LT COL DHANU KUMAR RAI
GARRISON ENGINEER DAMAN TAT RAKSHAK VIHAR DALWADA NANI DAMAN POST DAMAN (UT) PIN 396210
REPAIR AND MAINTENANCE OF LT PANEL BOARDS, FEEDER PILLAR BOXES, APFC PANELS, U/G CABLES, EARTHING ETC AT ICGAS DAMAN
2022_MES_533502_1
8622/E8
Open Tender
Civil Works
Item Rate
330 days
ICGAS DAMAN
Class E Cat b(I)
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER DAMAN
₹20,000
11 Oct 2022
24 Jun 2022
23 Aug 2022
24 Jun 2022
20 Aug 2022
9 Jul 2022
Amount
M&L for prepartion of old paint with electrically operated spray machine surfaces of LT panel/feeder piller box of any type outdoor/indoor including removing old paint with scrubing and applying two coats of synthetic emanel paint of shade as per existing over a coat of red oxide primer, complete all as specified and directed.
Supply and fix in repair MCCB 63 Amps,16 KA,415 volts,FP,50 Hz complete all as specified and directed.
Supply and fix in repair MCCB 100 Amps,16 KA,415 volts,FP,50 Hz complete all as specified and directed.
Supply and fix in repair MCCB 160 Amps,25 KA,415 volts,FP,50 Hz complete all as specified and directed.
Supply and fix in repair MCCB 200 Amps,35 KA,415 volts,FP,50 Hz complete all as specified and directed.
Supply and fix in repair MCCB 250 Amps,35 KA,415 volts,FP,50 Hz complete all as specified and directed.
Supply and fix in repair MCB 63 Amps,10 KA,415 volts,FP,50 Hz complete all as specified and directed.
Supply and fix in repair MCB 40 Amps,10 KA,415 volts,FP,50 Hz complete all as specified and directed. Make for I No 2 to 8 :-Schneider/HPL/Legrand/Standard.
Supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz indoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 3.15 mm thick CRCA sheet duly powder coated and shall be CPRI approved and as approved by GE. The Panel shall have front and rear opening,locking arrangement, cable alleys, bus bar chamber and switch gear compartment ,hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate,aluminium bus bar duly covered with heat shrink sleeves colour coaded duly fixed on DMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length,incoming and outgoing MCCBs shall have extended bus bar links and mounted on 50x50x5mm size MS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate ) in foundation design subject to approved of GE to sent the site requirement complete all as specified and directed including comprising of following :- (a) MCCB 400 Amps,FP,36 KA,415 volts,50Hz-1 Nos (Incomer) (b) MCCB 100 Amps,TP,27 KA,415 volts,50Hz-4 Nos . (c) MCCB 63 Amps,TP,27 KA,415 volts,50Hz-4 Nos. (d) Digital voltmeter,with VSS -01 set,Digital, Ammeter,with CTs & ASS-01 set. (e) LED phase indication lamps RYB-01 set. (f) Aluminium bus bar TPN 600 Amps rating -01 set
supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz indoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick CRCA sheet duly powder coated and shall be CPRI approved and as approved by GE. The Panel shall have front and rear opening,locking arrangement, cable alleys, bus bar chamber and switch gear compartment ,hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate,aluminium bus bar duly covered with heat shrink sleeves colour coaded duly fixed on DMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length,incoming and outgoing MCCBs shall have extended bus bar links and mounted on 50x50x5mm size MS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate ) in foundation design subject to approved of GE to sent the site requirement complete all as specified and directed including comprising of following :- (a) MCCB 250 Amps,FP, 36 KA,415 volts,50Hz-1 No. (b) MCCB 100 Amps,TP, 27 KA,415 volts,50Hz-2 No. (c) MCCB 63 Amps,TP,27 KA,415 volts,50Hz-3 Nos. (d) Digital voltmeter,with VSS , Digital, Ammeter,with CTs & ASS-01 set. (e) LED phase indication lamps RYB-01 set. (f) Aluminium bus bar TPN 400 Amps rating -01 set
Taking out existing underground defective cable of any type and size from the trenches and from any other locations (including taking out of cable covers, pipes etc) complete all as directed.
Supply, laying in trenches/ducts/along wall/through pipes etc, testing and commissioning LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 240 sqmm,3.5 core including making cable connections by providing necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers etc complete in all respects, as specified and directed. Note for item No 2 to 3 :- (i) Excavation & Earth work,sand cushioning, cable cover and protection pipe shall be measured and paid separately. (ii) The cable shall be in one length unless otherwise directed by the GE. (iii) Make for item No 12 to 13 :- Havells/polycab/KEI/Finolex ISI Marked
Supply,lay and testing LT cable XLPE insulated, galvanised steel strip armoured,1100 volts grade with multistranded aluminium conductor of cross-sectional area 16 sqmm; 4 core laid in trenches/pipes/ducts/walls and connection with necessary cable lugs and glands, nuts, bolts and washers etc and testing including removing old unserviceable item complete all as specified and directed.
Supply and lay GI pipe 50mm dia light grade in any length with all GI fittings such as socket, elbow, bend, union, Tee etc laid in trenches/duct/culvert/road crossing etc for protection of cables including removing old unserviceable item complete all as specified and directed. Make :- Jindal/Tata/BST
Material and labour for GI pipe 80 mm dia"light grade " complete with all fittings laid in trenches,road/culvert crossing,on wall, floors,on roof,on pole, for cable protection complete all as specified and directed . Make :- Jindal/Tata/BST
Material and labour for PCC 1:3:6 type C1 using 20 mm graded coarse stone aggregate for platform, mass concrete and coping including form work all as specified and directed.
Supply and filling in and spreading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and as directed. Note: Punned thickess i.e 18 cm shall be measured for paymeny purpose.
Supply and laying unreinforced precast factory made concrete cable cover, class LV, Type -I, flat, size 250mm x 150mm x 40mm, complete all as specified and directed.
Excavation in trenches , not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft loose soil complete all as specified and directed.
Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed
Removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed
Material and labour in repairs for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6.3 mm thick buried directly in ground vertically (earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron strip of size 25 x 4 mm from earth electrode to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate no 3 of SSR Part-I provision of G I Pipe 40mm bore eight grade for protection of GI strip and GI watering pipe of 20 mm bore medium grade,GI funnel with wire mesh,including char-coal, salt packed all around the earth electrode plate in layers,PCC earth pit chamber 1:3:6 type C1,RCC cover 1:2:4 type B1,excavation,earth work in any strata and returning filling, removal of surplus soil and testing for required value, complete all as specified and directed.
Material and labour in repairs for synthetic insulating mat of size 2 mtr x 1mtr x19 mm thick complete all as specified and directed
Material and labour for fault finding of LT cables of size 70 to 240 sqmm X 3.5 core and any length with fault detective machine by thumbing method and suitable voltage and all as per manufactures instructions including providing straight through joint and additional cable of same existing size suitable to site requirement complete all as specified and directed.
Supply & fixing in repairs LED phase indicating lamp R Y B colour as required at site in existing panel boards complete all as specified and directed. Make :- Schneider/HPL/Legrand/Standard
Saviour Security Systems
Radha Engineering Services
Shree Ayyappa Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .