Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79.8 LAccepted-AOC 59 100 AJIT NAGAR GATE KHERIA AGRA 282008 | AGRA | AGRA | UTTAR PRADESH | 282008 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹80 L+₹15,531 (0.19%)Rejected-Finance 147 WEST ARJUN NAGAR AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance Being higher bidder | |
| 3 | L3₹80.7 L+₹84,289.19 (1.06%)Rejected-Finance A 91 DEFENCE COLONY AGRA CANTT AGRA UP PIN 282001 | AGRA | UTTAR PRADESH | 282001 | L3 | Rejected-Finance Being higher bidder | |
| 4 | L4₹84.9 L+₹5.0 L (6.31%)Rejected-Finance | L4 | Rejected-Finance Being higher bidder | |
| 5 | L5₹86.6 L+₹6.7 L (8.44%)Rejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | L5 | Rejected-Finance Being higher bidder |
Tender Value
₹1 Cr
EMD Value
₹1.8 L
Closing Date
26 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Agra
HQ CWE (AF) Agra PIN 282008
ADDN/ ALTN TO SMALL ARMS RANGE AT AF STN AGRA
2024_MES_640483_1
80023-34/E8
Open Tender
Civil Works
Lump-sum
270 days
GE (AF) Tech Area Agra
As per Tender documents
9 documents required · 9 mandatory
₹1,000
GE(AF) Tech Area, Agra
₹1.8 L
Yes
3 Jul 2024
2 Feb 2024
3 May 2024
2 Feb 2024
26 Apr 2024
12 Apr 2024
Amount
SCHEDULE A PART I (A)(BUILDING WORKS) TO BE QUOTED BY THE TENDERER IN BOQ
Lump sum price worked out by the contractor for "BUILDING WORKS " as SHOWN IN listed in Sch 'A' Part -I (A) with permanent specifiction complete all as specified & directed and shown in drawings.
SCHEDULE A PART I (B) (MISC RELATED WORKS) TO BE QUOTED BY THE TENDERER IN BOQ
Work related to preparation of ground Toe wall and fitting, Pistol firing points, Target trench and Ricochet Pit, Fire Breaks complete all as specified, directed and shown in drawings. Lump sum price worked out by the contractor for 'MISC RELATED WORKS ' as listed in Sch 'A' Part -I (B)
SCHEDULE A PART II (INTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for 'INTERNAL WATER SUPPLY ' as listed in Sch 'A' Part -II
SCHEDULE A PART III (INTERNAL ELECTRIFICATION)
Lump sum price worked out by the contractor for ''INTERNAL ELECTRIFICATION)'' as listed in Sch 'A' Part -III
SCHEDULE A PART IV (ROAD/ PATH/ HARDSTNDING)
Lump sum price worked out by the contractor for ''ROAD/PATH/ CULVERTS / HARDSTNDING'' as listed in Sch 'A' Part -IV
SCHEDULE A PART V (EXTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for ''EXTERNAL WATER SUPPLY'' as listed in Sch 'A' Part -V
SCHEDULE A PART VI (EXTERNAL ELECTRIC SUPPLY)
Lump sum price worked out by the contractor for "EXTERNAL ELECTRIC SUPPLY'' as listed in Sch 'A' Part -VI
SCHEDULE A PART VII (SITE CLEARANCE, EXCAVATION & EARTHWORK)
Lump sum price worked out by the contractor for 'SITE CLEARANCE, EXCAVATION & EARTHWORK ' as listed in Sch 'A' Part -VII
SCHEDULE A PART VIII (SEWAGE DISPOSAL)
Lump sum price worked out by the contractor for "SEWAGE DISPOSAL'' as listed in Sch 'A' Part -VIII
SCHEDULE A PART IX (MISCELLANEOUS ITEMS OF B&R AND E&M) Note: To be quoted by the tenderer in BOQ .
Supply & Fixing flexible PVC waste pipe of 32 mm dia, 600 mm long complete all as specified and directed.
Supply & Fixing flexible PVC waste pipe of 40 mm dia, 600 mm long complete all as specified and directed.
Supply & Fixing gratings of 100mm dia made of stainless steel with waste hole complete all as specified and directed .
S&F 1.20 Mtr long street light bracket, made out of 32mm dia light grade GI pipe, bent to shape including fixing with GI flat and fixed to wall/ poles including all necessary nut/ bolts complete all as specified and directed.
M&L for brick masonary valve pit of size 90 cm x 90 cm x90 cm (internal of chamber ) depth of chember to be reckoned from the top of PCC in foundation to top the MS cover as 60 cm and including MS sheet cover fabricated from 3.15 mm thick MS sheet and frame of angle iron 50 mm x 50 mmx5 mm with fixing arrangement , hinges and locking arrangement and painting two coat of synethetic enamel paint over a coat of red oxide primer on MS cover and frame , inlcuding necessary excavation and earth work in any type of soil , returning , filling in approved soil disposal of surplus soil to a distance not exc.50 mtr , 150 mm thick PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation , brick work in cement motor (1:6) 15 mm thick plastering in cement mortoar (1:4) (both internally and externally) 100 mm thick PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in flooring complete all as directed suitable for upto 50mm dia.
M&L for cutting and taking out branch connection by in inserting tee 150x150x50mm for new connection all as specified and directed.
M&L for clean dry sand laid in trenches/ducts for bedding and cushioning to cable, including spreading and levelling complete all as specified and directed.
M&L for laying in trenches burnt brick sub class 'B' for cable protection laid adjacent to each other length wise perpendicular to the central axis of cablecomplete all as specified and directed.
Supply and only PVC insulated single core cable with copper conductor multi stranded of size 1.5 sq mm through inside of pole /GI pipe complete all as specified and directed.
Supply and fixing thermoplastic polystyrene/ polycarbonate cable termination enclosure, shock proof, vermin proof and dust proof complete with terminal for up to 3 phase cable of size 25 Sq mm/ 4 core and 01 No MCB SP 5 amps including non metalic clamps and GI nut bolts and washers of suitable size and fixed on pole /wall complete all as specified and directed.
Supply, install, test and commission LT feeder pillar box outdoor cubical type, 3 phase, 4 wire, 415 volts with 400 Amps Aluminium bus bar, IP 54, dust and vermin proof fabricated with CRCA sheet not less than 3.0 mm thick fixed on angle iron frame of size 50x50x6mm duly powder coated, front openable double door hinged with locking arrangements complete with and comprising the following including necessary PCC platform of suitable size to adjust to LT Panel complete all as specified and directed. (A)INCOMING:-(i) MCCB 4 pole,63 Amps with thermal and magnetic release, 50 Hz, 415 Volts, 25 KA -1 No (B)OUTGOINGS:-(i) MCCB 32 Amp 3 pole 415 volts thermal adjustable type 25 KA-02 Nos. .(ii) MCB SPN 40 Amps 230Volts 10KA-07 Nos. Note:(i) Cost of PCC platform 50mm thick 1:2:4 Type B-1 over 75mm thick sub base 1:5:10 type E-2 using 40mm graded stone aggregate is inclusive in the rate quoted for this item. (ii) Drawing of LT Panel shall be submitted by manufacturer will be approved by Accepting Officer before placing order.
Supply and Fixing the LED flood light fitting of IP-65 protection and 230 volts, 50 Hz of capacity 100 Watt connecting with three core flexible copper conductor of 1.5 Sqmm nominal area from light fitting to connector/junction box complete all as specified and directed.
Supply and Fixing the LED flood light fitting (Target illumination light) of IP-65 protection and 230 volts, 50 Hz of capacity 50 Watt connecting with three core flexible copper conductor of 1.5 Sqmm nominal area from light fitting to connector/junction box complete all as specified and directed..
Supply and Fixing the LED obstrction light fitting (Red light) of IP-65 protection and 230 volts, 50 Hz of capacity 50 Watt connecting with three core flexible copper conductor of 1.5 Sqmm nominal area from light fitting to connector/junction box complete all as specified and directed.
S & F of street light bracket arm fabricated out of 40 mm dia GI tubing light grade long bend to shape fixed to pole with 2 pair of suitable size clamps of fitted with suitable size nuts, bolts washers incl one coat of paint complete all as specified and directed.
Supply and fix energy saving & environmental friendly long life LED street light 70 watt made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection, impact resistance of IK07 & 10 KV external SPD and electronic driver of 70W LED 5700K complete all as specified and directed. Cat Part No. LHETBXU7PA7B070 of Make:- Havells or equivalent in the makes mentioned in PS complete all as specified and as directed.
Material and labour for cable joint termination junction syntex box PVC body housing of size 200x160x98 mm suitable for housing and including 100 amps rated aluminium bus bar, 3 phase, 4 wire system mounted on PVC insulators for one incomming and two out going cable entry space mounted on street light PCC/ tubular pole with 25x3 mm FI clamps with nut, bolts and washers and including one 6 to 10 amps MCB, SP, 240 volt for street light supply complete all as as directed . Make Sintex or equivalent.
Supply, installation, testiing commissioning and designing of 12.5 Mtr High Mast system, Mast Shaft shall be in two section, hot dip galvanised inside and outside in single dip, suitable for wind velocity as per IS 875 part 3 and Lantern carriage shall be of 40NB ERW class -B-MS pipe, diameter of lantern carriage ring of 600 mm internal dia, construction -12 arm welded, and provision for marking arrangement to include accesssories for high Mast including head frame, two point suspension system with steel wire rope of 6mm dia (7/19 construction ) double drum wrinch, galvanised lantern carriage arrengement suitable for 12 Nos luminaries LED types 150 watt,110 lux/watt, 5700K, symetrically and lightening final. The mast shall have an internal type power tool mounted at the base compartment for its operation, the system shall comprises complete all as specified and directed with following accessories and technical parameter. (a) Foundation bolts manufactured from special steel alongwith nuts, washer, anchor plates and templates. (b) Twin dome LED aviation light 20 Watt each - 1 Set. (c) Control panel housing suitable for control circuit including contactors, timers and suitable rating MCCBs/MCBs and 3 phase timer switch for automatic ON and OFF of the mast. It shall also have suitable control for operation of power tool. (d) Construction of suitable shallow foundation of size as specified by manufacturar with 'M' -20 concrete for the High Mast cosidering the safe soil bearing canpacity at site as 10 T/Sqm at minimum 2 Mtr depth with all materials and labours complete as per design given by highmast manufacturer including base foundation,nut bolts etc all as specified and directed.
(e) Material of construction - BSEN 10025 or equivalent. (f) 12 Nos luminaries LED types 150 watt warm white IP-66 symmetrically, symetrically and lightening final. Model No- BJFL150WLEDIWW or equivelant in CG/Bajaj/Philips (g) Cross section of mast 20 side polygon. (h) Length of Top section approx 8.250 mtr and bottom section 4.250 mtr. (j) Base diameter 360 mm (Approx) and Top Dia 150mm (Approx). (k) Joints shall be stress slip fit joints. (l) Length of overlap 1.5 times from the Dia of insertion. (m) Thickness of Galvanisation average 70 Microns. (n) Size of Door opening at base of Mast Should be not less than 1200mm x 250mm . (o) M.S. Base plate of size 540 mm dia and 25 mm thickness. (p) Dynamic loading as prevailing at site : - Max wind speed (IS-875-1987) - 180km/Hr, Nos of foundation bolts - 08 Nos of size as specified by manufacturer. (q) Method of operation - Motor and manual both. (r) Power tool shall be of integral type, minimum capacity of motor- 1.5 HP of single speed Reversible type 3 phase 415 volts. (s) The top of the mast is to be covered to aviod water logging inside the structure. (t) Note:- (i) Cost of equipment for loading/ unloading of high mast at site and erection is deemed to be included in above rate. (ii) Cost of earth work and PCC work is deemed to included in above rate and will be carried out as per manufacturer instructions. (iii) LED light and aviation light rate deemed including rate quoted in the above. (iv) Design and securing of housing for light tube done by contractor. Cost for same will be demeed to be inclusive of price quoted.
RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for for 50 users with upflow filter complete all as specified and shown on drawings.
Soakage, well excavation in ordinary soil, foundation in PCC 1:3:6, wells of honey combed and solid brick work in CM , RCC slab covers, filling with brick bats, complete of 3 M dia X 3.0 M effective depth.
Supply only approved earth from out side MD land for area development complete all as specified and as directed.
HARI BUILDERS
S R BUILDERS
Shiv Krishan Associates
YAUK ENGINEERS
Sethi Brothers
garg construction company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .