KV HT outgoing panel No.2 including calibration & simulation test of relays as below: (i) Electromechanical 02 O/C+1E/F relay-01 No. (ii) Electromechanical NCT relay-01 No. (iii) Electromechanical Bucchloz relay-01 No. (iv) Electromechanical WTI relay-01 No. (v) OTI relay-01 No. (vi) Master Trip relay-01 No.
Servicing of 415 volt incomer ACB 2000 Amp. L&T make inlcluding simulation test of LT power supply from D.G. set and 800 KVA Power Distribution Transformer.
Servicing of 415 volt LT panel ACB 2000 Amp. L&T make inlcluding simulation test of LT power supply from incomer ACB and then distribution to entire plant.
Servicing of 415 volt Motor feeder 300 KW. 415V ACB 2000 Amp. Schneider make inlcluding simulation test of LT power supply from LT panel supply.
Servicing of 415 volt LT panel designated to power transformer 400 KVA, ACB 800 Amp. L&T make inlcluding simulation test of LT power supply from 400 KVA Power distribution Transformer.
Servicing of 33 KV VCB panel situated close to meter panel including cleaning, calibration and simulation test of under voltage / over voltage relay and over current earth fault relay and restoration of power control wiring from outdoor CTs / PTs
AV Enterprises
A S L ENTERPRISES
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .